首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 312 毫秒
1.

Background

High-sensitive real-time PCR assays are routinely used to monitor HIV-1 infected subjects. Inter-assay discrepancies have been described at the low viral load (VL) end, where clinical decisions regarding possible virological rebound are based.

Methods

A retrospective study was performed to analyze frequencies of viral blips after transition to the COBAS Ampliprep/COBAS TaqMan v2.0 HIV-1 assay (Taqman v2.0) in patients with prior undetectable VLs as measured with the Roche Cobas Ampliprep Amplicor HIV-1 Monitor Test, v1.5 (Amplicor) and was evaluated in comparison to a group of patients monitored with the Abbott Real-time HIV-1 assay (Abbott RT) during the same period of time.

Results

85 of 373 patients with VLs below the limit of quantification with Amplicor had VLs >50 copies/mL after transition to the TaqMan v2.0 assay. Among these 74.1% had VLs ranging from 50–499 copies/mL, 22.9% had VLs >500 copies/mL. From 22 patients with initial Taqman v2.0 based VLs exceeding 500 copies/mL, 6 patients had VLs <20 copies/mL after novel VL measurement on a next visit. In our control group with VL quantification using the Abbott RT assay, only 1 patient became detectable and showed a VL of <40 copies/mL after new measurement.

Conclusions

Transition to the Taqman v2.0 assay was accompanied by an increase of quantifiable HIV-1 VLs in patients with long term viral suppression under antiretroviral therapy that might be attributed to technical shortcomings of the Taqman v2.0 assay. A high test variability at the low VL end but also beyond was observed, making meaningful clinical interpretation of viral blips derived from different assays difficult.  相似文献   

2.
Human immunodeficiency virus type 1 (HIV-1) genetic diversity poses a challenge to reliable viral load monitoring. Discrepancies between different testing platforms have been observed, especially for non-clade-B virus. Therefore we compare, in antiretroviral therapy (ART)-naïve South African subjects predominantly infected with HIV-1 clade-C, three commercially available assays: the COBAS AmpliPrep/COBAS TaqMan HIV-1 Test version 2.0 by Roche (CAP/CTM v2.0), the BioMérieux NucliSens Version 2.0 Easy Q/Easy Mag (NucliSens v2.0) and the Roche COBAS Amplicor HIV-1 Monitor Test Version 1.5 (Amplicor v1.5). Strong linear correlation was observed and Bland-Altman analyses showed overall good agreement between the assays with mean viral load differences of 0.078 log cp/ml (NucliSens v2.0 – Amplicor v1.5), 0.260 log cp/ml (CAP/CTM v2.0 – Amplicor v1.5) and 0.164 log cp/ml (CAP/CTM v2.0 – NucliSens v2.0), indicating lower mean viral load results for the Amplicor v1.5 and higher mean readings for the CAP/CTM v2.0. Consistent with observations following previous comparisons of CAP/CTM v2.0 versus Amplicor v1.5, the CAP/CTM v2.0 assay detected low-level viremia (median 65 cp/ml) in more than one-third of those in whom viremia had been undetectable (<20 cp/ml) in assays using the NucliSens platform. These levels of viremia are of uncertain clinical significance but may be of importance in early detection of ART resistance in those on treatment. Overall the three assays showed good comparability of results but with consistent, albeit relatively small, discrepancies for HIV-1 clade-C samples, especially in the low-viremic range that should be taken into account when interpreting viral load data.  相似文献   

