首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
For skill advancement, motor variability must be optimized based on target information during practice sessions. This study investigated structural changes in kinematic variability by characterizing submovement dynamics and muscular oscillations after practice with visuomotor tracking under different target conditions. Thirty-six participants were randomly assigned to one of three groups (simple, complex, and random). Each group practiced tracking visual targets with trajectories of varying complexity. The velocity trajectory of tracking was decomposed into 1) a primary contraction spectrally identical to the target rate and 2) an intermittent submovement profile. The learning benefits and submovement dynamics were conditional upon experimental manipulation of the target information. Only the simple and complex groups improved their skills with practice. The size of the submovements was most greatly reduced by practice with the least target information (simple > complex > random). Submovement complexity changed in parallel with learning benefits, with the most remarkable increase in practice under a moderate amount of target information (complex > simple > random). In the simple and complex protocols, skill improvements were associated with a significant decline in alpha (8–12 Hz) muscular oscillation but a potentiation of gamma (35–50 Hz) muscular oscillation. However, the random group showed no significant change in tracking skill or submovement dynamics, except that alpha muscular oscillation was reduced. In conclusion, submovement and gamma muscular oscillation are biological markers of learning benefits. Effective learning with an appropriate amount of target information reduces the size of submovements. In accordance with the challenge point hypothesis, changes in submovement complexity in response to target information had an inverted-U function, pertaining to an abundant trajectory-tuning strategy with target exactness.  相似文献   

2.
Central and peripheral factors were studied in fatigue of submaximal intermittent isometric contractions of the human quadriceps and soleus muscles. Subjects made repeated 6 s, 50% maximal voluntary contractions (MVC) followed by 4 s rest until the limit of endurance (Tlim). Periodically, a fatigue test was performed. This included a brief MVC, either a single shock or 8 pulses at 50 Hz during a rest period and a shock superimposed on a target force voluntary contraction. At Tlim, the MVC force had declined by 50%, usually in parallel with the force from stimulation at 50 Hz. The twitches superimposed on the target forces declined more rapidly, disappearing entirely at Tlim. In similar experiments on adductor pollicis, no reduction of the evoked M wave was seen. The results suggest that, during fatigue of quadriceps and adductor pollicis induced by this protocol, no central fatigue was apparent, but some was seen in soleus. Thus the reduced force-generating capacity could result mainly or entirely from failure of the muscle contractile apparatus.  相似文献   

3.
There is currently a controversy over whether stimulation frequencies should increase or decrease to optimize force output over time. This study compared changes in thenar muscle force and M-wave amplitude during progressively increasing (20–40 Hz), decreasing (40–20 Hz) and constant (20 Hz) frequency stimulation of the median nerve continuously for 3 min. Twenty-three individuals participated in three sets of experiments. There was no significant difference in the force–time integrals between the three fatigue tasks. The rate of fatigue was not correlated to the number of stimulation pulses delivered (20 Hz: 3600, 20–40 and 40–20 Hz: 5400). All fatigue tasks caused a significant reduction in M-wave amplitude and the reduction was largest for the 20–40 Hz protocol. However, multiple linear regression analysis revealed that the M-wave amplitude could not predict the changes in force over time for the 20 Hz or 20–40 Hz protocols. Thus during sustained evoked contractions with stimulation frequencies within the physiological range, frequencies can vary significantly without changing the overall force–time integral.  相似文献   

4.
This study compared motor unit rate coding and muscular force control in the first dorsal interosseous muscle of older (n = 11, mean 72.3 yr) and young (n = 12, mean 18.7 yr) adults. Rate coding during a sinusoidal isometric force-matching task was evaluated using spectral analysis of the time-varying changes in firing rate. The task required force modulations to match a trajectory comprising the sum of 0.15- and 0.45-Hz sine waves. Based on the amplitude of spectral peaks at 0.15 and 0.45 Hz, the amplitude of force modulation was similar in young and older adults at both frequencies (F = 1.9, P = 0.17). Force modulation gain (FMG) was computed as the ratio of the amplitude of force modulation to the amplitude of firing rate modulation. To account for rate coding differences related to the properties of the motoneuron, recruitment threshold force was used as a covariate in age-group comparisons. At both task frequencies, firing rate was modulated with less amplitude (F = 0 14, P < 0.001) and FMG was greater (F = 0 27, P < 0.001) in the older adults. In its transformation of neural input to mechanical output, muscle is known to act as a low-pass filter. Compared with modulation at 0.15 Hz, less change in force per change in firing rate at 0.45 Hz (lower FMG; F = 0 67, P < 0.001), independent of age group, is consistent with this filtering effect. Our conclusion is that there is a reduced amplitude of firing rate modulation in older adults.  相似文献   

