首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The ability to simultaneously concentrate diverse microbes is an important consideration for sample collection methods that are used for emergency response and environmental monitoring when drinking water may be contaminated with an array of unknown microbes. This study focused on developing a concentration method using ultrafilters and different combinations of a chemical dispersant (sodium polyphosphate [NaPP]) and surfactants. Tap water samples were seeded with bacteriophage MS2, Escherichia coli, Enterococcus faecalis, Cryptosporidium parvum, 4.5-μm microspheres, Salmonella enterica serovar Typhimurium, Bacillus globigii endospores, and echovirus 1. Ten-liter tap water samples were concentrated to ~250 ml in 12 to 42 min, depending on the experimental condition. Initial experiments indicated that pretreating filters with fetal bovine serum or NaPP resulted in an increase in microbe recovery. The addition of NaPP to the tap water samples resulted in significantly higher microbe and microsphere recovery efficiencies. Backflushing of the ultrafilter was found to significantly improve recovery efficiencies. The effectiveness of backflushing was improved further with the addition of Tween 80 to the backflush solution. The ultrafiltration method developed in this study, incorporating the use of NaPP pretreatment and surfactant solution backflushing, was found to recover MS2, C. parvum, microspheres, and several bacterial species with mean recovery efficiencies of 70 to 93%. The mean recovery efficiency for echovirus 1 (49%) was the lowest of the microbes studied for this method. This research demonstrates that ultrafiltration can be effective for recovering diverse microbes simultaneously in tap water and that chemical dispersants and surfactants can be beneficial for improving microbial recovery using this technique.  相似文献   

2.
This study focused on ultrafiltration as a technique for simultaneously concentrating and recovering viruses, bacteria and parasites in 100-L drinking water samples. A chemical dispersant, sodium polyphosphate, and Tween 80 were used to increase microbial recovery efficiencies. Secondary concentration was performed to reduce sample volumes to 3-5 mL for analysis using tissue culture, microscopy, and real-time PCR and RT-PCR. At seeding levels of 100-1000 (CFU, PFU, oocysts, or particles), a "high-flux" ultrafiltration procedure was found to achieve mean recoveries of 51-94% of simultaneously seeded MS2 bacteriophage, echovirus 1, Salmonella enterica subsp. enterica serovar Typhimurium, Bacillus atrophaeus subsp. globigii endospores, Cryptosporidium parvum oocysts, and 4.5-mum microspheres. When 4-7% of the final sample concentrate volume was assayed using real-time PCR and RT-PCR, overall method sensitivities were <100 C. parvum oocysts, <240 PFU echovirus 1, <100 CFU Salmonella and approximately 160 CFU B. atrophaeus spores in 100-L drinking water samples. The "high-flux" ultrafiltration procedure required approximately 2 h, including time required for backflushing. Secondary concentration procedures required an additional 1-3 h, while nucleic acid extraction and real-time PCR procedures required an additional 2-2.5 h. Thus, this study demonstrated that efficient recovery and sensitive detection of diverse microbes in 100-L drinking water samples could be achieved within 5-8 h using ultrafiltration, rapid secondary processing techniques, and real-time PCR.  相似文献   

