首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The mechanomyogram (MMG) is a signal measured by various vibration sensors for slight vibrations induced by muscle contraction, and it reflects the muscle force during electrically induced-contraction or until 60%–70% maximum voluntary contraction, so the MMG is considered an alternative and novel measurement tool for muscle strength. We simultaneously measured the MMG and muscle force in the gastrocnemius (GC), vastus intermedius (VI), and soleus (SOL) muscles of rats. The muscle force was measured by attaching a hook to the tendon using a load cell, and the MMG was measured using a charged-coupled device-type displacement sensor at the middle of the target muscle. The MMG-twitch waveform was very similar to that of the muscle force; however, the half relaxation time and relaxation time (10%), which are relaxation parameters, were prolonged compared to those of the muscle force. The MMG amplitude correlated with the muscle force. Since stimulation frequencies that are necessary to evoke tetanic progression have a significant correlation with the twitch parameter, there is a close relationship between twitch and tetanus in the MMG signal. Therefore, we suggest that the MMG, which is electrically induced and detected by a laser displacement sensor, may be an alternative tool for measuring muscle strength.  相似文献   

2.
The purpose of the present study was to assess the ability of TMG in detecting mechanical fatigue induced by two different resistance exercises on biceps brachii: high-volume (HV), and high-load (HL). Sixteen healthy subjects (age 25.1±2.6years; body mass 79.9±8.9kg; height 179±7.4cm) performed arm-curl in two different protocols (HV: 8×15×10kg, HL: 5×3×30kg). Tensiomyography was used to assess muscle response to both exercise protocols. The contractile capacity of biceps brachii significantly varied by means of the effects of potentiation and fatigue mechanisms that take place at different exercise phases. The most significant changes correspond to values of maximum radial displacement of muscle belly (D(m)), sustained contraction time (T(s)), relaxation time (T(r)), and contraction velocity (V(c)). The behavior of these parameters is, in general, similar in both exercise protocols, but they show subtle differences among them. During the first set, in both protocols, values for V(c) increase, along with a decrease in T(r), T(s), and D(m) values. Fatigue onset was evident from changes in such parameters, with HL being the first in showing these mechanisms. Tensiomyography has been shown to be highly sensitive in detecting fatigue-induced changes.  相似文献   

3.
Tensiomyography (TMG) is a relatively novel technique to assess muscle mechanical response based on radial muscle belly displacement consecutive to a single electrical stimulus. Although intra-session reliability has been found to be good, inter-rater reliability and the influence of sensor repositioning and electrodes placement on TMG measurements is unknown. The purpose of this study was to analyze the inter-rater reliability of vastus medialis muscle contractile property measurements obtained with TMG as well as the effect of inter-electrode distance (IED). Five contractile parameters were analyzed from vastus medialis muscle belly displacement–time curves: maximal displacement (Dm), contraction time (Tc), sustain time (Ts), delay time (Td), and half-relaxation time (Tr). The inter-rater reliability and IED effect on these measurements were evaluated in 18 subjects. Intra-class correlation coefficients, standard errors of measurement, Bland and Altman systematic bias and random error as well as coefficient of variations were used as measures of reliability. Overall, a good to excellent inter-rater reliability was found for all contractile parameters, except Tr, which showed insufficient reliability. Alterations in IED significantly affected Dm with a trend for all the other parameters. The present results legitimate the use of TMG for the assessment of vastus medialis muscle contractile properties, particularly for Dm and Tc. It is recommended to avoid Tr quantification and IED modifications during multiple TMG measurements.  相似文献   