5.
This study examined the mechanisms underlying amplitude modulation selectivity in the anuran auditory midbrain. Single units were recorded extracellularly in the torus semicircularis of the northern leopard frog, Rana pipiens. Two physiologically distinct classes of neurons were identified, based on their response latencies and their selectivities to pulse repetition rates. Cells in one group had short response latencies (median = 31 ms) and responded best to pulse repetition rates below 40 Hz. Tuning to low amplitude modulation rates was largely determined by recovery processes and phasic response properties. Cells in the second group had much longer latencies (median=81 ms) and were generally selective for pulse repetition rates greater than 40-50 Hz. Sensitivity to higher amplitude modulation rates resulted from integration processes; these units only responded when a threshold number of pulses were presented at a minimum pulse density (amplitude modulation rate). At amplitude modulation rates above their best rate, their responses decreased, apparently due to inadequate recovery time between pulses.  相似文献   

6.
Swarms of insects instrumented with wireless electronic backpacks have previously been proposed for potential use in search and rescue operations. Before deploying such biobot swarms, an effective long-term neural-electric stimulus interface must be established, and the locomotion response to various stimuli quantified. To this end, we studied a variety of pulse types (mono- vs. bipolar; voltage- vs. current-controlled) and shapes (amplitude, frequency, duration) to parameters that are most effective for evoking locomotion along a desired path in the Madagascar hissing cockroach (G. portentosa) in response to antennal and cercal stimulation. We identified bipolar, 2 V, 50 Hz, 0.5 s voltage controlled pulses as being optimal for evoking forward motion and turns in the expected contraversive direction without habituation in ≈50% of test subjects, a substantial increase over ≈10% success rates previously reported. Larger amplitudes for voltage (1–4 V) and current (50–150 μA) pulses generally evoked larger forward walking (15.6–25.6 cm; 3.9–5.6 cm/s) but smaller concomitant turning responses (149 to 80.0 deg; 62.8 to 41.2 deg/s). Thus, the radius of curvature of the initial turn-then-run locomotor response (≈10–25 cm) could be controlled in a graded manner by varying the stimulus amplitude. These findings could be used to help optimize stimulus protocols for swarms of cockroach biobots navigating unknown terrain.  相似文献   

7.
These data describe improved modulation of discharge rates (rate coding) of first dorsal interosseous motor units throughout the acquisition of a complex force-matching skill involving isometric index finger abduction. In each of 15 consecutive trials, subjects attempted to match their force to a trajectory consisting of the sum of two sine waves (0.15 and 0.5 Hz) and random oscillations (overall mean force level ˜20% MVC). Reductions in root-mean-square (RMS) error of each subject’s force relative to the trajectory indicated substantial improvements in force-matching ability (F=33.8, p<0.001). With the acquisition of this new skill, there was increased amplitude modulation of muscular force near both dominant frequencies of the force-matching trajectory (F=10.6, p=0.008). The standard deviation and coefficient of variation of motor unit inter-spike intervals both decreased with improved performance indicating a general reduction in the amplitude of firing rate modulations (SD: F=18.69, p=0.001; CV: F=43.6, p<0.001). After skill acquisition, there was decreased firing rate modulation outside of the two dominant frequencies and increased amplitude of firing rate modulation at the higher of the two dominant frequencies (0.5 Hz, F=8.23, p=0.015). These findings indicate that improved precision of rate coding was a contributor to the acquisition of the new force-matching task. That the change in rate coding was frequency dependent suggests that factors other than frequency coding may contribute to the improved force matching at 0.15 Hz.  相似文献   

