首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 437 毫秒
1.
2.
Monoclonal antibodies specific for phycoerythrin (PE) were covalently labeled with the fluorescent dye cyanine 5 (Cy5). Excitation at 488 nm of immune complexes obtained by mixing Cy5-anti-PE with PE resulted in a 4-fold reduction of PE fluorescence measured at 565 nm and an increase of fluorescence measured at 655 nm. The observed energy transfer between PE and Cy5-anti-PE was used to develop three color immunofluorescence staining procedures for flow cytometers equipped with an Argon laser tuned at 488 nm. Mouse IgG1 monoclonal antibodies specific for cell surface antigens were cross-linked with either unlabeled or Cy5 labeled mouse IgG1 anti-PE using F(ab')2 fragments of monoclonal rat anti-mouse IgG1. PE was added to these immune complexes in sufficient amounts to saturate all PE binding sites. Cells were incubated with PE-labeled and PE/Cy5-labeled tetrameric antibody complexes together with FITC labeled antibodies and analyzed by flow cytometry. The emission from FITC, PE and PE/Cy5 could be readily separated and bright three color immunofluorescence staining of mononuclear cells from human peripheral blood and bone marrow was observed. The results of these experiments demonstrate that useful probes for single laser three color staining of cell surface antigens can be readily obtained by mixing of selected reagents. Compared to standard procedures for the covalent labeling of PE (tandem) molecules to antibodies, the non-covalent procedures described in this report provide significant advantages in terms of the amount of reagents, time and equipment required to obtain suitable reagents for three color immunofluorescence staining.  相似文献   

3.
Simultaneous labeling of multiple targets in a single sample, or multiplexing, is a powerful approach to directly compare the amount, localization and/or molecular properties of different targets in the same sample. Here we highlight the robust reliability of the simultaneous use of multiple mouse monoclonal antibodies (mAbs) of different immunoglobulin G (IgG) subclasses in a wide variety of multiplexing applications employing anti-mouse IgG subclass-specific secondary antibodies (2°Abs). We also describe the unexpected finding that IgG subclass-specific 2°Abs are superior to general anti-mouse IgG 2 °Abs in every tested application in which mouse mAbs were used. This was due to a detection bias of general anti-mouse IgG-specific 2°Abs against mAbs of the most common mouse IgG subclass, IgG1, and to a lesser extent IgG2b mAbs. Thus, when using any of numerous mouse mAbs available through commercial and non-profit sources, for cleaner and more robust results each mAb should be detected with its respective IgG subclass-specific 2°Ab and not a general anti-mouse IgG-specific 2°Ab.  相似文献   

4.
Fluorescence is a mainstay of bioanalytical methods, offering sensitive and quantitative reporting, often in multiplexed or multiparameter assays. Perhaps the best example of the latter is flow cytometry, where instruments equipped with multiple lasers and detectors allow measurement of 15 or more different fluorophores simultaneously, but increases beyond this number are limited by the relatively broad emission spectra. Surface enhanced Raman scattering (SERS) from metal nanoparticles can produce signal intensities that rival fluorescence, but with narrower spectral features that allow a greater degree of multiplexing. We are developing nanoparticle SERS tags as well as Raman flow cytometers for multiparameter single cell analysis of suspension or adherent cells. SERS tags are based on plasmonically active nanoparticles (gold nanorods) whose plasmon resonance can be tuned to give optimal SERS signals at a desired excitation wavelength. Raman resonant compounds are adsorbed on the nanoparticles to confer a unique spectral fingerprint on each SERS tag, which are then encapsulated in a polymer coating for conjugation to antibodies or other targeting molecules. Raman flow cytometry employs a high resolution spectral flow cytometer capable of measuring the complete SERS spectra, as well as conventional flow cytometry measurements, from thousands of individual cells per minute. Automated spectral unmixing algorithms extract the contributions of each SERS tag from each cell to generate high content, multiparameter single cell population data. SERS-based cytometry is a powerful complement to conventional fluorescence-based cytometry. The narrow spectral features of the SERS signal enables more distinct probes to be measured in a smaller region of the optical spectrum with a single laser and detector, allowing for higher levels of multiplexing and multiparameter analysis.  相似文献   

