首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
The aims of this study were to examine the effect of implant neck design and cortical bone thickness using 3D finite element analysis and to analyse the stability of clinical evidence based on micromotion and principal stress. Four commercial dental implants for a type IV bone and maxillary segments were created. Various parameters were considered, including the osseointegration condition, loading direction and cortical bone thickness. Micromotion and principal stresses were used to evaluate the failure of osseointegration and bone overloading, respectively. It was found that the maximum stress of the peri-implant bone decreased as cortical bone thickness increased. The micromotion level in full osseointegration is less than that in non-osseointegration and it also decreases as cortical bone thickness increases. The cortical bone thickness should be measured before surgery to help select a proper implant. In the early stage of implantation, the horizontal loading component induces stress concentration in bone around the implant neck more easily than does the vertical loading component, and this may result in crestal bone loss.  相似文献   

2.
Factors related to micromovements at bone-implant interface have been studied because they are considered adverse to osseointegration. Simplifications are commonly observed in these FEA evaluations. The aim of this study was to clarify the influence of FEA parameters (boundary conditions and bone properties) on the stress distribution in peri-implant bone tissue when micromovements are simulated in implants with different geometries. Three-dimensional models of an anterior section of the jaw with cylindrical or conical titanium implants (4.1 mm in width and 11 mm in length) were created. Micromovement (50, 150, or 250 μm) was applied to the implant. The FEA parameters studied were linear vs. non-linear analyses, isotropic vs. orthogonal anisotropic bone, friction coefficient (0.3) vs. frictionless bone-implant contact. Data from von Mises, shear, maximum, and minimum principal stresses in the peri-implant bone tissue were compared. Linear analyses presented a relevant increase of the stress values, regardless of the bone properties. Frictionless contact reduced the stress values in non-linear analysis. Isotropic bone presented lower stress than orthogonal anisotropic. Conical implants behave better, in regard to compressive stresses (minimum principal), than cylindrical ones, except for nonlinear analyses when micromovement of 150 and 250 μm were simulated. The stress values raised as the micromovement amplitude increased. Non-linear analysis, presence of frictional contact and orthogonal anisotropic bone, evaluated through maximum and minimum principal stress should be used as FEA parameters for implant-micromovement studies.  相似文献   

3.
Abstract

Objectives: The purpose of the present study was to evaluate the distribution and magnitude of stresses through the bone tissue surrounding Morse taper dental implants at different positioning relative to the bone crest. Materials and Methods: A mandibular bone model was obtained from a computed tomography scan. A three-dimensional (3D) model of Morse taper implant-abutment systems placed at the bone crest (equicrestal) and 2?mm bellow the bone crest (subcrestal) were assessed by finite element analysis (FEA). FEA was carried out on axial and oblique (45°) loading at 150 N relatively to the central axis of the implant. The von Mises stresses were analysed considering magnitude and volume of affected peri-implant bone. Results: On vertical loading, maximum von Mises stresses were recorded at 6-7?MPa for trabecular bone while values ranging from 73 up to 118?MPa were recorded for cortical bone. On oblique loading at the equiquestral or subcrestal positioning, the maximum von Mises stresses ranged from 15 to 21?MPa for trabecular bone while values at 150?MPa were recorded for the cortical bone. On vertical loading, >99.9vol.% cortical bone volume was subjected to a maximum of 2?MPa while von Mises stress values at 15?MPa were recorded for trabecular bone. On oblique loading, >99.9vol.% trabecular bone volume was subjected to maximum stress values at 5?MPa, while von Mises stress values at 35?MPa were recorded for >99.4vol.% cortical bone. Conclusions: Bone volume-based stress analysis revealed that most of the bone volume (>99% by vol) was subjected to significantly lower stress values around Morse taper implants placed at equicrestal or subcrestal positioning. Such analysis is commentary to the ordinary biomechanical assessment of dental implants concerning the stress distribution through peri-implant sites.  相似文献   

