首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The electrochemistry of the redox proteins, cytochrome c, cytochrome b5, plastocyanin and ferredoxin at modified gold electrodes has been examined on the basis that electron transfer takes place at electroactive sites which are microscopic in size. Using this model, it is now proposed that electrochemistry of these proteins occurs at suitably modified sites with fast rates at potentials near the standard redox potential. The microscopic model implies that redox proteins and enzymes take part in fast electron transfer at specific sites on the electrode, other sites being completely ineffective. This form of molecular recognition, i.e. the ability to discriminate between the different sites on an electrode surface, mimics homogeneous redox reactions wherein redox active proteins 'recognize' their biological partners in a very specific sense. Previously, protein electrochemistry has been interpreted via use of a macroscopic model in which the proteins are transported to the electrode surface by linear diffusion followed by quasi-reversible or irreversible electron transfer to the electrode surface. The microscopic model, which assumes that the movement of the protein occurs predominantly by radial diffusion to very small sites, would appear to explain the data more satisfactorily and be consistent with biologically important, homogeneous redox reactions which are known to be fast.  相似文献   

2.
Redox hydrogels constitute the only electron-conducting phase in which water-soluble chemicals and biochemicals dissolve and diffuse. The combination of solubility and diffusion makes the electron-conducting gels permeable to water-soluble biochemicals and chemicals. The electron-conducting redox hydrogels serve to electrically connect the redox centers of enzymes to electrodes, enabling their use whenever leaching of electron-shuttling diffusional redox mediators must be avoided, which is the case in subcutaneously implanted biosensors for diabetes management and in miniature, potentially implantable, glucose-O2 biofuel cells. Because the hydrogels envelope the redox enzymes, they electrically wire the reaction centers to electrodes irrespective of spatial orientation and connect to electrode redox centers of multiple enzyme layers. Hence, the attained current densities of enzyme substrate electrooxidation or electroreduction are much higher than with enzyme monolayers packed onto electrode surfaces.  相似文献   

3.
We have studied the glucose oxidase immobilized carbon paste electrodes in the presence and absence of small mediator molecules. We have used p-benzoquinone and riboflavin as mediators in our studies. The effect of mediator molecules on the electron transfer between the enzyme redox centre and the electrode surface was explained from the cyclic voltammograms and rotating disk electrode data. In the absence of oxygen, we have noted that the mediators play a central role in the electron transfer. We have also proposed a possible mechanism for the electron transfer from enzyme active site to the electrode surface via mediators, based on our observations. Dedicated to the memory of Professor J Das  相似文献   

4.
This study demonstrated that redox hydrogel-modified carbon nanotube (CNT) electrodes can be developed as an amperometric sensor that are sensitive, specific and fast and do not require auxiliary enzymes. A redox polymer, poly(vinylimidazole) complexed with Os(4,4'-dimethylbpy)(2)Cl (PVI-dmeOs) was electrodeposited on Ta-supported multi-walled CNTs. The resulted PVI-dmeOs thin film did not change the surface morphology of the CNTs, but turned the CNT surface from hydrophobic to hydrophilic, as studied by scanning electron microscopy (SEM) and static water contact angle measurements. Cyclic voltammetry measurements in a Fe(CN)(6)(3-) solution and electrochemical impedance measurements in an equimolar Fe(CN)(6)(3-/4-) solution demonstrated that the PVI-dmeOs hydrogel thin film was electronic conductive with a resistance of about 15Omega. The PVI-dmeOs/CNT electrodes sensed rapidly, sensitively and specifically to model redox enzymes (glucose oxidase (GOD) and lactate oxidase (LOD)) in amperometric experiments in electrolyte solutions containing the substrates of the measured redox enzymes. Both the CNT substrate and the thin PVI-dmeOs film enhanced the sensing sensitivities. Exploration of the mechanisms suggests that the PVI-dmeOs film may enhance the sensing sensitivities by wiring the enzyme molecules through the redox centers tethered on the mobile redox polymer backbones to the CNT electrodes.  相似文献   

5.
Several anaerobic metal-reducing bacteria have been shown to be able to donate electrons directly to an electrode. This property is of great interest for microbial fuel cell development. To date, microbial fuel cell design requires avoiding O(2) diffusion from the cathodic compartment to the sensitive anodic compartment. Here, we show that Acidiphilium sp. strain 3.2 Sup 5 cells that were isolated from an extreme acidic environment are able to colonize graphite felt electrodes. These bacterial electrodes were able to produce high-density electrocatalytic currents, up to 3 A/m(2) at a poised potential of +0.15 V (compared to the value for the reference standard calomel electrode) in the absence of redox mediators, by oxidizing glucose even at saturating air concentrations and very low pHs.  相似文献   

