Inseon Ryoo Seung Hong Choi Ji-Hoon Kim Chul-Ho Sohn Soo Chin Kim Hwa Seon Shin Jeong A. Yeom Seung Chai Jung A. Leum Lee Tae Jin Yun Chul-Kee Park Sung-Hye Park 《PloS one》2013,8(8)
Purpose
To evaluate the usefulness of dynamic susceptibility contrast (DSC) enhanced perfusion MR imaging in predicting major genetic alterations in glioblastomas.Materials and Methods
Twenty-five patients (M:F = 13∶12, mean age: 52.1±15.2 years) with pathologically proven glioblastoma who underwent DSC MR imaging before surgery were included. On DSC MR imaging, the normalized relative tumor blood volume (nTBV) of the enhancing solid portion of each tumor was calculated by using dedicated software (Nordic TumorEX, NordicNeuroLab, Bergen, Norway) that enabled semi-automatic segmentation for each tumor. Five major glioblastoma genetic alterations (epidermal growth factor receptor (EGFR), phosphatase and tensin homologue (PTEN), Ki-67, O6-methylguanine-DNA methyltransferase (MGMT) and p53) were confirmed by immunohistochemistry and analyzed for correlation with the nTBV of each tumor. Statistical analysis was performed using the unpaired Student t test, ROC (receiver operating characteristic) curve analysis and Pearson correlation analysis.Results
The nTBVs of the MGMT methylation-negative group (mean 9.5±7.5) were significantly higher than those of the MGMT methylation-positive group (mean 5.4±1.8) (p = .046). In the analysis of EGFR expression-positive group, the nTBVs of the subgroup with loss of PTEN gene expression (mean: 10.3±8.1) were also significantly higher than those of the subgroup without loss of PTEN gene expression (mean: 5.6±2.3) (p = .046). Ki-67 labeling index indicated significant positive correlation with the nTBV of the tumor (p = .01).Conclusion
We found that glioblastomas with aggressive genetic alterations tended to have a high nTBV in the present study. Thus, we believe that DSC-enhanced perfusion MR imaging could be helpful in predicting genetic alterations that are crucial in predicting the prognosis of and selecting tailored treatment for glioblastoma patients. 相似文献2.
See Min Choi Don Kyoung Choi Tae Heon Kim Byong Chang Jeong Seong Il Seo Seong Soo Jeon Hyun Moo Lee Han-Yong Choi Hwang Gyun Jeon 《PloS one》2015,10(3)
Objective
To investigate the difference between preoperative radiologic tumor volume (RTV) and postoperative pathologic tumor volume (PTV) in patients who received nephrectomy for renal cell carcinoma (RCC).Materials and Methods
We reviewed 482 patients who underwent preoperative computed tomography (CT) within 4 weeks before radical or partial nephrectomy for renal cell carcinoma. RTV measured by a three dimensional rendering program was compared with PTV (π/6ⅹheightⅹlengthⅹwidth) measured in surgical specimen according to pathologic tumor size and histologic subtype. Correlation of the inter-quartile range (IQR) of the RTV and Fuhrman nuclear grade was also investigated.Results
There was a significant positive linear correlation between RTV and PTV (p<0.001, r = 0.911), and the mean RTV and mean PTV were not significantly different (79.0 vs 76.9cm3, p = 0.393). For pathologic tumor size (PTS) <4cm, the mean RTV was larger than the mean PTV (10.9 vs 7.1cm3, p<0.001). For a PTS of 4-7cm, the mean RTV was larger than the mean PTV (56.0 vs 44.7cm3, p<0.001). However, for a PTS ≥7cm, there was no statistical difference between RTV and PTV (p>0.05). Among patients with clear cell RCC, the mean RTV was significantly larger than the mean PTV (p = 0.042), not for non-clear cell group (p = 0.055). As the quartile of the RTV increased, the Fuhrman grade also increased (p<0.001).Conclusions
RTV was correlated with PTV and pathologic grade. RTV was larger than the PTV for a tumor size 7 cm or less or in clear cell RCC. RTV may be useful to measure tumor burden preoperatively. 相似文献3.
