首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A sensitive and accurate assay was developed and validated to determine BNP7787 (dimesna), a new protector against cisplatin-induced toxicities, and its metabolite mesna in plasma and urine of patients. Both analytes were measured as mesna in deproteinized plasma or in urine diluted with mobile phase using high-performance liquid chromatography with an electrochemical detector provided with a wall-jet gold electrode. The assays for BNP7787 and mesna in deproteinized plasma were linear over the range of 1.6–500 μM and 0.63–320 μM, respectively. In plasma, the mean recovery of BNP7787 over the whole concentration range was 100.6% and of mesna 94.6%. The lower limits of quantitation (LLQs) of BNP7787 and mesna in deproteinized plasma were 1.6 μM and 0.63 μM, respectively. For both compounds the within- and between-day accuracy and precision of the assay was better than 12%. The assays for BNP7787 and mesna in urine were linear over the range of 0.8–1200 μM and 0.63–250 μM, respectively. In urine, the mean recovery of BNP7787 over the whole concentration range was 94.1% and of mesna 93.1%. The LLQ of BNP7787 in urine was 0.8 μM and of mesna 1.6 μM. The within- and between-day accuracy and precision of the assay for BNP7787 and mesna was lower than 15%. The stability of mesna in urine increased with an increasing concentration of mesna, lower temperature and addition of EDTA (1 g/l) and hydrochloric acid (0.2 M). BNP7787 in urine was stable for at least 24 h at temperatures in the range of −20°C up to 37°C and independent of the concentration. The developed assays are currently applied for samples of patients with solid tumors participating in a phase I trial of BNP7787 in combination with cisplatin.  相似文献   

2.
A simple purge-and-trap gas chromatographic method with flame ionization detection was developed for the determination of styrene in urine and blood. Styrene present in a 5 ml sample at room temperature was swept by helium at 40 ml/min for 11 min, trapped on a Tenax trap, desorbed by heating, cryofocused, and injected by flash heating into a DB-5 capillary GC column. The oven temperature program was from 80°C, held for 8 min, to 120°C at 5°C/min, and then held for 2 min. The detector temperature was 250°C. The calibration curves were linear in the range of 2.5–15 ppb styrene in urine and 25–150 ppb in blood. The detection limits calculated were 0.4 μg/l in urine and 0.6 μg/l in blood. The coefficients of variations within the day and day-to-day were 3 and 3.1%, respectively, for 2.5 ppb of styrene in urine, and 1 and 1.6% for 25 ppb of styrene in blood. The results obtained from samples taken from workers exposed to styrene were reported.  相似文献   

3.
A sensitive and specific high-performance liquid chromatographic (HPLC) method with UV detection was developed for the determination of minocycline in human plasma and parotid saliva samples. Samples were extracted using an Oasis™ HLB cartridge and were injected into a C8 Nucleosil column. The HPLC eluent contained acetonitrile–methanol–distilled water–0.1% trifluoroacetic acid (25:2:72.9:0.1, v/v). Demeclocycline was used as internal standard. The assay showed linearity in the tested range of 0.1–25 μg/ml. The limit of quantitation was 100 ng/ml. Recovery from plasma or parotid saliva averaged 95%. Precision expressed as %CV was in the range 0.2–17% (limit of quantitation). Accuracy ranged from 93 to 111%. In the two matrices studied at 20 and 4°C, rapid degradation of the drug occurred. Frozen at −30°C, this drug was stable for at least 2 months, the percent recovery averaged 90%. The method’s ability to quantify minocycline with precision, accuracy and sensitivity makes it useful in pharmacokinetic studies.  相似文献   

