首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 250 毫秒
1.
In this study, we compared the traditional murine model with renal pedicle clamp with models that clamped the renal artery or vein alone as well as to a whole body ischemia-reperfusion injury (WBIRI) model. Male C57BL/6J mice underwent either clamping of the renal artery, vein, or both (whole pedicle) for 30 or 45 min followed by reperfusion, or 10 min of cardiac arrest followed by resuscitation up to 24 h. After 30 min of ischemia, the mice with renal vein clamping showed the mostly increased serum creatinine and the most severe renal tubule injury. After 45 min of ischemia, all mice with renal vasculature clamping had a comparable increase in serum creatinine but the renal tubule injury was most severe in renal artery-clamped mice. Renal arterial blood flow was most decreased in mice with a renal vein clamp compared with a renal artery or pedicle clamp. A 30-or 45-min renal ischemia time led to a significant increase in the protein level of interleukin-6, keratinocyte-derived chemokine (KC), and granular colony-stimulating factor in the ischemic kidney, but the KC was the highest in the renal pedicle-clamped kidney and the lowest in the renal vein-clamped kidney. Of note, 10 min of WBIRI led to kidney dysfunction and structural injury, although less than longer time clamping of isolated renal vasculature. Our data demonstrate important differences in ischemic AKI models. Understanding these differences is important in designing future experimental studies in mice as well as clinical trials in humans.  相似文献   

2.
Vascular cross-clamping is applied in many cardiovascular surgeries such as coronary bypass, aorta repair and valve procedures. Experimental studies have found that clamping of various degrees caused damage to arteries. This study examines the effects of popular clamps on vessel wall. Models of the aorta and clamp were created in Computer Assisted Design and Finite Element Analysis packages. The vessel wall was considered as a non-linear anisotropic material while the fluid was simulated as Newtonian with pulsatile flow. The clamp was applied through displacement time function. Fully coupled two-way solid–fluid interaction models were developed. It was found that the clamp design significantly affected the stresses in vessel wall. The clamp with a protrusion feature increased the overall Von Mises stress by about 60% and the compressive stress by more than 200%. Interestingly, when the protrusion clamp was applied, the Von Mises stress at the lumen (endothelium) side of artery wall was about twice that of the outer wall. This ratio was much higher than that of the plate-like clamp which was about 1.3. The flow reversal process was demonstrated during clamping. Vibrations, flow and wall shear stress oscillations were detected immediately before total vessel occlusion. The commonly used protrusion clamp increased stresses in vessel wall, especially the compressive stress. This design also significantly increased the stresses on endothelium, detrimental to vessel health. The present findings are relevant to surgical clamp design as well as the transient mechanical loading on the endothelium and potential injury. The deformation and stress analysis may provide valuable insights into the mode of tissue injury during cross-clamping.  相似文献   

3.
Robotic surgery is an attractive, minimally invasive and high precision alternative to conventional surgical procedures. However, it lacks the natural touch and force feedback that allows the surgeon to control safe tissue manipulation. This is an important problem in standard surgical procedures such as clamping, which might induce severe tissue damage. In complex, heterogeneous, large deformation scenarios, the limits of the safe loading regime beyond which tissue damage occurs are unknown. Here, we show that a continuum damage model for arteries, implemented in a finite element setting, can help to predict arterial stiffness degradation and to identify critical loading regimes. The model consists of the main mechanical constituents of arterial tissue: extracellular matrix, collagen fibres and smooth muscle cells. All constituents are allowed to degrade independently in response to mechanical overload. To demonstrate the modularity and portability of the proposed model, we implement it in a commercial finite element programme, which allows to keep track of damage progression via internal variables. The loading history during arterial clamping is simulated through four successive steps, incorporating residual strains. The results of our first prototype simulation demonstrate significant regional variations in smooth muscle cell damage. In three additional steps, this damage is evaluated by simulating an isometric contraction experiment. The entire finite element simulation is finally compared with actual in vivo experiments. In the short term, our computational simulation tool can be useful to optimise surgical tools with the goal to minimise tissue damage. In the long term, it can potentially be used to inform computer-assisted surgery and identify safe loading regimes, in real time, to minimise tissue damage during robotic tissue manipulation.  相似文献   