目的:通过与常规冠脉造影(Digital Signature Algorithm,DSA)对比评估双低扫描(低放射剂量,低造影剂量)方案在320排动态容积CT冠脉成像(coronary angiography with CT,CCTA)中应用的可行性。方法:选取2014年5月2015年8月完成CCTA双低扫描30例患者为双低组,双低组根据患者体重指数采取相应的管电压(BMI重指数采取相应的管电压(BMI≤25 kg/m~2:80 kv,25 kg/m~2BMI≤28 kg/m~2:100 kv,BMI〉28 kg/m~2:120 kv),造影剂浓度选用320 mg I/m L,接受0.6 m L/kg的对比剂;完成双低扫描的30例患者并在CCTA检查的前后两周内同时完成了DSA检查为对照组,另外完成CCTA常规扫描检查的30例患者为常规组,电压设置为常规使用的120 kv管电压,造影剂浓度选用370 mg I/m L,以及均接受造影剂的量为65 m L。结果:与DSA比较,CCTA对诊断冠脉狭窄的敏感性、特异性、阳性预测值、阴性预测值分别为91%、94%、92%、93%,在诊断冠脉狭窄方面没有明显统计差异;与常规扫描比较,CCTA有效辐射剂量降低了约62%。结论:应用双低扫描的CCTA检查具有与DSA几乎同样的图像诊断质量,有效辐射剂量有了大幅度减低。 相似文献
4.
Qian Xie Juan Wu Ying Tang Yafang Dou Sijie Hao Feijia Xu Xiaoyuan Feng Zonghui Liang 《PloS one》2013,8(11)
Background
This study was performed to assess whether iterative reconstruction can reduce radiation dose while maintaining acceptable image quality, and to investigate whether perfusion parameters vary from conventional filtered back projection (FBP) at the low-tube-voltage (80-kVp) during whole-pancreas perfusion examination using a 256-slice CT.Methods
76 patients with known or suspected pancreatic mass underwent whole-pancreas perfusion by a 256-slice CT. High- and low-tube-voltage CT images were acquired. 120-kVp image data (protocol A) and 80-kVp image data (protocol B) were reconstructed with conventional FBP, and 80-kVp image data were reconstructed with iDose4 (protocol C) iterative reconstruction. The image noise; contrast-to-noise ratio (CNR) relative to muscle for the pancreas, liver, and aorta; and radiation dose of each protocol were assessed quantitatively. Overall image quality was assessed qualitatively. Among 76 patients, 23 were eventually proven to have a normal pancreas. Perfusion parameters of normal pancreas in each protocol including blood volume, blood flow, and permeability-surface area product were measured.Results
In the quantitative study, protocol C reduced image noise by 36.8% compared to protocol B (P<0.001). Protocol C yielded significantly higher CNR relative to muscle for the aorta, pancreas and liver compared to protocol B (P<0.001), and offered no significant difference compared to protocol A. In the qualitative study, protocols C and A gained similar scores and protocol B gained the lowest score for overall image quality (P<0.001). Mean effective doses were 23.37 mSv for protocol A and 10.81 mSv for protocols B and C. There were no significant differences in the normal pancreas perfusion values among three different protocols.Conclusion
Low-tube-voltage and iDose4 iterative reconstruction can dramatically decrease the radiation dose with acceptable image quality during whole-pancreas CT perfusion and have no significant impact on the perfusion parameters of normal pancreas compared to the conventional FBP reconstruction using a 256-slice CT scanner. 相似文献5.
T. P. Stephenson E. P. N. O'Donoghue W. F. Hendry J. E. A. Wickham 《BMJ (Clinical research ed.)》1973,1(5850):379-381
Twenty-six human cadaveric kidneys have been preserved for up to 36 hours by continuous perfusion with 4·5% albumin solution on a Gambro machine. Of these, 20 kidneys were transplanted, and six were discarded owing to poor perfusion characteristics during storage. Immediate function was obtained with four kidneys, of which two had been preserved for over 30 hours.Satisfactory renal function has been obtained with 17 kidneys, and three kidneys were lost owing to rejection or technical complications. It is our experience that human kidneys can be successfully preserved for up to 36 hours by this technique. 相似文献
6.
