首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Human exposure to magnetic fields, increased through use of new technologies like magnetic resonance imaging (MRI), has prompted investigations into possible effects of static magnetic fields (SMFs) on cellular processes. However, controversy still remains between many studies, which likely results from a lack of uniformity across experimental parameters, including the length of magnetic field exposure, the strength of the magnetic field, and the cell type or organism under investigation. The purpose of this research was to monitor effects of SMF exposure using real‐time luminescence photometry. The study investigated the potential interaction of a 100 mT SMF on a heat shock protein (hsp70)/luciferase reporter construct in stably transfected NIH3T3 cells. Changes in heat shock promoter activation following 100 mT SMF exposure were analyzed and detected as bioluminescence in real‐time. Two heat parameters were considered in combination with sham‐ and 100 mT‐exposed experiments: no heat or 1,800 s heat. As expected, there was a significant increase in bioluminescence in response to 1,800 s of heat alone. However, no significant difference in average hsp70 promoter activation between sham and 100 mT experiments was observed for no heat or 1,800 s heat experiments. Therefore, a 100 mT SMF was shown to have no effect on the activation of the heat shock protein promoter during SMF exposure or when SMF exposure was combined with a heat insult. J. Cell. Biochem. 108: 956–962, 2009. © 2009 Wiley‐Liss, Inc.  相似文献   

2.
The aim of this study was to investigate the effect of static magnetic fields (SMF) on reactive oxygen species induced by X‐ray radiation. The experiments were performed on lymphocytes from male albino Wistar rats. After exposure to 3 Gy X‐ray radiation (with a dose rate of 560 mGy/min) the measurement of intracellular reactive oxygen species in lymphocytes, using a fluorescent probe, was done before exposure to the SMF, and after 15 min, 1 and 2 h of exposure to the SMF or a corresponding incubation time. For SMF exposure, 0 mT (50 µT magnetic field induction opposite to the geomagnetic field) and 5 mT fields were chosen. The trend of SMF effects for 0 mT was always opposite that of 5 mT. The first one decreased the rate of fluorescence change, while the latter one increased it. Bioelectromagnetics 34:333–336, 2013. © 2012 Wiley Periodicals, Inc.  相似文献   

3.
We investigated the relative contributions of temperature and a 300 kHz alternating magnetic field (AMF) on magnetic hyperthermia treatment (MHT). Our system consisted of an induction coil, which generated AMF by electric current flow, and a newly developed, temperature‐controlled circulating water‐jacketed glass bottle placed inside the coil. The AMF generator operated at a frequency of 300 kHz with variable field strength ranging from 0 to 11 mT. Four treatment conditions were employed: (A) control (37 °C, 0 mT), (B) AMF exposure (37 °C, 11 mT), (C) hyperthermia (46 °C, 0 mT), and (D) hyperthermia plus AMF exposure (46 °C, 11 mT) for 30 min. Cell viability and apoptotic death rate were estimated. The relative contributions or interactions of hyperthermia (46 °C) and AMF (11 mT) on MHT were evaluated using 2 × 2 factorial experiment analysis. Group A was statistically different (P < 0.05) from each of the other treatments. The observed effects on both cell viability and apoptotic cell death were influenced by temperature (97.36% and 92.15%, respectively), AMF (1.78% and 4.99%, respectively), and the interactions between temperature and AMF (0.25% and 2.36%, respectively). Thus, the effect of hyperthermia was significant. Also, AMF exposure itself might play a role in MHT, although these observations were made in vitro. These findings suggest a possible presence of an AMF effect during clinical magnetic hyperthermia. Bioelectromagnetics 34:95–103, 2013. © 2012 Wiley Periodicals, Inc.  相似文献   

