首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Background: The fracture between acrylic denture base material and artificial teeth is a common clinical occurrence in dental prosthodontic practice. Objective: To evaluate the bond strength between acrylic resins and resin denture teeth when submitted by two protocols of monomer liquid application on the tooth surface and using different polymerisation methods. Material and methods: Microwave‐polymerised (Onda‐Cryl), heat‐polymerised (Clássico) and autopolymerising (Jet) acrylic resins and a brand of resin denture teeth (Biotone) were used. The acrylic resins were polymerised according to the cycles: (A) microwave – fast cycle, Onda‐Cryl; (B) microwave – long cycle, Onda‐Cryl; (C) microwave – manufacturer’s cycle, Onda‐Cryl; (T) water bath – long cycle, Clássico and (Q) bench polymerisation cycle, Jet. Thirty specimens were prepared for each polymerisation method; 10 were packed with acrylic resin after 60 s of monomer liquid application on the tooth surface, 10 after 180 s and 10 without any monomer liquid application. For the purpose of the study, a shear test was used. anova and Tukey tests were performed to identify significant differences (α = 0.05). Results: The highest bond strength values were found for monomer surface treatments, regardless of the polymerisation cycles. The highest significant values were found for cycles B (15.4 ± 1.8 MPa), C (11.9 ± 4.9 MPa) and T (15.4 ± 2.6 MPa) for non‐treated and 60 s methylmethacrylate treated groups. Comparing the monomer liquid treatment, they did not differ significantly (p > 0.05), except for cycle A (p < 0.05). Conclusion: Chemical treatment using monomer on the tooth surface prior to the acrylic resin packing improved the bond strength between resin denture tooth and acrylic resin, regardless of monomer liquid treatment protocols. The microwavable resin, polymerised by fast cycle and autopolymerising resin should be avoided for processing denture and denture repairs, respectively.  相似文献   

2.
Objective: The purpose of this in vitro study was to evaluate the antimicrobial activity of acrylic resins containing different percentages of silver and zinc zeolite, and to assess whether the addition of zeolite alters the flexural and impact strength of the resins. Background: The characteristics of acrylic resins support microorganism development that can threaten the health of the dentures user. Material and methods: A microwave‐polymerised (Onda‐Cryl) and two heat‐polymerised (QC20 and Lucitone 550) acrylic resins were used. The materials were handled according to the manufacturers’ instructions. Fifty rectangular‐shaped specimens (8 × 10 × 4mm) were fabricated from each resin and assigned to 5 groups (n = 10) according to their percentage of Irgaguard B5000 silver–zinc zeolite (0%– control, 2.5%, 5.0%, 7.5% and 10%). Flexural strength and Izod impact strength were evaluated. The antimicrobial activity against two strains of Candida albicans and two strains of Streptococcus mutans was assessed by agar diffusion method. Data were analysed statistically by one‐way anova and Tukey’s test at 5% significance level. Results: The addition of 2.5% of Irgaguard B5000 to the materials resulted in antimicrobial activity against all strains. Flexural strength decreased significantly with the addition of 2.5% (QC20 and Lucitone 550) and 5.0% (Onda‐Cryl) of Irgaguard B5000. The impact strength decreased significantly with the addition of 2.5% (Lucitone 550) and 5.0% (QC20 and Onda‐Cryl) of zeolite. Conclusion: The addition of silver–zinc zeolite to acrylic resins yields antimicrobial activity, but may affect negatively the mechanical properties, depending on the percentage of zeolite.  相似文献   

3.
doi: 10.1111/j.1741‐2358.2011.00474.x
Effect of thermocycling on the flexural and impact strength of urethane‐based and high‐impact denture base resins Objective: Mechanical properties of the acrylic resins used for denture fabrication may be influenced by water and temperature. Thus, the aim of this study was to evaluate the effect of thermocycling on the flexural and impact strength of a high‐impact (Lucitone 199) and a urethane‐based denture material (Eclipse). Materials and methods: Flexural strength (64 × 10 × 3.3 mm) and impact strength (60 × 6 × 4 mm) specimens were made following the manufacturers’ instructions and assigned to two groups (n = 10): control (C) – not thermocycled – and T – thermocycled (5000 cycles between 5 and 55°C). Specimens were submitted to three‐point bending and Charpy impact tests. Results: Flexural strength (MPa) and impact strength (kJ/m2) data were analysed with two‐way anova (p = 0.05). The flexural strength of material Eclipse (C, 136.5; T, 130.7) was significantly higher than that of resin Lucitone 550 (C, 99.4; T, 90.1). Material Eclipse exhibited significantly higher impact strength (C, 6.9; T, 5.3) than the resin Lucitone 550 (C, 3.5; T, 3.0). For both materials, a significant decrease in flexural and impact strengths was observed when the specimens were thermocycled. Conclusion: Flexural and impact strengths were higher for Eclipse than for Lucitone 550, in both groups. Thermocycling decreased the flexural and impact strengths of Eclipse and Lucitone 550.  相似文献   

