首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.

Objective

“Patient-prosthesis mismatch” (PPM) after aortic valve replacement (AVR) has been reported to increase morbidity and mortality. Although algorithms have been developed to avoid PPM, factors favouring its occurrence have not been well defined.

Design and Setting

This was a prospective cohort study performed at the Medical University of Vienna.

Patients

361 consecutive patients who underwent aortic valve replacement for isolated severe aortic stenosis were enrolled.

Main Outcome Measures

Patient- as well as prosthesis-related factors determining the occurrence of moderate and severe PPM (defined as effective orifice area indexed to body surface area ≤ 0.8 cm2/m2) were studied.

Results

Postoperatively, 172 patients (48%) were diagnosed with PPM. The fact that predominantly female patients were affected (58% with PPM diagnosis in women versus 36% in men, p<0.001) was explained by the finding that they had smaller aortic root diameters (30.5±4.7 mm versus 35.3±4.2 mm, p<0.0001) and a higher proportion of bioprosthetic valves (82% versus 62%, p<0.0001), both independent predictors of PPM (aortic root diameter: OR 0.009 [95% CI, 0.004;0.013]; p = 0.0003, presence of bioprosthetic valve: OR 0.126 [95% CI, 0.078;0.175]; p<0.0001).

Conclusions

The occurrence of PPM is determined by aortic root diameter and prosthesis type. Novel sutureless bioprostheses with optimized hemodynamic performance or transcatheter aortic valves may become a promising alternative to conventional bioprosthetic valves in the future.  相似文献   

2.

Background

Failure of bioprosthetics is usually caused by calcification of the leaflets as a consequence of high tensile stresses. The stentless valve resembles native mitral valve anatomy, has a flexible leaflet attachment and a suspension at the papillary muscles, and preserves annuloventricular continuity. In this study, the effects of the stentless valve design on leaflet stress were investigated with a finite element model.

Methods

Finite element models of the stentless quadrileaflet mitral valve were created in the close and open configurations. The geometry of the stented trileaflet mitral valve was also analyzed for comparative purposes. Under the designated pressures, the regional stresses were evaluated, and the distributions of stresses were assessed.

Results

Regardless of whether the valve is in the open or close configuration, the maximum first principal stress was significantly lower in the stentless valve than in the stented valve. For the stentless valves, limited stress concentration was discretely distributed in the papillary flaps under both close and open conditions. In contrast, in the stented valve, increased stress concentration was evident at the central belly under the open condition and at the commissural attachment under close condition. In either configuration, the maximum second principal stress was markedly lower in the stentless valve than in the stented valve.

Conclusions

The stentless valve was associated with a significant reduction in leaflet stress and a more homogeneous stress distribution compared to the stented valve. These findings are consistent with recent reports of the clinical effectiveness of the stentless quadrileaflet mitral valve.  相似文献   

3.

Purpose

To conduct high-resolution imaging of the retinal nerve fiber layer (RNFL) in normal eyes using adaptive optics scanning laser ophthalmoscopy (AO-SLO).

Methods

AO-SLO images were obtained in 20 normal eyes at multiple locations in the posterior polar area and a circular path with a 3–4-mm diameter around the optic disc. For each eye, images focused on the RNFL were recorded and a montage of AO-SLO images was created.

Results

AO-SLO images for all eyes showed many hyperreflective bundles in the RNFL. Hyperreflective bundles above or below the fovea were seen in an arch from the temporal periphery on either side of a horizontal dividing line to the optic disc. The dark lines among the hyperreflective bundles were narrower around the optic disc compared with those in the temporal raphe. The hyperreflective bundles corresponded with the direction of the striations on SLO red-free images. The resolution and contrast of the bundles were much higher in AO-SLO images than in red-free fundus photography or SLO red-free images. The mean hyperreflective bundle width around the optic disc had a double-humped shape; the bundles at the temporal and nasal sides of the optic disc were narrower than those above and below the optic disc (P<0.001). RNFL thickness obtained by optical coherence tomography correlated with the hyperreflective bundle widths on AO-SLO (P<0.001)

Conclusions

AO-SLO revealed hyperreflective bundles and dark lines in the RNFL, believed to be retinal nerve fiber bundles and Müller cell septa. The widths of the nerve fiber bundles appear to be proportional to the RNFL thickness at equivalent distances from the optic disc.  相似文献   

4.

