1.
The non-invasive character of exhaled breath (EBC) collection makes this fluid attractive for monitoring the respiratory tract by the measurement of various compounds. Because EBC is likely to reflect the composition of the airway-lining fluid, it can provide valuable information on possible disease states. Aim of our study was to apply proteomic technology to the study of EBC samples collected from single patients with pulmonary emphysema associated to alpha(1)-antitrypsin deficiency. The protein profiles from EBC of twenty patients and of twenty-five healthy individuals, used as controls, have been analyzed in parallel by a combination of 1-DE, 2-DE, micro-HPLC and MS. These sensitive techniques allowed to identify a number of cytokines and cytokeratins. Their level was found to be higher in patients than in controls.  相似文献   

2.
Hydrogen peroxide (H2O2) production in exhaled air was measured in ventilated preterm newborns at 5, 24 and 48 hours after delivery, using originally designed method of exhaled breath condensate (EBC) collection. H2O2 production in expired gas was 812+/-34 pmol/20 min during the first measurement and then declined to 389+/-21 at 24 hours and 259+/-26 pmol/20 min at 48 hours.  相似文献   

3.
Abstract

Oxidative stress is the hallmark of various chronic inflammatory lung diseases. Increased concentrations of reactive oxygen species (ROS) in the lungs of such patients are reflected by elevated concentrations of oxidative stress markers in the breath, airways, lung tissue and blood. Traditionally, the measurement of these biomarkers has involved invasive procedures to procure the samples or to examine the affected compartments, to the patient's discomfort. As a consequence, there is a need for less or non-invasive approaches to measure oxidative stress. The collection of exhaled breath condensate (EBC) has recently emerged as a non-invasive sampling method for real-time analysis and evaluation of oxidative stress biomarkers in the lower respiratory tract airways. The biomarkers of oxidative stress such as H2O2, F2-isoprostanes, malondialdehyde, 4-hydroxy-2-nonenal, antioxidants, glutathione and nitrosative stress such as nitrate/nitrite and nitrosated species have been successfully measured in EBC. The reproducibility, sensitivity and specificity of the methodologies used in the measurements of EBC oxidative stress biomarkers are discussed. Oxidative stress biomarkers also have been measured for various antioxidants in disease prognosis. EBC is currently used as a research and diagnostic tool in free radical research, yielding information on redox disturbance and the degree and type of inflammation in the lung. It is expected that EBC can be exploited to detect specific levels of biomarkers and monitor disease severity in response to appropriate prescribed therapy/treatment.  相似文献   

4.
Oxidative stress is the hallmark of various chronic inflammatory lung diseases. Increased concentrations of reactive oxygen species (ROS) in the lungs of such patients are reflected by elevated concentrations of oxidative stress markers in the breath, airways, lung tissue and blood. Traditionally, the measurement of these biomarkers has involved invasive procedures to procure the samples or to examine the affected compartments, to the patient's discomfort. As a consequence, there is a need for less or non-invasive approaches to measure oxidative stress. The collection of exhaled breath condensate (EBC) has recently emerged as a non-invasive sampling method for real-time analysis and evaluation of oxidative stress biomarkers in the lower respiratory tract airways. The biomarkers of oxidative stress such as H2O2, F2-isoprostanes, malondialdehyde, 4-hydroxy-2-nonenal, antioxidants, glutathione and nitrosative stress such as nitrate/nitrite and nitrosated species have been successfully measured in EBC. The reproducibility, sensitivity and specificity of the methodologies used in the measurements of EBC oxidative stress biomarkers are discussed. Oxidative stress biomarkers also have been measured for various antioxidants in disease prognosis. EBC is currently used as a research and diagnostic tool in free radical research, yielding information on redox disturbance and the degree and type of inflammation in the lung. It is expected that EBC can be exploited to detect specific levels of biomarkers and monitor disease severity in response to appropriate prescribed therapy/treatment.  相似文献   

