首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
This study aimed to examine the reliability and sex- and age-related differences of step tests with stipulated tempos as well as to clarify useful test parameters and tempos. One hundred forty elderly people and fifty young adults conducted tapping and stepping tests, matching the tempo provided by a metronome. Both tests involve movements where the subject touches a sheet with both the right and left hands or right and left legs at a designated spot. Evaluation parameters were the time difference between the beep sound and the time at which the sheet was touched in both tests as well as two-leg support and one-leg support times in the step test. The trial-to-trial reliability of the parameters in both tests was high. The time differences of both 40 bpm tests in the elderly were larger in males than in females. In the step test, the time difference and two-leg support times of the elderly were larger, in the order of 40, 60, and 120 bpm, and the one-leg support time was less in 40 bpm than 60 bpm or 120 bpm. The one-leg support time of the young subjects was larger, in the order of 40, 60, and 120 bpm. A significant age-related difference was found in the 40 bpm and 60 bpm test, and the time difference and two-leg support time were larger in the elderly while the one-leg support time was larger in the young subjects. The time difference at 40 bpm in the elderly was larger in the step test than in the tap test. There was no significant difference between both tests in the young subjects. In conclusion, the step test with the slow tempo, because it requires a long one-leg support phase, is effective for evaluating dynamic balance in the elderly. The time difference and two-leg and one-leg support times are effective evaluation parameters of the step test.  相似文献   

2.
Intravena caval respiratory support (or membrane oxygenation) is a potential therapy for patients with acute respiratory insufficiency. A respiratory support catheter is being developed that consists of a bundle of hollow fiber membranes with a centrally positioned pulsating balloon to enhance gas exchange. This study examined the influence of vessel compliance on the gas exchange performance of the pulsating respirator, support catheter. Polyurethane elastic tubes were fabricated with compliance comparable to that measured in bovine vena cava specimens. The gas exchange performance of the respiratory catheter was studied in an in-vitro flow loop using either the model compliant tube or a rigid tube as a "mock" vena cava. Balloon pulsation enhanced gas exchange comparably in both rigid and model compliant vessels up to 120 bpm pulsation frequency. Above 120 bpm gas exchange increased with further pulsation in the rigid tube, but no additional increase in gas exchange was seen in the compliant tube. The differences above 120 bpm may reflect differences in the compliance of the elastic tube versus the natural vena cava.  相似文献   

3.
This study aimed to verify whether basketball players are able to maintain strength (handgrip), jump (countermovement jump [CMJ]), sprint (10 m and 10 m bouncing the ball [10 mBB]), and interlimb coordination (i.e., synchronized hand and foot flexions and extensions at 80, 120, and 180 bpm) performances at the end of their game. Ten young (age 15.7 ± 0.2 years) male basketball players volunteered for this study. During the friendly game, heart rate (HR), rate of perceived exertion (RPE), and rate of muscle pain (RMP) were assessed to evaluate the exercise intensity. Overall, players spent 80% of the time playing at intensities higher than 85% HRmax. Main effects (p < 0.05) for game periods emerged for HR and the number of players involved in a single action, with lower occurrence of maximal efforts and higher involvement of teammates after the first 2 periods. At the end of the game, players reported high (p < 0.05) RPE (15.7 ± 2.4) and RMP (5.2 ± 2.3) values; decreased (p < 0.05) sprint capabilities (10 m: pre = 1.79 ± 0.09 seconds, post = 1.84 ± 0.08 seconds; 10 mBB: pre = 1.81 ± 0.11 seconds, post = 1.96 ± 0.08 seconds); increased (p < 0.05) interlimb coordination at 180 bpm (pre = 33.3 ± 20.2 seconds, post = 43.9 ± 19.8 seconds); and maintained jump (pre = 35.2 ± 5.2 cm, post = 35.7 ± 5.2 cm), handgrip (pre = 437 ± 73 N, post = 427 ± 55 N), and coordinative performances at lower frequencies of executions (80 bpm: pre = 59.7 ± 1.3 seconds, post = 60.0 ± 0.0 seconds; 120 bpm: pre = 54.7 ± 12.3 seconds, post = 57.3 ± 6.7 seconds). These findings indicate that the heavy load of the game exerts beneficial effects on the efficiency of executive and attentive control functions involved in complex motor behaviors. Coaches should structure training sessions that couple intense physical exercises with complex coordination tasks to improve the attentional capabilities of the players.  相似文献   

4.

