首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A highly sensitive and selective HPLC-MS-MS method was developed for the determination of pramipexole in human plasma. The analytes, pramipexole and BHT-920 (internal standard), were extracted from plasma at basic pH with methyl tert.-butyl ether (MTBE). MTBE was evaporated to dryness and reconstituted in 100 μl of (95:5) methanol-water. Chromatographic separation was achieved on a Zorbax SB-CN column with a mobile phase of (15:5:80) water-0.1 M ammonium acetate—methanol. The analytes were detected utilizing HPLC in conjunction with atmospheric pressure chemical ionization (APCI) tandem mass spectrometry (MSM). The assay was linear in the concentration ranges of 50 to 5000 pg/ml. The analysis of pooled quality controls (150, 750, and 3000 pg/ml) demonstrated excellent precision with relative standard deviations (R.S.D.) (n=18) of 7.2%, 5.3% and 5.2%, respectively. The method is accurate with all intra-day (n=6) and overall (n=18) mean values being less than 11.7% from theoretical.  相似文献   

2.
A simple and fast method intended for large-scale bioequivalence studies for the determination of glibenclamide in plasma samples is presented. The chromatographic separation was achieved on a monolithic octadecyl chemically modified silicagel column and a mobile phase containing 42% aqueous 0.1% HCOOH solution (v/v) and 58% acetonitrile, at a flow rate of 1 mL/min, in isocratic conditions. Preparation of plasma samples was based on protein precipitation with acetonitrile. Gliquidone was used as internal standard. The target analytes were transferred into an ion trap mass analyzer via an atmospheric pressure chemical ionization interface. The precursor ions with mass 494 a.m.u. for glibenclamide and 528 a.m.u. for gliquidone were isolated, while in the second MS stage product ions 369 a.m.u. and 403 a.m.u., respectively, were monitored. The analytical process was characterized by a low limit of quantitation of 1.5 ng/mL. The mean recovery for glibenclamide was 98.1+/-2.8% over a concentration interval ranging from 1 to 500 ng/mL. Intra-day and inter-day precision calculated over 2-400 ng/mL concentration interval ranged from 15.4% to 3.4%. Inter-sequence accuracy expressed as % bias from theoretical concentration values over the concentration interval of 10-400 ng/mL fall within -13.9% and +14.6%. The method was applied for evaluation of the bioequivalence between two formulations containing 3.5mg glibenclamide per dose.  相似文献   

3.
A rapid, sensitive and accurate liquid chromatographic-tandem mass spectrometric method is described for the determination of tamsulosin in dog plasma. Tamsulosin was extracted from plasma using a mixture of hexane-ethyl acetate (2:1, v/v) and separated on a C18 column interfaced with a triple quadrupole tandem mass spectrometer. The mobile phase consisting of a mixture of methanol, water and formic acid (80:20:1, v/v/v) was delivered at a flow rate of 0.5 ml/min. Atmospheric pressure chemical ionization (APCI) source was operated in positive ion mode. Selected reaction monitoring (SRM) mode using the transitions of m/z 409-->m/z 228 and m/z 256-->m/z 166.9 were used to quantify tamsulosin and the internal standard, respectively. The linearity was obtained over the concentration range of 0.1-50.0 ng/ml for tamsulosin and the lower limit of quantitation was 0.1 ng/ml. For each level of QC samples, inter- and intra-run precision was less than 5.0 and 4.0% (relative standard deviation (R.S.D.)), respectively, and accuracy was within +/-0.3% (relative error (R.E.)). This method was successfully applied to pharmacokinetic study of a tamsulosin formulation product after oral administration to beagle dogs.  相似文献   

