首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 312 毫秒
1.
Matrix‐assisted laser desorption/ionization time‐of‐flight mass spectrometry (MALDI‐TOF MS) has emerged as a promising tool to rapidly characterize Staphylococcus aureus. Different protocols have been employed, but effects of experimental factors, such as culture condition and sample preparation, on spectrum quality and reproducibility have not been rigorously examined. We applied MALDI‐TOF MS to characterize a model system consisting of five methicillin‐sensitive (MSSA) and five methicillin‐resistant S. aureus isolates (MRSA) under two culture conditions (agar and broth) and using two sample preparation methods [intact cell method and protein extraction method (PEM)]. The effects of these treatments on spectrum quality and reproducibility were quantified. PEM facilitated increases in the number of peaks and mass range width. Broth cultures further improved spectrum quality in terms of increasing the number of peaks. In addition, PEM increased reproducibility in samples prepared using identical culture conditions. MALDI imaging data suggested that the improvement in reproducibility may result from a more homogeneous distribution of sample associated with the broth/PEM treatment. Broth/PEM treatment also yielded the highest rate (96%) of correct classification for MRSA. Taken together, these results suggest that broth/PEM maximizes the performance of MALDI‐TOF MS to characterize S. aureus.

Significance and Impact of the Study

Two culture conditions (agar or broth) and two sample preparation methods (intact cell or protein extraction) were evaluated for their effects on profiling of Staphylococcus aureus using matrix‐assisted laser desorption/ionization time‐of‐flight mass spectrometry (MALDI‐TOF MS). Results indicated that MALDI‐enabled profiling of S. aureus is most effective when cultures are grown in broth and processed using a protein extraction‐based approach. These findings should enhance future efforts to maximize the performance of this approach to characterize strains of S. aureus.  相似文献   

2.
When studying the set of biologically active peptides (the so‐called peptidome) of a cell type, organ, or entire organism, the identification of peptides is mostly attempted by MS. However, identification rates are often dismally unsatisfactory. A great deal of failed or missed identifications may be attributable to the wealth of modifications on peptides, some of which may originate from in vivo post‐translational processes to activate the molecule, whereas others could be introduced during the tissue preparation procedures. Preliminary knowledge of the modification profile of specific peptidome samples would greatly improve identification rates. To this end we developed an approach that performs clustering of mass spectra in a way that allows us to group spectra having similar peak patterns over significant segments. Comparing members of one spectral group enables us to assess the modifications (expressed as mass shifts in Dalton) present in a peptidome sample. The clustering algorithm in this study is called Bonanza, and it was applied to MALDI‐TOF/TOF MS spectra from the mouse. Peptide identification rates went up from 17 to 36% for 278 spectra obtained from the pancreatic islets and from 21 to 43% for 163 pituitary spectra. Spectral clustering with subsequent advanced database search may result in the discovery of new biologically active peptides and modifications thereof, as shown by this report indeed.  相似文献   

3.
Emerging methods based on mass spectrometry (MS) can be used in the rapid identification of microorganisms. Thus far, these practical and rapidly evolving methods have mainly been applied to characterize prokaryotes. We applied matrix‐assisted laser‐desorption‐ionization‐time‐of‐flight mass spectrometry MALDI‐TOF MS in the analysis of whole cells of 18 N. fowleri isolates belonging to three genotypes. Fourteen originated from the cerebrospinal fluid or brain tissue of primary amoebic meningoencephalitis patients and four originated from water samples of hot springs, rivers, lakes or municipal water supplies. Whole Naegleria trophozoites grown in axenic cultures were washed and mixed with MALDI matrix. Mass spectra were acquired with a 4700 TOF‐TOF instrument. MALDI‐TOF MS yielded consistent patterns for all isolates examined. Using a combination of novel data processing methods for visual peak comparison, statistical analysis and proteomics database searching we were able to detect several biomarkers that can differentiate all species and isolates studied, along with common biomarkers for all N. fowleri isolates. Naegleria fowleri could be easily separated from other species within the genus Naegleria. A number of peaks detected were tentatively identified. MALDI‐TOF MS fingerprinting is a rapid, reproducible, high‐throughput alternative method for identifying Naegleria isolates. This method has potential for studying eukaryotic agents.  相似文献   