8.
The aim of this study was to determine the effect of the time after spinal cord injury (less than and greater than 10 months) on the mechanical and electrophysiological characteristics of muscle fatigue of the paralyzed electrically stimulated quadriceps muscle. Morphologically and histochemically, a relationship was observed between muscle fatigue and the delay from injury, revealing a critical period of enzymatic turning and a maximum peak of atrophy around the 10th month after the injury, followed by a long-term stabilization. Knee-torque output and M-wave variables (amplitude, latency, duration, and root mean square, RMS) of two muscular heads of the quadriceps were recorded in 19 paraplegic patients during a 120-s isometric contraction. The fatiguing muscle contraction was elicited by supramaximal continuous 20-Hz electrical stimulation. Compared to the chronic group, the acutely paralyzed group showed a greater resistance to fatigue (amount and rate of force decline, P < or = 0.01), smaller alterations of the M-wave amplitude and RMS, and a limited decrease of the muscle fiber conduction velocity (P < 0.05). Mechanical and electrophysiological changes during fatigue provided a clear functional support of the transformation of skeletal muscle under the lesion and of the existence of a critical period of muscular turn. In conclusion, when considering the artificial restoration of motor function, the evolution of the endurance and force-generating capabilities of the muscle actuator must be taken into account, particularly when tasks require important safety conditions (e.g., standing and walking).  相似文献   

9.
Mechanical and electrical properties were studied for the first dorsal interosseous muscle of the dominant (d-FDI) and non-dominant hand (nd-FDI). Observations were made before, during and after a fatigue test, fatigue being evoked by percutaneous electrical stimulation of the ulnar nerve. The test consisted of 30 Hz bursts of ten supramaximal 0.1 ms pulses, repeated once a second for 5 min. The measurements included the amplitude of the first and fifth compound muscle action potentials (M-waves) within bursts, the peak burst force and the amplitude and time course of single twitches. At the end of the fatigue test, burst force had decreased to about the same extent in the FDI of both hands. The final decline in first M-wave amplitude was, however, significantly more pronounced for the nd-FDI than for the d-FDI. There were no longer any significant discrepancies between the two muscles after a subsequent recovery-period of 15 min. Comparisons among nd-FDI of various individuals demonstrated the presence of significant inter-individual differences in fatigue-related force-drop without any associated differences in M-wave decline. Intra-individual variability was similar for fatigue-related force-drop and M-wave decline.  相似文献   

10.
Summary In order to determine whether correlations exist between hearing and the known soundproduction abilities in piranhas (Serrasalmus nattereri), behavioral auditory thresholds were obtained with continuous tones and tone pulses. A new avoidance conditioning method was developed, where fin movements of caged animals were taken as response to a tone. The mean values of the far-field audiogram ranged from –26 dB re. 0.1 Pa at 80 Hz to a low point of about –43 dB between 220–350 Hz and rose to –14 dB at 1500 Hz. The frequency spectrum of typical drumming sounds (barks) covers the range of best hearing (100–600 Hz).Piranhas are able to integrate temporally acoustic signals: in threshold investigations with repeated tone pulses, the thresholds rose approximately exponentially with decreasing pulse duration and repetition rate; thresholds of single pulses were higher with shorter pulses. The temporal patterning of the calls and the temporal integration ability are well correlated in piranhas, optimizing intraspecific detectability and total length of sound production with respect to the fatigue characteristics of drumming muscles and habituation of the neural pacemaker.The lagenae of the piranhas were found to face laterofrontally; this is thought to be a morphological adaptation to sound production, saving the lagenae from excessive strain during activation of the drumming muscles.Abbreviations Cl acoustic condition 1, where a board with the air loudspeaker rested on the experimental tank upon a layer of felt - C2 acoustic condition 2, where the loudspeaker was freely mounted 20 cm above the water surface - d p pulse duration - f p pulse repetition rate - D duty cycle  相似文献   

11.
Oscillations in force output change in specific frequency bins and have important implications for understanding aging and pathological motor control. Although previous studies have demonstrated that oscillations from 0–1 Hz can be influenced by aging and visuomotor processing, these studies have averaged power within this bandwidth and not examined power in specific frequencies below 1 Hz. The purpose was to determine whether a differential modulation of force below 1 Hz contributes to changes in force control related to manipulation of visual feedback and aging. Ten young adults (25±4 yrs, 5 men) and ten older adults (71±5 yrs, 4 men) were instructed to accurately match a target force at 2% of their maximal isometric force for 35 s with abduction of the index finger. Visual feedback was manipulated by changing the visual angle (0.05°, 0.5°, 1.5°) or removing it after 15 s. Modulation of force below 1 Hz was quantified by examining the absolute and normalized power in seven frequency bins. Removal of visual feedback increased normalized power from 0–0.33 Hz and decreased normalized power from 0.66–1.0 Hz. In contrast, magnification of visual feedback (visual angles of 0.5° and 1.5°) decreased normalized power from 0–0.16 Hz and increased normalized power from 0.66–1.0 Hz. Older adults demonstrated a greater increase in the variability of force with magnification of visual feedback compared with young adults (P = 0.05). Furthermore, older adults exhibited differential force modulation of frequencies below 1 Hz compared with young adults (P<0.05). Specifically, older adults exhibited greater normalized power from 0–0.16 Hz and lesser normalized power from 0.66–0.83 Hz. The changes in force modulation predicted the changes in the variability of force with magnification of visual feedback (R2 = 0.80). Our findings indicate that force oscillations below 1 Hz are associated with force control and are modified by aging and visual feedback.  相似文献   

