首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 156 毫秒
1.
Bacteriological analyses were performed on the effluent from a conventional water treatment pilot plant in which granular activated carbon (GAC) had been used as the final process to assess the impact of GAC on the microbial quality of the water produced. Samples were collected twice weekly for 160 days from the effluents of six GAC columns, each of which used one of four different empty-bed contact times (7.5, 15, 30, and 60 min). The samples were analyzed for heterotrophic plate counts and total coliforms. Effluent samples were also exposed to chloramines and free chlorine for 60 min (pH 8.2, 23 degrees C). Bacterial identifications were performed on the disinfected and nondisinfected effluents. Additional studies were conducted to assess the bacteriological activity associated with released GAC particles. The results indicated that heterotrophic plate counts in the effluents from all columns increased to 10(5) CFU/ml within 5 days and subsequently stabilized at 10(4) CFU/ml. The heterotrophic plate counts did not differ at different empty-bed contact times. Coliforms (identified as Enterobacter spp.) were recovered from the nondisinfected effluent on only two occasions. The disinfection results indicated that 1.5 mg of chloramines per liter inactivated approximately 50% more bacteria than did 1.0 mg of free chlorine per liter after 1 h of contact time. Chloramines and chlorine selected for the development of different bacterial species--Pseudomonas spp. and Flavobacterium spp., respectively.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

2.
The microbial dynamics associated with granular activated carbon (GAC) in a pilot water treatment plant were investigated over a period of 16 months. Microbial populations were monitored in the influent and effluent waters and on the GAC particles by means of total plate counts and ATP assays. Microbial populations between the influent and effluent waters of the GAC columns generally increased, indicating microbial growth. The dominant genera of microorganisms isolated from interstitial waters and GAC particles were Achromobacter, Acinetobacter, Aeromonas, Alcaligenes, Bacillus, Chromobacterium, Corynebacterium, Micrococcus, Microcyclus, Paracoccus, and Pseudomonas. Coliform bacteria were found in small numbers in the effluents from some of the GAC columns in the later months of the study. Oxidation of influent waters with ozone and maintenance of aerobic conditions on the GAC columns failed to appreciably enhance the microbial growth on GAC.  相似文献   

3.
The microbial dynamics associated with granular activated carbon (GAC) in a pilot water treatment plant were investigated over a period of 16 months. Microbial populations were monitored in the influent and effluent waters and on the GAC particles by means of total plate counts and ATP assays. Microbial populations between the influent and effluent waters of the GAC columns generally increased, indicating microbial growth. The dominant genera of microorganisms isolated from interstitial waters and GAC particles were Achromobacter, Acinetobacter, Aeromonas, Alcaligenes, Bacillus, Chromobacterium, Corynebacterium, Micrococcus, Microcyclus, Paracoccus, and Pseudomonas. Coliform bacteria were found in small numbers in the effluents from some of the GAC columns in the later months of the study. Oxidation of influent waters with ozone and maintenance of aerobic conditions on the GAC columns failed to appreciably enhance the microbial growth on GAC.  相似文献   

