共查询到20条相似文献,搜索用时 0 毫秒
1.
2.
3.
4.
Nowak Agnieszka Pacek Gabriela Mrozik Agnieszka 《Reviews in Environmental Science and Biotechnology》2020,19(2):337-354
Reviews in Environmental Science and Bio/Technology - Iodinated X-ray contrast media (ICM) such as diatrizoate, iohexol, iomeprol, iopamidol, and iopromide are commonly used in medical imaging for... 相似文献
5.
The authors present the literature and their own data on the use of a double contrast study of the urethra in 38 male patients with dysuria of various etiology. The investigations were performed with roentgeno-television control using viscid contrast substances (propyliodone) and gel-like triiodinated liquid contrast media (verografin, urografin, triombrast, etc.). A high informative value of the method in the detection of pathological changes in the urethra and the neck of the urinary bladder, lesser risk of the development and lesser severity of urethro-venous refluxes were noted. 相似文献
6.
7.
Effects of anesthetics on systemic hemodynamics in mice 总被引:1,自引:0,他引:1
Janssen BJ De Celle T Debets JJ Brouns AE Callahan MF Smith TL 《American journal of physiology. Heart and circulatory physiology》2004,287(4):H1618-H1624
The aim of this study was to compare the systemic hemodynamic effects of four commonly used anesthetic regimens in mice that were chronically instrumented for direct and continuous measurements of cardiac output (CO). Mice (CD-1, Swiss, and C57BL6 strains) were instrumented with a transit-time flow probe placed around the ascending aorta for CO measurement. An arterial catheter was inserted into the aorta 4 or 5 days later for blood pressure measurements. After full recovery, hemodynamic parameters including stroke volume, heart rate, CO, mean arterial pressure (MAP), and total peripheral resistance were measured with animals in the conscious state. General anesthesia was then induced in these mice using isoflurane (Iso), urethane, pentobarbital sodium, or ketamine-xylazine (K-X). The doses and routes of administration of these agents were given as required for general surgical procedures in these animals. Compared with the values obtained for animals in the conscious resting state, MAP and CO decreased during all anesthetic interventions, and hemodynamic effects were smallest for Iso (MAP, -24 +/- 3%; CO, -5 +/- 7%; n = 15 mice) and greatest for K-X (MAP, -51 +/- 6%; CO, -37 +/- 9%; n = 8 mice), respectively. The hemodynamic effects of K-X were fully antagonized by administration of the alpha(2)-receptor antagonist atipamezole (n = 8 mice). These results indicate that the anesthetic Iso has fewer systemic hemodynamic effects in mice than the nonvolatile anesthetics. 相似文献
8.
9.
The present experiments were carried out to determine the role of nitric oxide in influencing systemic and renal hemodynamics in conscious young sheep. Parameters of cardiovascular function were measured before and for 4 h after intravenous injection of either L-NAME (NG-nitro-L-arginine methyl ester) or D-NAME (N(G)-nitro-D-arginine methyl ester) at doses of 10, 20, or 40 mg/kg in 13 conscious, chronically instrumented young sheep aged 43 +/-5 days. Blood pressure increased and heart rate decreased in a dose-dependent manner following administration of L-NAME. Renal vascular resistance was increased for 10 min following a dose of 10 mg/kg of L-NAME and for 120 min following a dose of 40 mg/kg of L-NAME. The renal vasodilatory response to close arterial injection of 1 microg/kg of acetylcholine was attenuated by L-NAME in a dose-dependent manner. These experiments provide the first information that under normal physiological conditions in conscious young animals, nitric oxide influences systemic and renal hemodynamics. 相似文献
10.
11.
12.
13.
14.
Huang X Yoshikoshi A Hirano K Sakanishi A 《Canadian journal of physiology and pharmacology》2003,81(4):397-404
To evaluate the effects of contrast media (CMs) on erythrocyte aggregation, we measured the erythrocyte sedimentation with Westergren method at 25 degrees C. CMs were diatrizoate (Urografin 76%) for ionic CM and iopamidol (Iopamiron 370) for nonionic CM. Swine red blood cells (RBCs) were suspended in autologous plasma containing diatrizoate (URO), iopamidol (IOP), and saline (SAL) at 6.7% w/w, as well as in plasma alone (PLA), at 40% of the hematocrit. Sigmoid sedimentation curves were fitted to the Puccini et al. (1977) equation, and the average number of RBCs per aggregate m was calculated by Stokes' law against the time t. According to the Murata-Secomb (1988) theory we estimated the collision rate K between two aggregates from dm/dt in the stationary phase during sedimentation. Corresponding to the maximal ESR, the dm/dt (in cells/s) was 0.52 in PLA, 0.09 in SAL, 0.06 in URO and 0.03 in IOP, so that K also decreased in proportion to dm/dt from 145 fL/s in PLA to 8 fL/s in IOP. Both the ionic and nonionic CMs tend to inhibit the RBC aggregation more than that in SAL; the latter iopamidol appears to be inhibitory more than the former diatrizoate in autologous plasma. 相似文献
15.
