1.
A sensitive gas chromatographic method with flame ionization detection was developed for the analysis in plasma of the novel anticonvulsant d,l-3-hydroxy-3-ethyl-3-phenylpropionamide (HEPP), using d,l-2-hydroxy-2-ethyl-2-phenylacetamide as the internal standard. HEPP was extracted from alkalinized plasma into dichloromethane and quantified after derivatization with bis(trimethylsilyl)-trifluoroacetamide. Standard curves were linear from 0.5 to 50 and from 2 to 100 μg/ml of plasma, using 1.5 and 5 μg of the internal standard, respectively. The lower limit of detection at a signal-to-noise ratio of 3 standard deviations was 0.33 μg/ml of sample. The sensitivity, accuracy and reproducibility of the method were shown to be satisfactory for pharmacokinetic studies of HEPP. After intraperitoneal administration of 50 mg/kg to Wistar rats, the principal kinetic parameters were: absorption half-life = 0.04 h; volume of distribution = 1.32 l/kg; clearance = 4.40 ml/min; peak concentration = 50 μg/ml; peak time = 0.25 h; mean residence time = 4.55 h.  相似文献   

2.
A gas chromatographic technique for determining zopiclone based on a solid-phase extraction procedure with C18 cartridge for sample clean-up is presented. Quantification can be achieved with 1 ml of plasma. The method uses prazepam as internal standard. Zopiclone is separated on a 5% phenyl methyl silicone analytical column and detected with an electron-capture detector, which consequently allows a limit of quantitation of 2 μg/l. It is thus simple, rapid, sensitive and linear over the range 5–2000 μg/l.  相似文献   

3.
Total fatty acids in plasma of neonates have been analysed as their methyl esters by gas chromatography. They were separated on a capillary column coated with a SP-2380 stationary phase. As little as 100 μl of plasma is used for the analysis. The extraction procedure was performed with dichloromethane—methanol (2:1) and fatty acids were methylated with boron trifluoride—methanol. The quantification of fatty acids is based on an internal standard method. Absolute values (μg fatty acid per 100 μl plasma) are given together with relative values (%). At a signal-to-noise ratio of 3, the detection limits for flame ionisation detection are between 0.08 to 0.51 ng. The high sensitivity and precision permits the effective determination of the fatty acids in neonate plasma.  相似文献   

4.
A method has been developed for the separation and measurement of ethylene glycol and three other glycols (propylene glycol, 1,3-butylene glycol and 2,3-butylene glycol) in biological samples by wide-bore column gas chromatography with a flame ionization detector. The method used 1,3-propylene glycol (1,3-propanediol) as an internal standard. The method was linear at least from 2 to 1000 μg/ml, with a detection limit of 1 μg/ml. Analytical recoveries were 89–98% for the different concentrations. Precision studies showed coefficients of variation of 1.5–7.7% for the different concentrations. The assay was applied to the analysis of biological samples from two patients who had ingested ethylene glycol and/or other glycols in a suicide attempt.  相似文献   

5.
A method is described for the quantitative analysis of 6,11-dihydro-11-oxo-dibenz[b,e] - oxepin-2-acetic acid (isoxepac) in plasma and urine. Isoxepac and internal standard are extracted from acidified plasma and urine, converted to the corresponding methyl esters and analysed by gas—liquid chromatography using a flame ionization detector. The method is accurate and precise over the range 0.1–30 μg/ml. The method has been applied to the analysis of plasma and urine from both healthy volunteers and patients receiving therapeutic oral doses of isoxepac.  相似文献   

6.
A sensitive gas—liquid chromatographic technique for the quantitative analysis of SCH-12679 (d-7,8-dimethoxy-3-methyl-phenyl-2,3,4,5-tetrahydro-1H-3-benzazepine acid maleate) and its major metabolites in plasma of aggressive mental retardates receiving therapeutic doses of the medicament has been developed. The lower limits of detection are 20 ng/ml for SCH-12679, 0.5 ng/ml for 3-desmethyl SCH-12679 and 0.4 ng/ml for 7-desmethyl plus 8-desmethyl SCH-12679. SCH-12679 is estimated with a flame ionization detector. Its metabolites are quantitated using an electron-capture detector after conversion of the compounds to their heptafluorobutyryl derivatives by reaction with the appropriate anhydride. Data on plasma levels of unchanged SCH-12679, 3-desmethyl SCH-12679 and a combination of 7-desmethyl and 8-desmethyl SCH-12679 in fifteen patients treated with the medicament are presented.  相似文献   

