首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
An atomic force microscope has been used to study the adhesion of Bacillus mycoides spores to a hydrophilic glass surface and a hydrophobic-coated glass surface. AFM images of spores attached to the hydrophobic-coated mica surface allowed the measurement of spore dimensions in an aqueous environment without desiccation. The spore exosporium was observed to be flexible and to promote the adhesion of the spore by increasing the area of spore contact with the surface. Results from counting procedures using light microscopy matched the density of spores observed on the hydrophobic-coated glass surface with AFM. However, no spores were observed on the hydrophilic glass surface with AFM, a consequence of the weaker adhesion of the spores at this surface. AFM was also used to quantify directly the interactions of B. mycoides spores at the two surfaces in an aqueous environment. The measurements used "spore probes" constructed by immobilizing a single spore at the apex of a tipless AFM cantilever. The data showed that stretching and sequential bond breaking occurred as the spores were retracted from the hydrophilic glass surface. The greatest spore adhesion was measured at the hydrophobic-coated glass surface. An attractive force on the spores was measured as the spores approached the hydrophobic-coated surface. At the hydrophilic glass surface, only repulsive forces were measured during the approach of the spores. The AFM force measurements were in qualitative agreement with the results of a hydrodynamic shear adhesion assay that used a spinning disk technique. Quantitatively, AFM measurements of adhesive force were up to 4 x 10(3) times larger than the estimates made using the spinning disk data. This is a consequence of the different types of forces applied to the spore in the different adhesion assays. AFM has provided some unique insights into the interactions of spores with surfaces. No other instrument can make such direct measurements for single microbiological cells.  相似文献   

3.
Single-walled carbon nanotubes are novel molecular-scale wires having excellent anti-adhesion properties with regard to platelets. On the other hand, chitosan is a partially de-acetylated derivative of chitin that has a critical role in cell attachment and growth. The aim of this study was to investigate how carbon nanotubes improve the blood biocompatibility of chitosan film. We prepared composite films with various concentrations of chitosan/carbon nanotubes (CS/CNTs) (1.3–6.3 wt%). The sample surfaces were characterized by Raman spectroscopy, X-ray photoelectron spectroscopy (XPS), atomic force microscopy (AFM), and contact angle measurements. The surface characterization revealed that the surface of the CS/CNTs composite film became more hydrophobic with increasing amounts of CNTs. Cell attachment tests using bovine aortic endothelial cells (BAECs) indicated that CS/CNTs composite films retained their cell adhesion ability. The blood compatibility of the CS/CNTs composite films was evaluated using the blood platelet adhesion and activation tests in vitro. Platelet adhesion results confirmed that platelet adhesion and the formation of a platelet network were inhibited on composite films with higher concentrations of CNTs (5.1 wt%). Our experimental results show that the novel composite film containing CS/CNTs possesses two paradoxical characteristics, namely, good adherence of endothelial cells and minimum adherence and activation of platelets, making this film a promising antithrombogenic material for use in the biomedical field.  相似文献   

4.
Atomic force microscopy (AFM) indentation has become an important technique for quantifying the mechanical properties of live cells at nanoscale. However, determination of cell elasticity modulus from the force–displacement curves measured in the AFM indentations is not a trivial task. The present work shows that these force–displacement curves are affected by indenter-cell adhesion force, while the use of an appropriate indentation model may provide information on the cell elasticity and the work of adhesion of the cell membrane to the surface of the AFM probes. A recently proposed indentation model (Sirghi, Rossi in Appl Phys Lett 89:243118, 2006), which accounts for the effect of the adhesion force in nanoscale indentation, is applied to the AFM indentation experiments performed on live cells with pyramidal indenters. The model considers that the indentation force equilibrates the elastic force of the cell cytoskeleton and the adhesion force of the cell membrane. It is assumed that the indenter-cell contact area and the adhesion force decrease continuously during the unloading part of the indentation (peeling model). Force–displacement curves measured in indentation experiments performed with silicon nitride AFM probes with pyramidal tips on live cells (mouse fibroblast Balb/c3T3 clone A31-1-1) in physiological medium at 37°C agree well with the theoretical prediction and are used to determine the cell elasticity modulus and indenter-cell work of adhesion. Electronic supplementary material  The online version of this article (doi:) contains supplementary material, which is available to authorized users.  相似文献   