4.
Static magnetic fields (SMFs) and time-varying electromagnetic fields exposure is necessary to obtain the diagnostic information regarding the structure of patient's tissues, by the use of magnetic resonance imaging (MRI) scanners. A diagnostic procedure may also include the administration of pharmaceuticals called contrast, which are to be applied to a patient during the examination. The nurses involved in administering contrast into a patient during the pause in examination are approaching permanently active magnets of MRI scanners and are exposed to SMF. There were performed measurements of spatial distribution of SMF in the vicinity of MRI magnets and parameters of personal exposure of nurses (i.e. individual exposimetric profiles of variability in time of SMF affecting the nurse who is performing tasks in the vicinity of magnet, characterized by statistical parameters of recorded magnetic flux density affecting the nurse). The SMF exposure in the vicinity of various MRI magnets depends on both magnetic flux density of the main field B 0 (applicable to a patient) and the construction of the scanner, but the most important factor determining the workers' exposure is the work practice. In the course of a patient's routine examination in scanners of B 0 = 1.5 T, the nurses are present over ~0.4–2.9 min in SMF exceeding 0.03% of B 0 (i.e. 0.5 mT), but only sometimes they are present in SMF exceeding 5% of B 0 (i.e. 75 mT). When patients need more attention because of their health status/condition, the nurses' exposure may be significantly longer – it may even exceed 10 min and 30% of B 0 (i.e. 500 mT). We have found that the level of exposure of nurses to SMF may vary from < 5% of the main field (a median value: 0.5–1.5%; inter-quartile range: 0.04–8.8%; max value: 1.3–12% of B 0) when a patient is moved from the magnets bore before contrast administration, up to the main field level (B 0) when a patient stays in the magnets bore and nurse is crawling into the bore.  相似文献   

5.
Experimental autoimmune encephalomyelitis (EAE) reproduces a multiple sclerosis (MS)-like experimental model. The main objective was to evaluate the effect of extremely low-frequency electromagnetic fields (EL-EMF) application, like a paradigm of transcranial magnetic stimulation (TMS) in the development of EAE. Rats were injected with a single dose of 150?μg of myelin oligodendrocyte glycoprotein (MOG, fragment 35–55) to produce experimental MS. To assess the effect of TMS application in EAE, the rats were treated with TMS (60?Hz and 0.7?mT) for 2?h in the morning, once a day, 5 days a week, during 3 weeks. TMS was applied to the head. The effect of TMS on EAE was evaluated as motor symptoms and, oxidative and cell damage. The data showed that MOG induced motor symptoms as tail paralysis and limb paresis/paralysis, oxidative stress and cell death similar to MS when compared with control animals. Importantly, TMS application attenuated motor symptoms, oxidative and cell damage, whereas it increased antioxidant system. Our findings suggest that: (i) MOG reproduces an experimental model of MS characterised by oxidative and cell damage; and (ii) TMS application decreases oxidative stress and cell death induced by MOG.  相似文献   

6.
In the present experiment, the effect of a single 30 min inhomogeneous static magnetic field (SMF) exposure on thermal pain threshold (TPT) was examined in 15 young healthy human volunteers. The SMF had a maximum peak‐to‐peak amplitude of 330 mT with a maximum gradient of 13.2 T/m. In either of two experimental sessions (SMF or SHAM), four blocks of 12 TPT trials were carried out under SMF or SHAM exposure on all fingertips of the dominant hand, excluding the thumb. TPT and visual analog scale (VAS) data were recorded at 0, 15, and 30 min exposure time, and 30 min following exposure. SMF treatment resulted in a statistically significant increase in TPT during the entire exposure duration and diminished within‐block thermal habituation, leaving pain perception unchanged. These results indicate that SMF‐induced peripheral neuronal or circulatory mechanisms may be involved in the observed TPT increase by setting the pain fibre adaptation potential to higher levels. Bioelectromagnetics 32:131–139, 2011. © 2010 Wiley‐Liss, Inc.  相似文献   

7.
This study investigated the spatial magnetic gradient effects of static magnetic fields (SMF) on endothelial tubular formation by applying the maximum spatial gradient to a target site of culture wells for cell growth. The respective maximum values of magnetic flux density (B(max)), magnetic flux gradient (G(max)) and the magnetic force product of the magnetic flux density and its gradient (a parameter of magnetic force) were 120 mT, 28 mT/mm and 1428 mT(2)/mm. The effects of gradient SMF on tubular formation were compared with those of uniform SMF that has no spatial gradients on the entire bottom area of culture wells. Five experimental groups of 25 samples each were examined: (1) sham exposure (control); (2) peak gradient exposure in the peripheral part; (3) peak gradient exposure in the central part; (4) uniform exposure to 20 mT; (5) uniform exposure to 120 mT. The SMF or sham exposure was carried out for 10 days. Photomicrographs of tubular cells, immunostained with an anti-platelet-endothelial cell adhesion molecule-1 (PECAM-1 [CD31]) antibody as a pan-endothelial marker, were analyzed after the 10-day culture. Gradient SMF in the peripheral or central part was found to significantly promote tubular formation in terms of the area density and length of tubules in each peak gradient/force part of the wells, compared with the sham exposure. In contrast, uniform SMF did not induce any significant change in the tubular formation. These findings suggest that tubule formation can be promoted by applying the peak gradient/force to a target site of culture wells.  相似文献   

