首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
We describe the docking of selected steroidal and non-steroidal estrone sulphatase inhibitors, including the Phase I clinical trial candidate 667COUMATE (6), into the active site of human carbonic anhydrase II (hCA II). The docking scores are compared with the inhibition of hCA II and show good correlation with biological activity.  相似文献   

2.
The endogenous oestrogen metabolite, 2-methoxyoestradiol (2-MeOE2) inhibits the growth of breast cancer cells and is also a potent anti-angiogenic agent. We have previously shown that the 3-sulphamoylated derivatives of 2-methoxyoestrogens are more potent than the non-sulphamoylated compounds. In this study, we have compared the abilities of 2-methoxyoestradiol-bis-sulphamate (2-MeOE2bisMATE) and 2-MeOE2 to inhibit the growth of MCF-7 breast cancer cells. Both compounds inhibited cell growth with the IC(50) for 2-MeOE2bisMATE (0.4 microM) being six-fold lower than that for 2-MeOE2 (2.5 microM). Oestrogen sulphamates are potent inhibitors of steroid sulphatase (STS) activity. 2-MeOE2bisMATE was found to retain its STS inhibitory activity and in a placental microsome assay system it was equipotent with oestrone-3-O-sulphamate (EMATE). An in vivo study was also carried out to compare the potency of 2-MeOE2bisMATE with that of EMATE and the non-steroidal STS inhibitor, 667 coumarin sulphamate (667 COUMATE). After a single oral dose (10mg/kg) some recovery of STS activity was detected by day 3 (10%) with activity partially restored (55%) by day 7 after administration of 667 COUMATE. For the other two steroidal compounds, STS activity remained almost completely inactivated for up to 5 days with complete restoration of activity occurring by day 15. The anti-proliferative and STS inhibitory properties of 2-MeOE2bisMATE suggest that it has considerable potential for development as a novel anti-cancer drug.  相似文献   

3.
Carbonic anhydrases (CAs) are expressed by many solid tumours where they may act to confer a growth advantage on malignant tissues. In this study we have examined the ability of a series of steroidal and non-steroidal sulphamates (originally developed as steroid sulphatase inhibitors) and related compounds to inhibit human CAII (hCAII) activity in vitro. Using a 96-well plate assay, oestrone-3-O-sulphamate (EMATE) and two coumarin-based sulphamate drugs (667 COUMATE and STX 118) were found to have IC(50) values of 25-59 nM for the inhibition of hCAII activity. These compounds therefore have a similar CAII inhibitory potency to that of acetazolamide (IC(50)=25 nM), a known hCAII inhibitor. Docking studies have been performed with selected compounds to the crystal structure of hCAII and excellent correlation of scores with biological activity was observed. This agrees with our recent observations when we were the first to report the inhibition of hCAII by STS inhibitors. These studies and initial results with docking to the crystal structure of the extracellular domain of hCAXII indicate that the STS sulphamate ester inhibitors should also be interesting candidates to pursue as inhibitors of CA isozymes that are over-expressed in human tumours.  相似文献   

4.
Nitric oxide reacts rapidly with superoxide to form the strong nitrating agent peroxynitrite, which is responsible for much of the tissue damage associated with diverse pathophysiological conditions such as inflammation. The occurrence of free or protein-bound nitrotyrosine (NTYR) has been considered as evidence for in vivo formation of peroxynitrite. However, various agents can nitrate tyrosine, and their relative significance in vivo has not been determined due to lack of a sensitive method to analyze NTYR in tissue proteins and biological fluids. We have developed a new HPLC-electrochemical detection method to analyze NTYR in protein hydrolyzates or biological fluids. The sample is injected directly into a reversed-phase HPLC column and NTYR is subsequently reduced by a platinum column to 3-aminotyrosine, which is quantified with an electrochemical detector. The method is simple, selective, and sensitive (detection limit, 0.1 pmol per 20-microl injection). We have applied this method to compare in vitro the ability of various nitrating agents to form NTYR in bovine serum albumin and human plasma. Yields of NTYR formed in human plasma proteins incubated with 1 or 10 mM nitrating agent decreased in the following order: synthetic peroxynitrite > 3-morpholinosydonimine, a generator of both NO and superoxide > Angeli's salt, which forms nitroxyl anion (NO-) > spermine-NONOate, which releases NO > sodium nitrite plus hypochlorite, which forms the nitrating agent nitryl chloride (NO2Cl). A simple purification method using a C18 Sep-Pak cartridge is also described for analysis of free NTYR in human plasma.  相似文献   