Background

Real time three dimensional (RT3D) echocardiography is an accurate and reproducible method for assessing left ventricular shape and function.

Aim

assess the feasibility and reproducibility of RT3D stress echocardiography (SE) (exercise and pharmacological) in the evaluation of left ventricular function compared to 2D.

Methods and results

One hundred eleven patients with known or suspected coronary artery disease underwent 2D and RT3DSE. The agreement in WMSI, EDV, ESV measurements was made off-line. The feasibility of RT-3DSE was 67%. The inter-observer variability for WMSI by RT3D echo was higher during exercise and with suboptimal quality images (good: k = 0.88; bad: k = 0.69); and with high heart rate both for pharmacological (HR < 100 bpm, k = 0.83; HR ≥ 100 bpm, k = 0.49) and exercise SE (HR < 120 bpm, k = 0.88; HR ≥ 120 bpm, k = 0.78). The RT3D reproducibility was high for ESV volumes (0.3 ± 14 ml; CI 95%: -27 to 27 ml; p = n.s.).

Conclusions

RT3DSE is more vulnerable than 2D due to tachycardia, signal quality, patient decubitus and suboptimal resting image quality, making exercise RT3DSE less attractive than pharmacological stress.  相似文献   

5.
The pig as a model of tachycardia and dilated cardiomyopathy   总被引:2,自引:0,他引:2  
Chronic Supraventricular Tachycardia (SVT) can produce a dilated cardiomyopathy which has a poorly understood association with ventricular dysfunction in humans and animals. The purpose of this study was to produce a model of chronic SVT and dilated cardiomyopathy using swine, which have a cardiac anatomy similar to man. Eight pigs were implanted with chronic atrial catheters and a pacemaker, with four additional sham-operated pigs serving as controls. We examined ventricular function and morphology at baseline (120 +/- 3 bpm), pacing baseline (240 bpm), and at 1, 2 and 3 weeks of rapid atrial pacing (240 bpm). Ventricular ejection fractions fell significantly from baseline following 1 week (left: 38 +/- 3% vs baseline 61 +/- 1%; right: 31 +/- 5% vs baseline 56 +/- 1%; p less than 0.05) and deteriorated further by 3 weeks of SVT (left: 26 +/- 4%, right: 19 +/- 3%; p less than 0.05). Significant biventricular chamber dilation developed by 2 weeks of SVT (left: 50 +/- 5 cc vs paced baseline 27 +/- 2 cc; right: 67 +/- 6 cc vs paced baseline 28 +/- 3 cc; p less than 0.05) and continued to increase by week 3 of SVT (left: 66 +/- 11 cc; right: 78 +/- 8 cc; p less than 0.05). Five additional paced pigs, without chronic atrial catheters, were followed using echocardiography.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