Background

The clinical course of bicuspid aortic valves (BAVs) is variable. Data on predictors of aortopathy and valvular dysfunction mainly focus on valve morphology.

Aim

To determine whether the presence and extent of the raphe (fusion site of valve leaflets) is associated with the degree of aortopathy and valvular dysfunction in patients with isolated BAV and associated aortic coarctation (CoA).

Methods

Valve morphology and aortic dimensions of 255 BAV patients were evaluated retrospectively by echocardiography.

Results

BAVs with a complete raphe had a significantly higher prevalence of valve dysfunction (especially aortic regurgitation) than BAVs with incomplete raphes (82.9 vs. 66.7 %, p = 0.01). Type 1A BAVs (fusion of right and left coronary leaflets) and complete raphe had larger aortic sinus diameters compared with the rest of the population (37.74 vs. 36.01, p = 0.031). Patients with CoA and type 1A BAV had significantly less valve regurgitation (13.6 vs. 55.8 %, p < 0.001) and smaller diameters of the ascending aorta (33.7 vs. 37.8 mm, p < 0.001) and aortic arch (25.8 vs. 30.2 mm, p < 0.001) than patients with isolated BAV.

Conclusions

Type 1A BAV with complete raphe is associated with more aortic regurgitation and root dilatation. The majority of CoA patients have incomplete raphes, associated with smaller aortic root diameters and less valve regurgitation.  相似文献   

5.

Background

Reduced N-acetyl-aspartate (NAA) levels in magnetic resonance spectroscopy (MRS) may visualize axonal damage even in the normal appearing white matter (NAWM). Demyelination and axonal degeneration are a hallmark in multiple sclerosis (MS).

Objective

To define the extent of axonal degeneration in the NAWM in the remote from focal lesions in patients with relapsing-remitting (RRMS) and secondary progressive MS (SPMS).

Material and Methods

37 patients with clinical definite MS (27 with RRMS, 10 with SPMS) and 8 controls were included. We used 2D 1H-MR-chemical shift imaging (TR = 1500ms, TE = 135ms, nominal resolution 1ccm) operating at 3Tesla to assess the metabolic pattern in the fronto–parietal NAWM. Ratios of NAA to creatine (Cr) and choline (Cho) and absolute concentrations of the metabolites in the NAWM were measured in each voxel matching exclusively white matter on the anatomical T2 weighted MR images.

Results

No significant difference of absolute concentrations for NAA, Cr and Cho or metabolite ratios were found between RRMS and controls. In SPMS, the NAA/Cr ratio and absolute concentrations for NAA and Cr were significantly reduced compared to RRMS and to controls.

Conclusions

In our study SPMS patients, but not RRMS patients were characterized by low NAA levels. Reduced NAA-levels in the NAWM of patients with MS is a feature of progression.  相似文献   

6.

Objective

Variations of conductive fluid content in brain tissue (e.g. cerebral edema) change tissue impedance and can potentially be measured by Electrical Impedance Tomography (EIT), an emerging medical imaging technique. The objective of this work is to establish the feasibility of using EIT as an imaging tool for monitoring brain fluid content.

Design

a prospective study.

Setting

In this study EIT was used, for the first time, to monitor variations in cerebral fluid content in a clinical model with patients undergoing clinical dehydration treatment. The EIT system was developed in house and its imaging sensitivity and spatial resolution were evaluated on a saline-filled tank.

Patients

23 patients with brain edema.

Interventions

The patients were continuously imaged by EIT for two hours after initiation of dehydration treatment using 0.5 g/kg intravenous infusion of mannitol for 20 minutes.

Measurement and Main Results

Overall impedance across the brain increased significantly before and after mannitol dehydration treatment (p = 0.0027). Of the all 23 patients, 14 showed high-level impedance increase and maintained this around 4 hours after the dehydration treatment whereas the other 9 also showed great impedance gain during the treatment but it gradually decreased after the treatment. Further analysis of the regions of interest in the EIT images revealed that diseased regions, identified on corresponding CT images, showed significantly less impedance changes than normal regions during the monitoring period, indicating variations in different patients'' responses to such treatment.

