首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A sensitive and convenient high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) assay for the opioid receptor agonist-antagonist butorphanol in human plasma is described. BC-2605, a cyclopropyl analogue of butorphanol, was employed as an internal standard. Butorphanol was recovered from plasma (84.4 +/- 10.9%) by liquid-liquid extraction. The mobile phase flow-rate was 0.3 ml/min and consisted of methanol-water-formic acid (90:10:0.1, v/v/v). The analytical column (4.6 x 100 mm) was packed with Partisil C(8) (5 microm). The standard curve was linear from 13.7 to 1374 pg/ml (r(2)>0.99). The lower limit of quantitation was 13.7 pg/ml. The assay was specific, accurate (% deviation from nominal concentrations were <15%), precise and reproducible (within- and between-day coefficients of variation <7%). Butorphanol in plasma was stable over 3 freeze/thaw cycles and at room temperature for 1 day. The utility of the assay was demonstrated by following butorphanol plasma concentrations in two healthy subjects for 24 h following a 1 mg intranasal dose.  相似文献   

2.
A sensitive and specific liquid chromatography/tandem mass spectrometry (LC/MS/MS) method was developed for the investigation of the pharmacokinetics of 20(R)-dammarane-3beta,12beta,20,25-tetrol (25-OH-PPD) in rat. Ginsenoside Rh(2) was employed as an internal standard. The plasma samples were pretreated by liquid-liquid extraction and analyzed using LC/MS/MS with an electrospray ionization interface. The mobile phase consisted of methanol-acetonitrile-10 mmol/l aqueous ammonium acetate (42.5:42.5:15, v:v:v), which was pumped at 0.4 ml/min. The analytical column (50 mm x 2.1 mm i.d.) was packed with Venusil XBP C8 material (3.5 microm). The standard curve was linear from 10 to 3000 ng/ml. The assay was specific, accurate (accuracy between -1.19 and 2.57% for all quality control samples), precise and reproducible (within- and between-day precisions measured as relative standard deviation were <5% and <7%, respectively). 25-OH-PPD in rat plasma was stable over three freeze-thaw cycles and at ambient temperatures for 6h. The method had a lower limit of quantitation of 10 ng/ml, which offered a satisfactory sensitivity for the determination of (25-OH-PPD) in plasma. This quantitation method was successfully applied to pharmacokinetic studies of 25-OH-PPD after both an oral and an intravenous administration to rats and the absolute bioavailability is 64.8+/-14.3%.  相似文献   

3.
An LC-MS/MS method was developed to quantitate the potential antitumor agent halofuginone in plasma. The assay uses 0.2 ml of plasma; chlorohalofuginone internal standard; acetonitrile for protein precipitation; a Phenomenex SYNERGI 4 micro Polar RP 80A (4 microm, 100 mm x 2 mm) column; an isocratic mobile phase of methanol:water:formic acid (80:20:0.02, v/v/v); and positive-ion electrospray ionization with selective reaction monitoring detection. Halofuginone eluted at approximately 2.4 min, internal standard eluted at approximately 2.9 min, and no endogenous materials interfered with their measurement. The assay was accurate, precise, and linear between 0.1 and 100 ng/ml. Halofuginone could be quantitated in dog plasma for at least 24 h after an i.v. dose of 0.1mg/kg. The assay is being used in ongoing pharmacokinetic studies of halofuginone.  相似文献   

4.
A liquid chromatography-mass spectrometry (LC/MS) assay method was developed for the quantification of PSC 833 in rat plasma, using amiodarone as internal standard (IS). Separation was achieved using a C(8) 3.5 microm (2.1 mm x 50 mm) column heated to 60 degrees C with a mobile phase consisting of acetonitrile-ammonium hydroxide 0.2% (90:10 v/v) pumped at a rate of 0.2 mL/min. Detection was accomplished by mass spectrometer using selected ion monitoring (SIM) in positive mode. An excellent linear relationship was present between peak height ratios and rat plasma concentrations of PSC 833 ranging from 10 to 5000 ng/mL (R(2)>0.99). Intra-day and inter-day coefficients of variation (CV%) were less than 15%, and mean error was less than 10% for the concentrations above the limit of quantification. The validated limit of quantification of the assay was 10 ng/mL based on 0.1 mL rat plasma. The method limit of detection, based on an average signal-to-noise (S/N) ratio of 3, was found to be 2.5 ng/mL. The assay was capable of measuring the plasma concentrations of PSC 833 in rats injected with a single dose of 5 mg/kg of the drug. PSC 833 and IS eluted within 4 min, free of interfering peaks. The method was found to be fast, sensitive, and specific for the quantification of PSC 833 in rat plasma.  相似文献   

