首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A 65-year-old gentleman with dual chamber pacemaker presented with presyncope. The ECG raised concerns of oversensing which was confirmed by magnet response. The device interrogation revealed noise in ventricular channel temporally associated with P wave. The pacing thresholds were normal. Although the ventricular lead impedance was within normal limit the impedance trend suggested 100 Ω decline over last 1 year. RV lead insulation failure was speculated and supported by the bipolar and unipolar intracardiac electrogram. Device was programmed to DOO temporarily. He underwent RV lead replacement uneventfully.  相似文献   

2.
Wavefront synchronization is an important aspect preceding the termination of ventricular fibrillation (VF). We evaluated the defibrillation efficacy of a novel multisite pacing algorithm using optical recording-guided synchronized pacing (SyncP) in the excitable gaps. We compared the effects of SyncP with traditional overdrive pacing (ODP) at 90% of the VF cycle length (VFCL) and high-frequency pacing (HFP; 43-215 Hz) on spontaneous VF termination in isolated rabbit hearts. For SyncP, the pacing current was triggered by the activation of a reference site and was delivered when the optical potential of the pacing site was in an excitable gap. We measured VFCL and the spatial dispersion of VFCL (SDCL) from five points (3 points in the paced area and 2 points in the nonpaced area) and the distribution of phase singularities during the prepacing, pacing, and postpacing periods. The results showed that 1) the VF termination rate of SyncP (16.0%, n = 106) was higher than that of ODP (2.1%, n = 48, P < 0.01) or HFP (1.6%, n = 129, P < 0.0001); 2) energy consumption for SyncP (7.6 +/- 9.3 mJ) was significantly lower than that of ODP (14.0 +/- 14.8 mJ, P < 0.0001); and 3) SyncP, but not ODP or HFP, decreased SDCL in the paced area during the pacing (P < 0.01) and postpacing (P < 0.05) periods compared with the prepacing period. We conclude that SyncP is effective in inducing wavefront synchronization and is more effective at facilitating spontaneous VF termination than non-SyncP.  相似文献   

3.
4.
Previous studies have suggested that anodal pacing enhances electrical conduction in the heart near the pacing site. It was hypothesized that enhanced conduction by anodal pacing would also enhance ventricular pressure in the heart. Left ventricular pressure measurements were made in isolated, Langendorff-perfused rabbit hearts by means of a Millar pressure transducer with the use of a balloon catheter fixed in the left ventricle. The pressure wave was analyzed for maximum pressure (Pmax) generated in the left ventricle and the work done by the left ventricle (Parea). Eight hearts were paced with monophasic square-wave pulses of varying amplitudes (2, 4, 6, and 8 V) with 100 pulses of each waveform delivered to the epicardium. Anodal stimulation pulses showed statistically significant improvement in mechanical response at 2, 4, and 8 V. Relative to unipolar cathodal pacing, unipolar anodal pacing improved Pmax by 4.4 +/- 2.3 (SD), 5.3 +/- 3.1, 3.5 +/- 4.9, and 4.8 +/- 1.9% at 2, 4, 6, and 8 V, respectively. Unipolar anodal stimulation also improved Parea by 9.0 +/- 3.0, 12.0 +/- 6.0, 10.1 +/- 7.7, and 11.9 +/- 6.0% at 2, 4, 6, and 8 V, respectively. Improvements in Pmax and Parea indicate that an anodally paced heart has a stronger mechanical response than does a cathodally paced heart. Anodal pacing might be useful as a novel therapeutic technology to treat mechanically impaired or failed hearts.  相似文献   