5.
Exercise-caused metabolic changes can be followed by monitoring exhaled volatiles; however it has not been previously reported if a spectrum of exhaled gases is modified after physical challenge. We have hypothesized that changes in volatile molecules assessed by an electronic nose may be the reason for the alkalization of the exhaled breath condensate (EBC) fluid following physical exercise.Ten healthy young subjects performed a 6-minute running test. Exhaled breath samples pre-exercise and post-exercise (0 min, 15 min, 30 min and 60 min) were collected for volatile pattern ("smellprint") determination and pH measurements (at 5.33 kPa CO2), respectively. Exhaled breath smellprints were analyzed using principal component analysis and were related to EBC pH.Smellprints (p=0.04) and EBC pH (p=0.01) were altered during exercise challenge. Compared to pre-exercise values, smellprints and pH differed at 15 min, 30 min and 60 min following exercise (p<0.05), while no difference was found at 0 min post-exercise. In addition, a significant correlation was found between volatile pattern of exhaled breath and EBC pH (p=0.01, r=-0.34).Physical exercise changes the pattern of exhaled volatiles together with an increase in pH of breath. Changes in volatiles may be responsible for increase in EBC pH.  相似文献   

6.
Samples of exhaled breath condensate (EBC) provide a convenient and non-invasive method to study inflammation in lung diseases. The aim of the present study was to evaluate and compare the inflammatory protein mediator levels in EBC from healthy donors (HD) and from patients with exacerbation of chronic obstructive pulmonary disease (COPD) using an EBC collection device with and without a coating of albumin as a carrier. We studied 13 HD and 26 patients with exacerbation of COPD. The concentrations of myeloperoxidase (MPO), IFNγ and secretory leukocyte protease inhibitor (SLPI) in EBC were measured by immunoassays. The EBC samples from HD and COPD patients showed higher concentrations of MPO when samples were recovered with an albumin-coated device. Furthermore, levels of MPO in COPD patients were significantly higher than in HD. An inverse correlation was observed between MPO and spirometric parameters (FVC and FEV1). Almost all samples collected with the albumin-coated device showed higher amounts of IFNγ and SLPI than those collected with the uncoated device. The levels of SLPI in COPD patients were significantly higher than in HD. A direct correlation was observed between FVC% predicted and SLPI. We concluded that coating the collection device with albumin increased the sensitivity of the technique, at least for measurements of MPO, SLPI and IFNγ. Furthermore, the higher levels of MPO and SLPI and lower levels of IFNγ in EBC from COPD patients could reflect the immunological status and the response of lung parenchyma to treatment during the exacerbation of the illness.  相似文献   

7.
The purpose of this inter-species comparison (calves and pigs) was to identify methodological and biological influences on the collection and composition of exhaled breath condensate (EBC). A total of 352 EBC samples were collected, whilst variables of ventilation were registered in parallel. Partial pressure of carbon dioxide (pCO2) and pH were analysed in non-degassed EBC samples. The concentration of total protein in EBC was measured colorimetrically. In both species, lung function was evaluated before and after EBC collection. Statistical analyses were performed to study the effect of EBC collection on lung function and to identify the influence of ventilatory variables on the collection and composition of EBC. Collection of EBC did not affect lung function. Despite the volume of EBC collected per unit time being primarily dependent on ventilation per unit time, species-specific conditions during the EBC collection process resulted in different dependences of EBC collection from other variables of ventilation (i.e. maximal airflow during expiration or expired tidal volume kg-1 body weight). The concentration of protein ml-1 EBC increased with the expired volume per min and with peak expiratory flow. Although the pCO2 in fresh EBC was significantly negatively dependent on the duration of collection, comparable pHs (5.6 - 6.2) were measured in EBC of both calves and pigs. The obtained data may help one standardize EBC collection in different species.  相似文献   

8.
Abstract

The purpose of this inter-species comparison (calves and pigs) was to identify methodological and biological influences on the collection and composition of exhaled breath condensate (EBC). A total of 352 EBC samples were collected, whilst variables of ventilation were registered in parallel. Partial pressure of carbon dioxide (pCO2) and pH were analysed in non-degassed EBC samples. The concentration of total protein in EBC was measured colorimetrically. In both species, lung function was evaluated before and after EBC collection. Statistical analyses were performed to study the effect of EBC collection on lung function and to identify the influence of ventilatory variables on the collection and composition of EBC. Collection of EBC did not affect lung function. Despite the volume of EBC collected per unit time being primarily dependent on ventilation per unit time, species-specific conditions during the EBC collection process resulted in different dependences of EBC collection from other variables of ventilation (i.e. maximal airflow during expiration or expired tidal volume kg?1 body weight). The concentration of protein ml?1 EBC increased with the expired volume per min and with peak expiratory flow. Although the pCO2 in fresh EBC was significantly negatively dependent on the duration of collection, comparable pHs (5.6???6.2) were measured in EBC of both calves and pigs. The obtained data may help one standardize EBC collection in different species.  相似文献   

