共查询到20条相似文献,搜索用时 15 毫秒
1.
Liu A Liu F Xu Y Xu F Hu W Guo Q 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2008,867(1):144-148
A simple and sensitive HPLC/MS/MS method was developed and evaluated to determine the concentration of ritodrine (RTD) in human plasma. Liquid-liquid extraction with ethyl acetate was employed as the sample preparation method. The structural analogue salbutamol was selected as the internal standard (IS). The liquid chromatography was performed on a Hanbon Sci. & Tech. Lichrospher CN (150 mm x 4.6 mm, i.d., 5 microm) column (Hanbon, China) at 20 degrees C. A mixture of 0.03% acetic acid and methanol (50:50, v/v) was used as isocratic mobile phase to give the retention time 3.60 min for ritodrine and 2.94 min for salbutamol. Selected reaction monitoring (SRM) in positive ionization mode was employed for mass detection. The calibration functions were linear over the concentration range 0.39-100 ng mL(-1). The intra- and inter-day precision of the method were less than 15%. The lower limit of quantification was 0.39 ng mL(-1). The method had been found to be suitable for application to a pharmacokinetic study after oral administration of 20mg ritodrine hydrochloride tablet to 18 healthy female volunteers. The half-life is 2.54+/-0.67 h. 相似文献
2.
Felodipine quantification in human plasma by high-performance liquid chromatography coupled to tandem mass spectrometry 总被引:2,自引:0,他引:2
Migliorança LH Barrientos-Astigarraga RE Schug BS Blume HH Pereira AS De Nucci G 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2005,814(2):217-223
A rapid, sensitive, robust and specific method was developed for the determination and quantitation of felodipine, in human blood plasma by liquid chromatography coupled with tandem mass spectrometry using nimodipine as internal standard. Felodipine was extracted from 0.5 mL human plasma by use of a liquid/liquid procedure using diethyl ether/hexane (80/20, v/v) as eluent. The method included a chromatographic run of 5 min using a C(18) analytical column (100 mm x 4.6 mm i.d.) and the calibration curve was linear over the range from 0.02 to 10 ng mL(-1) (r(2) > 0.994). The between-run precision, determined as relative standard deviation of replicate quality controls, was 5.7% (0.06 ng mL(-1)), 7.1% (0.6 ng mL(-1)) and 6.8% (7.5 ng mL(-1)). The between-run accuracy was +/- 0.0, 2.1 and 3.1% for the above-mentioned concentrations, respectively. 相似文献
3.
Qiu P Chen X Chen X Lin L Ai C 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2008,875(2):471-477
A novel analytical method was developed and validated for the rapid and simultaneous analysis of five toxic alkaloids: Brucine, Strychnine, Ephedrine, Aconitine and Colchicine, in blood and urine using high-performance liquid chromatography-electrospray ionization tandem mass spectrometry in the multiple reaction monitoring (HPLC-ESI-MRM) mode. The linear range was 0.05-50.0 ng mL(-1) for Brucine, 0.1-50.0 ng mL(-1) for Strychnine and Ephedrine, 0.01-10.0 ng mL(-1) for Aconitine and Colchicine. The limits of quantification for Brucine, Strychnine, Ephedrine, Aconitine and Colchicine were found to be 0.03, 0.05, 0.20, 0.05, 0.01 ng mL(-1), respectively. The average extraction recoveries in urine ranged from 96.0 to 114.0% and in whole blood were 94.0 to 113.0%. The intra-day and inter-day RSDs were less than 8.3 and 10.6%, respectively. The five alkaloids could be well separated within 7 min in a single run. The established method should be suitable for the determination of trace alkaloids in body fluids. 相似文献
4.
