首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.

Purpose

To explore ocular changes in healthy people after exercise.

Methods

Twenty five volunteers underwent exercise for 15 minutes on a treadmill. Measurements of choroidal thickness, intraocular pressure (IOP), ocular biometry, and blood pressure were taken before and after exercise. Enhanced Depth Imaging optical coherence tomography (EDI-OCT) was used to measure choroidal thickness at the fovea. Intraocular pressure (IOP) was measured by Goldmann applanation tonometry. Ocular biometric measures were collected using A scan ultrasound. Blood pressure was measured concurrently with the acquisition of the scans.

Results

Twenty five volunteers (25 eyes) with a mean age of 25.44±3.25 years were measured. There was a significant increase in systolic and diastolic pressure after exercise (P<0.05). The IOP showed a significant decrease after exercise (P<0.05). However there was no significant difference in the mean choroidal thickness, ocular axial length, anterior chamber depth, lens thickness, or vitreous length before and after exercise measurements (P>0.05).

Conclusion

There was a significant decrease in IOP from exercise without a change in choroidal thickness and ocular biometric measures. IOP and choroidal thickness were not correlated, suggesting that the IOP decrease from exercise is not due to changes in choridal thickness.  相似文献   

2.

Background

To determine the mean values for central corneal thickness (CCT) and intraocular pressure (IOP) and the relationship between these values, in healthy Malay children to serve as reference values in diagnosis and treatment.

Design

A cross-sectional study.

Methodology/Principal Findings

One hundred and eight eyes (54 subjects) of Malay children without diagnosis of ocular abnormality or disease meeting our inclusion and exclusion criteria were selected. The CCT and IOP were measured by specular microscopy and non-contact air-puff tonometry respectively, for analysis and comparison with the values obtained in previous studies. Mean CCT and IOP was found to be 530.87±30.79 µm and 15.65±3.05 mm Hg respectively. CCT was found not to vary with age. A positive relationship was found between CCT and IOP; specifically, with every 100-µm increase in CCT, IOP increased by 3.5 mm Hg.

Conclusions/Significance

CCT and IOP are strongly related in healthy Malay children aged 8 to 16. The mean CCT of Malay children is lower than that of majority children of other ethnic groups, supporting the existence of CCT variation among different populations and that ethnicity should be a key consideration when applying CCT data to the general pediatric population.  相似文献   

3.

Aims

To investigate the feasibility and to compare three devices measuring intraocular pressure (IOP) in mucopolysaccharidosis patients (MPS): iCare rebound tonometer (RT), Perkins applanation tonometer (PAT) and ocular response analyzer (ORA)

Methods

MPS patients who underwent at least two examinations out of: RT, PAT and ORA at the same visit were identified and retrospectively analyzed in this study.

Results

17 patients fulfilled the inclusion criterion. In all 17 patients IOP measurements were performed with RT (34 eyes) and ORA (33 eyes), while PAT measurement was possible in only 12 (24 eyes) patients. The RT, corneal-compensated intraocular pressure (IOPcc) and Goldmann-correlated intraocular pressure (IOPg) differed relevantly from IOP assessed with PAT. Corneal clouding in MPS patients correlated positively with PAT, RT and IOPg (r = 0.3, 0.5, and 0.5 respectively), but not with IOPcc (r = 0.07). The MPS-related corneal clouding correlated positively with biomechanical corneal parameters assessed with ORA: corneal hysteresis (r = 0.77) and corneal resistance factor (r = 0.77) either.

Conclusions

RT and ORA measurements were tolerated better than applanation tonometry in MPS patients. IOP measurements assessed with RT and ORA differed relevantly from PAT. Corneal-compensated IOP assessed with ORA seems to be less affected by the MPS-related corneal clouding than applanation or rebound tonometry. RT and ORA measurements should be preferred for IOP assessment in patients with MPS.  相似文献   

4.

Purpose

To study age-related changes of intraocular pressure (IOP) and assess the cohort effect in both cross-sectional and longitudinal settings among elderly Chinese adults.