6.
《Free radical research》2013,47(11):1362-1370
Abstract

We sought to evaluate lysophosphatidic acid (LPA) signaling improvement in lung development by assessing the expression of autotaxin and LPA receptor 1 and 3 (LPAR1 and LPAR3) in the neonatal rat lung during normal perinatal development and in response to hyperoxia. In the developmental study, rats were sacrificed on days 17, 19, and 21 of gestation; on postnatal days 1, 4, and 7; and at adulthood (postnatal 9 weeks). In the hyperoxia study, 42 postnatal 4-day-old rat pups were divided into seven groups and exposed to either 85% O2 for 24, 72, or 120 h or room air for 0, 24, 72, or 120 h. The rats were then euthanized after 0, 24, 72, and 120 h of exposure. Immunofluorescence demonstrated that autotaxin, LPAR1, and LPAR3 proteins were broadly colocalized in airway epithelial cells, but mainly distributed in vascular endothelial and mesenchymal cells during the first postnatal week. The expression of autotaxin, LPAR1, and LPAR3 were increased during late gestation and then decreased after birth. Autotaxin expression and enzymatic activity were significantly increased at 72 and 120 h after exposure to hyperoxia. LPAR1 and LPAR3 expression was also increased after 120 h of hyperoxic exposure. These findings suggest that LPA-associated molecules were upregulated at birth and induced by hyperoxia in the developing rat lung. Therefore, the LPA pathway may be involved in normal lung development, including vascular development, as well as wound-healing processes of injured neonatal lung tissue, which is at risk of neonatal hyperoxic acute lung injury.  相似文献   

7.
The lysozyme activity, alternative complement activity (ACH50), respiratory burst, SOD (superoxide dismutase) activity and phagocytic activity of orange-spotted grouper Epinephelus coicoides were examined when the fish were injected intraperitoneally with sodium alginate at 10, 20, 30mgkg-1 and iota-carrageenan at 10, 20, 30mgkg-1, respectively after 24, 72 and 120 h. Serum ACH50 increased directly with dose after 24 and 72 h for both sodium alginate and iota-carrageenan treatments. The fish that received sodium alginate at 20mgkg-1 after 24 and 72 h, and the fish that received iota-carrageenan after 72 and 120 h showed significantly increased respiratory burst, SOD activity and phagocytic activity, respectively. In another experiment, E. coicoides which had been injected individually with sodium alginate and iota-carrageenan at 10, 20, 30mgkg-1, were challenged with Vibrio alginolyticus at 1.8x10(9) colony-forming units (cfu)fish-1 and then placed in seawater of 33 per thousand. The survival of fish that received sodium alginate at 20mgkg-1, and the fish that received iota-carrageenan at 30mgkg-1 was significantly higher than that of fish which received saline and the control fish after 48 h as well as at the termination of the experiment (120 h after the challenge). It is therefore concluded that E. coicoides which received sodium alginate at 20mgkg-1 or iota-carrageenan at 30mgkg-1 increased the non-specific immune response and resistance from V. alginolyticus infection.  相似文献   

8.
The aim of this study was to determine whether the increase in blood volume in resting muscle during moderately prolonged exercise is related to heart rate (HR) upward drift. Eight healthy men completed both arm-cranking moderately prolonged exercise (APE) and leg-pedaling moderately prolonged exercise (LPE) for 30 min. Exercise intensity was 120 bpm of HR that was determined by ramp incremental exercise. During both APE and LPE, HR significantly increased from 3 to 30 min (from 108±9.3 to 119±12 bpm and from 112±8.9 to 122±11 bpm, respectively). However, there was no significant difference between HR in APE and that in LPE. Oxygen uptake was maintained throughout the two exercises. Skin blood flow, deep temperature, and total Hb (blood volume) in resting muscle continuously increased for 30 min of exercise during both APE and LPE. During both APE and LPE, there was a significant positive correlation between total Hb and deep temperature in all subjects. Moreover, there was a significant positive correlation between HR and total Hb (in seven out of eight subjects) during LPE. However, during APE, there was no positive correlation between HR and total Hb (r=0.391). These findings suggest that an increase of blood pooling in resting muscle could be proposed as one of the mechanisms underlying HR upward drift during moderately prolonged exercise.  相似文献   