4.
Stress and deformation in arterial wall tissue are factors which may influence significantly its response and evolution. In this work we develop models based on nonlinear elasticity and finite element numerical solutions for the mechanical behaviour and the remodelling of the soft tissue of arteries, including anisotropy induced by the presence of collagen fibres. Remodelling and growth in particular constitute important features in order to interpret stenosis and atherosclerosis. The main object of this work is to model accurately volumetric growth, induced by fluid shear stress in the intima and local wall stress in arteries with patient-specific geometry and loads. The model is implemented in a nonlinear finite element setting which may be applied to realistic 3D geometries obtained from in vivo measurements. The capabilities of this method are demonstrated in several examples. Firstly a stenotic process on an idealised geometry induced by a non-uniform shear stress distribution is considered. Following the growth of a right coronary artery from an in vivo reconstructed geometry is presented. Finally, experimental measurements for growth under hypertension for rat carotid arteries are modelled.  相似文献   

5.
During free flap transfer, the surgeon may decide to begin with repair of the artery or the vein(s) and to unclamp the first vessel as soon as repair is completed or maintain the clamping of both vessels until completion of all repairs. Complications can lead to prolonged clamping times, potentially increasing the risk of tissue ischemia, vascular damage, and thrombosis. The goals of the present study were to determine whether the sequence of vessel repair and the duration of clamping affect the success of free flap transfer in cases requiring prolonged clamping. Sixty abdominal fasciocutaneous free flaps based on the superficial inferior epigastric vessels were created in Sprague-Dawley rats. To model clinical situations in which prolonged clamping is necessary, the study used a 1-hour delay before the repair of the second vessel. Flaps were randomized into four groups. In group I (n = 15), the artery was repaired first, and the arterial clamp was removed immediately to allow arterial inflow. In group II (n = 15), the arterial repair was first, and the arterial clamp was maintained until completion of venous repair. In group III (n = 15), venous repair was first, with venous clamping maintained until completion of the arterial repair. In group IV (n = 15), initial venous repair was followed by immediate unclamping, before arterial repair. On release of all clamps, the patency of arteries and veins was confirmed immediately and after 1 hour using a "milking" test. On the fifth postoperative day, each flap was assessed for necrosis and for patency of the anastomoses. Of 15 flaps in each group, five (33 percent) failed in group I, four (27 percent) failed in groups II and III, and six (40 percent) failed in group IV. Differences between groups were not statistically significant (p = 0.8). These results demonstrate that in cases requiring prolonged occlusive clamping (2 to 3 hours), factors such as venous congestion, possible clamp injury, and presence of static blood in contact with the new anastomosis have relatively equivalent contributions to the risk of failure. Accordingly, no advantage seems to be gained by beginning with the artery or the vein or by using early or delayed unclamping of the first vessel repaired.  相似文献   

6.
Since their first introduction, stents have revolutionised the treatment of atherosclerosis; however, the development of in-stent restenosis still remains the Achilles' heel of stent deployment procedures. Computational modelling can be used as a means to model the biological response of arteries to different stent designs using mechanobiological models, whereby the mechanical environment may be used to dictate the growth and remodelling of vascular cells. Changes occurring within the arterial wall due to stent-induced mechanical injury, specifically changes within the extracellular matrix, have been postulated to be a major cause of activation of vascular smooth muscle cells and the subsequent development of in-stent restenosis. In this study, a mechanistic multi-scale mechanobiological model of in-stent restenosis using finite element models and agent-based modelling is presented, which allows quantitative evaluation of the collagen matrix turnover following stent-induced arterial injury and the subsequent development of in-stent restenosis. The model is specifically used to study the influence of stent deployment diameter and stent strut thickness on the level of in-stent restenosis. The model demonstrates that there exists a direct correlation between the stent deployment diameter and the level of in-stent restenosis. In addition, investigating the influence of stent strut thickness using the mechanobiological model reveals that thicker strut stents induce a higher level of in-stent restenosis due to a higher extent of arterial injury. The presented mechanobiological modelling framework provides a robust platform for testing hypotheses on the mechanisms underlying the development of in-stent restenosis and lends itself for use as a tool for optimisation of the mechanical parameters involved in stent design.  相似文献   

7.
Arterial stiffness is highly correlated with the functions of the artery and may serve as an important diagnostic criterion for some cardiovascular diseases. To date, it remains a challenge to quantitatively assess local arterial stiffness in a non-invasive manner. To address this challenge, we investigated the possibility of determining arterial stiffness using the guided circumferential wave (GCW) induced in the arterial wall by a focused acoustic radiation force. The theoretical model for the dispersion analysis of the GCW is presented, and a finite element model has been established to calculate the dispersion curve. Our results show that under described conditions, the dispersion relations of the GCW are basically independent of the curvature of the arterial wall and can be well-described using the Lamb wave (LW) model. Based on this conclusion, an inverse method is proposed to characterize the elastic modulus of artery. Both numerical experiments and phantom experiments had been performed to validate the proposed method. We show that our method can be applied to the cases in which the artery has local stenosis and/or the geometry of the artery cross-section is irregular; therefore, this method holds great potential for clinical use.  相似文献   