4.
An HPLC-MS/MS assay for the determination of an HIV integrase inhibitor, 5-(1,1-dioxido-1,2-thiazinan-2-yl)-N-(4-fluorobenzyl)-8-hydroxy-1,6-naphthyridine-7-carboxamide (I) in human plasma has been developed and validated. Compound I and a stable isotope labeled internal standard (II) were isolated from 0.5 mL plasma samples by solid phase extraction using an Ansys SPEC C-8 96-well plate. Extracts were separated on a Hypersil BDS C-18 HPLC column (3.0 mmx50 mm, 3 microm) with a mobile phase consisting of 25 mM ammonium formate pH 3.0:acetonitrile (60:40) vol%/vol% pumped at 0.5 mL/min. A Sciex API 365 mass spectrometer equipped with an atmospheric pressure chemical ionization source was operated in selected reaction monitoring (SRM) mode with the precursor-to-product ion transitions m/z 431-->109 (I) and m/z 437-->115 (II) used for quantitation. The assay was validated over the concentration range of 10-5000 ng/mL and was found to have acceptable accuracy, precision, linearity, and selectivity. The mean extraction recovery from spiked plasma samples was 69%. The intra-day accuracy of the assay was within 4% of nominal and intra-day precision was better than 4% C.V. Following a 200 mg dose of the compound administered to human subjects, concentrations of I ranged from 21.1 to 1500 ng/mL in plasma samples collected up to 12 h after dosing. Inter-day accuracy and precision results for quality control samples run over a 3-month period alongside clinical samples showed mean accuracies of within 6% of nominal and precision better than 3.5% C.V.  相似文献   

5.
Sensitive methods based on capillary gas chromatography (GC) with mass spectrometric (MS) detection in a selected-ion monitoring mode (SIM) for the determination of a cyclooxygenase II (COX-II) inhibitor (3-isopropoxy-4-(4-methanesulfonylphenyl)-5,5'-dimethyl-5H-furan-2-one, I) in human plasma, in two concentration ranges of 0.1-20 and 5-1000 ng/ml, are described. Following liquid-liquid extraction, the residue, after evaporation of the organic phase to dryness, was reconstituted in acetonitrile (20 l) and part of the extract (1 l) was analyzed by GC/MS/SIM. The drug (I) and internal standard (II) were separated on a 25 mx0.2 mm capillary column with HP Ultra 1 (100% dimethylpolysiloxane, 0.33 m) phase and analyzed by MS/SIM monitoring ions at m/z 237 and 282 for I and II, respectively. The standard curve was linear within the lower concentration range of 0.1-20 ng/ml and the lower limit of quantification (LLOQ) in plasma was 0.1 ng/ml. Intraday coefficients of variation (CV, n=5) were 8.9, 4.2, 5.7, 3.1, 1.9, 1.9, and 4.4% at 0.1, 0.2, 0.5, 1.0, 5.0, 10, and 20 ng/ml, respectively. The standard curve was also linear within the higher concentration range of 5-1000 ng/ml and the LLOQ in plasma was 5 ng/ml. Intraday coefficients of variation (CV, n=5) were all below 9% at all concentrations within the standard curve range. The accuracy for I in human plasma was 91-112% and the recovery of I and II was greater than 70% at all concentrations within both standard curve ranges. The details of the assay methodology are presented.  相似文献   

6.
We established a method for precisely determining residual tetracycline antibiotics (TCs) in foods by atmospheric pressure chemical ionization liquid chromatography-tandem mass spectrometry (APCI LC–MS–MS) using selected reaction monitoring with an internal standard. By setting the nebulizer probe temperature to 475°C, we were able to use a mobile phase containing oxalic acid without clogging problems at the APCI interface, since oxalic acid decomposes to carbon dioxide and water at high temperature. DMCTC was very effective as an internal standard for determining TCs in various foods. TCs were cleaned up using a Bond Elut ENV cartridge and analysed by APCI LC–MS–MS. The recovery of TCs from various foods including animal tissues, honey, milk, eggs, and fish fortified at levels of 0.05, 0.10, and 0.50 ppm averaged 60.1–88.9%, with an RSD of 1.2–8.7%. The detection limits were 0.001 ppm for OTC and TC, 0.004 ppm for CTC, and 0.002 ppm for DC. The present method was also successfully used to determine TCs in swine kidney samples that were previously found by microbiological assay.  相似文献   