5.
BACKGROUND: Measuring CD4 T-cell counts at low cost is relevant in dealing with the human immunodeficiency virus (HIV) epidemic throughout the developing world. The recently introduced novel concepts in gating strategies and sample stabilization facilitate affordable immunophenotyping by flow cytometry. However, the impact of these developments is still limited by the high cost of currently available flow cytometers. METHODS: Diode lasers emitting 10-15 mW at 635 nm are one-tenth the size and cost and require one thousandth the power of an equivalent 488-nm argon ion laser. We used the available 635-nm diode-based flow cytometers, including PA-II, Luminex 100, SuperMot, and FACSCalibur, to investigate whether these instruments can generate reliable CD4 counts when used with allophycocyanin (APC) and cyanin-5 (Cy5)-labeled CD4 antibodies. RESULTS: We document the feasibility of obtaining leucocyte differential counts using orthogonal side scatter (SSC) without the need for forward scatter (FSC). Accurate CD4% values among lymphocytes and leucocytes can be obtained by primary CD4 gating using a single CD4 monoclonal antibody conjugated to APC or Cy5. Double immunofluorescence (IF) staining with CD4-APC (FL1) and CD45-APC-Cy7 (FL2) introduces pan-leucogating for a convenient assessment of absolute CD4 counts on double platforms. We demonstrate that small flow cytometers with laser diodes are capable of delivering absolute CD4 T-cell counts with a precision similar to the performance of the current state-of-the-art single-platform instruments (e.g., the CytoronAbsolute; R(2) = 0.961). In this respect, they appear to be superior to the nonflow CD4 counting techniques. CONCLUSIONS: Accurate CD4 counts can be generated at minimal cost on red diode laser-operated flow cytometers, retaining the potential for high throughput capacity without compromising precision. With further improvements in volumetric technology and clinical software, these cytometers may develop into a new generation of inexpensive battery-operated laboratory hardware that combines cellular phenotyping with bead-based multiplexing immunoassays for (HIV) serology.  相似文献   

6.
Two different fluorescein isothiocyanate (FITC) conjugates were used to analyze the effect of labeling intensity on the flow cytometric appearance of marine dinoflagellates labeled with antibodies that specifically recognized the outer cell wall. Location of the labeling was revealed by epifluorescence and real-time confocal laser scanning microscopy using an anti-rabbit IgG/FITC-conjugated secondary antiserum. Flow cytometric measurements showed that cells of Prorocentrum species labeled this way could not always be distinguished from unlabeled cells. The labeling intensity increased several times when a biotinylated anti-rabbit IgG secondary antiserum was used in combination with a streptavidin/FITC conjugate. Flow cytometry indicated that the labeling intensity had increased 50%, which resulted in an improved separation of clusters of labeled and unlabeled cells.  相似文献   

7.
The single-platform absolute T-lymphocyte subset analysis was evaluated utilizing a universal protocol in a Canadian multicenter study with the collaboration of the members of the Canadian HIV Trials Network (CTN). Participants used flow cytometers and reagents of their choice for labeling and lysing whole blood. Over a 2-year period, CTN laboratories performed single-platform absolute T-lymphocyte subset enumerations on fresh and commercial stabilized blood products using commercially available microfluorospheres TruCount and Flow-Count. This multicenter evaluation demonstrated that the application of a universal template for single-platform analysis provides a generic approach that embraces a wide array of immunophenotyping settings available in clinical laboratory.  相似文献   

8.
Flow cytometry allows high-content, multiparameter analysis of single cells, making it a promising tool for drug discovery and profiling of intracellular signaling. To add high-throughput capacity to flow cytometry, we developed a cell-based multiplexing technique called fluorescent cell barcoding (FCB). In FCB, each sample is labeled with a different signature, or barcode, of fluorescence intensity and emission wavelengths, and mixed with other samples before antibody staining and analysis by flow cytometry. Using three FCB fluorophores, we were able to barcode and combine entire 96-well plates, reducing antibody consumption 100-fold and acquisition time to 5-15 min per plate. Using FCB and phospho-specific flow cytometry, we screened a small-molecule library for inhibitors of T cell-receptor and cytokine signaling, simultaneously determining compound efficacy and selectivity. We also analyzed IFN-gamma signaling in multiple cell types from primary mouse splenocytes, revealing differences in sensitivity and kinetics between B cells, CD4+ and CD4- T cells and CD11b-hi cells.  相似文献   