Methods

Participants were enrolled from the Lingtou Eye Cohort Study with Chinese government officials aged 40 years and older at baseline and received physical check-up and ocular examinations from 2010 to 2012. IOP was measured using a non-contact tonometer according to standardized protocols, as well as systolic blood pressure (SBP), diastolic blood pressure (DBP) and body mass index (BMI). Participants who had attended IOP measurements in both 2010 and 2012 were included in this study. Cross-sectional association of IOP with age was assessed using multivariate liner regression analyses and based on the data of 2010. Longitudinal changes in IOP were assessed by paired t-test.

Results

A total of 3372 subjects were enrolled in the current analysis (2010 mean [SD] age, 61.9 [7.1] years; 60.2% men). The mean IOP in 2010 was 15.4±2.3 mmHg for women and 15.2±2.3 mmHg for men with an intersex difference (P = 0.029). Cross-sectional analysis showed that IOP was negatively associated with age (P = 0.003, β = -0.033 for women and P<0.001, β = -0.061 for men) adjusted for baseline SBP, DBP and BMI. Paired t-test suggested that IOP was higher in the year 2012 than 2010 in women (P = 0.006) but did not change significantly in men within 2 years (P = 0.345). In addition, the 2-year changes of IOP were not associated with age adjusted for baseline IOP in 2010 (P = 0.249).

Conclusion

Cross-sectional data suggests that IOP is lower in people with older age. Longitudinal data does not support such findings and thus the identified decreasing pattern with age in cross-sectional analysis is likely caused by cohort effects.  相似文献   

5.

Objective

To investigate the 5-year incidence and progression rate of primary open-angle glaucoma (POAG) in a health-center-based Korean population.

Methods

The study population comprised 5,021 subjects who participated in standardized health screening (including non-contact tonometry and fundus photography) at the Gangnam Healthcare Center during the period from January 2005 to December 2006 and again from January 2010 to December 2011. Among these subjects, 948 (18.9%) with findings suggestive of glaucoma were subjected to a comprehensive glaucoma evaluation, which included applanation tonometry and standard automated perimetry. Based on the results, the subjects were diagnosed as POAG suspect or definite POAG.

Results

The 5-year incidences of POAG suspect and definite POAG were 0.84% (42 subjects) and 0.72% (36 subjects), respectively. The rate of progression from POAG suspect to definite POAG was 4.75% per year. In subjects with a baseline intraocular pressure (IOP) >21 mmHg, the incidence of POAG suspect or definite POAG was significantly higher than in those with a baseline IOP≤21 mmHg (32% vs. 1.05%; P<0.001). A multivariate analysis showed that the progression from POAG suspect to definite POAG was significantly associated with older age (odds ratio [OR], 1.07; 95% confidence interval [CI], 1.03–1.10), higher baseline IOP (OR, 1.10; 95% CI, 1.01–1.24), higher body mass index (BMI) (OR, 1.15; 95% CI, 1.03–1.31), higher education level (OR, 1.57; 95% CI, 1.05–2.17), and higher hematocrit level (OR, 1.22; 95% CI, 1.08–1.43).

Conclusions

In the health-center-based Korean population, the 5-year incidence of POAG was 0.72%, and the rate of progression from POAG suspect to definite POAG was 4.75% per year. This study identified old age, high baseline IOP, high BMI, high level of education, and high hematocrit level as significant risk factors for incident POAG.  相似文献   

6.

Purpose

To investigate the changes of intraocular pressure (IOP) induced by 3-diopter (3 D) accommodation in progressing myopes, stable myopes and emmetropes.

Design

Cross-sectional study.

Participants

318 subjects including 270 myopes and 48 emmetropes.

Methods

195 progressing myopes, 75 stable myopes and 48 emmetropes participated in this study. All subjects had their IOP measured using iCare rebound tonometer while accommodative stimuli of 0 D and 3 D were presented.

Main Outcome Measures

IOP values without accommodation and with 3 D accommodation were measured in all subjects. Baseline IOPs and IOP changes were compared within and between groups.

Results

There was no significant difference in IOPs between progressing myopes, stable myopes and emmetropes when no accommodation was induced (17.47±3.46, 16.62±2.98 and 16.80±3.62 respectively, p>0.05). IOP experienced an insignificantly slight decrease after 3 D accommodation in three groups (mean change -0.19±2.16, -0.03±1.68 and -0.39±2.65 respectively, p>0.05). Subgroup analysis showed in progressing myopic group, IOP of children (<18 years old) declined with accommodation while IOP of adults (≥18 years) increased, and the difference was statistically significant (p = 0.008). However, after excluding the age factor, accommodation induced IOP changes of high progressing myopes (≤-6 D), low, moderate and non-myopes (>-6 D) was not significantly different after Bonferroni correction (p = 0.838).

