首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
An amperometric biosensor has been developed for monitoring glutamine in the pulsed-batch cultivation of murine hybridoma cells. Glutamine oxidase was cross-linked with bovine serum albumin (BSA) via glutaraldehyde activation and deposited on a preactivated nylon membrane. Glutaminase was then immobilized on the protein layer and the resulting membrane was attached to the sensing area of a hydrogen peroxide probe (platinum vs silver/silver chloride polarized at +0.7 V). An orthogonal test was performed to optimize the activity of the membrane for glutamine with respect to the concentrations of glutamate oxidase, BSA, glutaminase and glutaraldehyde. There was an excellent linear relationship between the biosensor's response and glutamine in the range 0.1-3 mM. The determination of glutamine could be performed in 2 min and each membrane was reused for at least 300 consecutive analyses. The data obtained also agreed well with those high-performance liquid chromatography, thus validating the applicability of the biosensor.  相似文献   

2.
Together with flow injection analysis (FIA), a chemiluminescence (CL) fiber optic biosensor system has been developed for determining glutamine in animal cell cultures. Glutaminase (GAH) and glutamate oxidase (GLO) were onto separate porous aminopropyl glass beads via glutaraldehyde activation and packed to form an enzyme column. These two enzymes acted in sequence on glutamine to produce hydrogen peroxide, which was then reacted with luminol in the presence of ferricyanide to produce a light signal. An anion exchanger was introduced on-line to eliminate interfering endogenous glutamate in view of its negative charge at pH above 3.22 (isoelectric pH). Among several resins tested, the acetate form was most effective, and this type of ion exchanger also effectively adsorbed uric acid, acetaminophen, and aspartic acid.There was an excellent linear relationship between the CL response and standard glutamine concentration in the range 1 to 100 muM. A complete analysis could be performed in 2 min, including sampling and washing with a good reproducibility (+/- 4.4%). Both the bi-enzymic and ion exchange columns were useful for at least 500 analyses when the biosensor system was applied for the glutamine determination in murine hybridoma cell cultures and insect cell cultures. The values obtained compared well with those of HPLC, thus validating the applicability of the CL fiber optic system. (c) 1993 John Wiley & Sons, Inc.  相似文献   

3.
4.
A novel flow-injection chemiluminescence (CL) method for the determination of guanine was developed. The procedure is based on the CL reaction of guanine with hydrogen peroxide in borax buffer (pH 8.5) with Co2+ as a catalyst. The calibration graph is linear within the range of 3 x 10(-7)-9 x 10(-5) g/mL. A detection limit of 1 x 10(-7) g/mL, along with a relative standard deviation of 2.23% (3 x 10(-7) g/mL guanine, n = 11), were obtained. The present procedure was applied to the measurement of guanine in urine with recoveries of 97.5-107.5%. A possible CL mechanism of the reaction system is proposed.  相似文献   

5.
Nitric oxide (NO) is the smallest known gaseous signaling molecule released by mammalian and plant cells. To investigate the pathophysiologic role of exogenous NO gas (gNO) in bacterial and mammalian cell cultures, a validated in vitro delivery method is required. The system should be able to deliver gNO directly to bacterial and/or cell cultures in a continuous, predictable, and reproducible manner over a long period of time (days). To accomplish this, a gas delivery system was designed to provide optimal growth conditions for bacteria and/or mammalian cells. Parameters for cell exposure, such as concentration of gNO, nitrogen dioxide (NO(2)), oxygen (O(2)), temperature, and relative humidity (RH) were continuously monitored and evaluated. Uptake of gNO into various media was monitored by measuring the nitrite concentration using the Griess reagent technique. A selection of standard growth media [saline, tryptic soy broth (TSB), Middlebrook 7H9 (MB 7H9), and Dulbecco's modified Eagle's medium (DMEM)] exposed to various concentrations of gNO revealed a steady and consistent transfer of gNO into the aqueous phase over a 48-h period. Validation of optimal growth conditions within the device, as compared to a conventional incubator, were accomplished by growing and observing viability of Escherichia coli, Pseudomonas aeruginosa, Staphylococcus aureus, and human fibroblast cultures in the absence of gNO. These results indicate that an optimal growth environment for the above tested cells was accomplished inside the proposed delivery system. Dose-dependent toxicological data revealed a significant bacteriostatic effect on P. aeruginosa and S. aureus with continuous exposure to 80 ppm gNO. No toxic effects were observed on dermal fibroblast proliferation at concentrations up to 400 ppm gNO for 48 h. In conclusion, the designed gNO exposure system is capable of supporting cellular viability for a representative range of prokaryote and eukaryotic cells. The exposure system is also capable of obtaining toxicological data. Therefore, the proposed device can be utilized to continuously expose cells to various levels of gNO for up to 72 h to study the in vitro effects of gNO therapy.  相似文献   