5.
A HPLC method with UV detection at 262nm was developed to analyze inositol hexanicotinate in rat plasma. Plasma samples were extracted with an equal volume of acetonitrile, followed by dilution with mobile phase buffer (5mM phosphate buffer, pH 6.0) to eliminate any solvent effects. Inositol hexanicotinate and the internal standard (mebendazole) were separated isocratically using a mobile phase of acetonitrile/phosphate buffer (35:65, v/v, pH 6.0) at a flow rate of 1.0mL/min and a reverse-phase XTerra MS C(18) column (4.6mmx150mm, 3.5microm). The standard curve was linear over a concentration range of 1.5-100.0microg/mL of inositol hexanicotinate in rat plasma. The HPLC method was validated with intra- and inter-day precisions of 1.55-4.30% and 2.69-21.5%, respectively. The intra- and inter-day biases were -0.75 to 19.8% and 2.58-22.0%, respectively. At plasma concentrations of 1.5-100microg/mL, the mean recovery of inositol hexanicotinate was 99.6%. The results of a stability study indicated that inositol hexanicotinate was unstable in rat plasma samples, but was stable in acetonitrile extracts of rat plasma for up to 24h at 4 degrees C. The assay is simple, rapid, specific, sensitive, and reproducible and has been used successfully to analyze inositol hexanicotinate plasma concentrations in a pharmacokinetic study using the rat as an animal model.  相似文献   

6.
A liquid chromatographic–mass spectrometric (LC–MS) assay was developed and validated for the determination of itraconazole (ITZ) in rat heparinized plasma using reversed-phase HPLC combined with positive atmospheric pressure ionization (API) mass spectrometry. After protein precipitation of plasma samples (0.1 ml) with acetonitrile containing nefazodone as an internal standard (I.S.), a 50-μl aliquot of the supernatant was mixed with 100 μl of 10 mM ammonium formate (pH 4.0). An aliquot of 25 μl of the mixture was injected onto a BDS Hypersil C18 column (50×2 mm; 3 μm) at a flow-rate of 0.3 ml/min. The mobile phase comprising of 10 mM ammonium formate (pH 4) and acetonitrile (60:40, v/v) was used in an isocratic condition, and ITZ was detected in single ion monitoring (SIM) mode. Standard curves were linear (r2≥0.994) over the concentration range of 4–1000 ng/ml. The mean predicted concentrations of the quality control (QC) samples deviated by less than 10% from the corresponding nominal values; the intra-assay and inter-assay precision of the assay were within 8% relative standard deviation. Both ITZ and I.S. were stable in the injection solvent at room temperature for at least 24 h. The extraction recovery of ITZ was 96%. The validated assay was applied to a pharmacokinetic study of ITZ in rats following administration of a single dose of itraconazole (15 mg/kg).  相似文献   

7.
A sensitive high-performance liquid chromatography-tandem mass spectrometry assay for thiocoraline, an anti-tumor depsipeptide, in mouse plasma is described. Echinomycin, a quinoxaline peptide, was used as an internal standard. Thiocoraline was recovered from the mouse plasma using protein precipitation with acetonitrile and followed by solid-phase extraction of the supernatant. The mobile phase consisted of methanol (0.1% formic acid)-water (0.1% formic acid) (90:10, v/v). The analytical column was a YMC C(18). The standard curve was linear from 0.1 to 50 ng/ml (R(2)>0.99). The lower limit of quantitation was 0.1 ng/ml. The assay was specific based on the multiple reaction monitoring transitions at m/z 1157-->215 and m/z 1101-->243 for thiocoraline and the internal standard, echinomycin, respectively. The mean intra- and inter-day assay accuracies remained below 5 and 12%, respectively, for all calibration standards and quality control (QC) samples. The intra- and inter-day assay precisions were less than 11.4 and 9.5% for all QC levels, respectively. The utility of the assay was demonstrated by a pharmacokinetic study of i.v. (bolus) thiocoraline on CD-1 mice. Thiocoraline was stable in mouse plasma in an ice-water bath for 6 h and for three freeze-thaw cycles. The reconstituted thiocoraline after extraction and drying sample process was stable in the autosampler for over 24 h. The assay was able to quantify thiocoraline in plasma up to 48 h following dose. Pharmacokinetic analysis showed that thiocoraline has distinct pharmacokinetic profiling when dosed in different formulation solutions. The assay is currently used to measure thiocoraline plasma concentrations in support of a project to develop a suitable formulation with a desirable pharmacokinetic profile.  相似文献   