4.
INTRODUCTION: The repeatability of subjective and objective assessments of neck muscle fatigue is very important with regard to the clinical applicability of these methods. METHOD: To establish between-days reliability, 33 healthy volunteers performed a 60% maximum voluntary isometric contraction test from a standing position in all neck movements. Cervical muscle fatigue was assessed on three separate occasions from the spectral (median frequency, MF) and amplitude (root mean square, RMS) analysis of the electromyogram (EMG) signal recorded from the cervical paraspinal group, splenius capitis, levator scapulae and sternocleidomastoid. Subjective assessment of fatigue was rated by employing the Borg scale. Intraclass correlation coefficient ICC((1,1)), standard error of measurement (SEM), smallest detectable difference (SDD) indices and Pearson's correlation co-efficient were calculated for the analysis of the results. RESULTS: Normalised median frequency (MF) slope had low repeatability and large between-day error (ICC((1,1))=0.28-0.61; SEM=0.33-0.60%/s; SDD=132.7-703.2%) for the protagonist muscles of each movement. Initial median frequency (IMF) had moderate to good reliability and small error (ICC((1,1))=0.64-0.81; SEM=2.8-8.8Hz; SDD=19.9-38.5%). The RMS slope yielded also poor repeatability. The Borg assessment was more reliable than the EMG estimate though variability between sessions was still quite high (SDD=29.2-136.5%). No correlation was found between the EMG and Borg assessment of neck muscle fatigue (r=-0.01-0.39). CONCLUSION: The protocol used for assessing neck muscle fatigue proved to be reliable only for the IMF but the clinical usefulness of this measure remains questionable. The lack of correlation between objective and subjective estimation of neck muscle fatigue was possibly a consequence of the poor measurement repeatability. Further research is needed to identify the factors responsible for these results on neck area.  相似文献   

5.
A computer controlled equipment is described for computer analysis of isometric contractions of cardiac muscle by different modes of excitation. Both the method and the programme are presented. The following parameters are analysed: half and full contraction time, half relaxation time, maximum force developed during contraction, maximum rate of force development. The same computer is simultaneously used for controlling the stimulation.  相似文献   

6.
The repeatability of initial values and rate of change of EMG signal mean spectral frequency (MNF), average rectified values (ARV), muscle fiber conduction velocity (CV) and maximal voluntary contraction (MVC) was investigated in the vastus medialis obliquus (VMO) and vastus lateralis (VL) muscles of both legs of nine healthy male subjects during voluntary, isometric contractions sustained for 50 s at 50% MVC. The values of MVC were recorded for both legs three times on each day and for three subsequent days, while the EMG signals have been recorded twice a day for three subsequent days. The degree of repeatability was investigated using the Fisher test based upon the ANalysis Of VAriance (ANOVA), the Standard Error of the Mean (SEM) and the Intraclass Correlation Coefficient (ICC).

Data collected showed a high level of repeatability of MVC measurement (normalized SEM from 1.1% to 6.4% of the mean). MNF and ARV initial values also showed a high level of repeatability (ICC>70% for all muscles and legs except right VMO). At 50% MVC level no relevant pattern of fatigue was observed for the VMO and VL muscles, suggesting that other portions of the quadriceps might have contributed to the generated effort. These observations seem to suggest that in the investigation of muscles belonging to a multi-muscular group at submaximal level, the more selective electrically elicited contractions should be preferred to voluntary contractions.  相似文献   


7.
Tensiomyography is a method for valid and non-invasive estimation of skeletal muscle fibre type composition. The validity of selected temporal tensiomyographic measures has been well established recently; there is, however, no evidence regarding the method's between-day reliability. Therefore it is the aim of this paper to establish the between-day repeatability of tensiomyographic measures in three skeletal muscles. For three consecutive days, 10 healthy male volunteers (mean±SD: age 24.6 ± 3.0 years; height 177.9 ± 3.9 cm; weight 72.4 ± 5.2 kg) were examined in a supine position. Four temporal measures (delay, contraction, sustain, and half-relaxation time) and maximal amplitude were extracted from the displacement-time tensiomyogram. A reliability analysis was performed with calculations of bias, random error, coefficient of variation (CV), standard error of measurement, and intra-class correlation coefficient (ICC) with a 95% confidence interval. An analysis of ICC demonstrated excellent agreement (ICC were over 0.94 in 14 out of 15 tested parameters). However, lower CV was observed in half-relaxation time, presumably because of the specifics of the parameter definition itself. These data indicate that for the three muscles tested, tensiomyographic measurements were reproducible across consecutive test days. Furthermore, we indicated the most possible origin of the lowest reliability detected in half-relaxation time.  相似文献   