8.
It is believed that static magnetic fields (SMF) cannot affect the pattern formation of the Belousov-Zhabotinsky (BZ) reaction, which has been frequently studied as a simplified experimental model of a nonequilibrium open system, because SMF produces no induced current and the magnetic force of SMF far below 1 T is too low to expect the effects on electrons in the BZ reaction. In the present study, we examined whether the velocity of chemical waves in the unstirred BZ reaction can be affected by a moderate-intensity SMF exposure depending on the spatial magnetic gradient. The SMF was generated by a parallel pair of attracting rectangular NdFeB magnets positioned opposite each other. The respective maximum values of magnetic flux density (B(max)), magnetic flux gradient (G(max)), and the magnetic force product of the magnetic flux density its gradient (a magnetic force parameter) were 206 mT, 37 mT/mm, and 3,000 mT(2)/mm. The ferroin-catalyzed BZ medium was exposed to the SMF for up to 16 min at 25 degrees C. The experiments demonstrated that the wave velocity was significantly accelerated primarily by the magnetic gradient. The propagation of the fastest wave front indicated a sigmoid increase along the peak magnetic gradient line, but not along the peak magnetic force product line. The underlying mechanisms of the SMF effects on the anomalous wave propagation could be attributed primarily to the increased concentration gradient of the paramagnetic iron ion complexes at the chemical wave fronts induced by the magnetic gradient.  相似文献   

9.
Transcranial magnetic stimulation (TMS) is a stimulation method in which a magnetic coil generates a magnetic field in an area of interest in the brain. This magnetic field induces an electric field that modulates neuronal activity. The spatial distribution of the induced electric field is determined by the geometry and location of the coil relative to the brain. Although TMS has been used for several decades, the biophysical basis underlying the stimulation of neurons in the central nervous system (CNS) is still unknown. To address this problem we developed a numerical scheme enabling us to combine realistic magnetic stimulation (MS) with compartmental modeling of neurons with arbitrary morphology. The induced electric field for each location in space was combined with standard compartmental modeling software to calculate the membrane current generated by the electromagnetic field for each segment of the neuron. In agreement with previous studies, the simulations suggested that peripheral axons were excited by the spatial gradients of the induced electric field. In both peripheral and central neurons, MS amplitude required for action potential generation was inversely proportional to the square of the diameter of the stimulated compartment. Due to the importance of the fiber's diameter, magnetic stimulation of CNS neurons depolarized the soma followed by initiation of an action potential in the initial segment of the axon. Passive dendrites affect this process primarily as current sinks, not sources. The simulations predict that neurons with low current threshold are more susceptible to magnetic stimulation. Moreover, they suggest that MS does not directly trigger dendritic regenerative mechanisms. These insights into the mechanism of MS may be relevant for the design of multi-intensity TMS protocols, may facilitate the construction of magnetic stimulators, and may aid the interpretation of results of TMS of the CNS.  相似文献   

10.
Static magnetic fields (SMF) in the millitesla (mT) range have been reported to modulate microcirculatory hemodynamics and/or blood pressure (BP) under pharmacologically modified state in mammals. This study was designed to investigate the acute effects of local application of a SMF to neck or pelvic region under pharmacologically modulated BP; norepinephrine (NE)-induced hypertension as well as an L-type voltage-gated Ca(2+) channel blocker, nicardipine (NIC)-induced hypotension in conscious rabbits. Magnetic flux densities were up to 5.5 mT and the spatial magnetic gradient peaked in neck (carotid sinus baroreceptor) region at the level of approximately 0.06 mT/mm. The duration of exposure was 30 min (including 10 min of pretreatment) and the effects on BP were investigated up to 100 min postexposure. Baroreflex sensitivity (BRS) was estimated from invasive recordings of systolic BP and pulse interval. Neck exposure to 5.5 mT significantly attenuated the pharmacologically induced vasoconstriction or vasodilation, and subsequently suppressed the increase or decrease in BP compared with sham exposure. In contrast, pelvic exposure to 5.5 mT did not significantly antagonized NE-elevated BP or NIC-reduced BP. The neck exposure to 5.5 mT has a biphasic and restorative effect on vascular tone and BP acting to normalize the tone and BP. The neck exposure to 5.5 mT caused a significant increase in BRS in NE-elevated BP compared with sham exposure. The buffering effects of the SMF on increased hemodynamic variability under NE-induced high vascular tone and NIC-induced low vascular tone might be, in part, dependent on baroreflex pathways, which could modulate NE-mediated response in conjunction with Ca(2+) dynamics.  相似文献   

