首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
20 (R,S)-Ginsenoside-Rg2, an anti-shock agent, is prescribed as a racemate. To analyze simultaneously the enantiomers of 20 (R)-ginsenoside-Rg2 and 20 (S)-ginsenoside-Rg2 in plasma, a simple and reproducible high-performance liquid chromatographic (HPLC) method has been developed. The enantiomeric separation and determination were successfully achieved using a Diamonsil ODS C18 reversed-phase column (5 microm, 250 mm x 4.6 mm) with an RP18 (5 microm) guard column and a mobile phase of MeOH-aq. 4% H3PO4 (65:35, v/v, pH 5.1) with UV detection at 203 nm. Both enantiomers, 20 (R)-ginsenoside-Rg2 and 20 (S)-ginsenoside-Rg2, were well separated at 14.5 min and 13.6 min, respectively. The linear ranges of the standard curves were 2.0-250 microg/ml. The intra- and inter-day precision (R.S.D.) were 相似文献   

2.
A selective chiral high performance liquid chromatographic (HPLC) method was developed and validated to separate and quantify the enantiomers of a novel anticonvulsant agent, N-(4-chlorophenyl)-1-(4-pyridyl)ethylamine (AAP-Cl), in rat plasma. After extraction of the plasma samples with ethyl acetate, the separation was accomplished by an HPLC system consisting of a Chirex chiral column (250 mm x 4.6 mm i.d.) and a mobile phase of hexane:ethanol:tetrahydrofuran (280:20:40 (v/v)) containing trifluroacetic acid (0.3% (v/v)) and triethylamine (0.018% (v/v)) at a flow rate of 0.8 ml/min with UV detection. Male Sprague-Dawley rats were given (+)-AAP-Cl (10 and 20 mg/kg), (-)-AAP-Cl (10 mg/kg) or the racemic mixture (20 mg/kg) by i.v. bolus injection and serial blood samples were collected at different times after drug administration. (+)-AAP-Cl and (-)-AAP-Cl were separated with a resolution factor, Rs, of at least 1.4, and a separation factor, alpha, greater than 1.09. Linear calibration curves were obtained over the concentration range of 0.5-30 microg/ml in plasma for both (+)-AAP-Cl and (-)-AAP-Cl (R2 > or = 0.996) with a limit of quantitation of 100 ng/ml and the recovery was greater than 80% for both enantiomers. The accuracy and precision for both enantiomers ranged from 96 to 102% (+/-0.2-7%) at upper and lower concentrations. The plasma concentration-time profiles of the enantiomers of AAP-Cl were best described by a two-compartment open model with a mean terminal half-life of about 5h, volume of distribution at steady state of 3 l/kg and clearance of about 0.6l/(hkg) in rats. There was no significant difference between the pharmacokinetic parameters of (+)-AAP-Cl and (-)-AAP-Cl, suggesting that the disposition of AAP-Cl in rats is not enantioselective. In addition, no chiral inversion of (+)-AAP-Cl to (-)-AAP-Cl or vice versa was observed. The results of this investigation have shed some light on the mechanism of action and disposition of AAP-Cl in rats.  相似文献   

3.
A sensitive and selective analytical method for the enantioselective determination of MK-0767, a dual peroxisome proliferator-activated receptor (PPAR) alpha/gamma agonist, in human plasma has been developed and validated. The chromatography is based on normal-phase chiral separation on a Kromasil, 5 microm, CHI-DMB 250 mm x 4.6 mm column. The detection involves the direct introduction of the normal phase eluent into MS/MS without the addition of a post-column reagent. Atmospheric pressure chemical ionization (APcI) mode was selected as the ion source in this method. With proper sample handling and processing procedures, ex vivo interconversion of the enantiomers was kept to minimum during sample collection, preparation and short term storage of frozen human plasma samples. The method was successfully utilized to determine the concentrations of MK-0767 enantiomers in human plasma to support pharmacokinetic investigation in man.  相似文献   