4.
An analytical method for the assessment of the exposure of workers to the pesticide propoxur through biological monitoring has been developed. This study was part of a survey of occupational exposure to pesticides used in greenhouses for the growing of ornamental plants. In order to assess the actual absorbed amount of propoxur in the body, an analytical method for its metabolite 2-isopropoxyphenol in urine was required. This led to the development of a gas chromatographic—mass spectrometric assay involving hydrolysis and solvent extraction. A mass-selective detector, operated in single-ion mode, provides a selective and sensitive quantification of 2-isopropoxyphenol with a detection limit of 6 μg/l. The method has been validated with respect to the hydrolysis of urine samples, analytical recovery of 2-isopropoxyphenol, stability of its conjugates, limit of detection, background and precision. The analytical recovery from spiked urine was over 95%. 2-Isopropoxyphenol was excreted in urine as a conjugate and was stable for at least seven months when stored at − 20°C. It was not detected in urine from non-exposed persons. Between-day coefficients of variation were 20, 10, 7 and 4% for concentrations of 15, 29, 150 and 213 μg/l, respectively. Measured as 2-isopropoxyphenol, ca. 80% of an orally administered dose of propoxur was excreted in urine within 10 h.  相似文献   

5.
A reversed-phase (RP) high-performance liquid chromatographic (HPLC) method with fluorescence detection allowing the sensitive and specific quantification of BAY 12-8039, a new antimicrobially active 8-methoxyquinolone, in biological fluids is described. The method is compared to a microbiological assay (bioassay) based on B. subtilis test strain with a limit of quantification of approximately 60 μg/l. Following dilution and centrifugation, plasma, saliva or urine supernatant is directly injected onto the HPLC system. Concentrations down to a limit of quantification of 2.5 μg/l can be quantified in plasma, saliva and urine. Data on recovery, accuracy and precision of the method throughout the whole working range as well as results on stability of the analyte are presented. The concentration data are correlated with results from the bioassay. BAY 12-8039 is stable in plasma after repeated freeze-thaw cycles and following storage at −20°C for at least 12 months. The results of HPLC measurements excellently agree with bioassay data indicating the relevance of the method as a tool in clinical development to answer pharmacokinetic questions related to antimicrobial activity. The method was applied to human plasma, saliva and urine from subjects after a single oral dose of 400 mg of BAY 12-8039.  相似文献   

6.
We measured Na+/K+ ATPase activity in homogenates of gill tissue prepared from field caught, winter and summer acclimatized yellow perch, Perca flavescens. Water temperatures were 2–4°C in winter and 19–22°C in summer. Na+/K+ ATPase activity was measured at 8, 17, 25, and 37°C. Vmax values for winter fish increased from 0.48±0.07 μmol P mg−1 protein h−1 at 8°C to 7.21±0.79 μmol P mg−1 protein h−1 at 37°C. In summer fish it ranged from 0.46±0.08 (8°C) to 3.86±0.50 (37°C) μmol P mg−1 protein h−1. The Km for ATP and for Na+ at 8°C was ≈1.6 and 10 mM, respectively and did not vary significantly with assay temperature in homogenates from summer fish. The activation energy for Na+/K+ ATPase from summer fish was 10 309 (μmol P mg−1 h−1) K−1. In winter fish, the Km for ATP and Na+ increased from 0.59±0.08 mM and 9.56±1.18 mM at 8°C to 1.49±0.11 and 17.88±2.64 mM at 17°C. The Km values for ATP and Na did not vary from 17 to 37°C. A single activation energy could not be calculated for Na/K ATPase from winter fish. The observed differences in enzyme activities and affinities could be due to seasonal changes in membrane lipids, differences in the amount of enzyme, or changes in isozyme expression.  相似文献   

7.
A rapid and simple high-performance liquid chromatographic method with amperometric detection has been developed for the quantitation of cilazapril and its active metabolite and degradation product cilazaprilat in urine and tablets. The chromatographic system consisted of a μBondapak C18 column, using a mixture of methanol–5 mM phosphoric acid (50:50, v/v) as mobile phase, which was pumped at a flow-rate of 1.0 ml/min. The column was kept at a constant temperature of (40±0.2)°C. Detection was performed using a glassy carbon electrode at a potential of 1350 mV. Sample preparation for urine consisted of a solid-phase extraction using C8 cartridges. This procedure allowed recoveries greater than 85% for both compounds. The method proved to be accurate, precise and sensitive enough to be applied to pharmacokinetic studies and it has been applied to urine samples obtained from four hypertensive patients (detection limit of 50 ng/ml for cilazapril and 40 ng/ml for cilazaprilat in urine). Results were in good agreement with pharmacokinetic data.  相似文献   