Ekhart C Gebretensae A Rosing H Rodenhuis S Beijnen JH Huitema AD 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2007,854(1-2):345-349
Cyclophosphamide is a cytotoxic prodrug with a very narrow therapeutic index. To study the clinical pharmacology of cyclophosphamide in a large cohort of patients a previously published method for the simultaneous quantitative determination of cyclophosphamide and 4-hydroxycyclophosphamide in human plasma using liquid chromatography tandem mass spectrometry (LC-MS/MS) was optimized. Addition of an isotopically labelled internal standard and adaptation of the gradient resulted in a fast, robust and sensitive assay. Because 4-hydroxycyclophosphamide is not stable in plasma, the compound is derivatized with semicarbazide immediately after sample collection. Sample preparation was carried out by protein precipitation with methanol-acetonitrile (1:1, v/v), containing isotopically labelled cyclophosphamide and hexamethylphosphoramide as internal standards. The LC separation was performed on a Zorbax Extend C18 column (150 mm x 2.1 mm ID, particle size 5 microm) with 1 mM ammonium hydroxide in water-acetonitrile (90:10, v/v) as the starting gradient, at a flow-rate of 0.40 mL/min with a total run time of 6 min. The lower limit of quantification (LLQ, using a 100 microL sample volume) was 200 ng/mL and the linear dynamic range extended to 40,000 ng/mL for cyclophosphamide and 50-5000 ng/mL for 4-hydroxycyclophosphamide. Accuracies as well as precisions were lower than 20% at the LLQ concentration and lower than 15% for all other concentrations. This method has been successfully applied in our institute to support ongoing studies into the pharmacokinetics and pharmacogenetics of cyclophosphamide. 相似文献
5.
Zhao M Rudek MA He P Hartke C Gore S Carducci MA Baker SD 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2004,813(1-2):81-88
5-Azacytidine (5AC), a nucleoside analogue and hypomethylating agent, has anticancer properties and has been utilized in the treatment of various malignancies. 5AC is unstable and rapidly hydrolyzed to several by-products, including 5-azacytosine and 5-azauracil. A sensitive, reliable method was developed to quantitate 5AC using LC/MS/MS to perform pharmacokinetic and pharmacodynamic studies on 5AC combination therapy trials. Blood samples were collected in a heparinized tube and immediately processed for storage. To increase the stability of 5AC in plasma, 25 ng/mL tetrahydrouridine was added to the plasma and snap frozen. Plasma samples were extracted using acetonitrile then cleaned up by Oasis MCX ion exchange solid-phase extraction cartridges. 5AC was separated on an YMC Jsphr M80 C(18) column with gradient elution of ammonium acetate (2 mM) with 0.1% formic acid and methanol mobile phase. 5AC elutes at 5.0 +/- 0.2 min with a total run time of 30 min. Identification was through positive-ion mode and multiple reaction monitoring mode at m/z+ 244.9-->113.0 for 5AC and m/z+ 242.0-->126.0 for 5-methyl-2'-deoxycytidine, the internal standard. The lower limit of quantitation of 5AC was 5 ng/mL in human plasma, and linearity was observed from 5 to 500 ng/mL fitted by linear regression with 1/x weight. This method is 50 times more sensitive than previously published assays and successfully allows studies to characterize the pharmacokinetics and pharmacodynamics of 5AC. 相似文献
6.
Jin M Yang Y Su B Ren Q 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2007,846(1-2):169-175
A rapid, sensitive and selective high-performance liquid chromatography-tandem mass spectrometric method (HPLC-MS-MS) has been developed and validated for the determination of soyasaponins Ba and Bb in human serum using glycyrrhizin as internal standard (I.S.). Soyasaponins Ba and Bb were extracted from human serum by liquid-liquid extraction and cleaned up by C(18) solid-phase extraction (SPE), followed by separation on a C(18) reversed-phase column using acetonitrile/water containing 0.025% acetic acid as a mobile phase for gradient elution. Soyasaponins Ba and Bb, and I.S. were ionized by negative ion pneumatically assisted electrospray and detected by HPLC-MS-MS in the multiple-reaction monitoring (MRM) mode using precursor-->product ion combinations at m/z 958-->940, 942-->924 and 822-->351, respectively. The calibration curves were linear (r(2)>0.991) in the concentration range of 0.5-100.0 ng/mL, with lower limits of quantification of 0.5 and 0.3 ng/mL for soyasaponins Ba and Bb, respectively, in human serum. Intra-day and inter-day relative standard deviations (R.S.D.) were less than 7.9 and 11.3%, respectively. The mean recoveries of soyasaponins Ba and Bb ranged from 92 to 101% and from 85 to 94%, respectively. 相似文献
7.