Conclusions

Although no difference was detected between the baseline IOPs and accommodation induced IOP changes in progressing myopes, stable myopes and emmetropes, this study found accommodation could cause transient IOP elevation in adult progressing myopes.  相似文献   

7.

Purpose

To assess the short-term day-to-day reproducibility of 24-hour intraocular pressure (IOP) curves in various respects in untreated primary open-angle glaucoma (POAG) and ocular hypertension (OHT) patients.

Methods

47 subjects with POAG and 34 subjects with OHT underwent IOP measurements every 2 hours in both eyes for consecutive 48 hours by a non-contact tonometer (NCT). IOP values at each time point were recorded. Mean IOP, peak IOP, time difference of peak IOP between two days and IOP fluctuation were also calculated. Intraclass correlation coefficients (ICCs) and Bland-Altman plots were used to evaluate reproducibility.

Results

ICCs of the entire IOP values for a complete 24-hour curve were 0.577 and 0.561 in POAG and OHT patients, respectively. ICCs of IOP values at different time points ranged from 0.384 (10am) to 0.686 (4am) in POAG patients and from 0.347 (6am) to 0.760 (4am) in OHT patients. ICCs of mean IOP, peak IOP and IOP fluctuation were respectively 0.832, 0.704, 0.367 in POAG patients and 0.867, 0.816 0.633 in OHT patients. Only 37.23% and 35.29% of the peak IOP time points appeared within the time difference of 2 hours in POAG and OHT patients, respectively, while 53.19% and 48.53% appeared within 4 hours in POAG and OHT patients, respectively.

Conclusion

A 24-hour IOP curve in a single day is not highly reproducible in short-term and has limited use for evaluating individual IOP condition. Mean IOP and peak IOP for a 24-hour IOP curve are useful parameters in clinical follow-up, while IOP value at a certain time point, IOP fluctuation and peak IOP time point should be interpreted with caution.  相似文献   

8.

Purpose

To investigate whether corneal thickness parameters measured by optical coherence tomography (OCT), such as central corneal thickness (CCT), central corneal stromal thickness (CCST), and central corneal epithelial thickness (CCET), influence the intraocular pressure (IOP) difference measured by Goldmann applanation tonometry (GAT) and non-contact tonometry (NCT).

Methods

In total, 50 eyes from 50 subjects without glaucomatous defects were included in this retrospective, cross-sectional study. We measured IOP using GAT and NCT and calculated the difference between the two methods. CCT was measured by a Cirrus HD-OCT device using anterior segment imaging. The basement membrane of the epithelium, which was seen as a high-reflection line in the OCT image, was taken as a reference line to measure CCST and CCET.

Results

The mean IOP measured by GAT and NCT was 16.7 ± 3.0 and 18.1 ± 3.8 mmHg, respectively. The mean IOP difference was 1.5 ± 1.7 mmHg, and the IOP measured by NCT was 8.4% ± 11.3% higher than that measured by GAT. The CCET and CCST were 57.9 ± 5.6 and 501.7 ± 33.8 μm, respectively. CCT showed a positive correlation with both GAT IOP (r = 0.648, P < 0.001) and NCT IOP (r = 0.676, P < 0.001). Although CCST showed a significant correlation with GAT IOP and NCT IOP, CCET did not. The difference between GAT IOP and NCT IOP increased with CCT (r = 0.333, P = 0.018), and CCET was positively correlated with the IOP difference between GAT and NCT (r = 0.435, P = 0.002).

Conclusions

IOP increased with greater CCT, and CCST seemed to have a more important role than CCET. CCET also increased with greater CCT, and this may be a possible explanation for the increasing difference in IOP between GAT and NCT with increasing CCT.  相似文献   

9.

Objective

To study the association between Cruciate Ligament (CL) injury and development of post-traumatic osteoarthritis in the knee in patients treated operatively with CL reconstruction compared with patients treated non-operatively.

Design

Population based cohort study; level of evidence II-2.

Setting

Sweden, 1987–2009.

Participants

All patients aged between 15–60 years being diagnosed and registered with a CL injury in The National Swedish Patient Register between 1987 and 2009.