9.
As a noninvasive method, exhaled breath condensate (EBC) has gained importance to improve monitoring of lung diseases and to detect biomarkers. The aim of the study was to investigate, whether erythropoietin (EPO) is detectable in EBC. EBC was collected from 22 consecutive patients as well as from healthy individuals. Using a multiplex fluorescent bead immunoassay, we detected EPO in EBC, as well as tumour necrosis factor-alpha (TNF-alpha) in 13 out of 22 patients simultaneously (EPO 0.21 +/- 0.03 in U/mL and TNF-alpha 34.6 +/- 4.2 in pg/mL, mean +/- SEM). No significant differences for EPO levels or correlation between EPO and TNF-alpha were found but TNF-alpha was significantly higher in patients with chronic obstructive pulmonary disease (COPD) than in non-COPD (obstructive sleep apnoea, OSA, and lung healthy patients). This is the first report of detection of EPO in EBC. Due to the small study size more data is needed to clarify the role of EPO in EBC.  相似文献   

10.
《Biomarkers》2013,18(7):583-593
Asthma-related symptoms can manifest in children during the early years, but only some of the children will develop the disease. This feasibility study showed that it is possible to apply non-invasive markers (in urine, exhaled nitric oxide (FENO) and exhaled breath condensate (EBC)) in 3-year-old children, and evaluated the biomarkers in relation to health outcomes and potential modifiers. FENO was correlated with respiratory allergy, and was borderline significantly correlated with wheezing, but not with the asthma predictive index (mAPI). EBC pH and urinary 8-oxo-deoxyguanosine were not significantly correlated with these clinical outcomes. An EBC proteolytic peptide pattern was developed, which could distinguish between mAPI-positive and -negative children. Non-invasive biomarkers may become a promising tool for investigating respiratory health in children but further research is needed.  相似文献   

11.
Reactive nitrogen species can cause oxidative modifications of certain amino acid residues in proteins, notably the modification of tyrosine to 3-nitrotyrosine (3-NT), which is a potentially useful marker of oxidative stress. Since lung diseases are associated with airway inflammation and oxidative stress, quantification of 3-NT in exhaled breath condensate (EBC) may provide a non-invasive means for monitoring ongoing inflammatory processes. 3-NT-like immunoreactivity has previously been detected in EBC, but no definitive evidence for the presence of 3-NT in EBC is available. Here, a method based on gas chromatography/negative ion chemical ionization/tandem mass spectrometry was established for the quantification of free 3-NT in EBC. The detection limit was 0.56 pM (corresponding to 3.0 amol microl(-1) sample injected) and the method was found to give linear results (r2 > 0.999) in the concentration range of 0-5.0 nM. The coefficient of variation (CV) for within-day and between-day precision were 11 and 12%, respectively. No artifactual nitration was observed during sample processing. The method was applied to study subjects with asthma (n = 8), and healthy subjects (n = 10), but only a slight non-significant increase in 3-NT levels was found in the former group (median [interquartile ranges]; 99 [50-547] amol s(-1) vs. 75 [35-147] amol s(-1)). No correlation with exhaled nitric oxide (NO), pulmonary function or EBC levels of total protein was observed. The 3-NT levels were much lower compared to previously reported levels, based on immunochemical measurements. The method does not allow the simultaneous quantification of tyrosine in samples.  相似文献   