8.
A liquid chromatography-electrospray tandem mass spectrometry method was developed and validated to quantitate solifenacin in human plasma. The assay was based on protein precipitation with methanol and liquid chromatography performed on a pentafluorophenylpropylsilica column (50×4mm, 3μm particles), the mobile phase consisted of methanol - 100mM ammonium acetate containing 1% of formic acid (90:10, v/v). Quantification was through positive-ion mode and selected reaction monitoring at m/z 363→193 and 368→198 for solifenacin and the internal standard solifenacin-D(5), respectively. The lower limit of quantitation was 0.47ng/ml using 0.25ml of plasma and linearity was demonstrated up to 42ng/ml. Intra-assay and inter-assay precision expressed by relative standard deviation was less than 11% and inaccuracy did not exceed 11% at all levels. The assay was applied to the analysis of samples from a pharmacokinetic study.  相似文献   

9.
Abouthiouzine is a newly synthesized antithyroid agent with a proposed less adverse effects profile than other currently used drugs. A simple and rapid reversed phase high performance liquid chromatography assay was developed to determine the concentration of abouthiouzine in human plasma. The procedure involved extraction of the drug and propranolol (internal standard) from the plasma using ethylacetate. The extract was evaporated under nitrogen and the residue was constituted with the mobile phase and injected onto micro-Bondapack phenyl column (10 microm, 3.9 mm x 150 mm). The mobile phase consisted of 10 mM potassium dihydrogen phosphate buffer, acetonitrile, and methanol in the ratio of 60:25:15 (v/v/v, pH=3.0), which was delivered at a rate of 1.5 ml/min. Abouthiouzine and the internal standard were monitored using UV detection at 240 nm; the run time was less than 5 min. The detection limit of abouthiouzine is 0.5 microg/ml. The within- and between-day coefficients of variation were less than 7%. Our method has been successfully used to measure abouthiouzine plasma concentrations in a rabbit model following an intravenous administration of the drug.  相似文献   

10.
A rapid and sensitive LC-MS-MS method for the determination of huperzine A in dog plasma using huperzine B as internal standard has been developed and validated. The analyte and internal standard were extracted from plasma using n-hexane-dichloromethane-2-propanol (300:150:15, v/v/v), chromatographed on a C(18) column (5 microm, 50 mm x 4.6 mm i.d.) with a mobile phase consisting of acetonitrile-methanol-10mM ammonium acetate (35:40:25, v/v/v), and detected using a tandem mass spectrometer with a TurboIonSpray ionization interface. The run time was only 2 min. The assay was linear over the concentration range 0.05-20 ng/ml and intra- and inter-day precision over this range were <5.3% with good accuracy. The limit of detection in plasma was 0.01 ng/ml. The method was successfully applied to define plasma concentration-time curves of huperzine A in dogs after the last dose of an intramuscular injection (10 microg/kg per day for 15 days) of a sustained-release formulation of huperzine A.  相似文献   

11.
A sensitive and rapid LC-MS/MS assay for the quantitative determination of 5-methylindirubine (5-MI) in murine plasma is described. A 50-microL-murine plasma aliquot was spiked with an internal standard, indirubine-3-monoxime (IMO), and extracted with 1.25 mL diethyl ether. Dried extracts were reconstituted in methanol-water (8:2, v/v) and 10 microL-volumes were injected onto the HPLC system. Separation was achieved on a Gemini C18 column (150 mm x 2.1 mm ID, particle size 5 microm) using an alkaline eluent (10 mM ammonium hydroxide-methanol (5:95, v/v)). Detection was performed by negative ion electrospray followed by tandem mass spectrometry. The assay quantifies 5-MI in a range from 1 to 500 ng/mL using 50 microL of murine EDTA plasma samples. Validation results demonstrate that 5-MI concentrations can be accurately and precisely quantified in murine plasma. This assay is used to support pre-clinical pharmacologic studies with 5-MI.  相似文献   