目的比较不同计算和测量方法评价移植瘤体积的异同,以探索最佳的接近真实体积的计算和测量方法。方法利用裸鼠皮下移植人原发性肝癌细胞株SMMC-7721建立人肝癌移植瘤动物模型。将荷瘤裸鼠随机分为三组,分别注射PBS液、Ad-LacZ、Ad-p27mt。处理后2周、3周分别处死裸鼠,在体体外内测量移植瘤的长径(a),宽径(b)及高(c),通过4种不同的体积测量公式(πabb/6、abb/2、aab/2、πabc/6)计算出移植瘤体积。同时测出移植瘤近似真实体积。结果πabc/6法计算体积与近似真实体积无明显差异性(P〉0.05),πabb/6、abb/2、aab/2法与近似真实体积有明显差异性(P〈0.05)。πabc/6法计算体积(cm3)、近似真实体积(cm3)与其重量(g)无明显差异性(P〉0.05),而πabb/6、abb/2、aab/2法计算体积(cm3)与重量有明显差异性(P〈0.05)。在体体内外方法测得的数据通过四种方法计算出来的体积均无明显差异(P〉0.05)。结论4种不同的体积测量公式(πabb/6、abb/2、aab/2、πabc/6),以V=πabc/6方法计测移植瘤体积最准确、客观。在体移植瘤亦可通过游标卡尺测量肿瘤高度,通过v=πabc/6法准确计算出移植瘤体积及推算出移植瘤重量。 相似文献
7.
To investigate the clinical significance of 128 slice whole liver four dimensional computed tomography (4D CT) in diagnosis and differential diagnosis of hepatic disease, by characterizing and comparing perfusion maps in two common hepatic tumors: hepatocellular carcinoma (HCC) and liver hemangioma. 45 patients with HCC and 40 patients with liver hemangioma were subjected to 128 slice 4D CT of the whole liver perfusion scan, perfusion images were obtained, and data were processed by the perfusion software. Four perfusion parameters generated automatically were used to characterize and compare the perfusion of tumor tissue and surrounding hepatic parenchyma: blood flow perfusion (BF), arterial liver perfusion (ALP), portal venous perfusion (PVP), and hepatic perfusion index (HPI). Volumetric CT perfusion data then reconstructed to yield 4D CT angiography. Morphological observation was made regarding to the blood supply of tumor, intrahepatic vasculature. (1) In both HCC and hepatic hemangioma, BF, ALP, HPI were higher (P < 0.01), whereas PVP were lower (P < 0.01) in tumor tissue than the surrounding hepatic parenchyma (within 1 cm of lesion). Compared with liver hemangioma tumor tissue, BF, ALP, PVP were lower in HCC tumor tissue (P < 0.05; 0.01; 0.01), but HPI is higher (P < 0.05). For the perfusion of the surrounding parenchyma, BF and ALP were higher (P < 0.001), PVP was lower (P < 0.001) in HCC, while HPI was unchanged. (2) Among 45 cases with HCC, cancer feeding artery was found in 28 cases. In 20 cases feeding artery was shown as thickening, rigid, or distorted. Tumor thrombus in portal vein was found in 14 cases. For total of 40 cases with liver hemangioma, in 23 cases blood vessels are shifted due to compression from tumor mass, the rest 17 cases show normal vasculature. With application of 128 slice 4D CT, whole liver perfusion scan can reliably reflect the hemodynamic characteristics of HCC and hepatic hemangioma, proving to be a valuable adjunct to conventional imaging techniques of liver for early detection, differential diagnosis, and determining surgical resection range as well as estimating prognosis for hepatic tumors. 相似文献
8.
In 19 young human multiorgan donors, we simultaneously analyzed the bacterial contamination of the kidney perfusion fluid and all retrieved bone allografts. Donor exclusion criteria were done according to the American and European Association of Tissue Banks excluding all patients with perforating wounds. The kidney perfusate revealed a contamination in 17 of 19 (89.5%) donors. Allograft testing demonstrated positive bacterial growth in 34 of 76 allografts (44.7%). Microorganisms originated from the normal skin flora and could be related to contamination during the harvesting procedure. In 5 cases we cultured identical bacterial subspecies in both cultures as a possible sign for systemic bacterial spreading during the multiorgan harvesting procedure. 相似文献
9.