5.
Bai R  Pu J  Liu N  Lu JG  Zhou Q  Ruan YF  Niu HY  Wang L 《生理学报》2003,55(6):722-730
实验以正常犬和扩张型心肌病心力衰竭犬(dilated cardiomyopathy congestive heart failure,DCM-CHF)模型为对象、以心肌跨室壁复极离散的相关参数为指标,研究左心室心外膜起搏、双心室起搏(模拟临床上心室再同步治疗的方法)后的心肌电生理特性变化。实验以快速右心室起搏的方法制备DCM-CHF犬模型;正常犬和DCM-CHF犬均经射频消融希氏束制备三度房室传导阻滞模型;采用同步记录犬体表心电图和内膜下、中层、外膜下三层心肌单相动作电位(monophasic action potentials,MAP)的方法,测定不同部位起搏时的QT间期、Tpeak-Tend(Tp-Te)间期和三层心肌的单相动作电位时程(MAP duration,MAPD)、跨室壁复极离散度(transmural dispersion of repolaization,TDR)。结果显示:在正常犬,左室心外膜与双心室起搏后三层心肌的MAPD均延长,同时TDR增大(左室心外膜起搏47.16 ms、双心室起搏37.54 ms、右室心内膜起搏26.75 ms,P<0.001),体表心电图Tp-Te间期的变化与之平行;在DCM-CHF犬较正常犬已表现出中层心肌MAPD延长(276.30 ms vs 257.35 ms,P<0.0001)和TDR(33.8 ms vs 27.58 ms,P=0.002)增大的基础上,左室心外膜参与起搏后仍进一步使三层心肌的MAPD延长和TDR增大。研究结果提示,左室心外膜起搏和双心室起搏后使内膜下、中层  相似文献   

6.
The influence of the intracardiac reflectory system on the atrioventricular propagation in the experiments on the isolated frog's heart has been investigated. The ability of the intracardiac reflectory cholinergic activation to accelerate or reduce the atrioventricular propagation was confirmed. Both effects remain on the background of the artificially stabilized heart rhythm. The dromotropic effect direction was shown not to be connected with the electrocardiogram (ECG) phase at which the stimulus has been given; the positive or negative dromotropic effect can appear giving the stimulus at the same phase of the ECG. But there is a strong correlation between the moment of the stimulation and the dromotropic effect intensity. The most high degree of the acceleration and inhibition appears when the stimulus is given near the P component of the ECG.  相似文献   

7.
Atrial arrhythmias, primarily atrial fibrillation, have been independently associated with structural remodeling and with inflammation. We hypothesized that sustained inflammatory signaling by tumor necrosis factor (TNF) would lead to alterations both in underlying atrial myocardial structure and in atrial electrical conduction. We performed ECG recording, intracardiac electrophysiology studies, epicardial mapping, and connexin immunohistochemical analyses on transgenic mice with targeted overexpression of TNF in the cardiac compartment (MHCsTNF) and on wild-type (WT) control mice (age 8-16 wk). Atrial and ventricular conduction abnormalities were always evident on ECG in MHCsTNF mice, including a shortened atrioventricular interval with a wide QRS duration secondary to junctional rhythm. Supraventricular arrhythmias were observed in five of eight MHCsTNF mice, whereas none of the mice demonstrated ventricular arrhythmias. No arrhythmias were observed in WT mice. Left ventricular conduction velocity during apical pacing was similar between the two mouse groups. Connexin40 was significantly downregulated in MHCsTNF mice. In contrast, connexin43 density was not significantly altered in MHCsTNF mice, but rather dispersed away from the intercalated disks. In conclusion, sustained inflammatory signaling contributed to atrial structural remodeling and downregulation of connexin40 that was associated with an increased prevalence of atrial arrhythmias.  相似文献   

8.
There is a lack of standard methods for the analysis of magnetocardiograms (MCGs). MCG signals have a shape similar to the ECG (P wave, QRS complex, T wave). High-quality multichannel recordings can indicate even slight disturbances of de- and repolarisation. The purpose of our study was to apply a new approach in the analysis of signal-averaged DC-MCGs. DC-MCGs (31-channel) were recorded in 182 subjects: 110 patients after myocardial infarction and 72 controls. Spatiotemporal correlation analysis of the QRS complex and T wave patterns throughout the entire heart cycle was used to analyse homogeneity of de- and repolarisation. These plots were compared to standard ECG analyses (electrical axis, Q wave, ST deviation, T polarity and shape). Spatiotemporal correlation analyses seem to be applicable in assessing the course of electrical repolarisation with respect to homogeneity. MCG provided all diagnostic information contained in common ECG recordings at high significance levels. The ECG patterns were included in 5/8 of our parameters for electrical axis, 6/8 for Q-wave, 7/8 for ST deviation and 5/8 for T-polarity based on two time series of correlation coefficients. We conclude that our spatiotemporal correlation approach provides a new tool for standardised analysis of cardiac mapping data such as MCG.  相似文献   