Tang C 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2010,878(31):3317-3322
A sensitive, simple and feasible method has been developed and validated for the simultaneous determination of three diastereoisomers of hexabromocyclododecane (HBCD) in human plasma using liquid chromatography tandem mass spectrometry (LC-MS/MS). The simple pretreatment generally involved protein precipitation with methanol (MeOH). The separation was performed with a C18 reverse phase column. The mobile phases were 5mM ammonium acetate (NH(4)AC) in water and acetonitrile (ACN). The mass spectrometer was operated using negative electrospray ionization (ESI) source and the data acquisition was carried out with multiple reaction monitoring (MRM) mode. The analyte quantifications were performed by external standard method with matrix-matched calibration curves. The method was partially validated with the evaluations of accuracy, precision, linearity, limit of quantification (LOQ), limit of detection (LOD), recovery, matrix effect and carryover effect. With the present method, the intra-batch accuracies were 94.7-104.3%, 91.9-109.3% and 89.8-105.0% for α-, β- and γ-HBCD, respectively. And the inter-batch accuracies were ranged from 94.2% to 109.7%. Both intra-batch and inter-batch precisions (relative standard deviation, RSD, %) of the analytes were no more than 11.2%. The recoveries were from 79.0% to 108.9% and the LOQ was 10pg/mL for each diastereoisomer. The linear range was 10-10,000pg/mL with the linear correlation coefficient R(2)>0.996. No significant matrix effect and carryover effect of the analytes were observed in this study. This method is in possession of sufficient resolution, high sensitivity as well as selectivity and convenient to be applied to the trace determination of HBCDs in human plasma. 相似文献
8.
A. Ghulam M. Kouach A. Racadot A. Boersma M. C. Vantyghem G. Briand 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1999,727(1-2)
An original method based upon high-performance liquid chromatography coupled to electrospray ionization mass spectrometry has been developed for corticosterone (B) quantification in human serum. After extraction by diethyl ether using triamcinolone (T) as an internal standard, solutes are separated on a C18 microbore column (250×1.0 mm, I.D.), using acetonitrile–water–formic acid (40:59.9:0.1, v/v/v) as the mobile phase (flow-rate 40 μl/min). Detection is performed on an API 1 single quadrupole mass spectrometer equipped with a ESI interface and operated in positive ionization mode. Corticosterone quantifications were realized by computing peak area ratios (B/T) of the serum extracts analyzed in SIM mode (m/z 347 and m/z 395 for B and T, respectively), and comparing them with the calibration curve (r=0.998). 相似文献
9.
A validated method is described for the simultaneous analysis of PGE2, 11-, 12-, and 5-HETEs from cultured cells using HPLC negative electrospray ionization tandem mass spectrometry (LC/MS/MS). This method permits quantification of selected individual arachidonic acid metabolites from cell extracts without derivatization, multiple purification steps, or lengthy separation times required by traditional GC-MS- or HPLC-UV -based methods. Accuracy assessments of values calculated using this method showed deviations from nominal values were < or =15%. An average relative deviation of 7% of mean calculated values was observed for values taken on separate days. The lower limit of detection for all metabolites was 1.3 pg. The method was used to quantify arachidonic acid metabolites present in various cancer cell lines after incubation with arachidonic acid and the selective cyclooxygenase-2 inhibitor celecoxib. Results showed that the presence of celecoxib in lung cancer A549 cells reduced production of both PGE2 and 11-HETE in a concentration-dependent manner. 相似文献
10.