Alan J. Riordan Edwin Bennink Jan Willem Dankbaar Max A. Viergever Birgitta K. Velthuis Ewoud J. Smit Hugo W. A. M. de Jong 《PloS one》2014,9(5)
Purpose
In brain CT perfusion (CTP), the arterial contrast bolus is scaled to have the same area under the curve (AUC) as the venous outflow to correct for partial volume effects (PVE). This scaling is based on the assumption that large veins are unaffected by PVE. Measurement of the internal carotid artery (ICA), usually unaffected by PVE due to its large diameter, may avoid the need for partial volume correction. The aims of this work are to examine i) the assumptions behind PVE correction and ii) the potential of selecting the ICA obviating correction for PVE.Methods
The AUC of the ICA and sagittal sinus were measured in CTP datasets from 52 patients. The AUCs were determined by i) using commercial CTP software based on a Gaussian curve-fitting to the time attenuation curve, and ii) by simple integration of the time attenuation curve over a time interval. In addition, frames acquired up to 3 minutes after first bolus passage were used to examine the ratio of arterial and venous enhancement. The impact of selecting the ICA without PVE correction was illustrated by reporting cerebral blood volume (CBV) measurements.Results
In 49 of 52 patients, the AUC of the ICA was significantly larger than that of the sagittal sinus (p = 0.017). Measured after the first pass bolus, contrast enhancement remained 50% higher in the ICA just after the first pass bolus, and 30% higher 3 minutes later. CBV measurements were significantly lowered when the ICA was used without PVE correction.Conclusions
Contradicting the assumptions underlying PVE correction, contrast in the ICA was significantly higher than in the sagittal sinus, even 3 minutes after the first pass of the contrast bolus. PVE correction might lead to overestimation of CBV if the CBV is calculated using the AUC of the time attenuation curves. 相似文献10.
Daniela Muenzel Sven Kabus Bettina Gramer Vivian Leber Mani Vembar Holger Schmitt Moritz Wildgruber Alexander A. Fingerle Ernst J. Rummeny Armin Huber Peter B. No?l 《PloS one》2013,8(10)
Objective
To improve image and diagnostic quality in dynamic CT myocardial perfusion imaging (MPI) by using motion compensation and a spatio-temporal filter.Methods
Dynamic CT MPI was performed using a 256-slice multidetector computed tomography scanner (MDCT). Data from two different patients–with and without myocardial perfusion defects–were evaluated to illustrate potential improvements for MPI (institutional review board approved). Three datasets for each patient were generated: (i) original data (ii) motion compensated data and (iii) motion compensated data with spatio-temporal filtering performed. In addition to the visual assessment of the tomographic slices, noise and contrast-to-noise-ratio (CNR) were measured for all data. Perfusion analysis was performed using time-density curves with regions-of-interest (ROI) placed in normal and hypoperfused myocardium. Precision in definition of normal and hypoperfused areas was determined in corresponding coloured perfusion maps.Results
The use of motion compensation followed by spatio-temporal filtering resulted in better alignment of the cardiac volumes over time leading to a more consistent perfusion quantification and improved detection of the extend of perfusion defects. Additionally image noise was reduced by 78.5%, with CNR improvements by a factor of 4.7. The average effective radiation dose estimate was 7.1±1.1 mSv.Conclusion
The use of motion compensation and spatio-temporal smoothing will result in improved quantification of dynamic CT MPI using a latest generation CT scanner. 相似文献11.
The objective of this study is to assess the clinical role of computed tomography angiography (CTA) in determining the etiology of aneurysmal subarachnoid hemorrhage (ASAH) and selecting the treatment options. A total of 452 patients with ASAH underwent a 64-slice CTA examination to determine the etiology and select the treatment strategies. Digital subtraction angiography (DSA) or clipping operation confirmed the detection from the CTA. The CTA results of 452 patients with ASAH were confirmed through the DSA or clipping operation and the CTA results of 451 cases were consistent with what were seen during the DSA or clipping operation. The treatment choices for 451 patients (99.8 %) were based on the CTA results. A total of 90 cases (19.9 %) underwent endovascular embolization and 362 cases (80.1 %) underwent clipping operation. The other one patient underwent endovascular embolization after the DSA examination due to insufficient information from the CTA. Also, there was one patient who was misdiagnosed in the CTA. In conclusion, a 64-slice CTA can accurately detect intracranial aneurysms and is helpful in choosing the best treatment option. 相似文献
12.