7.
A method for the routine clinical examination of serum gliclazide by high-performance liquid chromatography (HPLC) on a column packed with a macroporous anion-exchange resin, Diaion CDR-10, was developed. The elution was performed with acetonitrile—methyl alcohol—1.2 M ammonium perchlorate (4:3:7, v/v/v) at a flow-rate of 0.4 ml/min. The retention time of gliclazide was 15 min. It seems that the retention mechanism of gliclazide under the HPLC conditions described is not only ion-exchange mode but reversed-phase mode between the anion-exchange resin and the mobile phase. The detection limit of gliclazide was 0.2 μg/ml in plasma. The coefficient of variation for the within-day assay was 5.0% (0.2 μg/ml, n=8). The decay curve of serum gliclazide in diabetic patients was determined.  相似文献   

8.
An automated gas chromatographic—mass spectrometric assay for theophylline is described. Theophylline is extracted from plasma or urine (50 μl) and transformed into an N-pentyl derivate. The internal standard used for quantitation is [1,3-15N, 2-13C]theophylline. The detection is performed by monitoring the molecular ions 250 for theophylline and 253 for the internal standard with a quadrupole mass specific detector HP 5790 A. The system has been fully automated: injection, calibration, assay, calculation. The method shows excellent analytical parameters: linearity between 2 and 40 μg/ml; day-to-day reproducibility 1.82% for a concentration of 15 μg/ml; repeatability 0.75% (15 μg/ml) and 0.33% (30 μg/ml). Accuracy is also excellent. Due to the use of an internal standard labelled with stable isotopes, the specificity and high analytical quality of the method make it useful as a reference method to compare with routine theophylline assays.  相似文献   

9.
A simple purge-and-trap gas chromatographic method with flame ionization detection was developed for the determination of styrene in urine and blood. Styrene present in a 5 ml sample at room temperature was swept by helium at 40 ml/min for 11 min, trapped on a Tenax trap, desorbed by heating, cryofocused, and injected by flash heating into a DB-5 capillary GC column. The oven temperature program was from 80°C, held for 8 min, to 120°C at 5°C/min, and then held for 2 min. The detector temperature was 250°C. The calibration curves were linear in the range of 2.5–15 ppb styrene in urine and 25–150 ppb in blood. The detection limits calculated were 0.4 μg/l in urine and 0.6 μg/l in blood. The coefficients of variations within the day and day-to-day were 3 and 3.1%, respectively, for 2.5 ppb of styrene in urine, and 1 and 1.6% for 25 ppb of styrene in blood. The results obtained from samples taken from workers exposed to styrene were reported.  相似文献   

10.
The lipid contents of human platelets from twenty-one healthy adults were analysed using thin-layer chromatography in combination with flame ionization detection.The weight per cent of neutral lipids in human platelets was 14.6%, which consisted mainly of free cholesterol, that of phosphatidylethanolamine 24.9%, phosphatidylserine plus phosphatidylinositol 6.8%, phosphatidylcholine 35.2% and sphingomyelin 18.6%. Free cholesterol in 108 platelets was estimated as 7 μg and phospholipids as 46 μg from calibration standards. The reproducibility was satisfactory and the procedure could be performed quickly and simply.  相似文献   

11.
A gas—liquid chromatographic procedure is presented for the determination of therapeutic and toxic serum levels of doxepin and loxapine, using a nitrogen—phosphorus-sensitive detector. Amitriptyline is used as the internal standard. The method is accurate, sensitive and specific with no derivatization required prior to analysis. An advantage of the procedure is the small serum sample size needed for analysis and the selectivity and sensitivity of the detector, with the limit of detection being 3 and 2 μg/l for doxepin and loxapine, respectively. Nine cases of doxepin and loxapine misuse are presented. Serum doxepin concentrations ranged from 113 to 439 μg/l, with a loxapine concentration of 192 μg/l observed in one patient. The presence of the tricyclics was identified and confirmed by gas chromatography—mass spectrometry and the mass spectrum of loxapine is reported.  相似文献   

12.
A sensitive and quantitative gas chromatographic assay for the determination of 18β-glycyrrhetinic acid (18β-GA), the main metabolite of glycyrrhizin after oral licorice consumption in human urine, has been developed and validated. For the extraction of 18β-GA from urine two Sep-Pak C18 extractions, hydrolysis with Helix pomatia and three liquid–liquid extractions were performed, using 18α-glycyrrhetinic acid (18α-GA) as internal standard. Both 18β-GA and internal standard were converted into their pentafluorobenzyl-ester/trimethylsilyl-ether derivatives and detected by flame ionization detection using a WCOT-fused-silica capillary column. Good quality control data were obtained in precision and accuracy tests. The detection limit of the gas chromatographic method was 10 μg/l with a urine volume of 10 ml. A detection limit of 3 μg/l was obtained by performing GC–MS. The GC method was used to monitor the urinary excretion of 18β-GA after licorice consumption by two healthy volunteers and a patient suspected of licorice abuse. Furthermore, it was shown that this GC assay enables to detect other metabolites related to licorice consumption.  相似文献   