4.
Objective: The purpose of this study was to evaluate the effect of two post‐polymerisation treatments and different cycles of polymerisation on the cytotoxicity of two denture base resins. Materials and methods: The resins tested were Lucitone 550 and QC 20. Discs of resins were fabricated following the manufacturer's instructions. Lucitone 550 was processed by long cycle or short cycle. The resin QC 20 was processed by reverse cycle or normal cycle. The specimens were divided into groups: (i) post‐polymerised in microwave for 3 min at 500 W; (ii) post‐polymerised in water‐bath at 55°C for 60 min and (iii) without post‐polymerisation. Eluates were prepared by placing three discs into a sterile glass vial with 9 ml of Eagle's medium and incubated at 37°C for 24 hours. L929 cells were seeded into 96 well culture plates and DNA synthesis was assessed by 3H‐thymidine incorporation assay. Results: The results were submitted to two‐way anova and Tukey HSD test. QC 20 specimens polymerised by the normal cycle and submitted to microwave post‐polymerisation were graded as moderately cytotoxic. Similar results were observed for Lucitone 550 processed by long cycle without post‐polymerisation. The other experimental groups were graded as not cytotoxic. After water‐bath post‐polymerisation, specimens of Lucitone 550 processed by long cycle produced significantly lower inhibition of DNA synthesis than the other groups. Conclusion: The long cycle increased the cytotoxicity of Lucitone 550 and water‐bath post‐polymerisation reduced the cytotoxicity of Lucitone 550 processed by long cycle.  相似文献   

5.
doi: 10.1111/j.1741‐2358.2010.00435.x
Evaluation of Vickers hardness of different types of acrylic denture base resins with and without glass fibre reinforcement Objective: To evaluate the Vickers hardness of different acrylic resins for denture bases with and without the addition of glass fibres. Background: It has been suggested that different polymerisation methods, as well as the addition of glass fibre (FV) might improve the hardness of acrylic. Materials and methods: Five types of acrylic resin were tested: Vipi Wave (VW), microwave polymerisation; Vipi Flash (VF), auto‐polymerisation; Lucitone (LT), QC20 (QC) and Vipi Cril (VC), conventional heat‐polymerisation, all with or without glass fibre reinforcement (GFR) and distributed into 10 groups (n = 12). Specimens were then submitted to Vickers hardness testing with a 25‐g load for 30 s. All data were submitted to anova and Tukey’s HSD test. Results: A significant statistical difference was observed with regard to the polymerisation method and the GFR (p < 0.05). Without the GFR, the acrylic resin VC presented the highest hardness values, and VF and LT presented the lowest. In the presence of GFR, VC resin still presented the highest Vickers hardness values, and VF and QC presented the lowest. Conclusions: The acrylic resin VC and VW presented higher hardness values than VF and QC resins. Moreover, GFR increased the Vickers hardness of resins VW, VC and LT.  相似文献   