8.
A hydrogen peroxide permselective membrane with asymmetric structure was prepared and -glucose oxidase (EC 1.1.3.4) was immobilized onto the porous layer. The activity of the immobilized -glucose oxidase membrane was 0.34 units cm−2 and the activity yield was 6.8% of that of the native enzyme. Optimum pH, optimum temperature, pH stability and temperature stability were found to be pH 5.0, 30–40°C, pH 4.0–7.0 and below 55°C, respectively. The apparent Michaelis constant of the immobilized -glucose oxidase membrane was 1.6 × 10−3 mol l−1 and that of free enzyme was 4.8 × 10−2 mol l−1. An enzyme electrode was constructed by combination of a hydrogen peroxide electrode with the immobilized -glucose oxidase membrane. The enzyme electrode responded linearly to -glucose over the concentration 0–1000 mg dl−1 within 10 s. When the enzyme electrode was applied to the determination of -glucose in human serum, within day precision (CV) was 1.29% for -glucose concentration with a mean value of 106.8 mg dl−1. The correlation coefficient between the enzyme electrode method and the conventional colorimetric method using a free enzyme was 0.984. The immobilized -glucose oxidase membrane was sufficiently stable to perform 1000 assays (2 to 4 weeks operation) for the determination of -glucose in human whole blood. The dried membrane retained 77% of its initial activity after storage at 4°C for 16 months.  相似文献   

9.
Solid-phase microextraction (SPME) is a unique extraction and sampling technique, and it has been used for separation of volatile organics from water or other simple matrices. In this study, we have used SPME to separate dinitroaniline herbicides from complicated matrices of human urine and blood in order to broaden its application to biomedical analysis. The SPME conditions were optimized for water, urine and blood samples, in terms of pH, salt additives, extraction temperature, and fiber exposure time. Urine or water (1.0 ml) spiked with herbicides and 0.28 g of anhydrous sodium sulfate was preheated at 70°C for 10 min, and a polydimethylsiloxane-coated fiber for SPME was exposed to the headspace at 70°C for another 30 min; while spiked blood (0.5 ml) diluted with water (0.5 ml) was treated at 90°C in the same way. The herbicides were extractable under these conditions, and could be determined by gas chromatography–electron capture detector (GC–ECD). The recoveries of the herbicides, measured at the concentrations of 0.50 and 1.0 ng/ml urine or water, or 6.0 and 20 ng/0.5 ml blood, ranged from 35 to 64% for different herbicides from water or urine, and from 3.2 to 7.2% from blood. The headspace SPME yielded clean extracts of dinitroaniline herbicides from urine, blood or water, which could be directly analyzed by GC–ECD without further purification. The peak areas of the extracted herbicides were proportional to their concentrations in the range 0.1–10 ng/ml in water or urine, or 1–60 ng/0.5 ml in blood. The lowest detectable concentration of the herbicides lay in 0.1 ng/ml water or urine, or in 0.5 ng/0.5 ml blood. The intra- and inter-day coefficients of variation were within 14% for most of the analytes. Although the recoveries of the herbicides were rather low, the linearity of calibration curve and the precision were good. The developed method is more sensitive and much simpler in sample preparation than previously reported ones. With the established SPME method, a dosed herbicide was successfully separated and determined in rats' blood.  相似文献   

10.
Seasonal changes of field populations and growth rates of two dinoflagellates, Ceratium furca and Ceratium fusus, were examined in the temperate coastal water of Sagami Bay, Japan. Weekly field sampling was conducted from August 2002 to August 2003, and laboratory experiments were also carried out to investigate effects of temperature, irradiance and photoperiod on the growth rates of these two Ceratium species. In the field, the abundances of both species increased significantly from April to August 2003, were gradually decreased from November 2002 and were not observed in January 2003. C. fusus was able to increase at lower temperatures in February 2003 compared to C. furca. In the laboratory, the two species did not grow at <10 °C or >32 °C. The highest specific growth rate of C. furca was 0.72 d−1 at 24 °C and 600 μmol m−2 s−1. Optimum growth rates (>0.4 d−1) of C. furca were observed at temperatures from 18 to 28 °C and at irradiances from 216 to 796 μmol m−2 s−1. The highest growth rate of C. fusus was 0.56 d−1 at 26 °C and 216 μmol m−2 s−1. Optimum growth rates of C. fusus were observed at the same irradiance rage of C. furca, whereas optimum temperature range was narrower (26–28 °C). The growth curves of both species indicated saturation of the growth rates when light intensity was above 216 μmol m−2 s−1, and did not show photoinhibition at irradiances up to 796 μmol m−2 s−1. The specific growth rates of both Ceratium species were clearly decreased at L:D = 10:14 relative to those at L:D = 14:10 and L:D = 12:12. The present study indicates the two Ceratium species can adapt to a wide range of temperature and irradiance.  相似文献   

