首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
We have constructed a reagentless lactate sensor using lactate oxidase (LOD) covalently attached to an electropolymerized copolymer film, poly(5-hydroxy-1,4-naphthoquinone-co-5-hydroxy-3-thioacetic acid-1,4-naphthoquinone), poly(JUG-co-JUGA). Around 10(-12)Mcm(-2) of covalently bound enzymes are immobilized on these films. In aerated medium, the amperometric response versus lactate concentration shows a sensitivity of 350 +/- 50 microAM(-1)cm(-2) for an applied potential of +0.5V versus Ag|AgCl on a film-coated Pt electrode. In deaerated medium, the quinone group, conjugated with the polymer backbone, acts as an immobilized mediator. An amperometric response is observed on film-coated glassy carbon (GC) electrode at a potential as low as -0.1V versus Ag|AgCl, with a sensitivity of 110 +/- 40 microAM(-1)cm(-2).  相似文献   

2.
Gold nanotubular electrode ensembles were prepared by using electroless deposition of the metal within the pores of polycarbonate track-etched membranes. Mono-enzyme (GOx) and monolayer/bilayer bienzyme (GOx/HRP) bioelectrodes were prepared by immobilizing the enzymes onto gold nanotubes surfaces modified with mercaptoethylamine. Batch amperometric responses to glucose for the different bioelectrodes were determined and compared. The response of the two geometries (monolayer and bilayer) of the bienzyme electrodes was shown to vary with regard to sensitivity at detection potentials above 0V. On the contrary, at detection potentials below 0V, no noticeable influence of the configuration of the bienzyme on the response intensity was observed. The mono-enzyme (650 microAmM-1 in benzoquinone (BQ) at -0.8 V versus Ag/AgCl) and the two bienzyme bioelectrodes (+/-400 microAmM-1 in hydroquinone (H2Q) at -0.2V versus Ag/AgCl) display remarkable sensitivities compared to a classical GOx-modified gold macroelectrode (13 microAmM-1 in BQ at -0.8 V versus Ag/AgCl). A remarkable feature of the bienzyme electrodes is the possibility to detect glucose at very low applied potentials where the noise level and interferences from other electro-oxidizable compounds are minimal. Another important characteristic of the monolayer bienzyme electrode is the possible existence of a direct electronic communication between HRP and the transducer surface.  相似文献   

3.
We have developed a new method for forming titanium-nitride(TiN)-coated plates using radio-frequency arc spraying (RFAS). A TiN coating formed by RFAS has been used for electrochemical prevention of marine biofouling. X-ray diffraction and X-ray photoelectron spectroscopy indicate that a TiN composite film containing Ti was formed on a polyethylene terephthalate plate surface when Ti was sprayed by RFAS under atmospheric pressure. A cyclic voltammogram (scan rate 20 mV/s) of the TiN formed by RFAS revealed no oxidative and reductive peak currents in the range −0.6 V to 1.2 V against a saturated silver/silver chloride (Ag/AgCl) electrode. When a potential of 1.0 V against Ag/AgCl was applied to the electrode in seawater, no dissolved Ti was detected. Changes in pH and the chlorine concentration were not observed in this range. In all, only 4.5% of the Vibrio alginolyticus cells attached to the electrode survived when a potential of 0.8 V against Ag/AgCl was applied in seawater for 30 min. In field experiments, attachment of the organisms to the TiN electrode was inhibited by applying an alternating potential of 1.0 V and −0.6 V against Ag/AgCl. The TiN film can be formed by RFAS on large and intricately shaped surfaces, and it is a practical electrode for the electrochemical prevention of fouling of various marine structures. Received: 17 April 1998 / Received revision: 5 June 1998 / Accepted: 19 June 1998  相似文献   