Conclusions

EIT shows potential promise as an imaging tool for real-time and non-invasive monitoring of brain edema patients.  相似文献   

7.

Background

Mechanical ventilation (MV) induces diaphragmatic muscle fiber atrophy and contractile dysfunction (ventilator induced diaphragmatic dysfunction, VIDD). It is unknown how rapidly diaphragm muscle recovers from VIDD once spontaneous breathing is restored. We hypothesized that following extubation, the return to voluntary breathing would restore diaphragm muscle fiber size and contractile function using an established rodent model.

Methods

Following 12 hours of MV, animals were either euthanized or, after full wake up, extubated and returned to voluntary breathing for 12 hours or 24 hours. Acutely euthanized animals served as controls (each n = 8/group). Diaphragmatic contractility, fiber size, protease activation, and biomarkers of oxidative damage in the diaphragm were assessed.

Results

12 hours of MV induced VIDD. Compared to controls diaphragm contractility remained significantly depressed at 12 h after extubation but rebounded at 24 h to near control levels. Diaphragmatic levels of oxidized proteins were significantly elevated after MV (p = 0.002) and normalized at 24 hours after extubation.

Conclusions

These findings indicate that diaphragm recovery from VIDD, as indexed by fiber size and contractile properties, returns to near control levels within 24 hours after returning to spontaneous breathing. Besides the down-regulation of proteolytic pathways and oxidative stress at 24 hours after extubation further repairing mechanisms have to be determined.  相似文献   

8.

Background

Patients with diabetes mellitus show a negative outcome in percutaneous coronary intervention, aortic valve replacement and cardiac surgery. The impact of diabetes on patients undergoing treatment of severe mitral regurgitation (MR) using the MitraClip system is not known. We therefore sought to assess whether percutaneous mitral valve repair with the MitraClip system is safe and effective in patients with diabetes mellitus.

Methods and Results

We included 58 patients with severe and moderate-to-severe MR in an open-label observational single-center study. Ninteen patients were under oral medication or insulin therapy for type II diabetes mellitus. MitraClip devices were successfully implanted in all patients with diabetes and in 97.4% (n = 38) of patients without diabetes (p = 0.672). Periprocedural major cardiac adverse and cerebrovascular events (MACCE) occurred in 5.1% (n = 2) of patients without diabetes whereas patients with diabetes did not show any MACCE (p = 0.448). 30-day mortality was 1.7% (n = 1) with no case of death in the diabetes group. Short-term follow up of three months showed a significant improvement of NYHA class and quality of life evaluated by the Minnesota Living with Heart Failure Questionnaire in both groups, with no changes in the 6-minute walk test.

Conclusions

Mitral valve repair with the MitraClip system is safe and effective in patients with type II diabetes mellitus.

Trial Registration

MitraClip Registry NCT02033811  相似文献   

9.

Introduction

C-peptide and insulin measurements in blood provide useful information regarding endogenous insulin secretion. Conflicting evidence on sample stability and handling procedures continue to limit the widespread clinical use of these tests. We assessed the factors that altered the stability of insulin and C-peptide in blood.

Methods

We investigated the impact of preservative type, time to centrifugation, storage conditions and duration of storage on the stability of C-peptide and insulin on three different analytical platforms.

Results

C-peptide was stable for at least 24 hours at room temperature in both centrifuged and whole blood collected in K+-EDTA and serum gel tubes, with the exception of whole blood serum gel, which decreased to 78% of baseline at 24 hours, (p = 0.008). Insulin was stable at room temperature for 24 hours in both centrifuged and whole blood collected in K+-EDTA tubes. In contrast insulin levels decreased in serum gel tubes both centrifuged and whole blood (66% of baseline, p = 0.01 and 76% of baseline p = 0.01, by 24 hours respectively). C-peptide and insulin remained stable after 6 freeze-thaw cycles.