3.
4.
Dead-end ultrafiltration (DEUF) is an alternative approach to tangential-flow hollow-fiber ultrafiltration that can be readily employed under field conditions to recover microbes from water. The hydraulics of DEUF and microbe recovery for a new DEUF method were investigated using 100-liter tap water samples. Pressure, flow rate, and temperature were investigated using four hollow-fiber ultrafilter types. Based on hydraulic performance, the Asahi Kasei REXEED 25S ultrafilter was selected for microbe recovery experiments. Microbe recovery experiments were performed using MS2 bacteriophage, Enterococcus faecalis, Clostridium perfringens spores, and Cryptosporidium parvum oocysts. Microbes were recovered from ultrafilters by backflushing using a surfactant solution. Average flow rates were 2.1 liters/min for 100-liter water samples having turbidities of 0.28 to 4.3 nephelometric turbidity units (NTU), and no evidence of appreciable filter clogging was observed. The DEUF average recovery efficiencies for each study analyte in tap water were as follows: for E. faecalis, 93% ± 16%; for MS2, 57% ± 7.7%; for C. perfringens spores, 94% ± 22%; and for C. parvum, 87% ± 18%. Average microbe recoveries for tap water amended with surface water (average turbidity = 4.3 NTU) were as follows: for E. faecalis, 78% ± 12%; for MS2, 73% ± 13%; for C. perfringens, 57% ± 21%; and for C. parvum, 83% ± 21%. These data demonstrate that DEUF is an effective method for recovering diverse microbes from water and should be a useful tool for field-based environmental investigations.There are an estimated 4 million to 33 million cases of acute gastrointestinal illness each year in the United States due to drinking water (3, 11). From 2005 to 2006, 20 reports of waterborne disease and outbreaks (WBDOs) associated with drinking water were submitted to the national Waterborne Disease and Outbreak Surveillance System (19). In addition, a record number (78 reports) of WBDOs associated with recreational water were also submitted to the Waterborne Disease and Outbreak Surveillance System in 2005 and 2006 (20). Detecting the etiologic agents for WBDOs is challenging due to such factors as the time delay between case exposure and water sampling, microbial die-off, and water dilution or treatment prior to sampling. Because it is likely that pathogens will be present at low concentrations in water sampled for outbreak investigations, relatively large volumes of water (e.g., 40 to 100 liters) should be collected. In addition, sampling water for a diverse array of microbes is sometimes a goal when multiple etiologic agents are suspected for a WBDO (13) or during emergency responses when the contaminant has not been identified.Hollow-fiber ultrafiltration (UF) has been shown to be an effective technique for collecting large-volume water samples for recovery of diverse microbes, including viruses, vegetative bacteria, bacterial spores, and parasites (5, 6, 10, 12, 14). However, most hollow-fiber UF techniques utilize a tangential-flow approach that requires comprehensive operator training and which is generally not conducive to rapid-response implementation for field sampling. While the tangential-flow (i.e., recirculating flow) UF technique has been shown to be effective for microbe recovery, it is a more complicated sampling technique than traditional direct-filtration techniques, such as membrane filtration for coliforms (1), microfiltration for Cryptosporidium and Giardia (oo)cysts (18), and adsorption-elution microfiltration for viruses (4). For emergency response, outbreak investigations, or other field investigations performed by personnel with limited training in water sample collection, a dead-end UF (DEUF) technique would be useful for capturing and recovering multiple microbe classes.Relatively few studies have reported using hollow-fiber UF in a DEUF configuration. Kearns et al. (7) reported using an automated DEUF system to recover Bacillus atrophaeus spores from tap water, with reported recovery efficiencies of 23 to 40% in ∼100-liter samples with low-level seeding (330 to 1,000 CFU). These researchers performed filter backflushing using a phosphate buffer containing either Tween 20 or sodium polyphosphate. Kearns et al. also reported suspected ultrafilter fouling based on measured reductions in flow rates for ∼100-liter samples (7). The Kearns et al. observations indicate that the ultrafilter pore size and filter area are important hydraulic performance variables for the DEUF technique. Leskinen and Lim (9) reported using hollow-fiber DEUF for recovery of enterococci from 100-liter samples of beach water. These researchers used a urea-lysine solution to elute (instead of backflush) enterococci from ultrafilters. Leskinen and Lim reported a wide range of recovery efficiencies (4 to 708%; average = 251%) for their DEUF method but did not discuss whether water quality (other than a potential variability in microbe distribution in the 100-liter samples) could have contributed to ultrafilter fouling or variable method performance (9).The present study was designed to investigate DEUF using different commercially available hollow-fiber ultrafilters having a range of pore sizes and filter medium sizes. The parameters tested included the effect of the water sample flow rate and temperature on system pressure and the effect of turbidity on the permeate flow rate and microbial recovery efficiencies. A suite of four distinctly different microbes (MS2 bacteriophage, Enterococcus faecalis, Clostridium perfringens spores, and Cryptosporidium parvum oocysts) was studied to determine the performance of the DEUF method for simultaneous recovery of diverse microbes.  相似文献   

