首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A label-free and sensitive faradic impedance spectroscopy (FIS) aptasensor based on target-induced aptamer displacement was developed for the determination of lysozyme as a model system. The aptasensor was fabricated by self-assembling the partial complementary single strand DNA (pcDNA)–lysozyme binding aptamer (LBA) duplex on the surface of a gold electrode. To measure lysozyme, the change in interfacial electron transfer resistance of the aptasensor using a redox couple of [Fe(CN)6]3−/4− as the probe was monitored. The introduction of target lysozyme induced the displacement of the LBA from the pcDNA–LBA duplex on the electrode into the solution, decreasing the electron transfer resistance of the aptasensor. The decrease in the FIS signal is linear with the concentration of lysozyme in the range from 0.2 nM to 4.0 nM, with a detection limit of 0.07 nM. The fabricated aptasensor shows a high sensitivity, good selectivity and satisfactory regeneration. This work demonstrates that a high sensitivity of the fabricated aptasensor can be obtained using a relatively short pcDNA. This work also demonstrates that the target-induced aptamer displacement strategy is promising in the design of an electrochemical aptasensor for the determination of lysozyme with good selectivity and high sensitivity.  相似文献   

2.
We report a novel micro-potentiometric hemoglobin (Hb) immunosensor based on electrochemically synthesized polypyrrole (PPy)–gold nanoparticles (AuNPs) composite. PPy–AuNPs film with AuNPs uniformly distributed in it was deposited on gold electrode surface by a simple and direct procedure, without the addition of any nanoparticles or reducing agent. And this generic method makes it possible to deposite different polymers on miniaturized electrodes. With the existence of AuNPs, the antibody immobilization onto the electrode surface was facilitated. Morphology study by field emission scanning electron microscope (FE-SEM) confirms the presence of AuNPs in PPy. Based on an ion-sensitive field-effect transistors (ISFETs) integrated chip, a micro-potentiometric immunosensor for Hb and hemoglobin-A1c (HbA1c) has been constructed. The sensor response was linear over the concentration range 60–180 μg/ml Hb and 4–18 μg/ml HbA1c. The Hb concentration in whole blood samples has also been analysed, with a linear dose–response behavior between 125 and 197 μg/ml and a sensitivity of 0.20 mV μg−1 ml. The measuring ranges of the developed Hb and HbA1c immunosensors meet the clinical demand for measuring the HbA1c/Hb ratio of 5–20%. This sensor results in simple and rapid differential measurement of Hb and HbA1c, and has great potential to become an inexpensive and portable device for monitoring of diabetes.  相似文献   

3.
In the work, a label-free electrochemiluminescence (ECL) aptasensor for the sensitive and selective detection of thrombin was constructed based on target-induced direct ECL signal change by virtue of a novel assembly strategy of oligonucleotide and luminol functionalized gold nanoparticles (luminol-AuNPs). It is the first label-free ECL biosensor based on luminol and its analogs functionalized AuNPs. Streptavidin AuNPs coated with biotinylated DNA capture probe 1 (AuNPs-probe 1) were firstly assembled onto an gold electrode through 1,3-propanedithiol. Then luminol-AuNPs co-loaded with thiolated DNA capture probe 2 and thiolated thrombin binding aptamer (TBA) (luminol-AuNPs-probe 2/TBA) were assembled onto AuNPs-probe 1 modified electrode through the hybridization between capture probes 1 and 2. The luminol-AuNPs-probe 2/TBA acted as both molecule recognition probe and sensing interface. An Au/AuNPs/ds-DNA/luminol-AuNPs/TBA multilayer architecture was obtained. In the presence of target thrombin, TBA on the luminol-AuNPs could capture the thrombin onto the electrode surface, which produced a barrier for electro-transfer and influenced the electro-oxidation reaction of luminol, leading to a decrease in ECL intensity. The change of ECL intensity indirectly reflected the concentration of thrombin. Thus, the approach showed a high sensitivity and a wider linearity for the detection of thrombin in the range of 0.005-50nM with a detection limit of 1.7pM. This work reveals that luminol-AuNPs are ideal platform for label-free ECL bioassays.  相似文献   

