首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The present study investigated the effects of three centrally acting drugs on the significant increase in the intermediate alpha frequency of the electroencephalogram (EEG) that accompanied meditation in a male volunteer. When compared to the EEG recorded before each of the three drugs was administered, naloxone tended to enhance the increase in the power of the intermediate alpha EEG (9.4-10.4 Hz), while diazepam tended to spread the increase to the slow (7.4-9.4 Hz) alpha EEG, and flumazenil was without much effect on the overall EEG pattern. However, these EEG changes when compared to similar changes obtained with saline administration were not significantly different from the latter. Thus, it is unlikely that the EEG correlates of meditation are causally related to the rise or fall of endogenous opioid peptides or benzodiazepinelike substances in the brain.  相似文献   

2.
The EEG effects of intake of the mean therapeutic single dose of cholinomimetic amiridin (20 mg) or cholinolytic amizyl (2 mg) were studied in 7 healthy subjects. After the intake of the drugs with agonistic and antagonistic action, significant opposite changes in the EEG spectral density were observed in the frequency ranges of 0.6-6.7, 7.7-11.4, and 24.8-29.7 Hz. Amizyl produced an enhancement of the spectral density of the delta-, theta- and beta 2 activity and reduction of the alpha-rhythm power, while under the action of amiridin the spectral density of these rhythms changed in opposite directions. The oppositely directed changes in the alpha range were most pronounced. The peak frequency of amiridin-induced shift was equal to 9.8-10 Hz, and the same value of the spectral change induced by amizyl was 10.8-11.4 Hz. It is suggested that the spectral power density of the alpha-rhythm is an EEG index of the level of cholinergic activation.  相似文献   

3.
Mantra meditation is easy to practice. “OM” Mantra is the highest sacred symbol in Hinduism. The present study investigated the temporal dynamics of oscillatory changes after OM mantra meditation. Twenty-three naive meditators were asked to perform loud OM chanting for 30 min and the EEG were subsequently recorded with closed eyes before and after it. To obtain new insights into the nature of the EEG after OM chanting, EEG signals were analyzed using spectral domain analysis. Statistical analysis was performed using repeated measures of analysis of variance. It did not reveal any specific band involvement into OM mantra meditation. But significantly increase in theta power was found after meditation when averaged across all brain regions. This is the main effect of OM mantra meditation. However, the theta power showed higher theta amplitude after condition at all regions in comparison to the before condition of meditation. Finding was similar to other studies documenting reduction in cortical arousal during a state of relaxation. The study argues for the potential role of loud ‘OM’ chanting in offering relaxation. It provides a new perspective of meditation to the naive meditators. This information may help to demystify meditation and encourage those considering this as beneficial practice.  相似文献   

4.
The present study investigated the effects of three centrally acting drugs on the significant increase in the intermediate alpha frequency of the electroencephalogram (EEG) that accompanied meditation in a male volunteer. When compared to the EEG recorded before each of the three drugs was administered, naloxone tended to enhance the increase in the power of the intermediate alpha EEG (9.4–10.4 Hz), while diazepam tended to spread the increase to the slow (7.4–9.4 Hz) alpha EEG, and flumazenil was without much effect on the overall EEG pattern. However, these EEG changes when compared to similar changes obtained with saline administration were not significantly different from the latter. Thus, it is unlikely that the EEG correlates of meditation are causally related to the rise or fall of endogenous opioid peptides or benzodiazepinelike substances in the brain.This research was supported by a grant from the Singapore Turf Club (STC 4837). The authors would like to thank the subject for volunteering as a subject in this study; and Ms. Chua Mui Eng for her technical assistance.  相似文献   

5.
The development of the resonance EEG responses of the left and right occipital areas was studied in right-handed men during prolonged (12 or 120 s) rhythmic, photostimulation with the intensity of 0.7 J and frequencies of 6, 10, and 16 Hz. Analysis of the EEG fine spectral structure was applied to compare the accumulated baseline EEG spectra and EEG spectra during photostimulation, to observe the dynamics of the short-term spectra and to detect power changes in the EEG narrow spectral band sharply coincident with the stimulation frequency. The more pronounced EEG responses to photostimulation were observed in subjects with the initially low EEG baseline, α-rhythm. Two-minute flash trains produced a substantial increase in the EEG power within the stimulation frequency with superposed oscillatory processes with different periods. These fluctuations are considered a reflection of intricate interaction between the adaptive and resonance EEG responses to the presented intermittent stimulation. Under 12-s stimulation the resonance EEG responses are steadily recorded within the first 3 s of stimulation and immediately after the flash cessation EEG power at the stimulation frequency returns to the initial level. The resonance EEG responses were more pronounced in the right hemisphere than in the left one, especially, at the stimulation frequencies of 6 and 16 Hz. With increasing the stimulation frequency, the maximum of resonance EEG responses was reached earlier. Under the stimulation frequency of 6 Hz, the maximal response was recorded 9–12 s after the beginning of flashes, at the frequencies of 10 and 16 Hz, it was recorded within 3–6 and 3 s, respectively.  相似文献   