Xiaoyi Hu Marika Kamberi 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2009,877(20-21):1946-1950
The apolipoprotein A-I mimetic peptide D-4F is a potential therapeutical agent effective in maintaining cardiovascular health. A bioanalytical assay based on high-performance liquid chromatography coupled with electrospray ionization tandem mass spectrometry (LC/MS/MS) to quantitate the D-4F amount in rabbit plasma was developed and validated. A compound with a close structure similarity to the D-4F (only one amino acid A–V altered) was used as an internal standard. Both D-4F and the internal standard were extracted by protein precipitation using acetonitrile/0.2% Triton XL 80N. The correlation coefficient of the calibration curve was 0.9991 in the range 20–40,000 ng/mL. This assay can be used for pharmacokinetic studies of the drug. Also, it may be adjusted for the quantification of other members of apolipoprotein A-I mimetic peptide family. 相似文献
11.
Mostafa A Medley G Roberts DM Mohamed MS Elshanawani AA Roberts MS Liu X 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2011,879(23):2234-2238
Carbofuran (CFN), carbosulfan (CSN) and fenobucarb (FBC) are carbamate pesticides that are widely used in gardening and agriculture for the control of insects. Human poisoning due to occupational or self-poisoning exposures is also reported, so assays are required to quantify the plasma concentration of these insecticides. An LC-MS/MS method was developed and validated for the simultaneous quantification of these three carbamate insecticides in the plasma of patients with acute intentional self-poisoning. Plasma samples were pretreated by acetonitrile for protein precipitation. Chromatography was carried out on a Luna C18(2) analytical column with gradient elution using a mobile phase containing acetonitrile and water with 10mM ammonium acetate. Mass spectrometric analysis was performed by an Applied Biosystems MDS Sciex API 2000 triple quadrupole mass spectrometer coupled with electrospray ionization (ESI) source in the positive ion mode. The total run time was 7 min. The assay was validated over a concentration range from 10 to 1000 ng/ml for CSN and FBC and 20-2000 ng/ml for CFN. The precision and accuracy for both intra- and inter-day determination of all analytes were acceptable (<15%). No significant matrix effect was observed. Stability of compounds was established for short term bench and autosampler storage as well as freeze/thaw cycles. The method was effectively applied to 270 clinical samples from patients with a history of acute intentional carbamate self-poisoning. 相似文献
12.
Mendes GD Hamamoto D Ilha J Pereira Ados S De Nucci G 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2007,850(1-2):553-559
A rapid, sensitive and specific method for quantifying the aromatase inhibitor (anastrozole) in human plasma using dexchlorpheniramine as the internal standard (I.S.) is described herein. The analyte and the I.S. were extracted from 200 microl of human plasma by liquid-liquid extraction using a mixture of diethyl ether:dichloromethane (70:30, v/v) solution. Extracts were removed and dried in the organic phase then reconstituted with 200 microl of acetonitrile:water (50:50; v/v). The extracts were analyzed by high performance liquid chromatography coupled with photospray tandem mass spectrometry (HPLC-MS-MS). Chromatography was performed isocratically on a Genesis, C18 4 microm analytical column (100 mm x 2.1mm i.d.). The method had a chromatographic run time of 2.5 min and a linear calibration curve ranging from 0.05-10 ng ml(-1). The limit of quantification (LOQ) was 0.05 ng ml(-1). This HPLC-MS-MS procedure was used to assess pharmacokinetic studies. 相似文献
13.