4.
Nitrification in chloraminated drinking water can have a number of adverse effects on water quality, including a loss of total chlorine and ammonia-N and an increase in the concentration of heterotrophic plate count bacteria and nitrite. To understand how nitrification develops, a study was conducted to examine the factors that influence the occurrence of ammonia-oxidizing bacteria (AOB) in a chloraminated distribution system. Samples were collected over an 18-month period from a raw-water source, a conventional treatment plant effluent, and two covered, finished-water reservoirs that previously experienced nitrification episodes. Sediment and biofilm samples were collected from the interior wall surfaces of two finished-water pipelines and one of the covered reservoirs. The AOB were enumerated by a most-probable-number technique, and isolates were isolated and identified. The resistance of naturally occurring AOB to chloramines and free chlorine was also examined. The results of the monitoring program indicated that the levels of AOB, identified as members of the genus Nitrosomonas, were seasonally dependent in both source and finished waters, with the highest levels observed in the warm summer months. The concentrations of AOB in the two reservoirs, both of which have floating covers made of synthetic rubber (Hypalon; E.I. du Pont de Nemours & Co., Inc., Wilmington, Del.), had most probable numbers that ranged from less than 0.2 to greater than 300/ml and correlated significantly with temperature and levels of heterotrophic plate count bacteria. No AOB were detected in the chloraminated reservoirs when the water temperature was below 16 to 18 degrees C. The study indicated that nitrifiers occur throughout the chloraminated distribution system. Higher concentrations of AOB were found in the reservoir and pipe sediment materials than in the pipe biofilm samples. The AOB were approximately 13 times more resistant to monochloramine than to free chlorine. After 33 min of exposure to 1.0 mg of monochloramine per liter (pH 8.2, 23 degrees C), 99% of an AOB culture was inactivated. The amounts of this disinfectant that are currently used (1.5 mg/liter at a 3:1 ratio of chlorine to ammonia-N) may be inadequate to control the growth of these organisms in the distribution system.  相似文献   

5.
Forty eyewash units were sampled for protozoa, bacteria, and fungi. Total heterotrophic bacterial counts on nutrient agar and R2A agar (Difco Laboratories, Detroit, Mich.) ranged from 0 to 10(5) CFU/ml, with Pseudomonas spp. being the most frequently isolated. Total counts of 10(4) and 10(8) cells per ml were obtained with the acridine orange staining procedure. All samples were examined for Legionella spp. by direct fluorescent-antibody staining and by culturing on buffered charcoal-yeast extract agar containing alpha-ketoglutarate and glycine and supplemented with cycloheximide, vancomycin, and polymyxin B. DNA-DNA hybridization was used to confirm identification of the Legionella isolates. Legionellae were detected in 35 of 40 (87.5%) samples by direct fluorescent-antibody staining, with 3 samples yielding both Legionella spp. and amoebae. Amoebae identified as Hartmannella, Vahlkampfia, Acanthamoeba, and Cochliopodium spp. were detected in 19 of 40 (47:5%) samples. Sabouraud dextrose agar was used to obtain a crude estimate of viable fungal populations, pH, hardness, and ammonia, alkalinity, chlorine, copper, and iron contents were recorded for all water samples collected from eyewash stations; 33% of the samples had greater than or equal to 10 mg of CO2 per liter. It is concluded that eyewash stations not regularly flushed and/or cleaned and used to flush traumatized eye tissue may be a source of infection and can contaminate laboratory environments via aerosol transmission.  相似文献   

6.
Three enteric pathogens Yersinia enterocolitica O:8, Salmonella typhimurium, and enterotoxigenic Escherichia coli, were examined for their ability to colonize granular activated carbon (GAC) in pure cultures and in the presence of autochthonous river water organisms. All three organisms readily colonized sterile GAC and maintained populations of ca. 10(5) to 10(7) CFU g-1 for 14 days when suspended in sterile river water. Exposure of pathogen biofilms on GAC to unsterile river water resulted in a gradual decline in pathogens on the carbon (0.08 to 0.14 log day-1). When pathogens were introduced to sterile GAC in the presence of heterotrophic plate count organisms, they attached at levels similar to those in the pure cultures and then decreased (0.10 to 0.22 log day-1). When added with heterotrophic plate count bacteria to GAC supporting a mature biofilm of native river water bacteria, they attached at a lower level (1.0 X 10(4) to 4.6 X 10(4) CFU g-1) and decreased at a more rapid rate (0.11 to 0.70 log day-1).  相似文献   