9.
The ZAP-70 protein is a member of the Syk/ZAP protein tyrosine kinase family, normally expressed in T cells and NK cells but not found in normal, mature B cells. The protein plays a critical role in the initiation of T-cell signaling. Leukemic cells from patients with B-cell chronic lymphocytic leukemia (B-CLL) that expressed nonmutated immunoglobulin V genes were found to express levels of ZAP-70 protein that were comparable to those detected in T cells of healthy adults. The ZAP-70 protein expression can be evaluated by flow cytometry and may be used as a prognostic marker in B-CLL patients. We modified the method of immunocytochemical assessment of ZAP-70 expression. The traditional two-step method with monoclonal anti-ZAP-70 antibody in the first step followed by FITC-conjugated goat anti-mouse IgG was changed for one-step method with monoclonal anti-ZAP-70 antibody labeled by Zenon Alexa Fluor 488. The method is simple and fast. The major advantage of Zenon labeling technique is its compatibility with simultaneous staining of surface antigens. The cells may be earlier immunostained for CD3, CD19 and/or CD5 to compare of the ZAP-70 kinase expression in B and T cells.  相似文献   

10.
Biochemical studies have demonstrated that phosphorylation of lymphocyte cell kinase (p56(lck) ) is crucial for activation of signaling cascades following T cell receptor (TCR) stimulation. However, whether phosphorylation/dephosphorylation of the activating or inhibitory tyrosine residues occurs upon activation is controversial. Recent advances in intracellular staining of phospho-epitopes and cytometric analysis, requiring few cells, have opened up novel avenues for the field of immunological signaling. Here, we assessed p56(lck) phosphorylation, using a multiparameter flow-cytometric based detection method following T cell stimulation. Fixation and permeabilization in conjunction with zenon labeling technology and/or fluorescently labeled antibodies against total p56(lck) or cognate phospho-tyrosine (pY) residues or surface receptors were used for detection purposes. Our observations showed that activation of Jurkat or primary human T cells using H(2) O(2) or TCR-induced stimulation led to simultaneous phosphorylation of the activating tyrosine residue, Y394 and the inhibitory tyrosine residue, Y505 of p56(lck) . This was followed by downstream calcium flux and expression of T cell activation markers; CD69 and CD40 ligand (CD40L). However, the extent of measurable activation readouts depended on the optimal stimulatory conditions (temperature and/or stimuli combinations). Treatment of cells with a p56(lck) -specific inhibitor, PP2, abolished phosphorylation at either residue in a dose-dependent manner. Taken together, these observations show that TCR-induced stimulation of T cells led to simultaneous phosphorylation of p56(lck) residues. This implies that dephosphorylation of Y505 is not crucial for p56(lck) activity. Also, it is clear that cytometric analysis provides for a rapid, sensitive, and quantitative method to supplement biochemical studies on p56(lck) signaling pathways in T cells at single cell level. ? 2012 International Society for Advancement of Cytometry.  相似文献   

11.
Martin K  Hart C  Liu J  Leung WY  Patton WF 《Proteomics》2003,3(7):1215-1227
Three-color fluorescence detection methods are described based upon covalently coupling the dye 2-methoxy-2,4-diphenyl-2(2H)-furanone (MDPF) to proteins immobilized on poly(vinylidene difluoride) (PVDF) membranes, followed by detection of target proteins using alkaline-phosphatase-conjugated reporter molecules in combination with the fluorogenic substrate 9H-(1,3-dichloro-9,9-dimethylacridin-2-one-7-yl) phosphate (DDAO-phosphate) as well as horseradish peroxidase-conjugated reporter molecules in combination with the new fluorogenic substrate Amplex Gold reagent. This results in all proteins in the profile being visualized as fluorescent blue signal, those detected specifically with the alkaline phosphatase conjugate appearing as fluorescent red signal and those detected specifically with the horseradish peroxidase conjugate appearing as fluorescent yellow signal. Using conventional secondary antibodies, two different targets may be identified as long as primary antibodies generated from two different species are used in the analysis. However, Zenon antibody labeling technology eliminates this restriction, permitting the simultaneous use of two different mouse monoclonal antibodies or two different rabbit polyclonal antibodies in the same electroblotting experiment. The trichromatic detection system is broadly compatible with UV epi-illuminators combined with photographic or charge-coupled device (CCD) cameras, and xenon-arc sources equipped with appropriate excitation/emission filters. Alternatively, the enzyme conjugates may be detected using a laser-based gel scanner. The trichromatic method permits detection of low nanogram amounts of protein and allows for unambiguous identification of two different target proteins relative to the entire protein profile on a single electroblot, precluding any requirement for running replicate gels that would otherwise require separate visualization of total proteins and subsequent alignment with multiple chemiluminescent or colorimetric signals generated on different electroblots.  相似文献   