8.
Ischemia-reperfusion induced acute kidney injury (IR-AKI) is widely used as a model of AKI in mice, but results are often quite variable with high, often unreported mortality rates that may confound analyses. Bilateral renal pedicle clamping is commonly used to induce IR-AKI, but differences between effective clamp pressures and/or renal responses to ischemia between kidneys often lead to more variable results. In addition, shorter clamp times are known to induce more variable tubular injury, and while mice undergoing bilateral injury with longer clamp times develop more consistent tubular injury, they often die within the first 3 days after injury due to severe renal insufficiency. To improve post-injury survival and obtain more consistent and predictable results, we have developed two models of unilateral ischemia-reperfusion injury followed by contralateral nephrectomy. Both surgeries are performed using a dorsal approach, reducing surgical stress resulting from ventral laparotomy, commonly used for mouse IR-AKI surgeries. For induction of moderate injury BALB/c mice undergo unilateral clamping of the renal pedicle for 26 min and also undergo simultaneous contralateral nephrectomy. Using this approach, 50-60% of mice develop moderate AKI 24 hr after injury but 90-100% of mice survive. To induce more severe AKI, BALB/c mice undergo renal pedicle clamping for 30 min followed by contralateral nephrectomy 8 days after injury. This allows functional assessment of renal recovery after injury with 90-100% survival. Early post-injury tubular damage as well as post injury fibrosis are highly consistent using this model.  相似文献   

9.
The mismatch between the elastic properties and initial geometry of a host artery and an implanted stent or graft cause significant stress concentration at the zones close to junctions. This may contribute to the often observed intimal hyperplasia, resulting in late lumen loss and eventual restenosis. This study proposes a mathematical model for stress-induced thickening of the arterial wall at the zones close to an implanted stent or graft. The host artery was considered initially as a cylindrical shell with constant thickness that was clamped to the stent or graft, which was assumed to be non-deformable in the circumferential direction. It was assumed that the abnormal circumferential and axial stresses due to the bending of the arterial wall cause wall thickening that tends to restore the stress state close to that existing far from the junction. The linear equations of a cylindrical shell with variable thickness were coupled to an evolution equation for the wall thickness. These equations were solved numerically and a parametric study was performed using finite difference method and explicit time step. The results show that the remodeling process is self-limiting and leads to local thickening that gradually decreases with distance from the edge of the stent/graft. Model predictions were tested against morphological findings existing in the literature. Recommendations on stent designs that reduce stress concentrations are discussed.  相似文献   

10.
11.
The endothelial cells (ECs) lining a blood vessel wall are exposed to both the wall shear stress (WSS) of blood flow and the circumferential strain (CS) of pulsing artery wall motion. These two forces and their interaction are believed to play a role in determining remodeling of the vessel wall and development of arterial disease (atherosclerosis). This study focused on the WSS and CS dynamic behavior in a compliant model of a coronary artery taking into account the curvature of the bending artery and physiological radial wall motion. A three-dimensional finite element model with transient flow and moving boundaries was set up to simulate pulsatile flow with physiological pressure and flow wave forms characteristic of the coronary arteries. The characteristic coronary artery curvature and flow conditions applied to the simulation were: aspect ratio (lambda) = 10, diameter variation (DV) = 6 percent, mean Reynolds number (Re) = 150, and unsteadiness parameter (alpha) = 3. The results show that mean WSS is about 50 percent lower on the inside wall than the outside wall while WSS oscillation is stronger on the inside wall. The stress phase angle (SPA) between CS and WSS, which characterizes the dynamics of the mechanical force pattern applied to the endothelial cell layer, shows that CS and WSS are more out of phase in the coronaries than in any other region of the circulation (-220 deg on the outside wall, -250 deg on the inside wall). This suggests that in addition to WSS, SPA may play a role in localization of coronary atherosclerosis.  相似文献   