7.
An experimental procedure was developed to study the association of selected bacteria and macroinvertebrates and their response to free available chlorine disinfection. The organisms selected for study were Escherichia coli ( LacZ545 ), Enterobacter cloacae (ATCC 23355), and the amphipod Hyalella azteca . E. coli was shown to bind tightly (1.6 X 10(4) CFU per amphipod ) to this macroinvertebrate and to resist repeated attempts to wash it off. E. cloacae was shown to bind much less tightly (1.4 X 10(3) CFU per amphipod ) to H. azteca and was less resistant to removal by washing. The extent of association is a function of macroinvertebrate size (surface area), but the procedure produces repeatable results usable for controlled experimentation. This method, together with the dual bacterial identification criteria (morphology and antibiotic resistance), was used to study the response of unassociated and associated E. coli and E. cloacae to disinfection with free available chlorine at 1.0 mg/liter. Unassociated E. coli populations decreased to less than 1% of their zero time controls within 1 min of contact time, whereas more than 2% of the associated E. coli populations remained viable after 60 min of contact at 1.0 mg of free available chlorine per liter. Unassociated E. cloacae populations decreased to less than 1% of their zero time controls within 1 min of contact time, whereas ca. 15% of the associated E. cloacae populations remained viable after 60 min of contact at 1.0 mg of free available chlorine per liter.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

8.
An experimental procedure was developed to study the association of selected bacteria and macroinvertebrates and their response to free available chlorine disinfection. The organisms selected for study were Escherichia coli ( LacZ545 ), Enterobacter cloacae (ATCC 23355), and the amphipod Hyalella azteca . E. coli was shown to bind tightly (1.6 X 10(4) CFU per amphipod ) to this macroinvertebrate and to resist repeated attempts to wash it off. E. cloacae was shown to bind much less tightly (1.4 X 10(3) CFU per amphipod ) to H. azteca and was less resistant to removal by washing. The extent of association is a function of macroinvertebrate size (surface area), but the procedure produces repeatable results usable for controlled experimentation. This method, together with the dual bacterial identification criteria (morphology and antibiotic resistance), was used to study the response of unassociated and associated E. coli and E. cloacae to disinfection with free available chlorine at 1.0 mg/liter. Unassociated E. coli populations decreased to less than 1% of their zero time controls within 1 min of contact time, whereas more than 2% of the associated E. coli populations remained viable after 60 min of contact at 1.0 mg of free available chlorine per liter. Unassociated E. cloacae populations decreased to less than 1% of their zero time controls within 1 min of contact time, whereas ca. 15% of the associated E. cloacae populations remained viable after 60 min of contact at 1.0 mg of free available chlorine per liter.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

9.
The occurrence of Aeromonas spp. and hygienic indicator organisms in raw and treated waters of five drinking water production plants in Flanders (Belgium) was surveyed over a period of 17 months. Aeromonads were isolated on ampicillin-dextrin agar (ADA) and further identified by gas-liquid chromatographic analysis of their cellular fatty acid methyl ester (FAME) content. ADA medium was found to be highly specific for the enumeration of Aeromonas spp. In general, Aeromonas counts were very low in untreated groundwater but numbered 104–106 colony-forming units per liter in open storage reservoirs for surface water. Aeromonas spp. were seasonally distributed with maximal densities occurring during the summer. The ecology of Aeromonas in the different waters was studied in relation to the physical, chemical, and microbiological water characteristics. Strongly positive correlations were observed between Aeromonas densities and heterotrophic plate counts, whereas a clearly negative relationship was found with dissolved oxygen. On average, 99.7% of the aeromonads were removed by flocculation-decantation followed by breakpoint chlorination, whereas 98.9% were removed by slow sand filtration. Flocculation-decantation without breakpoint chlorination did not reduce the microbial numbers. At three of four drinking water production plants tested, rapid sand filtration decreased the number of aeromonads and hygienic indicator organisms. At one plant, however, the numbers of Aeromonas and hygienic indicator organisms were high in the sand filter effluents. Increased numbers of aeromonads were also counted in the effluent of the activated carbon filters. Hence, inactivation of Aeromonas spp. by the current process technology appears not sufficient to exclude postchlorination. The survival of aeromonads in certain filter systems may be due to the growth of these bacteria on biodegradable organic material, provided by the decomposition from bacteria, algae, or other sources. Correspondence to: W. Verstraete  相似文献   