5.
Hollow-fiber ultrafiltration (UF) is a technique that has been reported to be effective for recovering a diverse array of microbes from water, and may also be potentially useful for microbial monitoring of effluent from water reclamation facilities. However, few data are available to indicate the potential limitations and efficacy of the UF technique for treated wastewater. In this study, recovery efficiencies were determined for various options available for performing the tangential-flow UF technique, including hollow-fiber ultrafilter (i.e., dialyzer) type, ultrafilter pre-treatment (i.e., blocking), and elution. MS2 and ΦX174 bacteriophages, Clostridium perfringens spores, Escherichia coli, and Cryptosporidium parvum oocysts were seeded into 10-L reclaimed water samples to evaluate UF options. Then a single UF protocol was established and studied using seeded and non-seeded 100-L samples from two water reclamation facilities in Georgia, USA. Baxter Exeltra Plus 210 and Fresenius F200NR dialyzers were found to provide significantly higher microbial recovery than Minntech HPH 1400 hemoconcentrators. The selected final UF method incorporated use of a non-blocked ultrafilter for UF followed by elution using a surfactant-based solution. For 10-L samples, this method achieved recovery efficiencies of greater than 50% recovery of seeded viruses, bacteria, and parasites. There was no significant difference in overall microbial recovery efficiency when the method was applied to 10- and 100-L samples. In addition, detection levels for pathogens in seeded 100-L reclaimed water samples were 1000 PFU HAV, 10,000 GI norovirus particles, < 500 Salmonella and < 200 Cryptosporidium oocysts. These data demonstrate that UF can be an effective technique for recovering diverse microbes in reclaimed water to monitor and improve effluent water quality in wastewater treatment plants.  相似文献   

6.
Methods for the simultaneous detection of Cryptosporidium parvum oocysts and Giardia cysts from water are described and their relative recovery efficiencies are assessed for seeded samples of both tap and river water. Cartridge filtration, membrane filtration, and calcium carbonate flocculation were evaluated, and steps to optimize the concentration procedures were undertaken. Increasing centrifugation to 5,000 x g, coupled with staining in suspension, was found to increase the overall efficiency of recovery of both cysts and oocysts. Cartridge filtration for both cysts and oocysts was examined by use of 100-liter volumes of both tap and river water. Improvements in recovery were observed for Cryptosporidium oocysts after extra washes of the filters. Calcium carbonate flocculation gave the maximum recovery for both Cryptosporidium oocysts and Giardia cysts and for both water types. A variety of 142-mm membranes was examined by use of 10-liter seeded samples of tap and river water. Cellulose acetate with a 1.2-micron pore size provided the best results for Cryptosporidium oocysts, and cellulose nitrate with a 3.0-micron pore size did so for Giardia cysts.  相似文献   

7.
The 1MDS electropositive microfilter was designed specifically for virus capture and recovery from water, but its electrostatic properties raise the possibility that 1MDS filters can also effectively capture bacteria and parasites present in water samples. This filter is recommended by United States Environmental Protection Agency (USEPA) for recovering human enteric viruses from water matrices through the Virus Adsorption-Elution (VIRADEL) technique. If bacteria and parasites can also be concentrated and recovered using 1MDS filters, this sampling technique would have greater utility and cost-effectiveness for microbial water quality testing. In this study, both 142-mm flat and 25.4-cm cartridge 1MDS filters (Cuno) were tested to determine their effectiveness for recovery of MS2 and phi X174 bacteriophage, Salmonella enterica (serovar Typhimurium), Bacillus globigii endospores, and Cryptosporidium parvum oocysts from a tap water matrix. By amending the USEPA standard beef extract/glycine eluent with a surfactant (Tween 80) and dispersant (sodium polyphosphate) and varying the pH and temperature, multiple eluent conditions were compared in order to identify an optimum eluent for all organisms. While viruses, bacteria, and parasites are effectively retained by the 1MDS filter, elution efficiencies and associated recovery efficiencies varied for each organism.  相似文献   