4.
This study aimed to identify novel serum peptides biomarkers for female breast cancer (BC) patients. We analyzed the serum proteomic profiling of 247 serum samples from 96 BC patients, 48 additional paired pre‐ and postoperative BC patients, 39 fibroadenoma patients as benign disease controls, and 64 healthy controls, using magnetic‐bead‐based separation followed by MALDI‐TOF MS. ClinProTools software identified 78 m/z peaks that differed among all analyzed groups, ten peaks were significantly different (P < 0.0001), with Peaks 1–6 upregulated and Peaks 7–10 downregulated in BC. Moreover, three peaks of ten (Peak 1, m/z: 2660.11; Peak 2, m/z: 1061.09; Peak 10, m/z: 1041.25) showed a tendency to return to healthy control values after surgery. And these three peptide biomarkers were identified as FGA605‐629, ITIH4 347–356, and APOA2 43–52. Methods used in this study could generate serum peptidome profiles of BC, and provide a new approach to identify potential biomarkers for diagnosis as well as prognosis of this malignancy.  相似文献   

5.
The peptide‐based quantitation accuracy and precision of LC‐ESI (QSTAR Elite) and LC‐MALDI (4800 MALDI TOF/TOF) were compared by analyzing identical Escherichia coli tryptic digests containing iTRAQ‐labeled peptides of defined abundances (1:1, 2.5:1, 5:1, and 10:1). Only 51.4% of QSTAR spectra were used for quantitation by ProteinPilot Software versus 66.7% of LC‐MALDI spectra. The average protein sequence coverages for LC‐ESI and LC‐MALDI were 24.0 and 18.2% (14.9 and 8.4 peptides per protein), respectively. The iTRAQ‐based expression ratios determined by ProteinPilot from the 57 467 ESI‐MS/MS and 26 085 MALDI‐MS/MS spectra were analyzed for measurement accuracy and reproducibility. When the relative abundances of peptides within a sample were increased from 1:1 to 10:1, the mean ratios calculated on both instruments differed by only 0.7–6.7% between platforms. In the 10:1 experiment, up to 64.7% of iTRAQ ratios from LC‐ESI MS/MS spectra failed S/N thresholds and were excluded from quantitation, while only 0.1% of the equivalent LC‐MALDI iTRAQ ratios were rejected. Re‐analysis of an archived LC‐MALDI sample set stored for 5 months generated 3715 MS/MS spectra for quantitation, compared with 3845 acquired originally, and the average ratios differed by only 3.1%. Overall, MS/MS‐based peptide quantitation performance of offline LC‐MALDI was comparable with on‐line LC‐ESI, which required threefold less time. However, offline LC‐MALDI allows the re‐analysis of archived HPLC‐separated samples.  相似文献   

6.
Matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry (MS) has been recently used to identify disease markers by directly profiling and quantifying the peptide/proteins in biological samples under different physiological or experimental conditions. The information of reproducibility of such quantitative profiling method has not been available. It is important to evaluate and reduce error from technical variation. In this study, an unbiased signal acquisition strategy was used to evaluate the effects of three sample-matrix spotting methods and two matrix chemicals, α-cyano-4-hydroxycinnamic acid (CHCA) and sinapinic acid, on the reproducibility of the peptide/protein signal intensities. The sandwich spotting method using 0.1% nitrocellulose coating film and CHCA gave the best quantitative results for the standard peptides and proteins with mass<66.5 kDa. The normalized signal intensities of the standard peptides and proteins were directly proportional to their concentrations with intra-assay (within-day) coefficient of variations (CVs) ranging from 6.5% to 17%. When analyzing serum peptides <6000 m/z, the interassay (between-days) CVs of all the evaluated peptide peaks were <15%. These data indicate that with the right MS analysis conditions, MALDI-TOF MS appears to be a feasible tool for directly profiling and quantifying the peptide/ proteins in biological samples.  相似文献   

7.
A comparative analysis of MALDI TOF mass spectra of low-molecular products resulting from the hydrolysis of native collagen I by collagenases of various classes (bacterial metallocollagenase from Clostridium histolyticum, serine collagenase from the Morikrasa commercial preparation, cysteine collagenase from Serratia proteomaculans, and cysteine collagenases from larvae of beetles Dermestesfrischi and D. maculates) was carried out. The spectra contain a number of ion peaks common for all collagenases; nevertheless, the mass spectra of each hydrolysate contains a unique set of peaks ("fingerprint") characteristic of each enzyme. This is especially true for the peaks of major products with relative intensities of more than 50%. At the same time, the enzymes of one class (cysteine collagenases) exhibit in their mass spectra peaks of identical major products. The results show a potential opportunity for MALDI TOF application in the primary screening of collagenases according to the fingerprints of collagen hydrolysis products.  相似文献   