9.
Ketosteroid isomerase (KSI) from Pseudomonas putida biotype B is a homodimeric enzyme catalyzing an allylic isomerization of Delta(5)-3-ketosteroids at a rate of the diffusion-controlled limit. The dimeric interactions mediated by Arg72, Glu118, and Asn120, which are conserved in the homologous KSIs, have been characterized in an effort to investigate the roles of the conserved interface residues in stability, function and structure of the enzyme. The interface residues were replaced with alanine to generate the interface mutants R72A, E118A, N120A and E118A/N120A. Equilibrium unfolding analysis revealed that the DeltaG(U)(H(2)O) values for the R72A, E118A, N120A, and E118A/N120A mutants were decreased by about 3.8, 3.9, 7.8, and 9.5 kcal/mol, respectively, relative to that of the wild-type enzyme. The interface mutations not only decreased the k(cat)/K(M) value by about 8- to 96-fold, but also increased the K(D) value for d-equilenin, a reaction intermediate analogue, by about 7- to 17.5-fold. The crystal structure of R72A determined at 2.5 A resolution and the fluorescence spectra of all the mutants indicated that the interface mutations altered the active-site geometry and resulted in the decreases of the conformational stability as well as the catalytic activity of KSI. Taken together, our results strongly suggest that the conserved interface residues contribute to stabilization and structural integrity of the active site in the dimeric KSI.  相似文献   

10.
The synthesis and characterization of complexes [(η(6)-arene)Ru(N,N')X][PF(6)], where arene is para-cymene (p-cym), biphenyl (bip), ethyl benzoate (etb), hexamethylbenzene (hmb), indane (ind) or 1,2,3,4-tetrahydronaphthalene (thn), N,N' is 2,2'-bipyrimidine (bpm) and X is Cl, Br or I, are reported, including the X-ray crystal structures of [(η(6)-p-cym)Ru(bpm)I][PF(6)], [(η(6)-bip)Ru(bpm)Cl][PF(6)], [(η(6)-bip)Ru(bpm)I][PF(6)] and [(η(6)-etb)Ru(bpm)Cl][PF(6)]. Complexes in which N,N' is 1,10-phenanthroline (phen), 1,10-phenanthroline-5,6-dione or 4,7-diphenyl-1,10-phenanthroline (bathophen) were studied for comparison. The Ru(II) arene complexes undergo ligand-exchange reactions in aqueous solution at 310?K; their half-lives for hydrolysis range from 14 to 715?min. Density functional theory calculations on [(η(6)-p-cym)Ru(bpm)Cl][PF(6)], [(η(6)-p-cym)Ru(bpm)Br][PF(6)], [(η(6)-p-cym)Ru(bpm)I][PF(6)], [(η(6)-bip)Ru(bpm)Cl][PF(6)], [(η(6)-bip)Ru(bpm)Br][PF(6)] and [(η(6)-bip)Ru(bpm)I][PF(6)] suggest that aquation occurs via an associative pathway and that the reaction is thermodynamically favourable when the leaving ligand is I?>?Br?≈?Cl. pK (a)* values for the aqua adducts of the complexes range from 6.9 to 7.32. A binding preference for 9-ethylguanine (9-EtG) compared with 9-ethyladenine (9-EtA) was observed for [(η(6)-p-cym)Ru(bpm)Cl][PF(6)], [(η(6)-hmb)Ru(bpm)Cl](+), [(η(6)-ind)Ru(bpm)Cl](+), [(η(6)-thn)Ru(bpm)Cl](+), [(η(6)-p-cym)Ru(phen)Cl](+) and [(η(6)-p-cym)Ru(bathophen)Cl](+) in aqueous solution at 310?K. The X-ray crystal structure of the guanine complex [(η(6)-p-cym)Ru(bpm)(9-EtG-N7)][PF(6)](2) shows multiple hydrogen bonding. Density functional theory calculations show that the 9-EtG adducts of all complexes are thermodynamically preferred compared with those of 9-EtA. However, the bmp complexes are inactive towards A2780 human ovarian cancer cells. Calf thymus DNA interactions for [(η(6)-p-cym)Ru(bpm)Cl][PF(6)] and [(η(6)-p-cym)Ru(phen)Cl][PF(6)] consist of weak coordinative, intercalative and monofunctional coordination. Binding to biomolecules such as glutathione may play a role in deactivating the bpm complexes.  相似文献   