4.
Here, we report the development of an electrochemical detection method for endotoxin based on the Limulus amebocyte lysate (LAL) assay. A mixture of LAL reagent and endotoxin sample solution was incubated for 1 h. The endotoxin activated a cascade reaction of zymogens contained in the LAL to generate p-nitroaniline (pNA) which was then electrochemically detected by differential pulse voltammetry (DPV). The generated pNA gave a clear peak at -0.75 V vs. silver/silver chloride (Ag/AgCl), which increased with the concentration of endotoxin in the LAL assay solution. This DPV detection was performed using an electrode chip device fabricated from a diamond-like carbon-coated glass substrate. This chip device could detect as low as 10 endotoxin units l(-1) at room temperature within 1 h. This novel electrochemical method for the detection of endotoxin appears promising for the development of compact, low-cost and easy-to-use sensors for on-site monitoring of potentially contaminated medical supplies, including dialysis fluid, transplanted tissue and culture medium for assisted reproduction.  相似文献   

5.
A rapid and sensitive method is described for the measurement of picomole levels of the biological thiols glutathione, cysteine, penicillamine, cysteamine, and ergothioneine by a combination of high-performance liquid chromatography and electrochemical detection (ECD). The compounds were separated isocratically on a reversed-phase C18 column by ion-pair chromatography with a mobile phase containing 5 mM acetic acid and 2.5 mM sodium 1-octanesulfonate. After chromatographic separation, the eluate was combined with silver nitrate dissolved in ammonium nitrate buffer at pH 10.5. A platinum disc electrode was used at -0.1 V vs Ag/AgCl to detect the amount of silver ions that had been consumed by the reaction with thiols. For measurement of disulfide, S-sulfonation with sodium sulfite or electroreduction were used to cleave the disulfide, and the thiol anions produced were detected by HPLC-ECD as for the reduced forms. The method was used to assay thiols and disulfides in biological materials.  相似文献   

6.
A portable and cost-effective technique to measure the dimethyl ether (DME) concentrations has been developed. It is based on an electrochemical principle measuring the oxidation current of DME at an applied potential of +0.2V versus a Ag/AgCl reference electrode. Thick-film printing technique is used for the fabrication of this DME sensor, and platinum nanoparticles in the crystallite size of 5.5 nm are used for the modification of the working electrode surface. This modification enhances the sensor performance significantly leading to a higher sensitivity of the sensor comparing to bare platinum electrode. Evaluation and characterization of this sensor are carried out over the DME concentration range of 0-7% (v/v), and a linear relationship between sensor outputs and the DME concentrations with an average R(2) of 0.996 exists. The reproducibility of the sensor is also very good. This electrochemically based DME sensor fabricated by thick-film screen printing technique and using the platinum nanoparticles to enhance its performance will be valuable and practical for the estimation of the airway mucosal blood flow.  相似文献   

7.
Multi-walled carbon nanotubes (MWCNTs) were synthesized on platinum plate electrodes by the chemical vapor deposition (CVD) method. From the results of X-ray photoelectron spectroscopy and voltammetric investigation, the iron nanoparticles used as a catalyst for the MWCNT synthesis were enclosed with MWCNTs. The MWCNTs synthesized on the Pt plate (MWCNTs/Pt) electrode were immediately immersed into solutions of d-fructose dehydrogenase (FDH) to immobilize the enzyme onto the MWCNTs/Pt electrode surfaces. After the FDH was immobilized onto the MWCNTs/Pt electrode, a well-defined catalytic oxidation current based on FDH was observed from ca. -0.15V (versus Ag/AgCl/sat'd KCl), which was close to the redox potential of heme c as a prosthetic group of FDH. From an analysis of a plot of the catalytic current versus substrate, the calibration range for the fructose concentration was up to ca. 40mmoldm(-3), and the apparent Michaelis-Menten constant was evaluated to be 11+/-1mmoldm(-3).  相似文献   

8.
Polyethylene glycol-modified glucose oxidase (PEG-GOD) was prepared. Carbon paste (CP) containing PEG-GOD retained enzyme activity of 0·02 U cm−2. Anodic and cathodic peak currents of modified GOD in CP matrix were observed on the differential pulse voltammograms at the potential of −0·36 and −0·36 V vs. Ag/AgCl, respectively. The addition of glucose to a test solution brought about an increase in the anodic current on the PEG-GOD-based electrode at the potential as low as 0·0 V vs. Ag/AgCl. The current increase was proportional to the concentration of glucose up to 50 mM.  相似文献   