12.
This veterinary study is aimed at further standardization of H2O2 and pH measurements in exhaled breath condensate (EBC). Data obtained in the study provide valuable information for many mammalian species including humans, and may help to avoid general pitfalls in interpretation of EBC data. EBC was sampled via the 'ECoScreen' in healthy calves (body weight 63-98 kg). Serum samples and condensates of ambient (indoor) air were collected in parallel. In the study on H2O2, concentrations of H2O2 in EBC, blood and ambient air were determined with the biosensor system 'ECoCheck'. In EBC, the concentration of H2O2 was found to be dependent on food intake and increased significantly in the course of the day. Physiologically, lowest H2O2 concentrations at 06:00 varied within the range 138-624 nmol l-1 EBC or 0.10-0.94 nmol per 100 l exhaled breath and individual concentrations were significantly different indicating a remarkable intersubject variability. Highly reproducible results were seen within each subject (three different days within 4 weeks). No correlation existed between H2O2 concentrations in EBC and blood, and EBC-H2O2 was not influenced by variables of spontaneous breathing. Further results confirmed that standardization of H2O2 measurements in EBC requires (1) the re-calculation of the concentration exhaled per 100 l exhaled breath (because the analyzed concentration in the liquid condensate underlies multiple methodological sources of variability given by the collection process), and (2) subtracting the concentration of inspired indoor H2O2. In the study on pH use of the ISFET electrode (Sentron, the Netherlands) and a blood gas analyzer ABL 550 (Radiometer, Denmark) led to comparable results for EBC-pH (r=0.89, R2=79.3%, p≤0.001). Physiological pH data in non-degassed EBC samples varied between 5.3 and 6.5, and were not significantly different between subjects, but were significantly higher in the evening compared with the morning. EBC-pH was not dependent on variables of spontaneous breathing pattern or ambient conditions, and no significant correlation was found between serum and EBC for pH.  相似文献   

13.
Abstract

This veterinary study is aimed at further standardization of H2O2 and pH measurements in exhaled breath condensate (EBC). Data obtained in the study provide valuable information for many mammalian species including humans, and may help to avoid general pitfalls in interpretation of EBC data. EBC was sampled via the ‘ECoScreen’ in healthy calves (body weight 63–98 kg). Serum samples and condensates of ambient (indoor) air were collected in parallel. In the study on H2O2, concentrations of H2O2 in EBC, blood and ambient air were determined with the biosensor system ‘ECoCheck’. In EBC, the concentration of H2O2 was found to be dependent on food intake and increased significantly in the course of the day. Physiologically, lowest H2O2 concentrations at 06:00 varied within the range 138–624 nmol l?1 EBC or 0.10–0.94 nmol per 100 l exhaled breath and individual concentrations were significantly different indicating a remarkable intersubject variability. Highly reproducible results were seen within each subject (three different days within 4 weeks). No correlation existed between H2O2 concentrations in EBC and blood, and EBC–H2O2 was not influenced by variables of spontaneous breathing. Further results confirmed that standardization of H2O2 measurements in EBC requires (1) the re-calculation of the concentration exhaled per 100 l exhaled breath (because the analyzed concentration in the liquid condensate underlies multiple methodological sources of variability given by the collection process), and (2) subtracting the concentration of inspired indoor H2O2. In the study on pH use of the ISFET electrode (Sentron, the Netherlands) and a blood gas analyzer ABL 550 (Radiometer, Denmark) led to comparable results for EBC–pH (r=0.89, R2=79.3%, p≤0.001). Physiological pH data in non-degassed EBC samples varied between 5.3 and 6.5, and were not significantly different between subjects, but were significantly higher in the evening compared with the morning. EBC–pH was not dependent on variables of spontaneous breathing pattern or ambient conditions, and no significant correlation was found between serum and EBC for pH.  相似文献   

14.
An ion chromatographic method with conductivity detection for the simultaneous quantification of sodium, ammonium and potassium in exhaled breath condensate (EBC) was developed and validated. A factorial design was used to optimize the chromatographic conditions, which resulted in baseline separations of the cations within 6 min. The method requires no pre-treatment of EBC samples. The optimized method was used for the intra-individual screening of cations in EBC of 10 healthy volunteers. The LOQs were low (0.3, 0.1 and 0.2 microM for sodium, ammonium and potassium, respectively), compared with levels detected in healthy volunteers. The responses were linear with good precision, and samples could be stored for at least 10 weeks at refrigerating conditions.  相似文献   

15.