4.
Osseointegration of implant provides a stable support for the prosthesis under functional loads. The timing of loading is a critical parameter that can govern the success of the osseointegration of implant. However, it is not clear whether the early loading can affect the success of osseointegration, or whether the no-loading healing period can be shortened. This paper presents an animal study conducted to investigate how external loads influence the osseointegration at the initial stage of healing. Titanium implants were inserted into the goat tibia laterally, and different axial loadings were applied to the implants in 4 weeks after surgery. After the 2 weeks period of early loading, animals were sacrificed and the tibia bones with the implants were cut off from the bodies. Then mechanical test was employed to find out the differences in the pull-out force, and shear strength at the bone-implant interface between the non-loaded and the loaded implants. The implant-bone interfaces were analyzed by histomorphometric method, SEM (scanning electron micrograph) and EDS (energy density spectrum). The results indicated that the bone-implant interface did not well integrate 4 weeks after surgery, and the fibrous tissue could be found at the interfaces of the specimens without loadings. While the results of loaded specimens with 10 N axial force showed that that parts of the interface were well integrated, indicating that the early mild loading may play a positive role in the process of the osseointegration. The results support that a certain range of external loading would influence the process of osseointegration, and appropriate mechanical loading can be applied to shorten the osseointegration period after surgery. Supported by the National Natural Science Foundation of China (Grant Nos. 30370376, 10529202 and 10672015).  相似文献   

5.
Extreme stresses in surrounding bone are among the most important reasons for implant failure. Bone density (quality) is a variable that plays a decisive role in achieving predictable osseointegration and long-term survival of implants. The magnitudes of ultimate occlusal load, which generate ultimate von Mises stress at the critical point of peri-implant area for the spectrum of implants inserted into mandible with four different bone qualities (Lekholm and Zarb classification), were calculated. Geometric models of mandible segment were generated from computed tomography images and analysed with osseointegrated cylindrical implants of various dimensions. Occlusal loads were applied in their natural direction. All materials were assumed to be linearly elastic and isotropic. The investigation suggests that an implant's ultimate occlusal load indicates its load-carrying capacity. As a result, bone loss can be predicted, and viable implants can be selected by comparing the values of their ultimate occlusal load in different clinical conditions.  相似文献   

6.
The determining factors for the fixation of uncemented screws in bone are the bone-implant interface and the peri-implant bone. The goal of this work was to explore the role of the peri-implant bone architecture on the mechanics of the bone-implant system. In particular, the specific aims of the study were to investigate: (i) the impact of the different architectural parameters, (ii) the effects of disorder, and (iii) the deformations in the peri-implant region. A three-dimensional beam lattice model to describe trabecular bone was developed. Various microstructural features of the lattice were varied in a systematic way. Implant pull-out tests were simulated, and the stiffness and strength of the bone-implant system were computed. The results indicated that the strongest decrease in pull-out strength was obtained by trabecular thinning, whereas pull-out stiffness was mostly affected by trabecular removal. These findings could be explained by investigating the peri-implant deformation field. For small implant displacements, a large amount of trabeculae in the peri-implant region were involved in the load transfer from implant to bone. Therefore, trabecular removal in this region had a strong negative effect on pull-out stiffness. Conversely, at higher displacements, deformations mainly localized in the trabeculae in contact with the implant; hence, thinning those trabeculae produced the strongest decrease in the strength of the system. Although idealized, the current approach is helpful for a mechanical understanding of the role played by peri-implant bone.  相似文献   

7.
Dental implantology has high success rates, and a suitable estimation of how stresses are transferred to the surrounding bone sheds insight into the correct design of implant features. In this study, we estimate stress transfer properties of four commercial implants (GMI, Lifecore, Intri and Avinent) that differ significantly in macroscopic geometry. Detailed three-dimensional finite element models were adopted to analyse the behaviour of the bone-implant system depending on the geometry of the implant (two different diameters) and the bone-implant interface condition. Occlusal static forces were applied and their effects on the bone, implant and bone-implant interface were evaluated. Large diameters avoided overload-induced bone resorption. Higher stresses were obtained with a debonded bone-implant interface. Relative micromotions at the bone-implant interface were within the limits required to achieve a good osseointegration. We anticipate that the methodology proposed may be a useful tool for a quantitative and qualitative comparison between different commercial dental implants.  相似文献   