5.
叶志义  范霞 《生命科学》2009,(1):156-162
细胞表面的力学性质会随着细胞所处环境的不同而发生改变,它的变化间接反映出胞内复杂的生理过程。原子力显微镜(atomic force microscope,AFM)能以高的灵敏度和分辨率检测活体细胞,通过利用赫兹模型分析力曲线可以获得细胞的弹性信息。本文简介了原子力显微镜的工作原理与工作模式,着重介绍利用AFM力曲线检测细胞弹性的方法及其在细胞运动、细胞骨架、细胞黏附、细胞病理等方面的应用成果,表明AFM已经成为细胞弹性研究中十分重要的显微技术。  相似文献   

6.
A. P. Limanskii 《Biophysics》2006,51(2):186-195
The probes for atomic force microscopy (AFM) functionalized with bovine serum albumin (BSA) were obtained; they can be used for molecular recognition studies. The procedure of modification and functionalization of the AFM probe included three stages. First, amino probes were obtained by modification in vapors of an amino silane derivative. Then, a covalent bond was formed between the surface amino groups of the probe and a homobifunctional aminoreactive crosslinker. Finally, the probe with a covalently attached crosslinker was functionalized with BSA molecules. The AFM probes were characterized by force measurements at different stages of the modification; the adhesion force and the work of adhesion force were determined. The modification process was confirmed by visualization of BSA and supercoiled pGEMEX DNA molecules immobilized on the standard amino mica and on amino mica modified with a crosslinker.  相似文献   

7.
ABSTRACT

Atomic force microscopy (AFM) increasingly has been used to analyse “receptor” function, either by using purified proteins (“molecular recognition microscopy”) or, more recently, in situ in living cells. The latter approach has been enabled by the use of a modified commercial AFM, linked to a confocal microscope, which has allowed adhesion forces between ligands and receptors in cells to be measured and mapped, and downstream cellular responses analysed. We review the application of AFM to cell biology and, in particular, to the study of ligand–receptor interactions and draw examples from our own work and that of others to show the utility of AFM, including for the exploration of cell surface functionalities. We also identify shortcomings of AFM in comparison to “standard” methods, such as receptor auto-radiography or immuno-detection, that are widely applied in cell biology and pharmacological analysis.  相似文献   

8.
Kikkawa Y  Fujita M  Abe H  Doi Y 《Biomacromolecules》2004,5(4):1187-1193
Physical properties associated with molecular mobility on the surface of thin films with 300 nm thickness for poly(lactide)s (PLAs) were studied under vacuum conditions as well as under aqueous conditions by using friction force mode atomic force microscopy (AFM). Two types of PLAs were applied for the experimental samples as uncrystallizable PLA (uc-PLA) and crystallizable PLA (c-PLA). The friction force on the surface of thin films was measured as a function of temperature to assess the surface molecular mobility both under vacuum and under aqueous conditions. A lower glass-transition temperature of the uc-PLA surface in water was detected than that under vacuum conditions. In the case of the c-PLA thin film, change in friction force was detected at a lower temperature under aqueous conditions than in vacuo. A morphological change was observed in the c-PLA thin film during heating process from room temperature to 100 degrees C by temperature-controlled AFM. The surface of the c-PLA thin film became rough due to the cold crystallization, and the crystallization of c-PLA molecules in water took place at a lower temperature than in vacuo. These friction force measurements and AFM observations suggest that molecular motion on the surface of the both uc- and c-PLA thin films is enhanced in the presence of water molecules. In addition, in situ AFM observation of the enzymatic degradation process for the c-PLA thin film crystallized at 160 degrees C was carried out in buffer solution containing proteinase K at room temperature. The amorphous region around the hexagonal crystal was eroded within 15 min. It has been suggested that the adsorption of water molecules on the PLA film surface enhances the surface molecular mobility of the glassy amorphous region of PLA and induces the enzymatic hydrolysis by proteinase K.  相似文献   