8.
One of the challenges of current proteomics research is identifying healthy and diseased mass spectrometric (MS) patterns within biological fluids. As a result, sample preparation methodologies, as well as the mathematical tools utilized for MS data analysis become pivotal. This study involves a thorough evaluation of the reproducibility and protein resolution that various urinary protein preparation methodologies provide in MALDI MS analysis. Several precipitation approaches, ultrafiltration, as well as direct dilution of urine in MALDI MS compatible buffers were applied in combination to a thorough bioinformatics analysis of the generated MS data. Our results indicate that ultrafiltration, as well as direct dilution of urine in TFA, can provide information rich and reproducible spectra for mass ranges up to 20 kDa. The importance of the presence of peak reproducibility filters when generating disease classification models is suggested.  相似文献   

9.
Herein we report the use of mesoporous aluminosilicate (MPAS) for the simultaneous extraction of peptides and lipids from complex body fluids such as human plasma and synovial fluid. We show that MPAS particles, given their mesostructural features with nanometric pore size and high surface area, are an efficient device for simultaneous extraction of peptidome and lipidome from as little as a few microliters of body fluids. The peptides and the lipids, selected and enriched by MPAS particles and rapidly visualized by MALDI‐TOF MS, could form part of a diagnostic profile of the “peptidome” and the “lipidome” of healthy versus diseased subjects in comparative studies. The ability of this approach to rapidly reveal the overall pattern of changes in both lipidome and peptidome signatures of complex biofluids could be of valuable interest for handling large numbers of samples required in ‐omics studies for the purpose of finding novel biomarkers.  相似文献   

10.
The quality of MALDI‐TOF mass spectrometric analysis is highly dependent on the matrix and its deposition strategy. Although different matrix‐deposition methods have specific advantages, one major problem in the field of proteomics, particularly with respect to quantitation, is reproducibility between users or laboratories. Compounding this is the varying crystal homogeneity of matrices depending on the deposition strategy used. Here, we describe a novel optimised matrix‐deposition strategy for LC‐MALDI‐TOF/TOF MS using an automated instrument that produces a nebulised matrix “mist” under controlled atmospheric conditions. Comparisons of this with previously reported strategies showed the method to be advantageous for the atypical matrix, 2,5‐DHB, and improved phosphopeptide ionisation when compared with deposition strategies for CHCA. This optimised DHB matrix‐deposition strategy with LC‐MALDI‐TOF/TOF MS, termed EZYprep LC, was subsequently optimised for phosphoproteome analysis and compared to LC‐ESI‐IT‐MS and a previously reported approach for phosphotyrosine identification and characterisation. These methods were used to map phosphorylation on epidermal growth factor‐stimulated epidermal growth factor receptor to gauge the sensitivity of the proposed method. EZYprep DHB LC‐MALDI‐TOF/TOF MS was able to identify more phosphopeptides and characterise more phosphorylation sites than the other two proteomic strategies, thus proving to be a sensitive approach for phosphoproteome analysis.  相似文献   

11.
Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI–TOF MS) has been used to discriminate moniliaceous fungal species; however, darkly pigmented fungi yield poor fingerprint mass spectra that contain few peaks of low relative abundance. In this study, the effect of dark fungal pigments on the observed MALDI mass spectra was investigated. Peptide and protein samples containing varying concentrations of synthetic melanin or fungal pigments extracted from Aspergillus niger were analyzed by MALDI–TOF and MALDI–qTOF (quadrupole TOF) MS. Signal suppression was observed in samples containing greater than 250 ng/μl pigment. Microscopic examination of the MALDI sample deposit was usually heterogeneous, with regions of high pigment concentration appearing as black. Acquisition of MALDI mass spectra from these darkly pigmented regions of the sample deposit yielded poor or no [M+H]+ ion signal. In contrast, nonpigmented regions within the sample deposit and hyphal negative control extracts of A. niger were not inhibited. This study demonstrated that dark fungal pigments inhibited the desorption/ionization process during MALDI–MS; however, these fungi may be successfully analyzed by MALDI–TOF MS when culture methods that suppress pigment expression are used. The addition of tricyclazole to the fungal growth media blocks fungal melanin synthesis and results in less melanized fungi that may be analyzed by MALDI–TOF MS.  相似文献   