7.
This work presents the development and the validation of an LC–MS–MS method with atmospheric pressure chemical ionization for the quantitative determination of levamisole, an anthelmintic for veterinary use, in porcine tissue samples. A liquid–liquid back extraction procedure using hexane–isoamylalcohol (95:5, v/v) as extraction solvent was followed by a solid-phase extraction procedure using an SCX column to clean up the tissue samples. Methyllevamisole was used as the internal standard. Chromatographic separation was achieved on a LiChrospher® 60 RP-select B (5 μm) column using a mixture of 0.1 M ammonium acetate in water and acetonitrile as the mobile phase. The mass spectrometer was operated in MS–MS full scanning mode. The method was validated for the analysis of various porcine tissues: muscle, kidney, liver, fat and skin plus fat, according to the requirements defined by the European Community. Calibration graphs were prepared for all tissues and good linearity was achieved over the concentration ranges tested (r>0.99 and goodness of fit <10%). Limits of quantification of 5.0 ng/g were obtained for the analysis of levamisole in muscle, kidney, fat and skin plus fat tissues, and of 50.0 ng/g for liver analysis, which correspond in all cases to half the MRLs (maximum residue limits). Limits of detection ranged between 2 and 4 ng/g tissue. The within-day and between-day precisions (RSD, %) and the results for accuracy fell within the ranges specified. The method has been successfully used for the quantitative determination of levamisole in tissue samples from pigs medicated via drinking water. Moreover the product ion spectra of the levamisole peak in spiked and incurred tissue samples were in close agreement (based on ion ratio measurements) with those of standard solutions, indicating the worthiness of the described method for pure qualitative purposes.  相似文献   

8.
A rapid and reliable analytical method is described for the simultaneous determination of a synthetic progestin norgestimate (NGM), and its metabolites, 17-deacetylnorgestimate (17-DA-NGM), 3-ketonorgestimate (3-keto-NGM) and norgestrel (NGL) in human serum using reversed phase high-performance liquid chromatography (HPLC) with tandem mass spectrometric (MS-MS) detection. The assay was linear over the concentration ranges of 0.1–5.0 ng/ml for 17-DA-NGM and NGL and 0.5–5.0 ng/ml for NGM and 3-keto-NGM. The inter-assay reproducibility was consistently less than 10%. The overall recovery of the analytes ranged from 72 to 92%. Serum profiles following oral administration of norgestimate to female volunteers are presented.  相似文献   

9.
Analytical conditions for underivatized glycosphingolipids by using high-performance liquid chromatography atmospheric pressure ionization mass spectrometry (HPLC/API-MS) were investigated. The analysis was performed by using an ordinary reversed-phase column (4.6 X 150 or 4.6 X 250 mm) at a flow rate of 1 ml/min. The glycosphingolipids could be characterized from the HPLC/API-MS in terms of molecular weight, ceramide composition, and partial oligosaccharide sequence. In order to obtain an adequate spectrum the amount of material needed is in the range of a few micrograms of lipid. By selected ion monitoring the sensitivity of the method allowed characterization of only 60 ng of glycosphingolipid. The method will be very useful in the characterization of small quantities of glycosphingolipids from biological samples.  相似文献   

10.
The presence and identity of very long chain polyunsaturated fatty acids from three freshwater crustacean species, Bathynella natans, B. baicalensis and Baicalobathynella magna from Lake Baikal and caves of central Europe were determined by means of liquid chromatography-mass spectrometry with atmospheric pressure chemical ionization (LC-MS with APCI). LC-MS with APCI enabled the identification of more than 50 very long chain polyunsaturated fatty acids. These acids were described in the crustaceans for the first time, predominantly 26:5n6, 28:7n6, 30:7n3 and 40:7n6. A hypothesis for the biosynthesis of these acids is proposed.  相似文献   

11.
The levels of estrogens and/or their metabolites play important roles in carcinogenesis, reproductive function, and sexual development during perinatal and adolescence periods. The main purpose of this report was to investigate the applicability of high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) with electrospray ionization (ESI) and/or atmospheric pressure chemical ionization (APCI) for simultaneous detection of estrone (E1) and its six metabolites. Both positive and negative ionization modes in ESI and APCI were used to evaluate the signal responses of seven target analytes. Among the seven target analytes, five analytes, E1, 16alpha-hydroxyestrone, 2-methoxyestrone, 4-methoxyestrone, and 2-hydroxyestrone-3-methyl, produced signals with the best signal-to-noise (S/N) ratios in positive APCI-MS/MS mode, while the other two analytes, 2-hydroxyestrone and 4-hydroxyestrone, yielded the best S/N ratios in negative ESI-MS/MS mode. Based on the results of the evaluation, HPLC-APCI-MS/MS with switching between positive and negative modes was recommended for simultaneous detection of E1 and its six metabolites. The proposed analytical scheme was successfully applied in the analysis of cell culture medium of Human liver carcinoma cells treated with varying amounts of 2,3,7,8-tetrachlorodibenzo-p-dioxin.  相似文献   