8.
The purpose of this study was to determine test-retest reliability for median frequency (MDF) and amplitude of surface EMG during sustained fatiguing contractions of the quadriceps. Twenty-two healthy subjects (11 males and 11 females) were tested on two days held one week apart. Surface EMG was recorded from rectus femoris (RF), vastus lateralis (VL) and vastus medialis (VM) during sustained isometric contractions at 80% and 20% of maximal voluntary contraction (MVC) held to exhaustion. Quadriceps fatigue was described using four measures for both MDF and amplitude of EMG: initial, final, normalized final and slope. For both MDF and amplitude, the initial, final and normalized EMG showed moderate to high reliability for all three muscle groups at both contraction levels (ICC=0.59-0.88 for MDF; ICC=0.58-0.99 for amplitude). Slope of MDF and amplitude was associated with a large degree of variability and low ICCs for the 80% but not the 20% MVC. MDF and amplitude of EMG during sustained contractions of the quadriceps are reproducible; normalized final values of MDF and amplitude show better reliability than slope.  相似文献   

9.
This study assessed muscle fatigue patterns of the elbow flexors in untrained men and women to determine if sex differences exist during acute maximal eccentric exercise. High-intensity eccentric exercise is often used by athletes to elicit gains in muscle strength and size gains. Development of fatigue during this type of exercise can increase risk of injury; therefore, it is important to understand fatigue patterns during eccentric exercise to minimize injury risk exposure while still promoting training effects. While many isometric exercise studies have demonstrated that women show less fatigue, the patterns of fatigue during purely eccentric exercise have not been assessed in men and women. Based on the lack of sex differences in overall strength loss immediately post-eccentric exercise, it was hypothesized that women and men would have similar relative fatigue pattern responses (i.e., change from baseline) during a single bout of maximal eccentric exercise. Forty-six subjects (24 women and 22 men) completed 5 sets of 10 maximal eccentric contractions on an isokinetic dynamometer. Maximal voluntary isometric contraction strength was assessed at baseline and immediately following each exercise set. Maximal eccentric torque and contractile properties (i.e., contraction time, work, half relaxation time, and maximal rate of torque development) were calculated for each contraction. Men and women demonstrated similar relative isometric (32% for men and 39% for women) and eccentric (32% for men and 39% for women) fatigue as well as similar deficits in work done and rates of torque development and relaxation during exercise (p > 0.05). Untrained men and women displayed similar relative responses in all measures of muscle function during a single bout of maximal eccentric exercise of the elbow flexors. Thus, there is no reason to suspect that women may be more vulnerable to fatigue-related injury.  相似文献   

10.
The purpose of this study was to compare a piezoelectric contact sensor with an accelerometer for measuring the mechanomyographic (MMG) signal from the biceps brachii during submaximal to maximal isokinetic and isometric forearm flexion muscle actions. Following determination of isokinetic peak torque (PT) and the isometric maximum voluntary contraction (MVC), 10 adults (mean+/-SD age=22.8+/-2.7yrs) performed randomly ordered, submaximal step muscle actions of the dominant forearm flexors in 20% increments from 20% to 80% PT and MVC. Surface MMG signals were recorded simultaneously from a contact sensor and an accelerometer placed over the belly of the biceps brachii muscle. During the isokinetic and isometric muscle actions, the contact sensor and accelerometer resulted in linear increases in normalized MMG amplitude with torque (r(2) range=0.84-0.97) but the linear slope of the normalized MMG amplitude versus isokinetic torque relationship for the accelerometer was less (p<0.10) than that of the contact sensor. There was no significant (p>0.05) relationship for normalized MMG mean power frequency (MPF, %max) versus isokinetic and isometric torque for the contact sensor, but the accelerometer demonstrated a quadratic (R(2)=0.94) or linear (r(2)=0.83) relationship for the isokinetic and isometric muscle actions, respectively. There were also a number of significant (p<0.05) mean differences between the contact sensor and accelerometer for normalized MMG amplitude or MPF values. These findings indicated that in some cases involving dynamic and isometric muscle actions, the contact sensor and accelerometer resulted in different torque-related responses that may affect the interpretation of the motor control strategies involved.  相似文献   