目的:采用多层螺旋CT灌注成像探讨正常大鼠脑血流动力学特征.方法:对15只健康Wistar大鼠进行CT灌注扫描,定量测定全脑不同区域的血流动力学参数,分析正常Wistar大鼠脑血流动力学特征.结果:正常Wistar大鼠脑部不同区域的血流动力学参数存在较大差异(P<0.05或0.01),Wistar大鼠的CBF和CBV值以小脑最高,其次是基底节区和延髓,大脑皮质的CBF和CBV值较低:而MTT值在Wistar大鼠脑部各区域比较接近,均值比较无统计学意义(P>0.05).结论:多层螺旋CT可用于定量评价Wistar大鼠脑组织的血液动力学特征,完全适用于小型动物模型脑部血流动力学的研究. 相似文献
13.
Yu Chen Huadan Xue Zheng-yu Jin Jie Zhang Hao Sun Xuan Wang Zhu-hua Zhang Da-ming Zhang Guang-ming Lu Zhao-qi Zhang U. Joseph Schoepf Andreas M. Bucher Christopher D. Wolla Yun Wang 《PloS one》2013,8(11)
Background
Our study aims to evaluate the image quality and feasibility of 128-slice dual-energy CTA (DE-CTA) for supra-aortic arteries using reduced amounts of contrast medium (CM).Methods
A prospective study was performed in 54 patients receiving CTA of the head and neck with a 128-slice dual-source CT system. Patients were randomized into two groups with a volume of either 40 mL of CM (Group I) or 50 mL of CM (Group II). Arterial and venous enhancements were recorded for quantitative assessment. Qualitative assessments for images without bone removal (BR) were based on a) the visualization of the circle of Willis and b) streak artifacts due to residual CM in the subclavian or internal jugular veins ipsilateral to injection of CM. Qualitative assessment of dual-energy images using BR was based on the presence of bone remnants and vessel integrity. Quantitative data was compared using the Student t test. The χ2 test was used for the qualitative measurements of streak artifacts in veins while the Mann-Whitney U test was used for the qualitative measurements of images with BR.Results
Arterial and venous attenuation was significantly higher in Group II (P=0.000). Image quality regarding the circle of Willis was excellent in both groups (3.90±0.30 for Group I and 4.00±0 for Group II) . Imaging of the internal jugular veins was scored higher in Group I (1.87±0.72) compared with Group II (1.48±0.51) (P=0.021). Within Group I using BR, mean scores for bone remnants did not differ significantly (P>0.05) but mean scores of vessel integrity (P<0.05) did.Conclusions
Contrast-enhanced head and neck CTA is feasible using a scan protocol with low amounts of contrast medium (40 mL) on a 128-slice dual-energy CTA. The 40-mL protocol provides satisfactory image quality before and after dual-energy bone-removal post-processing. 相似文献14.
Aim
To determine the optimal dose reduction level of iterative reconstruction technique for paediatric chest CT in pig models.Materials and Methods
27 infant pigs underwent 640-slice volume chest CT with 80kVp and different mAs. Automatic exposure control technique was used, and the index of noise was set to SD10 (Group A, routine dose), SD12.5, SD15, SD17.5, SD20 (Groups from B to E) to reduce dose respectively. Group A was reconstructed with filtered back projection (FBP), and Groups from B to E were reconstructed using iterative reconstruction (IR). Objective and subjective image quality (IQ) among groups were compared to determine an optimal radiation reduction level.Results
The noise and signal-to-noise ratio (SNR) in Group D had no significant statistical difference from that in Group A (P = 1.0). The scores of subjective IQ in Group A were not significantly different from those in Group D (P>0.05). There were no obvious statistical differences in the objective and subjective index values among the subgroups (small, medium and large subgroups) of Group D. The effective dose (ED) of Group D was 58.9% lower than that of Group A (0.20±0.05mSv vs 0.48±0.10mSv, p <0.001).Conclusions
In infant pig chest CT, using iterative reconstruction can provide diagnostic image quality; furthermore, it can reduce the dosage by 58.9%. 相似文献15.