8.
The aim of this study is to predict the evolution of the resonance frequency of the bone-implant interface in a dental implant by means of finite element simulation. A phenomenological interface model able to simulate the mechanical effects of the osseointegration process at the bone-implant interface is applied and compared with some experimental results in rabbits. An early stage of slow bone ingrowth, followed by a faster osseointegration phase until final stability is predicted by the simulations. The evolution of the resonance frequency of the implant and surrounding tissues along the simulation period was also obtained, observing a 3-fold increase in the first principal frequency. These findings are in quantitative agreement with the experimental measurements and suggest that the model can be useful to evaluate the influence of mechanical factors such as implant geometry or implant loading on the indirect evaluation of the process of implant osseintegration.  相似文献   

9.
There is an ongoing requirement for a clinically relevant, noninvasive technique to monitor the integrity of percutaneous implants used for dental restorations, bone-anchored hearing aids, and to retain extra-oral prostheses (ear, eye, nose, etc). Because of the limitations of conventional diagnostic techniques (CT, MRI), mechanical techniques that measure the dynamic response of the implant-abutment system are being developed. This paper documents a finite element analysis that simulates a transient response to mechanical impact testing using contact elements. The detailed model allows for a specific interface between the implant and bone and characterizes potential clinical situations including loss of bone margin height, loss of osseointegration, and development of a soft connective tissue layer at the bone-implant interface. The results also show that the expected difference in interface stiffness between soft connective tissue and osseointegrated bone will cause easily measurable changes in the response of the implant/abutment system. With respect to the loss of bone margin height, changes in the order of 0.2 mm should be detectable, suggesting that this technique is at least as sensitive as radiography. A partial loss of osseointegration, while not being as readily evident as a bone margin loss, would still be detectable for losses as small as 0.5 mm.  相似文献   

10.
Although research has been addressed at investigating the effect of specific loading regimes on bone response around the implant, a precise quantitative understanding of the local mechanical response close to the implant site is still lacking. This study was aimed at validating micro-CT-based finite element (μFE) models to assess tissue strains after implant placement in a rat tibia. Small implants were inserted at the medio-proximal site of 8 rat tibiae. The limbs were subjected to axial compression loading; strain close to the implant was measured by means of strain gauges. Specimen-specific μFE models were created and analyzed. For each specimen, 4 different models were created corresponding to different representations of the bone–implant interface: bone and implant were assumed fully osseointegrated (A); a low stiffness interface zone was assumed with thickness of 40 μm (B), 80 μm (C), and 160 μm (D). In all cases, measured and computational strains correlated highly (R 2 = 0.95, 0.92, 0.93, and 0.95 in A, B, C, and D, respectively). The averaged calculated strains were 1.69, 1.34, and 1.15 times higher than the measured strains for A, B, and C, respectively, and lower than the experimental strains for D (factor = 0.91). In conclusion, we demonstrated that specimen-specific FE analyses provide accurate estimates of peri-implant bone strains in the rat tibia loading model. Further investigations of the bone-implant interface are needed to quantify implant osseointegration.  相似文献   