6.
Many high‐value added recombinant proteins, such as therapeutic glycoproteins, are produced using mammalian cell cultures. In order to optimize the productivity of these cultures it is important to monitor cellular metabolism, for example the utilization of nutrients and the accumulation of metabolic waste products. One metabolic waste product of interest is lactic acid (lactate), overaccumulation of which can decrease cellular growth and protein production. Current methods for the detection of lactate are limited in terms of cost, sensitivity, and robustness. Therefore, we developed a whole‐cell Escherichia coli lactate biosensor based on the lldPRD operon and successfully used it to monitor lactate concentration in mammalian cell cultures. Using real samples and analytical validation we demonstrate that our biosensor can be used for absolute quantification of metabolites in complex samples with high accuracy, sensitivity, and robustness. Importantly, our whole‐cell biosensor was able to detect lactate at concentrations more than two orders of magnitude lower than the industry standard method, making it useful for monitoring lactate concentrations in early phase culture. Given the importance of lactate in a variety of both industrial and clinical contexts we anticipate that our whole‐cell biosensor can be used to address a range of interesting biological questions. It also serves as a blueprint for how to capitalize on the wealth of genetic operons for metabolite sensing available in nature for the development of other whole‐cell biosensors. Biotechnol. Bioeng. 2017;114: 1290–1300. © 2017 The Authors. Biotechnology and Bioengineering Published by Wiley Periodicals, Inc.  相似文献   

7.
An intercalating fluorochrome, PicoGreen, was assessed for its ability to determine the concentration of DNA in clarified mammalian cell culture broths containing monoclonal antibodies. Fluorescent signal suppression was ameliorated by sample dilution or by performing the assay above the pI of secreted IgG. The source of fluorescence in clarified culture broth was validated by incubation with RNase A and DNase I. At least 91.8% of fluorescence was attributable to nucleic acid and pre-digestion with RNase A was shown to be a requirement for successful quantification of DNA in such samples.  相似文献   

8.
A flow injection analysis (FIA) biosensor system for the determination of phosphate was constructed using immobilized nucleoside phosphorylase and xanthine oxidase and an amperometric electrode (platinum vs silver/silver chloride, polarized at 0.7 V). When a phosphate-containing sample was injected into the detection cell, phosphate reacted with inosine in the carrier buffer to produce hypoxanthine and ribose-1-phosphate in the presence of nucleoside phosphorylase. Hypoxanthine was then oxidized by xanthine oxidase to uric acid and hydrogen peroxide, which were both detected by the amperometric electrode. The response of the FIA biosensor system was linear up to 100 microM phosphate, with a minimum detectable concentration of 1.25 microM phosphate. Each assay could be performed in 5-6 min and the system could be used for about 160 repeated analyses. This system was applicable for the determination of phosphate in various food products and plasma, and the results obtained agreed well with those of the enzymatic assay.  相似文献   