Feng S Hu P Jiang J 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2011,879(11-12):763-768
Higenamine is an active ingredient of Aconite root in Chinese herbal medicine and might be used as a new agent for a pharmaceutical stress test and was approved to undergo clinical pharmacokinetic study. Therefore, there exists a need to establish a sensitive and rapid method for the determination of higenamine in human plasma and urine. This paper described a sensitive and rapid method based on liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) for the determination of higenamine in human plasma and urine. Solid-phase extraction (SPE) was used to isolate the compounds from biological matrices followed by injection of the extracts onto an Atlantis dC18 column with isocratic elution. The mobile phase was 0.05% formic acid in water-methanol (40:60, v/v). The mass spectrometry was carried out using positive electrospray ionization (ESI) and data acquisition was carried out in the multiple reaction monitoring (MRM) mode. The method was fully validated over the concentration range of 0.100-50.0 ng/mL and 1.00-500 ng/mL in plasma and urine, respectively. The lower limits of quantification (LLOQs) were 0.100 and 1.00 ng/mL in plasma and urine, respectively. Inter- and intra-batch precision was less than 15% and the accuracy was within 85-115% for both plasma and urine. Extraction recovery was 82.1% and 56.6% in plasma and urine, respectively. Selectivity, matrix effects and stability were also validated in human plasma and urine. The method was applied to the pharmacokinetic study of higenamine hydrochloride in Chinese healthy subjects. 相似文献
14.
Harazono A Kawasaki N Itoh S Hashii N Ishii-Watabe A Kawanishi T Hayakawa T 《Analytical biochemistry》2006,348(2):259-268
Ceruloplasmin has ferroxidase activity and plays an essential role in iron metabolism. In this study, a site-specific glycosylation analysis of human ceruloplasmin (CP) was carried out using reversed-phase high-performance liquid chromatography with electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS). A tryptic digest of carboxymethylated CP was subjected to LC-ESI-MS/MS. Product ion spectra acquired data-dependently were used for both distinction of the glycopeptides from the peptides using the carbohydrate B-ions, such as m/z 204 (HexNAc) and m/z 366 (HexHexNAc), and identification of the peptide moiety of the glycopeptide based on the presence of the b- and y-series ions derived from the peptide. Oligosaccharide composition was deduced from the molecular weight calculated from the observed mass of the glycopeptide and theoretical mass of the peptide. Of the seven potential N-glycosylation sites, four (Asn119, Asn339, Asn378, and Asn743) were occupied by a sialylated biantennary or triantennary oligosaccharide with fucose residues (0, 1, or 2). A small amount of sialylated tetraantennary oligosaccharide was detected. Exoglycosidase digestion suggested that fucose residues were linked to reducing end GlcNAc in biantennary oligosaccharides and to reducing end and/or alpha1-3 to outer arms GlcNAc in triantennary oligosaccharides and that roughly one of the antennas in triantennary oligosaccharides was alpha2-3 sialylated and occasionally alpha1-3 fucosylated at GlcNAc. 相似文献
15.
Wei G Xiao S Liu C 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2007,845(1):169-173
A rapid, sensitive and accurate liquid chromatographic-tandem mass spectrometric method is described for the determination of metolazone in human blood. Metolazone was extracted from blood using ethyl acetate and separated on a C18 column interfaced with a triple quadrupole tandem mass spectrometer. The mobile phase consisting of a mixture of acetonitrile, 10 mmol/l ammonium acetate and formic acid (60:40:0.1, v/v/v) was delivered at a flow rate of 0.5 ml/min. Electrospray ionization (ESI) source was operated in positive ion mode. Selected reaction monitoring (SRM) mode using the transitions of m/z 366-->m/z 259 and m/z 321-->m/z 275 were used to quantify metolazone and the lorazepam (internal standard), respectively. The linearity was obtained over the concentration range of 0.5-500 ng/ml for metolazone and the lower limit of quantitation (LLOQ) was 0.5 ng/ml. For each level of QC samples, inter- and intra-run precision was less than 8.07 and 3.56% (relative standard deviation (RSD)), respectively, and the bias was within +/-4.0%. This method was successfully applied to the pharmacokinetic study of metolazone formulation after oral administration to humans. 相似文献
16.