9.
Single-molecule force spectroscopy (SMFS) using the atomic force microscope (AFM) has emerged as an important tool for probing biomolecular interaction and exploring the forces, dynamics, and energy landscapes that underlie function and specificity of molecular interaction. These studies require attaching biomolecules on solid supports and AFM tips to measure unbinding forces between individual binding partners. Herein we describe efficient and robust protocols for probing RNA interaction by AFM and show their value on two well-known RNA regulators, the Rev-responsive element (RRE) from the HIV-1 genome and an adenine-sensing riboswitch. The results show the great potential of AFM–SMFS in the investigation of RNA molecular interactions, which will contribute to the development of bionanodevices sensing single RNA molecules.  相似文献   

10.
应用原子力显微镜分析猪脂肪前体细胞的分化   总被引:2,自引:0,他引:2  
脂肪形成过程中发生的异常变化与许多疾病的产生有着密切的关系。为深入了解脂肪形成的机制,利用原子力显微镜研究脂肪前体细胞向成熟脂肪细胞分化前后细胞形貌、超微结构和机械性能的变化。结果表明,脂肪前体细胞与成熟脂肪细胞在形貌上存在明显的差异。在超微结构的探测中成熟脂肪细胞表面粗糙度低于脂肪前体细胞。通过力曲线的分析得出,分化前后两种细胞的机械性质均发生改变。脂肪前体细胞在粘弹力、硬度和杨氏模量的研究中比成熟脂肪细胞都高出约20%。原子力显微镜在纳米尺度上分析脂肪前体细胞向成熟脂肪细胞分化过程中细胞膜的改变,其研究结果为进一步探讨脂肪形成机制提供可视化定量数据。  相似文献   

11.
ABSTRACT

The primary physiological function of blood platelets is to seal vascular lesions after injury and form hemostatic thrombi in order to prevent blood loss. This task relies on the formation of strong cellular-extracellular matrix interactions in the subendothelial lesions. The cytoskeleton of a platelet is key to all of its functions: its ability to spread, adhere and contract. Despite the medical significance of platelets, there is still no high-resolution structural information of their cytoskeleton. Here, we discuss and present 3-dimensional (3D) structural analysis of intact platelets by using cryo-electron tomography (cryo-ET) and atomic force microscopy (AFM). Cryo-ET provides in situ structural analysis and AFM gives stiffness maps of the platelets. In the future, combining high-resolution structural and mechanical techniques will bring new understanding of how structural changes modulate platelet stiffness during activation and adhesion.  相似文献   

12.
Gelation of gelatin under various conditions has been followed by atomic force microscopy (AFM) with the objective of understanding more fully the structure formed during the gelation process. AFM images were obtained of the structures formed from both the bulk sol and in surface films during the onset of gelation. While gelation occurred in the bulk sol, the extent of helix formation was monitored by measurements of optical rotation, and the molecular aggregation was imaged by AFM. Interfacial gelatin films formed at the air-water interface were also studied. Measurements of surface tension and surface rheology were made periodically and Langmuir-Blodgett films were drawn from the interface to allow AFM imaging of the structure of the interfacial layer as a function of time. Structural studies reveal that at low levels of helical content the gelatin molecules assemble into aggregates containing short segments of dimensions comparable to those expected for gelatin triple helices. With time larger fibrous structures appear whose dimensions suggest that they are bundles of triple helices. As gelation proceeds, the number density of fibers increases at the expense of the smaller aggregates, eventually assembling into a fibrous network. The gel structure appears to be sensitive to the thermal history, and this is particularly important in determining the structure and properties of the interfacial films. © 1998 John Wiley & Sons, Inc. Biopoly 46: 245–252, 1998  相似文献   