11.
The purpose of this study was to investigate the effects of moderate-intensity static magnetic field (SMF) on diabetic mice. We studied the effects of SMF on blood glucose of normal mice by starch tolerance and glucose tolerance tests. Then, we evaluated the effects of SMF on blood glucose of diabetic mice by establishing alloxan-induced type 1 diabetic mice and high-fat diet + streptozotocin (STZ)-induced type 2 diabetic mice. The results showed that different magnetic field intensities and blank control did not affect the blood glucose of normal mice. After starch and glucose administration, different magnetic fields could improve the glucose tolerance of normal mice, and this was obvious in the 600 mT group. In the experiment of type 1 diabetic mice induced by alloxan, the results showed that different magnetic field intensities could improve the starch tolerance of mice, and that in the 400 mT group was obvious. In the experiment of type 2 diabetic mice induced by a high-fat diet + STZ, the 400 mT group could reduce food intake and water consumption in the later period. The 600 mT group could improve the starch tolerance of mice. The 400 and 600 mT groups could reduce fasting blood glucose. At the same time, total cholesterol and triglyceride decreased in different magnetic field intensities, and the 600 mT group could significantly increase the serum insulin content of mice. In summary, the results of this study suggest that SMF has a protective role in diabetic mice. Bioelectromagnetics. © 2020 Bioelectromagnetics Society  相似文献   

12.
We established three types of thrombosis models to explore the effects of the static magnetic field (SMF) on thrombosis in rats and mice with three different MF intensities. In the carrageenan-induced thrombosis model in rats, the SMF treatments reduced the black tail length of rats, extracorporeal thrombus, and the mass of wet and dry thrombus, and improved the coagulation index value. In FeCl3-induced arterial thrombosis model in rats, the SMF treatment showed some anti-thrombotic effects. More specifically, the SMF treatment affected rodent blood pressure, plasma plasminogen activator inhibitor, tissue-type plasminogen activator, thrombus mass, and thrombus protein content. In the adrenaline-induced thrombosis model in mice, the SMF treatment had certain effects on the diameter and blood flow velocity of mouse auricle microcirculation in fine veins and arteries. Overall, the highest MF intensities we tested, 20–150 mT, showed a trend of anti-thrombotic effect, indicating that the moderate-intensity SMF might serve as a potential treatment for clot-related diseases in the future. Bioelectromagnetics. 2020;41:52–62 © 2019 Bioelectromagnetics Society.  相似文献   

13.
The aim of the present work has been the design and the realization of a Magnetostatic Field System for Exposure of Cell cultures (MaFiSEC) for the uniform and the reproducible exposure of cell cultures to static magnetic fields (SMFs) of moderate magnetic induction. Experimental and computer-simulated physical measurements show that MaFiSEC: i) generates a SMF with magnetic induction that can be chosen in the range of 3 to 20 mT; ii) allows the uniform SMF exposure of cells growing in adhesion and in suspension; iii) is cheap and easy to use. The efficacy and reproducibility of MaFiSEC has been tested by comparing the biological effects exerted on isolated human lymphocytes by 72 h of exposure to a magnet (i.e. Neodymium Magnetic Disk, NMD) placed under the culture Petri dish. Lymphocytes morphology, viability, cell death, oxidative stress and lysosomes activity were the parameters chosen to evaluate the SMF biological effects. The continuous exposure of cells to a uniform SMF, achieved with MaFiSEC, allows highly reproducible biochemical and morphological data.  相似文献   