6.
doi: 10.1111/j.1741‐2358.2012.00676.x Effect of thermal cycling and disinfection on colour stability of denture base acrylic resin Objectives: The purpose of this study was to investigate the effect of thermal cycling and disinfection on the colour change of denture base acrylic resin. Materials and Methods: Four different brands of acrylic resins were evaluated (Onda Cryl, QC 20, Classico and Lucitone). All brands were divided into four groups (n = 7) determined according to the disinfection procedure (microwave, Efferdent, 4% chlorhexidine or 1% hypochlorite). The treatments were conducted three times a week for 60 days. All specimens were thermal cycled between 5 and 55°C with 30‐s dwell times for 1000 cycles before and after disinfection. The specimens’ colour was measured with a spectrophotometer using the CIE L*a*b* system. The evaluations were conducted at baseline (B), after first thermal cycling (T1), after disinfection (D) and after second thermal cycling (T2). Colour differences (ΔE) were calculated between T1 and B (T1B), D and B (DB), and T2 and B (T2B) time‐points. Results: The samples submitted to disinfection by microwave and Efferdent exhibited the highest values of colour change. There were significant differences on colour change between the time‐points, except for the Lucitone acrylic resin. Conclusions: The thermal cycling and disinfection procedures significantly affected the colour stability of the samples. However, all values obtained for the acrylic resins are within acceptable clinical parameters.  相似文献   

7.
doi: 10.1111/j.1741‐2358.2011.00582.x Effect of toothbrushing, chemical disinfection and thermocycling procedures on the surface microroughness of denture base acrylic resins Objective: This study verified the surface microroughness of denture acrylic resins submitted to toothbrushing, chemical disinfection and thermocycling procedures. Material and methods: Samples were prepared according to conventional, microwaved and boiled resins and submitted to microroughness measurements before and after procedures using a profilometer (Ra). Data were subjected to anova and Tukey’s test (5%). Results: Before thermocycling, a difference was found among treatments for microwaved and boiled resins, with greater values for toothbrushing and lower values for Efferdent and hypochlorite; control was intermediate. Differences among resins were observed for treatments, with higher values for boiled resin and lower values for conventional and microwaved resins. After thermocycling, differences were found for microwaved resin, with a higher value for toothbrushing and a lower value for Efferdent and hypochlorite; control was intermediate. Tooth‐brushed boiled resin presented higher values and hypochlorite lower values; control and Efferdent were intermediates. Differences among resins were seen for treatments, with higher values for boiled resin and lower values for conventional and microwaved resins. Boiled resin presented differences for toothbrushing and hypochlorite, before and after thermocycling procedures were compared. Conclusions: For microwaved and boiled resins, toothbrushing and chemical disinfection promoted different levels of surface microroughness when associated or not with thermocycling.  相似文献   

8.
doi: 10.1111/j.1741‐2358.2011.00520.x The effect of long‐term disinfection procedures on hardness property of resin denture teeth Objective: The aim of the study was to evaluate the effect of long‐term disinfection procedures on the Vickers hardness (VHN) of acrylic resin denture teeth. Material and methods: Five acrylic resin denture teeth (Vipi Dent Plus‐V, Trilux–T, Biolux‐B, Postaris‐P and Artiplus‐A) and one composite resin denture teeth (SR‐Orthosit‐O) were embedded in heat‐polymerised acrylic resin within polyvinylchloride tubes. Specimens were stored in distilled water at 37°C for 48 h. Measurements of hardness were taken after the following disinfection procedures: immersion for 7 days in 4% chlorhexidine gluconate or in 1% sodium hypochlorite (CIm and HIm group, respectively) and seven daily cycles of microwave sterilisation at 650 W for 6 min (MwS group). In the WIm group, specimens were maintained in water during the time used to perform the disinfection procedures (7 days). Data were analysed with anova followed by the Bonferroni procedure (α = 0.01). Results: Microwave disinfection decreased the hardness of all acrylic resin denture teeth (p < 0.001). Immersion for 7 days in 4% chlorhexidine gluconate or distilled water had significant effect on the hardness of the acrylic resin denture teeth A (p < 0.01), and 1% sodium hypochlorite on teeth T (p < 0.01). All disinfection procedures decrease the hardness of the composite resin denture teeth (p < 0.01). Teeth O exhibited the highest and teeth V the lowest hardness values in the control group (p < 0.01). Conclusions: Disinfection procedures changed the hardness of resin denture teeth.  相似文献   