5.
Three phase liquid phase microextraction (three phase LPME) technique coupled with HPLC-UV has been applied as a sensitive and efficient sample preparation method to determine phenylacetic acid (PAA) as a biomarker of depressive disorders and phenylpropionic acid (PPA) in biological fluids. The compounds were extracted from 3.0 ml aqueous solution with the adjustment of pH at a fixed value in the range of 2.0-3.5 (donor solution) into an organic phase (1-hexanol) layered on the surface of the donor solution and finally back-extracted into 4.0 microl of the acceptor microdrop (pH 11.1) located at the end of the microsyringe needle. After a prescribed back-extraction time, the acceptor microdrop was withdrawn into the microsyringe and then directly injected into the HPLC system. In order to achieve maximum extraction efficiency, different parameters affecting the extraction conditions were optimized. At the optimum conditions (donor solution: 2.3M Na(2)SO(4), pH 2.0-3.5; organic membrane: 95 microl of 1-hexanol; acceptor solution: 4.0 microl of 0.1M NH(3)/NH(4)(+) with pH 11.1; donor solution temperature: 45-50 degrees C; extraction time: 20 min and back-extraction time: 12 min), up to 110-fold enrichment factor was obtained. The calibration curve for these analytes was linear in the range of 1-5000 microg/l with r(2)>0.998. The intraday and interday RSD% were below 6.5% and the limits of detection (LODs) for both analytes were 0.2 microg/l (based on S/N=3). The proposed technique is a low cost, simple and sensitive method with highly clean-up effect. Finally, this technique was successfully utilized for the detection of target analytes in human urine, serum and plasma.  相似文献   

6.
The identification of the active pharmacophore required for potent inhibition of steroid sulphatase activity, i.e. an aryl-O-sulphamate structure, has led to the synthesis and testing of a large number of 1–4 ring-based inhibitors. 4-Methylcoumarin-7-O-sulphamate (COUMATE) was one of the first non-steroid based inhibitors identified. In an attempt to increase the potency of this class of inhibitor a series of tricyclic COUMATEs (665–6615 COUMATEs) have been synthesised and evaluated. Using placental microsomes as a source of oestrone sulphatase (E1-STS) the size of the third ring of the tricyclic COUMATEs was found to have a marked effect on inhibitor potency. Whereas 665- and 6615-COUMATEs had IC50s of 200 and 370 nM, respectively, the most potent inhibitor in vitro in this series was 6610 COUMATE with an IC50 of 1 nM. Selected inhibitors were tested for their in vivo potency by administration of a single dose (0.1 or 1 mg/kg, p.o.) to female rats. Surprisingly, in vivo 6615 COUMATE proved to be the most active drug, inhibiting rat liver E1-STS activity by 23 and 94% when assayed 24 h after administration of the 0.1 and 1 mg/kg doses. E1-STS activity in brain tissue and white blood cells was also found to be inhibited when selected drugs were tested. These studies have identified a number of tricyclic COUMATEs with therapeutic potential.  相似文献   

7.
A sensitive and selective HPLC method with UV detection (290 nm) was developed and validated for quantitation of pantoprazole, proton-pump inhibitor, in human plasma. Following a single-step liquid-liquid extraction with methyl tert-butyl ether/diethyl ether (70/30, v/v), the analyte and internal standard (zonisamide) were separated using an isocratic mobile phase of 10mM phosphate buffer (pH 6.0)/acetonitrile (61/39, v/v) on reverse phase Waters symmetry C18 column. The lower limit of quantitation was 20 ng/mL, with a relative standard deviation of less than 4%. A linear range of 20-5000 ng/mL was established. This HPLC method was validated with between-batch and within-batch precision of 1.3-3.2% and 0.7-3.3%, respectively. The between-batch and within-batch bias was -0.5 to 8.2 % and -2.5 to 12.1%, respectively. This validated method is sensitive and repeatable enough to be used in pharmacokinetic studies.  相似文献   