11.
This report examines the role of African swine fever virus (ASFV) structural protein pE120R in virus replication. Immunoelectron microscopy revealed that protein pE120R localizes at the surface of the intracellular virions. Consistent with this, coimmunoprecipitation assays showed that protein pE120R binds to the major capsid protein p72. Moreover, it was found that, in cells infected with an ASFV recombinant that inducibly expresses protein p72, the incorporation of pE120R into the virus particle is dependent on p72 expression. Protein pE120R was also studied using an ASFV recombinant in which E120R gene expression is regulated by the Escherichia coli lac repressor-operator system. In the absence of inducer, pE120R expression was reduced about 100-fold compared to that obtained with the parental virus or the recombinant virus grown under permissive conditions. One-step virus growth curves showed that, under conditions that repress pE120R expression, the titer of intracellular progeny was similar to the total virus yield obtained under permissive conditions, whereas the extracellular virus yield was about 100-fold lower than in control infections. Immunofluorescence and electron microscopy demonstrated that, under restrictive conditions, intracellular mature virions are properly assembled but remain confined to the replication areas. Altogether, these results indicate that pE120R is necessary for virus dissemination but not for virus infectivity. The data also suggest that protein pE120R might be involved in the microtubule-mediated transport of ASFV particles from the viral factories to the plasma membrane.  相似文献   

12.
The potential role of endogenous sex hormones in regulating hypothalamo-pituitary-adrenal (HPA) axis function was investigated after a single injection of endotoxin in adult (8 week old) BALB/c mice of both sexes. The effect of LPS on plasma ACTH, corticosterone (B), testosterone and oestradiol (E) levels and on anterior pituitary (AP) ACTH and adrenal B contents at different times after treatment was studied. The results indicate that: (a) basal B but not ACTH plasma levels were significantly higher in female than in male mice; (b) LPS significantly increased both ACTH and B plasma levels over the baseline 2 h after injection, both hormone levels being higher in female than in male mice; (c) although plasma ACTH concentrations recovered the basal value at 72 h after LPS in animals of both sexes, plasma B levels returned to the baseline only at 120 h after treatment; (d) E plasma levels significantly increased 2 h after LPS and returned to the baseline at 72 h post-treatment, in both sexes; (e) at 2 h after LPS, testosterone plasma levels significantly decreased in male mice and increased in female mice, recovering the baseline level at 120 and 72 h after LPS, respectively; (f) AP ACTH content was similar in both sexes in basal condition and it was significantly diminished 72 h post-treatment without sex difference; whereas AP ACTH returned to basal content 120 h after LPS in males, it remained significantly decreased in females; (g) basal adrenal B content was higher in female than in male mice, and it significantly increased in both sexes 2 h post-LPS, maintaining this sex difference. Whereas adrenal B returned to basal content 72 h after treatment in male mice, it remained significantly enhanced up to 120 h post-LPS in female animals. The data demonstrate the existence of a clear sexual dimorphism in basal condition and during the acute phase response as well as in the recovery of the HPA axis function shortly after infection.  相似文献   

13.

Background

Predischarge defibrillation threshold testing is often performed a few days after ICD implantation in order to validate defibrillation thresholds obtained at the time of implant. Ventricular fibrillation is induced with such testing and causes an increase in serum Brain Natriuretic Peptide (BNP) levels. BNP is an indicator for cardiac stress. We wanted to examine the feasibility to alter the trend of BNP after predischarge testing in VVI, DDD and CRT ICD''s.