14.
Experimental evidence for the appearance of synchronized bioelectric activity in neurons under applied extremely low frequency (ELF) magnetic fields is shown. We have studied the synchronizing process by recording the intracellular bioelectric activity from pairs of neurons randomly chosen from the brain ganglia of the snail Helix aspersa. The recordings were made in real time under exposure to sinusoidal low frequency (50 Hz) weak (B0=1–15 mT) magnetic fields. Synchronization was observed in 27% of the pairs tested. A linear dependence of the firing frequency f with the energy density of the applied magnetic field (i.e., fB02) was presented. The ability of low frequency sinusoidal weak magnetic fields to promote “magnetic synchronization” is exciting and opens new avenues for induced electromagnetic field bioeffects.  相似文献   

15.
The effects of a static magnetic field (SMF) on the proliferation of various types of human cells were determined. All cultures were maintained at 37 °C throughout the experiment. SMF was generated by placing two magnets oppositely oriented on either side of a T25 flask. The flux density in the flask ranged from 35 to 120 mT. Growth curves were constructed by plotting cell number at 18 h and 4, 7, 11, and 14 days after seeding, with the 18‐h point being a measure of attachment efficiency. Exposure to SMF significantly decreased initial attachment of fibroblasts and decreased subsequent growth compared to sham‐exposed control. Significant effects were observed in both fetal lung (WI‐38) and adult skin fibroblasts, but they were generally larger in the fetal lung fibroblast line. SMF did not affect attachment of human melanoma cells, but inhibited their growth by 20% on day 7. SMF produced no effects in a human adult stem cell line. Oxidant production increased 37% in WI‐38 cells exposed to SMF (230–250 mT) during the first 18 h after seeding, when cell attachment occurs. Conversely, no elevation in oxidant levels was observed after a prolonged 5‐day exposure. These results indicate that exposure to SMF has significant biological effects in some, but not all types of human cells. Bioelectromagnetics 32:140–147, 2011. © 2010 Wiley‐Liss, Inc.  相似文献   

16.
Previously, we found that whole body exposure to static magnetic fields (SMF) at 10 mT (B(max)) and 25 mT (B(max)) for 2-9 weeks suppressed and delayed blood pressure (BP) elevation in young, stroke resistant, spontaneously hypertensive rats (SHR). In this study, we investigated the interrelated antipressor effects of lower field strengths and nitric oxide (NO) metabolites (NO(x) = NO(2)(-) + NO(3)(-)) in SHR. Seven-week-old male rats were exposed to two different ranges of SMF intensity, 0.3-1.0 mT or 1.5-5.0 mT, for 12 weeks. Three experimental groups of 20 animals each were examined: (1) no exposure with intraperitoneal (ip) saline injection (sham-exposed control); (2) 1 mT SMF exposure with ip saline injection (1 mT); (3) 5 mT SMF exposure with ip saline injection (5 mT). Arterial BP, heart rate (HR), skin blood flow (SBF), plasma NO metabolites (NO(x)), and plasma catecholamine levels were monitored. SMF at 5 mT, but not 1 mT, significantly suppressed and retarded the early stage development of hypertension for several weeks, compared with the age matched, unexposed (sham exposed) control. Exposure to 5 mT resulted in reduced plasma NO(x) concentrations together with lower levels of angiotensin II and aldosterone in SHR. These results suggest that SMF may suppress and delay BP elevation via the NO pathways and hormonal regulatory systems.  相似文献   

17.
Summary The influence of a life-long exposure to static magnetic fields (SMF) on the lifespan of female AKR mice which develop spontaneous lymphoblastic leukaemia was investigated. Exposure all day long to a circular SMF, 4.6 mT maximal intensity or 2 h a day, 5 consecutive days a week to a uniform SMF of 400 mT did not modify the lifespan of mice. Exposure 2 h a day, 5 consecutive days a week to a uniform SMF of 600 or 800 mT modified the lifespan: about 50% of the population had a longer survival than the controls. Mice exposed 30 min a day 5 consecutive days a week to a non-uniform SMF presented the same trend.  相似文献   

