首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 516 毫秒
1.
目的 调查医院各病区环境中真菌含量及分布特点.方法 运用分离培养及DNA测序方法对医院不同病区、不同环境中真菌进行监测分析.结果 医院不同病区真菌含量不同,呼吸科、血液科、小儿科空气中真菌含量较高,分别为400、225和200 CFU/m3,其中以烟曲霉菌( 325 CFU/m3)、黄曲霉菌( 275 CFU/m3)、枝孢霉菌( 125 CFU/m3)、根霉( 125 CFU/m3)为主;老年病科、肿瘤科和血液科空调出气口真菌含量较高,分别为0.559、0.500和0.323 CFU/cm2,以链格孢霉(0.441 CFU/cm2)、根霉(0.412 CFU/cm2)、烟曲霉菌(0.294 CFU/cm2)为主;不同环境中真菌含量不同,其中以空气和空调出气口真菌含量最高,分别为130 CFU/m3、0.173 CFU/cm2.结论 真菌广泛存在于医院环境中,且不同病区、不同环境真菌污染程度不同,因而我们必须制订健全的消毒管理制度,预防医院真菌感染.  相似文献   

2.
The fungal concentration and flora in indoor and outdoor air in Yokohama, Japan were analyzed with a Reuter centrifugal air sampler and dichloran 18% glycerol agar (DG18), and compared with the levels assessed with potato dextrose agar (PDA). The number of fungal colony-forming units (CFU) in outdoor air was < 13–2750/m3; Cladosporium spp. predominated, followed by Alternaria spp. and Penicillium spp. The fungal concentration in outdoor air peaked in September. The concentrations of fungi in outdoor air (n = 288) were significantly correlated with the maximum temperature of the day, minimum temperature of the day, average temperature of the day, average velocity of wind of the day, average temperature of the month, average relative humidity of the month and precipitation of the month. In indoor air, the fungal CFU was < 13–3750/m3. Cladosporium spp. predominated, followed by the xerophilic fungi such as the Aspergillus restrictus group, Wallemia sebi, the A. glaucus group, and Penicillium spp. The fungal concentration in indoor air peaked in October. The concentrations of fungi in indoor air (n = 288) were significantly correlated with the indoor temperature, indoor relative humidity and the outdoor climatic factors mentioned above, except for the average velocity of wind of the day. This revised version was published online in June 2006 with corrections to the Cover Date.  相似文献   

3.
Indoor microbial exposure has been related to adverse pulmonary health effects. Exposure assessment is not standardized, and various factors may affect the measured exposure. The aim of this study was to investigate the seasonal variation of selected microbial exposures and their associations with temperature, relative humidity, and air exchange rates in Danish homes. Airborne inhalable dust was sampled in five Danish homes throughout the four seasons of 1 year (indoors, n = 127; outdoors, n = 37). Measurements included culturable fungi and bacteria, endotoxin, N-acetyl-beta-d-glucosaminidase, total inflammatory potential, particles (0.75 to 15 μm), temperature, relative humidity, and air exchange rates. Significant seasonal variation was found for all indoor microbial exposures, excluding endotoxin. Indoor fungi peaked in summer (median, 235 CFU/m3) and were lowest in winter (median, 26 CFU/m3). Indoor bacteria peaked in spring (median, 2,165 CFU/m3) and were lowest in summer (median, 240 CFU/m3). Concentrations of fungi were predominately higher outdoors than indoors, whereas bacteria, endotoxin, and inhalable dust concentrations were highest indoors. Bacteria and endotoxin correlated with the mass of inhalable dust and number of particles. Temperature and air exchange rates were positively associated with fungi and N-acetyl-beta-d-glucosaminidase and negatively with bacteria and the total inflammatory potential. Although temperature, relative humidity, and air exchange rates were significantly associated with several indoor microbial exposures, they could not fully explain the observed seasonal variations when tested in a mixed statistical model. In conclusion, the season significantly affects indoor microbial exposures, which are influenced by temperature, relative humidity, and air exchange rates.  相似文献   

4.

