首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A quantitative analytical method using automated on-line solid phase extraction (SPE) and liquid chromatography-electrospray tandem mass spectrometry (LC-ESI-MS/MS) for the determination of 8-OHdG (8-hydroxy-2'-deoxyguanosine) in human plasma was developed and validated. A one-step membrane extraction method for the plasma sample preparation and a C18 SPE column with simple extraction and purification were used for the on-line extraction. A C18 column was employed for LC separation and ESI-MS/MS was utilized for detection. (15)N(5)-8-OHdG ((15)N(5)-8-hydroxy-2'-deoxyguanosine) was used as an internal standard for quantitative determination. The extraction, clean-up and analysis procedures were controlled by a fully automated six-port switch valve as one strategy to reduce the matrix effect and simultaneously improve detection sensitivity. Identification and quantification were based on the following transitions: m/z 284→168 for 8-OHdG and m/z 289→173 for (15)N(5)-8-OHdG. Satisfactory recovery was obtained, and the recovery ranged from 95.1 to 106.1% at trace levels in human plasma and urine, with a CV lower than 5.4%. Values for intraday and interday precision were between 2.3 and 6.8% for plasma and between 2.7 and 4.5% for urine, respectively. Values for the method accuracy of intraday and interday assays ranged from 93.0 and 100.5% for plasma and 110.2 and 119.4% for urine, respectively. The limits of detection (LOD) and LOQ were 0.008 ng/mL and 0.02 ng/mL, respectively.The applicability of this newly developed method was demonstrated by analysis of human plasma samples for an evaluation of the future risk of oxidative stress status in human exposure to nanoparticles and other diseases.  相似文献   

2.
A specific LC-MS/MS assay was developed for the automated determination of talinolol in human plasma, using on-line solid phase extraction system (prospekt 2) combined with atmospheric pressure chemical ionization (APCI) tandem mass spectrometry. The method involved simple precipitation of plasma proteins with perchloric acid (contained propranolol) as the internal standard (IS) and injection of the supernatant onto a C8 End Capped (10 mmx2 mm) cartridge without any evaporation step. Using the back-flush mode, the analytes were transferred onto an analytical column (XTerra C18, 50 mmx4.6 mm) for chromatographic separation and mass spectrometry detection. One of the particularities of the assay is that the SPE cartridge is used as a column switching device and not as an SPE cartridge. Therefore, the same SPE cartridge could be used more than 28 times, significantly reducing the analysis cost. APCI ionization was selected to overcome any potential matrix suppression effects because the analyte and IS co-eluted. The mean precision and accuracy in the concentration range 2.5-200 ng/mL was found to be 103% and 7.4%, respectively. The data was assessed from QC samples during the validation phase of the assay. The lower limit of quantification was 2.5 ng/mL, using a 250 microL plasma aliquot. The LC-MS/MS method provided the requisite selectivity, sensitivity, robustness accuracy and precision to assess pharmacokinetics of the compound in several hundred human plasma samples.  相似文献   

3.
Turbulent flow chromatograph (TFC) is a technique for the direct and efficient analysis of drugs and metabolites in biological matrices. We report here TFC on-line with an HPLC-MS/MS assay for the determination of 5-[2,4-dioxothiazolidin-5-yl)methyl]-2-methoxy-N-[[(4-trifluoromethyl)phenyl]methyl]benzamide (I, MK-0767, KRP297, Fig. 1) in plasma. Samples were transferred using an automated system followed by the addition of internal standard (II), prepared in 0.1 M ammonium acetate (pH 4.0). The plasma samples were directly injected onto a C18 turbulent flow column on-line with an HPLC-MS/MS system, and the analytical column used was a ThermoHypersil Keystone C18. Detection was achieved by MS/MS, using positive ionization on a TurboIonSpray probe, operated in multiple reaction monitoring (MRM) mode. The linear range was 4-2000 ng/mL for I when using 50 microL of plasma. The method exhibited good linearity and reproducibility. The method also showed good selectivity and ruggedness when applied to clinical samples, and was successfully cross-validated with a conventional off-line SPE, LC-MS/MS method.  相似文献   