12.
Matrix‐assisted laser desorption/ionization time‐of‐flight intact cell mass spectrometry (MALDI‐TOF ICMS) is coming of age for the identification and characterization of fungi. The procedure has been used extensively with bacteria. UV‐absorbing matrices function as energy mediators that transfer the absorbed photoenergy from an irradiation source to the surrounding sample molecules, resulting in minimum fragmentation. A surprisingly high number of fungal groups have been studied: (i) the terverticillate penicillia, (ii) aflatoxigenic, black and other aspergilli, (iii) Fusarium, (iv) Trichoderma, (iv) wood rotting fungi (e.g. Serpula lacrymans) and (v) dermatophytes. The technique has been suggested for optimizing quality control of fungal Chinese medicines (e.g. Cordyceps). MALDI‐TOF ICMS offers advantages over PCR. The method is now used in taxonomic assessments (e.g. Trichoderma) as distinct from only strain characterization. Low and high molecular mass natural products (e.g. peptaibols) can be analysed. The procedure is rapid and requires minimal pretreatment. However, issues of reproducibility need to be addressed further in terms of strains of species tested and between run variability. More studies into the capabilities of MALDI‐TOF ICMS to identify fungi are required.  相似文献   

13.
Yin BC  Li H  Ye BC 《Analytical biochemistry》2008,383(2):270-278
DNA microarray technology has become powerful and popular in mutation/single nucleotide polymorphism (SNP) discovery and genotyping. However, this method is often associated with considerable signal noise of nonbiological origin that may compromise the data quality and interpretation. To achieve a high degree of reliability, accuracy, and sensitivity in data analysis, an effective normalization method to minimize the technical variability is highly desired. In the current study, a simple and robust normalization method is described. The method is based on introduction of a reference probe coimmobilized with SNP probes on the microarray for a dual-probe hybridization (DPH) reaction. The reference probe is used as an intraspot control for the customized microarrays. Using this method, the interassay coefficient of variation (CV) was reduced significantly by approximately 10%. After DPH normalization, the CVs and ranges of the ratios were reduced by two to five times. The relative magnitudes of variation of different sources were also analyzed by analysis of variance. Glass slides were shown to contribute the most to the variance, whereas sampling and residual errors had relatively modest contribution. The results showed that this DPH-based spot-dependent normalization method is an effective solution for reducing experimental variation associated with microarray genotyping data.  相似文献   

14.
The MALDI‐TOF MS has already been a main platform for phosphoproteome analysis. However, there are some weaknesses in direct analysis of endogenous phosphopeptides by MALDI‐TOF MS because of the serious suppression effect and poor ionization efficiency, which is brought by the excess of nonphosphopeptides and protein. It is essential to enrich endogenous phosphopeptides from complex biosamples efficiently prior to MALDI‐TOF MS analysis. Herein, we present a time‐saving and detailed protocol for the synthesis of titanium(iv)‐immobilized magnetic mesoporous silica nanoparticles (denoted as Fe3O4@mSiO2‐Ti4+), the subsequent enrichment process, and MALDI‐TOF MS analysis. We tested the LOD, size‐exclusive effect, reproducibility, and stability of Fe3O4@mSiO2‐Ti4+ nanoparticles. Furthermore, the ability of this protocol for identifying endogenous phosphopeptides in healthy human serum and saliva was investigated.  相似文献   

15.
We designed a new cross‐linker bearing a CHCA moiety. The use of the CHCA‐tagged cross‐linker JMV 3378 in conjunction with a neutral MALDI matrix α‐cyano‐4‐hydroxycinnamic methyl ester enabled specific signal enhancement in MALDI‐TOF MS of cross‐link containing peptides. Discrimination between modified and non‐modified peptides can be achieved by comparison of two spectra, one using CHCA and the other using the α‐cyano‐4‐hydroxycinnamic methyl ester matrix. The methodology was validated using cytochrome c and apo‐myoglobine as model proteins.  相似文献   

16.
A comparative analysis of MALDI TOF mass spectra of low-molecular products resulting from the hydrolysis of native collagen I by collagenases of various classes (bacterial metallocollagenase from Clostridium histolyticum, serine collagenase from the Morikrasa commercial preparation, cysteine collagenase from Serratia proteomaculans, and cysteine collagenases from larvae of beetles Dermestes frischi and D. maculatus) was carried out. The spectra contain a number of ion peaks common for all collagenases; nevertheless, the mass spectra of each hydrolysate contains a unique set of peaks (“fingerprint”) characteristic of each enzyme. This is especially true for the peaks of major products with relative intensities of more than 50%. At the same time, the enzymes of one class (cysteine collagenases) exhibit in their mass spectra peaks of identical major products. The results show a potential opportunity for MALDI TOF application in the primary screening of collagenases according to the fingerprints of collagen hydrolysis products.  相似文献   

