首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The complex mechanical properties of skin have been the subject of much study in recent years. Several experimental methods developed to measure the mechanical properties of skin in vivo, such as suction or torsion, are unable to measure skin’s anisotropic characteristics. An experiment characterising the mechanical properties of in vivo human skin using a novel force-sensitive micro-robot is presented. The micro-robot applied in-plane deformations to the anterior forearm and the posterior upper arm. The behaviour of the skin in each area is highly nonlinear, anisotropic, and viscoelastic. The response of the upper arm skin is very dependent on the orientation of the arm. A finite element model consisting of an Ogden strain energy function and quasi-linear viscoelasticity was developed to simulate the experiments. An orthogonal initial stress field, representing the in vivo skin tension, was used as an additional model parameter. The model simulated the experiments accurately with an error-of-fit of 17.5% for the anterior lower forearm area, 6.5% for the anterior upper forearm and 9.3% for the posterior upper arm. The maximum in vivo tension in each area determined by the model was 6.2 Nm−1 in the anterior lower forearm, 11.4 Nm−1 in anterior upper forearm and 5.6 Nm−1 in the posterior upper arm. The results also show that a finite element model with a neo-Hookean strain energy function cannot simulate the experiments with the same accuracy.  相似文献   

2.
An experimental technique was developed to determine the finite strain field in heterogeneous, diseased human aortic cross sections at physiologic pressures in vitro. Also, the distributions within the cross sections of four histologic features (disease-free zones, lipid accumulations, fibrous intimal tissue, and regions of calcification) were quantified using light microscopic morphometry. A model incorporating heterogeneous, plane stress finite elements coupled the experimental and histologic data. Tissue constituent mechanical properties were determined through an optimization strategy, and the distributions of stress and strain energy in the diseased vascular wall were calculated. Results show that the constituents of atherosclerotic lesions exhibit large differences in their bilinear mechanical properties. The distributions of stress and strain energy in the diseased vascular wall are strongly influenced by both lesion structure and composition. These results suggest that accounting for heterogeneities in the mechanical analysis of atherosclerotic arterial tissue is critical to establishing links between lesion morphology and the susceptibility of plaque to mechanical disruption in vivo.  相似文献   

3.
A finite element method to simulate the formation of an interconnected trabectular bone microstructure oriented with respect to applied in vivo mechanical forces is introduced and quantitatively compared to experimental data from a hydraulic bone chamber implant model. Randomly located 45 microm mineralized nodules were used as the initial condition for the model simulations to represent an early stage of intramembranous bone formation. Boundary conditions were applied consistent with the mechanical environment provided by the in vivo bone chamber model. A two-dimensional repair simulation algorithim that incorporated strain energy density (SED), SED gradient, principal strain, or principal strain gradient as the local objective criterion was utilized to simulate the formation of an oriented trabecular bone microstructure. The simulation solutions were convergent, unique, and relatively insensitive to the assumed initial distribution of mineralized nodules. Model predictions of trabecular bone morphology and anisotropy were quantitatively compared to experimental results. All simulations produced structures that qualitatively resembled oriented trabecular bone. However only simulations utilizing a gradient objective criterion yielded results quantitatively similar to in vivo observations. This simulation approach coupled with an experimental model that delivers controlled in vivo mechanical stimuli can be utilized to study the relationship between physical factors and microstructural adaptation during bone repair.  相似文献   

4.
Three-dimensional (3-D) echocardiography allows the generation of anatomically correct and time-resolved geometric mitral valve (MV) models. However, as imaged in vivo, the MV assumes its systolic geometric configuration only when loaded. Customarily, finite element analysis (FEA) is used to predict material stress and strain fields rendered by applying a load on an initially unloaded model. Therefore, this study endeavors to provide a framework for the application of in vivo MV geometry and FEA to MV physiology, pathophysiology, and surgical repair. We hypothesize that in vivo MV geometry can be reasonably used as a surrogate for the unloaded valve in computational (FEA) simulations, yielding reasonable and meaningful stress and strain magnitudes and distributions. Three experiments were undertaken to demonstrate that the MV leaflets are relatively nondeformed during systolic loading: 1) leaflet strain in vivo was measured using sonomicrometry in an ovine model, 2) hybrid models of normal human MVs as constructed using transesophageal real-time 3-D echocardiography (rt-3DE) were repeatedly loaded using FEA, and 3) serial rt-3DE images of normal human MVs were used to construct models at end diastole and end isovolumic contraction to detect any deformation during isovolumic contraction. The average linear strain associated with isovolumic contraction was 0.02 ± 0.01, measured in vivo with sonomicrometry. Repeated loading of the hybrid normal human MV demonstrated little change in stress or geometry: peak von Mises stress changed by <4% at all locations on the anterior and posterior leaflets. Finally, the in vivo human MV deformed minimally during isovolumic contraction, as measured by the mean absolute difference calculated over the surfaces of both leaflets between serial MV models: 0.53 ± 0.19 mm. FEA modeling of MV models derived from in vivo high-resolution truly 3-D imaging is reasonable and useful for stress prediction in MV pathologies and repairs.  相似文献   