18.
We designed this study to examine the effects of static magnetic fields (SMF; 120 mT [B(max)] and a maximum spatial magnetic flux gradient of 21 mT/mm) on inhibited tubular formation when treated with human transforming growth factor (TGF)-beta1 at a relatively high concentration (5 ng/ml). Three experimental groups of 25 samples each were examined: (1) sham exposure alone (control); (2) sham-exposure with TGF-beta1; (3) SMF exposure with TGF-beta1. The SMF or sham exposure was carried out for 10 days. Photomicrographs of tubular cells, immunostained with an anti-platelet-endothelial cell adhesion molecule-1 (PECAM-1 [CD31]) antibody as a pan-endothelial marker, were analyzed after the 10-day culture. SMF was found to significantly reverse the inhibition of TGF-beta1 on tubular formation in terms of the area density and length of tubules (arteriogenesis) in the peripheral part of the wells, compared with the TGF-beta1 treatment alone. These findings suggest that one of the possible exogenous factors for arteriogenesis might involve 'magnetic force' (the product of the magnetic flux density, the magnetic gradient, and the volume susceptibility of the cells) because values are much larger in the peripheral part than in the central part.  相似文献   

19.
The subthreshold magnetic modulation technique stimulates cells with mT extremely low-frequency magnetic fields (ELF-MFs), which are insufficient to induce neuronal action potentials. Although they cannot directly induce resting neurons to discharge, mT magnetic stimulation can regulate the excitability of the nervous system, which regulates learning and memory by some unknown mechanisms. Herein, we describe the regulation of mT ELF-MFs with different parameters on synaptic plasticity in hippocampal neurons. Additionally, we summarize the latest research on the possible mechanism of the effect of ELF-MFs on synaptic plasticity. Some studies have shown that ELF-MFs are able to inhibit long-term potentiation (LTP) by increasing concentration of intracellular Ca2+ concentration ([Ca2+]i), as well as concentration of reactive oxygen species. The research in this paper has significance for the comprehensive understanding of relevant neurological mechanisms of learning and memory by mT ELF-MFs stimulation. However, more high-quality research is necessary to determine the regulatory mechanism of mT ELF-MFs on synaptic plasticity in order to optimize this technique as a treatment for neurological diseases. © 2023 Bioelectromagnetics Society.  相似文献   

20.
We investigated the interrelated antihypotensive effects of static magnetic fields (SMF) and plasma catecholamine levels in reserpine-induced hypotensive Wistar-Kyoto rats. Seven-week-old male rats were exposed to two different ranges of SMF intensities, 3.0-10 mT (Bmax) or 7.5-25 mT (Bmax) for 12 weeks. Six experimental groups of 10 animals each were examined: (1) no exposure with intraperitoneal (ip) saline injection (sham exposed control); (2) 10 mT SMF exposure with ip saline injection (10 mT); (3) 25 mT SMF exposure with ip saline injection (25 mT); (4) no exposure with ip reserpine injection (RES); (5) 10 mT SMF exposure with ip reserpine injection (10 mT + RES); (6) 25 mT SMF exposure with ip reserpine injection (25 mT + RES). Reserpine (5 mg/kg) was administered three times a week for 12 weeks, and 18 h after each injection, arterial blood pressure (BP), heart rate, skin blood flow, plasma nitric oxide metabolites, plasma catecholamine levels, and behavioral parameters of a functional observational battery (FOB) were monitored. The action of reserpine significantly decreased BP, reduced plasma norepinephrine (NE), increased the FOB hunched posture score and decreased the number of rearing events in the RES group, compared with the respective age-matched control group. Exposure to 25 mT, but not 10 mT, for 2-12 weeks significantly prevented the reserpine-induced decrease of BP in the 25 mT + RES group compared with the respective RES group. Moreover, exposure to 25 mT for 5 weeks partially suppressed the reserpine-induced NE reduction, but did not bring about a complete reversal of reserpine effects. NE levels for the 25 mT + RES group for 5 weeks were significantly higher compared with the RES group, but still lower compared with the control group. In addition, the FOB hunched posture score for the 25 mT + RES group was significantly lower and the number of rearing events was higher compared with the RES group, but these behavioral parameters did not revert to control levels. There were no significant differences in any of the physiological or behavioral parameters measured between the 10 mT + RES and RES groups, nor between the two different SMF groups and the control group. These results indicate that 25 mT SMF with spatial gradients significantly suppressed the reserpine-induced hypotension and bradykinesia. The antihypotensive effects of SMF on the reserpine-treated group might be at least partially related to the inhibition of NE depletion.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号