6.
Stable films of didodecyldimethylammonium bromide (DDAB, a synthetic lipid) and horseradish peroxidase (HRP) were made by casting the mixture of the aqueous vesicle of DDAB and HRP onto the glassy carbon (GC) electrode. The direct electron transfer between electrode and HRP immobilized in lipid film has been demonstrated. The lipid films were used to supply a biological environment resembling biomembrane on the surface of the electrode. A pair of redox peaks attributed to the direct redox reaction of HRP were observed in the phosphate buffer solution (pH 5.5). The cathodic peak current increased dramatically while anodic peak decreased by addition of small amount H(2)O(2). The pH effect on amperometric response to H(2)O(2) was studied. The biosensor also exhibited fast response (5 s), good stability and reproducibility.  相似文献   

7.
Cyclic voltammetry was used for simultaneous formation and immobilization of nickel oxide nano-scale islands and catalase on glassy carbon electrode. Electrodeposited nickel oxide may be a promising material for enzyme immobilization owing to its high biocompatibility and large surface. The catalase films assembled on nickel oxide exhibited a pair of well defined, stable and nearly reversible CV peaks at about -0.05 V vs. SCE at pH 7, characteristic of the heme Fe (III)/Fe (II) redox couple. The formal potential of catalase in nickel oxide film were linearly varied in the range 1-12 with slope of 58.426 mV/pH, indicating that the electron transfer is accompanied by single proton transportation. The electron transfer between catalase and electrode surface, (k(s)) of 3.7(+/-0.1) s(-1) was greatly facilitated in the microenvironment of nickel oxide film. The electrocatalytic reduction of hydrogen peroxide at glassy carbon electrode modified with nickel oxide nano-scale islands and catalase enzyme has been studied. The embedded catalase in NiO nanoparticles showed excellent electrocatalytic activity toward hydrogen peroxide reduction. Also the modified rotating disk electrode shows good analytical performance for amperometric determination of hydrogen peroxide. The resultant catalase/nickel oxide modified glassy carbon electrodes exhibited fast amperometric response (within 2 s) to hydrogen peroxide reduction (with a linear range from 1 microM to 1 mM), excellent stability, long term life and good reproducibility. The apparent Michaelis-Menten constant is calculated to be 0.96(+/-0.05)mM, which shows a large catalytic activity of catalase in the nickel oxide film toward hydrogen peroxide. The excellent electrochemical reversibility of redox couple, high stability, technical simplicity, lake of need for mediators and short preparations times are advantages of this electrode. Finally the activity of biosensor for nitrite reduction was also investigated.  相似文献   

8.
Direct and indirect electron transfer between electrodes and redox proteins   总被引:4,自引:0,他引:4  
The direct electrochemistry of redox proteins has been achieved at a variety of electrodes, including modified gold, pyrolytic graphite and metal oxides. Careful design of electrode surfaces and electrolyte conditions are required for the attainment of rapid and reversible protein-electrode interaction. The electron transfer reactions of more complex systems, such as redox enzymes, are now being examined. The 'well-behaved' electrochemistry of redox proteins can be usefully exploited by coupling the electrode reaction to enzymes for which the redox proteins act as cofactors. In systems where direct electron transfer is very slow, small electron carriers, or mediators, may be employed to enhance the rate of electron exchange with the electrode. The organometallic compound ferrocene and its derivatives have proved particularly effective in this role. A new generation of electrochemical biosensors employs ferrocene derivatives as mediators.  相似文献   