9.
Yu J  Wang S  Ge L  Ge S 《Biosensors & bioelectronics》2011,26(7):3284-3289
In this work, chemiluminescence (CL) method was combined with microfluidic paper-based analytical device (μPAD) to establish a novel CL μPAD biosensor for the first time. This novel CL μPAD biosensor was based on enzyme reaction which produced H(2)O(2) while decomposing the substrate and the CL reaction between rhodanine derivative and generated H(2)O(2) in acid medium. Microchannels in μPAD were fabricated by cutting method. And the possible CL assay principle of this CL μPAD biosensor was explained. Rhodanine derivative system was used to reach the purpose of high sensitivity and well-defined signal for this CL μPAD biosensor. And the optimum reaction conditions were investigated. The quantitative determination of uric acid could be achieved by this CL μPAD biosensor with accurate and satisfactory result. And this biosensor could provide good reproducible results upon storage at 4°C for at least 10 weeks. The successful integration of μPAD and CL reaction made the final biosensor inexpensive, easy-to-use, low-volume, and portable for uric acid determination, which also greatly reduces the cost and increases the efficiency required for an analysis. We believe this simple, practical CL μPAD biosensor will be of interest for use in areas such as disease diagnosis.  相似文献   

10.
1. The concentration of HCO3- (independent of any change of pH) exerts different effects on glutamine metabolism in rat kidney-cortex tubules, hepatocytes and enterocytes.2. In kidney tubules HCO3- (10.5-50 MM) has no effect on glutaminase (EC 3.5.1.2), whereas glutamate dehydrogenase (EC 1.4.1.3) is inhibited as HCO3- concentration is increased. The result is that flux through the entire glutamate-to-glucose pathway is inhibited by increasing HCO3- concentrations. A large proportion (more than 30%) of the glutamine removed undergoes complete oxidation. 3. In hepatocytes, and to a smaller extent in enterocytes, HCO3- is an accelerator of glutaminase. Synthesis of glucose and urea from glutamine in hepatocytes increases as HCO3- concentration is increased. Calculations show that fumarate, formed via aspartate aminotransferase and arginino-succinate lyase, is the precursor of the glucose. There is no complete oxidation of the carbon skeleton of glutamine in hepatocytes. 4. Leucine at near-physiological concentrations (0.1-1 mM) is an accelerator of glutaminase in hepatocytes, but not in kidney tubules or in enterocytes. 5. The results are discussed in relation to regulation of acid/base balance in vivo.  相似文献   

11.
A biowaste kill system was implemented to treat biological waste generated from a clinical manufacturing and R&D antibody facility. To confirm that design parameters of this continuous decontamination system are sufficient to inactivate mammalian cell culture waste, bench-scale experiments were conducted. The biowaste kill system heat inactivates mammalian cell cultures before they are piped to a neutralization tank and subsequently released to the sewage system. Heat inactivation of cells is accomplished by exposing cells to 80 degrees C for 1 min. Small-scale heat inactivation studies were performed on CHO, 293-HEK, and hybridoma cells. Cells at 1 x 10(6) cells/mL or 1 x 10(7) cells/mL were exposed to 37, 60, 70, or 80 degrees C for 0, 30, 60, and 120 s. Viability based on trypan blue exclusion method and ability to proliferate was assessed after exposure to heat. Data suggest that exposure of cells to 80 degrees C for 60 s is sufficient to inactivate these cultures before they are released to the sewage system.  相似文献   

12.
We present the setup of a flow injection analysis system designed for on-line monitoring of glutamate and glutamine. These amino acids represent a major energy source in mammalian cell culture. A cycling assay consisting of glutamate dehydrogenase and aspartate aminotransferase produces NADH proportional to the glutamate concentration in the sample. NADH is then measured spectrophotometrically. Glutamine is determined by conversion to glutamate which is fed into the cycling assay. The conversion of glutamine to glutamate is catalyzed by asparaginase. Asparaginase was used in place of glutaminase due to its relatively high reactivity with glutamine and a pH optimum similar to that of glutamate dehydrogenase. The enzymes were immobilized covalently to activated controlled pore glass beads and integrated into the flow injection analysis system. The application of the immobilized enzymes and the technical setup are presented in this paper.  相似文献   