Main Outcome Measures

Knee osteoarthritis.

Results

A total of 64,614 patients diagnosed with CL injury during 1987 to 2009 in Sweden were included in the study. Seven percent of the patients were diagnosed with knee OA in specialized healthcare during the follow-up (mean 9 years). Stratified analysis by follow-up showed that while those with shorter follow-up had a non-significant difference in risk (0.99, 95%CI 0.90–1.09 for follow-up less than five years compared with the non-operated cohort), those with longer follow-up had an increased risk of knee OA after CL reconstruction (HR = 1.42, 95%CI 1.27–1.58 for follow-up more than ten years compared with non-operated cohort). The risk to develop OA was not affected by sex.

Conclusion

CL reconstructive surgery does not seem to have a protective effect on long term OA in either men or women.  相似文献   

10.

Purpose

To examine characteristics of ocular hypertensive subjects and potential associations with estimated cerebrospinal fluid pressure (estCSFP).

Methods

The population-based Beijing Eye Study 2011 included 3468 individuals with a mean age of 64.6±9.8 years. Ocular hypertension was defined as intraocular pressure (IOP) >21 mmHg, normal optic nerve head appearance and normal retinal nerve fiber layer thickness. IOP was corrected for its dependence on central corneal thickness (CCT) and corneal curvature radius. Estimated CSFP was calculated as CSFP [mmHg] = 0.44×Body Mass Index [kg/m2]+0.16×Diastolic Blood Pressure [mmHg]−0.18×Age [Years]−1.91. Estimated trans-lamina cribrosa pressure difference (estTLCPD) was IOP–estCSFP.

Results

EstCSFP (10.5±3.6 mmHg versus 9.0±3.7 mmHg; P = 0.003) and estTLCPD (12.0±4.4 mmHg versus 5.4±3.8 mmHg; P<0.001) were higher in the ocular hypertensive group than in the normotensive group. In binary regression analysis, ocular hypertension was associated with increased estCSFP (P = 0.03; odds ratio (OR): 1.08; 95% confidence interval (CI): 1.01, 1.17) after adjusting for prevalence of arterial hypertension (P = 0.07; OR: 1.79; 95%CI: 0.96, 3.34), retinal nerve fiber layer thickness (P = 0.03; OR: 0.97; 95%CI: 0.95, 0.997) and blood glucose concentration (P = 0.006; OR: 1.17; 95%CI: 1.04, 1.30).

Conclusions

Ocular hypertensive subjects (with IOP correction for CCT and corneal curvature) as compared to ocular normotensive subjects had a significantly higher estCSFP in univariate analysis and in multivariate analysis. Despite of a higher estCSFP, estTLCPD was still markedly higher in ocular hypertensive eyes than in ocular normotensive eyes.  相似文献   

11.

Purpose

To further improve in vitro models of the cornea, this study focused on the creation of a three-dimensional, stratified, curved epithelium; and the subsequent characterization and evaluation of its suitability as a model for biocompatibility testing.

Methods

Immortalized human corneal epithelial cells were grown to confluency on curved cellulose filters for seven days, and were then differentiated and stratified using an air-liquid interface for seven days before testing. Varying concentrations of a commercial ophthalmic solution containing benzalkonium chloride (BAK), a known cytotoxic agent, and two relevant ocular surfactants were tested on the model. A whole balafilcon A lens soaked in phosphate buffered saline (BA PBS) was also used to assess biocompatibility and verify the validity of the model. Viability assays as well as flow cytometry were performed on the cells to investigate changes in cell death and integrin expression.

Results

The reconstructed curved corneal epithelium was composed of 3–5 layers of cells. Increasing concentrations of BAK showed dose-dependent decreased cell viability and increased integrin expression and cell death. No significant change in viability was observed in the presence of the surfactants. As expected, the BA PBS combination appeared to be very biocompatible with no adverse change in cell viability or integrin expression.

Conclusions

The stratified, curved, epithelial model proved to be sensitive to distinct changes in cytotoxicity and is suitable for continued assessment for biocompatibility testing of contact lenses. Our results showed that flow cytometry can provide a quantitative measure of the cell response to biomaterials or cytotoxic compounds for both the supernatant and adherent cell populations. As a specifically designed in vitro model of the corneal epithelium, this quantitative model for biocompatibility at the ocular surface may help improve our understanding of cell-material interactions and reduce the use of animal testing.  相似文献   

12.