12.
We examined the mechanisms that underlie band-suppression amplitude modulation selectivity in the auditory midbrain of anurans. Band-suppression neurons respond well to low (5–10 Hz) and high (>70 Hz) rates of sinusoidal amplitude modulation, but poorly, if at all, to intermediate rates. The effectiveness of slow rates of sinusoidal amplitude modulation is due to the long duration of individual pulses; short-duration pulses (<10 ms) failed to elicit spikes when presented at 5–10 pulses s–1. Each unit responded only after a threshold number of pulses (median=3, range=2–5) were delivered at an optimal rate. The salient stimulus feature was the number of consecutive interpulse intervals that were within a cell-specific tolerance. This interval-integrating process could be reset by a single long interval, even if preceded by a suprathreshold number of intervals. These findings indicate that band-suppression units are a subset of interval-integrating neurons. Band-suppression neurons differed from band-pass interval-integrating cells in having lower interval-number thresholds and broader interval tolerance. We suggest that these properties increase the probability of a postsynaptic spike, given a particular temporal pattern of afferent action potentials in response to long-duration pulses, i.e., predispose them to respond to slow rates of amplitude modulation. Modeling evidence is provided that supports this conclusion.Abbreviations AM amplitude modulation - PRR pulse repetition rate - SAM sinusoidal amplitude modulation  相似文献   

13.
We hypothesized that muscle fiber bundles produce reactive oxygen intermediates and that reactive oxidant species contribute to muscular fatigue in vitro. Fiber bundles from rat diaphragm were mounted in chambers containing Krebs-Ringer solution. In studies of intracellular oxidant kinetics, bundles were loaded with 2',7'-dichlorofluorescin, a fluorochrome that emits at 520 nm when oxidized; emissions were quantified using a fluorescence microscope. Emissions from unstimulated muscles increased over time (P < 0.001). Accumulation of fluorescence was slowed by addition of catalase (P < 0.001) or superoxide dismutase (P < 0.001) and was accelerated by repetitive muscular contraction (P < 0.05). To determine effects of reactive oxygen intermediates on fatigue, curarized bundles were stimulated to contract isometrically; force was measured. Catalase, superoxide dismutase, and dimethyl sulfoxide were screened for effects on low- and high-frequency fatigue. Antioxidants inhibited low-frequency fatigue [after 5 min of repetitive contractions, force at 30 Hz was 20% greater than control (P < 0.015)] and increased the variability of fatigue at 30 Hz (P < 0.03). Antioxidants did not alter high-frequency (200-Hz) fatigue. We conclude that 1) diaphragm fiber bundles produce reactive oxygen intermediates, including O2-. and H2O2; 2) muscular contraction increases intracellular oxidant levels; and 3) reactive oxygen intermediates promote low-frequency fatigue in this preparation.  相似文献   

14.
Sleep deprivation (SD) adversely affects brain function and is accompanied by frequency dependent changes in EEG. Recent studies have suggested that BOLD fluctuations pertain to a spatiotemporal organization with different frequencies. The present study aimed to investigate the frequency-dependent SD-related brain oscillatory activity by using the amplitude of low-frequency fluctuation (ALFF) analysis. The ALFF changes were measured across different frequencies (Slow-4: 0.027–0.073 Hz; Slow-5: 0.01–0.027 Hz; and Typical band: 0.01–0.08 Hz) in 24 h SD as compared to rested wakeful during resting-state fMRI. Sixteen volunteers underwent two fMRI sessions, once during rested wakefulness and once after 24 h of SD. SD showed prominently decreased ALFF in the right inferior parietal lobule (IPL), bilateral orbitofrontal cortex (OFC) and dorsolateral prefrontal cortex (DLPFC), while increased ALFF in the visual cortex, left sensorimotor cortex and fusiform gyrus. Across the Slow-4 and Slow-5, results differed significantly in the OFC, DLPFC, thalamus and caudate in comparison to typical frequency band; and Slow-4 showed greater differences. In addition, negative correlations of behavior performance and ALFF patterns were found mainly in the right IPL across the typical frequency band. These observations provided novel insights about the physiological responses of SD, identified how it disturbs the brain rhythms, and linked SD with frequency-dependent alterations in amplitude patterns.  相似文献   

