首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 250 毫秒
1.
Superimposition of serial Cone Beam Computed Tomography (CBCT) scans has become a valuable tool for three dimensional (3D) assessment of treatment effects and stability. Voxel based image registration is a newly developed semi-automated technique for superimposition and comparison of two CBCT scans. The accuracy and reproducibility of CBCT superimposition on the anterior cranial base or the zygomatic arches using voxel based image registration was tested in this study. 16 pairs of 3D CBCT models were constructed from pre and post treatment CBCT scans of 16 adult dysgnathic patients. Each pair was registered on the anterior cranial base three times and on the left zygomatic arch twice. Following each superimposition, the mean absolute distances between the 2 models were calculated at 4 regions: anterior cranial base, forehead, left and right zygomatic arches. The mean distances between the models ranged from 0.2 to 0.37 mm (SD 0.08-0.16) for the anterior cranial base registration and from 0.2 to 0.45 mm (SD 0.09-0.27) for the zygomatic arch registration. The mean differences between the two registration zones ranged between 0.12 to 0.19 mm at the 4 regions. Voxel based image registration on both zones could be considered as an accurate and a reproducible method for CBCT superimposition. The left zygomatic arch could be used as a stable structure for the superimposition of smaller field of view CBCT scans where the anterior cranial base is not visible.  相似文献   

2.
We evaluated the absorbed dose to critical organs, as well as the image quality, at different partial angles in kV-CBCT (Cone Beam Computed Tomography) scanning of the head and neck region. CBCT images of phantom from a 200° rotation were performed by using three different scanning paths, anterior, posterior, and right lateral with Catphan504 and RANDO phantoms. Critical organ dose was measured using TLD 100H in the RANDO phantom. The image quality of those phantoms was evaluated, using HU uniformity, HU linearity, contrast-to-noise ratio, low contrast visibility and spatial resolution with the Catphan504 dataset; and 5-point grading scales for the RANDO phantom dataset by five radiation oncologists. The image qualities from Catphan504 and RANDO phantom of every scanning path were comparable, with no statistically significant difference (p ≥ 0.05). However, there was a significant difference in the critical organ dose in all paths (p < 0.05), depending on the critical organ location and the scanning direction. Scanning directions show no effects on the image quality. Differences in absorbed dose to critical organs should were evaluated. The posterior scanning path for the CBCT was deemed preferable due because of considerably lower doses to several critical organs of the head and neck region.  相似文献   

3.

Background

Cone-beam Computed Tomography (CBCT) and stereophotography are two of the latest imaging modalities available for three-dimensional (3-D) visualization of craniofacial structures. However, CBCT provides only limited information on surface texture. This can be overcome by combining the bone images derived from CBCT with 3-D photographs. The objectives of this study were 1) to evaluate the feasibility of integrating 3-D Photos and CBCT images 2) to assess degree of error that may occur during the above processes and 3) to identify facial regions that would be most appropriate for 3-D image registration.

Methodology

CBCT scans and stereophotographic images from 29 patients were used for this study. Two 3-D images corresponding to the skin and bone were extracted from the CBCT data. The 3-D photo was superimposed on the CBCT skin image using relatively immobile areas of the face as a reference. 3-D colour maps were used to assess the accuracy of superimposition were distance differences between the CBCT and 3-D photo were recorded as the signed average and the Root Mean Square (RMS) error.

Principal Findings:

The signed average and RMS of the distance differences between the registered surfaces were −0.018 (±0.129) mm and 0.739 (±0.239) mm respectively. The most errors were found in areas surrounding the lips and the eyes, while minimal errors were noted in the forehead, root of the nose and zygoma.

Conclusions

CBCT and 3-D photographic data can be successfully fused with minimal errors. When compared to RMS, the signed average was found to under-represent the registration error. The virtual 3-D composite craniofacial models permit concurrent assessment of bone and soft tissues during diagnosis and treatment planning.  相似文献   

4.
Cone beam computed tomography (CBCT) is a diverse 3D x-ray imaging technique that has gained significant popularity in dental radiology in the last two decades. CBCT overcomes the limitations of traditional two-dimensional dental imaging and enables accurate depiction of multiplanar details of maxillofacial bony structures and surrounding soft tissues. In this review article, we provide an updated status on dental CBCT imaging and summarise the technical features of currently used CBCT scanner models, extending to recent developments in scanner technology, clinical aspects, and regulatory perspectives on dose optimisation, dosimetry, and diagnostic reference levels. We also consider the outlook of potential techniques along with issues that should be resolved in providing clinically more effective CBCT examinations that are optimised for the benefit of the patient.  相似文献   