3.
BackgroundThe complex epidemic and significant diversity of HIV-1 strains in China pose serious challenges for surveillance and diagnostic assays, vaccine development and clinical management. There is a lack of HIV-1 isolates in current canonical HIV-1 subtype panels that can represent HIV-1 diversity in China; an HIV-1 subtype panel for China is urgently needed.MethodsBlood samples were collected from HIV-1 infected patients participating in the drug-resistance surveillance program in China. The samples were isolated, cultured and stored as neat culture supernatant. The HIV-1 isolates were fully characterized. The panel was used to compare 2 viral load assays and 2 p24 assays as the examples of how this panel could be used.ResultsAn HIV-1 subtype panel for China composed of 30 HIV-1 primary strains of four subtypes (B [including Thai-B], CRF01_AE, CRF07_BC and G) was established. The samples were isolated and cultured to a high-titer (106-109 copies/ml)/high-volume (40ml). The HIV-1 isolates were fully characterized by the final viral load, p24 concentration, gag-pol and envC2V3 sequencing, co-receptor prediction, determination of the four amino acids at the tip of the env V3-loop, glycosylation sites in the V3 loop and the drug-resistance mutations. The comparison of two p24 assays and two viral load assays on the isolates illustrated how this panel may be used for the evaluation of diagnostic assay performance. The Pearson value between p24 assays were 0.938. The viral load results showed excellent concordance and agreement for samples of Thai-B, but lower correlations for samples of CRF01_AE.ConclusionThe current panel of 30 HIV-1 isolates served as a basis for the development of a comprehensive panel of fully characterized viral isolates, which could reflect the current dynamic and complex HIV-1 epidemic in China. This panel will be available to support HIV-1 research, assay evaluation, vaccine and drug development.  相似文献   

4.
5.
6.
The HCV virus is a common human pathogen made of a single stranded RNA genome with 9600nt. This work compared two different commercial methods used for HCV viral load, the bDNA Bayer Versant HCV 3.0 and the RealTime Roche COBAS TaqMan 48 HCV. We compared the reproducibility and linearity of the two methods. Seventy-five plasma samples with genotypes 1 to 4, which represent the population (45% genotype 1; 24% genotype 2; 13% genotype 3; 18% genotype 4) were directly processed with the Versanto method based upon signal amplification; the same samples were first extracted (COBAS Ampliprep - TNAI) and then amplified using RealTime PCR (COBAS TaqMan 48). The results obtained indicate the same performance for both methods if they have genotype 1, but in samples with genotypes 2, 3 and 4 the RealTime PCR Roche method gave an underestimation in respect to the Bayer bDNA assay.  相似文献   

7.
8.
Branched DNA (bDNA) is a signal amplification technology used in clinical and research laboratories to quantitatively detect nucleic acids. An overnight incubation is a significant drawback of highly sensitive bDNA assays. The VERSANT® HIV-1 RNA 3.0 Assay (bDNA) (“Versant Assay”) currently used in clinical laboratories was modified to allow shorter target incubation, enabling the viral load assay to be run in a single day. To dramatically reduce the target incubation from 16–18 h to 2.5 h, composition of only the “Lysis Diluent” solution was modified. Nucleic acid probes in the assay were unchanged. Performance of the modified assay (assay in development; not commercially available) was evaluated and compared to the Versant Assay. Dilution series replicates (>950 results) were used to demonstrate that analytical sensitivity, linearity, accuracy, and precision for the shorter modified assay are comparable to the Versant Assay. HIV RNA-positive clinical specimens (n = 135) showed no significant difference in quantification between the modified assay and the Versant Assay. Equivalent relative quantification of samples of eight genotypes was demonstrated for the two assays. Elevated levels of several potentially interfering endogenous substances had no effect on quantification or specificity of the modified assay. The modified assay with drastically improved turnaround time demonstrates the viability of signal-amplifying technology, such as bDNA, as an alternative to the PCR-based assays dominating viral load monitoring in clinical laboratories. Highly sensitive bDNA assays with a single day turnaround may be ideal for laboratories with especially stringent cost, contamination, or reliability requirements.  相似文献   

9.
10.
11.
This study compared two published TaqMan PCR assays targeting different regions of the HIV-1 genome for detection of HIV-1 proviral DNA. The gag specific PCR demonstrated a lower sensitivity than the assay targeting the LTR region. The LTR assay is a highly reproducible and specific technique for HIV-1 proviral DNA detection.  相似文献   

