首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 437 毫秒
1.
The choline head group containing phosphatidylcholine (PC) and sphingomyelin (SPM) are major eukaryotic lipid components playing an important role in forming membrane microdomains and serve as precursor of signaling molecules. Both lipids can be monitored by positive ion mode electrospray tandem mass spectrometry using a parent ion scan of m/z 184. Although PC species appear at even m/z and SPM species at odd m/z, there may be a significant overlap of their isotopes. In order to separate PC and SPM species, an isotope correction algorithm was established, which utilizes calculated isotope percentages to correct the measured peak intensities for their isotopic overlap. We could demonstrate that this approach was applicable to correct the isotope overlap resulting from spiked PC and SPM species. Quantification was achieved by addition of different PC and SPM species prior to lipid extraction. The developed assay showed a precision, detection limit and robustness sufficient for routine analysis. Furthermore, an analysis time of only 1.3 min combined with automated data analysis using self-programmed Excel Macros allows high-throughput analysis. In summary, this assay may be a valuable tool for detailed lipid analysis of PC and SPM species in a variety of sample materials.  相似文献   

2.
《Journal of Proteomics》2010,73(2):357-360
We developed a software program (titled Precursor Ion Calibration software for LTQ or, in short, PICsL) that increases the reliability of precursor ion assignations from LC-MS analysis using ultra zoom scanning of LTQ linear ion trap MS and automatically corrects the assignations. Although existing software calculates the theoretical isotopic distribution according to m/z with a computational algorithm, our method simply searches for ions close to the theoretical mass value using both MS/MS raw data and Mascot search result files, followed by a second database search that identifies the proteins using the regenerated peak list files. Our software program mimics the manual inspection of the spectral data of precursor ions and is expected to be applicable not only for low resolution MS, such as LTQ, but also for a wide variety of MS instruments.  相似文献   

3.
We report the results of our work to facilitate protein identification using tandem mass spectra and protein sequence databases. We describe a parallel version of SEQUEST (SEQUEST-PVM) that is tolerant toward arithmetic exceptions. The changes we report effectively separate search processes on slave nodes from each other. Therefore, if one of the slave nodes drops out of the cluster due to an error, the rest of the cluster will carry the search process to the end. SEQUEST has been widely used for protein identifications. The modifications made to the code improve its stability and effectiveness in a high-throughput production environment. We evaluate the overhead associated with the parallelization of SEQUEST. A prior version of software to preprocess LC/MS/MS data attempted to differentiate the charge states of ions. Singly charged ions can be accurately identified, but the software was unable to reliably differentiate tandem mass spectra of +2 and +3 charge states. We have designed and implemented a computational approach to narrow charge states of precursor ions from nominal resolution ion-trap tandem mass spectra. The preprocessing code, 2to3, determines the charge state of the precursor ion using its mass-to-charge ratio (m/z) and fragment ions contained in the tandem mass spectrum. For each possible charge state the program calculates the expected fragment ions that account for precursor ion m/z values. If any one of the numbers is less than an empirically determined threshold value then the spectrum corresponding to that charge state is removed. If both numbers are higher than the threshold value then +2 and +3 copies of the spectrum are kept. We present the comparison of results from protein identification experiments with and without using 2 to 3. It is shown that by determining the charge state and eliminating poor quality spectra 2to3 decreases the number of spectral files to be searched without affecting the search results. The decrease reduces computer requirements and researcher efforts for analysis of the results.  相似文献   

4.
We performed a large scale study of electron transfer dissociation (ETD) performance, as compared with ion trap collision-activated dissociation (CAD), for peptides ranging from approximately 1000 to 5000 Da (n approximately 4000). These data indicate relatively little overlap in peptide identifications between the two methods ( approximately 12%). ETD outperformed CAD for all charge states greater than 2; however, regardless of precursor charge a linear decrease in percent fragmentation, as a function of increasing precursor m/z, was observed with ETD fragmentation. We postulate that several precursor cation attributes, including peptide length, charge distribution, and total mass, could be relevant players. To examine these parameters unique ETD-identified peptides were sorted by length, and the ratio of amino acid residues per precursor charge (residues/charge) was calculated. We observed excellent correlation between the ratio of residues/charge and percent fragmentation. For peptides of a given residue/charge ratio, there is no correlation between peptide mass and percent fragmentation; instead we conclude that the ratio of residues/charge is the main factor in determining a successful ETD outcome. As charge density decreases so does the probability of non-covalent interactions that can bind a newly formed c/z-type ion pair. Recently we have described a supplemental activation approach (ETcaD) to convert these non-dissociative electron transfer product ions to useful c- and z-type ions. Automated implementation of such methods should remove this apparent precursor m/z ceiling. Finally, we evaluated the role of ion density (both anionic and cationic) and reaction duration for an ETD experiment. These data indicate that the best performance is achieved when the ion trap is filled to its space charge limit with anionic reagents. In this largest scale study of ETD to date, ETD continues to show great promise to propel the field of proteomics and, for small- to medium-sized peptides, is highly complementary to ion trap CAD.  相似文献   