5.
Reference scanners are used in dental medicine to verify a lot of procedures. The main interest is to verify impression methods as they serve as a base for dental restorations. The current limitation of many reference scanners is the lack of accuracy scanning large objects like full dental arches, or the limited possibility to assess detailed tooth surfaces. A new reference scanner, based on focus variation scanning technique, was evaluated with regards to highest local and general accuracy. A specific scanning protocol was tested to scan original tooth surface from dental impressions. Also, different model materials were verified. The results showed a high scanning accuracy of the reference scanner with a mean deviation of 5.3 ± 1.1 µm for trueness and 1.6 ± 0.6 µm for precision in case of full arch scans. Current dental impression methods showed much higher deviations (trueness: 20.4 ± 2.2 µm, precision: 12.5 ± 2.5 µm) than the internal scanning accuracy of the reference scanner. Smaller objects like single tooth surface can be scanned with an even higher accuracy, enabling the system to assess erosive and abrasive tooth surface loss. The reference scanner can be used to measure differences for a lot of dental research fields. The different magnification levels combined with a high local and general accuracy can be used to assess changes of single teeth or restorations up to full arch changes.  相似文献   

6.
Stereotactic Body Radiation Therapy (SBRT), alternatively termed Stereotactic ABlative Radiotherapy (SABR) or Stereotactic RadioSurgery (SRS), delivers high dose with a sub-millimeter accuracy. It requires meticulous precautions on positioning, as sharp dose gradients near critical neighboring structures (e.g. the spinal cord for spinal tumor treatment) are an important clinical objective to avoid complications such as radiation myelopathy, compression fractures, or radiculopathy. To allow for dose escalation within the target without compromising the dose to critical structures, proper immobilization needs to be combined with (internal) motion monitoring. Metallic fiducials, as applied in prostate, liver or pancreas treatments, are not suitable in clinical practice for spine SBRT. However, the latest advances in Deep Learning (DL) allow for fast localization of the vertebrae as landmarks. Acquiring projection images during treatment delivery allows for instant 2D position verification as well as sequential (delayed) 3D position verification when incorporated in a Digital TomoSynthesis (DTS) or Cone Beam Computed Tomography (CBCT). Upgrading to an instant 3D position verification system could be envisioned with a stereoscopic kilovoltage (kV) imaging setup. This paper describes a fast DL landmark detection model for vertebra (trained in-house) and evaluates its accuracy to detect 2D motion of the vertebrae with the help of projection images acquired during treatment. The introduced motion consists of both translational and rotational variations, which are detected by the DL model with a sub-millimeter accuracy.  相似文献   

7.
The analysis of palatal vault morphology and maxillary dental arch shape was carried out in the sample of 42 Down syndrome (DS) patients with trisomy 21. The data were compared to those of healthy controls from the same population matched for age and sex. Palatal morphology and upper dental arch shape were studied on hard plaster casts of the patients and controls. No sexual dimorphism in palatal and dental arch shape was observed in DS and controls. Normal palatal shape was more frequent in controls than in DS subjects (52.38% vs. 28.57%; p < 0.05). DS patients displayed significantly higher frequency of shelf-like or "stair palate" (38.1%) than controls (11.9%) (p < 0.02). The younger age group (3-14 year) showed much higher frequency of "stair palate" than controls (26.19% vs. 2.38%; c2 = 9.72; p = 0.003). The older group of DS patients did not show increased frequency of such shape of the palatal vault. There was no significant difference in dental arch shape between DS patients and controls. High frequency of shelf-like palate in DS subjects is decreasing by age. The obtained results indicate that palatal vault morphology is subjected to the age related changes. These changes can be attributed to the growth of caraniofacial structures and increased tonus of tongue and other orofacial muscles.  相似文献   

8.

Purpose

Scatter is a very important artifact causing factor in dental cone-beam CT (CBCT), which has a major influence on the detectability of details within images. This work aimed to improve the image quality of dental CBCT through scatter correction.