12.
This study evaluated the performance characteristics of the AmpliScreen(TM)Human Immunodeficiency Virus-Type 1 (HIV-1) Test, Version 1.5, a test designed for screening pools composed of samples from individual units of blood or plasma. HIV-1, hepatitis C (HCV) and hepatitis B (HBV) virus particles were simultaneously extracted and concentrated from plasma by a multi-prep sample processing procedure. An HIV-1 Internal Control (IC) RNA was added to each sample to serve as an extraction and amplification control. Processed samples were amplified by RT-PCR using HIV-1-specific complementary primers and detected by hybridization of the amplified products to HIV-1- and IC-specific oligonucleotide probes.The analytical sensitivity of the test (concentration that yields >/=95% positive results in a set of replicate tests) was 25 copies of HIV-1 RNA per mL of pooled plasma. Representative strains from all HIV-1 group M subtypes were reproducibly detected (>95% positive results among 22 replicate tests) at concentrations of 30 to 75 viral particles per ml. The test exhibited excellent specificity; it did not cross-react with a set of 30 viral and five bacterial isolates and yielded negative results on a panel of 500 blood samples from HIV-1 seronegative donors. Samples containing abnormally high levels of haemoglobin, albumin, triglycerides or bilirubin in plasma samples did not interfere with the detection of HIV-1 RNA at a concentration of 100 copies of per ml. The test detected HIV-1 RNA 7-17 days prior to anti-HIV-1 antibody seroconversion for all 10 seroconversion panels tested. A fully automated COBAS AmpliScreen(TM)version of this test is being validated. COBAS AmpliScreen tests for HCV and HBV also incorporate the multi-prep specimen processing method, thereby making it possible to use a single processed specimen to screen for all three viruses.  相似文献   

13.

Background

Human Immunodeficiency Virus Type 1 (HIV-1) viral load testing at regular intervals is an integral component of disease management in Acquired Immunodeficiency Syndrome (AIDS) patients. The need in countries like India is therefore an assay that is not only economical but efficient and highly specific for HIV-1 sub type C virus. This study reports a SYBR Green-based HIV-1 real time PCR assay for viral load testing and is designed for enhanced specificity towards HIV-1 sub type C viruses prevalent in India.

Results

Linear regression of the observed and reference concentration of standards used in this study generated a correlation coefficient of 0.998 (p < 0.001). Lower limit of detection of the test protocol was 50 copies/ml of plasma. The assay demonstrated 100% specificity when tested with negative control sera. The Spearman coefficient of the reported assay with an US-FDA approved, Taqman probe-based commercial kit was found to be 0.997. No significant difference in viral load was detected when the SYBR Green based assay was used to test infected plasma stored at -20°C and room temperature for 7 days respectively (Wilcoxon signed rank test, p = 0.105). In a comparative study on 90 pretested HIV-1 positive samples with viral loads ranging from 5,000–25,000 HIV-1 RNA copies/ml and between two commercial assays it was found that the later failed to amplify in 13.33% and 10% samples respectively while in 7.77% and 4.44% samples the copy number values were reduced by >0.5 log value, a figure that is considered clinically significant by physicians.

Conclusion

The HIV-1 viral load assay reported in this study was found to be robust, reliable, economical and effective in resource limited settings such as those existing in India. PCR probes specially designed from HIV-1 Subtype C-specific nucleotide sequences originating from India imparted specificity towards such isolates and demonstrated superior results when compared to two similar commercial assays widely used in India.  相似文献   

14.
15.
Nearly full-length genome sequencing of HIV-1 using peripheral blood mononuclear cells (PBMC) DNA as a template for PCR is now a relatively routine laboratory procedure. However, this has not been the case when using virion RNA as the template and this has made full genome analysis of circulating viruses difficult. Therefore, a well-developed procedure for sequencing of full-length HIV-1 RNA directly from plasma was needed. Plasma from U.S. donors representing a range of viral loads (VL) was used to develop the assay. RNA was extracted from plasma and reverse-transcribed. Two or three overlapping regions were PCR amplified to cover the entire viral genome and sequenced for verification. The success of the procedure was sensitive to VL but was routinely successful for VL greater than 10(5) and the rate declined in proportion to the VL. While the two-amplicon strategy had an advantage of increasing the possibility of amplifying a single species of HIV-1, the three-amplicon strategy was more successful in amplifying samples with low viral loads. This protocol provides a useful tool for molecular analysis to understand the HIV epidemic and pathogenesis, as well as diagnosis, therapy and future vaccine strategies.  相似文献   