Conclusions

The stability of C-peptide and insulin in whole blood K+-EDTA tubes negates the need to conform to strict sample handling procedures for these assays, greatly increasing their clinical utility.  相似文献   

10.

Background

Autosomal dominant spinocerebellar ataxia type 1 is an adult onset progressive disorder with well characterized neurodegeneration in the cerebellum and brainstem. Beyond brain atrophy, few data exist concerning retinal and optic nerve involvement.

Objective

To evaluate retinal changes in SCA1 patients compared to age and gender matched healthy controls.

Methodology/Principal Findings

Nine patients with SCA1 were prospectively recruited from the ataxia clinic and were compared to nine age and gender matched healthy controls. Both cohorts received assessment of visually evoked potentials and eye examination by optical coherence tomography to determine retinal nerve fiber layer thickness and total macular volume. While no differences were found in visually evoked potentials, SCA1 patients showed a significant reduction of mean retinal nerve fiber layer thickness (RNFLT) compared to healthy controls (84±13 µm vs. 97±8 µm, p = 0.004). Temporal areas showed the most prominent RNFLT reduction with high statistical significances (temporal-inferior: p<0.001, temporal: p<0.001, temporal-superior: p = 0.005) whereas RNFLT in nasal areas was in the range of the control group. From six SCA1 patients an additional macular scan was obtained. The comparison to the corresponding healthy control showed a slight but not significant reduction in TMV (8.22±0.68 mm3 vs. 8.61±0.41 mm3, p = 0.15).

Conclusion

In SCA1 patients, we found evidence for degeneration of retinal nerve fibers. The temporal focus of the observed retinal nerve fiber layer reduction suggests an involvement of the papillo-macular bundle which resembles pathology found in toxic or mitochondrial optic nerve disease such as Leber''s hereditary optic neuropathy (LHON) or dominant optic atrophy (DOA).  相似文献   

11.

Background

Mechanistic hypotheses suggest a potential effect of dietary fiber on breast carcinogenesis through the modulation of insulin-like growth factor bioactivity, estrogen metabolism and inflammation. An association between dietary fiber intake and breast cancer risk has been suggested in epidemiological studies but remains inconclusive. In particular, data is lacking regarding the different types of dietary fibers.

Objective

The objective was to investigate the prospective relationship between dietary fiber intake and breast cancer risk, taking into account different types of dietary fiber (overall, insoluble, soluble and from different food sources: cereals, vegetables, fruits and legumes).

Design

4684 women from the SU.VI.MAX cohort were included in this analysis as they completed at least three 24h-dietary records within the first two years of follow-up. Among them, 167 incident invasive breast cancers were diagnosed during a median follow-up of 12.6 years (between 1994 and 2007). The associations between quartiles of dietary fiber intake and breast cancer risk were characterized using multivariate Cox proportional hazards models.

Results

Total fiber intake was not associated with breast cancer risk (HRQuartile4vs.Quartile1 = 1.29 (95%CI 0.66–2.50), P-trend = 0.5), nor was fiber intake from cereals (P-trend = 0.1), fruits (P-trend = 0.9) and legumes (P-trend = 0.3). In contrast, vegetable fiber intake was related to a decreased risk of breast cancer (HRQ4vs.Q1 = 0.50 (0.29-0.88), P-trend = 0.03). Overall vegetable intake (in g/day) was not associated with breast cancer risk (P-trend = 0.2).

Conclusion

This prospective study suggests that vegetable fiber intake may contribute to reduce breast cancer risk, in line with experimental mechanistic data.  相似文献   

12.

Background

The blood based interferon-gamma release assays (IGRA) for the diagnosis of tuberculosis do not discriminate between active TB disease and latent TB infection (LTBI). The search for distinguishing biomarkers therefore continues, as the accurate diagnosis of tuberculosis is particularly challenging in children. IFN-γ-inducible protein 10 (IP-10/CXCL10) has recently been evaluated as a marker for active TB in adults with promising results.

Aim

To investigate this new biomarker for active TB and LTBI in paediatrics.

Method

We measured IP-10 levels using ELISA in supernatants of whole blood samples stimulated with TB-specific-antigens and negative control antigen.