9.
Electrocardiograms by standard limb lead, augumented unipolar limb lead and AB (Apex-Base) lead were recorded from 24 unanesthetized adult cats from a SPF closed colony. The unanesthetized cats were held in the sternal position or in the right lateral recumbent position by means of a net. The mean electrical axes of P, QRS and T waves were calculated on the basis of values of I, II and III leads. The ECG patterns and mean electrical axes were compared between the sternal position and the right lateral recumbent position. The results are summarized as follows. The mean values of RR duration, P wave duration, QRS complex duration, T wave duration, PQ interval and QT interval were 0.432, 0.033, 0.027, 0.101, 0.076 and 0.183 seconds, respectively. The values of duration, interval and amplitude were not prominently influenced by the change in posture. The ECG shape had a definite configuration on each lead except that leads I and a VL showed unstable patterns. Notches and R' waves appeared in every lead in many cases. There was a positive linear correlation between RR and QT duration: r = 0.798 in the sternal position and r = 0.525 in the right lateral recumbent position. The angle of QRS mean electrical axis on the horizontal plane was 66.90 degrees +/- 26.05 (SD) in the sternal position and 41.84 degrees +/- 75.23 (SD) in the right lateral recumbent position. The P and T mean electrical axes showed small variations.  相似文献   

10.
In order to develop effective counter measures to cardiovascular maladaptation associated with space flight, it is essential to know how dynamic characteristics of blood pressure regulation are altered in space. The open-loop transfer characteristics of the carotid sinus baroreflex can be divided into the neural arc and peripheral arc transfer functions (Ikeda et al. 1996). The neural arc transfer function represents the dynamic input-output characteristics from arterial pressure (AP) to efferent sympathetic nerve activity (SNA), while the peripheral arc transfer function represents those from SNA to AP. Although AP perturbation according to a white noise sequence can be used to estimate the transfer functions under baroreflex closed-loop conditions (Kwanda et al. 1997), arterial catheter implantation necessary to perturb AP limits the applicability of this method to freely moving animal experiments. To overcome this problem, we explored the closed-loop system identification method using electrical stimulation. We used aortic depressor nerve (ADN) stimulation and rapid pacing (RP) of the heart to perturb the arterial baroreflex system.  相似文献   

11.
The present study examined whether the gain of the transfer function relating cardiac-related rhythm of renal sympathetic nerve activity (RSNA) to arterial pressure (AP) pulse might serve as a spontaneous index of sympathetic baroreflex sensitivity (BRS). AP and RSNA were simultaneously recorded in conscious rats, either baroreceptor-intact (control, n = 11) or with partial denervation of baroreflex afferents [aortic baroreceptor denervated (ABD; n = 10)] during 1-h periods of spontaneous activity. Transfer gain was calculated over 58 adjacent 61.4-s periods (segmented into 10.2-s periods). Coherence between AP and RSNA was statistically (P < 0.05) significant in 90 +/- 3% and 56 +/- 10% of cases in control and ABD rats, respectively. Transfer gain was higher (P = 0.0049) in control [2.39 +/- 0.13 normalized units (NU)/mmHg] than in ABD (1.48 +/- 0.22 NU/mmHg) rats. In the pooled study sample, transfer gain correlated with sympathetic BRS estimated by the vasoactive drug injection technique (R = 0.75; P < 0.0001) and was inversely related to both time- (standard deviation; R = -0.74; P = 0.0001) and frequency-domain [total spectral power (0.00028-2.5 Hz); R = -0.82; P < 0.0001] indices of AP variability. In control rats, transfer gain exhibited large fluctuations (coefficient of variation: 34 +/- 3%) that were not consistently related to changes in the mean level of AP, heart rate, or RSNA. In conclusion, the transfer function method provides a continuous, functionally relevant index of sympathetic BRS and reveals that the latter fluctuates widely over time.  相似文献   