4.
An enantioselective HPLC method has been developed and validated for the stereospecific analysis of N-ethyl-3,4-methylenedioxyamphetamine (MDE) and its major metabolites N-ethyl-4-hydroxy-3-methoxyamphetamine (HME) and 3,4-methylenedioxyamphetamine (MDA). These compounds have been analyzed both from human plasma and urine after administration of 70 mg pure MDE-hydrochloride enantiomers to four subjects. The samples were prepared by hydrolysis of the o-glucuronate and sulfate conjugates using beta-glucuronidase/arylsulfatase and solid-phase extraction with a cation-exchange phase. A chiral stationary protein phase (chiral-CBH) was used for the stereoselective determination of MDE, HME and MDA in a single HPLC run using sodium dihydrogenphosphate, ethylendiaminetetraacetic acid disodium salt and isopropanol as the mobile phase (pH 6.44) and fluorimetric detection (lambda(ex) 286 nm, lambda(em) 322 nm). Moreover, a suitable internal standard (N-ethyl-3,4-methylenedioxybenzylamine) was synthesized and qualified for quantitation purposes. The method showed high recovery rates (>95%) and limits of quantitation for MDE and MDA of 5 ng/ml and for HME of 10 ng/ml. The RSDs for all working ranges of MDE, MDA and HME in plasma and urine, respectively, were less than 1.5%. After validation of the analytical methods in plasma and urine samples pharmacokinetic parameters were calculated. The plasma concentrations of (R)-MDE exceeded those of the S-enantiomer (ratio R:S of the area under the curve, 3.1) and the plasma half time of (R)-MDE was longer than that of (S)-MDE (7.9 vs. 4.0 h). In contrast, the stereochemical disposition of the MDE metabolites HME and MDA was reversed. Concentrations of the (S)-metabolites in plasma of volunteers were much higher than those of the (R)-enantiomers.  相似文献   

5.
A liquid chromatographic column-switching method for the enantioselective determination of (RS)-sotalol in plasma was developed and validated. The method is based on the on-line coupling of a precolumn filled with the restricted access material LiChrospher ADS to a cellobiohydrolase I-based chiral stationary phase (CSP). The plasma samples were injected onto the precolumn using a mobile phase containing 1% methanol in 10 mM phosphate buffer at pH 7.4 for 10 min for the removal of matrix components. The analytes were transferred to the CSP for their enantiomeric separation by backflushing the precolumn with 15% 2-propanol in 10 mM phosphate buffer (pH 7.0) including 0.05 mM EDTA. The quantitative determination of the sotalol enantiomers was possible upon addition of the internal standard (S)-atenolol. The method was validated showing a good linearity in the concentration range from 25 to 1000 microg l(-1) for each enantiomer. The average values of the intra- and inter-day variability were 1.17% and 3.42%, respectively, for (R)-sotalol and 1.24% and 1.99%, respectively, for (S)-sotalol. The applicability of the method to real world samples has been proven by means of two pharmacokinetic studies. They revealed that the pharmacokinetic properties of the sotalol enantiomers do not differ significantly neither for healthy young volunteers after single dose application nor for elder patients in the steady state.  相似文献   

6.
A sensitive and specific liquid chromatography electrospray ionization-tandem mass spectrometry method for the enantioselective determination of the novel beta-adrenolytic compound, 1-(1-H-indol-4-yloxy)-3-{[2-(2-methoxyphenoxy)ethylo]amino} propan-2-ol, in rat plasma has been developed and validated. Chromatography was performed on a reversed-phase Chiralcel OD-RH analytical column (150x4.6 mm, 5 microm, Daicel Chemical Industries, Tokyo, Japan) with isocratic elution using a mobile phase containing acetonitrile and water with 0.01% formic acid. Detection was achieved by an Applied Biosystems MDS Sciex (Concord, Ontario, Canada) API 2000 triple quadrupole mass spectrometer. Electrospray ionization (ESI) was used for ion production. The limit of detection in the MRM mode was found to be 1.25 ng/ml. The limit of quantification of both enantiomers was 2.5 ng/ml. The precision and accuracy for both intra- and inter-day determination of 2F109 enantiomers ranged from 2.6 to 12% and from 89.1 to 107.1%. This analytical method allowed us to carry out pharmacokinetic studies in rats. Our findings demonstrate that 2F109 shows stereoselective disposition in rat plasma after i.v. administration. The terminal half-lives of (+)-(R)-2F109 and (-)-(S)-2F109 were 33.5 and 42.6 min, respectively. The AUC0-inf of (+)-(R)-2F109 exceeded that of (-)-(S)-2F109.  相似文献   

7.
M Enquist  J Hermansson 《Chirality》1989,1(3):209-215
A method for the determination of (R)- and (S)-atenolol in human plasma and urine is described. The enantiomers of atenolol are extracted into dichloromethane containing 3% heptafluorobutanol followed by acetylation with acetic anhydride at 60 degrees C for 2 h. The acetylated enantiomers were separated on a chiral alpha 1-AGP column. Quantitation was performed using fluorescence detection. A phosphate buffer pH 7.1 (0.01 M phosphate) containing 0.25% (v/v) acetonitrile was used as mobile phase. The described procedure allows the detection of less than 6 ng of each enantiomer in 1 ml plasma. The relative standard deviation is 4.4% at 30 ng/ml of each enantiomer in plasma. The plasma concentration of (R)- and (S)-atenolol did not differ significantly in two subjects who received a single tablet of racemic atenolol. The R/S ratio of atenolol in urine was approximately 1.  相似文献   