11.
The contraction and relaxation times of the twitches and the last contractions within 32 unfused tetani of FF and 27 unfused tetani of FR motor units in the rat medial gastrocnemius muscle were studied during prolonged activity. The pattern of the MU stimulation included single pulses (to evoke twitches) and series of three trains of stimuli at 40, 50 and 60 Hz (to evoke unfused tetani), repeated 30 times. The analysis concerned changes of force and time parameters at the beginning of activity, during the potentiation and then during the fatigue. It was found that changes of force during the potentiation and the fatigue were mainly accompanied by changes in the course of relaxation. The significant prolongation of the half-relaxation time during the potentiation of either twitches or unfused tetani was revealed in both types of fast MU. The twitch contraction time did not change markedly, whereas significantly shortened in the last contractions of unfused tetani during the potentiation. These changes of time parameters correlated to the increase of the fusion degree. During the fatigue, the time parameters shortened, however, changes of the half-relaxation times were remarkably higher. The shortening of relaxation was responsible for the decrease of the fusion degree. Changes of the fusion index exceeding 0.75 during the potentiation or decreasing below this value during the fatigue, were accompanied by respective appearance or disappearance of the biphasic relaxation.  相似文献   

12.
The repeatability of initial value and rate of change of mean spectral frequency (MNF), average rectified values (ARV) and muscle fiber conduction velocity (CV) was investigated in the dominant biceps brachii of ten normal subjects during sustained isometric voluntary contractions. Four levels of contraction were studied: 10%, 30%, 50% and 70% of the maximal voluntary contraction level (MVC). Each contraction was repeated three times in each of three different days for a total of nine contractions/level/subject and 90 contractions per level across the ten subjects. Repeatability was investigated using the Intraclass Correlation Coefficient (ICC) and the standard error of the mean (SEM) of the estimates for each subject. Contrary to observations in other muscles, CV estimates appeared to be very repeatable both within and between subjects. CV showed a small but significant increase when contraction force increased from 10% to 50% MVC but no change for further increase of force. As force increased, MNF showed a slight decrease possibly related to a wider spreading of the CV values. The rate of time decrement of MNF and CV increased with the level of contraction. The normalized decrement (% of initial value per second) was in general higher for MNF than for CV and was more repeatable between subjects at 10% MVC than at 70% MVC. A final observation is that a resting time of 5 minutes may not be sufficient after a contraction at 50% or 70% MVC.  相似文献   

13.
Muscle function in children   总被引:1,自引:0,他引:1  
Electrically evoked mechanical and contractile properties of the triceps surae have been measured in 52 children aged 11 and 14 years, and results compared with previously reported data for adults (Davies and White 1982). The results show that the time to peak tension (TPT), half relaxation time (1/2RT) and supramaximal tension (Pt) of the twitch were not significantly (P greater than 0.1) different in girls and boys and independent of age. The 14-year-old girls and boys were stronger in terms of their supramaximal 10, 20, and 50 Hz tetanic tensions and maximal voluntary contraction (MVC) than their younger counterparts, and both groups of children were significantly (P less than 0.001) weaker than the young adults. However, if standardisation was made for an anthropometric estimate of calf muscle (plus bone) cross-sectional area (CSA), the differences in strength disappeared. Electrically stimulated and voluntary maximal force per unit CSA measured at the knee were 17.1 and 20.5 N X cm2 respectively and independent of sex and age. The loss of force during a 2-min stimulated fatigue test was the same in the children as the adults. The average fatigue indices ranged from 0.52 to 0.72 in the children, compared with 0.68 in the adults. It is concluded that absolute differences in muscle strength in children are a function of muscle mass. The force generating capacity expressed in N X cm2, fatiguability, contraction and relaxation times of the triceps surae would appear to remain unchanged through adolescence and early adulthood.  相似文献   