8.
In an effort to investigate the structural requirements for the inhibition of the enzyme oestrone sulphatase (ES), we have previously undertaken extensive structure-activity relationship studies. Using the data from molecular modelling and structure–activity relationship determination studies, we have designed a number of compounds based upon 4-sulphamated phenyl ketones. Here, we report the results of our study into a series of these compounds as potential inhibitors of ES. The results of the study show that these compounds are potent inhibitors the possessing greater inhibitory activity than 4-methylcoumarin-7-O-sulphamate derivative (COUMATE) (a potent non-steroidal inhibitor), but are weaker than oestrone-3-sulphamate (EMATE) and the recently reported 667- and 669-COUMATE, however, they provide good lead compounds in the search for potent inhibitors of ES. Furthermore, the compounds are observed to be irreversible inhibitors. From the consideration of the structure-activity relationship of these novel compounds, we have attempted to rationalise the significance of the log P factor in the inhibition of ES and suggest that a log P requirement of approximately 3.5 aids the inhibition through the rapid expulsion of the carbon backbone from the active site. We also propose that the same factor is responsible for the hydrolysis of oestrone sulphate reaction, appearing to be an irreversible process.  相似文献   

9.
A sensitive HPLC method has been developed for the assay of aciclovir and ganciclovir in human plasma, by HPLC coupled with spectrofluorimetric detection. Plasma (1000 microl), with 9-ethyl-guanine added as internal standard, is submitted to protein precipitation with trichloroacetic acid solution 20%. The supernatant, evaporated to dryness at 37 degrees C, is reconstituted in 100 microl of a solution of sodium heptanosulfonate 0.4% adjusted with acetic acid to pH 2.60 and a 30 microl volume is then injected onto a Nucleosil 100-5 microm C18 column. Aciclovir and ganciclovir are analysed by spectrofluorimetric detection set at 260 nm (excitation) and 380 nm (emission) using a gradient elution program with solvents constituted of acetonitrile and a solution of sodium heptanosulfonate 0.4% adjusted to pH 2.60. The calibration curves are linear between 0.1 and 10 microg/ml. The mean absolute recovery of aciclovir and ganciclovir are 99.2+/-2.5 and 100.3+/-2.5%, respectively. The method is precise (with mean inter-day C.V.s within 1.0-1.6% for aciclovir and 1.2-3.5% for ganciclovir), and accurate (range of inter-day deviations -1.6 to +1.6% for aciclovir and -0.4 to -1.4% for ganciclovir). The method has been applied in stability studies of ganciclovir in patients' blood samples, demonstrating its good stability in plasma at -20 degrees C and at room temperature. The distribution of ganciclovir and aciclovir in plasma and red blood cells was also investigated in vitro in spiking experiments with whole blood, which showed an initial drop of ganciclovir and aciclovir levels in plasma (about -25%) due to the cellular uptake of aciclovir and ganciclovir by red blood cells. The method has been validated and is currently applied in a clinical study assessing the ganciclovir plasma concentration variability after administration of valganciclovir in a population of solid organ transplant patients.  相似文献   