Kazuhiro Fujita Hiroshi Magara Hiroyuki Kobayashi 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1999,731(2):113
A rapid, sensitive and specific assay method has been developed to determine plasma concentrations of olopatadine hydrochloride (A) and its metabolites, M1 (B), M2 (C) and M3 (D), using high-performance liquid chromatography with electrospray ionization tandem mass spectrometry (LC–ESI-MS–MS). Olopatadine, its metabolites, and internal standard, KF11796 (E), were separated from plasma using solid-phase extraction (Bond Elut C18 cartridge). The eluate was dried, reconstituted and injected into the LC–ESI-MS–MS system. The calibration curves showed good linearity over the ranges 1–200 ng/ml for olopatadine and M3, and 2–100 ng/ml for M1 and M2, and the method was thoroughly validated and applied to the determination of olopatadine and its metabolites in plasma collected during Phase I clinical trials. Furthermore, the assay values were compared with those determined by the radioimmunoassay method, which has been routinely used to determine olopatadine in plasma. 相似文献
17.
Cai S Huo T Feng W Chen L Qin F Li F 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2008,868(1-2):83-87
A selective, rapid and sensitive ultra-performance liquid chromatography/tandem mass spectrometry (UPLC/MS/MS) method was developed for the quantitative determination of mitiglinide in human plasma. With nateglinide as internal standard, sample pretreatment involved a one-step extraction with diethyl ether of 0.2 mL plasma. The separation was performed on an ACQUITY UPLCtrade mark BEH C(18) column (50 mm x 2.1 mm, i.d., 1.7 microm) with the mobile phase consisting of methanol and 10 mmol/L ammonium acetate (65:35, v/v) at a flow rate of 0.25 mL/min. The detection was carried out by means of electrospray ionization mass spectrometry in positive ion mode with multiple reaction monitoring (MRM). Linear calibration curves were obtained in the concentration range of 1.080-5400 ng/mL, with a lower limit of quantification of 1.080 ng/mL. The intra- and inter-day precision (RSD) values were below 15% and accuracy (RE) was from -3.5% to 7.3% at all QC levels. The method was fully validated and successfully applied to a clinical pharmacokinetic study of mitiglinide in 10 healthy volunteers following oral administration. 相似文献
18.
He X Batchelor TT Grossman S Supko JG;New Approaches to Brain Tumor Therapy 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2004,799(2):281-291
Procarbazine is a cytotoxic chemotherapeutic agent used in the treatment of lymphomas and brain tumors. Its pharmacokinetic behavior remains poorly understood even though more than 30 years have elapsed since the drug was approved for clinical use. To characterize the pharmacokinetics of procarbazine in brain cancer patients during a phase I trial, a method for determining the drug in human plasma by reversed-phase high-performance liquid chromatography (HPLC) with electrospray ionization mass spectrometry (ESI-MS) was developed and thoroughly validated. Plasma samples were prepared for analysis by precipitating proteins with trichloroacetic acid and washing the protein-free supernatant with methyl tert-butyl ether to remove excess acid. The solution was separated on a Luna C-18 analytical column using methanol-25 mM ammonium acetate buffer, pH 5.1 (22:78, v/v) as the mobile phase at 1.0 ml/min. A single-quadrupole mass spectrometer with an electrospray interface was operated in the selected-ion monitoring mode to detect the [M+H](+) ions at m/z 222.2 for procarbazine and at m/z 192.1 for the internal standard (3-dimethylamino-2-methylpropiophenone). Procarbazine and the internal standard eluted as sharp, symmetrical peaks with retention times (mean+/-S.D.) of 6.3+/-0.1 and 9.9+/-0.3 min, respectively. Calibration curves of procarbazine hydrochloride in human plasma at concentrations ranging from 0.5 to 50 ng/ml exhibited excellent linearity. The mean absolute recovery of the drug from plasma was 102.9+/-1.0%. Using a sample volume of 150 microl, procarbazine was determined at the 0.5 ng/ml (1.9 nM) lower limit of quantitation with a mean accuracy of 105.2% and an interday precision of 3.60% R.S.D. on 11 different days over 5 weeks. During this same time interval, the between-day accuracy for determining quality control solutions of the drug in plasma at concentrations of 2.0, 15 and 40 ng/ml ranged from 97.5 to 98.2% (mean+/-S.D., 97.9+/-0.4%) and the precision was 3.8-6.2% (mean+/-S.D., 5.1+/-1.2%). Stability characteristics of the drug were thoroughly evaluated to establish appropriate conditions to process, store and prepare clinical specimens for chromatographic analysis without inducing significant chemical degradation. The sensitivity achieved with this assay permitted the plasma concentration-time profile of the parent drug to be accurately defined following oral administration of standard doses to brain cancer patients. 相似文献
19.