Results

IP-10 is produced in high levels following mycobacterial antigen stimulation in active TB (n = 17) and LTBI (n = 16) compared to controls (n = 16) and to IFN-γ. The baseline levels of IP-10 are increased in active TB and in LTBI, but there is no significant difference of stimulated levels of IP-10 between active TB and LTBI.

Conclusions

IP-10 is a biomarker for tuberculosis in children. However like IFNγ, IP-10 also does not distinguish between active TB and LTBI.  相似文献   

13.

Purpose

To enable high spatial and temporal breast imaging resolution via combined use of high field MRI, array coils, and forced current excitation (FCE) multi channel transmit.

Materials and Methods

A unilateral 16-channel receive array insert was designed for use in a transmit volume coil optimized for quadrature operation with dual-transmit RF shimming at 7T. Signal-to-noise ratio (SNR) maps, g-factor maps, and high spatial and temporal resolution in vivo images were acquired to demonstrate the utility of the coil architecture.

Results

The dual-transmit FCE coil provided homogeneous excitation and the array provided an increase in average SNR of 3.3 times (max 10.8, min 1.5) compared to the volume coil in transmit/receive mode. High resolution accelerated in vivo breast imaging demonstrated the ability to achieve isotropic spatial resolution of 0.5 mm within clinically relevant 90 s scan times, as well as the ability to perform 1.0 mm isotropic resolution imaging, 7 s per dynamics, with the use of bidirectional SENSE acceleration of up to R = 9.

Conclusion

The FCE design of the transmit coil easily accommodates the addition of a sixteen channel array coil. The improved spatial and temporal resolution provided by the high-field array coil with FCE dual-channel transmit will ultimately be beneficial in lesion detection and characterization.  相似文献   

14.

Rationale

Sutezolid (PNU-100480) is a linezolid analog with superior bactericidal activity against Mycobacterium tuberculosis in the hollow fiber, whole blood and mouse models. Like linezolid, it is unaffected by mutations conferring resistance to standard TB drugs. This study of sutezolid is its first in tuberculosis patients.

Methods

Sputum smear positive tuberculosis patients were randomly assigned to sutezolid 600 mg BID (N = 25) or 1200 mg QD (N = 25), or standard 4-drug therapy (N = 9) for the first 14 days of treatment. Effects on mycobacterial burden in sputum (early bactericidal activity or EBA) were monitored as colony counts on agar and time to positivity in automated liquid culture. Bactericidal activity was also measured in ex vivo whole blood cultures (whole blood bactericidal activity or WBA) inoculated with M. tuberculosis H37Rv.

Results

All patients completed assigned treatments and began subsequent standard TB treatment according to protocol. The 90% confidence intervals (CI) for bactericidal activity in sputum over the 14 day interval excluded zero for all treatments and both monitoring methods, as did those for cumulative WBA. There were no treatment-related serious adverse events, premature discontinuations, or dose reductions due to laboratory abnormalities. There was no effect on the QT interval. Seven sutezolid-treated patients (14%) had transient, asymptomatic ALT elevations to 173±34 U/L on day 14 that subsequently normalized promptly; none met Hy''s criteria for serious liver injury.

Conclusions

The mycobactericidal activity of sutezolid 600 mg BID or 1200 mg QD was readily detected in sputum and blood. Both schedules were generally safe and well tolerated. Further studies of sutezolid in tuberculosis treatment are warranted.

Trial Registration

ClinicalTrials.gov NCT01225640  相似文献   

15.
T Cheung  S Oberoi 《PloS one》2012,7(8):e43405

Introduction

Children with cleft lip and palate (CLP) are known to have airway problems. Previous studies have shown that individuals with CLP have a 30% reduction in nasal airway size compared to non-cleft controls. No reports have been found on cross-sectional area and volume of the pharyngeal airway in clefts. Introduction of Cone-Beam CT (CBCT) and imaging software has facilitated generation of 3D images for assessment of the cross-sectional area and volume of the airway.

Objective

To assess the pharyngeal airway in individuals with CLP using CBCT by measuring volume and smallest cross-sectional areas and compare with 19 age- and sex-matched non-cleft controls.