13.
An ethanolic extract of cloves was analyzed by gas chromatography directly to identify eugenol and other major phenolic compounds without previous separation of other components. Separation was performed on a fused-silica capillary column of 30 mx0.53 mm I.D., 0.53 μm film thickness. The detector was a flame ionization detector. Helium gas at a flow-rate of 3 ml/min was used as a carrier gas. The analysis were performed with linear temperature programming. Nine components were detected and special attention was given to the major phenolic compound, eugenol.  相似文献   

14.
A gas chromatographic method with nitrogen–phosphorus detection involving a solid–liquid extraction phase was developed and validated for the simultaneous quantification of 3,4-methylenedioxymethamphetamine (MDMA) and 3,4-methylenedioxyamphetamine (MDA) in plasma. A modification of this method was validated for the analysis of MDMA, MDA, 4-hydroxy-3-methoxymethamphetamine (HMMA) and, 4-hydroxy-3-methoxyamphetamine (HMA) in urine. Under the analytical conditions described, the limits of detection in plasma and urine were less than 1.6 μg/l and 47 μg/l, respectively, for all the compounds studied. Good linearity was observed in the concentration range evaluated in plasma (5–400 μg/l) and urine (100–2000 μg/l) for all compounds tested. The recoveries obtained from plasma were 85.1% and 91.6% for MDMA and MDA, respectively. Urine recoveries were higher than 90% for MDMA and MDA, 74% for HMMA, and 64% for HMA. Methods have been successfully used in the assessment of plasma and urine concentrations of MDMA and its main metabolites in samples from clinical studies in healthy volunteers.  相似文献   

15.
A sensitive and accurate stable isotope dilution assay was developed for the measurement of pipecolic acid in body fluids using capillary gas chromatography with electron-capture detection. The method utilizes [2H11]pipecolic acid as the internal standard. Sample preparation consisted of derivatization in aqueous solution (pH 11.5) of the amine moiety with methyl chloroformate to the N-methylcarbamate, followed by acidic ethyl acetate extraction at pH ≤ 2 and further derivatization of the carboxyl moiety with pentafluorobenzyl bromide, the excess of which was removed by solid-phase extraction. Control values have been determined in the plasma of at-term infants, age > 1 week (n = 21, mean = 1.36 μM, range = 0.47–3.27 μM). The utility of the method was demonstrated by quantitating pipecolic acid in biological fluids derived from patients with peroxisomal disorders. The method was validated against an established electron-capture negative ion mass fragmentographic technique.  相似文献   

16.
Methods for the determination of 3,4-dichloroaniline (3,4-DCA) and 3,5-dichloroaniline (3,5-DCA) as common markers of eight non-persistent pesticides in human urine are presented. 3,5-DCA is a marker for the exposure to the fungicides vinclozolin, procymidone, iprodione, and chlozolinate. Furthermore the herbicides diuron, linuron, neburon, and propanil are covered using their common marker 3,4-DCA. The urine samples were treated by basic hydrolysis to degrade all pesticides, metabolites, and their conjugates containing the intact moieties completely to the corresponding dichloroanilines. After addition of the internal standard 4-chloro-2-methylaniline, simultaneous steam distillation extraction (SDE) followed by liquid–liquid extraction (LLE) was carried out to produce, concentrate and purify the dichloroaniline moieties. Gas chromatography (GC) with mass spectrometric (MS) and tandem mass spectrometric (MS–MS) detection and also detection with an electron-capture detector (ECD) after derivatisation with heptafluorobutyric anhydride (HFBA) were employed for separation, detection, and identification. Limit of detection of the GC–MS–MS and the GC–ECD methods was 0.03 and 0.05 μg/l, respectively. Absolute recoveries obtained from a urine sample spiked with the internal standard, 3,5-, and 3,4-DCA, ranged from 93 to 103% with 9–18% coefficient of variation. The three detection techniques were compared concerning their performance, expenditure and suitability for their application in human biomonitoring studies. The described procedure has been successfully applied for the determination of 3,4- and 3,5-DCA in the urine of non-occupationally exposed volunteers. The 3,4-DCA levels in these urine samples ranged between 0.13 and 0.34 μg/g creatinine or 0.11 and 0.56 μg/l, while those for 3,5-DCA were between 0.39 and 3.33 μg/g creatinine or 0.17 and 1.17 μg/l.  相似文献   