Methods

Scatter was estimated in the projection domain from the low frequency component of the difference between the raw CBCT projection and the projection obtained by extrapolating the model fitted to the raw projections acquired with 2 different sizes of axial field-of-view (FOV). The function for curve fitting was optimized by using Monte Carlo simulation. To validate the proposed method, an anthropomorphic phantom and a water-filled cylindrical phantom with rod inserts simulating different tissue materials were scanned using 120 kVp, 5 mA and 9-second scanning time covering an axial FOV of 4 cm and 13 cm. The detectability of the CT image was evaluated by calculating the contrast-to-noise ratio (CNR).

Results

Beam hardening and cupping artifacts were observed in CBCT images without scatter correction, especially in those acquired with 13 cm FOV. These artifacts were reduced in CBCT images corrected by the proposed method, demonstrating its efficacy on scatter correction. After scatter correction, the image quality of CBCT was improved in terms of target detectability which was quantified as the CNR for rod inserts in the cylindrical phantom.

Conclusions

Hopefully the calculations performed in this work can provide a route to reach a high level of diagnostic image quality for CBCT imaging used in oral and maxillofacial structures whilst ensuring patient dose as low as reasonably achievable, which may ultimately make CBCT scan a reliable and safe tool in clinical practice.  相似文献   

9.
Computed Tomography (Electron Beam Tomography: EBCT and multislice computed tomography: MSCT) have recently emerged as non-invasive diagnostic modalities that can quantify coronary calcium which is not only as indicator of coronary risk, but also permits assessment of the coronary lumen. The 16-slice MS-CT, the most recent CT-scanner has a very high resolution, which allows non-invasive assessment of coronary plaques. This has led to a stimulus for further research to assess the role of MSCT coronary plaque imaging in the identification of high-risk coronary plaques.  相似文献   

10.
This paper presents the details and logic of a Fortran computer program which carries out routine clinical analysis of dental models resulting from impressions of the teeth and related structures, which are subsequently cast in plaster of Paris. The program is primarily intended for use by the orthodontist who is engaged in research or clinical practice, and is useful in studies related to changes in the dentition as a result of orthodontic treatment.  相似文献   

11.
AimTo review the recent evolution of spine SBRT with emphasis on single dose treatments.BackgroundRadiation treatment of spine metastases represents a challenging problem in clinical oncology, because of the high risk of inflicting damage to the spinal cord. While conventional fractionated radiation therapy still constitutes the most commonly used modality for palliative treatment, notwithstanding its efficacy in terms of palliation of pain, local tumor control has been approximately 60%. This limited effectiveness is due to previous lack of technology to precisely target the tumor while avoiding the radiosensitive spinal cord, which constitutes a dose-limiting barrier to tumor cure.Materials and methodsA thorough review of the available literature on spine SBRT has been carried out and critically assessed.ResultsStereotactic body radiotherapy (SBRT) emerges as an alternative, non-invasive high-precision approach, which allows escalation of tumor dose, while effectively sparing adjacent uninvolved organs at risk. Engaging technological advances, such as on-line Cone Beam Computed Tomography (CBCT), coupled with Dynamic Multi-Leaf Collimation (DMLC) and rapid intensity-modulated (IMRT) beam delivery, have promoted an interactive image-guided (IGRT) approach that precisely conforms treatment onto a defined target volume with a rapid dose fall-off to collateral non-target tissues, such as the spinal cord. Recent technological developments allow the use of the high-dose per fraction mode of hypofractionated SBRT for spinal oligometastatic cancer, even if only a few millimeters away from the tumor.ConclusionSingle-dose spine SBRT, now increasingly implemented, yields unprecedented outcomes of local tumor ablation and safety, provided that advanced technology is employed.  相似文献   

12.
The purpose of this investigation was to establish general trends of intra-group variations in the dental eruption sequence of a semi-wild troop of Maca fuscata fuscata. Dental impressions were taken on 128 animals of varying ages. The analysis of the dental casts revealed sexual dimorphism in sequence and timing of eruption.  相似文献   