17.
Proteomic profiling by MALDI‐TOF MS presents various advantages (speed of analysis, ease of use, relatively low cost, sensitivity, tolerance against detergents and contaminants, and possibility of automation) and is being currently used in many applications (e.g. peptide/protein identification and quantification, biomarker discovery, and imaging MS). Earlier studies by many groups indicated that moderate reproducibility in relative peptide quantification is a major limitation of MALDI‐TOF MS. In the present work, we examined and demonstrate a clear effect, in cases apparently random, of sample dilution in complex samples (urine) on the relative quantification of peptides by MALDI‐TOF MS. Results indicate that in urine relative abundance of peptides cannot be assessed with confidence based on a single MALDI‐TOF MS spectrum. To account for this issue, we developed and propose a novel method of determining the relative abundance of peptides, taking into account that peptides have individual linear quantification ranges in relation to sample dilution. We developed an algorithm that calculates the range of dilutions at which each peptide responds in a linear manner and normalizes the received peptide intensity values accordingly. This concept was successfully applied to a set of urine samples from patients diagnosed with diabetes presenting normoalbuminuria (controls) and macroalbuminuria (cases).  相似文献   

18.
Arthropod‐borne diseases are important causes of morbidity and mortality. The identification of vector species relies mainly on morphological features and/or molecular biology tools. The first method requires specific technical skills and may result in misidentifications, and the second method is time‐consuming and expensive. The aim of the present study is to assess the usefulness and accuracy of matrix‐assisted laser desorption/ionization time‐of‐flight mass spectrometry (MALDI‐TOF MS) as a supplementary tool with which to identify mosquito vector species and to invest in the creation of an international database. A total of 89 specimens belonging to 10 mosquito species were selected for the extraction of proteins from legs and for the establishment of a reference database. A blind test with 123 mosquitoes was performed to validate the MS method. Results showed that: (a) the spectra obtained in the study with a given species differed from the spectra of the same species collected in another country, which highlights the need for an international database; (b) MALDI‐TOF MS is an accurate method for the rapid identification of mosquito species that are referenced in a database; (c) MALDI‐TOF MS allows the separation of groups or complex species, and (d) laboratory specimens undergo a loss of proteins compared with those isolated in the field. In conclusion, MALDI‐TOF MS is a useful supplementary tool for mosquito identification and can help inform vector control.  相似文献   

19.
The identification of new diagnostic or prognostic biomarkers is one of the main aims of clinical cancer research. In recent years, there has been a growing interest in using mass spectrometry for the detection of such biomarkers. The MS signal resulting from MALDI‐TOF measurements is contaminated by different sources of technical variations that can be removed by a prior pre‐processing step. In particular, denoising makes it possible to remove the random noise contained in the signal. Wavelet methodology associated with thresholding is usually used for this purpose. In this study, we adapted two multivariate denoising methods that combine wavelets and PCA to MS data. The objective was to obtain better denoising of the data so as to extract the meaningful proteomic biological information from the raw spectra and reach meaningful clinical conclusions. The proposed methods were evaluated and compared with the classical soft thresholding denoising method using both real and simulated data sets. It was shown that taking into account common structures of the signals by adding a dimension reduction step on approximation coefficients through PCA provided more effective denoising when combined with soft thresholding on detail coefficients.  相似文献   

20.

Background

Most studies of microRNA (miRNA) and disease have examined tissue-specific expression in limited numbers of samples. The presence of circulating miRNAs in plasma samples provides the opportunity to examine prospective associations between miRNA expression and disease in initially healthy individuals. However, little data exist on the reproducibility of miRNAs in stored plasma.

Methods

We used Real-Time PCR to measure 61 pre-selected microRNA candidates in stored plasma. Coefficients of variation (CVs) were used to assess inter-assay reliability (n = 15) and within-person stability over one year (n = 80). Intraclass correlation coefficients (ICCs) and polychoric correlation coefficients were used to assess within-person stability and delayed processing reproducibility (whole blood stored at 4°C for 0, 24 and 48 hours; n = 12 samples).

Results

Of 61 selected miRNAs, 23 were detected in at least 50% of samples and had average CVs below 20% for inter-assay reproducibility and 31 for delayed processing reproducibility. Ten miRNAs were detected in at least 50% of samples, had average CVs below 20% and had ICCs above 0.4 for within-person stability over 1–2 years, six of which satisfied criteria for both interassay reproducibility and short-term within-person stability (miR-17-5p, -191-5p, -26a-5p, -27b-3p, -320a, and -375) and two all three types of reproducibility (miR-27b-3p and -26a-5p). However, many miRNAs with acceptable average CVs had high maximum CVs, most had low expression levels, and several had low ICCs with delayed processing.

Conclusions

About a tenth of miRNAs plausibly related to chronic disease were reliably detected in stored samples of healthy adults.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号