5.
On modelling nonlinear viscoelastic effects in ligaments   总被引:2,自引:0,他引:2  
  相似文献   

6.
A model for axial plant growth is formulated based on conservation of energy. The model derivation assumes that a strain energy function exists to describe the dissipation of potential energy associated with water uptake, mechanical deformation, and biosynthesis during growth. The derivation does not, however, make any further assumption on the mathematical form of this constitutive relation. The model is employed to investigate possible forms of the strain energy function as applied to steady root growth. Solutions of the nonlinear partial differential equations governing growth are given for cases when the third derivative of the strain energy function is >, <, or =0. These three cases encompass a multitude of mathematical forms of the strain energy function. The resulting solutions are compared with the realization of steady axial root growth. The results of this analysis indicate that a quadratic form of the strain energy function best described steady growth. This conclusion is consistent with previous assumptions on the form of constitutive relations for growth, and allows further interpretation on the water relations, mechanical, and biosynthetic energies associated with plant growth.Research support provided by state and federal funds appropriated to the OSU/OARDC. Journal article no. 12–88  相似文献   

7.
A recent report suggests that differences in aerobic capacity exist between concentric and eccentric muscle action in human muscle (T. W. Ryschon, M. D. Fowler, R. E. Wysong, A. R. Anthony, and R. S. Balaban. J. Appl. Physiol. 83: 867-874, 1997). This study compared oxidative response, in the form of phosphocreatine (PCr) resynthesis rates, with matched levels of metabolic strain (i.e., changes in ADP concentration or the free energy of ATP hydrolysis) in tibialis anterior muscle exercised with either muscle action in vivo (n = 7 subjects). Exercise was controlled and metabolic strain measured by a dynamometer and (31)P-magnetic resonance spectroscopy, respectively. Metabolic strain was varied to bring cytosolic ADP concentration up to 55 microM or decrease the free energy of ATP hydrolysis to -55 kJ/mol with no change in cytoplasmic pH. PCr resynthesis rates after exercise ranged from 31.9 to 462.5 and from 21.4 to 405.4 micromol PCr/s for concentric and eccentric action, respectively. PCr resynthesis rates as a function of metabolic strain were not significantly different between muscle actions (P > 0.40), suggesting that oxidative capacity is dependent on metabolic strain, not muscle action. Pooled data were found to more closely conform to previous biochemical measurements when a term for increasing oxidative capacity with metabolic strain was added to models of respiratory control.  相似文献   

8.
Bone strain is the governing stimuli for the remodeling process necessary in the maintenance of bone's structure and mechanical strength. Strain gages are the gold standard and workhorses of human bone experimental strain analysis in vivo. The objective of this systematic literature review is to provide an overview for direct in vivo human bone strain measurement studies and place the strain results within context of current theories of bone remodeling (i.e. mechanostat theory). We employed a standardized search strategy without imposing any time restriction to find English language studies indexed in PubMed and Web of Science databases that measured human bone strain in vivo. Twenty-four studies met our final inclusion criteria. Seven human bones were subjected to strain measurements in vivo including medial tibia, second metatarsal, calcaneus, proximal femur, distal radius, lamina of vertebra and dental alveolar. Peak strain magnitude recorded was 9096 με on the medial tibia during basketball rebounding and the peak strain rate magnitude was -85,500 με/s recorded at the distal radius during forward fall from standing, landing on extended hands. The tibia was the most exposed site for in vivo strain measurements due to accessibility and being a common pathologic site of stress fracture in the lower extremity. This systematic review revealed that most of the strains measured in vivo in different bones were generally within the physiological loading zone defined by the mechanostat theory, which implies stimulation of functional adaptation necessary to maintain bone mechanical integrity.  相似文献   

9.
A strain energy function for finite deformations is developed that has the capability to describe the nonlinear, anisotropic, and asymmetric mechanical response that is typical of articular cartilage. In particular, the bimodular feature is employed by including strain energy terms that are only mechanically active when the corresponding fiber directions are in tension. Furthermore, the strain energy function is a polyconvex function of the deformation gradient tensor so that it meets material stability criteria. A novel feature of the model is the use of bimodular and polyconvex "strong interaction terms" for the strain invariants of orthotropic materials. Several regression analyses are performed using a hypothetical experimental dataset that captures the anisotropic and asymmetric behavior of articular cartilage. The results suggest that the main advantage of a model employing the strong interaction terms is to provide the capability for modeling anisotropic and asymmetric Poisson's ratios, as well as axial stress-axial strain responses, in tension and compression for finite deformations.  相似文献   