Methods

Retrospective study of CBCT data of pre-adolescent individuals (N = 19, Mean age = 10.6, 7 females, 12 males, UCLP = 6, BCLP = 3) from the Center for Craniofacial Anomalies. Volumetric analysis was performed using image segmentation features in CB Works 3.0. Volume and smallest cross-sectional were studied in both groups. Seven measurements were repeated to verify reliability using Pearson correlation coefficient. Volume and cross-sectional area differences were analyzed using paired t-tests.

Results

The method was found to be reliable. Individuals with CLP did not exhibit smaller total airway volume and cross sectional area than non-CLP controls.

Conclusion

3D imaging using CBCT and CB Works is reliable for assessing airway volume. Previous studies have shown that the nasal airway is restricted in individuals with CLP. In our study, we found that the pharyngeal airway is not compromised in these individuals.  相似文献   

16.

Background

There is a paucity of information on structural organization of muscular bundles in the interatrial septum (IAS). The aim was to investigate histologic and ultrastructural organization of muscular bundles in human IAS, including fossa ovalis (FO) and flap valve.

Methods

Macroscopic and light microscopy evaluations of IAS were performed from postmortem studies of 40 patients. Twenty three IAS specimens underwent serial transverse sectioning, and 17 - longitudinal sectioning. The transverse sections from 10 patients were immunolabeled for HCN4, Caveolin3 and Connexin43. IAS specimens from 6 other patients underwent electron microscopy.

Results

In all IAS specimens sections the FO, its rims and the flap valve had muscle fibers consisting of working cardiac myocytes. Besides the typical cardiomyocytes there were unusual cells: tortuous and horseshoe-shaped intertangled myocytes, small and large rounded myocytes with pale cytoplasm. The cells were aggregated in a definite structure in 38 (95%) cases, which was surrounded by fibro-fatty tissue. The height of the structure on transverse sections positively correlated with age (P = 0.03) and AF history (P = 0.045). Immunohistochemistry showed positive staining of the cells for HCN4 and Caveolin3. Electron microscopy identified cells with characteristics similar to electrical conduction cells.

Conclusions

Specialized conduction cells in human IAS have been identified, specifically in the FO and its flap valve. The cells are aggregated in a structure, which is surrounded by fibrous and fatty tissue. Further investigations are warranted to explore electrophysiological characteristics of this structure.  相似文献   

17.

Background

Information leaflets are widely used to increase awareness and knowledge of disease. Limited research has, to date, been undertaken to evaluate the efficacy of these information resources. This pilot study sought to determine whether information leaflets developed specifically for staff working with substance mis-users improved knowledge of tuberculosis (TB).

Method

Staffs working with individuals affected by substance mis-use were recruited between January and May 2008. All participants were subjectively allocated by their line manager either to receive the TB-specific leaflet or a control leaflet providing information on mental health. Level of knowledge of TB was assessed using questionnaires before and after the intervention and data analysed using McNemar''s exact test for matched pairs.

Results

The control group showed no evidence of a change in knowledge of TB, whereas the TB questionnaire group demonstrated a significant increase in knowledge including TB being curable (81% correct before to 100% correct after), length of treatment required (42% before to 73% after), need to support direct observation (18% to 62%) and persistent fever being a symptom (56% to 87%). Among key workers, who have a central role in implementing a care plan, 88% reported never receiving any TB awareness-raising intervention prior to this study, despite 11% of all respondents having TB diagnosed among their clients.

Conclusion

Further randomized controlled trials are required to confirm the observed increase in short-term gain in knowledge and to investigate whether knowledge gain leads to change in health status.  相似文献   