do Carmo Borges NC Mendes GD de Oliveira Silva D Marcondes Rezende V Barrientos-Astigarraga RE De Nucci G 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2005,822(1-2):253-262
A rapid, sensitive and specific method to quantify carvedilol in human plasma using metoprolol as the internal standard (IS) is described. The analyte and the IS were extracted from plasma by liquid-liquid extraction using a diethyl-ether solvent. After removed and dried the organic phase, the extracts were reconstituted with a fixed volume of acetonitrile-water (50/50; v/v). The extracts were analyzed by a high performance liquid chromatography coupled to electrospray tandem mass spectrometry (HPLC-MS/MS). Chromatography was performed isocratically on Alltech Prevail C18 5 microm analytical column, (150 mm x 4.6 mm i.d.). The method had a chromatographic run time of 3.5 min and a linear calibration curve over the range 0.1-200 ng ml(-1) (r2>0.997992). The limit of quantification was 0.1 ng ml(-1). This HPLC-MS/MS procedure was used to assess the bioequivalence of two carvedilol 25 mg tablet formulations (carvedilol test formulation from Laboratórios Biosintética Ltda and Coreg from Roche Químicos e Farmacêuticos S.A standard reference formulation). A single 25 mg dose of each formulation was administered to healthy volunteers. The study was conducted using an open, randomized, two-period crossover design with a 2-week wash-out interval. Since the 90% CI for C(max) and AUCs ratios were all inside the 80-125% interval proposed by the US Food and Drug Administration Agency, it was concluded that carvedilol formulation elaborated by Laboratórios Biosintética Ltda is bioequivalent to Coreg formulation for both the rate and the extent of absorption. 相似文献
20.
Yamada K Miyazaki T Shibata T Hara N Tsuchiya M 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2008,867(1):57-61
We have expanded a liquid chromatographic-tandem mass spectrometric method that measures 3-hydroxykynurenine and 3-hydroxyanthranilic acid in addition to tryptophan and kynurenine both intra- and extracellularly. After reversed phase HPLC separation, the compounds were detected in the MS positive multiple reaction monitoring mode. We found a good linear response for each tryptophan metabolite. The lower limit of quantification for each compound ranged from 0.01 to 0.1 microM. The extraction efficiencies from spiked cell samples and culture medium ranged between 83 and 111% and the overall coefficient of variation of analyses was less than 7%. Using our method, we found tryptophan metabolites in the cells and the culture medium of LN229 human glioma cells were stimulated by interferon-gamma, a known inducer of indoleamine 2,3-dioxygenase. The intracellular concentrations of kynurenine, 3-hydroxykynurenine and 3-hydroxyanthranilic acid were higher than those in the medium. This is the first report of a method for the simultaneous determination of tryptophan and its metabolic products both intra- and extracellularly. 相似文献