10.
Reclaimed water is an important resource for areas with inadequate water supplies. However, there have been few studies on the variety of microorganisms found in this type of water, since typically reclaimed water is examined only for the presence of coliform bacteria. Many microorganisms, including the legionellae, are known to be more resistant to chlorine than are coliform bacteria. Previously, we detected > 10(3) Legionella cells per ml in primary and secondary sewage effluents and observed no significant reduction in population numbers throughout the treatment process. In this study, we detected Legionella spp. in chlorinated effluent by using an EnviroAmp Legionella PCR kit and direct fluorescent antibody (DFA) staining. However, we were not able to isolate Legionella spp. from either natural or seeded reclaimed water samples. This suggests that the Legionella spp. detected by the PCR and DFA methods may be injured or viable but nonculturable after exposure to the high residual chlorine levels typically found in this type of water source. The numbers of coliform bacteria were low (< 2 cells per 100 ml) in most reclaimed water samples and were not correlated with the presence or absence of Legionella spp. We also collected air samples from above a secondary aeration basin and analyzed them by using the PCR, DFA, and plate culture methods. Legionella spp. were detected in the air obtained from above the secondary basin with all three methods. We concluded that the PCR was superior to the culture and DFA methods for detecting Legionella spp. in environmental water samples.  相似文献   

11.
Granular activated carbon (GAC) beds may be used for removal of dissolved organic matter during the treatment of drinking water. However, they might also change the microbiological quality of the water entering the distribution system either by changing the predominant bacteria or the bacterial density of the treated water. A 3-year pilot plant study of water treatment using GAC beds was conducted at the Baxter Water Treatment Plant in Philadelphia. During the study, bacteria were isolated from the raw water and from the effluents of the GAC treatment units. At the end of the study, bacteria were also isolated from the GAC units and from sand beds operated in parallel with the GAC units. Bacterial genera in the GAC effluents and in the GAC units themselves were similar to those found in the raw water and in the sand beds. Prechlorination and (or) preozonation of the water before GAC treatment had no noticeable effect on the bacterial genera found as compared with GAC unit having no predisinfection. The bacterial genera found in this study were similar to those found in seven other studies of GAC water treatment that used a variety of treatment schemes and a variety of heterotrophic plate count techniques to evaluate bacterial populations. From these several studies it appears that GAC treatment does not change the nature of the bacterial populations associated with drinking water.  相似文献   

12.
A survey of 100 swimming pools has been conducted to assess the effectiveness of disinfection practices against various microorganisms and to check compliance with recommended chlorine levels and pH. Microbiological quality was assessed from densities of total coliforms, Escherichia coli, and Pseudomonas aeruginosa, total colony counts, and the presence or absence of amoebae, including the pathogen Naegleria fowleri. Although a free chlorine residual of 1.0 mg/liter and a pH range of 7.0 to 7.6 are recommended by local health authorities, 41 pools had a lower free chlorine residual and 37 had a pH outside this range. Multiple logistic regression analysis was used to test the association of field measurements with the microbiological data. The analysis demonstrated a strong positive association of free chlorine with bacteriological quality and the absence of Naegleria spp. No other field measurement was predictive in this regard, although the absence of all amoebae was associated with a relatively low water temperature and pH. Using a mathematical model derived from this analysis, it was estimated that 99% of pools would have acceptable bacteriological quality and 94% would be free of Naegleria spp. at a free chlorine residual of 1.0 mg/liter. However, at the mean water temperature (23 degrees C) and pH (7.5) seen in this study, other amoebae would still be detectable in 500-ml samples taken from 40% of pools at this chlorine level.  相似文献   