4.
We present a method for determining two cephalosporins (cefoperazone and ceftiofur) in plasma by on-line solid-phase extraction (SPE)-capillary zone electrophoresis (CZE) with a T-split interface. Using this interface, a part of the SPE elution plug containing the cephalosporins is injected while the rest of the sample is flushed to waste. SPE was carried out using a C(18) micro-precolumn and the cephalosporins presented good retention properties with breakthrough volumes above 1 ml. Using a desorption volume of 426 nl of acetonitrile, recoveries were 75 and 90%, for cefoperazone and ceftiofur, respectively. The resulting elution volume was about 1.8 microl. A deproteinization step was included prior to SPE for the analysis of plasma samples with recoveries of 90 and 57% for cefoperazone and ceftiofur, respectively. With UV detection at 254 nm, linear relationships between the injected concentration and peak area was measured between 10 and 500 ng ml(-1) for standards, and 200 and 1500 ng ml(-1) for plasma samples. Intra-day (n=5) and inter-day (n=5) peak area repeatability were lower than 12% RSD. The detection limits obtained for spiked plasma (100 ng ml(-1) cefoperazone and ceftiofur) are sufficient for applying the method to pharmacokinetic studies.  相似文献   

5.
Duloxetine is the most recent serotonin and norepinephrine reuptake inhibitor (SNRI) drug introduced for the therapy of depression. Thus, it is evident that there is a need for having on hand new reliable analytical methods for the determination of duloxetine plasma levels in depressed patients. The present paper deals with the development of a rapid and sensitive high-performance liquid chromatographic method for duloxetine analysis in human plasma. The assays were carried out using a C8 reversed-phase column and a mobile phase composed of 60% aqueous phosphate buffer containing triethylamine at pH 3.0 and 40% acetonitrile. The UV detector was set at 230 nm and loxapine was used as the internal standard. An original pre-treatment of plasma samples was developed, based on solid-phase extraction (SPE) with mixed-mode reversed phase-strong cation exchange cartridges (30 mg, 1 mL). The extraction yields values were higher than 90%. Linearity was found in the 2-200 ng mL(-1) duloxetine concentration range; the limit of quantitation was 2.0 ng mL(-1) and the limit of detection was 0.7 ng mL(-1). The method was applied to plasma samples from depressed patients undergoing therapy with duloxetine. Precision data and accuracy results were satisfactory and no interference from other drugs was found. Thus, the method seems to be suitable for the therapeutic drug monitoring of duloxetine in depressed patients' plasma.  相似文献   

6.
A rapid, robust and selective on-line solid-phase extraction-liquid chromatographic method with ultra-violet detection (on-line SPE-LC-UV) for microsomal prostaglandin E(2) synthase-1 (mPGES-1) inhibitor screening was developed and validated. Disrupted A549 cells were used as mPGES-1 source and the formation of prostaglandin E(2) (PGE(2)) out of the substrate prostaglandin H(2) (PGH(2)) was determined at 195 nm. Direct on-line sample clean up was achieved by automated column switch (C18 trap column) prior isocratic separation using a C18 analytical column. The on-line SPE-LC-UV method was accurate, precise and reproducible in the range of 71-1763 ng/ml for PGE(2) and met the generally accepted criteria for bioanalytical methods. The method was successfully applied to determine the IC(50) value of the known mPGES-1 inhibitor NS-398.  相似文献   

7.
A simple, sensitive and selective high performance liquid chromatography (HPLC) method with ultraviolet detection (272 nm) was developed and validated for the simultaneous quantification of theophylline and etofylline in human plasma. Following rapid sample preparation, the analytes and internal standard (hydrochlorothiazide) were separated using an isocratic mobile phase on a reverse phase C18 column. The lower limit of quantification was 100 ng/mL for both theophylline and etofylline with a relative standard deviation of less than 6%. A linear dynamic range of 100-10,000 ng/mL for both theophylline and etofylline was established. This HPLC method was validated with between-batch precision of 2.2-6.0 and 1.4-3.7% for theophylline and etofylline, respectively. The between-batch accuracy was 94.3-98.0 and 95.4-98.2%, respectively. Stability of theophylline and etofylline in plasma was excellent, with no evidence of degradation during sample processing (autosampler) and 30 days storage in a freezer. This validated method is simple and rugged enough to be used in pharmacokinetic studies.  相似文献   