9.
Indirectly heated electrodes operating in a non-isothermal mode have been used as transducers for reagentless glucose biosensors. Pyrroloquinoline quinone-dependent soluble glucose dehydrogenase (PQQ-sGDH) was entrapped on the electrode surface within a redox hydrogel layer. Localized polymer film precipitation was invoked by electrochemically modulating the pH-value in the diffusion zone in front of the electrode. The resulting decrease in solubility of an anodic electrodeposition paint (EDP) functionalized with Osmium complexes leads to precipitation of the redox hydrogel concomitantly entrapping the enzyme. The resulting sensor architecture enables a fast electron transfer between enzyme and electrode surface. The glucose sensor was operated at pre-defined temperatures using a multiple current-pulse mode allowing reproducible indirect heating of the sensor. The sensor characteristics such as the apparent Michaelis constants K(M)(app) and maximum currents I(max)(app) were determined at different temperatures for the main substrate glucose as well as a potential interfering co-substrate maltose. The limit of detection increased with higher temperatures for both substrates (0.020 mM for glucose, and 0.023 mM for maltose at 48 degrees C). The substrate specificity of PQQ-sGDH is highly temperature dependent. Therefore, a mathematical model based on a multiple linear regression approach could be applied to discriminate between the current response for glucose and maltose. This allowed accurate determination of glucose in a concentration range of 0-0.1mM in the presence of unknown maltose concentrations ranging from 0 to 0.04 mM.  相似文献   

10.
The phase and electrochemical behavior of the aqueous mixtures of monoolein (MO) and synthetic ferrocene (Fc) derivatives containing long alkyl chains-(Z)-octadec-9-enoylferrocene (1), (Z)-octadecen-9-ylferrocene (2), and ferrocenylmethyl (Z)-octadec-9-enoate (3)-were studied. At low hydration, the reversed micelles (L(2) phase) and cubic Q(230) phase of MO can accommodate relatively high amounts (>6 wt.%) of the Fc-derivative 2, whereas at high hydration, the pseudoternary cubic phase Q(224) is destabilized even at about 2 wt.% of this Fc. Increasing the Fc-derivative content induces L(alpha)-->L(2) and L(alpha)-->reversed bicontinuous cubic phase (Q(II))-->H(II) transitions depending upon hydration. A rough study of the MO system containing compounds 1 and 3 indicates very similar phase behavior to that of the MO/2/H(2)O system. Compound 2 apparently has no effect on the lipid monolayer thickness in the pseudoternary L(alpha), H(II) and Q(II) liquid crystalline phases of MO. Within a 3D-structure of the Q(224) phase, derivatives 1-3 exhibit electrochemical activity on the gold electrode. The one-electron redox conversion processes are electrochemically quasi-reversible and controlled by diffusion. The values of apparent diffusion coefficient (D(app)) and heterogeneous electron-transfer rate constant (k(s)) of Fcs are significantly lower in the cubic phase matrix when compared to the acetonitrile solution. By contrast, the MO H(II) phase with entrapped Fc-derivatives does not exhibit electrochemical activity on the electrode surface. It is suggested that the diffusional anisotropy and/or localized aggregation of compounds 1-3 within a 2D-structure of the H(II) phase account(s) for the latter observation.  相似文献   

11.
Di J  Bi S  Zhang M 《Biosensors & bioelectronics》2004,19(11):1479-1486
A third-generation biosensor for superoxide anion (O(2)*-) was developed based on superoxide dismutase (SOD) immobilized by thin silica-PVA sol-gel film on gold electrode surface. A rapid and direct electron transfer of SOD in the thin sol-gel film at the gold electrode was realized without any mediators or promoters. The characterization of the SOD electrodes showed a quasi-reversible electrochemical redox behavior with a formal potential of 80 + 5 mV (versus SCE) in 50 mmol l(-1) phosphate buffer solution (PBS), pH 7.0. The heterogeneous electron transfer rate constant was evaluated to be about 2.1s(-1). The anodic and cathodic transfer coefficients are 0.6 and 0.4, respectively. Based on biomolecular recognition for specific reactivity of SOD toward O(2)*- the SOD electrode was applied to a sensitive and selective measurement of O(2)*- with the low operation potential (-0.15 V versus SCE) in phosphate buffer solution, pH 7.0. The amperometric response was proportional to O(2)*- concentration in the range of 0.2-1.6 micromol l(-1) and the detection limit was 0.1 micromol l(-1) at a signal-to-noise ration of 3. The preparation of SOD electrode is easy and simple. The uniform porous structure of the silica-PVA sol-gel matrix results in a fast response rate of immobilized SOD and is very efficient for stabilizing the enzyme activity.  相似文献   