12.
A method for the determination of circulating immune complexes (CIC) was adapted for flow cytometric analysis. Human granulocytes were used to phagocytose IgG-bearing CIC of serum from systemic lupus erythematosus (SLE) patients. A method for labeling the phagocytosed CIC with FITC-conjugated anti-human IgG was developed where the granulocytes remain in suspension during fixation and labeling. The fluorescence per cell, measured with a flow cytometer, is a measure of the total amount of the phagocytosed IgG. The results indicate that a rapid and quantitative method for the detection and measurement of phagocytosed CIC is possible using the flow cytometer.  相似文献   

13.
A technique of fluorescence multiplexing is described for analysis of the plasma membrane proteome of colorectal cancer cells from surgically resected specimens, enabling detection and immunophenotyping when the cancer cells are in the minority. A single-cell suspension was prepared from a colorectal tumour, and the mixed population of cells was captured on a CD antibody microarray. The cancer cells were detected using a fluorescently tagged antibody for carcinoembryonic antigen (CEA-Alexa647) or epithelial cell adhesion marker (EpCAM-Alexa488). Using this multiplexing procedure, dot patterns from colorectal cancers were distinct from those of adjacent normal tissue. Subtraction of the expression levels for each antigen from normal tissue from those for the cancer shows differential expression in the cancer of CD66c, CD15s, CD55, CD45, CD71, CD45RO, CD11b and CEA, in descending order. Cells captured on the same microarray were also labelled with fluorescent CD3-phycoerythrin antibody revealing the presence of tumour-infiltrating lymphocytes. The immunophenotypes of T lymphocytes from the tumour samples showed differential expression of HLA-DR, TCR alpha/beta, CD49d, CD52, CD49e, CD5, CD95, CD28, CD38 and CD71, in descending order. Fluorescence multiplexing of mixed cell populations captured on a single antibody microarray enables expression profiling of multiple sub-populations of cells within a tumour sample.  相似文献   

14.
BACKGROUND: Current methods for multiparameter DNA flow cytometry suffer from several limitations. These include significant modifications of cell morphological parameters, the impossibility to counterstain cells with certain fluorochromes, and laborious tuning of the instrument that, for some procedures, must be equipped with an ultraviolet (UV) laser. To overcome these problems, we developed a novel method for the simultaneous analysis of morphological parameters, four-color immunophenotyping, and stoichiometric DNA labeling using a bench-top flow cytometer. METHODS: The method consists of a mild permeabilization/fixation treatment at room temperature, followed by labeling with fluorochrome-conjugated monoclonal antibodies (mAbs) and with the DNA dye 7-aminoactinomycin D (7-AAD) at 56 degrees C. RESULTS: Using this method, we analyzed resting peripheral blood mononucleated cells (PBMC), proliferating T cells cultured in the presence of interleukin-2 (IL-2), and lymphoblastoid B cells. Lymphocytes, monocytes, and lymphoblasts treated by this procedure retained differential light scattering (DLS) characteristics virtually identical to those of untreated cells. This allowed regions to be drawn on forward scatter (FSC) and side scatter (SSC) cytograms resolving different cell populations. DLS were preserved well enough to distinguish large lymphoblasts in the S or G2/M phases from small G0/G1 cells. Also, stainability with fluorescein-isothiocyanate (FITC), R-phycoerythrin (PE), allophycocyanin (APC)-conjugated mAbs was generally preserved. DNA labeling with 7-AAD was of quality good enough to permit accurate cell cycle analysis. CONCLUSIONS: The method described here, which we called integral hot staining (IHS), represents a very simple, reproducible, and conservative assay for multiparameter DNA analysis using a bench-top flow cytometer. Last but not least, the cytometer tuning for multiparameter acquisition is straightforward.  相似文献   