11.
Small endosseous implants, such as screws, are important components of modern orthopedics and dentistry. Hence they have to reliably fulfill a variety of requirements, which makes the development of such implants challenging. Finite element analysis is a widely used computational tool used to analyze and optimize implant stability in bone. For these purposes, bone is generally modeled as a continuum material. However, bone failure and bone adaptation processes are occurring at the discrete level of individual trabeculae; hence the assessment of stresses and strains at this level is relevant. Therefore, the aim of the present study was to investigate how peri-implant strain distribution and load transfer between implant and bone are affected by the continuum assumption. We performed a computational study in which cancellous screws were inserted in continuum and discrete models of trabecular bone; axial loading was simulated. We found strong differences in bone-implant stiffness between the discrete and continuum bone model. They depended on bone density and applied boundary conditions. Furthermore, load transfer from the screw to the surrounding bone differed strongly between the continuum and discrete models, especially for low-density bone. Based on our findings we conclude that continuum bone models are of limited use for finite element analysis of peri-implant mechanical loading in trabecular bone when a precise quantification of peri-implant stresses and strains is required. Therefore, for the assessment and improvement of trabecular bone implants, finite element models which accurately represent trabecular microarchitecture should be used.  相似文献   

12.
Development of surface treatments has enabled secure attachment of dental implants in less than 1 month. Consequently, it is necessary to characterize accurately the osseointegration of the implant surface in the region of the bone-implant contact (BIC). We developed a method for sample preparation that preserves both bone and BIC to permit analysis of the contact interface. We prepared eight nanotextured implants and implanted them in rabbit tibias. After healing for 30 days, outcomes were analyzed using both our bone preservation protocol and routine decalcification followed by preparation of histological sections stained by hematoxylin and eosin (H & E). Pull-out tests for implant osseointegration were performed after healing. Non-implanted samples of rabbit mandible were used as a control for assessing organic and mineralized bone characteristics and bone structure. Our bone preservation protocol enabled evaluation of many of the same bone characteristics as histological sections stained with H & E. Our protocol enables analysis of implant samples, implant surfaces and osseointegration without risk of BIC damage.  相似文献   

13.
Dental implant failure is mainly the consequence of bone loss at peri-implant area. It usually begins in crestal bone. Due to this gradual loss, implants cannot withstand functional force without bone overload, which promotes complementary loss. As a result, implant lifetime is significantly decreased. To estimate implant success prognosis, taking into account 0.2 mm annual bone loss for successful implantation, ultimate occlusal forces for the range of commercial cylindrical implants were determined and changes of the force value for each implant due to gradual bone loss were studied. For this purpose, finite element method was applied and von Mises stresses in implant–bone interface under 118.2 N functional occlusal load were calculated. Geometrical models of mandible segment, which corresponded to Type II bone (Lekholm & Zarb classification), were generated from computed tomography images. The models were analyzed both for completely and partially osseointegrated implants (bone loss simulation). The ultimate value of occlusal load, which generated 100 MPa von Mises stresses in the critical point of adjacent bone, was calculated for each implant. To estimate longevity of implants, ultimate occlusal loads were correlated with an experimentally measured 275 N occlusal load (Mericske-Stern & Zarb). These findings generally provide prediction of dental implants success.  相似文献   

14.
Osseointegration of bone marrow-PLGA-coated, preformed polymethylmethacrylate cranioplasties offers the possibility of reducing: operative time, periimplant seroma and infection, metallic fixation, and periprosthetic resorption following surgical skull remodeling. These alloplastic materials are FDA-approved but previously have not been used together to promote cranioplasty incorporation. The objective of this study was to determine whether the use of PLGA foam coating improves host osseointegration of preformed, textured, polymethylmethacrylate prosthetic cranioplasties. A critical-sized cranial defect was created in two groups of 10 and one group of three rabbits. The defect was filled with either a textured, preformed polymethylmethacrylate disc or a textured, preformed polymethylmethacrylate disc coated with poly (DL-lactic-co-glycolic acid). Both implants were immersed in autologous bone marrow for 20 minutes before implantation. Half of each group of 10 were killed at 3 weeks, and the remainder at 6 weeks. A third group of three rabbits with excised periosteum was evaluated at 6 weeks. Histologic analysis of the discs determined relative amounts of cancellous bone formation adjacent to the prostheses. Woven trabecular bone was present at each host bone to implant perimeter interface at 3 weeks, with fine fibrous capsular formation around the implants. Thicker, lamellar trabeculae were present at 6 weeks with an increased fibrous layer surrounding both types of implants. Bone formed on the superficial and deep implant surfaces in a noncontiguous fashion. Two of five measures showed that total bone formation was significantly greater in the PLGA-coated implants. Polymethylmethacrylate discs coated with bone marrow-impregnated PLGA foam demonstrate increased bone formation at 3 and 6 weeks as compared with non-coated preformed polymethylmethacrylate discs. Only implants with preserved periosteum showed bone formation away from the host-implant interface (centrally) on the superficial surface at 6 weeks.  相似文献   