12.
Our objective was to create an animal preparation displaying long-term electrical alterations after chronic regional energetic stress without myocardial scarring. An Ameroid (AM) constrictor was implanted around the left circumflex coronary artery (LCx) 2 wk before chronic rapid ventricular pacing (CRP) was initiated at 240 beats/min for 4 wk (CRP-AM). Comparisons were made with healthy canines and canines with either AM or CRP. Unipolar electrograms were recorded from 191 sites in the LCx territory in open-chest, anesthetized animals during sinus rhythm and while pacing at 120-150 beats/min, with bouts of transient rapid pacing (TRP; 240/min). In CRP-AM and AM, ST segment elevation was identified at central sites and ST depression at peripheral sites, both increasing with TRP. In CRP-AM and CRP, the maximum negative slope of unipolar activation complexes was significantly depressed and activation-recovery intervals prolonged. Areas of inexcitability as well as irregular isocontour patterns displaying localized activation-recovery intervals shortening and gradients >20 ms between neighboring sites were identified in one-third of CRP-AM at slow rate, with increasing incidence and magnitude in response to TRP. In CRP-AM, programmed stimulation-induced marked conduction delay and block as well as polymorphic ventricular tachycardias, which stabilized into monomorphic tachycardias with the use of lidocaine or procainamide. Whole cell Na(+) current and channel protein expression were reduced in CRP-AM and CRP. Despite complete constrictor closure, small areas of necrosis were detected in a minority of CRP-AM. Long-term electrical alterations and their exacerbation by TRP contribute to arrhythmia formation in collateral-dependent myocardium subjected to chronic tachycardic stress.  相似文献   

13.
Multiple imaging modalities are employed independent of one another while managing complex cardiac arrhythmias. To combine electrical, anatomical, and functional imaging in a single catheter system, we developed a balloon catheter that carried 64 electrodes on its surface and an intracardiac echocardiography (ICE) catheter through a central lumen. The catheter system was inserted, and the balloon was inflated inside the left ventricle (LV) of eight dogs with 6-wk-old infarction, created by occlusion in the left anterior descending coronary artery. Anatomy was constructed by ICE imaging (9 MHz) through the balloon. Single-beat noncontact mapping (NCM) was performed via the multielectrode array to reconstruct unipolar endocardial electrograms during sinus rhythm. Standard contact mapping (CM) of the endocardium was also carried out for reference. Myocardial infarction in anterior LV extending from the middle to apical regions was localized both by ICE and NCM and validated by CM and pathology. The overall difference in the activation times between NCM and CM was 3 +/- 1 ms. Unipolar voltage in infarcted middle anterior LV was smaller than the voltage in normal middle inferior LV both by NCM (11 +/- 4 vs. 16 +/- 3 mV; P = 0.002) and CM (11 +/- 3 vs. 20 +/- 4 mV; P < 0.001). Unipolar voltage was also inversely related to infarct transmurality, both by NCM (r = -0.87; P = 0.005) and CM (r = -0.94; P < 0.001). The infarct area by ICE (7.7 +/- 2.9 cm(2)) was in agreement with CM (bipolar voltage, <1 mV; and area, 7.6 +/- 3.3 cm(2); r = 0.80; P = 0.016). Meanwhile, the voltage threshold that depicted the infarct area by NCM was directly related to the smallest unipolar voltage reconstructed within the infarct (r = 0.96; P < 0.001). In conclusion, combining NCM and ICE imaging in a single catheter system is feasible. The preclinical development of such an integrated system and its evaluation in experimental myocardial infarction demonstrate capabilities for single-beat mapping at multiple sites as well as the online assessment of anatomy and myocardial function.  相似文献   

14.
A numerical method is described for finding steady state and transient responses in electrically linear, spatially inhomogeneous cables. Spatial inhomogeneities are incorporated by representing the cable by a number of finite length uniform cylindrical segments, each having the radius and electrical characteristics of a small region along the cable. Input waveforms are approximated by truncated Fourier series of sinusoidal components. Output waveforms are produced by multiplying the input Fourier series sinusoids by their respective transfer functions between input and output points on the cable and summing the resultant output point sinusoids. The transfer functions, representing attenuation and phase shift for each input sinusoid, are obtained by numerical analysis of an electrical ladder network derived from the cylindrical segment model of the cable. Results are shown for application of this method to both cylindrical and expanding radius cable geometries.  相似文献   