Objective

Boluses are used in high-energy radiotherapy in order to overcome the skin sparing effect. In practice though, commonly used flat boluses fail to make a perfect contact with the irregular surface of the patient’s skin, resulting in air gaps. Hence, we fabricated a customized bolus using a 3-dimensional (3D) printer and evaluated its feasibility for radiotherapy.

Methods

We designed two kinds of bolus for production on a 3D printer, one of which was the 3D printed flat bolus for the Blue water phantom and the other was a 3D printed customized bolus for the RANDO phantom. The 3D printed flat bolus was fabricated to verify its physical quality. The resulting 3D printed flat bolus was evaluated by assessing dosimetric parameters such as D1.5 cm, D5 cm, and D10 cm. The 3D printed customized bolus was then fabricated, and its quality and clinical feasibility were evaluated by visual inspection and by assessing dosimetric parameters such as Dmax, Dmin, Dmean, D90%, and V90%.

Results

The dosimetric parameters of the resulting 3D printed flat bolus showed that it was a useful dose escalating material, equivalent to a commercially available flat bolus. Analysis of the dosimetric parameters of the 3D printed customized bolus demonstrated that it is provided good dose escalation and good contact with the irregular surface of the RANDO phantom.

Conclusions

A customized bolus produced using a 3D printer could potentially replace commercially available flat boluses.  相似文献   

13.

Background

An opioid peptide neuron/humoral feedback regulation might be involved in changes of intraocular pressure (IOP). The aims of this study are to investigate the effects of arcuate nucleus (ARC) and opioid peptides on intraocular pressure (IOP).

Methods

Fifty-four healthy purebred New Zealand white rabbits (108eyes) were randomly divided into 4 groups, including control group, electrical stimulation group, [D-Ala2, N-Me-Phe4, Gly5-ol]-enkephalin (DAMGO) group, and [D-Pen 2, D-Pen5]- enkephalin (DPDPE) group. Bilateral IOP was measured after unilateral electrical stimulation of the ARC or unilateral microinjection into the ARC of the selective μ-opioid receptor agonist DAMGO or the selective δ opioid receptor agonist DPDPE, both alone and after pre-administration of either the non-selective opioid receptor antagonist naloxone or saline.

Results

Both electrical stimulation in ARC and micro-injection either <mu> or <delta> opioid receptor agonists, DAMGO or DPDPE, respectively, caused a significant bilateral reduction in IOP (P<0.05) which was more pronounced in the ipsilateral than in the contralateral eye. Pretreatment with naloxone prevented some, but not all IOP reductions.

Conclusion

The ARC takes part in the negative regulation of IOP, an action that may involve opioid neurons.  相似文献   

14.

Purpose

To investigate the effect of ageing on the recovery of ocular blood flow, intravitreal oxygen tension and retinal function during and after intraocular pressure (IOP) elevation.

Methods

Long Evans rats (3- and 14-month-old) underwent acute stepwise IOP elevation from 10 to 120 mmHg (5 mmHg steps each 3 minutes). IOP was then returned to baseline and recovery was monitored for 2 hours. Photopic electroretinograms (ERG) were recorded at each IOP step during stress and at each minute during recovery. Ocular blood flow and vitreal oxygen tension (pO2) were assayed continuously and simultaneously using a combined laser Doppler flow meter (LDF) and an oxygen sensitive fibre-optic probe, respectively. The combined sensor was placed in the vitreous chamber, proximal to the retina. Data were binned into 3 minute intervals during stress and 1 min intervals during recovery. Recovery data was described using a bi-logistic function.

Results

Rats of both ages showed similar susceptibility to IOP elevation, with pO2 showing a closer relationship to ERG than LDF. During recovery, both ages showed a distinctive two-phased recovery for all three measures with the exception of the LDF in 3-month-old rats, which showed only 1 phase. In all animals, LDF recovered fastest (<1 minute), followed by pO2 (<10 minute) and ERG (>1 hour). 14-month-old rats showed surprisingly faster and greater LDF recovery compared to the younger group, with similar levels of pO2 recovery. However, the ERG in these middle-aged animals did not fully recover after two hours, despite showing no difference in susceptibility to IOP during stress compared to the young group.