8.
The efficiency of virus recovery from water was investigated by using a method which enabled the concentration of a mixture of four enteroviruses with determination of their individual recovery efficiencies. The four viruses used (poliovirus 1, coxsackievirus A9, coxsackievirus B1, and echovirus 7) represented each of the four major subgroups of enteroviruses. This method, which was based on selective antibody neutralization, was used to investigate the effects of input water quality on enterovirus concentration by Balston filters (grade C; Balston, Inc., Lexington, Mass.) and organic flocculation. With tap water, the average recovery efficiency of the four viruses was 97%. Concentration from natural waters, including samples from two lakes (Lake Kinneret and the Hula Nature Reserve) and the Mediterranean Sea, resulted in similarly high average recovery efficiencies. Echovirus 7 was recovered with a slightly lower average efficiency from these types of water than were the other viruses. In comparison with other types of water, virus concentration from Jerusalem wastewater generally had a slightly lower efficiency of recovery, ranging from 63 to 75% for each of the viruses, with an overall average of 68%. The ability of each concentration step, membrane filtration or organic flocculation, to recover the viruses from water was assayed. For the filtration step, although there were not large differences in virus recoveries from tap water, echovirus 7 was recovered with the lowest efficiency (72%), and poliovirus 1 was recovered with the highest (87%) efficiency. Overall virus recovery by the filtration step was least efficient for wastewater (73%) and most efficient for seawater (107%).(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

9.
The efficiency of virus recovery from water was investigated by using a method which enabled the concentration of a mixture of four enteroviruses with determination of their individual recovery efficiencies. The four viruses used (poliovirus 1, coxsackievirus A9, coxsackievirus B1, and echovirus 7) represented each of the four major subgroups of enteroviruses. This method, which was based on selective antibody neutralization, was used to investigate the effects of input water quality on enterovirus concentration by Balston filters (grade C; Balston, Inc., Lexington, Mass.) and organic flocculation. With tap water, the average recovery efficiency of the four viruses was 97%. Concentration from natural waters, including samples from two lakes (Lake Kinneret and the Hula Nature Reserve) and the Mediterranean Sea, resulted in similarly high average recovery efficiencies. Echovirus 7 was recovered with a slightly lower average efficiency from these types of water than were the other viruses. In comparison with other types of water, virus concentration from Jerusalem wastewater generally had a slightly lower efficiency of recovery, ranging from 63 to 75% for each of the viruses, with an overall average of 68%. The ability of each concentration step, membrane filtration or organic flocculation, to recover the viruses from water was assayed. For the filtration step, although there were not large differences in virus recoveries from tap water, echovirus 7 was recovered with the lowest efficiency (72%), and poliovirus 1 was recovered with the highest (87%) efficiency. Overall virus recovery by the filtration step was least efficient for wastewater (73%) and most efficient for seawater (107%).(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

10.
The objective of this study was to adapt and evaluate two in vitro botulinum neurotoxin (BoNT) detection methods, including the Botulinum Toxin ELISA and the Endopep MS (a mass spectrometric-based endopeptidase method), for use with drinking water samples. The method detection limits (MDL) of the ELISA and Endopep MS were 260 pg/mL and 21 pg/mL of BoNT/A complex toxin, respectively. Since toxin could be present in water samples at highly dilute concentrations, large volume (100-L) samples of municipal tap water from five US municipalities having distinct water compositions were dechlorinated, spiked with 5 μg BoNT/A, and subjected to tangential-flow ultrafiltration (UF) using hollow fiber dialyzers. The recovery efficiency of BoNT/A using UF and quantified by ELISA ranged from 11% to 36% while efficiencies quantified by MS ranged from 26% to 55%. BoNT/A was shown to be stable in dechlorinated municipal tap water stored at 4°C for up to four weeks. In addition, toxin present in UF-concentrated water samples was also shown to be stable at 4°C for up to four weeks, allowing holding of samples prior to analysis. Finally, UF was used to concentrate a level of toxin (7 pg/mL) which is below the MDL for direct analysis by both ELISA and Endopep MS. Following UF, toxin was detectable in these samples using both in vitro analysis methods. These data demonstrate that UF-concentration of toxin from large volume water samples followed by use of existing analytical methods for detection of BoNT/A can be used in support of a monitoring program for contaminants in drinking water.  相似文献   