13.
This study compared the capabilities of micro-computed tomography (micro-CT) and dental cone-beam computed tomography (CBCT) in assessing trabecular bone parameters and cortical bone strength. Micro-CT and CBCT scans were applied to 28 femurs from 14 rats to obtain independent measurements of the volumetric cancellous bone mineral density (vCanBMD) in the femoral head, volumetric cortical bone mineral density (vCtBMD) in the femoral diaphysis, cross-sectional moment of inertia (CSMI), and bone strength index (BSI) (=CSMI×vCtBMD). Five structural parameters of the trabecular bone of the femoral head were calculated from micro-CT images. A three-point bending test was then conducted to measure the fracture load of each femur. Bivariate linear Pearson analysis was conducted to calculate the correlation coefficients (r values) of the micro-CT, dental CBCT, and three-point bending measurements. The statistical analyses showed a strong correlation between vCanBMD values obtained using micro-CT and dental CBCT (r=0.830). There were strong or moderate correlation between vCanBMD measured using dental CBCT and five parameters of trabecular structure measured using micro-CT. Additionally, the results were satisfactory regardless of whether micro-CT or dental CBCT was used to measure the femoral diaphysis vCtBMD (r=0.733 and 0.680, respectively), CSMI (r=0.756 and 0.726, respectively), or BSI (r=0.846 and 0.847, respectively) to predict fracture loads. This study has yielded a new method for using dental CBCT to evaluate bone parameters and bone strength; however, further studies are necessary to validate the use of dental CBCT on humans.  相似文献   

14.
PurposeKilovoltage flat-panel imaging systems are used for cone-beam Computed Tomography (CBCT) and digital Tomosynthesis (DTS). Hereby, the presence of scatter and relatively large dose from imaging are challenging factors. In this study a phenomenological beam model was developed to characterize imager response to imaging beams with a bow-tie filter (Varian OBI system).Materials and methodThe kilovoltage beam model was based on dose ratio formalism and thus was using standard concepts of megavoltage dose calculation such as scatter factors, tissue maximum ratio and off-axis ratio. Primary and scatter (head and phantom scatter) were modeled with three Gaussian kernels. Parameters were based on measured transmission images for slabs of solid water of different total thickness and various jaw settings.ResultsThe beam model was used to evaluate contributions from primary, secondary and tertiary contributions for different geometrical objects such as cylinders and step-like phantoms. Theoretical predictions of radiographs using the model for known objects are consistent with the measurements.ConclusionSecondary and tertiary contributions were interpreted as scatter and can be subtracted from CBCT projections based on the analytical model. Therefore our model can provide a basis for improvement of image quality (less artifacts due to scatter, better contrast and resolution) in CBCT reconstruction.  相似文献   

15.

Introduction

This article reports experience relating to the measurement of orbital volume by means of cone beam computed tomography (CBCT) and Cranioviewer program software in patients who have undergone enucleation and orbital implantation.

Patients and Methods

CBCT scans were made in 30 cases, 10 of which were later excluded because of various technical problems. The study group therefore consisted of 20 patients (8 men and 12 women). The longest follow-up time was 7 years, and the shortest was 1 year. In all 20 cases, the orbital volume was measured with Cranioviewer orbital program software. Slices were made in the ventrodorsal direction at 4.8 mm intervals in the frontal plane, in both bony orbits (both that containing the orbital implant and the healthy one). Similar measurements were made in 20 patients with various dental problems. CBCT scans were recorded for the facial region of the skull, containing the orbital region. The Cranioviewer program can colour the area of the slices red, and it automatically measures the area in mm.

Results

In 5 of the 20 cases, the first 4 or all 5 slices revealed that the volume of the operated orbit was significantly smaller than that of the healthy orbit, in 12 cases only from 1 to 3 of the slices indicated such a significant difference, and in 3 cases no differences were observed between the orbits. In the control group of patients with various dental problems, there was no significant difference between the two healthy orbits. The accuracy of the volume measurements was assessed statistically by means of the paired samples t-test.