4.
Zhao J  Zhang Y  Li H  Wen Y  Fan X  Lin F  Tan L  Yao S 《Biosensors & bioelectronics》2011,26(5):2297-2303
Successful development of an ultrasensitive and highly specific electrochemical aptasensor for thrombin based on amplification of aptamer-gold nanoparticles-horseradish peroxidase (aptamer-AuNPs-HRP) conjugates was reported. In this electrochemical protocol, aptamer1 (Apt1) was immobilized on core/shell Fe(3)O(4)/Au magnetic nanoparticles (AuMNPs) and served as capture probe. Aptamer2 (Apt2) was dual labeled with AuNPs and HRP and used as detection probe. In the presence of thrombin, the sandwich format of AuMNPs-Apt1/thrombin/Apt2-AuNPs-HRP was fabricated. Remarkable signal amplification was realized by taking the advantage of AuNPs and catalytic reactions of HRP. Other proteins, such as human serum albumin, lysozyme, fibrinogen, and IgG did not show significant interference with the assay for thrombin. Linear response to thrombin concentration in the range of 0.1-60 pM and lower detection limit down to 30 fM (S/N=3) was obtained with the proposed method. This electrochemical aptasensor is simple, rapid (the whole detection period for a thrombin sample is less than 35 min), sensitive and highly specific, it shows promising potential in protein detection and disease diagnosis.  相似文献   

5.
A novel non-enzymatic electrochemiluminescence (ECL) sensor based on palladium nanoparticles (PdNPs)–functional carbon nanotubes (FCNTs) was discovered for glucose detection. PdNPs were homogeneously modified on FCNTs using a facile spontaneous redox reaction method. Their morphologies were characterized by transmission electron microscopy (TEM). Based on ECL experimental results, the PdNPs–FCNTs–Nafion film modified electrode displayed high electrocatalytic activity towards the oxidation of glucose. The free radicals generated by the glucose oxidation reacted with the luminol anion (LH), and enhanced the ECL signal. Under the optimized conditions, the linear response of ECL intensity to glucose concentration was valid in the range from 0.5 to 40 μmol L−1 (r2 = 0.9974) with a detection limit (S/N = 3) of 0.09 μmol L−1. In addition, the modified electrode presented high resistance towards the poisoning of chloride ion, high selectivity and long-term stability. In order to verify the sensor reliability, it was applied to the determination of glucose in glucose injection samples. The results indicated that the proposed approach provided a highly sensitive, more facile method with good reproducibility for glucose determination, promising the development of a non-enzymatic ECL glucose sensor.  相似文献   

6.
We report here for the first time on the fabrication of highly dispersed PtM (M = Ru, Pd and Au) nanoparticles on composite film of multi-walled carbon nanotubes (MWNTs)–ionic liquid (IL, i.e., trihexyltetradecylphosphonium bis(trifluoromethylsulfonyl)imide) by using ultrasonic-electrodeposition method. The PtM nanoparticles are characterized by scanning electron microscopy, X-ray photoelectron spectroscopy and X-ray diffraction, and we find that they are well-dispersed and exhibit alloy properties. Electrochemical experiments show that the PtRu(1:1, i.e., ratio of c(H2PtCl6)/c(RuCl3))–MWNT–IL nanocomposite modified glassy carbon electrode (PtRu(1:1)–MWNT–IL/GCE) has smaller electron transfer resistance and larger active surface area than PtRu(1:1)/GCE, PtRu(1:1)–MWNT/GCE, PtPd(1:1)–MWNT–IL/GCE and PtAu(1:1)–MWNT–IL/GCE. The PtRu(1:1)–MWNT–IL/GCE also presents stronger electrocatalytic activity toward the glucose oxidation than other electrodes. At −0.1 V, the electrode responds linearly to glucose up to 15 mM in neutral media, with a detection limit of 0.05 mM (S/N = 3) and detection sensitivity of 10.7 μA cm−2 mM−1. Meanwhile, the interference of ascorbic acid, uric acid, acetamidophenol and fructose is effectively avoided. The as-made sensor was applied to the determination of glucose in serum and urine samples. The results agreed closely with the results obtained by a hospital. This novel nonenzyme sensor thus has potential application in glucose detection.  相似文献   