13.
Summary Atomic force microscopy (AFM) was used to measure the morphology and physicochemical properties of rhizobia and to probe cell-surface polymers with tips modified with soybean agglutinin (SBA). AFM measurements of the length, width, and height of Sinorhizobium fredii CCRC15769 were 1580±450, 870±70, and 270±50 nm, respectively (means±SD). Different AFM image modes revealed the morphology, adhesion, viscoelasticity, and surface roughness of rhizobia in air using the tapping operation. Force–distance relationships between SBA-terminated AFM probes and Bradyrhizobium japonicum USDA110 were recorded and the retraction curves showed an unbinding force of 106±48 pN with a loading rate of 1 nN/s in PBS containing 0.1 mM Mn2+ and 0.1 mM Ca2+ (pH 7.2). The technique of AFM provides information about the morphology and molecular interaction forces of rhizobia under physiological conditions.  相似文献   

14.
A method was developed to characterize the adhesion properties of single cells by using protein‐functionalized atomic force microscopy (AFM) probes. The quantification by force spectroscopy of the mean detachment force between cells and a gelatin‐functionalized colloidal tip reveals differences in cell adhesion properties that are not within reach of a traditional bulk technique, the washing assay. In this latter method, experiments yield semiquantitative and average adhesion properties of a large population of cells. They are also limited to stringent conditions and cannot highlight disparities in adhesion in the subset of adherent cells. In contrast, this AFM‐based method allows for a reproducible and quantitative investigation of the adhesive properties of individual cells in common cell culture conditions and allows for the detection of adhesive subpopulations of cells. These characteristics meet the critical requirements of many fields, such as the study of cancer cell migratory abilities.  相似文献   

15.
Kuo WH  Wang MJ  Chien HW  Wei TC  Lee C  Tsai WB 《Biomacromolecules》2011,12(12):4348-4356
Zwitterionic sulfobetaine methacrylate (SBMA) polymers were known to possess excellent antifouling properties due to high hydration capacity and neutral charge surface. In this study, copolymers of SBMA and acrylic acid (AA) with a variety of compositions were synthesized and were immobilized onto polymeric substrates with layer-by-layer polyelectrolyte films via electrostatic interaction. The amounts of platelet adhesion and fibrinogen adsorption were determined to evaluate hemocompatibility of poly(SBMA-co-AA)-modified substrates. Among various deposition conditions by modulating SBMA ratio in the copolymers and pH of the deposition solution, poly(SBMA(56)-co-AA(44)) deposited at pH 3.0 possessed the best hemocompatibility. This work demonstrated that poly(SBMA-co-AA) copolymers adsorbed on polyelectrolyte-base films via electrostatic interaction improve hemocompatibility effectively and are applicable for various substrates including TCPS, PU, and PDMS. Furthermore, poly(SBMA-co-AA)-coated substrate possesses great durability under rigorous conditions. The preliminary hemocompatibility tests regarding platelet adhesion, fibrinogen adsorption, and plasma coagulation suggest the potential of this technique for the application to blood-contacting biomedical devices.  相似文献   

16.
The force curve mode of the atomic force microscope (AFM) was applied to extract intrinsic membrane proteins from the surface of live cells using AFM tips modified by amino reactive bifunctional covalent crosslinkers. The modified AFM tips were individually brought into brief contact with the living cell surface to form covalent bonds with cell surface molecules. The force curves recorded during the detachment process from the cell surface were often characterized by an extension of a few hundred nanometers followed mostly by a single step jump to the zero force level. Collection and analysis of the final rupture force revealed that the most frequent force values (of the force) were in the range of 0.4–0.6 nN. The observed rupture force most likely represented extraction events of intrinsic membrane proteins from the cell membrane because the rupture force of a covalent crosslinking system was expected to be significantly larger than 1.0 nN, and the separation force of noncovalent ligand-receptor pairs to be less than 0.2 nN, under similar experimental conditions. The transfer of cell surface proteins to the AFM tip was verified by recording characteristic force curves of protein stretching between the AFM tips used on the cell surface and a silicon surface modified with amino reactive bifunctional crosslinkers. This method will be a useful addition to bionanotechnological research for the application of AFM.  相似文献   