9.
doi:10.1111/j.1741‐2358.2009.00307.x
Effect of flask closure method and post‐pressing time on the upper denture base adaptation Objectives: The purpose of this study was to evaluate the effect of flask‐closure methods, post‐pressing times and acrylic resins on denture base adaptation. Materials and methods: The resins were flasked using a hydraulic press and closed with the traditional clamp or RS system. Conventional heat‐cure resin was polymerised immediately or at 6 h post‐pressing at 74°C for 9 h. Rapid cycle heat‐cure resin was polymerised in boiling water for 20 min. After cooling, the bases were deflasked and the sets of cast‐base transversally sectioned in the regions distal to the canine, mesial to the first molar and in the posterior palatal zone. The adaptation was measured with an optical microscope (0.0005 mm) at five reference points for each section. Data were analysed using anova and Tukey’s test (α = 0.05). Results: Traditional clamp and immediate post‐pressing time improved base adaptation for conventional heat‐cure resin. Both post‐pressing times showed most accurate base adaptation for conventional heat‐cure resin when the traditional clamp was used. Immediate post‐pressing time improved base adaptation for conventional heat‐cure resin and the 6‐h delay in time was significant for the rapid cycle heat‐cure resin. Conclusions: Traditional clamp and immediate post‐pressing time improved base adaptation for conventional heat‐cure resin.  相似文献   

10.
Background: Microwave energy has proved to be an effective method for disinfecting acrylic dentures. However, the effect of microwave heating on the porosity of autopolymerising denture reline resins has not been investigated. Objective: The purpose of the study was to determine the effect of microwave disinfection on the porosity of autopolymerised denture reline materials (Kooliner‐K, New Truliner‐NT, Tokuso Rebase Fast‐TR and Ufi Gel Hard‐UGH) and a conventional heat‐polymerised denture base resin (Lucitone 550‐L). Material and methods: Specimens (10 mm × 20 mm × 1 mm) were obtained from the impression surface of the palatal mucosa in a single person and divided into four groups (n = 5). The porosity was evaluated after polymerisation (C1), after two cycles of microwave disinfection (MW2), after seven cycles of microwave disinfection (MW7) and after 7 days storage in water at 37°C (C2). Specimens from group MW7 were exposed to microwave disinfection daily being stored in water at 37°C between exposures. All the replicas were sputter coated with gold and micrographs/digital images were taken of each replica using scanning electron microscopy at magnification × 100. The SEM micrographs were then examined using an image analyser to determine the number of pores. Comparison between materials and groups were made using Kruskal–Wallis tests. Results: MW7 resulted in a significant increase in the number from the pores of material K, but decreased in number in reline material TR and UGH reline resin. The number of pores in materials NT and L remained unaffected following microwave disinfection. Conclusion: Differences in the porosity amongst the materials and for different experimental conditions were observed following microwave disinfection.  相似文献   

11.
doi:10.1111/j.1741‐2358.2009.00336.x
Effect of the physical properties of acrylic resin of overnight immersion in sodium hypochlorite solution Objectives: This study evaluated colour stability, surface roughness and flexural strength of microwave‐polymerised acrylic resin after overnight immersion in sodium hypochlorite, simulating 180 days use. Materials and methods: Forty disc‐shaped (15 mm × 4 mm) and 40 rectangular specimens (65 mm × 10 mm × 3 mm) were prepared from microwave‐polymerised acrylic resin. The specimens were immersed in 0.5, 1% sodium hypochlorite, Clorox/Calgon and distilled water. Colour measurements (ΔE) were determined by a portable colorimeter. A surface analyser was used to measure roughness (μm). The flexural strength (MPa) was measured using a three‐point bending test in a universal testing machine. Data were evaluated by one‐way anova , followed by Student–Newman–Keuls test (α = 0.05). Results: Statistical analysis found significantly higher colour changes (SNK, p < 0.001) for the 1% sodium hypochlorite, but mean ΔE value quantified by National Bureau of Standards was classified as slight. When comparing the surface roughness, no statistical significance was found among the solutions (anova , p = 0.637). The 1% sodium hypochlorite presented significantly lower flexural strength compared with the control group (SNK, p = 0.034). Conclusion: It was concluded that immersion in 1% sodium hypochlorite solutions for 8 h does influence the colour stability and flexural strength of microwave‐polymerised acrylic resin, during the simulated period of 180 days.  相似文献   