11.
The U.S. Environmental Protection Agency has developed method 1623 for simultaneous detection of Cryptosporidium oocysts and Giardia cysts in water. Method 1623 includes four major steps: filtration, immunomagnetic separation (IMS), fluorescent antibody (FA) staining and microscopic examination. It was noted that the recovery levels following IMS-FA and FA staining were high, averaging more than 92.0% and 89.0% for C. parvum oocysts and G. lamblia cysts, respectively. In contrast, when the filtration step was incorporated, the recovery level of C. parvum oocysts declined significantly to 18.1% in seeded tap water, while a relatively high recovery level of 77.2% for G. lamblia cysts could still be achieved. Further study indicated that the recovery level of C. parvum oocysts could be enhanced significantly when an appropriate amount of silica particles was added to a water sample. The recovery level of C. parvum oocysts was affected by particle size and concentration. The optimal silica particle size was determined to be within the range of 5-40 microm, and the corresponding optimal silica concentration was 1.42 g for 10-l tap water. When both G. lamblia cysts and C. parvum oocysts were spiked into the tap water sample containing the optimum amount of silica particles, the average recovery levels of oocysts and cysts were 82.7% and 75.4%, respectively. The results obtained clearly suggested that addition of an appropriate amount of silica particles could improve the recovery level of C. parvum oocysts significantly and yet there was no noticeable deleterious effect on the recovery level of G. lamblia cysts. Further study indicated that the rotation time in the IMS procedure using the Dynal GC-Combo IMS kit (which was recommended in method 1623) was important for G. lamblia cyst detection. In contrast, the recovery level of C. parvum oocysts was not affected by the rotation time. Furthermore, it was found that the recovery levels of C. parvum oocysts using methods 1622 and 1623 were quite close although different IMS kits were used in the two methods.  相似文献   

12.
AIMS: Evaluation of three flocculation methods for the purification of Cryptosporidium parvum oocysts from tap water. METHODS AND RESULTS: Ferric sulphate, aluminium sulphate and calcium carbonate were compared for their recovery efficiency of C. parvum oocysts from tap water. Lower mean recovery was achieved by calcium carbonate (38.8%) compared with ferric sulphate (61.5%) and aluminium sulphate (58.1%) for the recovery of 2.5 x 10(5) oocysts l(-1); 2.5 oocysts l(-1) and 1 oocyst l(-1) were adequately purified using ferric sulphate flocculation. In vitro excystation experiments showed that ferric sulphate flocculation does not markedly reduce the viability of oocysts. CONCLUSIONS: Ferric sulphate flocculation is a simple and effective tool for the purification of C. parvum oocysts from tap water. SIGNIFICANCE AND IMPACT OF THE STUDY: The high recovery rates and low impact on oocyst viability provided by ferric sulphate flocculation might be useful for the detection of Cryptosporidium oocysts in environmental water samples.  相似文献   

13.
The prevalence of pathogenic microorganisms in seawater can result in waterborne and food borne outbreaks. This study was performed to determine the effect of sunlight and salinity on the die-off of Cryptosporidium parvum. Cryptosporidium parvum oocysts, Escherichia coli, and MS2 coliphage were seeded into tap water and seawater samples and then exposed to sunlight. The die-off of C. parvum in seawater, as measured by infectivity, was greater under sunlight (-3.08 log10) than under dark conditions (-1.31 log10). While, no significant difference was recorded in the die-off of C. parvum, under dark conditions, in tap water as compared to seawater (P < 0.05), indicating that the synergistic effect of salinity and sunlight was responsible for the enhanced die-off in seawater. The die-off of MS2 coliphage and E. coli was greater than that observed for C. parvum under all tested conditions. This indicates that these microorganisms cannot serve as indicators for the presence of C. parvum oocysts in seawaters. The results of the study suggest that C. parvum can persist as infectious oocysts for a long time in seawater and can thus pose a serious hazard by direct and indirect contact with humans.  相似文献   