14.
Effect of low chloride on relaxation in hamster diaphragm muscle   总被引:1,自引:0,他引:1  
With muscle fatigue the chloride (Cl-) conductance of the sarcolemmal membrane decreases. The role of lowered Cl- conductance in the prolongation of relaxation seen with fatigue was studied in isolated hamster diaphragm strips. The muscles were studied in either a Krebs solution or a low Cl- solution in which half of the NaCl was replaced by Na-gluconate. Short tetanic contractions were produced by a 160-ms train of 0.2-ms pulses at 60 Hz from which tension (T) and the time constant of relaxation were measured. Resting membrane potential (Em) was measured using KCl-filled microelectrodes with resistances of 15-20 M omega. Mild fatigue (20% fall in tension) was induced by 24-25 tetanic contractions at the rate of 2/s. There was no difference in Em or T in the two solutions, either initially or with fatigue. The time constant of relaxation was greater in low Cl- solution, both initially (22 +/- 3 vs. 18 +/- 5 ms, mean +/- SD, P less than 0.05) and with fatigue (51 +/- 18 vs. 26 +/- 7 ms, P less than 0.005). Lowering of sarcolemmal membrane Cl- conductance appears to play a role in the slowing of relaxation of hamster diaphragm muscle seen with fatigue.  相似文献   

15.
Synopsis Latent period, rise time, contraction time, and half relaxation time from isotonic contractions of isolated white muscle samples from skipjack tuna, Katsuwonus pelamis, were determined at 20°, 27°, and 34° C. These parameters were found to be inversely proportional to temperature (Q10 = 1.47, 1.67, 1.62, and 1.72, respectively). The data show that contraction time and the effect of temperature on contraction time of skipjack tuna white muscle are not unique when compared to other equal-sized teleosts. Based on contraction time, maximum swimming speeds at each muscle temperature were calculated and found not significantly to exceed the maximum speeds of other equal-sized teleosts, when comparisons are made at the same white muscle temperatures  相似文献   

16.
The purpose of this study was to comprehensively evaluate the reliability of a large number of commonly utilized experimental tests of in vivo human neuromuscular function separated by 4-weeks. Numerous electrophysiological parameters (i.e., voluntary and evoked electromyogram [EMG] signals), contractile properties (i.e., evoked forces and rates of force development and relaxation), muscle morphology (i.e., MRI-derived cross-sectional area [CSA]) and performance tasks (i.e., steadiness and time to task failure) were assessed from the plantarflexor muscle group in 17 subjects before and following 4-weeks where they maintained their normal lifestyle. The reliability of the measured variables had wide-ranging levels of consistency, with coefficient of variations (CV) ranging from approximately 2% to 20%, and intraclass correlation coefficients (ICC) between 0.53 and 0.99. Overall, we observed moderate to high-levels of reliability in the vast majority of the variables we assessed (24 out of the 29 had ICC>0.70 and CV<15%). The variables demonstrating the highest reliability were: CSA (ICC=0.93-0.98), strength (ICC=0.97), an index of nerve conduction velocity (ICC=0.95), and H-reflex amplitude (ICC=0.93). Conversely, the variables demonstrating the lowest reliability were: the amplitude of voluntary EMG signal (ICC=0.53-0.88), and the time to task failure of a sustained submaximal contraction (ICC=0.64). Additionally, relatively little systematic bias (calculated through the limits of agreement) was observed in these measures over the repeat sessions. In conclusion, while the reliability differed between the various measures, in general it was rather high even when the testing sessions are separated by a relatively long duration of time.  相似文献   

17.
The effect of creatine and caffeine supplementation on muscle torque generation and relaxation was investigated in healthy male volunteers. Maximal torque (T(max)), contraction time (CT) from 0.25 to 0.75 of T(max), and relaxation time (RT) from 0.75 to 0.25 of T(max) were measured during an exercise test consisting of 30 intermittent contractions of musculus quadriceps (2 s stimulation, 2 s rest) that were induced by electrical stimulation. According to a double-blind randomized crossover design, subjects (n = 10) performed the exercise test before (pretest) and after (posttest) creatine supplementation (Cr, 4 x 5 g/day, 4 days), short-term caffeine intake (Caf, 5 mg x kg(-1) x day(-1), 3 days), creatine supplementation + short-term caffeine intake (Cr+Caf), acute caffeine intake (ACaf, 5 mg/kg) or placebo. Compared with placebo, Cr shortened RT by approximately 5% (P < 0.05). Conversely, Caf increased RT (+ approximately 10%, P < 0.05), in particular as RT increased because of fatigue. RT was not significantly changed by either Cr+Caf or ACaf. T(max) and CT were similar during all experimental conditions. Initial T(max) was approximately 20% of voluntary maximal isometric contraction force, which was not different between treatments. It is concluded that Caf intake (3 days) prolongs muscle RT and by this action overrides the shortening of RT due to creatine supplementation.  相似文献   