10.
The development of the HIV protease inhibitor saquinavir (Ro 31-8959) required a range of analytical methods for its measurement in biological fluids. This paper describes the development of isocratic, reverse-phase HPLC/UV methods for the routine measurement of plasma levels of the drug together with a more sensitive radioimmunoassay. The performance of the two assays is compared with that of an HPLC/MS/MS method previously published and has been shown to be satisfactory, with coefficients of variation of calibration standards and quality control samples within the usual outside limits of +/- 15%. The HPLC/UV method can be routinely applied for concentrations down to 10-20 ng/ml and a lower limit of quantification of 1 ng/ml from 1 ml of human plasma is possible. The radioimmunoassay was developed for the specific measurement of saquinavir concentrations in human, HIV-positive plasma samples and has a lower limit of quantification of 0.5-1.0 ng/ml. Some preliminary findings suggested that it might not be specific in rat plasma and no attempts have been made to quantify any nonclinical samples with this technique. If still greater sensitivity is required, recourse can be made to the HPLC/MS/MS assay.  相似文献   

11.
A simple high-performance liquid chromatography method for the determination of the antiviral agent ribavirin in human plasma was developed and validated. The method involved solid-phase extraction on phenyl boronic acid cartridges, a reversed-phase liquid chromatography with a Waters Atlantis dC18 (150 mm x 3.9 mm, 5 microm) column and a mobile phase consisting of 10 mM potassium phosphate buffer (pH 4.0), and ultraviolet detection at 207 nm. This assay proved to be sensitive (lower limit of quantification of 0.05 microg/ml), linear (correlation coefficients >or=0.997), specific (no interference with various potentially co-administrated drugs), reproducible (both intra-day and inter-day coefficients of variation 相似文献   

12.
Simple and sensitive high-performance liquid chromatography (HPLC) assays were developed and validated for the quantitation of the investigational anticancer drug 9-nitrocamptothecin (9-NC) as the lactone form and as the total of the lactone(I) and carboxylate(II) forms in human plasma. For the assay of lactone form (9NC-lac), the analytical method involved a protein precipitation step with adding a mixture of cold acetonitril-chloroform (5:1 (v/v), -20 degrees C) to plasma sample that stabilized the pH-dependent conversion of I to II. After evaporation under gentle stream of nitrogen gas (40 degrees C) the dry extract was dissolved in mobile phase (pH 5.5). For determination of the total of the lactone and carboxylate forms of the drug (9NC-tot), plasma samples were deproteinated with cold acetonitril (-20 degrees C) acidified with perchloric acid (5%), which resulted in the conversion of the carboxylate into the lactone form. After centrifugation the upper solvent was evaporated (nitrogen, 40 degrees C) and the dry extract was dissolved in mobile phase (pH 3.5). All separations were performed on a RP-C(8) column, using a mixture of acetonitril-water as eluent (pH 3.5 for total form and pH 5.5 for lactone form) and UV detection. The presented assay was linear over a concentration range of 25-1500 ng/ml with lower limit of quantitation of 25 ng/ml for both 9NC-tot and 9NC-lac. Within-run and between-run precision was always less than 7.5% in the concentration range of interest. The reported assay method showed good characteristics of linearity, sensitivity, selectivity and precision allowing applying in pharmacokinetic studies.  相似文献   

13.
In contrast to aromatase inhibitors, which are now in clinical use, the development of steroid sulphatase (STS) inhibitors for breast cancer therapy is still at an early stage. STS regulates the formation of oestrone from oestrone sulphate (E1S) but also controls the hydrolysis of dehydroepiandrosterone sulphate (DHEA-S). DHEA can be reduced to 5-androstenediol (Adiol), a steroid with potent oestrogenic properties. The active pharmacophore for potent STS inhibitors has now been identified, i.e. a sulphamate ester group linked to an aryl ring. This has led to the development of a number of STS inhibitors, some of which are due to enter Phase I trials in the near future. Such first generation inhibitors include the tricyclic coumarin-based 667 COUMATE. Aryl sulphamates, such as 667 COUMATE, are taken up by red blood cells (rbc), binding to carbonic anhydrase II (CA II), and transit the liver without undergoing first-pass inactivation. 667 COUMATE is also a potent inhibitor of CA II activity with an IC50 of 17 nM. Second generation STS inhibitors, such as 2-methoxyoestradiol bis-sulphamate (2-MeOE2bisMATE), in addition to inhibiting STS activity, also inhibit the growth of oestrogen receptor negative (ER) tumours in mice and are anti-angiogenic. As the active pharmacaphores for the inhibition of aromatase and STS are now known it may be possible to develop third generation inhibitors that are capable of inhibiting the activities of both enzymes. Whilst exploring the potential of such a strategy it was discovered that 667 COUMATE possessed weak aromatase inhibitory properties with an IC50 of 300 nM in JEG-3 cells. The identification of potent STS inhibitors will allow the therapeutic potential of this new class of drug to be explored in post-menopausal women with hormone-dependent breast cancer. Second generation inhibitors, such as 2-MeOE2bisMATE, which also inhibit the growth of ER tumours should be active against a wide range of cancers.  相似文献   