15.
The human immunodeficiency virus (HIV)-lipodystrophy syndrome is characterized by abnormalities of lipid metabolism, glucose homeostasis, and fat distribution. Overaccumulation of intramuscular lipid may contribute to insulin resistance in this population. We examined 63 men: HIV positive with lipodystrophy (n = 22), HIV positive without lipodystrophy (n = 20), and age- and body mass index-matched HIV-negative controls (n = 21). Single-slice computed tomography was used to determine psoas muscle attenuation and visceral fat area. Plasma free fatty acids (FFA), lipid profile, and markers of glucose homeostasis were measured. Muscle attenuation was significantly decreased in subjects with lipodystrophy [median (interquartile range), 55.0 (51.0-58.3)] compared with subjects without lipodystrophy [57.0 (55.0-59.0); P = 0.05] and HIV-negative controls [59.5 (57.3-64.8); P < 0.01]. Among HIV-infected subjects, muscle attenuation correlated significantly with FFA (r = -0.38; P = 0.02), visceral fat (r = -0.49; P = 0.002), glucose (r = -0.38; P = 0.02) and insulin (r = -0.60; P = 0.0001) response to a 75-g oral glucose tolerance test. In forward stepwise regression analysis with psoas attenuation as the dependent variable, visceral fat (P = 0.02) and FFA (P < 0.05), but neither body mass index, subcutaneous fat, nor antiretroviral use, were strong independent predictors of muscle attenuation (r2 = 0.39 for model). Muscle attenuation (P = 0.02) and visceral fat (P = 0.02), but not BMI, subcutaneous fat, FFA, or antiretroviral use, were strong independent predictors of insulin response (area under the curve) to glucose challenge (r2 = 0.47 for model). These data demonstrate that decreased psoas muscle attenuation due to intramuscular fat accumulation may contribute significantly to hyperinsulinemia and insulin resistance in HIV-lipodystrophy patients. Further studies are needed to assess the mechanisms and consequences of intramuscular lipid accumulation in HIV-infected patients.  相似文献   

16.
We sought to explore the distribution pattern of Na(+) channels across ventricular wall, and to determine its functional correlates, in the guinea pig heart. Voltage-dependent Na(+) channel (Na(v)) protein expression levels were measured in transmural samples of ventricular tissue by Western blotting. Isolated, perfused heart preparations were used to record monophasic action potentials and volume-conducted ECG, and to measure effective refractory periods (ERPs) and pacing thresholds, in order to assess excitability, electrical restitution kinetics, and susceptibility to stimulation-evoked tachyarrhythmias at epicardial and endocardial stimulation sites. In both ventricular chambers, Na(v) protein expression was higher at endocardium than epicardium, with midmyocardial layers showing intermediate expression levels. Endocardial stimulation sites showed higher excitability, as evidenced by lower pacing thresholds during regular stimulation and downward displacement of the strength-interval curve reconstructed after extrasystolic stimulation compared with epicardium. ERP restitution assessed over a wide range of pacing rates showed greater maximal slope and faster kinetics at endocardial than epicardial stimulation sites. Flecainide, a Na(+) channel blocker, reduced the maximal ERP restitution slope, slowed restitution kinetics, and eliminated epicardial-to-endocardial difference in dynamics of electrical restitution. Greater excitability and steeper electrical restitution have been associated with greater arrhythmic susceptibility of endocardium than epicardium, as assessed by measuring ventricular fibrillation threshold, inducibility of tachyarrhythmias by rapid cardiac pacing, and the magnitude of stimulation-evoked repolarization alternans. In conclusion, higher Na(+) channel expression levels may contribute to greater excitability, steeper electrical restitution slopes and faster restitution kinetics, and greater susceptibility to stimulation-evoked tachyarrhythmias at endocardium than epicardium in the guinea pig heart.  相似文献   

17.
Genetically-modified mice have emerged as a preferable animal model to study the molecular mechanisms underlying conduction abnormalities, atrial and ventricular arrhythmias, and sudden cardiac death.1 Intracardiac pacing studies can be performed in mice using a 1.1F octapolar catheter inserted into the jugular vein, and advanced into the right atrium and ventricle. Here, we illustrate the steps involved in performing programmed electrical stimulation in mice. Surface ECG and intracardiac electrograms are recorded simultaneously in the atria, atrioventricular junction, and ventricular myocardium, whereas intracardiac pacing of the atrium is performed using an external stimulator. Thus, programmed electrical stimulation in mice provides unique opportunities to explore molecular mechanisms underlying conduction defects and cardiac arrhythmias.Download video file.(84M, mp4)  相似文献   