16.
Study Design
A retrospective study of intradural extramedullary tumor.Objective
To compare the treatment results in the different surgeries of spinal intradural extramedullary tumor.Methods
The study retrospectively reviewed 122 patients. The minimally invasive surgery (MIS) group was divided into Group A (hemilaminectomy + tumor microscopic excision) and Group B (laminectomy + tumor microscopic excision + pedicle screw fixation). Meanwhile, the non-MIS group was divided into Group C (hemilaminectomy + tumor excision), Group D (laminectomy + tumor excision), and Group E (laminectomy + tumor excision + pedicle screw fixation). In order to study postoperative spinal stability, we simultaneously divided all of the subjects into three categories, namely Group HE: hemilaminectomy + tumor excision; Group LE: laminectomy + tumor excision; and Group LEPSF: laminectomy + tumor excision + pedicle screw fixation.Results
The MIS group exhibited fewer postoperative complications (p<0.05), better short-term clinical efficacy (p<0.05) and less non-surgical cost (p<0.05) than in non-MIS group. The rate of postoperative spinal instability in hemilaminectomy was lower than in laminectomy in a single spinal segment (p<0.05). The rate of postoperative spinal instability in laminectomy + pedicle screw fixation was lower than in hemilaminectomy and laminectomy in two or more spinal segments (p<0.05).Conclusion
In the case of appropriate surgical indications, minimally invasive surgery for intradural extramedullary tumor is a useful method that can successfully produce good clinical results and reduce non-surgical cost. In addition, pedicle screw fixation helps avoid spinal postoperative instability. 相似文献17.
Paweł Zagrodzki Fergus Nicol John R. Arthur Marian Słowiaczek Stanisław Walas Halina Mrowiec Renata Wietecha-Posłuszny 《Biological trace element research》2010,134(1):25-40
This study was performed to investigate selenoenzyme activities and trace element concentrations in thyroid tissues, with reference to other parameters routinely used to characterize thyroid function. This was to reveal relevant parameters as possible additional markers of tumor grade, clinical course, and prognosis of thyroid disorders. The tissue samples were obtained during surgical treatment (total or near total thyroidectomy) of 122 patients with different types of thyroid tumor. For most of the investigated parameters in different groups of patients, we did not find statistically significant differences. In the majority of cases, thyroid benign or malignant tumors were not accompanied by significant derangement of the gland selenoenzymes and of either intrathyroidal or plasma concentration of selenium. Nevertheless, types I and II iodothyronine deiodinases were the most promising (among selenoenzymes) targets for diagnoses and possibly therapy of thyroid tumors. Higher activities of both enzymes in cases with Graves’ disease, as compared with other thyroid lesions, suggest their involvement in the pathogenesis of this condition. Patients with struna nodosa had higher levels of thyroid Zn, Cu, and Pb as compared with papillary carcinoma subjects and also a higher level of Cu than follicular carcinoma cases. The above diagnostics may play a similar role to some of the general thyroid function indices, TSH, anti-TG, anti-TPO, and calcitonin, which can partially distinguish between various thyroid tumors. In conclusion, some of selenium status markers, when accompanied with general parameters, and trace elements can serve as factors with pathophysiologic relevance and be helpful in the identification of malignant disease. Multivariate statistical methods should be employed to tackle a broad array of thyroid tumor diagnostic data in a short time. Partial least squares model and other pattern recognition methods seem to be the most appropriate methods for that task. The miniaturization of all the steps of complex analytical procedure should be developed in a way to allow its completion as sensitive, robust, and efficient for use of the small quantity of material provided by fine-needle biopsy. 相似文献
18.