12.
Dissecting aneurysm is the condition produced by separation of the layers of the arterial wall by circulating blood. Although rare, the coexistence of aortic dissection and aberrant right subclavian artery may be catastrophic. In this study we report the endovascular treatment of a patient with thoracic aorta dissection associated with aberrant right subclavian artery. Aortic clamping proximal to the left subclavian artery in a patient with an aberrant right subclavian artery slows or eliminates flow to both vertebral arteries. Endovascular repair eliminates the complications associated with aortic clamping during surgical repair in the presence of an aberrant right subclavian artery; therefore, it should be considered the treatment of choice in this situation.  相似文献   

13.
Two different stent configurations (i.e. the well known Palmaz–Schatz (PS) and a new stent configuration) are mechanically investigated. A finite element model was used to study the two geometries under combining loads and a computational fluid dynamic model based on fluid structure interaction was developed investigating the plaque and the artery wall reactions in a stented arterial segment. These models determine the stress and displacement fields of the two stents under internal pressure conditions. Results suggested that stent designs cause alterations in vascular anatomy that adversely affect arterial stress distributions within the wall, which have impact in the vessel responses such as the restenosis. The hemodynamic analysis shows the use of new stent geometry suggests better biofluid mechanical response such as the deformation and the progressive amount of plaque growth.  相似文献   

14.
This study was done to determine whether microemboli are produced by an arterial anastomosis. Direct in vivo observations were made in an isolated microcirculatory bed lying directly downstream from a newly made anastomosis. The tissue used was the isolated rat cremaster muscle, a new experimental model. The vessel anastomosed was the external iliac artery. Following anastomosis, microemboli were clearly observed in eight of eight animals during the first 30 minutes after clamp release. Embolic events were sometimes of impressive magnitude and in one case were associated with cessation of blood flow throughout the preparation. No microemboli were observed in eight of eight animals subjected only to dissection of the cremaster, nor were any observed in eight of eight animals in which the isolated cremaster was subjected only to 2 hours of clamp ischemia. These findings may be significant in explaining perturbations to blood flow following free-tissue transfer and instances of partial tissue necrosis following apparently successful arterial repair. These findings also identify an important factor (microemboli) to be considered in research on reperfusion injury.  相似文献   

15.
To investigate the mechanical effects of tissue responses, such as remodelling, in the arteries of the elderly, it is important to evaluate stress in the intimal layer. In this study, we investigated a novel technique to evaluate the effect of layer-specific characteristics on stress in the arterial wall in an elderly subject. We used finite element analysis of a segment of carotid artery with intimal thickening, incorporating stress-released geometries and the stress–strain relationships for three separate wall layers. We correlated the stress–strain relationships and local curvatures of the layers with the stress on the arterial wall under physiological loading. The simulation results show that both the stress–strain relationship and the local curvature of the innermost stress-released layer influence the circumferential stress and its radial gradient. This indicates that intimal stress is influenced significantly by location-dependent intimal remodelling. However, further investigation is needed before conclusive inferences can be drawn.  相似文献   

16.
Voltage-clamp of excitable membrane allows the measurement of membrane currents associated with electrical potential changes across the membrane. However, it has been impossible in practice to apply the conventional analog feedback voltageclamp circuits to single electrode voltage clamping in central neurons. The reason for this is that the feedback system becomes unstable because of the positive feedback required for compensation of capacitative loss through the wall of the microelectrode. Park et al. (1981) proposed a new iterative technique to solve this problem. It requires that the potential to be clamped repeats itself with little or no change. The amount of current needed to clamp the membrane potential is not determined at once, but in a step-wise, trial and error fashion in the course of a set of repetitions. Since the feedback loop is open in real time, the system has great stability, and this advantage can be exploited in single electrode preparations. The computation algorithm which calculates the current waveform based on the voltage deviation during the last trial is the central part of the iterative voltage-clamp system. In this paper, we propose a new algorithm, which has several theoretical and practical advantages over the original one proposed by Park et al. First, two parameters used in the new algorithm are predetermined by a current-clamp experiment. Second, the speed of convergence of the new algorithm is faster than that of the Park's original algorithm. This was shown by computer simulation of iterative voltage clamp of artificial membrane following Hodgkin-Huxley equations for squid axon membrane and Rall's compartment model for a neuron with dendrites. Finally, we offer proof that the new algorithm is certain to converge for the general cases of voltage-clamp experiments with active membrane properties, synaptic membranes, etc. Consequently, the new algorithm for iterative voltage clamp is very suitable for single electrode voltage clamp in the central neurons. The new algorithm has been successfully applied to voltage-clamp experiments on rubrospinal neurons of cats (Tsukahara, Murakami, Kawato, Oda, and Etoh, in preparation).  相似文献   