Methods

We measured BNP before predischarge testing and 5, 10, 20 and 40 minutes after predischarge testing in 13 groups with each 20 patients. We evaluated patients without post shock pacing and patients with a post shock pacing frequency of 60, 70, 80, 90 and 100 bpm and a duration of 30 and 60 sec as well as a post shock pacing frequency of 80 and 90 bpm and a duration of 120 sec post shock pacing.

Results

Patients without post shock pacing showed the highest BNP during the follow-up. The percentage values of BNP increased consistent significantly after 5 minutes compared with BNP before predischarge testing. The percentage values of BNP trend was significantly lower with a post shock pacing of 90 bpm and duration of 60 sec. In addition, we excluded a cardiac necrosis by predischarge testing because of similar values of myoglobin, cardiac troponin I and creatine kinase during the follow-up.

Conclusions

Our results suggested that post shock pacing with 90 bpm and duration of 60 sec as the best optimized post shock pacing frequency and duration for VVI, DDD and CRT ICD''s. A reduction of cardiac stress is going to be achieved with the optimization of the post shock pacing frequency and duration.  相似文献   

14.
IntroductionCardiac autonomic system modulation by endocardial ablation targeting atrial ganglionated plexi (GP) is an alternative strategy in selected patients with severe functional bradyarrhythmias, although no consensus exists on the best ablation strategy. The aim of this study was to evaluate if a simplified approach by a purely anatomical guided ablation of just the atrial right GP is enough for the treatment of these patients.MethodsWe prospectively enrolled patients with significant functional bradyarrhythmias and performed endocardial ablation purely guided by 3D electroanatomic mapping directed at the atrial right GP and accessed parameters of parasympathetic modulation and recurrence of bradyarrhythmias.ResultsThirteen patients enrolled (76.9% male, median age 51, 42–63 years). After ablation, a median RR interval shortening of 28.3 (25.6–40.3)% occurred (1111, 937.5–1395.4 ms to 722.9, 652.2–882.4 ms, p = 0.0002). The AH interval also shortened (19, 10.5–35.7%) significantly after the procedure (115, 105–122 ms to 85, 71–105 ms, p = 0.0023) as well as Wenckebach cycle length (11.1, 5.9–17.8% shortening) from 450, 440–510 ms to 430, 400–460 ms, p = 0.0127. On 24-h Holter monitoring there was significant increase in heart rates (HR) of patients after ablation (minimal HR increased from 34 (26–43)bpm to 49 (43–56)bpm, p = 0,0102 and mean HR from 65 (47–72)bpm to 78 (67–87)bpm, p = 0.0004). No patients had recurrence of symptoms or significant bradyarrhythmias during a median follow-up of 8.4 months.ConclusionsA purely anatomic guided procedure directed only at the atrial right ganglionated plexi seems to be enough as a therapeutic approach for cardioneuroablation in selected patients with significant functional bradyarrhythmias.  相似文献   

15.
对鸡腿蘑多糖的结构进行检测,并在此基础上探讨结构与活性的关系,对深度发掘鸡腿蘑多糖的功效具有重要意义.制备发酵时间为72 h、96 h和120 h的鸡腿蘑胞外粗多糖,采用PMP柱前衍生化-HPLC法分析其单糖组成,结果表明发酵72 h、96 h和120 h胞外多糖均由D-甘露糖、L-鼠李糖、D-葡萄糖、D-半乳糖、D-...  相似文献   