Seung Chai Jung Seung Hong Choi Jeong A. Yeom Ji-Hoon Kim Inseon Ryoo Soo Chin Kim Hwaseon Shin A. Leum Lee Tae Jin Yun Chul-Kee Park Chul-Ho Sohn Sung-Hye Park 《PloS one》2013,8(8)
Purpose
To compare the reproducibilities of manual and semiautomatic segmentation method for the measurement of normalized cerebral blood volume (nCBV) using dynamic susceptibility contrast-enhanced (DSC) perfusion MR imaging in glioblastomas.Materials and Methods
Twenty-two patients (11 male, 11 female; 27 tumors) with histologically confirmed glioblastoma (WHO grade IV) were examined with conventional MR imaging and DSC imaging at 3T before surgery or biopsy. Then nCBV (means and standard deviations) in each mass was measured using two DSC MR perfusion analysis methods including manual and semiautomatic segmentation method, in which contrast-enhanced (CE)-T1WI and T2WI were used as structural imaging. Intraobserver and interobserver reproducibility were assessed according to each perfusion analysis method or each structural imaging. Interclass correlation coefficient (ICC), Bland-Altman plot, and coefficient of variation (CV) were used to evaluate reproducibility.Results
Intraobserver reproducibilities on CE-T1WI and T2WI were ICC of 0.74–0.89 and CV of 20.39–36.83% in manual segmentation method, and ICC of 0.95–0.99 and CV of 8.53–16.19% in semiautomatic segmentation method, repectively. Interobserver reproducibilites on CE-T1WI and T2WI were ICC of 0.86–0.94 and CV of 19.67–35.15% in manual segmentation method, and ICC of 0.74–1.0 and CV of 5.48–49.38% in semiautomatic segmentation method, respectively. Bland-Altman plots showed a good correlation with ICC or CV in each method. The semiautomatic segmentation method showed higher intraobserver and interobserver reproducibilities at CE-T1WI-based study than other methods.Conclusion
The best reproducibility was found using the semiautomatic segmentation method based on CE-T1WI for structural imaging in the measurement of the nCBV of glioblastomas. 相似文献19.
目的:探讨采用SPECT/CT获得小型家猪脑血流灌注特征的方法和可行性.方法:对8头健康小型家猪进行SPECT/CT脑显像,进行图像预处理,自动提取脑相同感兴趣的相对血流量和相对离散度.结果:正常小猪脑不同感兴趣区相对血流量存在较大差异(P<0.05),相对脑血流量值以颞顶叶最高,其次是额顶叶,小脑最低.正常小猪脑各感兴趣内的相对离散度有统计学差异(P<0.05),相对离散度小脑感兴趣区最高,额叶感兴趣区最低.结论:SPECT/CT可用于半定量评价小型家猪脑血流灌注. 相似文献
20.
Binsheng Zhao Yongqiang Tan Wei Yann Tsai Lawrence H. Schwartz Lin Lu 《Translational oncology》2014,7(1):88-93
PURPOSE: To explore the effects of computed tomography (CT) slice
thickness and reconstruction algorithm on quantification of image features to characterize
tumors using a chest phantom. MATERIALS AND METHODS: Twenty-two phantom
lesions of known sizes (10 and 20 mm), shapes (spherical, elliptical, lobulated, and
spiculated), and densities [-630, -10, and +100 Hounsfield Unit (HU)] were inserted into
an anthropomorphic thorax phantom and scanned three times with relocations. The raw data
were reconstructed using six imaging settings, i.e., a combination of three slice
thicknesses of 1.25, 2.5, and 5 mm and two reconstruction kernels of lung and standard.
Lesions were segmented and 14 image features representing lesion size, shape, and texture
were calculated. Differences in the measured image features due to slice thickness and
reconstruction algorithm were compared using linear regression method by adjusting three
confounding variables (size, density, and shape). RESULTS: All 14
features were significantly different between 1.25 and 5 mm slice images. The 1.25 and 2.5
mm slice thicknesses were better than 5 mm for volume, density mean, density SD gray-level
co-occurrence matrix (GLCM) energy and homogeneity. As for the reconstruction algorithm,
there was no significant difference in uni-dimension, volume, shape index 9, and
compactness. Lung reconstruction was better for density mean, whereas standard
reconstruction was better for density SD. CONCLUSIONS: CT slice thickness
and reconstruction algorithm can significantly affect the quantification of image
features. Thinner (1.25 and 2.5 mm) and thicker (5 mm) slice images should not be used
interchangeably. Sharper and smoother reconstructions significantly affect the
density-based features. 相似文献