8.
Enantiomeric resolution of teratolol was achieved on a vancomycin macrocyclic antibiotic chiral stationary phase known as Chirobiotic V with UV detection set at 220 nm. The polar ionic mobile phase (PIM) consisted of methanol-glacial acetic acid-triethylamine (100:0.01:0.015, v/v/v) has been used at a flow rate of 0.8 ml min(-1) . The calibration curves in plasma were linear over the range of 5-500 ng ml(-1) for each enantiomer with detection limit of 2 ng ml(-1) . The proposed method was validated in compliance with the international conference on harmonization (ICH) guidelines. The developed method applied for the trace analyses of tertatolol enantiomers in plasma and for the pharmacokinetic study of tertatolol enantiomers in rat plasma. The assay proved to be suitable for therapeutic drug monitoring and chiral quality control for tertatolol formulations by HPLC.  相似文献   

9.
A sensitive and selective high-performance liquid chromatographic (HPLC) method has been developed for the simultaneous determination of bufuralol enantiomers in plasma and pharmaceutical formulations. Enantiomeric resolution was achieved on a vancomycin macrocyclic antibiotic chiral stationary phase (CSP) known as Chirobiotic V with UV detection set at 254 nm. The polar ionic mobile phase (PIM) consisting of methanol-glacial acetic acid-triethylamine (100:0.015:0.010, v/v/v) has been used at a flow rate of 0.5 ml/min. The method is highly specific where other coformulated compounds did not interfere. The stability of bufuralol enantiomers under different degrees of temperature was also studied. The results showed that the drug is stable for at least 7 days at 70 degrees C. The method was validated for its linearity, accuracy, precision and robustness. An experimental design was used during validation to evaluate method robustness. The calibration curves in plasma were linear over the range of 5-500 ng/ml for each enantiomer with detection limit of 2 ng/ml. The mean relative standard deviation (RSD) of the results of within-day precision and accuracy of the drug were 0.05) between inter- and intra-day studies for each enantiomer which confirmed the reproducibility of the assay method. The mean extraction efficiency for S-(-)- and R-(+)-bufuralol from plasma was in the range 97-102% at 15-400 ng/ml level for each enantiomer. The overall recoveries of bufuralol enantiomers from pharmaceutical formulations was in the range 99.6-102.2% with %RSD ranging from 1.06 to 1.16%. The assay method proved to be suitable as chiral quality control for bufuralol formulations by HPLC and for therapeutic drug monitoring.  相似文献   

10.
A stereoselective bioanalytical method for the simultaneous quantification of the enantiomers of verapamil and its active main metabolite norverapamil in human plasma has been developed and validated. The samples were analysed by liquid chromatography-electrospray-tandem mass spectrometry (LC-ESI-MS/MS) in the Selected Reaction Monitoring (SRM) mode using a deuterated internal standard. The stationary phase used for the chiral separation was a Chiral-AGP. The enantiomers of verapamil were selectively detected from those of norverapamil by the mass spectrometer due to different molecular masses, although there was a chromatographic co-elution. Thus, time-consuming procedures like achiral preseparation or chemical derivatisation could be avoided. Higher detection sensitivity than earlier published methods based on fluorescence detection was obtained, although a mobile phase of high water-content and high flow-rate was introduced into the electrospray interface (85% aqueous ammonium acetate pH 7.4 +15% acetonitrile at 0.6 ml/min). The enantiomers of verapamil and norverapamil could be quantified at levels down to 50 pg and 60 pg/500 microl plasma sample, respectively, with R.S.D. in the range of 3.6-7.8%. The presented method was successfully applied to an in vivo intestinal absorption and bioavailability study in humans, using the Loc-I-Gut method.  相似文献   