14.
A simple, sensitive and specific HPLC method with UV detection (210 nm) was developed and validated for quantitation of Valdecoxib in human plasma, the newest addition to the group of non-steroidal anti-inflammatory drugs-a highly selective cyclooxygenase-2 inhibitor. The analyte and an internal standard (Rofecoxib) were extracted with diethyl ether/dichloromethane (70/30 (v/v)). The chromatographic separation was performed on reverse phase ODS-AQ column with an isocratic mobile phase of water/methanol (47/53 (v/v)). The lower limit of quantitation was 10 ng/ml, with a relative standard deviation of <20%. A linear range of 10-500 ng/ml was established. This HPLC method was validated with between-batch and within-batch precision of 1.27-7.45 and 0.79-6.12%, respectively. The between-batch and within-batch bias was 0.74-7.40 and -0.93 to 7.70%, respectively. Frequently coadministered drugs did not interfere with the described methodology. Stability of Valdecoxib in plasma was excellent, with no evidence of degradation during sample processing (autosampler) and 30 days storage in a freezer. This validated method is suitable for bioequivalence studies following single dose in healthy volunteers.  相似文献   

15.
A highly sensitive procedure for determining ascorbic acid (AA) and dehydroascorbic acid (DHAA) by high-performance liquid chromatography with electrochemical detection in biological fluids, tissues, and foods is described. AA is separated in a C18 reverse-phase column after extraction from the sample with metaphosphoric acid. An aliquot of 20 microliter of diluted extract is injected into the column for the estimation of AA. DHAA is indirectly estimated by converting it to AA after reduction with DL-homocysteine at pH 7.0-7.2 for 30 min at 25 degrees C. After dilution, a 20-microliter aliquot is injected into the column to obtain total vitamin C (AA + DHAA). The concentration of DHAA is calculated by subtraction. AA can be reproducibly quantified at concentrations as low as 50 pg/20 microliter of sample extract. The method described here used a specially designed mobile phase, gave greater stability and a noiseless baseline, and increased substantially the sensitivity and precision. The procedure is rapid, analysis being completed within 10 min after sample preparation, and has been successfully applied to biological fluids, tissues, and foods.  相似文献   

16.
A reversed-phase (RP) high-performance liquid chromatographic (HPLC) method with fluorescence detection allowing the sensitive and specific quantification of BAY 12-8039, a new antimicrobially active 8-methoxyquinolone, in biological fluids is described. The method is compared to a microbiological assay (bioassay) based on B. subtilis test strain with a limit of quantification of approximately 60 μg/l. Following dilution and centrifugation, plasma, saliva or urine supernatant is directly injected onto the HPLC system. Concentrations down to a limit of quantification of 2.5 μg/l can be quantified in plasma, saliva and urine. Data on recovery, accuracy and precision of the method throughout the whole working range as well as results on stability of the analyte are presented. The concentration data are correlated with results from the bioassay. BAY 12-8039 is stable in plasma after repeated freeze-thaw cycles and following storage at −20°C for at least 12 months. The results of HPLC measurements excellently agree with bioassay data indicating the relevance of the method as a tool in clinical development to answer pharmacokinetic questions related to antimicrobial activity. The method was applied to human plasma, saliva and urine from subjects after a single oral dose of 400 mg of BAY 12-8039.  相似文献   