12.
3-Hydroxy-beta,epsilon-carotene-3'-one (3'-oxolutein) is the major oxidative metabolite of dietary carotenoids in the retina of the human eye. Elucidating the biochemical mechanism of its formation may provide helpful insight into the pathogenesis of age-related macular degeneration; however, it is found in relatively low quantities that require highly sensitive methods for quantitation from individual retinas. Normal-phase high-performance liquid chromatography coupled to atmospheric pressure chemical ionization mass spectrometry allowed us to do quantitative analysis of 3'-oxolutein from central and peripheral retinas obtained from individual human donors. The limit of quantification for 3'-oxolutein in human retina at a signal-to-noise ratio of 10 was 6 pg. The precision of the assay yielded a coefficient of variation ranging from 4.7 to 7.4% and accuracies of 106-108%. A statistically significant (R = 0.99, p < or = 0.001) linear working range was achieved between 5 and 7200 pg. The 3'-oxolutein contents from 8-mm punches of the central macula and peripheral retina were found to be 375+/-192 and 191+/-95 pg/tissue, respectively.  相似文献   

13.
A simple and sensitive HPLC/MS/MS method was developed and evaluated to determine the concentration of ritodrine (RTD) in human plasma. Liquid-liquid extraction with ethyl acetate was employed as the sample preparation method. The structural analogue salbutamol was selected as the internal standard (IS). The liquid chromatography was performed on a Hanbon Sci. & Tech. Lichrospher CN (150 mm x 4.6 mm, i.d., 5 microm) column (Hanbon, China) at 20 degrees C. A mixture of 0.03% acetic acid and methanol (50:50, v/v) was used as isocratic mobile phase to give the retention time 3.60 min for ritodrine and 2.94 min for salbutamol. Selected reaction monitoring (SRM) in positive ionization mode was employed for mass detection. The calibration functions were linear over the concentration range 0.39-100 ng mL(-1). The intra- and inter-day precision of the method were less than 15%. The lower limit of quantification was 0.39 ng mL(-1). The method had been found to be suitable for application to a pharmacokinetic study after oral administration of 20mg ritodrine hydrochloride tablet to 18 healthy female volunteers. The half-life is 2.54+/-0.67 h.  相似文献   

14.
Six arsenic compounds including arsenocholine, arsenobetaine, dimethylarsinic acid, methylarsonic acid, arsenous acid and arsenic acid were separated by high-performance liquid chromatography (HPLC) on a Hamilton PRP-X100 anion-exchange column using isocratic elution and detected by inductively coupled plasma mass spectrometry (ICP-MS). This analytical procedure was applied to the speciation of arsenic compounds in human urine. The influence of urine matrix on the separation of arsenic compounds was evaluated and the determination of arsenic compounds was not hampered by the ArCl interference which has often been encountered in ICP-MS. Three human urine reference materials, SRM 2670 normal level, SRM 2670 elevated level and Lyphocheck urine metal control 1, were analyzed with respect to arsenic compounds by HPLC-ICP-MS. The results were found to be in good agreement with the certified total arsenic concentration in the reference materials. Six arsenic compounds were detected. Arsenobetaine was found to be present in all of the investigated human urine reference materials.  相似文献   

15.
A liquid chromatography–atmospheric pressure chemical ionization tandem mass spectrometry (LC–APCI-MS–MS) method is described for the determination of a thromboxane receptor antagonist (4Z)-6-((2S,4S,5R)-2-(1-(2-cyano-4-methylphenoxy)-1-methylethyl)-4-(3-pyridyl)-3-dioxan-5-yl)hex-4-enoic acid (ZD9583, I) in human plasma and urine. Proteins in plasma and urine samples are precipitated using acidified acetonitrile. The resulting supernatant is chromatographed on a C8 reversed-phase chromatography column. Following the diversion of the solvent front from the mass spectrometer by a switching valve, the column eluate is passed on to the mass spectrometer via a heated nebulizer interface where the analyte is detected by multiple reaction monitoring (MRM). The method has a chromatographic run time of less than 2 min, a linear calibration curve with a range of 1–500 ng ml−1 and intra- and inter-day precision estimates of less than 10% over the calibration range.  相似文献   