9.
Magnetic sector field inductively coupled plasma-mass spectrometry (ICP-MS) was applied to the reliable determination of the 8 essential trace elements cobalt (Co), chromium (Cr), copper (Cu), iron (Fe), manganese (Mn), nickel (Ni), selenium (Se), and vanadium (V) as well as the 7 nonessential and toxic elements silver (Ag), aluminum (Al), arsenic (As), gold (Au), platinum (Pt), scandium (Sc), and titanum (Ti) in 27 transitory and mature human milk samples and in 4 selected infant formulas. This advanced instrumentation can separate spectral overlaps from the analyte signal hampering significantly the determination of many trace elements by conventional ICP-MS. Moreover, superior detection limits in the picogram per liter range can be obtained with such magnetic sector field instruments. Therefore, this is the first study to report the concentrations of the elements Ag, Au, Pt, Sc, Ti, and V in human milk and in infant formulas. Concentrations of Ag (median: 0.41 μg/L; range: <0.13–42 μg/L) and Au (median: 0.29 μg/L; range 0.10–2.06 μg/L) showed large variations in human milk that might be associated with dental fillings and jewelry. Pt concentrations were very low with most of the samples below the method detection limit of 0.01 μg/L. Human milk concentrations of Co (median: 0.19 μg/L), Fe (380 μg/L), Mn (6.3 μg/L), Ni (0.79 μg/L), and Se (17 μg/L) were at the low end of the corresponding reference ranges. Concentrations of Cr (24.3 μg/L) in human milk were five times higher than the high end of the reference range. For Al (67 μg/L), As (6.7 μg/L), and V (0.18 μg/L), most of the samples had concentrations well within the reference ranges. All elemental concentrations in infant formulas (except for Cr) were approximately one order of magnitude higher than in human milk.  相似文献   

10.
A reliable and simple differential pulse polarographic method is described for the determination of thymoquinone in black seed oil. The polarographic behaviour of thymoquinone was examined in various buffer systems over the pH range 5.0-10.0. Thymoquinone is reduced in a single, reversible peak at the dropping mercury electrode. The differential pulse polarogram showed a distinct peak in S?rensen buffer:methanol (3:7, v/v; pH 8.5) at a peak potential of -0.095 V (vs. silver/silver chloride electrode), and a plot of peak height against concentration was found to be linear over the range 0.2-15.0 microg/mL (R = 0.9998). The limit of detection was calculated to be 0.054 microg/mL. The polarographic method has been applied to determine thymoquinone in two black seed oil preparations available on the Austrian pharmaceutical market.  相似文献   

11.
The dominant sugar in the body fluids of many insects is not glucose, the sugar of the vertebrates, but trehalose. In a step toward a cell that would operate in insects, we describe here a trehalose electrooxidizing anode. The novel component of the anode is its engineered, trehalose oxidation catalyzing, FAD-glucose-3-dehydrogenase (G3DH). Screening for gene-sources of G3DH pointed to the G3DH of Agrobacterium tumefaciens. Sequencing of the A. tumefaciens genome revealed a 1.7 kb fragment which contained the G3DH coding gene. The fragment was isolated, cloned and expressed in E. coli strain BL-21, to yield the approximately 65 kDa his-tagged flavoenzyme, with a specific activity of approximately 2.5U/mg protein. Electrical wiring of its reaction center to a carbon electrode through a high apparent electron diffusion coefficient (5.8 x 10(-6)cm(2)/s) redox hydrogel with a -0.2V versus Ag/AgCl redox potential resulted in the trehalose electrooxidizing anode. Trehalose was electrooxidized at pH 7.2 already at -0.36 V versus Ag/AgCl. At 0 V versus Ag/AgCl the trehalose electrooxidation current density was 0.1 mA/cm(2).  相似文献   

12.
A disposable and mediatorless immunosensor based on a conducting polymer (5,2':5'2"-terthiophene-3'-carboxylic acid) coated screen-printed carbon electrode has been developed using a separation-free homogeneous technique for the detection of rabbit IgG as a model analyte. Horseradish peroxidase (HRP) and streptavidin were covalently bonded with the polymer on the electrode and biotinylated antibody was immobilized on the electrode surface using avidin-biotin coupling. This sensor was based on the competitive assay between free and labeled antigen for the available binding sites of antibody. Glucose oxidase was used as a label and in the presence of glucose, H(2)O(2) formed by the analyte-enzyme conjugate was reduced by the enzyme channeling via HRP bonded on the electrode. The catalytic current was monitored amperometrically at -0.35 V vs. Ag/AgCl and this method showed a linear range of RIgG concentrations from 0.5 to 2 microg/ml with standard deviation +/-0.0145 (n=4). Detection limit was determined to be 0.33 microg/ml.  相似文献   