7.
An ultrasensitive and highly specific electrochemical aptasensor for detection of thrombin based on gold nanoparticles and thiocyanuric acid is presented. For this proposed aptasensor, aptamerI was immobilized on the magnetic nanoparticles, aptamerII was labeled with gold nanoparticles. The magnetic nanoparticle was used for separation and collection, and gold nanoparticle offered excellent electrochemical signal transduction. Through the specific recognition for thrombin, a sandwich format of magnetic nanoparticle/thrombin/gold nanoparticle was fabricated, and the signal amplification was further implemented by forming network-like thiocyanuric acid/gold nanoparticles. A significant sensitivity enhancement had been obtained, and the detection limit was down to 7.82 aM. The presence of other proteins such as BSA and lysozyme did not affect the detection of thrombin, which indicates a high specificity of thrombin detection could be achieved. This electrochemical aptasensor is expected to have wide applications in protein monitoring and disease diagnosis.  相似文献   

8.
A sensitive chronocoulometric aptasensor for the detection of thrombin has been developed based on gold nanoparticle amplification. The functional gold nanoparticles, loaded with link DNA (LDNA) and report DNA (RDNA), were immobilized on an electrode by thrombin aptamers performing as a recognition element and capture probe. LDNA was complementary to the thrombin aptamers and RDNA was noncomplementary, but could combine with [Ru(NH3)6]3+ (RuHex) cations. Electrochemical signals obtained by RuHex that bound quantitatively to the negatively charged phosphate backbone of DNA via electrostatic interactions were measured by chronocoulometry. In the presence of thrombin, the combination of thrombin and thrombin aptamers and the release of the functional gold nanoparticles could induce a significant decrease in chronocoulometric signal. The incorporation of gold nanoparticles in the chronocoulometric aptasensor significantly enhanced the sensitivity. The performance of the aptasensor was further increased by the optimization of the surface density of aptamers. Under optimum conditions, the chronocoulometric aptasensor exhibited a wide linear response range of 0.1–18.5 nM with a detection limit of 30 pM. The results demonstrated that this nanoparticle-based amplification strategy offers a simple and effective approach to detect thrombin.  相似文献   

9.
In this work, colloidal laponite nanoparticles were further expanded into the design of the third-generation biosensor. Direct electrochemistry of the complex molybdoenzyme xanthine oxidase (XnOx) immobilized on glassy carbon electrode (GCE) by laponite nanoparticles was investigated for the first time. XnOx/laponite thin film modified electrode showed only one pair of well defined and reversible cyclic voltammetric peaks attributed to XnOx–FAD cofactor at about −0.370 V vs. SCE (pH 5). The formal potential of XnOx–FAD/FADH2 couple varied linearly with the increase of pH in the range of 4.0–8.0 with a slope of −54.3 mV pH−1, which indicated that two-proton transfer was accompanied with two-electron transfer in the electrochemical reaction. More interestingly, the immobilized XnOx retained its biological activity well and displayed an excellent electrocatalytic performance to both the oxidation of xanthine and the reduction of nitrate. The electrocatalytic response showed a linear dependence on the xanthine concentration ranging from 3.9 × 10−8 to 2.1 × 10−5 M with a detection limit of 1.0 × 10−8 M based on S/N = 3.  相似文献   