Background

In asthma management guidelines the primary goal of treatment is asthma control. To date, asthma control, guided by symptoms and lung function, is not optimal in many children and adults. Direct monitoring of airway inflammation in exhaled breath may improve asthma control and reduce the number of exacerbations.

Aim

1) To study the use of fractional exhaled nitric oxide (FeNO) and inflammatory markers in exhaled breath condensate (EBC), in the prediction of asthma exacerbations in a pediatric population. 2) To study the predictive power of these exhaled inflammatory markers combined with clinical parameters.

Methods

96 asthmatic children were included in this one-year prospective observational study, with clinical visits every 2 months. Between visits, daily symptom scores and lung function were recorded using a home monitor. During clinical visits, asthma control and FeNO were assessed. Furthermore, lung function measurements were performed and EBC was collected. Statistical analysis was performed using a test dataset and validation dataset for 1) conditionally specified models, receiver operating characteristic-curves (ROC-curves); 2) k-nearest neighbors algorithm.

Results

Three conditionally specified predictive models were constructed. Model 1 included inflammatory markers in EBC alone, model 2 included FeNO plus clinical characteristics and the ACQ score, and model 3 included all the predictors used in model 1 and 2. The area under the ROC-curves was estimated as 47%, 54% and 59% for models 1, 2 and 3 respectively. The k-nearest neighbors predictive algorithm, using the information of all the variables in model 3, produced correct predictions for 52% of the exacerbations in the validation dataset.

Conclusion

The predictive power of FeNO and inflammatory markers in EBC for prediction of an asthma exacerbation was low, even when combined with clinical characteristics and symptoms. Qualitative improvement of the chemical analysis of EBC may lead to a better non-invasive prediction of asthma exacerbations.  相似文献   

16.
The quantitative determination of 3-nitro-l-tyrosine, a biological marker for inflammatory processes, in exhaled breath condensate (EBC) is described. The clean-up and preconcentration was performed by solid phase extraction (SPE). After liquid chromatography the specific detection was performed by tandem mass spectrometry using electron spray ionisation and selected reaction monitoring (SRM). 13C9-3-nitrotyrosine was used as an internal standard. For reliability, tests for the precision of the method, the losses during preparation, a test for nitrating artifacts and the comparibility of calibrants in EBC and buffer solution were performed. The calibration of the method was linear over a range of 10-500 pg/mL. The within-run coefficients of variation (CV) of the samples were found to be 8.4% at 25 pg/mL and 8.3% at 250 pg/mL. The day-to-day CV was found to be 11.2%. The limit of quantification was 3.9 pg/mL. The losses during preparation were 15%. The discrepancy between the calibration with EBC and buffer solution was below 10%. No artificial production of 3-nitrotyrosine was observed during the procedure. The application of the method on the EBC samples of healthy smokers (N=10) and non-smokers (N=10) showed no difference between the two groups. The concentration of 3-nitrotyrosine ranged between the limit of quantification and 184 pg/mL and was distinctly lower than data detected by an immunoassay procedure. The procedure was proven to be accurate, sensitive and in contrast to GC methods less elaborate and is recommended for the determination of 3-nitrotyrosine in exhaled breath condensate.  相似文献   

17.

Background

Analysis of exhaled breath condensate (EBC) is a non-invasive method for studying the acidity (pH) of airway secretions in patients with inflammatory lung diseases.

Aim

To assess the reproducibility of EBC pH for two commercially available devices (portable RTube and non-portable ECoScreen) in healthy controls, patients with asthma or COPD, and subjects suffering from an acute cold with lower-airway symptoms. In addition, we assessed the repeatability in healthy controls.

Methods

EBC was collected from 40 subjects (n = 10 in each of the above groups) using RTube and ECoScreen. EBC was collected from controls on two separate occasions within 5 days. pH in EBC was assessed after degasification with argon for 20 min.

Results

In controls, pH-measurements in EBC collected by RTube or ECoScreen showed no significant difference between devices (p = 0.754) or between days (repeatability coefficient RTube: 0.47; ECoScreen: 0.42) of collection. A comparison between EBC pH collected by the two devices in asthma, COPD and cold patients also showed good reproducibility. No differences in pH values were observed between controls (mean pH 8.27; RTube) and patients with COPD (pH 7.97) or asthma (pH 8.20), but lower values were found using both devices in patients with a cold (pH 7.56; RTube, p < 0.01; ECoScreen, p < 0.05).