12.
A novel biosensor architecture, which is based on the combination of a manual and a non-manual deposition technique for sensor components on the electrode surface is reported. A water-soluble Os-poly(vinyl-imidazole) redox hydrogel is deposited on a graphite electrode by drop-coating (i.e. manually) followed by the electrochemically-induced deposition of an enzyme-containing non-conducting polymer film. The local polymer deposition is initiated by electrochemical generation of H(3)O(+) exclusively at the electrode surface causing a pH-shift to be established in the diffusion zone around the electrode (i.e. non-manually). This pH-shift leads to the protonation of a dissolved polyanionic polymer which in consequence changes significantly its solubility and is hence precipitating on the electrode surface. In the presence of a suitable enzyme, such as quinohemoprotein alcohol dehydrogenase (QH-ADH), the polymer precipitation leads to an entrapment of the redox enzyme within the polymer film. Simultaneously, the water-soluble Os-poly(vinyl-imidazole) redox hydrogel, which is slowly dissolving from the electrode surface after addition of the electrolyte, is co-entrapped within the precipitating polymer layer. This provides the pre-requisite for an efficient electron-transfer pathway from the redox enzyme via the polymer-bound redox centres to the electrode surface. The sensor preparation protocol has been optimised aiming on a high mediator concentration in the polymer film and an effective electron transfer.  相似文献   

13.
Development of reagentless biosensors implies the tight and functional immobilisation of biological recognition elements on transducer surfaces. Specifically, in the case of amperometric enzyme electrodes, electron-transfer pathways between the immobilised redox protein and the electrode surface have to be established allowing a fast electron transfer concomitantly avoiding free-diffusing redox species. Based on the specific nature of different redox proteins and non-manual immobilisation procedures possible biosensor designs are discussed, namely biosensors based on (i) direct electron transfer between redox proteins and electrodes modified with self-assembled monolayers; (ii) anisotropic orientation of redox proteins at monolayer-modified electrodes; (iii) electron-transfer cascades via redox hydrogels; and (iv) electron-transfer via conducting polymers.  相似文献   

14.
A sensitive conductimetric immunosensor has been demonstrated based on an ultrathin platinum film on an oxidized silicon base. The film is about 25 A thick and is seen to consist of a discontinuous layer with channels 20-30 A wide. Monoclonal antibodies were bound to the sensor surface using conventional biosensor chemistry. Impedance at fixed frequencies across the film was used to track modification and binding at the surface. Impedance increased 55% at 20 Hz during the activation of the surface with anti-alkaline phosphatase (anti-AP). Binding of alkaline phosphatase (AP) to the prepared surface results in a further increase of 12%. p-Nitrophenyl phosphate hydrolysis confirmed binding and activity of the AP. About 40 amol AP were bound on the 0.5 cm(2) electrode. Non-specific binding of horseradish peroxidase caused an impedance change <6%. Control experiments showed small impedance changes and trace enzyme activity. Since the mechanism of electrical conduction of the thin film was not established, modeling of thin-film response was used to distinguish between redox processes, capacitance and tunneling mechanisms. The data fit well with the diffusion distributed elements (DE) model as well as a transmission line distribution element (DX) model. The first model, DE, is distributed elements for diffusion. The second DX model represents a transmission line. The sensors behave in a distributed network or like a transmission line.  相似文献   

15.
An integrated microfluidic device with injecting, flushing, and sensing functions was realized using valves that operate based on direct electrowetting. The device consisted of two substrates: a glass substrate with driving and sensing electrodes and a poly(dimethylsiloxane) (PDMS) substrate. Microfluidic transport was achieved using the spontaneous movement of solutions in hydrophilic flow channels formed with a dry-film photoresist layer. The injection and flushing of solutions were controlled by gold working electrodes, which functioned as valves. The valves were formed either in the channels or in a through-hole in the glass substrate. To demonstrate the system's applicability to an immunoassay, the detection of immobilized antigens was performed as a partial simulation of a sandwich immunoassay. Human -fetoprotein (AFP) or an anti-human AFP antibody was immobilized on a platinum working electrode in the chamber using a plasma-polymerized film (PPF). By applying a potential to the injection valves, necessary solutions were injected one by one through the channels into a reaction chamber at the center of the chip and incubated for reasonable periods of time. The solutions were then flushed through the flushing valve and absorbed in a filter paper placed under the device. After incubation with the corresponding antibodies labeled with glucose oxidase (GOD), electrochemical detection was conducted. In both cases, the obtained current depended on the amount of immobilized antigen. The calibration curves were sigmoidal, and the detection limit was 0.1 ng. The developed microfluidic system could potentially be a fundamental component for a micro immunoassay of the next generation.  相似文献   