10.
High-velocity (up to 25 m/s) impact tests were performed on pig kidneys to characterize failure behavior at deformation rates associated with traumatic injury. Cylindrical tissue samples (n = 45) and whole perfused organs (n = 34) were impacted using both falling weights and a high-velocity pneumatic projectile impactor. Impact energy was incrementally increased until visible rupture occurred. The strain energy density failure threshold fell between 25 and 60 kJ/m3 for excised porcine tissue samples, and between 15 and 30 kJ/m3 for whole, perfused organs. The relationship between localized failure in whole organ impacts and tissue level failure thresholds observed in cylindrical tissue samples was explored using a detailed finite element model of the human kidney. The model showed good correlation between experimentally observed injury patterns and predicted strain energy density distributions within the renal parenchyma. Finally, to facilitate interpretation of the porcine renal impact results with regard to human trauma, quasi-static compression test results of freshly excised human kidney cortex samples (n = 30) were compared against similar tests on pig kidneys. Human tissues failed at Lagrange strain levels similar to porcine tissue (63+/-6.3%), but at 52% lower Lagrange stress (116+/-28 kPa), and 35% lower strain energy density (17.1+/-4.4 kJ/m3). Thus conservative interpretation of porcine test results is recommended.  相似文献   

11.
Distortion data for dog lungs obtained experimentally by Hoppin et al. (1975) are used to arrive at a general mathematical model (strain energy function) which describes finite deformation of lung parenchyma. The strain energy function is correlated with average alveolus model proposed by Frankus and Lee (1974). The latter predicts parenchyma distortion properties from uniformly ventilated pressure-volume data only.  相似文献   

12.
Nonlinear Anisotropic Elastic Properties of the Canine Aorta   总被引:2,自引:0,他引:2       下载免费PDF全文
A nonlinear theory of large elastic deformations of the aortic tissue has been developed. The wall tissue has been considered to be incompressible and curvilinearly orthotropic. The strain energy density function for the tissue is expressed as a polynomial in the circumferential and longitudinal Green-St. Venant strains. Limiting application to states of strains wherein the geometric axes are the principal axes and truncating the energy expression to include terms with highest degrees 2, 3, and 4, three expressions with 3, 7, and 12 constitutive constants are obtained. Results of application of these expressions to data from three series of in vitro and in vivo experiments involving 31 dogs have been presented. Whereas all the three expressions are found to be applicable to various degrees, the third-degree expression for the strain energy density function with seven constitutive constants is particularly recommended for general use.  相似文献   

13.
Accurate tissue stress predictions for the annulus fibrosus are essential for understanding the factors that cause or contribute to disc degeneration and mechanical failure. Current computational models used to predict in vivo disc stresses utilize material laws for annular tissue that are not rigorously validated against experimental data. Consequently, predictions of disc stress resulting from physical activities may be inaccurate and therefore unreliable as a basis for defining mechanical-biologic injury criteria. To address this need we present a model for the annulus as an isotropic ground substance reinforced with two families of collagen fibers, and an approach for determining the material constants by simultaneous consideration of multiple experimental data sets. Two strain energy functions for the annulus are proposed and used in the theory to derive the constitutive equations relating the stress to pure stretch deformations. These equations are applied to four distinct experimental protocols and the material constants are determined from a simultaneous, nonlinear regression analysis. Good agreement between theory and experiment is achieved when the invariants are included within multiple, separate exponentials in the strain energy function.  相似文献   

14.
The purpose of this paper is to investigate the theoretical basis for the pressure-distension behavior of the urinary bladder. A finite strain theory is developed for hollow spherical structures and it is shown that the Treloar model is a good prototype only for rubber balloons. The pressure-extension ratio relationship is inverted to lead a general form of strain energy function, and fitted by an empirical relation involving one exponential. The following form of strain energy function is derived: W(lambda, lambda, lambda -2) = C1 (P(1), a) + P(1)C2 (a, lambda)ea(lambda -1). Where C1(P(1), a) is a constant (N m-2), P(1) is the initial pressure, a is the rate of pressure increase and C2 (a, lambda) a third degree polynomial relation. P(1) and a are experimentally determined through volumetric pressure-distension data. It is verified that this type of energy function is also valid for uniaxial loading experiments by testing strips coming from the same bladder for which P(1) and a were computed. There is a good agreement between the experimental points and the theoretical stress-strain relation. Finally, the strain energy function is plotted as a function of the first strain invariant and appears to be of an exponential nature.  相似文献   