15.
The study focused on the influence of the implant material stiffness on stress distribution and micromotion at the interface of bone defect implants. We hypothesized that a low-stiffness implant with a modulus closer to that of the surrounding trabecular bone would yield a more homogeneous stress distribution and less micromotion at the interface with the bony bed. To prove this hypothesis we generated a three-dimensional, non-linear, anisotropic finite element (FE) model. The FE model corresponded to a previously developed animal model in sheep. A prismatic implant filled a standardized defect in the load-bearing area of the trabecular bone beneath the tibial plateau. The interface was described by face-to-face contact elements, which allow press fits, friction, sliding, and gapping. We assumed a physiological load condition and calculated contact pressures, shear stresses, and shear movements at the interface for two implants of different stiffness (titanium: E=110GPa; composite: E=2.2GPa). The FE model showed that the stress distribution was more homogeneous for the low-stiffness implant. The maximum pressure for the composite implant (2.1 MPa) was lower than for the titanium implant (5.6 MPa). Contrary to our hypothesis, we found more micromotion for the composite (up to 6 microm) than for the titanium implant (up to 4.5 microm). However, for both implants peak stresses and micromotion were in a range that predicts adequate conditions for the osseointegration. This was confirmed by the histological results from the animal studies.  相似文献   

16.
The objective of this study was to predict time-dependent bone remodeling around tissue- and bone-level dental implants used in patients with reduced bone width. The remodeling of bone around titanium tissue-level, and titanium and titanium–zirconium alloy bone-level implants was studied under 100 N oblique load for one month by implementing the Stanford theory into three-dimensional finite element models. Maximum principal stress, minimum principal stress, and strain energy density in peri-implant bone and displacement in x- and y- axes of the implant were evaluated. Maximum and minimum principal stresses around tissue-level implant were higher than bone-level implants and both bone-level implants experienced comparable stresses. Total strain energy density in bone around titanium implants slightly decreased during the first two weeks of loading followed by a recovery, and the titanium–zirconium implant showed minor changes in the axial plane. Total strain energy density changes in the loading and contralateral sides were higher in tissue-level implant than other implants in the cortical bone at the horizontal plane. The displacement values of the implants were almost constant over time. Tissue-level implants were associated with higher stresses than bone-level implants. The time-dependent biomechanical outcome of titanium–zirconium alloy bone-level implant was comparable to the titanium implant.  相似文献   

17.
Peri-implantitis is an infectious disease, which leads to loss of supporting bone around dental implants. To evaluate the extent and location of bone loss, 43 patients with peri-implantitis were examined. The bone loss was clinically measured at the time of dental surgery. Data revealed that 25% of subjects had bone loss associated with all their implants although the majority of the subjects had fewer than 50% of their implants affected by bone loss. A total number of 264 implants were examined and 131 of those had peri-implantitis associated bone loss. The pattern of bone loss at implants varied between and within subjects and location in the jaws. The highest proportion of implants with peri-implantitis was found in the upper jaw and within this group, at implants located in the incisor area of the upper jaw; the lowest was the canine area of the lower jaw. The highest proportion of implants that lost ≥ 2/3 of their bone support was found in the incisor area of the maxilla. We concluded that in the presence of peri-implant inflammation, bone quantity and characteristics may influence the progression of peri-implantitis bone loss at dental implants. We hypothesize that the ability of the bone to withstand occlusal forces will be altered as consequence of the loss of bone at the neck of the implants. To achieve an understanding of the local degradation of bone due to peri-implantitis, we need to analyze the microstructure of the bone as well the cellular biology of the peri-implant inflammation.  相似文献   