15.
C C Stewart  S J Stewart 《Cytometry》1999,38(4):161-175
Four-color immunophenotyping can now be routinely performed using either a single laser or dual laser flow cytometer. When a single laser instrument is used, the fluorochromes evaluated are usually FITC, PE, PE-TR and PE-CY5 (or PerCP). For two-laser excitation APC is generally used in place of PE-TR. Since each tandem dye construct contains PE, three of the four detectors are affected and compensation can be problematic. In this report we show that each tandem conjugated antibody, whether different batches from the same supplier or conjugates from different suppliers all require unique compensation. This inconsistency results in erroneous data, negates the use of single labeled particles as a method for providing adequate compensation and requires dual and triple labeled cells of known pattern to verify compensation. It is also shown that improper compensation can reduce or eliminate completely the detection of fluorescence emission from PECY5 conjugated antibodies. These problems are caused by a variation in energy transfer between PE and either TR or CY5 because the chemistry involved in preparation and conjugation to antibodies is not sufficiently controlled to produce reagents with uniform compensation requirements. The variation in tandem dye compensation can be addressed by either using the same tandem conjugated antibody, by using the same second step tandem reagent to an appropriate first step antibody or by using software compensation. The latter provides an easy solution because a unique compensation matrix can be produced for each antibody tandem conjugate.  相似文献   

16.
Pathogen detection using biosensors is commonly limited due to the need for sensitivity and specificity in detecting targets within mixed populations. These issues were addressed through development of a dual labeling method that allows for both liquid-phase fluorescence in situ hybridization (FISH) and capture antibody targeted detection (CAT-FISH). CAT-FISH was developed using Escherichia coli O157:H7 and Staphylococcus aureus as representative bacteria, and processing techniques were evaluated with regard to FISH intensities and antibody recognition. The alternative fixative solution, methacarn, proved to be superior to standard solid-phase paraformaldehyde fixation procedures, allowing both FISH labeling and antibody recognition. CAT-FISH treated cells were successfully labeled with FISH probes, captured by immunomagnetic separation using fluorescent cytometric array beads, and detected using a cytometric array biosensor. CAT-FISH treated cells were detectable with LODs comparable to the standard antibody-based technique, (~ 103 cells/ml in PBS), and the technique was also successfully applied to two complex matrices. Although immunomagnetic capture and detection using cytometric arrays were demonstrated, CAT-FISH is readily applicable to any antibody-based fluorescence detection platform, and further optimization for sensitivity is possible via inclusion of fluorescently tagged antibodies. Since the confidence level needed for positive identification of a detected target is often paramount, CAT-FISH was developed to allow two separate levels of specificity, namely nucleic acid and protein signatures. With proper selection of FISH probes and capture antibodies, CAT-FISH may be used to provide rapid detection of target pathogens from within complex matrices with high levels of confidence.  相似文献   

17.
Development of an ultrasensitive biosensor for biological hazards in the environment is a major need for pollutant control and for the detection of biological warfare. Fluorescence methods combined with immunodiagnostic methods are the most common. To minimize background noise, arising from the unspecific adsorption effect, we have adapted the FRET (frequency resonance energy transfer) effect to the immunofluorescence method. FRET will increase the selectivity of the diagnosis process by introducing a requirement for two different reporter molecules that have to label the antigen surface at a distance that will enable FRET. Utilizing the multiparameter capability of flow cytometry analysis to analyze the double-labeling/FRET immunostaining will lead to a highly selective and sensitive diagnostic method. This work examined the FRET interaction of fluorescence-labeled avidin molecules on biotin-coated microspheres as a model system. As target system, we have used labeled polyclonal antibodies on Bacillus anthracis spores. The antibodies used were purified immunoglobulin G (IgG) molecules raised in rabbits against B. anthracis exosoporium components. The antibodies were fluorescence labeled by a donor-acceptor chromophore pair, alexa488 as a donor and alexa594 as an acceptor. On labeling the spores with alexa488-IgG as a donor and alexa594-IgG as an acceptor, excitation at 488 nm results in quenching of the alexa-488 fluorescence (E(q) = 35%) and appearance of the alexa594 fluorescence (E(s) = 22%), as detected by flow cytometry analysis. The FRET effect leads to a further isolated gate (FL1/FL3) for the target spores compared to competitive spores such as B. thuringiensis subsp. israelensis and B. subtilis. This new approach, combining FRET labeling and flow cytometry analysis, improved the selectivity of the B. anthracis spores by a factor of 10 with respect to B. thuringiensis subsp. israelensis and a factor of 100 with respect to B. subtilis as control spores.  相似文献   