In recent years, monitoring of airborne bacteria and fungi concentrations has obtained increasing universal attraction not only for influences on ecological balance but also for evaluating their public health consequences. In this study, we aimed to investigate culturable airborne bacteria and fungi levels in different sites of Abadan, and their association with meteorological parameters and PM2.5 levels. Abadan is one of the most industrialized cities in the southwest of Iran where over the current decade has experienced lots of dust storm episodes. In total, 400 air samples were collected in 6 months (autumn and winter) using a single-stage viable Andersen cascade impactor for sampling airborne bacteria and fungi and portable DustTrak Aerosol Monitor 8520 for measuring PM2.5 concentrations and meteorological parameters. Microbial concentrations showed a significant difference between various sites over the study period with averages of 569.57?±?312.64 and 482.73?±?242.86 CFU/M3 for bacteria and fungi, respectively. The air temperature had a significant effect on the concentration of both airborne bacteria and fungi. A significant positive correlation between relative humidity and fungi but no correlation between relative humidity and bacteria concentrations were observed. The average airborne PM2.5 concentrations of all sites among the study period was 93.24?±?116.72 μg/m3. The atmospheric bacterial and fungal communities were strongly positively correlated with the ambient PM2.5 level. The levels of airborne bacteria and fungi along with PM2.5 in the air of the city were relatively higher than the recommended levels. Therefore, the best course of action is needed to control emission sources. Further studies are also needed to evaluate the clinical analysis of the health effects of exposure to these pollutants.

  相似文献   

5.
There is a growing interest in indoor air quality for a better quality environment both at home and at work because many people spend at least 80% of their time indoors. The aim of our study was to evaluate the indoor concentration of airborne bacteria and fungi in a University auditorium, in an office of public buildings and in an apartment in the presence and in absence of building's occupants, building materials and furnishings. The concentrations of airborne bacteria and fungi were determined using a Surface Air System (SAS). In presence of people and furnishings the average air concentrations of bacteria (University auditorium: 925-1225 CFU m(-3); office: 493 CFU m(-3); apartment: 92-182 CFU m(-3)) were higher than in absence (respectively: 190-315 CFU m(-3); 126 CFU m(-3); 66-80 CFU m(-3)). The average air concentrations fungal were higher in presence of people and furnishings (University auditorium: 1256-1769 CFU m(-3); office: 858 CFU m(-3); apartment: 147-297 CFU m(-3)) than in absence (respectively: 301-431 CFU m(-3); 224 CFU m(-3); 102-132 CFU m(-3)). The obtained data can be considered as a step to identify acceptable levels for bioaerosols in common indoor environments.  相似文献   

6.
During 1 year, samples were taken on 4 days, one sample in each season, from pigs, the floor, and the air inside pig barns and from the ambient air and soil at different distances outside six commercial livestock-associated methicillin-resistant Staphylococcus aureus (LA-MRSA)-positive pig barns in the north and east of Germany. LA-MRSA was isolated from animals, floor, and air samples in the barn, showing a range of airborne LA-MRSA between 6 and 3,619 CFU/m(3) (median, 151 CFU/m(3)). Downwind of the barns, LA-MRSA was detected in low concentrations (11 to 14 CFU/m(3)) at distances of 50 and 150 m; all upwind air samples were negative. In contrast, LA-MRSA was found on soil surfaces at distances of 50, 150, and 300 m downwind from all barns, but no statistical differences could be observed between the proportions of positive soil surface samples at the three different distances. Upwind of the barns, positive soil surface samples were found only sporadically. Significantly more positive LA-MRSA samples were found in summer than in the other seasons both in air and soil samples upwind and downwind of the pig barns. spa typing was used to confirm the identity of LA-MRSA types found inside and outside the barns. The results show that there is regular airborne LA-MRSA transmission and deposition, which are strongly influenced by wind direction and season, of up to at least 300 m around positive pig barns. The described boot sampling method seems suitable to characterize the contamination of the vicinity of LA-MRSA-positive pig barns by the airborne route.  相似文献   

7.
The results of 100 carpet dust analyses from atopic individuals' environment were compared according to the sampling period or the location. Dust samples were collected with a standard domestic vacuum cleaner, in locations with carpeted floor: in residences (living-room and/or bedroom), in school classrooms and in offices. The quantities of fungi vary from 5000 CFU/g to 66 000 000 CFU/g of dust. More than 100 species were isolated by dilution plating. The main species found in carpet dust wereEurotium repens, Penicillium chrysogenum, Alternaria alternata, Aureobasidium pullulans andPhoma herbarum. Strict xerophilic species were rather rare and detected in small quantities. Differences in the distribution of the CFU concentrations were examined for the four different sampling locations and were statistically significant (P=0.0174). In this study, schools were open spaces, and offices, mostly with air conditioning systems, were locations in which air is not confined. This, added to frequent professional carpet cleaning, probably explains the lowest levels of fungal concentration found in these locations. The majority of the homes had the largest fungal concentration in the living-room (median: 2×105 CFU/g) while some bedrooms (median: 7×104 CFU/g) had the highest concentrations. It is suggested that, when fungi are suspected to be the origin of respiratory allergy or irritating symptoms, the mycoflora of the bedroom, principally, should be investigated first.  相似文献   