18.
目的:探讨运用偏振光显微镜来观测无菌性松动人工关节假体周围的聚乙烯颗粒分布,评估其在研究磨屑颗粒诱导假体无菌性松动机制及防治措施等实验研究中的可行性。方法:我们用雌性新西兰大白兔建立动物模型,在左侧胫骨髓腔内植入羟基磷灰石(hydroxyapatite,HA)涂层假体。并分别于假体表面和膝关节腔内植入0.5×107超高分子量聚乙烯(Ultra-high molecular weight polyethylene,UHMWPE)颗粒。术后行四环素荧光双标记。膝关节滑膜组织苏木精-伊红(hematoxylin-eosin,HE)染色、骨组织改良丽春红染色后分别用普通光镜和偏振光镜观察,未染色的骨组织行荧光显微镜和偏振光镜观察。结果:在聚乙烯颗粒刺激下,膝关节滑膜组织增生明显,骨-假体结合差,假体周围骨小梁稀疏,偏振光显微镜可清晰显示双折光性的聚乙烯颗粒在膝关节分布于滑膜及其深层结缔组织中,在骨-假体间隙间大量充填,阻碍骨-假体整合。结论:运用偏振光显微镜可以清晰而简便地观察滑膜和假体周围的聚乙烯颗粒分布,与传统实验方法相比,更加直观、简便和经济。  相似文献   

19.
This study combines finite element method and animal studies, aiming to investigate tissue remodelling processes around dental implants inserted into sika deer antler and to develop an alternative animal consuming model for studying bone remodelling around implants. Implants were inserted in the antlers and loaded immediately via a self-developed loading device. After 3, 4, 5 and 6 weeks, implants and surrounding tissue were taken out. Specimens were scanned by μCT scanner and finite element models were generated. Immediate loading and osseointegration conditions were simulated at the implant-tissue interface. A vertical force of 10 N was applied on the implant. During the healing time, density and Young’s modulus of antler tissue around the implant increased significantly. For each time point, the values of displacement, stresses and strains in the osseointegration model were lower than those of the immediate loading model. As the healing time increased, the displacement of implants was reduced. The 3-week immediate loading model (9878 ± 1965 μstrain) illustrated the highest strains in the antler tissue. Antler tissue showed similar biomechanical properties as human bone in investigating the bone remodelling around implants, therefore the use of sika deer antler model is a promising alternative in implant biomechanical studies.  相似文献   

20.
Bone ingrowth into a porous surface is one of the primary methods for fixation of orthopaedic implants. Improved understanding of bone formation and fixation of these devices should improve their performance and longevity. In this study predictions of bone ingrowth into an implant porous coating were investigated using mechano-reculatory models. The mechano-regulatory tissue differentiation algorithm proposed by Lacroix et al., and a modified version that enforces a tissue differentiation pathway by transitioning from differentiation to bone adaptation were investigated. The modified algorithm resulted in nearly the same behavior as the original algorithm when applied to a fracture-healing model. The algorithms were further compared using micromechanical finite element model of a beaded porous scaffold. Predictions of bone and fibrous tissue formation were compared between the two algorithms and to clinically observed phenomena. Under loading conditions corresponding to a press-fit hip stem, the modified algorithm predicted bone ingrowth into approximately 25% of the pore space, which is similar to that reported in experimental studies, while the original algorithm was unstable. When micromotion at the bone-implant interface was simulated, 20 mum of transverse displacement resulted in soft tissue formation at the bone-implant interface and minimal bone ingrowth. In contrast, 10 and 5 mum of micromotion resulted in bone filling 40% of the pore space and a stable interface, again consistent with clinical and experimental observations.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号