10.
A novel direct readout colorimetric optical glucose sensor strip was constructed based on a three-layer film, including a green-emitted CdTe/CdS quantum dots (QDs) layer as a stable color background, a red-fluorescent platinum-porphyrin oxygen-sensing layer and a glucose oxidase layer. The sensor achieved high resolution (up to 0.2 mmol L−1) glucose determination with a detection range from 0 to 3.0 mmol L−1. A “glucose ruler” which acts as a glucose standard colorimetric card was obtained. Glucose concentration could easily be directly readout using the “glucose ruler”, which made the glucose determination rapid, convenient and easy. The effects of pH, salinity and temperature were systematically investigated. The prepared sensor was finally applied for glucose sample analysis, compared with the “glucose ruler”, accurate results could be directly readout.  相似文献   

11.
A convenient and effective strategy for fabrication of hydrogen peroxide biosensor based on sodium alginate (SA) and polyvinyl butyral (PVB) as matrices was reported in this paper. The horseradish peroxidase (HRP) and SA were electro-co-deposited onto the surface of gold electrode, and the HRP–SA/Au electrode was further coated with PVB. The interaction between HRP and SA was characterized by UV–vis absorption spectroscopy, and the fabricating process of biosensor was characterized by electrochemical impedance spectroscopy (EIS). The electrochemical characteristics of the biosensor were studied by cyclic voltammetry and chronoamperometry. Experimental conditions were investigated which influence the performance of the biosensor, such as pH, and applied potential. The biosensor showed a linear response to H2O2 over a concentration range from 7.0 × 10−6 to 4.1 × 10−3 M with a detection limit of 1.8 × 10−6 M based on a signal-to-noise ratio of 3 under optimum conditions. The value of HRP in the composite was evaluated to be 1.38 mM. The biosensor obtained from this study possesses high sensitivity, good reproducibility, and long-term stability.  相似文献   

12.
An amperometric assay for the determination of inorganic phosphate (Pi) in urine has been developed without the need for sample preparation. A screen-printed carbon electrode modified with the electrocatalyst cobalt phthalocyanine (CoPC–SPCE) and covered with a cellulose acetate membrane (CAM) serves as the sensor. The sensor detects hydrogen peroxide (H2O2), which is produced as a result of the oxidative decarboxylation of pyruvate, catalyzed by pyruvate oxidase (PyOd), in the presence of Pi, oxygen, and cofactors. Following optimization of solution conditions, and in the presence of a urine sample, a linear range was found to exist between the rate of current increase and phosphate concentration over the range of 2.27 × 10−5 to 1.81 × 10−4 M, and the limit of detection was found to be 4.27 × 10−6 M. The assay was applied to the determination of phosphate ions in the urine of a normal subject, and the mean concentration in unspiked urine was found to be 3.40 × 10−5 M with a coefficient of variation of 8.0% (n = 5). The mean recovery of phosphate added to urine samples was 98.7% with a coefficient of variation of 5.5% (n = 3). To the authors’ knowledge, this is the first report of an amperometric assay for Pi that incorporates a CoPC–SPCE as the sensing device.  相似文献   

13.
This paper proposes an aptasensor for progesterone (P4) detection in human serum and urine based on the aggregating behavior of gold nanoparticles (AuNPs) controlled by the interactions among P4-binding aptamer, target P4 and cationic surfactant hexadecyltrimethylammonium bromide (CTAB). The aptamer can form an aptamer-P4 complex with P4, leaving CTAB free to aggregate AuNPs in this aptasensor. Thus, the sensing solution will turn from red (520 nm) to blue (650 nm) in the presence of P4 because P4 aptamers are used up firstly owing to the formation of an aptamer-P4 complex, leaving CTAB free to aggregate AuNPs. However, in the absence of P4, CTAB combines with aptamers so that AuNPs still remain dispersed. Therefore, this assay makes it possible to detect P4 not only by absorbance measurement but also through naked eyes. By monitoring the variation of absorbance and color, a CTAB-induced colorimetric assay for P4 detection was established with a detection limit of 0.89 nM. Besides, the absorbance ratio A650/A520 has a linear correlation with the P4 concentration of 0.89–500 nM. Due to the excellent recoveries in serum and urine, this biosensor has great potential with respect to the visual and instrumental detection of P4 in biological fluids.  相似文献   