13.
A survey of 100 swimming pools has been conducted to assess the effectiveness of disinfection practices against various microorganisms and to check compliance with recommended chlorine levels and pH. Microbiological quality was assessed from densities of total coliforms, Escherichia coli, and Pseudomonas aeruginosa, total colony counts, and the presence or absence of amoebae, including the pathogen Naegleria fowleri. Although a free chlorine residual of 1.0 mg/liter and a pH range of 7.0 to 7.6 are recommended by local health authorities, 41 pools had a lower free chlorine residual and 37 had a pH outside this range. Multiple logistic regression analysis was used to test the association of field measurements with the microbiological data. The analysis demonstrated a strong positive association of free chlorine with bacteriological quality and the absence of Naegleria spp. No other field measurement was predictive in this regard, although the absence of all amoebae was associated with a relatively low water temperature and pH. Using a mathematical model derived from this analysis, it was estimated that 99% of pools would have acceptable bacteriological quality and 94% would be free of Naegleria spp. at a free chlorine residual of 1.0 mg/liter. However, at the mean water temperature (23 degrees C) and pH (7.5) seen in this study, other amoebae would still be detectable in 500-ml samples taken from 40% of pools at this chlorine level.  相似文献   

14.
AIMS: To investigate the retention and removal of the fish pathogenic bacterium Yersinia ruckeri in biological sand filters and effects on the microbial community composition. METHODS AND RESULTS: Sand filter columns were loaded (70 mm day(-1)) with fish farm wastewater and a suspension (10(8) CFU ml(-1)) of Y. ruckeri. Bacterial numbers and protozoan numbers were determined by plate counts and epifluorescence microscopy, respectively, and microbial biomass and community composition were assessed by phospholipid fatty acids (PLFA) analysis. Concentrations of Y. ruckeri in the filter effluent decreased from 10(8) to 10(3)-10(5) CFU ml(-1) during the experiment. Numbers of Y. ruckeri in the sand decreased from 10(6) CFU g(-1) dry weight (DW) sand to 10(4) CFU g(-1) DW sand. In contrast, microbial biomass determined with plate counts and total PLFA increased during the whole experiment. Principal component analysis (PCA) revealed a change in microbial community composition with time, with the most pronounced change in surface layers and towards the end of the experiment. Protozoan numbers increased from ca 0-600 cells g(-1) DW sand, indicating the establishment of a moderate population of bacterial grazers. CONCLUSIONS: The removal of Y. ruckeri improved during the experiment. Introduction of Y. ruckeri to the sand filter columns stimulated growth of other micro-organisms, which in turn caused a shift in the microbial community composition in the sand. SIGNIFICANCE AND IMPACT OF THE STUDY: This study increases the understanding of the dynamics of sand filters subjected to a high loading of a pathogenic bacterium and can therefore be used in future work were the overall aim is to provide a more reliable and efficient removal of pathogenic bacteria in biological sand filter systems.  相似文献   

15.
Persistence of Bacillus atrophaeus subsp. globigii spores on corroded iron coupons in drinking water was studied using a biofilm annular reactor. Spores were inoculated at 10(6) CFU/ml in the dechlorinated reactor bulk water. The dechlorination allowed for observation of the effects of hydraulic shear and biofilm sloughing on persistence. Approximately 50% of the spores initially adhered to the corroded iron surface were not detected after 1 month. Addition of a stable 10 mg/liter free chlorine residual after 1 month led to a 2-log(10) reduction of adhered B. atrophaeus subsp. globigii, but levels on the coupons quickly stabilized thereafter. Increasing the free chlorine concentration to 25 or 70 mg/liter had no additional effect on inactivation. B. atrophaeus subsp. globigii spores injected in the presence of a typical distribution system chlorine residual (approximately 0.75 mg/liter) resulted in a steady reduction of adhered B. atrophaeus subsp. globigii over 1 month, but levels on the coupons eventually stabilized. Adding elevated chlorine levels (10, 25, and 70 mg/liter) after 1 month had no effect on the rate of inactivation. Decontamination with elevated free chlorine levels immediately after spore injection resulted in a 3-log(10) reduction within 2 weeks, but the rate of inactivation leveled off afterward. This indicates that free chlorine did not reach portions of the corroded iron surface where B. atrophaeus subsp. globigii spores had adhered. B. atrophaeus subsp. globigii spores are capable of persisting for an extended time in the presence of high levels of free chlorine.  相似文献   