16.
Cao PJ  Paeng DG  Shung KK 《Biorheology》2001,38(1):15-26
The "black hole" phenomenon was further investigated with porcine whole blood under pulsatile flow conditions in a straight rigid tube 120 cm long and of 0.95 cm diameter. A modified Aloka 280 commercial scanner with a 7.5 MHz linear array was used to collect the radio frequency (RF) signal of backscattering echoes from the blood inside the tube. The transducer was located downstream from the entrance and parallel to the longitudinal direction of the tube. The experimental results showed that higher hematocrits enhanced the black hole phenomenon, leading to a more apparent and larger diameter black hole. The black hole was not apparent at hematocrits below 23%. The highest hematocrit used in the experiment was 60%. Beat rates of 20, 40 and 60 beats per minute (bpm) were used, and the black hole became weaker in amplitude and smaller in diameter when the peak flow velocity was increased at each beat rate. These results are consistent with the suggestion in previous work that the black hole arises from insufficient aggregation of red blood cells (RBCs) at the center of the tube because of the low shear rate. At 20 and 40 bpm, the peak flow velocity ranges were 10 approximately 25 cm/s and 18 approximately 27 cm/s, respectively. The black hole was very clear at the minimal peak flow velocity but almost disappeared at the maximal velocities for each beat rate. At 60 bpm, experiments were only performed at one peak flow velocity of 31 cm/s and the black hole was clear. The results showed that the black hole was more pronounced at higher beat rates when the peak velocity was the same. This phenomenon cannot be explained by previous hypotheses. Acceleration seems to be the only flow parameter that varies at different beat rates when peak velocities are the same. Therefore, the influence of acceleration on the structural organization and orientation of RBC rouleaux might be another factor involved in the formation of the black hole in addition to the shear rate. As the entrance length was changed from 110 to 15 diameters (D) in seven steps at the hematocrit of 60%, it was found that a position farther downstream yielded a black hole with a greater contrast relative to the surrounding region, while the backscattering power at the central hypoechoic zone did not increase with increasing entrance length.  相似文献   

17.
PurposeTo investigate whether electrocardiogram (ECG)-gated single- and dual-heartbeat computed tomography coronary angiography (CTCA) with automatic exposure control (AEC) yields images with uniform image noise at reduced radiation doses.Materials and methodsUsing an anthropomorphic chest CT phantom we performed prospectively ECG-gated single- and dual-heartbeat CTCA on a second-generation 320-multidetector CT volume scanner. The exposure phase window was set at 75%, 70–80%, 40–80%, and 0–100% and the heart rate at 60 or 80 or corr80 bpm; images were reconstructed with filtered back projection (FBP) or iterative reconstruction (IR, adaptive iterative dose reduction 3D). We applied AEC and set the image noise level to 20 or 25 HU. For each technique we determined the image noise and the radiation dose to the phantom center.ResultsWith half-scan reconstruction at 60 bpm, a 70–80% phase window- and a 20-HU standard deviation (SD) setting, the imagenoise level and -variation along the z axis manifested similar curves with FBP and IR. With half-scan reconstruction, the radiation dose to the phantom center with 70–80% phase window was 18.89 and 12.34 mGy for FBP and 4.61 and 3.10 mGy for IR at an SD setting SD of 20 and 25 HU, respectively. At 80 bpm with two-segment reconstruction the dose was approximately twice that of 60 bpm at both SD settings. However, increasing radiation dose at corr80 bpm was suppressed to 1.39 times compared to 60 bpm.ConclusionAEC at ECG-gated single- and dual-heartbeat CTCA controls the image noise at different radiation dose.  相似文献   

18.
PurposeTo investigate differences in image-to-image variations between full- and half-scan reconstruction on myocardial CT perfusion (CTP) study.MethodsUsing a cardiac phantom we performed ECG-gated myocardial CTP on a second-generation 320-multidetector CT volume scanner. The heart rate was set at 60 bpm; once per second for a total of 24 s were performed. CT images were acquired at 80- and 120 kVp and subjected to full- and half-scan reconstruction. On images acquired at the same slice level we then measured image-to-image variations, coefficients of variance (CV), and image noise.ResultsThe image-to-image variations with full- and half-scan reconstruction were 1.3 HU vs. 27.2 HU at 80 kVp (p < 0.001) and 0.70 HU vs. 9.3 HU at 120 kVp (p < 0.001) even though the mean HU value was almost the same for both reconstruction methods. The CV of 80- and 120-kVp images of the left ventricular cavity decreased by 0.16% and 0.17%, respectively, with full-scan reconstruction; with half-scan reconstruction it decreased by 3.34% and 2.30%, respectively. Compared with half-scan reconstruction, the image noise was reduced by 27.2% at 80 kVp and by 28.0% at 120 kVp with full-scan reconstruction.ConclusionMyocardial CTP with full-scan reconstruction substantially decreased image-to-image variations and provided accurate CT attenuation.  相似文献   