6.
Two sinusoidal signals, one with a constant frequency of 13 Hz and the other with a frequency continuously changing from 1 to 6 Hz and back, were presented simultaneously to subjects through spectacles with light-emitting diodes either to both eyes as a product (amplitude modulation of a constant frequency by a variable one) or to each eye separately. Both kinds of variable frequency exposure revealed a rhomboid pattern of the resonance activation of the EEG spectrum, similar to the spectral dynamics of a signal subject to amplitude modulation. This testifies to the key role of EEG amplitude modulation in the responses of the nervous system to variable frequency rhythmic stimuli. Both types of photic stimulation led to a substantial increase in EEG spectral density and improved the subjects' self-rating of the overall state of well-being, activity, and mood. In addition, separate stimulation of each eye led to an improvement in the anxiety and exercise performance indices (the Luscher color test) and a significant correlation between the intensity of EEG responses and changes in the general state. These differences are explained in terms of the involvement of the interhemispheric interaction mechanisms in the processing of complex rhythmic signals by the brain.  相似文献   

7.
Over the past several years meditation practice has gained increasing attention as a non-pharmacological intervention to provide health related benefits, from promoting general wellness to alleviating the symptoms of a variety of medical conditions. However, the effects of meditation training on brain activity still need to be fully characterized. Sleep provides a unique approach to explore the meditation-related plastic changes in brain function. In this study we performed sleep high-density electroencephalographic (hdEEG) recordings in long-term meditators (LTM) of Buddhist meditation practices (approximately 8700 mean hours of life practice) and meditation naive individuals. We found that LTM had increased parietal-occipital EEG gamma power during NREM sleep. This increase was specific for the gamma range (25–40 Hz), was not related to the level of spontaneous arousal during NREM and was positively correlated with the length of lifetime daily meditation practice. Altogether, these findings indicate that meditation practice produces measurable changes in spontaneous brain activity, and suggest that EEG gamma activity during sleep represents a sensitive measure of the long-lasting, plastic effects of meditative training on brain function.  相似文献   

8.
Changes in spatial organization of EEG activity were analyzed in 44 humans during active 1-h hyperventilation using cyclic or circular breath (CB) technique similar to rebirthing breath technique. The dynamics of different indices was recorded each 5 min (using 12 time slots). A double-humped pattern of changes in spatial organization indices (linear processes) and spatial disorder (nonlinear processes) of biopotentials: an initial decrease within 1 to 20–30 min and a second one from 35–40 min to the end of session. A complex dynamics of spatial frequency processes (coherence and spectral power of biopotentials) with different pattern of changes within narrow frequency EEG bands. The dynamics of the spatial organization of EEG indices proved to depend on the intensity of hyperventilation-induced paroxysmal activity. The indices of spatial synchronization and disorder of biopotentials as well as low frequency β-activity (16.00–22.50 Hz) decreased more at the background of high rather than low paroxysmal activity, while the low frequency components (Δ and Θ) and high frequency α-activity (11.25–12.50 Hz) increased more. The obtained data are considered in terms of specific consciousness state induced by CB.  相似文献   

9.
ObjectiveAlmost two-thirds of patients with Sturge-Weber syndrome (SWS) have epilepsy, and half of them require surgery for it. However, it is well known that scalp electroencephalography (EEG) does not demonstrate unequivocal epileptic discharges in patients with SWS. Therefore, we analyzed interictal and ictal discharges from intracranial subdural EEG recordings in patients treated surgically for SWS to elucidate epileptogenicity in this disorder.MethodsFive intractable epileptic patients with SWS who were implanted with subdural electrodes for presurgical evaluation were enrolled in this study. We examined the following seizure parameters: seizure onset zone (SOZ), propagation speed of seizure discharges, and seizure duration by visual inspection. Additionally, power spectrogram analysis on some frequency bands at SOZ was performed from 60 s before the visually detected seizure onset using the EEG Complex Demodulation Method (CDM).ResultsWe obtained 21 seizures from five patients for evaluation, and all seizures initiated from the cortex under the leptomeningeal angioma. Most of the patients presented with motionless staring and respiratory distress as seizure symptoms. The average seizure propagation speed and duration were 3.1 ± 3.6 cm/min and 19.4 ± 33.6 min, respectively. Significant power spectrogram changes at the SOZ were detected at 10–30 Hz from 15 s before seizure onset, and at 30–80 Hz from 5 s before seizure onset.SignificanceIn patients with SWS, seizures initiate from the cortex under the leptomeningeal angioma, and seizure propagation is slow and persists for a longer period. CDM indicated beta to low gamma-ranged seizure discharges starting from shortly before the visually detected seizure onset. Our ECoG findings indicate that ischemia is a principal mechanism underlying ictogenesis and epileptogenesis in SWS.  相似文献   