18.
Changes in electromyographic (EMG) parameters are used to evaluate timing, amplitude, and fatigue of muscle actions during movement. Little published data describe the reliability and precision of multiple EMG parameters, how these parameters compare to one another, and how these parameters vary between muscles. The purpose of this study was to determine the reliability and precision of four EMG parameters recorded from the legs, torso, and arm muscles during running. Fifteen well-trained male runners performed moderate-intensity treadmill running while EMG data were collected from thirteen muscles. Integrated EMG (iEMG), root mean square EMG (RMS), maximum M-wave, and median power frequency (MPF) were calculated for 25 consecutive strides. Intra-class correlation coefficients (ICC) and standard error of measurement (SEM) for each parameter were calculated for each muscle. Seven muscles displayed good reliability (ICC > 0.80) for all parameters studied. MPF was the most reliable variable, with 12 muscles having ICC > 0.80 and <6% normalized SEM. Reliability and precision differed between muscles of similar function and anatomic region. These data emphasize the need for researchers and clinicians to have reliability and precision measures for all parameters of each muscle, and demonstrates that generalizations must be used cautiously when interpreting EMG data collected during running.  相似文献   

19.
In anesthetized artificially ventilated cats, diaphragmatic fatigue was produced by direct muscle stimulation with trains of pulses for 30 min. Failure of contraction was assessed from decrease in the maximal relaxation rate of transdiaphragmatic pressure twitches. Motor activities (electromyogram and motor phrenic neurogram) were processed by fast-Fourier transform analysis, which provided the power spectrum density function (PSDF). The discharge frequency of diaphragmatic afferents was also measured. In control conditions (before fatigue), intra-arterial bolus injection of lactic acid enhanced tonically active diaphragmatic afferents, whereas it reduced the firing rate of afferent fibers activated in phase with diaphragmatic contraction or relaxation. The same sensory response pattern was observed with the development of diaphragmatic fatigue. Leftward shift in PSDFs of motor phrenic neurogram also occurred, but it preceded the failure of diaphragmatic contraction as well as the changes in the electromyogram's PSDF and afferent paths, which were closely associated with lengthening of both inspiratory and total breath durations. After section of the phrenic nerves, the motor phrenic response disappeared during the fatigue trial. This demonstrates the existence of complex reflex-induced changes in the ventilatory control during diaphragmatic fatigue. They seem to involve the participation of several types of phrenic afferents.  相似文献   

20.
We measured total chest wall impedance (Zw), "pathway impedances" of the rib cage (Zrcpath), and diaphragm-abdomen (Zd-apath), and impedance of the belly wall including abdominal contents (Zbw+) in five subjects during sustained expiratory (change in average pleural pressure [Ppl] from relaxation = 10 and 20 cmH2O) and inspiratory (change in Ppl = -10 and -20 cmH2O) muscle contraction, using forced oscillatory techniques (0.5-4 Hz) we have previously reported for relaxation (J. Appl. Physiol. 66: 350-359, 1989). Chest wall configuration and mean lung volume were kept constant. Zw, Zrcpath, Zd-apath, and Zbw+ all increased greatly at each frequency during expiratory muscle contraction; increases were proportional to effort. Zw, Zrcpath, and Zd-apath increased greatly during inspiratory muscle contraction, but Zbw+ did not. Resistances and elastances calculated from each of the impedances showed the same changes during muscle contraction as the corresponding impedances. Each of the resistances decreased as frequency increased, independent of effort; elastances generally increased with frequency. These frequency dependencies were similar to those measured in relaxed or tetanized isolated muscle during sinusoidal stretching (P.M. Rack, J. Physiol. Lond. 183: 1-14, 1966). We conclude that during respiratory muscle contraction 1) chest wall impedance increases, 2) changes in regional chest wall impedances can be somewhat independent, depending on which muscles contract, and 3) increases in chest wall impedance are due, at least in part, to changes in the passive properties of the muscles themselves.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号