15.
Conventional (CONV) neuromuscular electrical stimulation (NMES) (i.e., short pulse duration, low frequencies) induces a higher energetic response as compared to voluntary contractions (VOL). In contrast, wide-pulse, high-frequency (WPHF) NMES might elicit–at least in some subjects (i.e., responders)–a different motor unit recruitment compared to CONV that resembles the physiological muscle activation pattern of VOL. We therefore hypothesized that for these responder subjects, the metabolic demand of WPHF would be lower than CONV and comparable to VOL. 18 healthy subjects performed isometric plantar flexions at 10% of their maximal voluntary contraction force for CONV (25 Hz, 0.05 ms), WPHF (100 Hz, 1 ms) and VOL protocols. For each protocol, force time integral (FTI) was quantified and subjects were classified as responders and non-responders to WPHF based on k-means clustering analysis. Furthermore, a fatigue index based on FTI loss at the end of each protocol compared with the beginning of the protocol was calculated. Phosphocreatine depletion (ΔPCr) was assessed using 31P magnetic resonance spectroscopy. Responders developed four times higher FTI’s during WPHF (99 ± 37 ×103 N.s) than non-responders (26 ± 12 ×103 N.s). For both responders and non-responders, CONV was metabolically more demanding than VOL when ΔPCr was expressed relative to the FTI. Only for the responder group, the ∆PCr/FTI ratio of WPHF (0.74 ± 0.19 M/N.s) was significantly lower compared to CONV (1.48 ± 0.46 M/N.s) but similar to VOL (0.65 ± 0.21 M/N.s). Moreover, the fatigue index was not different between WPHF (-16%) and CONV (-25%) for the responders. WPHF could therefore be considered as the less demanding NMES modality–at least in this subgroup of subjects–by possibly exhibiting a muscle activation pattern similar to VOL contractions.  相似文献   

16.
The ubiquitous brain oscillations occur in bursts of oscillatory activity. The present report tries to define the statistical characteristics of electroencephalographical (EEG) bursts of oscillatory activity during resting state in humans to define (i) the statistical properties of amplitude and duration of oscillatory bursts, (ii) its possible correlation, (iii) its frequency content, and (iv) the presence or not of a fixed threshold to trigger an oscillatory burst. The open eyes EEG recordings of five subjects with no artifacts were selected from a sample of 40 subjects. The recordings were filtered in frequency ranges of 2 Hz wide from 1 to 99 Hz. The analytic Hilbert transform was computed to obtain the amplitude envelopes of oscillatory bursts. The criteria of thresholding and a minimum of three cycles to define an oscillatory burst were imposed. Amplitude and duration parameters were extracted and they showed durations between hundreds of milliseconds and a few seconds, and peak amplitudes showed a unimodal distribution. Both parameters were positively correlated and the oscillatory burst durations were explained by a linear model with the terms peak amplitude and peak amplitude of amplitude envelope time derivative. The frequency content of the amplitude envelope was contained in the 0–2 Hz range. The results suggest the presence of amplitude modulated continuous oscillations in the human EEG during the resting conditions in a broad frequency range, with durations in the range of few seconds and modulated positively by amplitude and negatively by the time derivative of the amplitude envelope suggesting activation-inhibition dynamics. This macroscopic oscillatory network behavior is less pronounced in the low-frequency range (1–3 Hz).  相似文献   

17.
The purpose of this paper is to evaluate the muscular activation of the forearm, with or without vibration stimuli at different frequencies while performing a grip tasks of 45 s at various level of exerted force. In 16 individuals, 9 females and 7 males, the surface electromyogram (EMG) of extensor carpi radialis longus and the flexor carpi ulnari muscles were assessed. At a short latency from onset EMG, RMS and the level of MU synchronization were assessed to evaluate the muscular adaptations. Whilst a trend of decay of EMG Median frequency (MDFd) was employed as an index of muscular fatigue. Muscular tasks consists of the grip of an instrumented handle at a force level of 20%, 30%, 40%, 60% of the maximum voluntary force. Vibration was supplied by a shaker to the hand in mono-frequential waves at 20, 30, 33 and 40 Hz. In relation to EMG, RMS and MU synchronization, the muscular activation does not seem to change with the superimposition of the mechanical vibrations, on the contrary a lower MDFd was observed at 33 Hz than in absence of vibration. This suggests an early muscular fatigue induced by vibration due to the fact that 33 Hz is a resonance frequency for the hand-arm system.  相似文献   