11.
R-/S-2-(2-hydroxypropanamido)-5-trifluoromethyl benzoic acid (R-/S-HFBA) is a novel COX inhibitor with remarkable anti-inflammatory and antiplatelet aggregation activities, but no gastrointestinal toxicity. In our previous study, the different pharmacokinetic profiles of the two enantiomers in rats were observed after administration of R-HFBA and S-HFBA. Stereoselective protein binding of the two enantiomers may be a reason for the different pharmacokinetic behaviors. In this study, we developed and validated an UPLC-MS/MS method for determining stereoselective binding of HFBA enantiomers to rat, dog, and human plasma in vitro. Chromatographic separation was achieved by gradient elution with a flow rate of 0.4 mL/min. MS/MS detection was operated in positive electrospray using multiple reaction monitoring (MRM) mode. The method was proved to be linear over the concentration range of 0.005 to 10 μg/mL with a lower limit of quantification of 0.005 μg/mL. The developed method was successfully employed to the plasma protein binding study of HFBA enantiomers. Equilibrium dialysis method was applied to assess drug-plasma protein interactions. The results showed that the enantiomers were both extensively bound to three species plasma and protein binding of R-/S-HFBA was concentration dependent. R-HFBA and S-HFBA showed significant species difference among rat, dog, and human plasma and stereoselective plasma protein binding.  相似文献   

12.
An automated online sample extraction method for rat plasma was developed and validated for the quantification of (R)- and (S)-propranolol following the intravenous administration of either the racemate or the individual enantiomers at 5 mg/kg. A dual-column extraction system coupled to a chiral stationary phase (CSP) was used in conjunction with liquid chromatography-tandem mass spectrometry. In this method, two Oasis HLB extraction columns (50x1.0 mm) in parallel were used for online plasma sample purification and teicoplanin CSP (Chirobiotic T) was used for the enantiomeric separation. This method allowed the use of one of the extraction columns for purification while the other was being equilibrated. Hence, the time required for re-conditioning the extraction columns did not contribute to the total analysis time per sample, which resulted in a relatively shorter run time and higher throughput. The lower limit of detection was 0.5 ng/ml and the lower limit of quantification was 2 ng/ml for each enantiomer using 25 microl of rat plasma. The method was validated with a linear calibration curve between 2 and 2000 ng/ml for (R)- and (S)-propranolol, respectively. The intra- and inter-day precision (C.V.) was no more than 7.6% and the accuracy of the assay was between 92 and 103%. The teicoplanin CSP proved to be rugged with excellent reproducibility of chromatographic parameters.  相似文献   

13.
A stereoselective high-performance liquid chromatographic (HPLC) method is described for the selective and sensitive quantitation in human plasma of R-(+)- and S-(−)-enantiomers of remoxipride. Remoxipride was extracted from basified plasma into hexane-methyl-tert.-butyl ether (20:80, v/v), washed with sodium hydroxide (1.0 M), then back-extracted into phosphoric acid (0.1 M). A structural analog of remoxipride was used as an internal standard. The sample extracts were chromatographed using a silica-based derivatized cellulose chiral column, Chiralcel OD-R, and a reversed-phase eluent containing 30–32% acetonitrile in 0.1 M potassium hexafluorophosphate. Ultraviolet (UV) absorbance detection was performed at 214 nm. Using 0.5-ml plasma aliquots, the method was validated in the concentration range 0.02-2.0 μg/ml and was applied in the investigation of systemic inversion of remoxipride enantiomers in man.  相似文献   

14.
A stereospecific method for simultaneous quantitation of the enantiomers of tramadol (T) and its active metabolites O-demethyl tramadol (M1) and O-demethyl-N-demethyl tramadol (M5) in human plasma is reported. After the addition of penbutolol (IS), plasma (0.5 ml) samples were extracted into methyl tert-butyl ether, followed by back extraction into an acidic solution. The separation was achieved using a Chiralpak AD column with a mobile phase of hexanes:ethanol:diethylamine (94:6:0.2) and a flow rate of 1 ml/min. The fluorescence of analytes was then detected at excitation and emission wavelengths of 275 and 300 nm, respectively. All the six enantiomeric peaks of interest plus three unknown metabolite peaks and IS peak (a total of 10 peaks) eluted within 23 min, free from endogenous interference. The assay was validated in the plasma concentration range of 2.5-250 ng/ml, with a lower limit of quantitation of 2.5 ng/ml, for all the six analytes. The extraction efficiency (n=5) was close to 100% for both T and M1 enantiomers and 85% for M5 and IS enantiomers. The application of the assay was demonstrated by simultaneous measurement of plasma concentrations of T, M1, and M5 enantiomers in a healthy volunteer after the administration of 50 mg oral doses of racemic T.  相似文献   