Conclusions

Young and middle-aged eyes showed similar susceptibility to IOP elevation in terms of pO2, LDF and ERG. Despite this lack of difference during stress, older eyes did not completely recover function, suggesting a more subtle age-related susceptibility to IOP.  相似文献   

15.

Background

To evaluate the efficacy and safety of latanoprost compared with timolol in the treatment of Asian patients with chronic angle-closure glaucoma (CACG).

Methods

Relevant trials were identified through systematic searches of Medline, EMBASE, PubMed, Cochrane Library, Google Scholar and several Chinese databases. The main outcome measures included absolute and relative reduction of intraocular pressure (IOP) at mean, peak and trough from baseline, ocular adverse effects and systemic adverse events.

Results

Seven randomized controlled trials with 685 patients were included. In comparison with timolol, latanoprost reduced absolute IOP in CACG patients by more than 2.3 mmHg (95%CI, 1.8∼2.9, P<0.01), 2.4 mmHg (95%CI, 1.9∼2.9, P<0.01) and 2.5 mmHg (95%CI, 1.6∼3.3, P<0.01) at mean, peak and trough, respectively. As for relative IOP, there is 9.0% (95%CI, 6.6∼11.4, P<0.01), 9.7% (95%CI, 7.6∼11.8, P<0.01), and 10.8% (95%CI, 7.4∼14.3, P<0.01) greater reduction among latanoprost users than among timolol users. The differences were statistically significant at all time points (1, 2, 4, 8, 12, and 24 weeks). More ocular adverse effects (OR = 1.49, 95% CI, 1.05∼2.10, P = 0.02) and less systemic adverse events (OR = 0.46, 95% CI, 0.25∼0.84, P = 0.01) were observed in latanoprost group in comparison with timolol group.

Conclusion

Compared with timolol, latanoprost was significantly more effective in lowering IOP of Asian patients with CACG, with higher risk of ocular adverse effects but lower risk of systemic adverse events, and might be a good substitute for CACG patients.  相似文献   

16.
17.

Objective

To investigate the added diagnostic value of 3.0 Tesla breast MRI over conventional breast imaging in the diagnosis of in situ and invasive breast cancer and to explore the role of routine versus expert reading.

Materials and Methods

We evaluated MRI scans of patients with nonpalpable BI-RADS 3–5 lesions who underwent dynamic contrast-enhanced 3.0 Tesla breast MRI. Initially, MRI scans were read by radiologists in a routine clinical setting. All histologically confirmed index lesions were re-evaluated by two dedicated breast radiologists. Sensitivity and specificity for the three MRI readings were determined, and the diagnostic value of breast MRI in addition to conventional imaging was assessed. Interobserver reliability between the three readings was evaluated.

Results

MRI examinations of 207 patients were analyzed. Seventy-eight of 207 (37.7%) patients had a malignant lesion, of which 33 (42.3%) patients had pure DCIS and 45 (57.7%) invasive breast cancer. Sensitivity of breast MRI was 66.7% during routine, and 89.3% and 94.7% during expert reading. Specificity was 77.5% in the routine setting, and 61.0% and 33.3% during expert reading. In the routine setting, MRI provided additional diagnostic information over clinical information and conventional imaging, as the Area Under the ROC Curve increased from 0.76 to 0.81. Expert MRI reading was associated with a stronger improvement of the AUC to 0.87. Interobserver reliability between the three MRI readings was fair and moderate.

Conclusions

3.0 T breast MRI of nonpalpable breast lesions is of added diagnostic value for the diagnosis of in situ and invasive breast cancer.  相似文献   

18.

Background

Guidelines for the management of blood pressure (BP) in primary care generally suggest that decisions be made on the basis of specific threshold values (e.g. BP 140/90 mmHg); but this fails to adequately accommodate a common cause of variation – the play of chance.

Objective

To determine the impact of chance variability in BP readings on the clinical decision making of general practitioners (GPs) regarding anti-hypertensive treatment and cardiovascular risk management.

Method

We used an internet based study design, where 109 GPs were assigned to manage one of eight case vignettes (guidelines would recommend treatment for only one of the eight) and presented with blood pressure readings that were randomly selected from an underlying population.