17.
We developed and characterized a high-performance liquid chromatographic assay for the determination of nelfinavir (NFV), a potent HIV protease inhibitor, and its active metabolite M8 in human plasma. Extraction of the internal standard, M8 and NFV from the plasma buffered at pH 9.5 was achieved by a liquid–liquid extraction with a mixture of methyl-tert.-butyl ether and hexane. Following two washes of the reconstituted sample with hexane, separation was achieved on an octadecylsilyl analytical column with a mobile phase containing 0.1% trifluoroacetic acid–acetonitrile–methanol (51:46:5, v/v). Detection was performed using an ultraviolet photodiode-array detector. The signal was monitored at a wavelength of 220 nm. The assay was found to be linear and has been validated over the concentration range of 25 to 3000 μg/l for M8 and 25 to 6000 μg/l for NFV, from 500 μl of plasma. Recoveries were 98.9% (SD 8.9%), and 100.2% (SD 11.7%) for M8 and NFV, respectively. Concentrations that gave a signal-to-noise ratio of three (15 μg/l for both M8 and NFV) were selected to determine the limit of detection. The lower limit of quantification (25 μg/l for both M8 and NFV) was defined as the concentration for which the relative standard deviation and the percent deviation from the nominal concentration were lower than 20%.  相似文献   

18.
We have established an ultra-sensitive method for determination of ethanol in whole blood by headspace capillary gas chromatography (GC) with cryogenic oven trapping. After heating a blood sample containing ethanol and isobutyl alcohol (internal standard, IS) in a 7.0-ml vial at 55°C for 15 min, 5 ml of the headspace vapor was drawn into a glass syringe and injected into a GC port. All vapor was introduced into an Rtx-BAC2 wide-bore capillary column in the splitless mode at −60°C oven temperature to trap entire analytes, and then the oven temperature was programmed up to 240°C for GC measurements with flame ionization detection. The present method gave sharp peaks of ethanol and IS, and low background noise for whole blood samples. The mean partition into the gaseous phase for ethanol and IS was 3.06±0.733 and 8.33±2.19%, respectively. The calibration curves showed linearity in the range 0.02–5.0 μg/ml whole blood. The detection limit was estimated to be 0.01 μg/ml. The coefficients of intra-day and inter-day variation for spiked ethanol were 8.72 and 9.47%, respectively. Because of the extremely high sensitivity, we could measure low levels of endogenous ethanol in whole blood of subjects without drinking. The concentration of endogenous ethanol measured for 10 subjects under uncontrolled conditions varied from 0 to 0.377 μg/ml (mean, 0.180 μg/ml). Data on the diurnal changes of endogenous ethanol in whole blood of five subjects under strict food control are also presented; they are in accordance with the idea that endogenous blood ethanol is of enteric bacterial origin.  相似文献   

19.
A stable-isotope based gas chromatography–tandem mass spectrometry–negative ion chemical ionization method was developed for the determination of norepinephrine (NE) levels in small volumes (25–100 μl) of plasma. NE was stabilized in plasma by the addition of semicarbazide and spiked with deuterium-labeled norepinephrine internal standard. The analytes were isolated from the plasma by solid-phase extraction using phenylboronic acid columns and derivatized using pentafluoropropionic anhydride. The derivatized analytes were chromatographed on a capillary column and detected by tandem mass spectrometry with negative ion chemical ionization. Unparalleled sensitivity and selectivity were obtained using this detection scheme, allowing the unambiguous analysis of trace levels of NE in small-volume plasma samples. Linear standard curves were obtained for NE over a mass range from 1 to 200 pg per sample. The method had a limit of quantitation of 10 pg NE/ml plasma when using a 100-μl sample aliquot (1 pg/sample). Accuracy for the analysis of plasma samples spiked with 10 to 200 pg NE/ml typically ranged from 100±10%, with RSD values of less than 10%. The methodology was applied to determine the effect of clonidine on plasma NE levels in conscious spontaneously hypertensive rats. Administration of clonidine (30 μg/kg) produced an 80% reduction in plasma NE accompanied by a 30% reduction in heart and mean arterial pressure that persisted >90 min after drug administration. The ability to take multiple samples from individual rats allowed the time course for the effect of clonidine to be mapped out using only one group of animals.  相似文献   

20.
A simple and highly sensitive method has been developed for the determination in plasma of ciprostene, 9β-methyl-6α-carbaprostaglandin I2, using gas chromatography—mass spectrometry following solid-phase extraction on an immobilized antibody column. The anti-ciprostene antibody obtained from rabbit serum was coupled to an agarose support matrix, and the immobilized antibody thus prepared was used as an extraction phase for sample clean-up. The extracted drug was treated with pentafluorobenzyl bromide followed by bis(trimethylsilyl)trifluoroacetamide. The derivative was quantitatively analysed by negative-ion chemical ionization gas chromatography—mass spectrometry. The lower limit of quantitation was 50 pg/ml when 1 ml of human plasma was used. The plasma concentration of ciprostene in a dog treated with ciprostene at 2.5 μg/kg was determined successfully by this method.  相似文献   