8.
This paper is a speleomycological report from a former aluminous shale mine in Janowiec, Poland. Fungi were identified morphologically and molecularly. Microclimatic conditions differed significantly between locations of the study. However, the external environment around the mine did not directly increase the community composition and concentration of fungi in the mine. The density of fungi isolated from the air outside the mine was 63.1 colony forming units (CFU) per 1 cm3 of air. Inside the mine, fungal density ranged from 287.5 to 655 CFU per 1 m3 from the air, 28.4 to 131.1 CFU per 1 cm2 from the rock surfaces and 288.1 to 335.1 CFU per 1 cm3 from the water. Pearson correlation analysis showed that the levels of fungi isolated from the air were correlated positively with temperature, relative humidity and CO2 concentration. The concentration of fungi isolated from the rock surfaces showed a positive correlation with air flow. Five species of filamentous fungi were isolated from the sampled external air, 10 species from the internal air, six species from the rock surface and 11 species from the water. The fungi most frequently isolated from the air and water of the mine belonged to Penicillium spp., whereas from the rock surface, Geomyces pannorum was most frequently isolated. Some of the fungi present in the mine can be psychrotolerant and pathogenic for humans and animals, and they can also cause degradation of rocks.  相似文献   

9.
The results of 100 carpet dust analyses from atopic individuals' environment were compared according to the sampling period or the location. Dust samples were collected with a standard domestic vacuum cleaner, in locations with carpeted floor: in residences (living-room and/or bedroom), in school classrooms and in offices. The quantities of fungi vary from 5000 CFU/g to 66 000 000 CFU/g of dust. More than 100 species were isolated by dilution plating. The main species found in carpet dust wereEurotium repens, Penicillium chrysogenum, Alternaria alternata, Aureobasidium pullulans andPhoma herbarum. Strict xerophilic species were rather rare and detected in small quantities. Differences in the distribution of the CFU concentrations were examined for the four different sampling locations and were statistically significant (P=0.0174). In this study, schools were open spaces, and offices, mostly with air conditioning systems, were locations in which air is not confined. This, added to frequent professional carpet cleaning, probably explains the lowest levels of fungal concentration found in these locations. The majority of the homes had the largest fungal concentration in the living-room (median: 2×105 CFU/g) while some bedrooms (median: 7×104 CFU/g) had the highest concentrations. It is suggested that, when fungi are suspected to be the origin of respiratory allergy or irritating symptoms, the mycoflora of the bedroom, principally, should be investigated first.  相似文献   

10.
Limited data are currently available on the concentrations of airborne bacteria, fungi, and endotoxins in indoor environments. The levels of aerial bacteria and fungi were measured at several microenvironments within a well-ventilated residential apartment in Singapore including the living room, kitchen, bedroom, toilet, and at a workplace environment by sampling indoor air onto culture medium plates using the 6-stage Andersen sampler. Total microbial counts were determined by collecting the air samples in water with the Andersen sampler, staining the resultant extracts with a fluorescent dye, acridine orange, and counting the microbes using a fluorescent microscope. The levels of airborne endotoxins were also determined by sampling the airborne microorganisms onto 0.4?μm polycarbonate membrane filter using the MiniVol sampler at 5?l/min for 20?h with a PM2.5 cut-off device. The aerial bacterial and fungal concentrations were found to be in the ranges of 117–2,873?CFU/m3 and 160–1,897?CFU/m3, respectively. The total microbial levels ranged from 49,000 to 218,000?microbes/m3. The predominant fungi occurring in the apartment were Aspergillus and Penicillium while the predominant bacterial strains appeared to be Staphylococcus and Micrococcus. The average indoor endotoxin level was detectable in the range of 6–39?EU/m3. The amount of ventilation and the types of human activities carried out in the indoor environment appeared to be important factors affecting the level of these airborne biological contaminants.  相似文献   