16.
PEROXONE is an advanced oxidation process generated by combining ozone and hydrogen peroxide. This process stimulates the production of hydroxyl radicals, which have been shown to be superior to ozone for the destruction of some organic contaminants. In this study, pilot-scale experiments were conducted to evaluate the microbicidal effectiveness of PEROXONE and ozone against three model indicator groups. Escherichia coli and MS2 coliphage were seeded into the influent to the preozonation contactors of a pilot plant simulating conventional water treatment and were exposed to four ozone dosages (0.5, 1.0, 2.0, and 4.0 mg/liter), four hydrogen peroxide/ozone (H2O2/O3) weight ratios (0, 0.3, 0.5, and 0.8), and four contact times (4, 5, 12, and 16 min) in two source waters--Colorado River water and state project water--of different quality. The removal of heterotrophic plate count bacteria was also monitored. Results of the study indicated that the microbicidal activity of PEROXONE was greatly affected by the applied ozone dose, H2O2/O3 ratio, contact time, source water quality, and type of microorganism tested. At contact times of 5 min or less, ozone alone was a more potent bactericide than PEROXONE at all H2O2/O3 ratios tested. However, this decrease in the bactericidal potency of PEROXONE was dramatic only as the H2O2/O3 ratio was increased from 0.5 to 0.8. The fact that the bactericidal activity of PEROXONE generally decreased with increasing H2O2/O3 ratios was thought to be related to the lower ozone residuals produced. The viricidal activity of PEROXONE and ozone was comparable at all of the H2O2/O3 ratios. Heterotrophic plate count bacteria were the most resistant group of organisms. Greater inactivation of E. coli and MS2 was observed in Colorado River water than in state project water and appeared to result from differences in the turbidity and alkalinity of the two waters. Regardless of source water, greater than 4.5 log10 of E. coli and MS2 was inactivated at an applied ozone dosage of 2.0 mg/liter (and a 4-min contact time) when the H2O2/O3 ratio was less than or equal to 0.5. Comparative disinfection experiments indicated that free chlorine was the most potent bactericidal agent, followed (in descending order of effectiveness) by ozone, PEROXONE, and chloramines. These results indicate that the PEROXONE process must be optimized for each source water to achieve microbicidal effectiveness.  相似文献   

17.
PEROXONE is an advanced oxidation process generated by combining ozone and hydrogen peroxide. This process stimulates the production of hydroxyl radicals, which have been shown to be superior to ozone for the destruction of some organic contaminants. In this study, pilot-scale experiments were conducted to evaluate the microbicidal effectiveness of PEROXONE and ozone against three model indicator groups. Escherichia coli and MS2 coliphage were seeded into the influent to the preozonation contactors of a pilot plant simulating conventional water treatment and were exposed to four ozone dosages (0.5, 1.0, 2.0, and 4.0 mg/liter), four hydrogen peroxide/ozone (H2O2/O3) weight ratios (0, 0.3, 0.5, and 0.8), and four contact times (4, 5, 12, and 16 min) in two source waters--Colorado River water and state project water--of different quality. The removal of heterotrophic plate count bacteria was also monitored. Results of the study indicated that the microbicidal activity of PEROXONE was greatly affected by the applied ozone dose, H2O2/O3 ratio, contact time, source water quality, and type of microorganism tested. At contact times of 5 min or less, ozone alone was a more potent bactericide than PEROXONE at all H2O2/O3 ratios tested. However, this decrease in the bactericidal potency of PEROXONE was dramatic only as the H2O2/O3 ratio was increased from 0.5 to 0.8. The fact that the bactericidal activity of PEROXONE generally decreased with increasing H2O2/O3 ratios was thought to be related to the lower ozone residuals produced. The viricidal activity of PEROXONE and ozone was comparable at all of the H2O2/O3 ratios. Heterotrophic plate count bacteria were the most resistant group of organisms. Greater inactivation of E. coli and MS2 was observed in Colorado River water than in state project water and appeared to result from differences in the turbidity and alkalinity of the two waters. Regardless of source water, greater than 4.5 log10 of E. coli and MS2 was inactivated at an applied ozone dosage of 2.0 mg/liter (and a 4-min contact time) when the H2O2/O3 ratio was less than or equal to 0.5. Comparative disinfection experiments indicated that free chlorine was the most potent bactericidal agent, followed (in descending order of effectiveness) by ozone, PEROXONE, and chloramines. These results indicate that the PEROXONE process must be optimized for each source water to achieve microbicidal effectiveness.  相似文献   