19.
The retention time of the estrogen receptor in the nucleus of target cells after antiestrogen treatment has been shown to be longer than after estradiol. This paper describes the accumulation of nuclear estrogen receptors and the obtention of estrogenic responses (i.e. synthesis of cytosolic progesterone receptors and DNA) in the rat uterus after tamoxifen treatment in the presence or absence of estradiol. One-week ovariectomized adult rats were implanted with a silicone elastomer capsule containing corn oil or 25 micrograms estradiol/capsule (0 h). 48 h after implantation rats were injected with corn oil or 2 mg tamoxifen/kg and decapitated at 72, 96 or 120 h after implantation. In parallel experiments the implants were removed just before the injections of tamoxifen or oil. Tamoxifen injected into rats implanted with oil increased both the occupied nuclear receptors and the progesterone receptors at 96 h. In rats implanted with estradiol, tamoxifen did not increase the occupied nuclear receptors and decreased the levels of progesterone receptor and DNA at 96 h. In rats whose estradiol implants were removed at 48 h tamoxifen did not change the level of occupied nuclear receptors at 72 h but it increased them abruptly at 96 and 120 h. In these rats progesterone receptors decreased at 72 h but they increased at 96 and 120 h, and DNA decreased at 120 h to a lower level than before implantation. The results suggest that when estradiol is acting, tamoxifen is not able to increase the level of occupied estrogen receptor and it acts as an antiestrogen by decreasing the high level of progesterone receptors previously induced by estradiol. When estradiol is not acting tamoxifen behaves as a partial estrogen agonist by inducing progesterone receptors. However, the antiestrogenic action of tamoxifen on the rat uterus DNA does not seem to be affected by estradiol.  相似文献   

20.
PurposeTo investigate the effects of heart beat rate (bpm), vessel angulation and acquisition protocol on the estimation accuracy of calcified stenosis using a dual-energy CT scanner.MethodsA thorax semi-anthropomorphic phantom coupled with a motion simulator and a vessel phantom representing a 50% coronary artery calcified stenosis, were used. Electrocardiograph (ECG)-synchronized acquisitions were performed at different bpms. Acquisitions were performed using A, B, and C single-energy and D dual-energy protocols. Protocol A was prospective ECG-triggered axial and protocols B and C were retrospective single- and two-segment reconstruction ECG-gated helical acquisitions. Protocol D was prospective ECG-triggered axial acquisition. The vessel phantom was placed at two angulations relative to z-axis. Images were reconstructed using all available kernels with iterative reconstruction. Stenosis-percentage was estimated using the CT vendor’s vessel analysis tool. Effective dose (ED) was estimated using the dose-length product method.ResultsIn protocols A, B, and C, measured Stenosis-percentage increased with bpm. Stenosis-percentage estimate ranged from 56.8% at 40 bpm to 62.6% at 100 bpm. In protocol D, Stenosis-percentage ranged from 59.3% at 40 bpm to 54.8% at 80 bpm. Stenosis-percentage was overestimated on respect to the nominal value in most kernels. The detail kernel exhibited the highest accuracy. Stenosis-percentage was not affected by the vessel angulation. ED for protocols A, B, C, and D was 2.4 mSv, 5.1 mSv, 5.5 mSv, and 2.8 mSv, respectively.ConclusionsUse of the dual-energy cardiac CT examination protocol along with the detail kernel is recommended for a more accurate assessment of Stenosis-percentage.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号