12.
doi:10.1111/j.1741‐2358.2009.00321.x
Flexural properties of repaired heat‐polymerising acrylic resin after wetting with monomer and acetone Objectives: Repair strength can be improved by treating fractured surfaces of a denture. Background: This study investigated flexural properties of heat‐polymerised acrylic resin specimens repaired with auto‐polymerising and visible light curing (VLC) resins after the repair surfaces were wetted with monomers or acetone. Materials and Methods: Fifty‐four specimens (65 × 10 × 2.5 mm) were prepared and 48 of them were sectioned to simulate denture fracture. Butt‐joint designed repair surfaces were wetted with heat‐, auto‐polymerising monomers and acetone for 180 s and repaired with auto‐polymerising and VLC resins. After repairs, specimens were subjected to three‐point bending test and flexural strength, strain, fracture load, modulus of elasticity and deflection values were recorded. Data were analysed with Student t and LSD tests (p ≤ 0.05). Results: Overall flexural strength, strain, fracture load and deflection values of specimens repaired with VLC resin were significantly higher than the specimens repaired with auto‐polymerising resin for all types of wetting agent (p < 0.05). Within the wetting agents, heat‐ and auto‐polymerising monomers produced the best mechanical properties, while wetting with acetone did not provide superior effect over both monomers. Conclusion: In clinical use, wetting the repair surfaces may result in stronger repairs. The use of bonding agent in VLC resin repairs in combination with wetting agent results in improved flexural properties.  相似文献   

13.
Takahashi Y  Yoshida K  Shimizu H 《Gerodontology》2012,29(2):e1086-e1091
doi: 10.1111/j.1741‐2358.2012.00616.x Fracture resistance of maxillary complete dentures subjected to long‐term water immersion Objective: This study investigated the fracture resistance of maxillary acrylic resin complete dentures subjected to long‐term water immersion. Materials and Methods: Maxillary acrylic resin complete dentures were fabricated from five denture base resins. Half of the dentures were stored in water for 50 h, and the other half were kept in water for 180 days before testing. Ten specimens were fabricated per group. The flexural load at the proportional limit (FL‐PL) of the dentures was tested. Results: A two‐way anova revealed a significant difference in FL‐PL because of the denture base material variable. There were no significant differences in FL‐PL because of the effect of water immersion and the interaction between the effect of water immersion and the denture base material. The FL‐PLs of the dentures fabricated with the two conventional heat‐processed resins, the pour‐type autopolymerizing resin and the microwave energy‐processed resin were not significantly different from each other; they were significantly higher than the light‐activated resin in regard to their FL‐PL. Conclusion: The FL‐PLs of the maxillary acrylic resin complete dentures did not change after long‐tern water immersion, and the FL‐PL of the denture fabricated from the light‐activated resin was lower than those of the other materials.  相似文献   

14.
doi: 10.1111/j.1741‐2358.2011.00454.x Influence of surface treatments on the flexural strength of denture base repair Objective: The purpose of this study was to evaluate the flexural strength of repairs made with autopolymerising acrylic resin after different treatments of joint surfaces. Material and Methods: Fifty rectangular specimens were made with heat‐polymerised acrylic resin and 40 were repaired with autopolymerising acrylic resin following joint surface treatments: group 1 (intact specimens), group 2 (chemical treatment: wetting with methyl‐methacrylate for 180 s), group 3 (abraded with silicon carbide paper), group 4 (abraded and wetting with methyl‐methacrylate for 180 s) and group 5 (without surface treatment). The flexural strength was measured by a three‐point bending test using a universal testing machine with a 100 Kgf load cell in the centre of repair at 5 mm/min cross‐head speed. All data were analysed using one‐way anova and Tukey HSD test for multiple comparisons (p < 0.05). Results: Among repaired specimens, groups 2 and 4 had 66.53 ± 3.4 and 69.38 ± 1.8 MPa mean values and were similar. These groups had superior flexural strength than groups 3 and 5 that were similar and had 54.11 ± 3.4 and 51.24 ± 2.8 MPa mean values, respectively. Group 1 had a mean value of 108.30 ± 2.8 MPa being the highest result. Conclusion: It can be concluded that the treatment of the joint surfaces with methyl‐methacrylate increases the flexural strength of denture base repairs, although the strength is still lower than that observed for the intact denture base resin. Abrasion with sandpaper was not able to influence the flexural strength of repaired denture bases.  相似文献   