11.
We have modified gradient HPLC procedures for simultaneous quantification of retinol, γ-tocopherol, α-tocopherol, lutein/zeaxanthin, β-cryptoxanthin, trans-lycopene, cis-lycopene, α-carotene and β-carotene in 200-μl aliquots of human plasma. The photosensitivity of these analytes in plasma exposed to fluorescent lighting for up to 72 h was investigated and most were stable under these conditions. The stability of these analytes held in darkness at −20°C, 4°C or room temperature for up to 48 h after extraction from plasma was also investigated. Variability in measurement of most analytes was greater at room temperature than at 4°C or −20°C. There were statistically significant variations in the measured concentrations of some analytes in samples kept cold. However, the magnitude of these variations was small and of little biological significance, particularly over the first 24 h.  相似文献   

12.
We have established an ultra-sensitive method for determination of ethanol in whole blood by headspace capillary gas chromatography (GC) with cryogenic oven trapping. After heating a blood sample containing ethanol and isobutyl alcohol (internal standard, IS) in a 7.0-ml vial at 55°C for 15 min, 5 ml of the headspace vapor was drawn into a glass syringe and injected into a GC port. All vapor was introduced into an Rtx-BAC2 wide-bore capillary column in the splitless mode at −60°C oven temperature to trap entire analytes, and then the oven temperature was programmed up to 240°C for GC measurements with flame ionization detection. The present method gave sharp peaks of ethanol and IS, and low background noise for whole blood samples. The mean partition into the gaseous phase for ethanol and IS was 3.06±0.733 and 8.33±2.19%, respectively. The calibration curves showed linearity in the range 0.02–5.0 μg/ml whole blood. The detection limit was estimated to be 0.01 μg/ml. The coefficients of intra-day and inter-day variation for spiked ethanol were 8.72 and 9.47%, respectively. Because of the extremely high sensitivity, we could measure low levels of endogenous ethanol in whole blood of subjects without drinking. The concentration of endogenous ethanol measured for 10 subjects under uncontrolled conditions varied from 0 to 0.377 μg/ml (mean, 0.180 μg/ml). Data on the diurnal changes of endogenous ethanol in whole blood of five subjects under strict food control are also presented; they are in accordance with the idea that endogenous blood ethanol is of enteric bacterial origin.  相似文献   

13.
This paper describes a novel liquid chromatographic method for the quantitation of 2-naphthol in human urine. Urine samples were extracted after enzymatic hydrolysis of glucuronides and sulfates; 2-naphthol was then separated using reversed-phase high-performance liquid chromatography. The corresponding detection limits were 0.04 ng/ml for the standard sample in acetonitrile and 0.13 ng/ml for urine samples. The level of urinary 2-naphthol in 100 Korean shipyard workers was analyzed using this new method. The level ranged from 0.21 ng/ml (0.26 μmol/mol creatinine) to 34.19 ng/ml (59.11 μmol/mol creatinine), and the mean±standard deviation was 5.08 ng/ml (6.60 μmol/mol creatinine)±5.75 ng/ml (9.22 μmol/mol creatinine). The mean±standard deviation of urinary 2-naphthol level of smokers, 7.03 ng/ml (8.49 μmol/mol creatinine)±6.16 ng/ml (10.23 μmol/mol creatinine), was significantly higher than that of non-smokers, 2.49 ng/ml (4.10 μmol/mol creatinine)±3.92 ng/ml (7.03 μmol/mol creatinine).  相似文献   