Summary

To date, no appropriate method is avaliable for exact measurement of the bony orbital volume, which would be of particular importance in orbital injury reconstruction. However, the use of CBCT scans and Cranioviewer orbital program software appears to offer a reliable method for the measurement of changes in orbital volume.  相似文献   

16.
A method for measuring three-dimensional kinematics that incorporates the direct cross-registration of experimental kinematics with anatomic geometry from Computed Tomography (CT) data has been developed. Plexiglas registration blocks were attached to the bones of interest and the specimen was CT scanned. Computer models of the bone surface were developed from the CT image data. Determination of discrete kinematics was accomplished by digitizing three pre-selected contiguous surfaces of each registration block using a three-dimensional point digitization system. Cross-registration of bone surface models from the CT data was accomplished by identifying the registration block surfaces within the CT images. Kinematics measured during a biomechanical experiment were applied to the computer models of the bone surface. The overall accuracy of the method was shown to be at or below the accuracy of the digitization system used. For this experimental application, the accuracy was better than +/-0.1mm for position and 0.1 degrees for orientation for linkage digitization and better than +/-0.2mm and +/-0.2 degrees for CT digitization. Surface models of the radius and ulna were constructed from CT data, as an example application. Kinematics of the bones were measured for simulated forearm rotation. Screw-displacement axis analysis showed 0.1mm (proximal) translation of the radius (with respect to the ulna) from supination to neutral (85.2 degrees rotation) and 1.4mm (proximal) translation from neutral to pronation (65.3 degrees rotation). The motion of the radius with respect to the ulna was displayed using the surface models. This methodology is a useful tool for the measurement and application of rigid-body kinematics to computer models.  相似文献   

17.
运用数字总线技术实现多模块化控制,对CT或X光片、口腔数字化扫描仪、印模扫描图像等进行三维重建、立体构图,开发系列规划软件,为口腔医生提供优化治疗、修复方案。同时,计算机可联接微型CAD/CAM自动进行义齿、贴面快速加工,以及种植导板等产品的设计、加工;联接手术导航仪进行牙种植手术导航;联接PACS、HIS等系统,实现数字化图像传输以及远程医疗功能。在诊所内一体化完成诊断、治疗、制作、修复、整形、美容等系列复杂、精细工作。  相似文献   

18.
A Spiral Computerized Tomography (CT) scan of the aorta were obtained from a single subject and three model variations were examined. Computational fluid dynamics modeling of all three models showed variations in the velocity contours along the aortic arch with differences in the boundary layer growth and recirculation regions. Further down-stream, all three models showed very similar velocity profiles during maximum velocity with differences occurring in the decelerating part of the pulse. Flow patterns obtained from transient 3-D computational fluid dynamics are influenced by different reconstruction methods and the pulsatility of the flow. Caution is required when analyzing models based on CT scans.  相似文献   

19.
Examination for incidence of Carabelli's trait was done on 1267 Africans and 781 Asian school children, 298 dental plaster casts and 248 skulls of Africans. The African sample is composed of 80% Bantu, 20% Nilote, and Nilo-Hamitic people. When observed intraorally, the trait is present in 31–35% of Africans and 26–27% of Asians. In the dental casts and skull sample of Africans, the trait is present as pit in 23–28%, groove in 20%, and as tubercle and cusp in 22%. The total trait frequency in Africans is 68%.  相似文献   

20.
The objective of this study is to determine the prevalence of expression and bilateralism of two dental morphological traits in contemporary Jordanians: The hypocone reduction trait on the maxillary second permanent molar and Carabelli's trait on maxillary permanent first and second molars. Furthermore, inter-trait correlation and the relationship of Carabelli's traits with upper first molar dimensions were investigated. Three hundred subjects of school children at their 10th grade and of an average age of 15.5 +/- 0.4 years were involved. Alginate impressions for the maxillary arch were taken, dental casts were reproduced. The selected accurate casts were of 132 male- and 155 female-students. The frequencies of hypocone reduction trait on the maxillary second molar and Carabelli's trait on the maxillary molars were examined. Buccolingual and mesiodistal diameters of the maxillary first molar were measured and recorded. Paired Sample t test and Nonparametric Correlation analysis were used for data analysis. Hypocone reduction trait on the maxillary second molar was found in 29.8% of the examined students. Positive forms of Carabelli's trait on first and second molars were observed in 65.0% and 3.8%, respectively. Nonparametric correlation analysis revealed positive association between Carabelli's trait on first molar and hypocone reduction trait on the maxillary second molar. The presence of Carabelli's trait on first molar was strongly associated with the increase of buccolingual, but not the mesiodistal, diameter. Bilateralism was found highly significant in the tested traits and both genders (p < 0.001). This finding might be a sign of relatively low environmental stresses in the living Jordanian population and/or great ability of its individuals to buffer the adverse effects of such stresses.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号