8.
We have developed and validated a method for the quantification of fentanyl, a synthetic opioid, in dog plasma by on-line SPE with a hydrophilic column coupled to tandem mass spectrometry in positive electrospray mode. A column-switching instrument with 10-port valve and two HPLC pumping systems were employed. Deuterated fentanyl served as the internal standard. A Waters Oasis HLB extraction column and a Waters Atlantis HILIC Silica analytical column in a column-switching set-up with gradient elution were utilized. Both fentanyl (analyte) and the internal standard (fentanyl-d5) were determined via multiple reaction monitoring (MRM) and the MS/MS ion transitions monitored were m/z 337.0/188.0 and 342.0/188.0, respectively. Each plasma sample was chromatographed within 5 min. The calibration curves were linear over a widely range of 0.01-50 ng/mL using weighted linear regression analysis (1/x). The low limit of quantitation was 0.01 ng/mL. The intra- and inter-day accuracy ranged from 102 to 112% and the overall precision was less than 3%. The recoveries ranged from 90 to 105% in plasma at the concentrations of 0.04, 0.4, 4 and 40 ng/mL. No influence of freeze/thaw and long-term stability were observed. This validated method has been successfully applied to analyze the dog plasma samples of a pharmacokinetics study.  相似文献   

9.
A new, selective and sensitive high-performance liquid chromatography (HPLC) method with fluorimetric detection was developed for the determination of tianeptine (TIA) in human plasma using solid phase extraction (SPE) procedures. The method is based on the derivatization of TIA with 4-chloro-7-nitrobenzofurazan (NBD-Cl) in borate buffer of pH 8.5 to yield a yellow, fluorescent product. The HPLC separation was achieved on a Phenomenex C(18) column (250 mm x 4.6 mm) using a mobile phase of acetonitrile-10mM orthophosphoric acid (pH 2.5) (77:23, v/v) solvent system at 1 mL/min flow rate. Gabapentin (GA) was used as the internal standard. The fluorometric detector was operated at 458 nm (excitation) and 520 nm (emission). The assay was linear over the concentration range of 5-300 ng/mL. The detection limit (LOD) was found to be 2 ng/mL. The mean recovery was determined to be 88.6%. The proposed method was applied for pharmacokinetic study of 12.5mg TIA in a healthy volunteer.  相似文献   

10.
A rapid and sensitive reversed-phase liquid chromatographic method (RP-LC) with UV detection has been developed for the determination of free cortisol, cortisone and corticosterone in human urine. The assay was performed after a solid-phase extraction procedure (SPE) with dexamethasone as the internal standard. Chromatographic separation was carried out on a Nucleosil 100 C(18) analytical column using a mixture of acetonitrile and water (30 : 70, v/v) as a mobile phase at a flow-rate of 1 mL min(-1). Spectrophotometric detection was performed at 240 nm. The method has been validated for accuracy, precision, selectivity, linearity, recovery and stability. The absolute recoveries of glucocorticoids were above 94.6%. The limits of detection (LOD) and quantification (LOQ) were 0.5 and 2 ng mL(-1), respectively, for all analytes. Linearity was confirmed in the range of 2-300 ng mL(-1) with a correlation coefficient greater than 0.9997 for all steroid hormones. The proposed method was sensitive, robust and specific allowing reliable quantification of steroid hormones. This method was successfully applied for determination of three endogenous glucocorticoid levels in human urine. The studies were performed on 20 sedentary healthy volunteers in comparison to two socially diversified groups, namely 10 parachutists before and after jump and 10 patients with depression. Pharmacokinetic studies performed on these groups indicated that urinary free cortisol and cortisol-to-cortisone ratios can be treated as biomarkers of stress and depressive disorders.  相似文献   

11.
A rapid and sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS) method was developed and validated for simultaneous quantification of valsartan and hydrochlorothiazide in human plasma. After a simple protein precipitation using acetonitrile, the analytes were separated on a Zorbax SB-Aq C18 column using acetonitrile-10mM ammonium acetate (60:40, v/v, pH 4.5) as mobile phase at a flow rate of 1.2 mL/min. Valsartan and hydrochlorothiazide were eluted at 2.08 min and 1.50 min, respectively, ionized using ESI source, and then detected by multiple reaction monitoring (MRM) mode. The precursor to product ion transitions of m/z 434.2-350.2 and m/z 295.9-268.9 were used to quantify valsartan and hydrochlorothiazide, respectively. The method was linear in the concentration range of 4-3600 ng/mL for valsartan and 1-900 ng/mL for hydrochlorothiazide. The method was successfully employed in a pharmacokinetic study after an oral administration of a dispersible tablet containing 80 mg valsartan and 12.5 mg hydrochlorothiazide to each of the 20 healthy volunteers.  相似文献   