18.
Our survey of cooling tower water demonstrated that the highest density of legionellae, ≥104 CFU/100 ml, appeared in water containing protozoa, ≥102 MPN/100 ml, and heterotrophic bacteria, ≥106 CFU/100 ml, at water temperatures between 25 and 35°C. Viable counts of legionellae were detected even in the winter samples, and propagation, up to 105 CFU/100 ml, occurs in summer. The counts of legionellae correlated positively with increases in water temperature, pH, and protozoan counts, but not with heterotrophic bacterial counts. The water temperature of cooling towers may promote increases in the viable counts of legionellae, and certain microbes, e.g., protozoa or some heterotrophic bacteria, may be a factor stimulating the propagation of legionellae.  相似文献   

19.
A mercury-resistant bacterial strain which is able to reduce ionic mercury to metallic mercury was used to remediate in laboratory columns mercury-containing wastewater produced during electrolytic production of chlorine. Factory effluents from several chloralkali plants in Europe were analyzed, and these effluents contained total mercury concentrations between 1.6 and 7.6 mg/liter and high chloride concentrations (up to 25 g/liter) and had pH values which were either acidic (pH 2.4) or alkaline (pH 13.0). A mercury-resistant bacterial strain, Pseudomonas putida Spi3, was isolated from polluted river sediments. Biofilms of P. putida Spi3 were grown on porous carrier material in laboratory column bioreactors. The bioreactors were continuously fed with sterile synthetic model wastewater or nonsterile, neutralized, aerated chloralkali wastewater. We found that sodium chloride concentrations up to 24 g/liter did not inhibit microbial mercury retention and that mercury concentrations up to 7 mg/liter could be treated with the bacterial biofilm with no loss of activity. When wastewater samples from three different chloralkali plants in Europe were used, levels of mercury retention efficiency between 90 and 98% were obtained. Thus, microbial mercury removal is a potential biological treatment for chloralkali electrolysis wastewater.  相似文献   

20.
Disinfection of bacteria attached to granular activated carbon.   总被引:19,自引:13,他引:6       下载免费PDF全文
Heterotrophic plate count bacteria, coliform organisms, and pathogenic microorganisms attached to granular activated carbon particles were examined for their susceptibility to chlorine disinfection. When these bacteria were grown on carbon particles and then disinfected with 2.0 mg of chlorine per liter (1.4 to 1.6 mg of free chlorine residual per liter after 1 h) for 1 h, no significant decrease in viable counts was observed. Washed cells attached to the surface of granular activated carbon particles showed similar resistance to chlorine, but a progressive increase in sublethal injury was found. Observations made by scanning electron microscope indicated that granular activated carbon was colonized by bacteria which grow in cracks and crevices and are coated by an extracellular slime layer. These data suggest a possible mechanism by which treatment and disinfection barriers can be penetrated and pathogenic bacteria may enter drinking water supplies.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号