16.
I V Gannushkina M V Kameneva A L Antelava 《Biulleten' eksperimental'no? biologii i meditsiny》1988,106(11):533-536
It has been shown that intravenous injections of drug-reducing polymers (at a dose of 2 x1 0(-6) g/ml) to rabbits produced a decrease in the total peripheral resistance with an increase in the cardiac output and simultaneous diminution of the mean blood pressure. These hemodynamic effects did not depend on vasodilatation as it had previously been shown. The alterations were retained for not less than 72 hours after one polymer injection; the effects were due to the influence of polymers on the flow structure. 相似文献
17.
Daisuke Kawahara Shuichi Ozawa Kazushi Yokomachi Toru Higaki Takehiro Shiinoki Yoshimi Ohno Yuji Murakami Kazuo Awai Yasushi Nagata 《Reports of Practical Oncology and Radiotherapy》2019,24(5):499-506
ObjectivesThe aim of the current study is to evaluate the accuracy and the precision of raw-data-based relative electron density (REDraw) and the calibration-based RED (REDcal) at a range of low-RED to high-RED for tissue-equivalent phantom materials by comparing them with reference RED (REDref) and to present the difference of REDraw and REDcal for the contrast medium using dual-energy CT (DECT).MethodsThe REDraw images were reconstructed by raw-data-based decomposition using DECT. For evaluation of the accuracy of the REDraw, REDref was calculated for the tissue-equivalent phantom materials based on their specified density and elemental composition. The REDcal images were calculated using three models: Lung-Bone model, Lung-Ti model and Lung-Ti (SEMAR) model which used single-energy metal artifact reduction (SEMAR). The difference between REDraw and REDcal was calculated.ResultsIn the titanium rod core, the deviations of REDraw and REDcal (Lung-Bone model, Lung-Ti model and Lung-Ti model with SEMAR) from REDref were 0.45%, 50.8%, 15.4% and 15.0%, respectively. The largest differences between REDraw and REDcal (Lung-Bone model, Lung-Ti model and Lung-Ti model with SEMAR) in the contrast medium phantom were 8.2%, ?23.7%, and 28.7%, respectively. However, the differences between REDraw and REDcal values were within 10% at 20 mg/ml. The standard deviation of the REDraw was significantly smaller than the REDcal with three models in the titanium and the materials that had low CT numbers.ConclusionThe REDcal values could be affected by beam hardening artifacts and the REDcal was less accurate than REDraw for high-Z materials as titanium.Advances in knowledgeThe raw-data-based reconstruction method could reduce the beam hardening artifact compared with image-based reconstruction and increase the accuracy for the RED estimation in high-Z materials, such as titanium and iodinated contrast medium. 相似文献
18.
19.
20.
To study the reliabiliity of formulas for calculating mean skin temperature (T
sk), values were computed by 18 different techniques and were compared with the mean of 10,841 skin temperatures measured by
infrared thermography. One hundred whole-body infrared thermograms were scanned in ten resting males while changing the air
temperature from 40° C to 4° C. Local, regional average and mean skin temperatures were obtained using an image processing
system. The agreement frequency, defined as the percentage of the calculated T
sk values which agreed with the corresponding infrared thermographic T
sk within ±0.2° C, ranged for with the various formulas from 7% to 80%. In many sites, the local skin temperature did not coincide
with the regional average skin temperature. When the local skin temperatures which showed the highest percentage similarity
to the regional average skin temperature within ±0.4° C were applied to the formula, the agreement frequency was markedly
improved for all formulas. However, the agreement frequency was not affected by changing the weighting factors from specific
constants to individually measured values of regional surface area. By applying the physiologically reliable accuracy range
of ±0.2° C in the moderate and ±0.4° C in the cool condition, agreement frequencies of at least 95% were observed in formulas
involving seven or more skin temperature measurement sites, including the hand and foot. We conclude that calculation of a
reliable mean skin temperature must involve more than seven skin temperature measurement sites regardless of ambient temperature.
Optimal sites for skin temperature measurement are proposed for various formulas.
Received: 2 December 1996 / Accepted: 25 June 1997 相似文献