11.
Three samples of silage taken from the surface of a silo and from depths of 20 and 45 cm in the silo were studied for identification of the potential agents causing symptoms of organic dust toxic syndrome. The samples were examined by dilution plating before and after aerosolization in an acoustical dust generator. Aerosol samples were collected by liquid impinger and filter cassettes. The samples were examined for total aerobic bacteria, anaerobic bacteria, gram-negative bacteria, lactobacilli, listeriae, thermophilic actinomycetes, fungi, and endotoxin. Very high levels of total aerobic bacteria and fungi were found in the surface sample (up to 10(9) CFU/g in the bulk sample and up to 10(9) CFU/m3 after aerosolization), whereas the corresponding values from the deepest site were 100 to 50,000 times lower. Aspergillus fumigatus predominated among the fungi, whereas Bacillus and gram-negative organisms (Pseudomonas, Alcaligenes, Citrobacter, and Klebsiella species) prevailed among bacteria. Thermophilic actinomycetes occurred in numbers up to 10(7) CFU/g in the bulk samples, whereas anaerobic bacteria, lactobacilli, and listeriae were only few or absent. The concentration of endotoxin was high in the surface sample (up to 211.4 Endotoxin Units/mg) and about 200-fold lower in the sample from the deepest site. The results show that contact with dust from the surface of silage carries the risk of exposure to high concentrations of microorganisms, of which A. fumigatus and endotoxin-producing bacteria are the most probable disease agents.  相似文献   

12.
Three samples of silage taken from the surface of a silo and from depths of 20 and 45 cm in the silo were studied for identification of the potential agents causing symptoms of organic dust toxic syndrome. The samples were examined by dilution plating before and after aerosolization in an acoustical dust generator. Aerosol samples were collected by liquid impinger and filter cassettes. The samples were examined for total aerobic bacteria, anaerobic bacteria, gram-negative bacteria, lactobacilli, listeriae, thermophilic actinomycetes, fungi, and endotoxin. Very high levels of total aerobic bacteria and fungi were found in the surface sample (up to 10(9) CFU/g in the bulk sample and up to 10(9) CFU/m3 after aerosolization), whereas the corresponding values from the deepest site were 100 to 50,000 times lower. Aspergillus fumigatus predominated among the fungi, whereas Bacillus and gram-negative organisms (Pseudomonas, Alcaligenes, Citrobacter, and Klebsiella species) prevailed among bacteria. Thermophilic actinomycetes occurred in numbers up to 10(7) CFU/g in the bulk samples, whereas anaerobic bacteria, lactobacilli, and listeriae were only few or absent. The concentration of endotoxin was high in the surface sample (up to 211.4 Endotoxin Units/mg) and about 200-fold lower in the sample from the deepest site. The results show that contact with dust from the surface of silage carries the risk of exposure to high concentrations of microorganisms, of which A. fumigatus and endotoxin-producing bacteria are the most probable disease agents.  相似文献   

13.
This study aimed to remove complex odorous gas produced from composting using a biotrickling filter and to observe the temporal and special distributions of bacteria, fungi, and actinomycetes. The removal efficiencies of the total volatile organic compounds (TVOC) were 26.1% and 81.5% before and after inoculation of volatile organic compounds (VOC)-degrading microbes, respectively. Especially trimethylamine was 100% degraded. In the first and second composting period, the odor reduction efficiencies showed average values of 86.2% and 94.5%, respectively. The total average of the bacteria in the biofilm was 2.06 × 109 CFU/g TS, which was 22.2% higher than that of the control (the culture of microbes prior to the inoculation of VOC-degrading microbes). The bacteria may have played a predominant role in odor removal. The total average of the fungi in the biofilm was 9.64 × 106 CFU/g TS, which was only 6.40% of the control. The total average of the actinomycetes in the biofilm was 5.10 × 105 CFU/g TS, which was 5.63 times higher than that of the control. Findings from this study showed that usage of a biotrickling filter is a promising process for the treatment of complex odorous gas.  相似文献   

14.
In August and September 2005, Hurricanes Katrina and Rita caused breeches in the New Orleans, LA, levee system, resulting in catastrophic flooding. The city remained flooded for several weeks, leading to extraordinary mold growth in homes. To characterize the potential risks of mold exposures, we measured airborne molds and markers of molds and bacteria in New Orleans area homes. In October 2005, we collected air samples from 5 mildly water-damaged houses, 15 moderately to heavily water-damaged houses, and 11 outdoor locations. The air filters were analyzed for culturable fungi, spores, (1-->3,1-->6)-beta-D-glucans, and endotoxins. Culturable fungi were significantly higher in the moderately/heavily water-damaged houses (geometric mean=67,000 CFU/m3) than in the mildly water-damaged houses (geometric mean=3,700 CFU/m3) (P=0.02). The predominant molds found were Aspergillus niger, Penicillium spp., Trichoderma, and Paecilomyces. The indoor and outdoor geometric means for endotoxins were 22.3 endotoxin units (EU)/m3 and 10.5 EU/m3, respectively, and for (1-->3,1-->6)-beta-D-glucans were 1.7 microg/m3 and 0.9 microg/m3, respectively. In the moderately/heavily water-damaged houses, the geometric means were 31.3 EU/m3 for endotoxins and 1.8 microg/m3 for (1-->3,1-->6)-beta-D-glucans. Molds, endotoxins, and fungal glucans were detected in the environment after Hurricanes Katrina and Rita in New Orleans at concentrations that have been associated with health effects. The species and concentrations were different from those previously reported for non-water-damaged buildings in the southeastern United States.  相似文献   