Conclusion

We conclude that pH measurements in EBC collected by RTube and ECoScreen are repeatable and reproducible in healthy controls, and are reproducible and comparable in healthy controls, COPD and asthma patients, and subjects with a common cold.  相似文献   

18.

Background

Recent studies suggest that humans exhale fine particles during tidal breathing but little is known of their composition, particularly during infection.

Methodology/Principal Findings

We conducted a study of influenza infected patients to characterize influenza virus and particle concentrations in their exhaled breath. Patients presenting with influenza-like-illness, confirmed influenza A or B virus by rapid test, and onset within 3 days were recruited at three clinics in Hong Kong, China. We collected exhaled breath from each subject onto Teflon filters and measured exhaled particle concentrations using an optical particle counter. Filters were analyzed for influenza A and B viruses by quantitative polymerase chain reaction (qPCR). Twelve out of thirteen rapid test positive patients provided exhaled breath filter samples (7 subjects infected with influenza B virus and 5 subjects infected with influenza A virus). We detected influenza virus RNA in the exhaled breath of 4 (33%) subjects–three (60%) of the five patients infected with influenza A virus and one (14%) of the seven infected with influenza B virus. Exhaled influenza virus RNA generation rates ranged from <3.2 to 20 influenza virus RNA particles per minute. Over 87% of particles exhaled were under 1 µm in diameter.

Conclusions

These findings regarding influenza virus RNA suggest that influenza virus may be contained in fine particles generated during tidal breathing, and add to the body of literature suggesting that fine particle aerosols may play a role in influenza transmission.  相似文献   

19.
Study of proteomic composition of exhaled breath condensate (EBC) is a promising non-invasive method for diagnostics of respiratory system diseases in patients. In this study the EBC proteomic composition of 53 donors, including patients with different respiratory system diseases has been investigated. Cytoskeletal keratins type II (1, 2, 3, 4, 5, 6) and cytoskeletal keratins type I (9, 10, 14, 15, 16) were invariant for all samples. Analyzing the frequency of occurrence of proteins in different groups of examined patients, several categories of proteins have been recognized: proteins found in all pathologies (dermcidin, alpha-1- microglobulin, SHROOM3), proteins simultaneously found in two groups (CSTA, LCN1, JUP, PIP, TXN), and proteins specific for a particular group (PRDX1, annexin A1/A2). The EBC analysis by HPLC-MS/MS can be used for identification of potential protein markers specific for inflammatory pulmonary diseases of infective origin (pneumonia) as well as for non-infectious diseases such as chronic obstructive pulmonary disease (COPD).  相似文献   

20.
Biomarkers in exhaled breath are useful for respiratory disease diagnosis in human volunteers. Conventional methods that collect non-volatile biomarkers, however, necessitate an extensive dilution and sanitation processes that lowers collection efficiencies and convenience of use. Electret filter emerged in recent decade to collect virus biomarkers in exhaled breath given its simplicity and effectiveness. To investigate the capability of electret filters to collect protein biomarkers, a model that consists of an atomizer that produces protein aerosol and an electret filter that collects albumin and carcinoembryonic antigen-a typical biomarker in lung cancer development- from the atomizer is developed. A device using electret filter as the collecting medium is designed to collect human albumin from exhaled breath of 6 volunteers. Comparison of the collecting ability between the electret filter method and other 2 reported methods is finally performed based on the amounts of albumin collected from human exhaled breath. In conclusion, a decreasing collection efficiency ranging from 17.6% to 2.3% for atomized albumin aerosol and 42% to 12.5% for atomized carcinoembryonic antigen particles is found; moreover, an optimum volume of sampling human exhaled breath ranging from 100 L to 200 L is also observed; finally, the self-designed collecting device shows a significantly better performance in collecting albumin from human exhaled breath than the exhaled breath condensate method (p<0.05) but is not significantly more effective than reported 3-stage impactor method (p>0.05). In summary, electret filters are potential in collecting non-volatile biomarkers in human exhaled breath not only because it was simpler, cheaper and easier to use than traditional methods but also for its better collecting performance.  相似文献   