16.
A new, selective and sensitive high-performance liquid chromatography (HPLC) method with fluorimetric detection was developed for the determination of tianeptine (TIA) in human plasma using solid phase extraction (SPE) procedures. The method is based on the derivatization of TIA with 4-chloro-7-nitrobenzofurazan (NBD-Cl) in borate buffer of pH 8.5 to yield a yellow, fluorescent product. The HPLC separation was achieved on a Phenomenex C(18) column (250 mm x 4.6 mm) using a mobile phase of acetonitrile-10mM orthophosphoric acid (pH 2.5) (77:23, v/v) solvent system at 1 mL/min flow rate. Gabapentin (GA) was used as the internal standard. The fluorometric detector was operated at 458 nm (excitation) and 520 nm (emission). The assay was linear over the concentration range of 5-300 ng/mL. The detection limit (LOD) was found to be 2 ng/mL. The mean recovery was determined to be 88.6%. The proposed method was applied for pharmacokinetic study of 12.5mg TIA in a healthy volunteer.  相似文献   

17.
A highly sensitive and enantioselective assay has been developed and validated for the estimation of torcetrapib (TTB) enantiomers [(+)-TTB and (-)-TTB] in hamster plasma with chiral liquid chromatography coupled to tandem mass spectrometry with an atmospheric pressure chemical ionization interface in the negative-ion mode. The assay procedure involves liquid-liquid extraction of TTB enantiomers and IS (DRL-16126) from 100 microL hamster plasma with acetonitrile. TTB enantiomers were separated using n-hexane:propanol (80:20, v/v) at a flow rate of 0.7 mL/min on a Chiralpak AD column. The MS/MS ion transitions monitored were 599.2-->340.2 for TTB and 623.2-->298.1 for IS. Absolute recovery was found to be between 64 and 68% for TTB enantiomers and >100% for IS. The standard curves for TTB enantiomers were linear (r(2)>0.995) in the concentration range 5-2500 ng/mL for each enantiomer with an LLOQ of 5 ng/mL for each enantiomer. The inter- and intra-day precisions were in the range of 10.5-12.4 and 9.15-11.5% and 3.75-12.9 and 5.16-12.5% for (+)-TTB and (-)-TTB, respectively. Accuracy in the measurement of quality control (QC) samples was in the range 91.3-105 and 88.6-111% for (+)-TTB and (-)-TTB, respectively. This novel method has been applied to the study of stereoselective oral pharmacokinetics of (-)-TTB.  相似文献   

18.
A sensitive, specific, accurate and reproducible LC-MS-MS method was developed and validated for the simultaneous determination of rivastigmine and its major metabolite NAP 226-90 in human plasma according to International Regulatory Requirements. After addition of their respective labelled internal standards, the compounds were extracted from plasma using methyl-tert.-butyl ether at basic pH with a simultaneous derivatization of NAP 226-90 with propionic anhydride, and backextracted into an acidic solution. After re-extraction the compounds were analyzed on a 3-micrometer Purospher Star RP-18 column interfaced with a MDS Sciex API 3000 triple quadrupole mass spectrometer. Positive atmospheric chemical ionization was employed as the ionization source. The analytes and their internal standards were detected by use of multiple reaction monitoring mode. Intra- and inter-day accuracy and precision were found suitable over the range of concentrations between 0.200 and 30.0 ng/ml. The LC-MS-MS method was crossvalidated with a previously developed in-house GC-MS method by the analysis of plasma samples obtained from patients after administration of Exelon((R)) capsules and showed excellent correlation between the methods.  相似文献   

19.
By use of negative ion chemical ionization and collision-activated decomposition in a triple quadrupole mass spectrometer a method has been developed for the quantification of ergotamine in human plasma at levels down to 2 pg ml-1.  相似文献   

20.
A high-performance liquid chromatographic method is described for the determination of opipramol in human plasma. Opipramol was extracted into tert.-butylmethyl ether, separated on a cyanopropyl silica column and detected at 254 nm. Imipramine was used as internal standard. The limit of quantitation was 250 pg/ml using 1.5 ml plasma. Precision was better than 9%, inaccuracy less than 8%. The assay is more sensitive than previously published methods, and it has been applied to the analysis of plasma samples from a pharmacokinetic study.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号