12.
An improved liquid chromatographic method with on-line solid phase extraction (SPE) and tandem mass spectrometric detection was optimised for quantification of the anti-HIV peptide Sifuvirtide in human plasma. The SPE sorbents, loading buffer composition and other aspects of the on-line SPE column were investigated in detail for efficiently extracting the interesting peptides and simultaneously discarding the large amount of proteins. The gradient elution program was optimised on the analysis column to decrease the matrix effect and obtain excellent selectivity. The multiple charge ion at m/z 946.4 of Sifuvirtide was quantified by a linear ion trap mass spectrometer, operating in the positive mode, and selective reaction monitoring (SRM) acquisition. Method validation results demonstrated that the linear calibration curve covered a range of 6.1–6250 ng/mL, and the correlation coefficients (r2) were above 0.992. The lower limit of detection (LLOD) with a signal-to-noise (S/N) ratio higher than 10 was 6.1 ng/mL. The accuracy ranged from −7.6 to 10.6%, and the intra- and inter-batch precisions were less than 8.7% and 5.5%, respectively. Finally, more than nine hundred of samples from a clinical trial was completely analyzed using this on-line SPE coupled HPLC–MS/MS system in one single week, due to the rapid run-time of individual sample (6.5 min).  相似文献   

13.
Glabridin is a major flavonoid included specifically in licorice (Glycyrrhiza glabra L.), and has various physiological activities including antioxidant and anti-inflammatory effects. We have developed and validated an analytical method for determination of glabridin in human plasma by solid-phase extraction (SPE) and LC-MS/MS. Glabridin was extracted from plasma by SPE using a C8 cartridge and analyzed by LC-MS/MS using mefenamic acid as an internal standard (IS). The analyte were separated by a C18 column on LC, and monitored with a fragment ion of m/z 201 formed from a molecular ion of m/z 323 for glabridin and that of m/z 196 from m/z 240 for IS during negative ion mode with tandem MS detection. The lower limit of quantitation (LLOQ) of glabridin was 0.1 ng/mL in plasma, corresponding to 1.25 pg injected on-column. The calibration curves exhibited excellent linearity (r>0.997) between 0.1 and 50 ng/mL. Precision and accuracy were <17 and <+/-7% at LLOQ, and <11 and <+/-5% at other concentrations. Glabridin was recovered >90%, and was stable when kept at 10 degrees C for 72 h, at -20 degrees C until 12 weeks, and after three freeze-thaw cycles. This is the first report on determination of glabridin in body fluids by the selective, sensitive, and reproducible method.  相似文献   

14.
A method for the quantification of salidroside, a major biologically active compound in Rhodiola, in rat plasma by on-line SPE LC/MS/MS in negative electrospray mode was developed and validated. A column-switching instrument and two HPLC pumping systems were employed, and salicin was used as the internal standard. A Waters Oasis HLB extraction column and an Agilent TC-C(18) analytical column in a column-switching set-up with gradient elution were utilized. The MS/MS ion transitions monitored were m/z 299.0/119.0 and 285.1/122.9 for salidroside and salicin, respectively. The standard curves were linear within a range of 50-5000 ng/mL using weighted linear regression analysis (1/x). The intra- and inter-day coefficients of variance ranged from 1% to 9%. The recovery was above 90%. The freeze/thaw and long-term stability were validated. This method was subsequently applied to a pharmacokinetic study of salidroside in rats.  相似文献   

15.
A rapid and sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method has been developed and validated for the simultaneous estimation of hydrochlorothiazide, quinapril and its metabolite quinaprilat in human plasma. After solid phase extraction (SPE), the analytes and IS were chromatographed on a hypurity C8 (100mmx2.1mm i.d., 5mum particle size) column using 2muL injection volume with a run time of 2.8min. An isocratic mobile phase consisting of 0.5% (v/v) formic acid:acetonitrile (25:75, v/v) was used to separate all these drugs. The precursor and product ions of these drugs were monitored on a triple quadrupole mass spectrometer, operating in the multiple reaction monitoring mode (MRM) without polarity switch. The proposed method was validated over the range of 5-500ng/mL for hydrochlorothiazide method and 5-1500ng/mL for quinapril and quinaprilat. Inter-batch and intra-batch precision (coefficient of variation - % CV) across five validation runs lower limit of quantitation (LLOQ), lower quality control (LQC), middle quality control (MQC), higher quality control (HQC) and upper limit of quantitation (ULOQ) was less than 15. The accuracy determined at these levels was within +/-13% in terms of relative percentage error.  相似文献   