15.
A quantitative and qualitative study was carried out of the atmospheric fungal propagules in two university buildings in the Campus of Anchieta (La Laguna, Tenerife, Canary Islands, Spain) and in the outdoor atmosphere, in order to ascertain the most abundant fungi and the concentration of spores in the air, as possible sources of respiratory allergies caused by this type of aeroallergens. Sampling was carried out using two kinds of traps (Burkard Personal Culture Sampler and Burkard Personal Slide Sampler), as well as adhesive tape. Sample 1, indoor, identified between 650-320 CFU m -3 depending on the culture medium, with outdoor values between 670-440 CFU m -3 ; sample 2, recorded between 630-80 CFU m -3 inside and 580-300 CFUm -3 in the outdoor atmosphere. The most represented genera were Cladosporium and Penicillium , although the following were also identified: Agaricales, Alternaria, Aspergillus, Botrytis, Drechslera, Coprinus, Curvularia, Chaetomium, Exserohilum, Fusarium, Helminthosporium, Leptosphaeria , Myxomycetes, Paecilomyces, Pleospora, Stemphylium, Tetraploa, Torula and Ulocladium .  相似文献   

16.
The concentration and distribution characteristics of airborne fungi were investigated in indoor and outdoor air of two metro stations (Imam Khomeini and Sadeghiyeh stations) in Tehran subway. Samples were taken from indoor air at each station from platform and ticket office area also from adjacent outdoor air of each station. Indoor sampling was conducted for two types of trains, old and new. The concentration of airborne fungi ranged from 21 CFU/m3 at the outdoor air of Imam Khomeini station to 1,402 CFU/m3 in the air samples collected from the platform of this station. Results showed that airborne fungi concentrations at indoor air were higher than the outdoor air (p < 0.05), and fungal levels significantly correlated with the number of passengers (p < 0.05; r = 0.68) and RH % (p < 0.05; r = 0.43). Sixteen genera of fungi were isolated in all sampled environments. The predominant genera identified in indoor and outdoor air were Penicillium spp. (34.88 % of total airborne fungi) and Alternaria spp. (29.33 % of total airborne fungi), respectively. The results of this study showed that the indoor air quality in subway is worse than the outdoor air.  相似文献   

17.
In order to study E. coli aerosol spreading from chicken houses to their surrounding air, air samples, including indoor and outdoor air (upwind 10 and 50 m as well as downwind 10, 50, 100, 200 and 400 m away) of 5 chicken houses were collected using six-stage Andersen microbial samplers and Reuter-Centrifugal samplers (RCS). E. coli concentrations (CFU/m3 air) collected from different sampling sites were calculated. E. coli strains from chicken feces samples were also isolated. Furthermore, the enterobacterial repetitive intergenic consensus (ERIC)-PCR method was applied to amplify the isolated E. coli strain DNA samples. Through the genetic similarity analyses of the E. coli obtained from different sampling sites, the spreading of bioaerosol from animal houses to the ambient air was characterized. The results showed that the isolated E. coli concentrations in indoor air (9―63 CFU/m3) in 5 chicken houses were higher than those in upwind and downwind air, but there were no significant differences between the indoor and downwind sites 10 m away from all the 5 houses (P>0.05). The phylogenetic tree indicated that a part of the E. coli (34.1%) isolated from indoor air had 100% similarity with those isolated from feces, and that most of E. coli isolated (54.5%) from downwind at 10, 50, 100 or even 200 m had 100% similarity with those isolated from indoor air or feces too. But those isolated from upwind air had a lower similarity (73%―92%) with corresponding strains isolated from indoor air or feces. Our results suggested that some strains isolated from downwind air and indoor air originated in the chicken feces, but most of isolates obtained from upwind air samples did not come from the chicken feces or indoor air. Effective hygienic measures should be taken in animal farms to prevent or minimize downwind spreading of microorganism aerosol.  相似文献   

18.