13.
Summary The design and use of a unit for planting uniform inocula for replicate cultures are described. Its design permits continuous gassing of suspensions of mammalian cells with humidified CO2, thus stabilizing the pH (±<0.05 pH unit) of culture media buffered with sodium bicarbonate. The unit can be readily modified to deliver different volumes; identical samples can be dispensed simply and rapidly, with minimal cell damage and chance of microbial contamination. Quantitative data regarding sample uniformity and growth subsequent to planting with this unit are presented.  相似文献   

14.
15.
Summary The design and use of a unit for planting uniform inocula for replicate cultures are described. Its design permits continuous gassing of suspensions of mammalian cells with humidified CO2, thus stabilizing the pH (±<0.05 pH unit) of culture media buffered with sodium bicarbonate. The unit can be readily modified to deliver different volumes; identical samples can be dispensed simply and rapidly, with minimal cell damage and chance of microbial contamination. Quantitative data regarding sample uniformity and growth subsequent to planting with this unit are presented.  相似文献   

16.
17.
18.
A large number of assays are available to monitor viability in mammalian cell cultures with most defining loss of viability as a loss of plasma membrane integrity, a characteristic of necrotic cell death. However, the majority of cultured cells die by apoptosis and early apoptotic cells, although non-viable, maintain an intact plasma membrane and are thus ignored. Here we measure the viability of cultures of a number of common mammalian cell lines by assays that measure membrane integrity (a measure of necrotic cell death) and assays that measure apoptotic cells, and show that discrepancies in the measurement of culture viability have a significant impact on the calculation of cell culture parameters and lead to skewed experimental data.  相似文献   

19.
Cell culture technology has become a widely accepted method used to derive therapeutic and diagnostic protein products. Mammalian cells adapted to grow in bioreactors now play an integral role in the development of these biologicals. A major limiting factor determining the output efficiency of mammalian cell cultures however, is apoptosis or programmed cell death. Methods to delay apoptosis and increase the longevity of cell cultures can lead to more economical processes. Researchers have shown that both genetic and chemical strategies to block apoptotic signals can increase cell culture productivity. Here, we discuss various strategies which have been implemented to improve cellular viabilities and productivities in batch cultures.  相似文献   

20.
A new biosensing flow injection method for the determination of alpha-amylase activity has been introduced. The method is based on the analysis of maltose produced during the hydrolysis of starch in the presence of alpha-amylase. Maltose determination in the flow system was allowed by the application of peroxide electrode equipped with an enzyme membrane. The membrane was obtained by immobilisation of glucose oxidase, alpha-glucosidase and optionally mutarotase on a cellophane, co-crosslinked by gelatin-glutaraldehyde together with bovine serum albumine. alpha-Glucosidase hydrolyses maltose to alpha-D-glucose, which is converted to beta-D-glucose by mutarotase. beta-D-Glucose is then determined via glucose oxidase. The new biosensor has the limit of detection of 50 nmol l(-1) maltose, which means 2 nkat ml(-1) in alpha-amylase activity units, when the reaction time of amylase was 5 min (determined with respect to a signal-to-noise ratio 3:1). When the reaction time of alpha-amylase was 30 min, the limit of detection was 0.5 nkat ml(-1). A linear range of current response was 0.1-3 mmol l(-1) maltose, with a response time of 35s. The biosensor was stable at least two months and retained 70% of its original activity (with mutarotase the stability is decreased to 3 weeks). When the enzyme membrane was stored in a dry state at 4 degrees C in a refrigerator, the lifetime was approximately 6 months (with mutarotase only 3 months).  相似文献   