17.
The cut-open oocyte Vaseline gap (COVG) voltage clamp technique allows for analysis of electrophysiological and kinetic properties of heterologous ion channels in oocytes. Recordings from the cut-open setup are particularly useful for resolving low magnitude gating currents, rapid ionic current activation, and deactivation. The main benefits over the two-electrode voltage clamp (TEVC) technique include increased clamp speed, improved signal-to-noise ratio, and the ability to modulate the intracellular and extracellular milieu.Here, we employ the human cardiac sodium channel (hNaV1.5), expressed in Xenopus oocytes, to demonstrate the cut-open setup and protocol as well as modifications that are required to add voltage clamp fluorometry capability.The properties of fast activating ion channels, such as hNaV1.5, cannot be fully resolved near room temperature using TEVC, in which the entirety of the oocyte membrane is clamped, making voltage control difficult. However, in the cut-open technique, isolation of only a small portion of the cell membrane allows for the rapid clamping required to accurately record fast kinetics while preventing channel run-down associated with patch clamp techniques.In conjunction with the COVG technique, ion channel kinetics and electrophysiological properties can be further assayed by using voltage clamp fluorometry, where protein motion is tracked via cysteine conjugation of extracellularly applied fluorophores, insertion of genetically encoded fluorescent proteins, or the incorporation of unnatural amino acids into the region of interest1. This additional data yields kinetic information about voltage-dependent conformational rearrangements of the protein via changes in the microenvironment surrounding the fluorescent molecule.  相似文献   

18.
《Journal of biomechanics》2014,47(16):3868-3875
Tortuous arteries associated with aneurysms have been observed in aged patients with atherosclerosis and hypertension. However, the underlying mechanism is poorly understood. The objective of this study was to determine the effect of aneurysms on arterial buckling instability and the effect of buckling on aneurysm wall stress. We investigated the mechanical buckling and post-buckling behavior of normal and aneurysmal carotid arteries and aorta’s using computational simulations and experimental measurements to elucidate the interrelationship between artery buckling and aneurysms. Buckling tests were done in porcine carotid arteries with small aneurysms created using elastase treatment. Parametric studies were done for model aneurysms with orthotropic nonlinear elastic walls using finite element simulations. Our results demonstrated that arteries buckled at a critical buckling pressure and the post-buckling deflection increased nonlinearly with increasing pressure. The presence of an aneurysm can reduce the critical buckling pressure of arteries, although the effect depends on the aneurysm’s dimensions. Buckled aneurysms demonstrated a higher peak wall stress compared to unbuckled aneurysms under the same lumen pressure. We conclude that aneurysmal arteries are vulnerable to mechanical buckling and mechanical buckling could lead to high stresses in the aneurysm wall. Buckling could be a possible mechanism for the development of tortuous aneurysmal arteries such as in the Loeys–Dietz syndrome.  相似文献   

19.
Voltage clamping with a single microelectrode.   总被引:6,自引:0,他引:6  
A technique is described which allows neurons to be voltage clamped with a single microelectrode, and the advantages of this circuit with respect to conventional bridge techniques are discussed. In this circuit, the single microelectrode is rapidly switched from a current passing to a recording mode. The circuitry consists of: (1) an electronic switch; (2) a high impedance, ultralow input capacity amplifier; (3) a sample-and-hold module; (4) conventional voltage clamping circuitry. The closed electronic switch allows current to flow through the electrode. The switch then opens, and the electrode is in a recording mode. The low input capacity of the preamplifier allows the artifact from the current pulse to rapidly abate, after which time the circuit samples the membrane potential. This cycle is repeated at rates up to 10 kHz. The voltage clamping amplifier senses the output of the sample-and-hold module and adjusts the current pulse amplitude to maintain the desired membrane potential. The system was evaluated in Aplysia neurons by inserting two microelectrodes into a cell. One electrode was used to clamp the cell and the other to independently monitor membrane potential at a remote location in the soma.  相似文献   

20.
The present study illustrates a possible methodology to investigate drug elution from an expanded coronary stent. Models based on finite element method have been built including the presence of the atherosclerotic plaque, the artery and the coronary stent. These models take into account the mechanical effects of the stent expansion as well as the effect of drug transport from the expanded stent into the arterial wall. Results allow to quantify the stress field in the vascular wall, the tissue prolapse within the stent struts, as well as the drug concentration at any location and time inside the arterial wall, together with several related quantities as the drug dose and the drug residence times.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号