Aim of the Study

In many countries, Low Level Disinfection (LLD) of covered transvaginal ultrasound probes is recommended between patients'' examinations. The aim of this study was to evaluate the antimicrobial efficacy of LLD under routine conditions on a range of microorganisms.

Materials and Methods

Samples were taken over a six month period in a private French Radiology Center. 300 specimens derived from endovaginal ultrasound probes were analyzed after disinfection of the probe with wipes impregnated with a quaternary ammonium compound and chlorhexidine. Human papillomavirus (HPV) was sought in the first set of s100 samples, Chlamydia trachomatis and mycoplasmas were searched in the second set of 100 samples, bacteria and fungi in the third 100 set samples. HPV, C. trachomatis and mycoplasmas were detected by PCR amplification. PCR positive samples were subjected to a nuclease treatment before an additional PCR assay to assess the likely viable microorganisms. Bacteria and fungi were investigated by conventional methods.

Results

A substantial persistence of microorganisms was observed on the disinfected probes: HPV DNA was found on 13% of the samples and 7% in nuclease-resistant form. C. trachomatis DNA was detected on 20% of the probes by primary PCR but only 2% after nuclease treatment, while mycoplasma DNA was amplified in 8% and 4%, respectively. Commensal and/or environmental bacterial flora was present on 86% of the probes, occasionally in mixed culture, and at various levels (10->3000 CFU/probe); Staphylococcus aureus was cultured from 4% of the probes (10-560 CFU/probe). No fungi were isolated.

Conclusion

Our findings raise concerns about the efficacy of impregnated towels as a sole mean for disinfection of ultrasound probes. Although the ultrasound probes are used with disposable covers, our results highlight the potential risk of cross contamination between patients during ultrasound examination and emphasize the need for reviewing the disinfection procedure.  相似文献   

19.
Fungal agents are responsible for a variety of respiratory diseases both in humans and animals. The nature and seasonal variations of fungi have been investigated in many environments with wide ranging results. The aims of the present report were (i) to evaluate the quality and magnitude of exposure to airborne fungi in three differently structured equine stalls (open air, partially and completely enclosed buildings) during a one-year period, using an air sampling technique and (ii) to compare the distribution and frequency of fungal species, with regards to these different environments. Air samples were collected monthly from December 2001 to November 2002 by means of a surface air sampler (SAS) Super-90, (PBI International, Milan, Italy). Penicillium and Aspergillus spp. were cultured from all the stables in all seasons. Mucoraceae were also recovered in all seasons in stalls 1 and 2, while they were not isolated in spring and fall in stall 3. These fungi were detected in 28.4%, 72.9% and 60.5% of the total number of samples, respectively. Other fungal genera such as Alternaria, Cladosporium, Fusarium, Beauveria and Drechslera were also occasionally recovered.Viable fungal concentrations varied greatly, ranging from below the limit of detection to more than 3000 CFU/m3 for stables 1 and 2, and 1750 CFU/m3 for stable 3. The median fungal concentration was approximately 178 CFU/m3. Total fungal concentration appeared to be highest in summer, winter and spring, and lowest in the fall.  相似文献   

20.
The aim of this study was to estimate the indoor and outdoor concentrations of fungal spores in the Metropolitan Area of Sao Paulo (MASP), collected at different sites in winter/spring and summer seasons. The techniques adopted included cultivation (samples collected with impactors) and microscopic enumeration (samples collected with impingers). The overall results showed total concentrations of fungal spores as high as 36,000 per cubic meter, with a large proportion of non culturable spores (around 91% of the total). Penicillium sp. and Aspergillus sp. were the dominant species both indoors and outdoors, in all seasons tested, occurring in more than 30% of homes at very high concentrations of culturable airborne fungi [colony forming units(CFU) m−3]. There was no significant difference between indoor and outdoor concentrations. The total fungal spore concentration found in winter was 19% higher than that in summer. Heat and humidity were the main factors affecting fungal growth; however, a non-linear response to these factors was found. Thus, temperatures below 16°C and above 25°C caused a reduction in the concentration (CFU m−3) of airborne fungi, which fits with MASP climatalogy. The same pattern was observed for humidity, although not as clearly as with temperature given the usual high relative humidity (above 70%) in the study area. These results are relevant for public health interventions that aim to reduce respiratory morbidity among susceptible populations.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号