16.
The present study aims at investigating the use of redox dyes as non-diffusional electron mediators in hydrogen peroxide biosensors using horseradish peroxidase (HRP). We observe that the two redox dyes Safranine O and Neutral Red covalently bound to HRP, efficiently mediate electron transfer from the active site of the enzyme to the electrode surface. Dyes bound to the enzyme using a spacer arm diaminohexane further enhance the electron transfer. The enzyme electrodes show a linear response to the concentration of H2O2 up to 500 microM concentration and with a detection limit of around 50 microM. The dyes can be used as coupled mediators to develop a successful electro-optical biosensor.  相似文献   

17.
The demonstration of a labeless immunosensor for the detection of pathogenic bacteria using screen printed gold electrodes (SPGEs) and a potassium hexacyanoferrate(II) redox probe is reported. Gold electrodes were produced using screen printing and the gold surfaces were modified by a thiol based self assembled monolayer (SAM) to facilitate antibody immobilisation. SAMs based on the use of thioctic acid (TA), mercaptopropionic acid (MPA) and mercaptoundecanoic acid (MUA) were evaluated. Following antibody immobilisation via the optimum SAM, the redox behaviour and diffusion co-efficient (D) of the potassium hexacyanoferrate(II) probe was monitored in the absence and presence of analyte. In the presence of analyte, a change in the apparent diffusion co-efficient of the redox probe was observed, attributable to impedance of the diffusion of redox electrons to the electrode surface due to the formation of the antibody-bacteria immunocomplex. No change in the diffusion co-efficient was observed when a non-specific antibody (mouse IgG) was immobilised and antigen added. The system has been demonstrated with Listeria monocytogenes and Bacillus cereus.  相似文献   

18.
Bicontinuous lipidic cubic phases can be used as a host for growing crystals of membrane proteins. Since the cubic phase is stiff, handling is difficult and time-consuming. Moreover, the conventional cubic phase may interfere with the hydrophilic domains of membrane proteins due to the limited size of the aqueous pores. Here, we introduce a new crystallization method that makes use of a liquid analogue of the cubic phase, the sponge phase. This phase facilitates a considerable increase in the allowed size of aqueous domains of membrane proteins, and is easily generalised to a conventional vapour diffusion crystallisation experiment, including the use of nanoliter drop crystallization robots. The appearance of the sponge phase was confirmed by visual inspection, small-angle X-ray scattering and NMR spectroscopy. Crystals of the reaction centre from Rhodobacter sphaeroides were obtained by a conventional hanging-drop experiment, were harvested directly without the addition of lipase or cryoprotectant, and the structure was refined to 2.2 Angstroms resolution. In contrast to our earlier lipidic cubic phase reaction centre structure, the mobile ubiquinone could be built and refined. The practical advantages of the sponge phase make it a potent tool for crystallization of membrane proteins.  相似文献   

19.
A novel amperometric biosensor highly selective to L-lactate has been developed using L-lactate-cytochrome c oxidoreductase (flavocytochrome b2) isolated for the first time from thermotolerant methylotrophic yeast Hansenula polymorpha as biorecognition element. Different immobilization methods and low-molecular free-diffusing redox mediators have been tested for optimising the electrochemical communication between the immobilized enzyme and the electrode surface. Moreover, the possibility of direct electron transfer from the reduced form of FCb2 to carbon electrodes has been evaluated. The bioanalytical properties of FCb2-based biosensors, such as signal rise time, dynamic range, dependence of the sensor output on the pH value, the temperature and the storage stability were investigated, and the proposed biosensor demonstrated a very fast response and a high sensitivity and selectivity for L-lactate determination.  相似文献   

20.
Amperometry is a powerful voltammetric measuring method. Its application is specially advantageous when used in combination with a separation step or with some other sample treatment method providing selectivity. The selectivity is often achieved by coating the amperometric working electrode surface with a membrane of special character. Size exclusion membrane, immobilized enzyme containing reaction layer, protecting dialysis membrane, perm selective ion exchange film etc can be mentioned here. In conventional amperometry the measuring potential is continuously applied, therefore in case of membrane coated electrodes the electrode process depletes the diffusion layer. In this work the performance of a new periodically interrupted amperometric (PIA) measuring program has been investigated in case of glucose enzyme sensor. The measuring program allowing time for reloading the diffusion layer provided higher current and therefore improved sensitivity and lower limit of detection.  相似文献   