15.
Qiu J  Wang Q  Zhu W  Jia G  Wang X  Zhou Z 《Chirality》2007,19(1):51-55
A chiral high-performance liquid chromatography method with diode array detector was developed and validated for stereoselective determination of benalaxyl (BX) in rabbit plasma. Good separation was achieved at 20 degrees C using cellulose tris-(3,5-dimethylphenylcarbamate) as chiral stationary phase, a mixture of n-hexane and 2-propanol (97:3) as mobile phase at a flow rate of 1.0 ml/min. The assay method was linear over a range of concentrations (0.25-25 microg/ml) in plasma and the mean recovery was greater than 90% for both enantiomers. The limits of quantification and detection for both enantiomers in plasma were 0.25 and 0.1 microg/ml, respectively. Intra- and interday relative standard deviations (RSDs) did not exceed 10% for three-tested concentrations. The method was successfully applied to pharmacokinetic studies of BX enantiomers in rabbits. The result suggested that the pharmacokinetics of BX enantiomers was stereoselective in rabbits.  相似文献   

16.
A method has been developed for the determination of total celiprolol (sum of enantiomers) or the enantiomers (R)-celiprolol and (S)-celiprolol in plasma by high-performance liquid chromatography with UV and fluorescence detection. After extraction from alkalinized plasma with methyl-tert-butyl ether and back-extraction into 0.01 M HCl (for total celiprolol determination) or after evaporation of the organic phase and derivatisation with R(−)-1-(1-naphthyl)ethyl isocyanate (enantiomer determination), total celiprolol or its diastereomeric derivatives were chromatographed on a reversed-phase HPLC column with a mixture of acetonitrile and phosphate buffer pH 3.5 (+0.05% triethylamine). Acebutolol was used as internal standard. Linearity was obtained in the range of 5 to 2000 ng/ml for total and 2.5 to 500 ng/ml for enantiomer determination. Intra-day and inter-day variation was lower than 10%. The method can be applied for analysis of plasma samples obtained from patients treated with oral racemic celiprolol doses.  相似文献   

17.
An assay comprising two simple, selective and isocratic HPLC methods with UV detection was developed and validated for measuring warfarin enantiomers and all five warfarin monohydroxylated metabolites in patient blood plasma. Following liquid/liquid extraction from 1 ml of blood plasma a baseline separation of analytes was achieved on chiral (alpha(1) acid glycoprotein - AGP) and achiral (C(18)) column. Both methods were consistent (R.S.D.<6.9% for warfarin enantiomers and<8.9% for monohydroxylated metabolites) and linear (r>0.998). The limits of detection were 25 ng/ml for warfarin enantiomers, 25 ng/ml for 4'-, 10-, 6- and 7-hydroxywarfarin, 35 ng/ml for 8-hydroxywarfarin and 50 ng/ml for racemic warfarin. In a clinical study in 204 patients, it was confirmed that the assay is appropriate for evaluation of influences of genetic polymorphisms, demographic factors and concomitant drug treatment on warfarin metabolism.  相似文献   

18.
A high-performance liquid chromatographic method was developed to quantitate the plasma concentrations of the individual enantiomers of a candidate 8-aminoquinoline antimalarial agent WR 238,605 (I). The method employed one-step liquid extraction of a 0.5-ml plasma sample followed by direct injection of the extract through a chiral column and detection by fluorescence. Quantification was achieved using an internal standard. The limit of quantification was 10 ng/ml for each enantiomer. The method is sufficiently sensitive to quantitate the plasma concentrations of both enantiomers for 30 days following a single oral dose of 400 mg of the antimalarial agent administered as the racemic succinate salt to healthy human male volunteers. In nearly all samples taken 12 h to 30 days post-dose from three subjects, the difference in the plasma concentrations of the two enantiomers is less than 10%.  相似文献   

19.
The title compounds, 1a and 1b, have been synthesized in a three-step sequence starting from (-)-(S) and (+)-(R)-propylene oxide, respectively, in acceptable overall yields. The enantiomeric excess values for 1a and 1b were 96% and 93% respectively, as assessed by HPLC analysis on a chiral stationary phase of the corresponding N-acetyl derivatives. The synthetic route herein presented may represent a facile entry to highly enriched mexiletine enantiomers, alternative to those previously reported in the literature.  相似文献   

20.
Racemic 5-hydroxy-2-(dipropylamino)tetralin (5-OH DPAT), a potent and selective dopamine (DA) D2-receptor agonist, was resolved into the enantiomers by a new method. The enantiomers of 5-OH DPAT were determined by chiral ion-pair chromatography using N-benzyloxycarbonylglycyl-L-proline as the counter ion. The enantiomeric purity of (R)-5-OH DPAT was found to be greater than 99.7%. The ability of the enantiomers to change the rat brain DOPA levels was evaluated in vivo. The results indicate that (R)-5-OH DPAT is a weakly potent DA D2-receptor antagonist.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号