17.
A direct and selective HPLC method with refractometric detection was worked out for determination of treosulfan in plasma and urine of children. Before injection onto reverse phase column plasma samples with treosulfan and barbital (I.S.) were clarified using filtration. The mobile phase was composed of phosphate buffer, pH 5 and acetonitrile. The linear range of the standard curve of treosulfan spanned concentrations of 10.0-2000.0 microg/ml and 50.0-10000.0 microg/ml in plasma and urine, respectively, and covered the levels found in biological fluids after infusion of the drug. The limit of detection amounted to 5 microg/ml for plasma and 25 microg/ml for urine. Intra- and inter-day precision and accuracy of the measurement fulfilled analytical criteria accepted in pharmacokinetic studies. Recovery of treosulfan as well as stability in biological fluids was also calculated. The validated method was successfully applied in pharmacokinetic studies of treosulfan administered to children prior to haematopoietic stem cell transplantation. Differences between pharmacokinetics of treosulfan in children and adults were also studied.  相似文献   

18.
An HPLC method was developed and validated for the determination of mifepristone in human plasma. C(18) solid-phase extraction cartridges were used to extract plasma samples. Separation was by C(18) column; mobile phase, methanol-acetonitrile-water (50:25:25, v/v/v); flow rate, 0.8 ml/min; UV detection at 302 nm. The calibration curve was linear in the concentration range of 10 ng/ml to 20 microg/ml (r=0.9991). Within- and between-day variability were acceptable. The limit of detection for the assay was 6 ng/ml. Plasma samples were stable for at least 7 days in the state of plasma or residue treated at -20 degrees C. The method was simple, sensitive and accurate, and allowed to determine ng mifepristone in human plasma. It could be applied to assess the plasma level of mifepristone in women receiving low oral doses of mifepristone.  相似文献   

19.
Physostigmine (PHY) is an anticholinergic drug used in the treatment of neuromuscular disorders and organophosphate poisoning. We described a sensitive, accurate, and reproducible method for PHY determination in biological materials. The method utilized a liquid/liquid, ion pair extraction, normal phase HPLC separation, and fluorometric quantitation at 240 nm excitation and 360 nm emission wavelength. We used neostigmine as a stabilizing agent to protect PHY from degradation and dimethylphysostigmine as an internal standard. The peak-height ratio vs concentration was linear over a working range from 0.50 to 25.0 ng/ml of PHY in plasma. Sensitivity of the method was 100 pg/ml of plasma which was the limit of quantitative detection under the experimental conditions used. Precision of the method was evaluated using plasma spiked with two concentrations of PHY: 1.0 and 10.0 ng/ml. Intra-day coefficient of variation (CV) ranged from 3.8 to 5.3%, and inter-day CV ranged from 1.8 to 3.6% for the two levels. The average recovery was 92%. We applied the method to examine the stability of PHY in plasma stored at -15 and -80 degrees C. The data indicated that PHY can be stored at either temperature for 9 weeks without undergoing significant alterations.  相似文献   

20.
An improved method for the determination of catecholamines in biological fluids, by reversed-phase high-performance liquid chromatography (HPLC) with fluorimetric detection is presented. The pH titration previously employed in the alumina extraction was abandoned in favour of the use of a molar excess of pH 8.5 Tris—HCl buffer. A novel lyophilisation step serves to concentrate the catechols and by reconstituting in mobile phase, chromatography disturbances are minimised. The addition of 2 mM octanesulphonic acid to a citrate—phosphate mobile phase at pH 6.0 gave optimal resolution and sensitivity.That HPLC separation can improve the specificity of the trihydroxyindole reaction, to the extent of providing a reliable analytical method, has been demonstrated and validated by the technique of HPLC with electrochemical detection. A correlation coefficient of 0.98 was obtained between the two techniques as applied to the measurement of urinary catecholamines. The HPLC—fluorimetric method was sensitive enough to measure 0.1 ng/ml of noradrenaline or adrenaline at a signal-to-noise ratio of 2.0. Application of the method to the quantitative determination of catecholamines in human urine, plasma and rat brain homogenates is demonstrated.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号