10.
The process by which the brain transitions into an epileptic seizure is unknown. In this study, we investigated whether the transition to seizure is associated with changes in brain dynamics detectable in the wideband EEG, and whether differences exist across underlying pathologies. Depth electrode ictal EEG recordings from 40 consecutive patients with pharmacoresistant lesional focal epilepsy were low-pass filtered at 500 Hz and sampled at 2,000 Hz. Predefined EEG sections were selected immediately before (immediate preictal), and 30 seconds before the earliest EEG sign suggestive of seizure activity (baseline). Spectral analysis, visual inspection and discrete wavelet transform were used to detect standard (delta, theta, alpha, beta and gamma) and high-frequency bands (ripples and fast ripples). At the group level, each EEG frequency band activity increased significantly from baseline to the immediate preictal section, mostly in a progressive manner and independently of any modification in the state of vigilance. Preictal increases in each frequency band activity were widespread, being observed in the seizure-onset zone and lesional tissue, as well as in remote regions. These changes occurred in all the investigated pathologies (mesial temporal atrophy/sclerosis, local/regional cortical atrophy, and malformations of cortical development), but were more pronounced in mesial temporal atrophy/sclerosis. Our findings indicate that a brain state change with distinctive features, in the form of unidirectional changes across the entire EEG bandwidth, occurs immediately prior to seizure onset. We postulate that these changes might reflect a facilitating state of the brain which enables a susceptible region to generate seizures.  相似文献   

11.
Seizure forecasting has the potential to create new therapeutic strategies for epilepsy, such as providing patient warnings and delivering preemptive therapy. Progress on seizure forecasting, however, has been hindered by lack of sufficient data to rigorously evaluate the hypothesis that seizures are preceded by physiological changes, and are not simply random events. We investigated seizure forecasting in three dogs with naturally occurring focal epilepsy implanted with a device recording continuous intracranial EEG (iEEG). The iEEG spectral power in six frequency bands: delta (0.1–4 Hz), theta (4–8 Hz), alpha (8–12 Hz), beta (12–30 Hz), low-gamma (30–70 Hz), and high-gamma (70–180 Hz), were used as features. Logistic regression classifiers were trained to discriminate labeled pre-ictal and inter-ictal data segments using combinations of the band spectral power features. Performance was assessed on separate test data sets via 10-fold cross-validation. A total of 125 spontaneous seizures were detected in continuous iEEG recordings spanning 6.5 to 15 months from 3 dogs. When considering all seizures, the seizure forecasting algorithm performed significantly better than a Poisson-model chance predictor constrained to have the same time in warning for all 3 dogs over a range of total warning times. Seizure clusters were observed in all 3 dogs, and when the effect of seizure clusters was decreased by considering the subset of seizures separated by at least 4 hours, the forecasting performance remained better than chance for a subset of algorithm parameters. These results demonstrate that seizures in canine epilepsy are not randomly occurring events, and highlight the feasibility of long-term seizure forecasting using iEEG monitoring.  相似文献   

12.

Study Objectives

We have recently shown higher parietal-occipital EEG gamma activity during sleep in long-term meditators compared to meditation-naive individuals. This gamma increase was specific for NREM sleep, was present throughout the entire night and correlated with meditation expertise, thus suggesting underlying long-lasting neuroplastic changes induced through prolonged training. The aim of this study was to explore the neuroplastic changes acutely induced by 2 intensive days of different meditation practices in the same group of practitioners. We also repeated baseline recordings in a meditation-naive cohort to account for time effects on sleep EEG activity.

Design

High-density EEG recordings of human brain activity were acquired over the course of whole sleep nights following intervention.

Setting

Sound-attenuated sleep research room.

Patients or Participants

Twenty-four long-term meditators and twenty-four meditation-naïve controls.

Interventions

Two 8-h sessions of either a mindfulness-based meditation or a form of meditation designed to cultivate compassion and loving kindness, hereafter referred to as compassion meditation.