14.
This work reports a novel signal amplification strategy based on three-dimensional ordered macroporous C60-poly(3,4-ethylenedioxythiophene)-1-butyl-3-methylimidazolium hexafluorophosphate (3DOM C60-PEDOT-[BMIm][BF6]) for ultrasensitive detection of thrombin by cascade catalysis of Au-PEDOT@SiO2 microspheres and alcohol dehydrogenase (ADH). Au-PEDOT@SiO2 microspheres were constructed not only as nanocarriers to anchor the large amounts of secondary thrombin aptamers but also as nanocatalysts to catalyze the oxidation of ethanol efficiently. Significantly, the electrochemical signal was greatly enhanced based on cascade catalysis: First, ADH catalyzed the oxidation of ethanol to acetaldehyde with the concomitant generation of NADH in the presence of β-nicotinamide adenine dinucleotide hydrate (NAD+). Then, gold nanoparticles (AuNPs) as nanocatalysts could effectively catalyze NADH to produce NAD+ with the help of PEDOT as redox probe. Under the optimal conditions, the proposed aptasensor exhibits a linear range of 2 × 10−13 to 2 × 10−8 M with a low detection limit of 2 × 10−14 M for thrombin detection and shows high sensitivity and good specificity.  相似文献   

15.
A highly sensitive electrochemical DNA biosensor made of polyaniline (PANI) and gold nanoparticles (AuNPs) nanocomposite (AuNPs@PANI) has been used for the detection of trace concentration of Ag+. In the presence of Ag+, with the interaction of cytosine–Ag+–cytosine (C–Ag+–C), cytosine-rich DNA sequence immobilized onto the surface of AuNPs@PANI has a self-hybridization and then forms a duplex-like structure. The whole detection procedure of Ag+ based on the developed biosensor was evaluated by electrochemical impedance spectroscopy. On semi-logarithmic plots of the log Ag+ concentration versus peak current, the results show that the prepared biosensor can detect silver ions at a wide linear range of 0.01–100 nM (R = 0.9828) with a detection limit of 10 pM (signal/noise = 3). Moreover, the fabricated sensor exhibits good selectivity and repeatability. The detection of Ag+ was determined by Ag+ self-induced conformational change of DNA scaffold that involved only one oligonucleotide, showing its convenience and availability.  相似文献   

16.
Edge plane pyrolytic graphite electrode (EPPGE) modified with single-wall carbon nanotubes (SWNTs) has been used as a sensor to determine triamcinolone, abused by athletes for doping. A comparison of the voltammetric behavior between SWNTs modified EPPGE and fullerene – C60-modified EPPGE indicated that SWNTs modified EPPGE is more sensitive. The electrode exhibited an effective catalytic response with good reproducibility and stability. The effect of several parameters such as pH, square wave frequency and steroid concentration were studied. The square wave voltammetric response of the electrode to triamcinolone is linear in the range 0.1–25 nM with a detection limit and sensitivity of 8.9 × 10−10 M and 2.06 μA nM−1, respectively. The method was applied for the determination of triamcinolone in several commercially available pharmaceuticals and real urine samples obtained from patients undergoing pharmacological treatment with triamcinolone. A comparison of the observed results with HPLC analysis indicated a good agreement. The product obtained after reduction of triamcinolone was also characterized using 1H NMR and GC–MS and the site of reduction is found to be carbonyl group at position 20. The method described is rapid, simple and accurate and can be easily applied for detecting cases of doping.  相似文献   