18.
Venous valve incompetence has been implicated in diseases ranging from chronic venous insufficiency (CVI) to intracranial venous hypertension. However, while the mechanical properties of venous valve leaflet tissues are central to CVI biomechanics and mechanobiology, neither stress–strain curves nor tangent moduli have been reported. Here, equibiaxial tensile mechanical tests were conducted to assess the tangent modulus, strength and anisotropy of venous valve leaflet tissues from bovine jugular veins. Valvular tissues were stretched to 60% strain in both the circumferential and radial directions, and leaflet tissue stress–strain curves were generated for proximal and distal valves (i.e., valves closest and furthest from the right heart, respectively). Toward linking mechanical properties to leaflet microstructure and composition, Masson’s trichrome and Verhoeff–Van Gieson staining and collagen assays were conducted. Results showed: (1) Proximal bovine jugular vein venous valves tended to be bicuspid (i.e., have two leaflets), while distal valves tended to be tricuspid; (2) leaflet tissues from proximal valves exhibited approximately threefold higher peak tangent moduli in the circumferential direction than in the orthogonal radial direction (i.e., proximal valve leaflet tissues were anisotropic; \(p<0.01\)); (3) individual leaflets excised from the same valve apparatus appeared to exhibit different mechanical properties (i.e., intra-valve variability); and (4) leaflets from distal valves exhibited a trend of higher soluble collagen concentrations than proximal ones (i.e., inter-valve variability). To the best of the authors’ knowledge, this is the first study reporting biaxial mechanical properties of venous valve leaflet tissues. These results provide a baseline for studying venous valve incompetence at the tissue level and a quantitative basis for prosthetic venous valve design.  相似文献   

19.

Objectives

The aim of this study was to quantify potential differences in count, frequency and pattern of high-intensity transient signals (HITS) during transapical transcatheter aortic valve implantation (TA-TAVI), by comparing the Symetis Acurate TA (SA) with the balloon-expandable Edwards Sapien XT (ES) system.

Background

Recently, the Symetis Acurate TA revalving system has been introduced for TA-TAVI. The Symetis Acurate TA aortic bioprosthesis is self-expanding and is deployed by a specific two-step implantation technique. Whether this novel method increases the load of intraprocedural emboli, detected by transcranial Doppler ultrasound (TCD) as HITS, or not is not clear.

Methods

Twenty-two patients (n = 11 in each study arm, median logistic EuroScore 20%, median STS score 7%) displayed continuous TCD signals of good quality throughout the entire TA-TAVI procedure and were included in the final analysis. Data are presented as median with interquartile ranges.

Results

No significant differences were detected in total procedural or interval-related HITS load (SA: 303 [200; 594], ES: 499 [285; 941]; p = 0.16). With both devices, HITS peaked during prosthesis deployment (PD), whereas significantly fewer HITS occurred during instrumentation (SA: p = 0.002; ES: <0.001) or post-implantation PI (SA: p = 0.007; ES: <0.001). PD-associated HITS amounted to almost half of the total HITS load. One patient suffered new disabling stroke at 30 days. Thirty-day mortality amounted to 13.6% (3 of 22 patients).

Conclusions

Simplified transapical delivery using the self-expanding SA device does not increase HITS, despite of a two-step deployment technique with more interactions with the native aortic valve, when compared to the balloon-expandable ES valve. The similarity in HITS count, frequency and pattern with the two systems suggests a common mechanism for the release of cerebral microemboli.  相似文献   

20.

Background

Attention deficit hyperactivity disorder (ADHD) is a common comorbidity of childhood epilepsy, but the neuroanatomical correlates of ADHD in epilepsy have yet to be comprehensively characterized.

Methods

Children with new and recent-onset epilepsy with (n = 18) and without (n = 36) ADHD, and healthy controls (n = 46) underwent high resolution MRI. Measures of cortical morphology (thickness, area, volume, curvature) and subcortical and cerebellar volumes were compared between the groups using the program FreeSurfer 5.1.

Results

Compared to the control group, children with epilepsy and ADHD exhibited diffuse bilateral thinning in the frontal, parietal and temporal lobes, with volume reductions in the brainstem and subcortical structures (bilateral caudate, left thalamus, right hippocampus). There were very few group differences across measures of cortical volume, area or curvature.

Conclusions

Children with epilepsy and comorbid ADHD exhibited a pattern of bilateral and widespread decreased cortical thickness as well as decreased volume of subcortical structures and brainstem. These anatomic abnormalities were evident early in the course of epilepsy suggesting the presence of antecedent neurodevelopmental changes, the course of which remains to be determined.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号