16.
A high-performance liquid chromatographic method has been developed for the determination of the recent serotonin and norepinephrine reuptake inhibitor (SNRI) venlafaxine and its main active metabolite, O-desmethylvenlafaxine, in human plasma. Separation was obtained by using a reversed-phase column (C8, 150 x 4.6 mm I.D., 5 microm) and a mobile phase composed of 75% aqueous phosphate buffer containing triethylamine at pH 6.8 and 25% acetonitrile. Fluorescence detection was used, exciting at lambda=238 nm and monitoring the emission at lambda=300 nm. Citalopram was used as the internal standard. A careful pre-treatment of plasma samples was developed, using solid-phase extraction with C1 cartridges (100 mg, 1 mL). The limit of quantification (LOQ) was 1.0 ng mL(-1) and the limit of detection (LOD) was 0.3 ng mL(-1) for both analytes. The method was applied with success to plasma samples taken from patients undergoing treatment with venlafaxine. Precision data, as well as accuracy results, were satisfactory and no interference from other drugs was found. Hence, the method is suitable for therapeutic drug monitoring of venlafaxine and its main metabolite in depressed patients' plasma.  相似文献   

17.
Atractylenolide III is a major active component in Atractylodes macrocephala. This paper describes a simple, rapid, specific and sensitive method for the quantification of atractylenolide III in rat plasma using a liquid-liquid extraction procedure followed by liquid chromatography mass spectrometric (LC-MS) analysis. A Kromasil 3.5 microm C(18) column (150 mm x 2.00 mm) was used as the analytical column. Linear detection responses were obtained for atractylenolide III concentration ranging from 5 to 500 ng L(-1). The precision and accuracy data, based on intra-day and inter-day variations over 5 days were within 10.29%. The lower limit of quantitation for atractylenolide III was 5 ng mL(-1), using 0.1 mL plasma for extraction and its recoveries were greater than 85% at the low, medium and high concentrations. The method has been successfully applied to a pharmacokinetic study in rats after an oral administration of atractylenolide III with a dose of 20.0 mg kg(-1). With the lower limits of quantification at 5 ng mL(-1) for atractylenolide III, this method was proved to be sensitive enough for the pharmacokinetics study of atractylenolide III.  相似文献   

18.
The first HPLC-fluorescence method for the determination of atomoxetine in human plasma was developed and validated. Atomoxetine was derivatized with 4-(4,5-diphenyl-1H-imidazol-2-yl) benzoyl chloride (DIB-Cl) under mild conditions, and separated isocratically on a C18 column using a HPLC system with fluorescence detection (lambdaex: 318 nm, lambdaem: 448 nm). A linear calibration curve was obtained over the concentration range 1-1000 ng/mL (r=0.999). The limit of detection (S/N=3) was 0.3 ng/mL. The relative standard deviations of intra-day and inter-day variations were < or =8.30% and 7.47%, respectively. This method is rapid, sensitive, and suitable for both basic and clinical studies of atomoxetine.  相似文献   

19.
A number of analytical methods have been established to quantify methylphenidate (MPH). However, to date no HPLC methods are applicable to human pharmacokinetic studies without the use of mass spectrometry (MS) detection. We developed a sensitive and reliable HPLC-fluorescence method for the determination of MPH in human plasma using 4-(4,5-diphenyl-1H-imidazol-2-yl) benzoyl chloride (DIB-Cl) as the derivatizing agent. An established GC-MS method was adopted in this study as a comparator assay. MPH was derivatized using DIB-Cl, and separated isocratically on a C18 column using a HPLC system with fluorescence detection (lambda(ex)=330 nm, lambda(em)=460 nm). The lower limit of quantification was found to be 1 ng/mL. A linear calibration curve was obtained over the concentrations ranging from 1 ng/mL to 80 ng/mL (r=0.998). The relative standard deviations of intra-day and inter-day variations were 相似文献   

20.
Solid phase extraction (SPE) was coupled at line to capillary electrophoresis (CE) for the determination of three basic and neutral diabetic drugs (metformin, phenformin and glyburide) in human plasma. The SPE procedure employed a C(18) cartridge to remove most of the water and proteins from the plasma sample. Analyte detectability was increased due to trace enrichment during the SPE process. Elution of metformin, phenformin and glyburide was achieved with methanol+3% acetic acid. CE analysis was performed using a non-aqueous buffer, acetonitrile+5mM ammonium acetate+5% acetic acid, which afforded rapid separation of metformin from phenformin within 3 min. Glyburide, with a migration time longer than 6 min, did not cause any interference. The present SPE-CE method, with an electrokinetic injection time of 6s and UV detection at 240 nm, was useful for monitoring down to 1 microg/mL of metformin and phenformin in human plasma. When the electrokinetic injection time was increased to 36s, the detection limits were improved to 12 ng/mL for metformin and 6 ng/mL for phenformin.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号