12.
A sensitive, specific and precise HPLC–UV assay was developed to quantitate cocaine (COC) and its metabolites benzoylecgonine (BE), norcocaine (NC) and cocaethylene (CE) in rat plasma. After adding 50 μl of the internal standard solution (bupivacaine, 8 μg/ml) and 500 μl of Sørensen's buffer (pH 6) to 100 μl of rat plasma sample, the mixture was extracted with 10 ml of chloroform. The organic layer was transferred to a clean test tube and was evaporated under nitrogen. The residue was reconstituted in 100 μl of mobile phase and 35 μl was injected onto the HPLC column. The mobile phase consisted of methanol–acetonitrile–50 mM monobasic ammonium phosphate (5:7:63, v/v/v) and was maintained at a flow-rate of 0.4 ml/min. Separation of COC and its metabolites was achieved using a Supelcosil ABZ+plus deactivated reversed-phase column (250×2.1 mm I.D., 5 μm). Calibration curves were linear over the range of 25–5000 ng/ml for COC and its three metabolites. The absolute extraction efficiencies for BE, COC, NC, CE and bupivacaine were 56.6%, 78.6%, 61.1%, 76.4% and 67.0%, respectively. COC and its metabolites were stable in mobile phase for 24 h at room temperature and in rat plasma for 2 weeks at −20°C. The limits of detection for BE, COC, NC and CE were 20, 24, 15 and 12.9 ng/ml, respectively. These values correspond to 0.70, 0.84, 0.525 and 0.452 ng of the according compound being injected on column. The within-day coefficient of variation for the four compounds ranged from 3.0% to 9.9% while the between-day precision varied from 3.6% to 14%. This method was used to analyze rat plasma samples after administration of COC alone and in combination with alcohol. The pharmacokinetic profiles of COC and its metabolites in these rats are also described.  相似文献   

13.
A reversed-phase high-performance liquid chromatographic (HPLC) method with ultraviolet (UV) detection was developed and validated for the quantification of 6-deoxy-6-demethyl-4-dedimethylamino-tetracycline (COL-3), a matrix metalloproteinase (MMPs) inhibitor, in rat serum. This simple, sensitive, rapid and reproducible assay involved a preliminary serum deproteinization by adding a mixture of acetonitrile-methanol-0.5 M oxalic acid (70:20:10 (v/v)), as the combined precipitant and metal blocking agent, into serum samples (2:1 (v/v)). An aliquot (20 microl) of the supernatant was injected into the HPLC system linked to a Waters XTerra RP(18) column (150 mm x 4.6 mm i.d., particle size 5 microm). The compound was eluted by a mixture of acetonitrile-methanol-0.01 M oxalic acid (40:10:50 (v/v), pH 2.00), as the mobile phase, and detected at the wavelength of 350 nm. The total running time was 10 min. The low and high concentration calibration curves were linear in the range of 50-1200 ng/ml and 1200-12,000 ng/ml, respectively. The intra- and inter-day coefficients of variation at three quality control concentrations of 100, 1200, and 12,000 ng/ml were all less than 6%, while the percent error ranged from -2.5 to 6.6%. The limit of quantitation (LOQ) for COL-3 in serum was 50 ng/ml. This assay was successfully employed to study the serum concentration-time profiles of COL-3 after its intravenous and oral administration in rats. The method with some minor modifications in sample pretreatment was also applicable to the determination of the concentrations of COL-3 in rat bile, urine and feces.  相似文献   

14.
A reversed-phase high-performance liquid chromatographic method for the determination of sinefungin, a new antiprotozoal drug, in rat plasma has been developed and validated. Sample preparation was performed at 4°C by deproteinization with acetonitrile. Vidarabine was used as an internal standard. Both sinefungin and vidarabine were separated on a C18 column with a mobile phase of ammmonium dihydrogenphosphate-acetonitrile (95:5, v/v) and detected by ultraviolet absorbance at 260 nm. Recoveries of sinefungin from plasma were 75 ± 3.2% and 81 ± 4.8% following dosage at concentrations of 10 μg/ml and 30 μ/ml, respectively. Using 25- μl of rat plasma the limit of quantitation was 1 μg/ml sinefungin, and the assay was linear from 1 to 30 μg/ml. This method appears sensitive enough to be used in further pharmacokinetic studies of sinefungin in animal models.  相似文献   