17.
对单根DNA分子的操纵和拉伸可以直接研究DNA的弹性等力学性质. 首先通过将金沉积到云母表面制备了表面粗糙度小于0.3 nm的金膜,然后一段硫代的单链DNA (100 bases) 吸附到金膜表面. 利用原子力显微镜观察不同浓度的DNA吸附在金膜上的表面形貌. 进一步用原子力显微镜的力曲线模式拉伸DNA分子,在50%的情况下DNA可以被针尖拉伸,观察到了由于针尖和DNA分子间作用力的不同导致的多种不同力曲线.  相似文献   

18.
Boundary lubrication of articular cartilage by conformal, molecularly thin films reduces friction and adhesion between asperities at the cartilage-cartilage contact interface when the contact conditions are not conducive to fluid film lubrication. In this study, the nanoscale friction and adhesion properties of articular cartilage from typical load-bearing and non-load-bearing joint regions were studied in the boundary lubrication regime under a range of physiological contact pressures using an atomic force microscope (AFM). Adhesion of load-bearing cartilage was found to be much lower than that of non-load-bearing cartilage. In addition, load-bearing cartilage demonstrated steady and low friction coefficient through the entire load range examined, whereas non-load-bearing cartilage showed higher friction coefficient that decreased nonlinearly with increasing normal load. AFM imaging and roughness calculations indicated that the above trends in the nanotribological properties of cartilage are not due to topographical (roughness) differences. However, immunohistochemistry revealed consistently higher surface concentration of boundary lubricant at load-bearing joint regions. The results of this study suggest that under contact conditions leading to joint starvation from fluid lubrication, the higher content of boundary lubricant at load-bearing cartilage sites preserves synovial joint function by minimizing adhesion and wear at asperity microcontacts, which are precursors for tissue degeneration.  相似文献   

19.
《Journal of biomechanics》2014,47(16):3855-3861
Single-cell force spectroscopy (SCFS), an atomic force microscopy (AFM)-based assay, enables quantitative study of cell adhesion while maintaining the native state of surface receptors in physiological conditions. Human healthy and pathological red blood cells (RBCs) express a large number of surface proteins which mediate cell–cell interactions, or cell adhesion to the extracellular matrix. In particular, RBCs adhere with high affinity to subendothelial matrix laminin via the basal cell adhesion molecule and Lutheran protein (BCAM/Lu). Here, we established SCFS as an in vitro technique to study human RBC adhesion at baseline and following biochemical treatment. Using blood obtained from healthy human subjects, we recorded adhesion forces from single RBCs attached to AFM cantilevers as the cell was pulled-off of substrates coated with laminin protein. We found that an increase in the overall cell adhesion measured via SCFS is correlated with an increase in the resultant total force measured on 1 µm2 areas of the RBC membrane. Further, we showed that SCFS can detect significant changes in the adhesive response of RBCs to modulation of the cyclic adenosine monophosphate (cAMP) and protein kinase A (PKA) pathway. Lastly, we identified variability in the RBC adhesion force to laminin amongst the human subjects, suggesting that RBCs maintain diverse levels of active BCAM/Lu adhesion receptors. By using single-cell measurements, we established a powerful new method for the quantitative measurement of single RBC adhesion with specific receptor-mediated binding.  相似文献   

20.
To date, nanoscale imaging of the morphological changes and adhesion force of CD4+ T cells during in vitro activation remains largely unreported. In this study, we used atomic force microscopy (AFM) to study the morphological changes and specific binding forces in resting and activated human peripheral blood CD4+ T cells. The AFM images revealed that the volume of activated CD4+ T cells increased and the ultrastructure of these cells also became complex. Using a functionalized AFM tip, the strength of the specific binding force of the CD4 antigen-antibody interaction was found to be approximately three times that of the unspecific force. The adhesion forces were not randomly distributed over the surface of a single activated CD4+ T cell, indicated that the CD4 molecules concentrated into nanodomains. The magnitude of the adhesion force of the CD4 antigen-antibody interaction did not change markedly with the activation time. Multiple bonds involved in the CD4 antigen-antibody interaction were measured at different activation times. These results suggest that the adhesion force involved in the CD4 antigen-antibody interaction is highly selective and of high affinity.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号