13.
This paper describes a new amperometric biosensor for glucose monitoring. The biosensor is based on the activity of glucose dehydrogenase (GDH) and diaphorase (DI) co-immobilized with NAD(+) into a carbon nanotube paste (CNTP) electrode modified with an osmium functionalized polymer. This mediator was demonstrated to shuttle the electron transfer between the immobilized diaphorase and the CNTP electrode, thus, showing a good electrocatalytic activity towards NADH oxidation at potentials around +0.2V versus Ag|AgCl, where interfering reactions are less prone to occur. The biosensor exhibits a detection limit of 10 micromol L(-1), linearity up to 8 x 10(-4) mol L(-1), a sensitivity of 13.4 microA cm(-2)mmol(-1)L(-1), a good reproducibility (R.S.D. 2.1%, n=6) and a stability of about 1 week when stored dry at 4 degrees C. Finally, the proposed biosensor was applied for the determination of glucose in different samples of sweet wine and validated with a commercial spectrophotometric enzymatic kit.  相似文献   

14.
A commercial lysine oxidase (LyOx) from Trichoderma viride was immobilized covalently onto gold nanoparticles (AuNPs) and platinum nanoparticles (PtNPs) electrodeposited onto Au electrode using 3-aminopropyltriethoxy silane (3-APTES) and glutaraldehyde cross linking chemistry. A lysine biosensor was fabricated using LyOx/3-APTES/AuNPs-PtNPs/Au electrode as a working electrode, Ag/AgCl (3 M KCl) as standard electrode and Pt wire as auxiliary electrode connected through a potentiostat. The enzyme electrode was characterized by scanning electron microscopy (SEM), Fourier transform infrared (FTIR) spectroscopy, electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV). The cumulative effect of AuNPs and PtNPs showed excellent electrocatalytic activity at low applied potential for detection of H2O2, a product of LyOx reaction. The sensor showed its optimum response within 4 s, when polarized at 0.2 V vs. Ag/AgCl in 0.1 M phosphate buffer, pH 7.5 at 30 °C. The linear range and detection limit of the sensor were 1.0–600 μM and 1.0 μM (S/N = 3), respectively. Biosensor measured lysine level in sera, milk and amino acid tablet, which correlated well with those by standard HPLC method. The enzyme electrode lost 50% of its initial activity after 200 uses over a period of 4 months.  相似文献   

15.
Laccase purified from Ganoderma sp. was immobilized covalently onto electrochemically deposited silver nanoparticles (AgNPs)/carboxylated multiwalled carbon nanotubes (cMWCNT)/polyaniline (PANI) layer on the surface of gold (Au) electrode. A polyphenol biosensor was fabricated using this enzyme electrode (laccase/AgNPs/cMWCNT/PANI/Au electrode) as the working electrode, Ag/AgCl as the reference electrode, and platinum (Pt) wire as the auxiliary electrode connected through a potentiostat. The biosensor showed optimal response at pH 5.5 (0.1 M acetate buffer) and 35 °C when operated at a scan rate of 50 mV s−1. Linear range, response time, and detection limit were 0.1–500 μM, 6 s, and 0.1 μM, respectively. The sensor was employed for the determination of total phenolic content in tea, alcoholic beverages, and pharmaceutical formulations. The enzyme electrode was used 200 times over a period of 4 months when stored at 4 °C. The biosensor has an advantage over earlier enzyme sensors in that it has no leakage of enzyme during reuse and is unaffected by the external environment due to the protective PANI microenvironment.  相似文献   