18.
The binding and stabilization capacity of potential T cell epitopes to class I MHC molecules form the basis for their immunogenicity and provide fundamental insight into factors that dictate cellular immune responses. We have developed a versatile high throughput cell-free method to measure MHC stability by capturing a variety of MHC products on the surface of streptavidin-coated particles followed by flow cytometry analysis. Arrays of peptide-MHC combinations, generated by exchanging conditional ligand-loaded MHC, could be probed in a single experiment, thus combining the molecular precision of biochemically purified MHCs with high content multiparametric flow cytometry-based assays. Semiquantitative determination of the peptide affinity for the restriction element could also be accomplished through competition experiments using this bead-based assay. Furthermore, the generated peptide-MHC reagents could directly be applied to antigen-specific CD8(+) T lymphocyte analysis. The combinatorial labeling of beads allowed straightforward identification by their unique fluorescent signatures and provided a convenient means for extended assay multiplexing.  相似文献   

19.
Abnormalities in lymphocyte signaling cascades are thought to play an important role in the development of autoimmune disease. However, the large amount of cellular material needed for standard biochemical assessment of signaling status has made it difficult to evaluate putative abnormalities completely using primary lymphocytes. The development of technology to employ intracellular staining and flow cytometry to assess the signaling status of individual cells has now made it possible to delineate the perturbations that are present in lymphocytes from patients with autoimmune disease. As an example, human B cells from the Ramos B cell line and the periphery of systemic lupus erythematosus (SLE) patients or normal nonautoimmune controls were assessed for activation of the NF-kappaB and mitogen activated protein kinase (MAPK) signaling cascades by intracellular multiparameter flow cytometric analysis and biochemical Western blotting. In combination with fluorochrome conjugated antibodies specific for surface proteins that define B cell subsets, antibodies that recognize activated, or phosphorylated inhibitors of kappaB (IkappaB) as well as the extracellular regulated kinase (ERK), jun N-terminal kinase (JNK) or p38 MAPKs were used to stain fixed and permeabilized human B cells and analyze them flow cytometrically. Examination of the known signaling pathways following engagement of CD40 on human B cells confirmed that intracellular flow cytometry and Western blotting equivalently assay CD154-induced phosphorylation and degradation of IkappaB proteins as well as phosphorylation of the MAPKs ERK, JNK and p38. In addition, B cells from the periphery of SLE patients had a more activated status immediately ex vivo as assessed by intracellular flow cytometric analysis of phosphorylated ERK, JNK and p38 when compared with B cells from the periphery of normal, nonautoimmune individuals. Together, these results indicate that multiparameter intracellular flow cytometric analysis of signaling pathways, such as the NF-kappaB and MAPK cascades, can be used routinely to assess the activation status of a small number of cells and thus delineate abnormalities in signaling molecules expressed in primary lymphocytes from patients with autoimmune disease.  相似文献   

20.
Multistation multiparameter flow cytometry: a critical review and rationale   总被引:6,自引:0,他引:6  
H M Shapiro 《Cytometry》1983,3(4):227-243
The capacity for fluorescence excitation by beams of different wavelengths at separate points along the sample stream, and the capacity for computer analysis of multiparameter data thus obtained, are now available in flow cytometer/sorter systems from commercial producers. It is now readily apparent to most experienced users of flow cytometers that such multiparameter analysis offers the most convenient solution to the problem of characterizing subpopulations of cells within a mixed population. The use of multiple beams facilitates resolution of fluorescence signals from several probes within or upon a single cell and widens the range of analytical alternatives available to experimenters. This critical review discusses the history of the instrumentation, the parameters now measurable and the probes used for their measurement, and the methods for data analysis. Required sensitivity and precision are discussed, leading to the conclusion that many of the advantages of multistation, multiparameter flow cytometry can be made available in less complex and less costly instruments using less powerful sources and less elaborate computer hardware than are presently incorporated in commercial apparatus.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号