16.
Neutralizing antibody responses against heterologous isolates in human immunodeficiency virus type 1 (HIV-1) and HIV-2 infections were compared, and their relationships with established clinical markers of progression were examined. Neutralizing responses against 7 heterologous primary isolates and 1 laboratory strain were compared between 32 untreated HIV-1-infected subjects and 35 untreated HIV-2-infected subjects using a pseudotyped reporter virus assay. The breadth of the neutralizing response, defined as the proportion of panel viruses positively neutralized by patient plasma, was significantly greater among HIV-2-infected subjects than among HIV-1-infected subjects. Notably, for fully one-third of HIV-2 subjects, all viruses were effectively neutralized in our panel. Magnitudes of responses, defined as reciprocal 50% inhibitory concentration (IC(50)) titers for positive reactions, were significantly greater among HIV-1-infected subjects than among HIV-2-infected subjects. When plasma samples from HIV-1 patients were tested for cross-neutralization of HIV-2 and vice versa, we found that these intertype responses are very rare and their prevalences comparable in both HIV-1 and HIV-2 infection. The significantly higher magnitude of heterologous responses for HIV-1 compared to HIV-2 prompted us to examine associations with viremia, which is known to be significantly higher in HIV-1 infection. Importantly, there was a significant positive correlation between the IC(50) titer and viral load within both the HIV-1 and HIV-2 groups, suggesting heterologous antibodies may be driven by viral replication. We conclude that HIV-2 infection is characterized by a broad, low-magnitude intratype neutralization response, while HIV-1 is characterized by a narrower but higher-magnitude intratype response and that a significant positive association between the IC(50) titer and viremia is common to both HIV-1 and HIV-2 infections.  相似文献   

17.

Background

The use of in vitro models to unravel the phenotypic characteristics of circulating viral variants is key to understanding HIV-1 pathogenesis but limited by the availability of primary viral isolates from biological samples. However, overall in vivo genetic variability of HIV-1 within a subject may not be reflected in the viable viral population obtained after isolation. Although several studies have tried to determine whether viral populations expanded in vitro are representative of in vivo findings, the answer remains unclear due to the reduced number of clonal sequences analyzed or samples compared. In order to overcome previous experimental limitations, here we applied Deep Pyrosequencing (DPS) technology in combination with phenotypic experiments to analyze and compare with unprecedented detail the composition of viral isolates and in vivo quasispecies.

Methodology/Principal Findings

We amplified by DPS HIV-1 genomic regions covering gag, protease, integrase and env-V3 to characterize paired isolates from plasma and peripheral blood mononuclear cells and compare them with total plasma viral RNA in four recently HIV-1 infected subjects. Our study demonstrated the presence of unique haplotypes scattered between sample types with conservation of major variants. In addition, no differences in intra- and inter-population encoded protein variability were found between the different types of isolates or when these were compared to plasma viral RNA within subjects. Additionally, in vitro experiments demonstrated phenotypic similarities in terms of replicative capacity and co-receptor usage between viral isolates and plasma viral RNA.

Conclusion

This study is the first in-depth comparison and characterization of viral isolates from different sources and plasma circulating quasispecies using DPS in recently HIV-1 infected subjects. Our data supports the use of primary isolates regardless of their plasma or cellular origin to define genetic variability and biological traits of circulating HIV-1 quasispecies.  相似文献   

18.
目的:探讨核酸定量检测在HIV-1感染实验室诊断中的应用。方法:选取145例第四代抗原/抗体联合诊断筛查试验为阳性反应的血浆样本,分别用Western印迹和HIV-1核酸定量方法进行检测,综合对比分析2种方法检测结果。结果:Western印迹检出阳性样本120例,不确定样本17例,阴性样本8例;HIV-1核酸定量试验检出结果大于检测限样本131例,其中包括12例Western印迹不确定样本、2例Western印迹阴性样本;有3例Western印迹阳性样本用HIV-1核酸定量检测试验未能检出。结论:核酸定量检测试验对于HIV-1感染阳性样本是一种有效的实验室诊断方法;对HIV-1核酸定量检测结果为"TND"的样本,建议加做Western印迹或结合其他补充试验结果进行综合诊断。  相似文献   

19.