16.
ObjectivesThe study investigated effects of electrode material, inter-electrode distance (IED), and conductive gel on electromyographic (EMG) activity recorded from the masseter muscle.Materials and methodsEMG was recorded unilaterally, as ten volunteers performed standardized oral tasks. Ag/AgCl and Ag coated with Au were the gel-based; Ag alloy coated with graphene, pure Ag coated with graphene and silver nanowire embedded electrodes were the gel-free materials tested. Ag/AgCl electrodes were tested at three different IEDs (i.e. 15 mm, 20 mm, 25 mm). An electrode relative performance index (ERPI) was defined and calculated for each of the standardized oral tasks that the volunteers performed. ERPI values obtained for the different oral tasks with different electrode materials and IEDs were compared using two-way repeated-measures ANOVA.ResultsERPI values were not significantly influenced by IED. However, for the electrode materials statistically significant differences were found in ERPI values for all oral tasks. Of the gel-free electrode materials tested, pure silver electrodes coated with graphene had the highest ERPI values followed by Ag alloy electrodes coated with graphene and silver nanowire embedded electrodes.ConclusionsWithin the limitations of the study, IED between 15 and 25 mm has a negligible effect on masseter muscle EMG. Graphene coated and silver nanowire embedded electrodes show promise as gel-free alternatives.  相似文献   

17.
The optimal conditions to prepare water-soluble, stable poly(acrylic acid)-wrapped multiwalled carbon nanotubes (PAA-MWNTs) complex is presented. PAA-MWNTs shows high stability within weak acid to weak basic pH condition. The complex also shows good endurance to moderate ionic strengths in the buffer solution. The PAA-MWNTs complex film-covered electrode demonstrates stable, excellent electrocatalytic activity to oxidize NADH, which makes it possible to prepare NADH sensor at a low potential of approximately 0.13 V (versus Ag/AgCl) with the linear range of 4-100 microM by differential pulse voltammetry.  相似文献   

18.
In this work, adrenodoxin (Adx) was expressed on the outer membrane of E. coli by autodisplay and then the iron–sulfur cluster was incorporated into apo-Adx by an anaerobic reconstitution process. For the determination of the redox potentials of the iron–sulfur clusters of the autodisplayed Adx, E. coli cells with autodisplayed Adx were immobilized on a gold electrode modified with a self-assembled monolayer of mercaptoundecanoic acid (MUA). From the repeated cyclic voltammetry (CV) analysis, the E. coli (10 mM HEPES buffer, pH 7.0) with autodisplayed Adx showed significant changes in shape with an oxidation peak at + 0.4 V (vs. Ag/AgCl) and a reduction peak at − 0.3 V (vs. Ag/AgCl) after the reconstitution process for the incorporation of the iron–sulfur cluster. From the repeated CV analysis in the reduction and oxidation potential ranges, the iron–sulfur clusters of the autodisplayed Adx were observed to undergo reversible redox reactions via direct electron transfer to the MUA-modified gold electrode.  相似文献   

19.
A high-performance liquid chromatographic method for the determination of penicillamine in plasma, whole blood, and urine samples is described. The method uses a commercially available electrochemical detector at a potential of +0.1 V versus the Ag/AgCl reference electrode. This method is selective and sensitive for sulfhydryl compounds. The chromatography separates penicillamine from other endogenous sulfhydryl compounds with a limit of detection for penicillamine in biological samples of ca. 10−7M.  相似文献   

20.
The label-free amperometric detection of a rabbit IgG antigen by an anti-rabbit IgG antibody is achieved by observing the electrochemistry at a glassy carbon electrode modified with antibody entrapped in an electrodeposited polypyrrole membrane. In a flow injection apparatus the electrode is pulsed between -0.2 and +0.4 V versus Ag/AgCl. The pulsing of the electrode switches the polypyrrole membrane between the oxidised and reduced states. When antigen is injected into the flow stream a change in current is observed at the electrode despite the antigen or antibody being redox inactive at the potentials employed. It is proposed that this current is due to a change in the flux of ions into and out of the polypyrrole matrix during a pulse when the poly-anionic antigen is present. The immunoreaction was reversible because the 200 ms pulse at each potential was too short to allow secondary bonding forces (hydrogen bonding and hydrophobic forces) which are responsible for the strength of the antibody-antigen complex to be established. The consequence of the reversibility of the antigen-antibody binding is a low apparent affinity constant but an easily regenerated recognition interface.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号