18.
During standard electrochemotherapy (ECT), using a train of 1,000 V/cm amplitude rectangular pulses with 1 Hz frequency, patients experience an unpleasant sensation and slight edema. According to the patients, muscle contractions provoked by high amplitude (about 1,000 V/cm) and low repetition frequency (1 Hz) pulses are the most unpleasant and painful sensations. Recently, ECT using low voltage and higher repetition frequency (LVHF) has been shown to be an effective tool for inhibiting tumor growth. The aim of the present study was to optimize electric pulse amplitude and repetition frequency for LVHF ECT by sampling the different sets of pulse parameters on cell viability and permeabilization. In ECT, a reversible effect based on high permeabilization is desirable. For this purpose, we used bleomycin to evaluate the permeabilization of K562 and MIA-PACA2 cells caused by low voltage (50–150 V/cm) and higher repetition frequency (4–6 kHz) electric pulses. We show that the reversible effect with electropermeabilization of the cells caused by LVHF ECT is accessible; this interaction is more effective for electric pulses with 70 V/cm amplitude.  相似文献   

19.
Force variability during constant force tasks is directly related to oscillations below 0.5 Hz in force. However, it is unknown whether such oscillations exist in muscle activity. The purpose of this paper, therefore, was to determine whether oscillations below 0.5 Hz in force are evident in the activation of muscle. Fourteen young adults (21.07±2.76 years, 7 women) performed constant isometric force tasks at 5% and 30% MVC by abducting the left index finger. We recorded the force output from the index finger and surface EMG from the first dorsal interosseous (FDI) muscle and quantified the following outcomes: 1) variability of force using the SD of force; 2) power spectrum of force below 2 Hz; 3) EMG bursts; 4) power spectrum of EMG bursts below 2 Hz; and 5) power spectrum of the interference EMG from 10–300 Hz. The SD of force increased significantly from 5 to 30% MVC and this increase was significantly related to the increase in force oscillations below 0.5 Hz (R 2 = 0.82). For both force levels, the power spectrum for force and EMG burst was similar and contained most of the power from 0–0.5 Hz. Force and EMG burst oscillations below 0.5 Hz were highly coherent (coherence = 0.68). The increase in force oscillations below 0.5 Hz from 5 to 30% MVC was related to an increase in EMG burst oscillations below 0.5 Hz (R 2 = 0.51). Finally, there was a strong association between the increase in EMG burst oscillations below 0.5 Hz and the interference EMG from 35–60 Hz (R 2 = 0.95). In conclusion, this finding demonstrates that bursting of the EMG signal contains low-frequency oscillations below 0.5 Hz, which are associated with oscillations in force below 0.5 Hz.  相似文献   

20.
Summary We investigated the ability of pheromone-sensitive olfactory receptors of male Manduca sexta to respond to 20-ms pulses of bombykal, the major component of the conspecific pheromonal blend. Isolated pulses of bombykal elicited a burst of activity which decreased exponentially with a time constant of 160–250 ms. Trains of pulses delivered at increasing frequencies (0.5–10 Hz) elicited temporally modulated responses at up to 3 Hz. Concentration of the stimulus (1, 10, 100 ng per odor source) had a marginal effect on the temporal resolution of the receptors. Within a train, the responses to individual pulses remained constant, except for 10-Hz trains (short-term adaptation). A dose-dependent decline of responsiveness was observed during experiments (long-term adaptation). Although individual neurons may not respond faithfully to each pulse of a train, the population of receptors sampled in this study appears to be capable of encoding the onset of odor pulses at frequencies of up to at least 3 Hz.Abbreviations BAL bombykal or (E,Z)-10,12-hexadecadienal - C15 (E,Z)-11,13-pentadecadienal - HAL (E)-2-hexenal - EAG electroantennogram - P1, P2, P3 single stimulus pulses - PSTH peri-stimulus histogram - SC synchronization coefficient - 0.5, 1, 2, 3, 10 Hz stimulus trains  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号