15.
doi: 10.1111/j.1741‐2358.2011.00515.x Flexural and bond strengths of relined denture polymers assessed by four‐point bending tests and Weibull analysis Objectives: The aim of this study was to (1) investigate the flexural strengths of three denture resins i.e. heat, photopolymerised and microwaved and how it was affected by relining with auto‐ and visible light–polymerised hard reliners, (2) investigate the bond strengths between denture resins and hard reliners and (3) interpret the results of both tests by utilising Weibull analysis. Materials and methods: Specimens (65 × 10 × 2.5 mm) from denture resins, relined and bonded combinations were tested using a four‐point bending test in a universal testing machine and a crosshead speed of 5 mm/min. Ten specimens for each bulk resin and denture resin–reliner combination for a total of 150 were tested. Results: Statistical analysis indicated significant differences between bulk materials (p < 0.001) and between reliners (p < 0.001) for flexural and bond strength tests. Conclusion: It was concluded that (1) the four‐point flexural strength was different between the denture base materials, (2) flexure strength between bulk and relined or between relined with autopolymerised and photopolymerised bases was different, (3) flexural strength among relined denture bases was different and (4) bond strengths among relined denture bases were different.  相似文献   

16.
Background: Denture base acrylic resin is easily colonised by oral endogenous bacteria and Candida spp., and eventually by extra‐oral species such as Staphylococcus spp., Pseudomonadaceae or members of Enterobacteriaceae. This microbial reservoir can be responsive for denture related stomatitis and aspiration pneumonia, a life‐threatening infection especially in geriatric patients. However, the oral and denture hygiene of dependant elderly individuals is extremely poor. Objective: This in vitro study aimed to determine the per cent of a quaternary ammonium compound heat‐polymerised in acrylic resin necessary to obtain denture base displaying antiseptic properties. Design: Acrylic resin discs containing 2–50% ammonium polymer (Poly 202063A; 0% control) were soaked in artificial saliva for 4 weeks. Resin discs were incubated for 24 hours with Escherichia coli, Staphylococcus aureus, Pseudomonas aeruginosa [37°C, brain–heart infusion (BHI) broth and phosphate‐buffered saline (PBS) buffer] and Candida albicans (30°C, Schaedler broth), in 15 ml (168 discs) and 600 μl (168 discs) of inoculum. Microbial growth was verified at t 0 hours and t 24 hours. Data were recorded as the mean of three colony forming unit (CFU) numerations. The borderline of antimicrobial effect was determined at 0.1% viable cells. Results: In 600 μl of PBS inoculum, resin specimens had a bactericidal effect (E. coli and S. aureus: 2%; P. aeruginosa: 10%) and a fungicidal effect (C. albicans: 50%). Long‐term stability and toxicity in vivo studies are now required. Conclusion: A 2% quaternary ammonium compound polymerised with a denture acrylic resin displayed antiseptic properties after a 4‐week soaking period in artificial saliva. Such antiseptic denture base could help geriatric patients to improve their oral health.  相似文献   

17.
doi: 10.1111/j.1741‐2358.2012.00657.x The effect of immersion cleansers on gloss, colour and sorption of acetal denture base material Objective: To study the effect of peroxide and hypochlorite cleansers on gloss, colour and sorption of acetal denture resins. Materials and methods: Pink acetal and thermoplastic acrylic resins were evaluated. Thirty‐five specimens 39 × 39 × 1.8 mm of each resin were prepared. Each group of specimens (n = 7) was then immersed into cleansers for 100 days. Group I immersed in tap water, Group II in Corega Extradent for 5 min, Group III in Corega Extradent for 8 h, Group IV in NitrAdine? Seniors for 15 min and Group V in NaOCl 5.25%. Gloss, colour and weight measurements were taken initially and after 100 days. Data subjected to two‐way anova and Tukey’s test at α = 0.05. Results: Acrylic resin showed reductions of glossiness from ?5 to ?15 and acetal from ?0.2 to ?6. Colour changes (ΔΕ*) ranged from 2.64 to 7.64 for acrylic and 2.77 to 26.54 for acetal resin. Sorption for acrylic ranged from 11.64 to 17.06 μg/mm3 and 9.18 to 24.79 μg/mm3 for acetal resin. The results of (ΔΕ*) and sorption showed an interaction between denture resins and cleansers. Conclusions: The gloss of acetal resin was less affected by water, peroxides and NaOCl 5.25% compared with acrylic resin. Acetal resin showed clinically acceptable (ΔΕ*) whereas acrylic resin unacceptable ones for water and peroxide solutions. The immersion of acetal resin in NaOCl 5.25% showed clinically unacceptable (ΔΕ*) and higher sorption and should be avoided or should be managed with care.  相似文献   