Results

Seventeen (15.6%, 17/109) GPs consulted the vignette for whom treatment was recommended, but only 7/17 (41.2%) GPs prescribed treatment, whereas 14/92 (15.2%) GPs prescribed medication to the other vignettes. When deciding to follow-up a vignette GPs were influenced by threshold values for systolic and diastolic BP, but not by the overall cardiovascular risk. If the first reading was a low BP (systolic <140, diastolic <90) GPs were highly likely to discharge the vignette and follow-up a high BP reading (diastolic >90 or systolic BP≥140). Similar factors predicted the decision to prescribe a drug, although the vignette’s cardiovascular risk (>20%) was now statistically significant (p = 0.03).

Conclusions

GP decision making, whilst generally consistent with guidelines, appears to be compromised by chance variation leading to under and over treatment. Interventions to adequately accommodate chance variability into clinical decision making are required.  相似文献   

19.

Purpose

To develop and characterize a mouse model with intraocular pressure (IOP) elevation after laser photocoagulation on the trabecular meshwork (TM), which may serve as a model to investigate the potential of stem cell-based therapies for glaucoma.

Methods

IOP was measured in 281 adult C57BL/6 mice to determine normal IOP range. IOP elevation was induced unilaterally in 50 adult mice, by targeting the TM through the limbus with a 532-nm diode laser. IOP was measured up to 24 weeks post-treatment. The optic nerve damage was detected by electroretinography and assessed by semiautomatic counting of optic nerve axons. Effects of laser treatment on the TM were evaluated by histology, immunofluorescence staining, optical coherence tomography (OCT) and transmission electron microscopy (TEM).

Results

The average IOP of C57BL/6 mice was 14.5±2.6 mmHg (Mean ±SD). After laser treatment, IOP averaged above 20 mmHg throughout the follow-up period of 24 weeks. At 24 weeks, 57% of treated eyes had elevated IOP with the mean IOP of 22.5±2.5 mmHg (Mean ±SED). The difference of average axon count (59.0%) between laser treated and untreated eyes was statistically significant. Photopic negative response (PhNR) by electroretinography was significantly decreased. CD45+ inflammatory cells invaded the TM within 1 week. The expression of SPARC was increased in the TM from 1 to 12 weeks. Histology showed the anterior chamber angle open after laser treatment. OCT indicated that most of the eyes with laser treatment had no synechia in the anterior chamber angles. TEM demonstrated disorganized and compacted extracellular matrix in the TM.

Conclusions

An experimental murine ocular hypertension model with an open angle and optic nerve axon loss was produced with laser photocoagulation, which could be used to investigate stem cell-based therapies for restoration of the outflow pathway integrity for ocular hypertension or glaucoma.  相似文献   

20.

Purpose

To explore whether adaptation reduces the interocular visual latency differences and the induced Pulfrich effect caused by the anisocoria implicit in small-aperture monovision.

Methods

Anisocoric vision was simulated in two adults by wearing in the non-dominant eye for 7 successive days, while awake, an opaque soft contact lens (CL) with a small, central, circular aperture. This was repeated with aperture diameters of 1.5 and 2.5 mm. Each day, monocular and binocular pattern-reversal Visual Evoked Potentials (VEP) were recorded. Additionally, the Pulfrich effect was measured: the task of the subject was to state whether a a 2-deg spot appeared in front or behind the plane of a central cross when moved left-to-right or right-to-left on a display screen. The retinal illuminance of the dominant eye was varied using neutral density (ND) filters to establish the ND value which eliminated the Pulfrich effect for each lens. All experiments were performed at luminance levels of 5 and 30 cd/m2.

Results

Interocular differences in monocular VEP latency (at 30 cd/m2) rose to about 12–15 ms and 20–25 ms when the CL aperture was 2.5 and 1.5 mm, respectively. The effect was more pronounced at 5 cd/m2 (i.e. with larger natural pupils). A strong Pulfrich effect was observed under all conditions, with the effect being less striking for the 2.5 mm aperture. No neural adaptation appeared to occur: neither the interocular differences in VEP latency nor the ND value required to null the Pulfrich effect reduced over each 7-day period of anisocoric vision.

Conclusions

Small-aperture monovision produced marked interocular differences in visual latency and a Pulfrich experience. These were not reduced by adaptation, perhaps because the natural pupil diameter of the dominant eye was continually changing throughout the day due to varying illumination and other factors, making adaptation difficult.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号