14.
Cryptosporidium parvum can be found in both source and drinking water and has been reported to cause serious waterborne outbreaks which threaten public health safety. The U.S. Environmental Protection Agency has developed method 1622 for detection of Cryptosporidium oocysts present in water. Method 1622 involves four key processing steps: filtration, immunomagnetic separation (IMS), fluorescent-antibody (FA) staining, and microscopic evaluation. The individual performance of each of these four steps was evaluated in this study. We found that the levels of recovery of C. parvum oocysts at the IMS-FA and FA staining stages were high, averaging more than 95%. In contrast, the level of recovery declined significantly, to 14.4%, when the filtration step was incorporated with tap water as a spiking medium. This observation suggested that a significant fraction of C. parvum oocysts was lost during the filtration step. When C. parvum oocysts were spiked into reclaimed water, tap water, microfiltration filtrate, and reservoir water, the highest mean level of recovery of (85.0% +/- 5.2% [mean +/- standard deviation]) was obtained for the relatively turbid reservoir water. Further studies indicated that it was the suspended particles present in the reservoir water that contributed to the enhanced C. parvum oocyst recovery. The levels of C. parvum oocyst recovery from spiked reservoir water with different turbidities indicated that particle size and concentration could affect oocyst recovery. Similar observations were also made when silica particles of different sizes and masses were added to seeded tap water. The optimal particle size was determined to be in the range from 5 to 40 micro m, and the corresponding optimal concentration of suspended particles was 1.42 g for 10 liters of tap water.  相似文献   

15.
噬藻体(Cyanophage)是一类感染蓝藻的病毒,形态上同于噬菌体,近期的研究表明,噬藻体作为水体环境中活跃的动态因子,在控制水体初级生产力和有害藻类水华(Harmful Algal Bloom,HAB)方面可能发挥着重要的作用,甚至影响水体生态系统中食物链的结构,因此研究水体中噬藻体的生理生态学特性对于了解其生态功能是非常重要的,但是由于自然水体中的噬藻体浓度往往较低,难以直接对其进行定性或定量研究,所以对天  相似文献   

16.
A new strategy for the detection of infectious Cryptosporidium parvum oocysts in water samples, which combines immunomagnetic separation (IMS) for recovery of oocysts with in vitro cell culturing and PCR (CC-PCR), was field tested with a total of 122 raw source water samples and 121 filter backwash water grab samples obtained from 25 sites in the United States. In addition, samples were processed by Percoll-sucrose flotation and oocysts were detected by an immunofluorescence assay (IFA) as a baseline method. Samples of different water quality were seeded with viable C. parvum to evaluate oocyst recovery efficiencies and the performance of the CC-PCR protocol. Mean method oocyst recoveries, including concentration of seeded 10-liter samples, from raw water were 26.1% for IMS and 16.6% for flotation, while recoveries from seeded filter backwash water were 9.1 and 5.8%, respectively. There was full agreement between IFA oocyst counts of IMS-purified seeded samples and CC-PCR results. In natural samples, CC-PCR detected infectious C. parvum in 4.9% (6) of the raw water samples and 7.4% (9) of the filter backwash water samples, while IFA detected oocysts in 13.1% (16) of the raw water samples and 5.8% (7) of the filter backwash water samples. All CC-PCR products were confirmed by cloning and DNA sequence analysis and were greater than 98% homologous to the C. parvum KSU-1 hsp70 gene product. DNA sequence analysis also revealed reproducible nucleotide substitutions among the hsp70 fragments, suggesting that several different strains of infectious C. parvum were detected.  相似文献   