18.
doi: 10.1111/j.1741‐2358.2011.00516.x Effect of repeated microwave disinfections on bonding of different commercial teeth to resin denture base Objective: To verify the influence of repeated microwave disinfections on the shear bond strength of two commercial types of teeth to acrylic resin, when the ridge lap surfaces were unmodified, bur abraded, bur grooved or etched by monomer. Material and methods: Eighty specimens (n = 10) were adhered to the tooth ridge lap surface, polymerised in a water bath at 74°C for 9 h. Microwaved specimens were individually immersed in 150 ml of water and submitted to five simulated disinfections in a microwave oven calibrated at 650 W for 3 min. Control specimens were not microwave treated. Shear bond strength tests were performed in an Instron machine with a cross‐speed of 1 mm/min. The fracture load values were transformed into shear bond strength as a function of the bonding area (0.28 cm2). Data were submitted to anova and Tukey’s test (α = 0.05). Fractured areas were classified as adhesive, cohesive (resin or tooth) or mixed failures. Results: Repeated microwave disinfections increased the shear strength of the tooth/resin bond. Mechanical retention in microwaved and non‐microwaved procedures improved the shear bond strength. Conclusions: The different commercial types of teeth influenced shear bond strength values, with Biotone teeth showing the lower values.  相似文献   

19.
doi: 10.1111/j.1741‐2358.2011.00573.x
Effect of long‐term water immersion on the fracture toughness of denture base and reline resins purpose: This study evaluated the fracture toughness (FT) of one denture base (Lucitone 550 – L) and four hard reline resins [Ufi Gel Hard (UH), Tokuyama Rebase II (TR), New Truliner (NT) and Kooliner (K)], and the effect of long‐term water storage on this property. Materials and methods: Forty specimens (40 × 8 × 4 mm) of each material were made, and FT was assessed after polymerisation (control of reliners), after 48 ± 2 h in water at 37°C (control of denture base resin) and after storage in water at 37°C for 7, 90 or 180 days (all materials). Data (MPa.m1/2) were analysed by two‐way anova and Games–Howell test (p = 0.05). Results: Resin L exhibited the highest FT mean values. After 180 days of storage, FT mean values of L (3.37), UH (1.53) and K (1.20) were higher than those of the other periods. FT mean values of NT decreased from control (1.63) to 7 days (1.30) and then remained constant. FT mean values of TR (1.13) were similar in all periods of analysis. Conclusion: The denture base resin L showed higher FT mean values than the reline resins. Long‐term water storage increased the FT of L, UH and K, reduced the FT of NT and did not influence the FT of TR.  相似文献   

20.
doi:10.1111/j.1741‐2358.2009.00292.x
Effect of reline material and denture base surface treatment on the impact strength of a denture base acrylic resin Objective: In this study, the effect of relining and surface treatment on the impact strength (IS) of a heat‐polymerising denture base acrylic resin (Lucitone 550‐L) was evaluated. Materials and methods: Rectangular bars of L were made (60 × 6 × 2 mm) and relined (2 mm) with the relining resins Ufi Gel Hard (UH) and Tokuso Rebase Fast (TR). Specimens relined with L and intact L, TR and UH specimens were also made (60 × 6 × 4 mm), for comparison. Before relining, the L surface was left untreated or wetted with methyl methacrylate monomer and/or the bonding agents (BA) supplied by manufacturers of the reline resins. V‐notches were machined at the midpoint of the length of all specimens. The notches were made either across the width (Nw) or across the thickness of the specimens (Nth). The Charpy impact test was performed using a 0.5‐J pendulum, which had been specially designed and constructed. Data were analysed separately for each notch position using one‐way analysis of variance and Tukey honestly significant difference posthoc test (p = 0.05). Results: The IS of L was similar to that of L/L. For the Nw notch, treating the denture base L with TR BA and relining with TR reline material produced the highest IS. Conclusion: The IS of specimens made from heat polymerising acrylic resin Lucitone 550 was increased after relining using the hard chairside reline resin TR with its proprietary BA.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号