18.
This study examined the possible influence of changes in heart rate (HR) on the gain of the transfer function relating renal sympathetic nerve activity (RSNA) to arterial pressure (AP) at HR frequency in rats. In seven urethane-anesthetized rats, AP and RSNA were recorded under baseline conditions (spontaneous HR = 338 +/- 6 beats/min, i.e., 5.6 +/- 0.1 Hz) and during 70-s periods of cardiac pacing at 6-9 Hz applied in random order. Cardiac pacing slightly increased mean AP (0.8 +/- 0.2 mmHg/Hz) and decreased pulse pressure (-3.6 +/- 0.3 mmHg/Hz) while leaving the mean level of RSNA essentially unaltered (P = 0.680, repeated-measures ANOVA). The gain of the transfer function from AP to RSNA measured at HR frequency was always associated with a strong, significant coherence and was stable between 6 and 9 Hz (P = 0.185). The transfer function gain measured under baseline conditions [2.44 +/- 0.28 normalized units (NU)/mmHg] did not differ from that measured during cardiac pacing (2.46 +/- 0.27 NU/mmHg). On the contrary, phase decreased linearly as a function of HR, which indicated the presence of a fixed time delay (97 +/- 6 ms) between AP and RSNA. In conclusion, the dynamic properties of arterial baroreflex pathways do not affect the gain of the transfer function between AP and RSNA measured at HR frequency in the upper part of the physiological range of HR variations in the rat.  相似文献   

19.
The variations in ventricular-atrial mitral annular position during the cardiac cycle and the simultaneous changes in left atrial silhouette area (obtained by angiography after injections of contrast material into the main pulmonary artery) were investigated in six experiments on intact dogs with chronically implanted intracardiac markers. Frame-by-frame measurements of the angiograms (120 frames/s) were used to determine, under various hemodynamic conditions, the duration, magnitude, and average rate of the mitral annular motion and of the simultaneous changes in left atrial area during atrial filling (ventricular systole) and atrial emptying (early in ventricular diastole). The mitral annulus was seen to move towards the ventricular apex during systole and towards the atrium early in diastole with the duration, average rate, and magnitude of displacement (although varying widely) showing good statistical correlations (P less than 0.0005-0.005) with the changes in projected left atrial area. These findings suggest that the duration, rate, and magnitude of atrial filling and emptying may be, in the intact heart, determined by the movements of the atrioventricular junction.  相似文献   

20.
Studies of atrial electrophysiology (EP) in rodents are challenging, and available data are sparse. Herein, we utilized a novel type of bipolar electrode to evaluate the atrial EP of rodents through small lateral thoracotomy. In anesthetized rats and mice, we attached two bipolar electrodes to the right atrium and a third to the right ventricle. This standard setup enabled high-resolution EP studies. Moreover, a permanent implantation procedure enabled EP studies in conscious freely moving rats. Atrial EP was evaluated in anesthetized rats, anesthetized mice (ICR and C57BL6 strains), and conscious rats. Signal resolution enabled atrial effective refractory period (AERP) measurements and first time evaluation of the failed 1:1 atrial capture, which was unexpectedly longer than the AERP recorded at near normal cycle length by 27.2+/-2.3% in rats (P<0.0001; n=35), 31.7+/-8.3% in ICR mice (P=0.0001; n=13), and 57.7+/-13.7% in C57BL6 mice (P=0.015; n=4). While AERP rate adaptation was noted when 10 S1s at near normal basic cycle lengths were followed by S2 at varying basic cycle length and S3 for AERP evaluation, such rate adaptation was absent using conventional S1S2 protocols. Atrial tachypacing in rats shortened the AERP values on a timescale of hours, but a reverse remodeling phase was noted thereafter. Comparison of left vs. right atrial pacing in rats was also feasible with the current technique, resulting in similar AERP values recorded in the low right atrium. In conclusion, our findings indicate that in vivo rate adaptation of the rodent atria is different than expected based on previous ex vivo recordings. In addition, atrial electrical remodeling of rats shows unique remodeling-reverse remodeling characteristics that are described here for the first time. Further understanding of these properties should help to determine the clinical relevance as well as limitations of atrial arrhythmia models in rodents.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号