14.
15.
As a part of a pilot clinical study, a high-performance reversed-phase liquid chromatography analysis was developed to quantify temozolomide in plasma and urine of patients undergoing a chemotherapy cycle with temozolomide. All samples were immediately stabilized with 1 M HCl (1 + 10 of biological sample), frozen and stored at −20°C prior to analysis. The clean-up procedure involved a solid-phase extraction (SPE) of clinical sample (100 μl) on a 100-mg C18-endcapped cartridge. Matrix components were eliminated with 750 μl of 0.5% acetic acid (AcOH). Temozolomide was subsequently eluted with 1250 μl of methanol (MeOH). The resulting eluate was evaporated under nitrogen at RT and reconstituted in 200 μl of 0.5% AcOH and subjected to HPLC analysis on an ODS-column (MeOH-0.5% AcOH, 10:90) with UV detection at 330 nm. The calibration curves were linear over the concentration range 0.4–20 μg/ml and 2–150 μg/ml for plasma and urine, respectively. THe extraction recovery of temozolomide was 86–90% from plasma and 103–105% from urine over the range of concentrations considered. The stability of temozolomide was studied in vitro in buffered solutions at RT, and in plasma and urine at 37°C. An acidic pH (<5–6) shoul be maintained throughout the collection, the processing and the analysis of the sample to preserve the integrity of the drug. The method reported here was validated for use in a clinical study of temozolomide for the treatment of metastatic melanoma and high grade glioma.  相似文献   

16.
The present status of the technique to measure concentrations of electrolyte elements and dry mass in 1 μm thick frozen-hydrated sections of soft biological tissues with electron probe X-ray microanalysis in a scanning electron microscope is critically reviewed. The technique is to quench-freeze fresh specimens to < − 180°C, cut 1 μm thick hydrated cryosections −70°C), transfer on to a cold stage (< −170°C) of a suitable microanalytical arrangement, obtain scanning transmission images to identify the cell and tissue compartments, locate an electron probe (several μm2 to 100 nm) on the areas of interest and collect X-ray quanta. The X-ray quanta are collected with suitable spectrometers (WDS and EDS) and processed with a computer using a comprehensive programme based on continuum normalization procedures (‘Hall’ programme). The cryosections are analysed first in a hydrated state and second after dehydration within the microanalyser column to obtain directly elemental concentrations in mM kg−1 wet wt and mM kg−1 dry wt of the compartments identified under the beam. The local water-fractions are estimated and the elemental concentrations converted into mM 1−1 water. In the past 7 years the technique has been applied to obtain fully quantitative information on Na, K, Cl, P, S, Ca and H2O in more than ten types of tissue.  相似文献   

17.
The effects of a synthetic prostaglandin analogue, cloprostenol, on luteal function in a guinea pig were studied. At a dose of 250μg, cloprostenol administered I-P on day 9 of the oestrous cycle caused a reduction in the length of the oestrous cycle from 17.4±s.d. 0.9 to 14.5±1.1 days (p<0.01). Lower doses were ineffective, and post-treatment cycles were not different in length from pre-treatment cycles. Cloprostenol also caused a dose-dependent reduction in luteal weight, which fell from 3.52±0.82 to 1.82±0.4mg (<0.01) 48 h after administation of a 250μg dose on day 9. Plasma progesterone, measured by radioimmunoassay, was reduced from 4.67±0.59 to 2.69±0.66 ng ml−1(p<0.01) 48 h after administration of 250μg cloprostenol on day 9. 250μg cloprostenol also reduced blood flow per corpus luteum, measured by 85Sr-labelled 15μm microspheres, both at 3 h (20.20±10.36 to 9.40±4.2μ1 min−1; p0.05) and at 48 h 18.47±8.27 to 5.23±1.90μl min−1; p<0.01) after administration on day 9. No adverse side-effects were observed at any dose level of cloprostenol used. It was concluded that cloprostenol is a useful experimental luteolysin in the guinea pig.  相似文献   