15.
A sensitive and specific liquid chromatography electrospray ionization mass spectrometry (LC-ESI-MS) method has been developed and validated for the identification and quantification of lipoic acid (LA) in human plasma. LA and the internal standard, naproxen, were extracted from a 500 microl plasma sample by one-step deproteination using acetonitrile. Chromatographic separation was performed on a Zorbax SB-C(18) Column (100 mmx3.0mm i.d. with 3.5 microm particle size) with the mobile phase consisting of acetonitrile and 0.1% acetic acid (pH 4, adjusted with ammonia solution) (65:35, v/v), and the flow rate was set at 0.3 ml/min. Detection was performed on a single quadrupole mass spectrometer by selected ion monitoring (SIM) mode via electrospray ionization (ESI) source. The method was linear over the concentration range of 5-10,000 ng/ml for LA. The intra- and inter-day precisions were less than 7% and accuracy ranged from -7.87 to 9.74% at the LA concentrations tested. The present method provides a relatively simple and sensitive assay with short turn-around time. The method has been successfully applied to a clinical pharmacokinetic study of LA in 10 healthy subjects.  相似文献   

16.
A high-performance liquid chromatographic method using liquid-liquid extraction was developed for the determination of 1-(3-fluoro-4-hydroxy-5-mercaptomethyl-tetrahydrofuran-2-yl)-5-methyl-1H-pyrimidine-2,4-dione (l-FMAUS; I) in rat plasma and urine. A 100 microl aliquot of distilled water containing l-cysteine (100 mg/ml) was added to a 100 microl aliquot of biological sample. l-Cysteine was employed to protect binding between the 5'-thiol of I and protein in the biological sample. After vortex-mixing for 30s and adding a 50 microl aliquot of the mobile phase containing the internal standard (10 microg/ml of 3-aminophenyl sulfone), 1 ml of ethyl acetate was used for extraction. After vortex-mixing, centrifugation, and evaporating the ethyl acetate, the residue was reconstituted with a 100 microl aliquot of the mobile phase. A 50 microl aliquot was injected onto a C(18) reversed-phase column. The mobile phases, 50 mM KH(2)PO(4) (pH = 2.5):acetonitrile (85:15, v/v) for rat plasma and 50 mM KH(2)PO(4) (pH 2.5):acetonitrile:methanol (85:10:5, v/v/v) for urine samples, were run at a flow-rate of 1.2 ml/min. The column effluent was monitored by an ultraviolet detector set at 265 nm. The retention times for I and the internal standard were approximately 9.7 and 12.5 min, respectively, in plasma samples and the corresponding values in urine samples were 16.8 and 14.9 min. The quantitation limits of I in rat plasma and urine were 0.1 and 0.5 microg/ml, respectively.  相似文献   

17.
A sensitive and selective liquid chromatographic assay for determining the non-peptide endothelin A receptor antagonist PD 156707 (I) in rat plasma has been developed and validated. The analyte was isolated from matrix by solid-phase extraction. Liquid chromatographic separation was achieved isocratically ona 3.2 mm I.D., ODS column with a mobile hase of acetonitrile-ammonium phosphate (50 mM, pH 3.5) (44:56, v/v). Column effluent was monitored fluorometrically. Peak-height ratios (analyte/IS) were proportional to I concentrations in rat plasma from 25 to 1000 ng/ml. Assay precision and accuracy for I, based on quality controls, was 9.5% relative standard deviation, with relative error of ±6.5%. The quantitation limit was 25 ng/ml for a 200-μl sample aliquot.  相似文献   