17.
Solar disinfection (SODIS) of drinking water in polyethylene terephthalate (PET) bottles is a simple, efficient point-of-use technique for the inactivation of many bacterial pathogens. In contrast, the efficiency of SODIS against viruses is not well known. In this work, we studied the inactivation of bacteriophages (MS2 and ϕX174) and human viruses (echovirus 11 and adenovirus type 2) by SODIS. We conducted experiments in PET bottles exposed to (simulated) sunlight at different temperatures (15, 22, 26, and 40°C) and in water sources of diverse compositions and origins (India and Switzerland). Good inactivation of MS2 (>6-log inactivation after exposure to a total fluence of 1.34 kJ/cm2) was achieved in Swiss tap water at 22°C, while less-efficient inactivation was observed in Indian waters and for echovirus (1.5-log inactivation at the same fluence). The DNA viruses studied, ϕX174 and adenovirus, were resistant to SODIS, and the inactivation observed was equivalent to that occurring in the dark. High temperatures enhanced MS2 inactivation substantially; at 40°C, 3-log inactivation was achieved in Swiss tap water after exposure to a fluence of only 0.18 kJ/cm2. Overall, our findings demonstrate that SODIS may reduce the load of single-stranded RNA (ssRNA) viruses, such as echoviruses, particularly at high temperatures and in photoreactive matrices. In contrast, complementary measures may be needed to ensure efficient inactivation during SODIS of DNA viruses resistant to oxidation.  相似文献   

18.
Untreated cellulose filters adsorbed only small amounts of poliovirus 1, echovirus 5, coxsackievirus B5, or bacteriophage MS2 that were added to tap water or to solutions of imidazole-glycine buffer at pH 5 to 7. Modification of filters by in situ flocculation of ferric and aluminum hydroxides greatly increased the ability of the filters to adsorb viruses. Viruses adsorbed to the modified filters could be recovered by treating the filters with 3% beef extract (pH 9.5). Greater than 60% of the enteroviruses and greater than 55% of the MS2 added to tap water or buffer could be recovered in the beef extract eluate.  相似文献   

19.
Untreated cellulose filters adsorbed only small amounts of poliovirus 1, echovirus 5, coxsackievirus B5, or bacteriophage MS2 that were added to tap water or to solutions of imidazole-glycine buffer at pH 5 to 7. Modification of filters by in situ flocculation of ferric and aluminum hydroxides greatly increased the ability of the filters to adsorb viruses. Viruses adsorbed to the modified filters could be recovered by treating the filters with 3% beef extract (pH 9.5). Greater than 60% of the enteroviruses and greater than 55% of the MS2 added to tap water or buffer could be recovered in the beef extract eluate.  相似文献   

20.
The detection and identification of pathogens from water samples remain challenging due to variations in recovery rates and the cost of procedures. Ultrafiltration offers the possibility to concentrate viral, bacterial, and protozoan organisms in a single process by using size-exclusion-based filtration. In this study, two hollow-fiber ultrafilters with 50,000-molecular-weight cutoffs were evaluated to concentrate microorganisms from 2- and 10-liter water samples. When known quantities (10(5) to 10(6) CFU/liter) of two species of enteric bacteria were introduced and concentrated from 2 liters of sterile water, the addition of 0.1% Tween 80 increased Escherichia coli strain K-12 recoveries from 70 to 84% and Salmonella enterica serovar Enteritidis recoveries from 36 to 72%. An E. coli antibiotic-resistant strain, XL1-Blue, was recovered at a level (87%) similar to that for strain K-12 (96%) from 10 liters of sterile water. When E. coli XL1-Blue was introduced into 10 liters of nonsterile Rio Grande water with higher turbidity levels (23 to 29 nephelometric turbidity units) at two inoculum levels (9 x 10(5) and 2.4 x 10(3) per liter), the recovery efficiencies were 89 and 92%, respectively. The simultaneous addition of E. coli XL1-Blue (9 x 10(5) CFU/liter), Cryptosporidium parvum oocysts (10 oocysts/liter), phage T1 (10(5) PFU/liter), and phage PP7 (10(5) PFU/liter) to 10 liters of Rio Grande surface water resulted in mean recoveries of 96, 54, 59, and 46%, respectively. Using a variety of surface waters from around the United States, we obtained recovery efficiencies for bacteria and viruses that were similar to those observed with the Rio Grande samples, but recovery of Cryptosporidium oocysts was decreased, averaging 32% (the site of collection of these samples had previously been identified as problematic for oocyst recovery). Results indicate that the use of ultrafiltration for simultaneous recovery of bacterial, viral, and protozoan pathogens from variable surface waters is ready for field deployment.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号