Background

Plasma HIV-1 RNA monitoring is one of the standard tests for the management of HIV-1 infection. While HIV-1 RNA can be quantified using several commercial tests, no test has been commercialized for HIV-2 RNA quantification. We studied the relationship between plasma HIV-2 viral load (VL) and CD4 count in West African patients who were either receiving antiretroviral therapy (ART) or treatment-naïve.

Method

A cross sectional survey was conducted among HIV-2-infected individuals followed in three countries in West Africa from March to December 2012. All HIV-2 infected-patients who attended one of the participating clinics were proposed a plasma HIV-2 viral load measurement. HIV-2 RNA was quantified using the new ultrasensitive in-house real-time PCR assay with a detection threshold of 10 copies/ mL (cps/mL).

Results

A total of 351 HIV-2-infected individuals participated in this study, of whom 131 (37.3%) were treatment naïve and 220 (62.7%) had initiated ART. Among treatment-naïve patients, 60 (46.5%) had undetectable plasma HIV-2 viral load (<10 cps/mL), it was detectable between 10-100 cps/mL in 35.8%, between 100-1000 cps/mL in 11.7% and >1000 cps/mL in 6.0% of the patients. Most of the treatment-naïve patients (70.2%) had CD4-T cell count ≥500 cells/mm3 and 43 (46.7%) of these patients had a detectable VL (≥10 cps/mL). Among the 220 patients receiving ART, the median CD4-T cell count rose from 231 to 393 cells/mm3 (IQR [259-561]) after a median follow-up duration of 38 months and 145 (66.0%) patients had CD4-T cell count ≤ 500 cells/mm3 with a median viral load of 10 cps/mL (IQR [10-33]). Seventy five (34.0%) patients had CD4-T cell count ≥ 500 cells/mm3, among them 14 (18.7%) had a VL between 10-100 cps/mL and 2 (2.6%) had VL >100 cps/mL.

Conclusion

This study suggests that the combination of CD4-T cell count and ultrasensitive HIV-2 viral load quantification with a threshold of 10 cps/mL, could improve ART initiation among treatment naïve HIV-2-infected patients and the monitoring of ART response among patients receiving treatment.  相似文献   

20.
An assay for the neutralization of human immunodeficiency virus type 1 (HIV-1) is described in which the reduction in infectious titer of HIV-1 after preincubation at 37 degrees C with antibody-positive serum is the measure of neutralization. The assay format and its controls allow several experimental manipulations that, taken together, indicate an effect of antibody on HIV-1 infectivity that occurs before or independently of HIV-1 attachment. The direct inactivation of HIV-1 infectivity by antibody is irreversible and temperature dependent, requires a bivalent antibody directed against accessible envelope determinants, and does not require a heat-labile or (Ca2+)- or (Mg2+)-dependent cofactor. The mechanism of inactivation cannot be explained by agglutination of virus, nor is it associated with disruption or dissociation of envelope protein from virions. Rather, the antibody is likely to perturb some metastable property of the envelope that is required for entry. Laboratory-adapted HIV-1 isolates were more sensitive to the inactivating effects of sera than were primary patient isolates. The latter were particularly resistant to inactivation by contemporary autologous sera, a feature not explained by blocking antibodies. Additional studies showed a weak relationship between disease course and serum inactivation of the reference LAI laboratory strain of HIV-1. Heteroduplex analysis and autologous inactivation assays of sequential specimens from individual patients indicate that over time, the viral quasispecies that emerge and dominate are resistant to the inactivating effects of earlier sera.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