Measurements and Results

We found an increase in EEG low-frequency oscillatory activities (1–12 Hz, centered around 7–8 Hz) over prefrontal and left parietal electrodes across whole night NREM cycles. This power increase peaked early in the night and extended during the third cycle to high-frequencies up to the gamma range (25–40 Hz). There was no difference in sleep EEG activity between meditation styles in long-term meditators nor in the meditation naïve group across different time points. Furthermore, the prefrontal-parietal changes were dependent on meditation life experience.

Conclusions

This low-frequency prefrontal-parietal activation likely reflects acute, meditation-related plastic changes occurring during wakefulness, and may underlie a top-down regulation from frontal and anterior parietal areas to the posterior parietal and occipital regions showing chronic, long-lasting plastic changes in long-term meditators.  相似文献   

13.
1. Changes in EEG power spectrum of carp to a priming non-acoustic stimulus followed by acoustic clicks were compared to those due to acoustic clicks delivered alone. Recordings were made from the telencephalon, midbrain and medulla. Acoustic evoked potentials (AEPs) to the clicks were also recorded. 2. EEG power changes to non-acoustic stimuli occurred over the whole 1-40 Hz frequency range and were regionally specific and consistent. 3. The changes in the EEG midfrequency 12-24 Hz power spectrum to non-acoustic stimuli were significantly correlated with changes in the AEP to subsequent clicks. An elevated medullary AEP amplitude and reduced duration were correlated with increased medullary EEG power and increased midbrain AEP duration. 4. Telencephalic EEG power changes were inversely related to changes in medullary and midbrain AEP amplitude.  相似文献   

14.
A new computerized method for EEG rhythms extraction is proposed as a development of the idea of adjustable boundaries of frequency components that was put forward in previous investigations. Principle component analysis of the correlation matrix of EEG spectra with subsequent rotation of factor solutions was used for decomposition of a spectrum into physically meaningful spectral components. The method was tested on EEG of 14 healthy subjects recorded in 17 functional waking states. Fourteen independent spectral components in the spectral range from 0 to 100 Hz were extracted and their frequency boundaries were consistent with the current knowledge on frequency components of EEG oscillations. Main advantage of the described method is the adjustable estimation of EEG frequency oscillators taking into account characteristic properties of individual EEGs. Possible area of application might be the correct evaluation of spectral power of the EEG rhythms, EEG coherence and other spectral characteristics in clinical and experimental research, studies of the frequency characteristics of the EEG rhythms in different human functional states, changes in frequency characteristics of the EEG rhythms during maturation and in mental pathology.  相似文献   

15.
A closed-loop system for the automated detection and control of epileptic seizures was created and tested in three Genetic Absence Epilepsy Rats from Strasbourg (GAERS) rats. In this preliminary study, a set of four EEG features were used to detect seizures and three different electrical stimulation strategies (standard (130 Hz), very high (500 Hz) and ultra high (1000 Hz)) were delivered to terminate seizures. Seizure durations were significantly shorter with all three stimulation strategies when compared to non-stimulated (control) seizures. We used mean seizure duration of epileptiform discharges persisting beyond the end of electrical stimulation as a measure of stimulus efficacy. When compared to the duration of seizures stimulated in the standard approach (7.0 s ± 10.1), both very high and ultra high frequency stimulation strategies were more effective at shortening seizure durations (1.3 ± 2.2 s and 3.5 ± 6.4 s respectively). Further studies are warranted to further understand the mechanisms by which this therapeutic effect may be conveyed, and which of the novel aspects of the very high and ultra high frequency stimulation strategies may have contributed to the improvement in seizure abatement performance when compared to standard electrical stimulation approaches.  相似文献   

16.
With the advancement of contemporary techniques for studies of high-frequency electroencephalograms (EEGs), possible contamination of the EEG with the electromyogram (EMG) of pericranial muscles has raised more and more concern. The aim of the present study was to demonstrate if certain EEG correlates of mental activities can be revealed in a high-frequency scalp EEG in spite of EMG contamination. Nineteen healthy women who performed similar test tasks before and after cosmetic injections of Dysport in various facial regions for reduction of the activity of facial muscles took part in the study. Inductions of emotional states with different valences, memory storing, and extraction of verbal information were used in the test tasks. The default state of rest was examined as well. During performance of the tasks, parallel registrations of the EEG from the scalp surface (19 channels) and EMG from several facial muscles (6 channels) were carried out. Changes in the spectral power in β2 and low γ frequency bands (18–40 Hz) in EEG- and EMG-derivations after Dysport injections were analyzed. Changes in the spectral power in the same bands in pairwise comparisons for the test tasks before and after Dysport injections were also analyzed separately. It was demonstrated that Dysport injections lead to reduction of the EMG power in areas of the injections and to reduction of EEG power in the frontal and temporal derivations. However, the EEG-correlates revealed when comparing different test tasks remained qualitatively invariable as for after and before Disport injections. These facts confirm that EMG makes a noticeable contribution to the electric activity registered from the scalp in the frequency ranges greater than 18 Hz. At the same time, one can see that at least in certain experimental situations the influence of EMG does not make impossible identification of EEG-correlates of mental activity with EEG registration from the head surface at least in the β2 and low γ frequency bands (18–40 Hz).  相似文献   