15.
We expressed recombinant human methionine aminopeptidase type 1 (MAP or MetAP) in a map1 null yeast strain to determine the extent of functional complementation between the two proteins. The human MetAP1 protein fully rescued the slow growth phenotype associated with deletion of yeast MetAP1, suggesting that the yeast and human MetAP1 proteins may have similar roles in vivo. Expression of human MetAP1 in yeast has significance in understanding the function of the human protein, studying its in vivo substrate specificity, and developing specific anti-fungal drugs to target yeast MetAP1.  相似文献   

16.
Iron-uptake mutants of Neisseria gonorrhoeae strain 340 were obtained following treatment with streptonigrin, and one such mutant (Fud14) was characterized. N. gonorrhoeae strain Fud14 was unable to grow with human transferrin or haemoglobin as the sole source of iron, but grew normally with heat-inactivated normal human serum or haemin. Internalization of 55Fe from transferrin by strain Fud14 was only 25% of the parent level. Strain Fud14 (less than or equal to 1 x 10(8) c.f.u.) did not grow in subcutaneous chambers implanted in mice, whereas the parent strain was infective at an ID50 of 4.3 x 10(1) c.f.u. Supplementation of chambers with either normal human serum or haemin resulted in the establishment of strain Fud14 in vivo for at least 240 h post-inoculation. Electroporation of Fud14 with wild-type DNA and selection for growth on medium containing human transferrin resulted in a recombinant (Fud15) that was capable of utilizing haemoglobin, and was virulent in mice. These results suggest that a gonococcal strain defective in the ability to utilize in vivo iron sources is not capable of survival in vivo.  相似文献   

17.
To identify the rotavirus protein which mediates attachment to cells in culture, viral reassortants between the simian rotavirus strain RRV and the murine strains EHP and EW or between the simian strain SA-11 and the human strain DS-1 were isolated. These parental strains differ in the requirement for sialic acid to bind and infect cells in culture. Infectivity and binding assays with the parental and reassortant rotaviruses indicate that gene 4 encodes the rotavirus protein which mediates attachment to cells in culture for both sialic acid-dependent and -independent strains. Using ligated intestinal segments of newborn mice and reassortants obtained between the murine strain EW and RRV, we developed an in vivo infectivity assay. In this system, the infectivity of EW was not affected by prior treatment of the enterocytes with neuraminidase, while neuraminidase treatment reduced the infectivity of a reassortant carrying gene 4 from RRV on an EW background more than 80% relative to the controls. Thus, VP4 appears to function as the cell attachment protein in vivo as well as in vitro.  相似文献   

18.
ABSTRACT: BACKGROUND: The human OXR1 gene belongs to a class of genes with conserved functions that protect cells from reactive oxygen species (ROS). The gene was found using a screen of a human cDNA library by its ability to suppress the spontaneous mutator phenotype of an E. coli mutH nth strain. The function of OXR1 is unknown. The human and yeast genes are induced by oxidative stress and targeted to the mitochondria; the yeast gene is required for resistance to hydrogen peroxide. Multiple spliced isoforms are expressed in a variety of human tissues, including brain. RESULTS: In this report, we use a papillation assay that measures spontaneous mutagenesis of an E. coli mutM mutY strain, a host defective for oxidative DNA repair. Papillation frequencies with this strain are dependent upon a G->T transversion in the lacZ gene (a mutation known to occur as a result of oxidative damage) and are suppressed by in vivo expression of human OXR1. N-terminal, C-terminal and internal deletions of the OXR1 gene were constructed and tested for suppression of the mutagenic phenotype of the mutM mutY strain. We find that the TLDc domain, encoded by the final four exons of the OXR1 gene, is not required for papillation suppression in E. coli. Instead, we show that the protein segment encoded by exon 8 of OXR1 is responsible for the suppression of oxidative damage in E. coli. CONCLUSION: The protein segment encoded by OXR1 exon 8 plays an important role in the anti-oxidative function of the human OXR1 protein. This result suggests that the TLDc domain, found in OXR1 exons 12-16 and common in many proteins with nuclear function, has an alternate (undefined) role other than oxidative repair.  相似文献   

19.
20.
Baroreceptor mechanisms at the cellular level   总被引:5,自引:0,他引:5  
Nothing is known of transduction mechanisms of baroreceptors in vivo. Not even the site of transduction is known. However, there are mechanotransducer ion channels that provide a useful model system of transduction. In these channels, transduction is accomplished by a strain-dependent increase in the probability of being open. Membrane tension is coupled to the channel by cytoskeletal strands that concentrate the strain energy from a large (approximately equal to 4000 A diameter) area of membrane and thereby provide high sensitivity. The channel is fast and does not inactivate, but viscoelastic coupling to the channel can dramatically alter the transfer function.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号