17.
Three microalgal species (Dictyosphaerium chlorelloides (D.c.), Scenedesmus intermedius (S.i.) and Scenedesmus sp. (S.s.)) were encapsulated in silicate sol–gel matrices and the increase in the amount of chlorophyll fluorescence signal was used to quantify simazine. Influence of several parameters on the preparation of the sensing layers has been evaluated: effect of pH on sol–gel gelation time; effect of algae density on sensor response; influence of glycerol (%) on the membrane stability. Long term stability was also tested and the fluorescence signal from biosensors remained stable for at least 3 weeks. D.c. biosensor presented the lowest detection limits for simazine (3.6 μg L−1) and the broadest dynamic calibration range (19–860 μg L−1) with IC50 125 ± 14 μg L−1. Biosensor was validated by HPLC with UV/DAD detection. The biosensor showed response to those herbicides that inhibit the photosynthesis at photosystem II (triazines: simazine, atrazine, propazine, terbuthylazine; urea based herbicides: linuron). However, no significant increases of fluorescence response was obtained for similar concentrations of 2,4-D (hormonal herbicide) or Cu(II). The combined use of two biosensors that use two different genotypes, sensitive and resistant to simazine, jointly allowed improving microalgae biosensor specificity.  相似文献   

18.
Here, we report a sensitive amplified electrochemical impedimetric aptasensor for thrombin, a kind of serine protease that plays important role in thrombosis and haemostasis. For improving detection sensitivity, a sandwich sensing platform is fabricated, in which the thiolated aptamers are firstly immobilized on a gold substrate to capture the thrombin molecules, and then the aptamer functionalized Au nanoparticles (AuNPs) are used to amplify the impedimetric signals. Such designed aptamer/thrombin/AuNPs sensing system could not only improve the detection sensitivity compared to the reported impedimetric aptasensors but also provide a promising signal amplified model for aptamer-based protein detection. In this paper, we realize a sensitive detection limit of 0.02 nM, with a linear range of 0.05-18 nM. Meanwhile, the effect of 6-mercaptohexanol (MCH) and 2-mercaptoethanol (MCE) on the modification of the electrode is investigated.  相似文献   

19.
In sodium acetate–acetic acid buffer solution, Au, Ag, Pt, Pd, Fe3O4, and Cu2O nanoparticles have catalytic enhancement effect on the reduction of Cu2+ by ascorbic acid to form large copper particles that exhibit a strong resonance scattering peak at 610 nm. Those nanocatalytic reactions were studied by the resonance scattering spectral technique, and smaller nanogold exhibited stronger catalytic enhancement effect in pH 4.2 sodium acetate–acetic acid buffer solution. The resonance scattering intensity at 610 nm increased linearly with the concentrations of 0.02 to 1.60, 0.040 to 1.20, and 0.12 to 4.70 nM nanogold in sizes of 5, 10, and 15 nm with detection limits of 0.010, 0.030, and 0.10 nM, respectively. An immunonanogold-catalytic resonance scattering bioassay was established, combining the immunonanogold-catalytic effect on CuSO4–ascorbic acid reaction with the resonance scattering detection technique. As a model, 0.03 to 7.5 ng ml−1 immunoglobulin G can be assayed by this immunonanogold-catalytic resonance scattering bioassay with a detection limit of 0.015 ng ml−1.  相似文献   

20.
High strength milk permeate derived from ultra-filtration based cheese making process was treated in an anaerobic moving bed biofilm reactor (AMBBR) under mesophilic (35 °C) condition. Total chemical oxygen demand (TCOD) removal efficiencies of 86.3–73.2% were achieved at organic loading rates (OLR) of 2.0–20.0 g TCOD L−1 d−1. A mass balance model gave values of methane yield coefficient (YG/S) and cell maintenance coefficient (km) of 0.341 L CH4 g−1 TCODremoved and 0.1808 g TCODremoved g−1 VSS d−1, respectively. The maximum substrate utilization rate Umax was determined as 89.3 g TCOD L−1 d−1 by a modified Stover–Kincannon model. Volumetric methane production rates (VMPR) were shown to correlate with the biodegradable TCOD concentration through a Michaelis–Menten type equation. Moreover, based on VMPR and OLR removed from the reactor, the sludge production yield was determined as 0.0794 g VSS g−1 TCODremoved.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号