18.
A rapid, selective and sensitive high-performance liquid chromatographic method with spectrophotometric detection was developed for the determination of clarithromycin in human plasma. Liquid-liquid extraction of clarithromycin and norverapamil (as internal standard) from plasma samples was performed with n-hexane/1-butanol (98:2, v/v) in alkaline condition followed by back-extraction into diluted acetic acid. Chromatography was carried out using a CN column (250 mm x 4.6 mm, 5 microm) under isocratic elution with acetonitrile-50 mM aqueous sodium dihydrogen phosphate (32:68, v/v), pH 4.5. Detection was made at 205 nm and analyses were run at a flow-rate of 1.0 ml/min at 40 degrees C. The analysis time was less than 11 min. The method was specific and sensitive with a quantification limit of 31.25 ng/ml and a detection limit of 10 ng/ml in plasma. The mean absolute recovery of clarithromycin from plasma was 95.9%, while the intra- and inter-day coefficient of variation and percent error values of the assay method were all less than 9.5%. Linearity was assessed in the range of 31.25-2000 ng/ml in plasma with a correlation coefficient of greater than 0.999. The method was used to analyze several hundred human plasma samples for bioavailability studies.  相似文献   

19.
A highly sensitive HPLC method with automated column switching was developed for the simultaneous determination of endogenous levels of 13-cis-retinoic acid (isotretinoin), all-trans-retinoic acid (tretinoin) and their 4-oxo metabolites in plasma samples from man, Cynomolgus monkey, rabbit, rat and mouse. Plasma (0.4 ml) was deproteinated by adding ethanol (1.5 ml) containing the internal standard acitretin. After centrifugation, 1.4 ml of the supernatant were directly injected onto the precolumn packed with LiChrospher 100 RP-18 (5 μm). 1.25% ammonium acetate and acetic acid-ethanol (8:2, v/v) was used as mobile phase during injection and 1% ammonium acetate and 2% acetic acid-ethanol (102:4, v/v) was added, on-line, to decrease the elution strength of the injection solution. After backflush purging of the precolumn, the retained components were transferred to the analytical column in the backflush mode, separated by gradient elution and detected at 360 nm. Two coupled Superspher 100 RP-18 endcapped columns (both 250×4 mm) were used for the separation, together with a mobile phase consisting of acetonitrile-water-10% ammonium acetate-acetic acid: (A) 600:300:60:10 (v/v/v/v), (B) 950:20:5:20 (v/v/v/v), and (C) 990:5:0:5 (v/v/v/v). The method was linear in the range 0.3–100 ng/ml, at least, with a quantification limit of 0.3 ng/ml. The mean recoveries from human plasma were 93.2%–94.4% and the mean inter-assay precision was 2.8%–3.2% (range 0.3–100 ng/ml). Similar results were obtained for animal plasma. The analytes were found to be stable in the plasma of all investigated species stored at −20°C for 4.3 months and at −80°C for 9 months, at least. At this temperature, human plasma samples were even stable for 2 years. The method was successfully applied to more than 6000 human and 1000 animal plasma samples from clinical and toxicokinetic studies. Endogenous levels determined in control patients and pregnant women were similar to published data from volunteers.  相似文献   

20.
A sensitive, specific and fast high-performance liquid chromatography/tandem mass spectrometry (HPLC-MS/MS) assay for the determination of vinorelbine in mouse and human plasma is presented. A 200 microL aliquot was extracted with solid-phase extraction (SPE) using Bond-Elut C(2) cartridges. Dried extracts were reconstituted in 100 microL 1 mM ammonium acetate pH 10.5-acetonitrile-methanol (21:9:70, v/v/v) containing the internal standard vintriptol (100 ng/mL) and 10 microL volumes were injected onto the HPLC system. Separation was achieved on a 50 mm x 2.0 mm i.d. Gemini C(18) column using isocratic elution with 1 mM ammonium acetate pH 10.5-acetonitrile-methanol (21:9:70, v/v/v) at a flow rate of 0.4 mL/min. HPLC run time was only 5 min. Detection was performed using positive ion electrospray ionization followed by tandem mass spectrometry (ESI-MS/MS). The assay quantifies vinorelbine from 0.1 to 100 ng/mL using human plasma sample volumes of 200 microL. With this method vinorelbine can be measured in mouse plasma samples when these samples are diluted eight times in control human plasma. Calibration samples prepared in control human plasma can be used for the quantification of the drug. The lower limit of quantification in mouse plasma is 0.8 ng/mL. This assay is used to support preclinical and clinical pharmacologic studies with vinorelbine.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号