18.
The kinetics of formation of the complex ion, μ-carbonato-di-μ-hydroxo-bis((1,5-diamino-3-aza-pentane) cobalt(III), from the tri-μ-hydroxo-bis((1,5-diamino-3-aza-pentane(III)cobalt(III)) ion in aqueous buffered carbonate solution have been studied spectrophotometrically at 295 nm over the ranges 20.0θ°C34.8, 8.03pH9.44, 5 mM [CO32−35 mM and at an ionic strength of 0.1 M (LiClO4). On the basis of the kinetic results a mechanism, involving rapid cleavage of an hydroxo bridge followed by carbon dioxide uptake with subsequent bridge formation, has been proposed. At 25 °C, the rate of the carbon dioxide uptake is 0.58 M−1 s−1 with ΔH≠ = (13.2±0.7) kcal mol−1 and ΔS≠ = (−15.1 ± 0.7) cal deg−1 mol−1. The results are composed with those obtained for several mononuclear cobalt(III) and one dinuclear cobalt(III) complexes.  相似文献   

19.
The NAD-dependent glutamate dehydrogenase (GDH) (EC 1.4.1.2) fromLaccaria bicolorwas purified 410-fold to apparent electrophoretic homogeneity with a 40% recovery through a three-step procedure involving ammonium sulfate precipitation, anion-exchange chromatography on DEAE–Trisacryl, and gel filtration. The molecular weight of the native enzyme determined by gel filtration was 470 kDa, whereas sodium dodecyl sulfate–polyacrylamide gel electrophoresis gave rise to a single band of 116 kDa, suggesting that the enzyme is composed of four identical subunits. The enzyme was specific for NAD(H). The pH optima were 7.4 and 8.8 for the amination and deamination reactions, respectively. The enzyme was found to be highly unstable, with virtually no activity after 20 days at −75°C, 4 days at 4°C, and 1 h at 50°C. The addition of ammonium sulfate improved greatly the stability of the enzyme and full activity was still observed after several months at −75°C. NAD-GDH activity was stimulated by Ca2+and Mg2+but strongly inhibited by Cu2+and slightly by the nucleotides AMP, ADP, and ATP. The Michaelis constants for NAD, NADH, 2-oxoglutarate, and ammonium were 282 μM, 89 μM, 1.35 mM, and 37 mM, respectively. The enzyme had a negative cooperativity for glutamate (Hill number of 0.3), and itsKmvalue increased from 0.24 to 3.6 mM when the glutamate concentration exceeded 1 mM. These affinity constants of the substrates, compared with those of the NADP-GDH of the fungus, suggest that the NAD-GDH is mainly involved in the catabolism of glutamate, while the NADP-GDH is involved in the catalysis of this amino acid.  相似文献   

20.
Methylhippuric acid isomers (MHAs), urinary metabolites of xylenes, were determined, after clean-up by C18-SPE and esterification with hexafluoroisopropanol and diisopropylcarbodiimide, by GC with ECD detection, on an SPB-35 capillary column (30 m, 0.32 mm I.D., 0.25 μm film thickness, β=320). S-benzyl-mercapturic acid was used for internal standardization. Chromatographic conditions were: oven temperature 162°C, for 14.2 min; ramp by 30°C/min to 190°C, for 3.5 min; ramp by 30°C/min to 250°C, for 4 min; helium flow rate: 1.7 ml/min; detector and injector temperature: 300°C. The sample (1 μl) was injected with a split injection technique (split ratio 5:1). MHA recovery was >95% in the 0.5–20 μmol/l range; the limit of detection was <0.25 μmol/l; day-to-day precision, at 2 μmol/l, was Cv<10%. Urinary MHAs were determined in subjects exposed to different low-level sources of xylenes: (a) tobacco smoking habit and (b) BTX urban air pollution (airborne xylene ranging from 0.1 to 3.7 μmol/m3). Study (a) showed a significant difference between urinary MHA median excretion values of nonsmokers and smokers (4.6 μmol/l vs. 8.1 μmol/l, p<0.001). Study (b) revealed a significant difference between indoor workers and outdoor workers (4.3 μmol/l vs. 6.9 μmol/l, p<0.001), and evidenced a relationship between MHAs (y, μmol/mmol creatinine) and airborne xylene (x, μmol/m3) (y=0.085+0.34x; r=0.82, p<0.001, n=56). Proposed biomarkers could represent reliable tools to study very low-level exposure to aromatic hydrocarbons such as those observed in the urban pollution due to vehicular traffic or in indoor air quality evaluation.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号