17.
The Sensorium is a multimodal neurofeedback environment that reflects a person’s physiological state by presenting physiological signals via orchestral sounds from a speaker and multi-coloured lights projected onto a white surface. The software manages acquisition, real-time processing, storage, and sonification of various physiological signals such as the electroencephalogram (EEG) or electrocardiogram (ECG). Each of the 36 participants completed 6 interventional conditions consisting of three different Sensorium-phases with EEG and ECG feedback, a mindfulness meditation, a guided body scan exercise, and a Pseudo-Sensorium using pre-recorded data that did not reflect the subject’s own physiology. During all phases EEG, ECG, skin conductance, and respiration were recorded. A feedback questionnaire assessed the participants’ subjective reports of changes in well-being, perception, and life-spirit. The results indicate that the Sensorium sessions were not statistically inferior compared to their corresponding active control conditions with respect to improvements in subjective reports concerning well-being and perception. Additionally, the Sensorium was rated as being a more extraordinary experience, as compared to meditation. During the Sensorium conditions the EEG showed lower levels of theta2 (7–8.5 Hz), alpha (9–12 Hz) and beta (12.5–25 Hz) activity. Since participants reported benefit from the Sensorium experience regardless of any prior experience with meditation, we propose this novel method of meditative and extraordinary self-experience to be utilized as a modern alternative to more traditional forms of meditation.  相似文献   

18.
It has been reported that human subjects exposed to electromagnetic fields exhibit changes in human EEG signals at the frequency of stimulation. The aim of the present study was to expose different parts of the brain to extremely low-frequency magnetic fields locally and investigate EEG power spectrum alters at the frequency of stimulation. EEG relative power spectrum were evaluated at 3, 5, 10, 17, and 45 Hz frequencies at T4, T3, F3, Cz, and F4 points, respectively, when these points were exposed to magnetic fields with similar frequencies and 100 μT intensity. The paired t-test results showed that power value of EEG did not alter significantly at the frequency of stimulation (P<0.05). Further, significant changes in different EEG bands caused by locally exposing to ELF-MF in different points of brain were observed. The changes in the EEG bands were not limited necessarily to the exposure point.  相似文献   

19.
It has been reported that human subjects exposed to electromagnetic fields exhibit changes in human EEG signals at the frequency of stimulation. The aim of the present study was to expose different parts of the brain to extremely low-frequency magnetic fields locally and investigate EEG power spectrum alters at the frequency of stimulation. EEG relative power spectrum were evaluated at 3, 5, 10, 17, and 45 Hz frequencies at T4, T3, F3, Cz, and F4 points, respectively, when these points were exposed to magnetic fields with similar frequencies and 100 μT intensity. The paired t-test results showed that power value of EEG did not alter significantly at the frequency of stimulation (P < 0.05). Further, significant changes in different EEG bands caused by locally exposing to ELF-MF in different points of brain were observed. The changes in the EEG bands were not limited necessarily to the exposure point.  相似文献   

20.
Fedotchev AI 《Biofizika》2001,46(1):112-117
The features of resonance phenomena in high-resolution EEG structure were analyzed for two intensities and three values of duration of exposure to 20 constant frequencies of intermittent photic stimulation in a range of 1-20 Hz with 1 Hz steps. It was shown that with a 6 s step duration, an irregular activation of multiple spectral EEG components for both light intensities occurs. With longer durations (12 and 18 s) of fixed-frequency stimulation, the EEG reactions are of resonance nature. Low-intensity flashes cause only the resonance activation of the intrinsic oscillator in the range of dominant alpha-EEG frequency. During a more intensive stimulation, the resonance EEG phenomena are observed for the whole range of stimulation frequencies. The interval of 6-12 s is supposed to be the relaxation period for a system of brain electrical activity generation. After this time, the low-intensity stimuli cause the adaptation of the system to light, whereas more intensive flashes cause more pronounced resonance EEG phenomena and physiological effects.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号