5.
S J Gaskell 《Steroids》1990,55(10):458-462
Fast atom bombardment/mass spectrometry or liquid secondary ion mass spectrometry provides the capability for direct analysis of steroid conjugates (sulfates, glucuronides) without prior hydrolysis or derivatization. During the analysis of biologic extracts, limitations on the sensitivity of detection arise from the presence of co-extracted material which may suppress or obscure the analyte signal. A procedure is described for the quantitative determination of dehydroepiandrosterone sulfate in serum which achieved selective isolation of the analyte using immunoadsorption extraction and highly specific detection using tandem mass spectrometry. A stable isotope-labeled analog [( 2H2]dehydroepiandrosterone sulfate) was used as internal standard. Fast atom bombardment of dehydroepiandrosterone sulfate yielded abundant [M-H]- ions that fragmented following collisional activation to give HSO4-; m/z 97. During fast atom bombardment/tandem mass spectrometry of serum extracts, a scan of precursor ions fragmenting to give m/z 97 detected dehydroepiandrosterone sulfate and the [2H2]-labeled analog with a selectivity markedly superior to that observed using conventional mass spectrometry detection. Satisfactory agreement was observed between quantitative data obtained in this way and data obtained by gas chromatography/mass spectrometry of the heptafluorobutyrates of dehydroepiandrosterone sulfate and [2H2]dehydroepiandrosterone sulfate obtained by direct derivatization.  相似文献   

6.
We present a software algorithm that combines ion trap and orbitrap product ion spectra acquired in parallel. The hybrid product ion spectra identify more peptides than when using two separate searches for the orbitrap and LTQ data. The program extracts the high-accuracy mass data from the Orbitrap mass analyzer and combines it with the high-sensitivity data analyzed in the LTQ linear ion trap; the m/z values of the high-confidence fragment ions are corrected to orbitrap mass accuracies and the fragment ion intensities are amplified. This approach utilizes the parallel spectrum measurement capabilities of the LTQ-Orbitrap. We present our approach to handling this type of hybrid data, explain our alignment program, and discuss the advantages of the chosen methodology.  相似文献   

7.
Methods for treating MS/MS data to achieve accurate peptide identification are currently the subject of much research activity. In this study we describe a new method for filtering MS/MS data and refining precursor masses that provides highly accurate analyses of massive sets of proteomics data. This method, coined "postexperiment monoisotopic mass filtering and refinement" (PE-MMR), consists of several data processing steps: 1) generation of lists of all monoisotopic masses observed in a whole LC/MS experiment, 2) clusterization of monoisotopic masses of a peptide into unique mass classes (UMCs) based on their masses and LC elution times, 3) matching the precursor masses of the MS/MS data to a representative mass of a UMC, and 4) filtration of the MS/MS data based on the presence of corresponding monoisotopic masses and refinement of the precursor ion masses by the UMC mass. PE-MMR increases the throughput of proteomics data analysis, by efficiently removing "garbage" MS/MS data prior to database searching, and improves the mass measurement accuracies (i.e. 0.05 +/- 1.49 ppm for yeast data (from 4.46 +/- 2.81 ppm) and 0.03 +/- 3.41 ppm for glycopeptide data (from 4.8 +/- 7.4 ppm)) for an increased number of identified peptides. In proteomics analyses of glycopeptide-enriched samples, PE-MMR processing greatly reduces the degree of false glycopeptide identification by correctly assigning the monoisotopic masses for the precursor ions prior to database searching. By applying this technique to analyses of proteome samples of varying complexities, we demonstrate herein that PE-MMR is an effective and accurate method for treating massive sets of proteomics data.  相似文献   

8.
Yuan ZF  Liu C  Wang HP  Sun RX  Fu Y  Zhang JF  Wang LH  Chi H  Li Y  Xiu LY  Wang WP  He SM 《Proteomics》2012,12(2):226-235
Determining the monoisotopic peak of a precursor is a first step in interpreting mass spectra, which is basic but non-trivial. The reason is that in the isolation window of a precursor, other peaks interfere with the determination of the monoisotopic peak, leading to wrong mass-to-charge ratio or charge state. Here we propose a method, named pParse, to export the most probable monoisotopic peaks for precursors, including co-eluted precursors. We use the relationship between the position of the highest peak and the mass of the first peak to detect candidate clusters. Then, we extract three features to sort the candidate clusters: (i) the sum of the intensity, (ii) the similarity of the experimental and the theoretical isotopic distribution, and (iii) the similarity of elution profiles. We showed that the recall of pParse, MaxQuant, and BioWorks was 98-98.8%, 0.5-17%, and 1.8-36.5% at the same precision, respectively. About 50% of tandem mass spectra are triggered by multiple precursors which are difficult to identify. Then we design a new scoring function to identify the co-eluted precursors. About 26% of all identified peptides were exclusively from co-eluted peptides. Therefore, accurately determining monoisotopic peaks, including co-eluted precursors, can greatly increase peptide identification rate.  相似文献   

9.
We have explored the utility of gas-phase fractionation by mass spectrometry (MS) in the mass-to-charge (m/z) dimension (GPF(m/z)) for increasing the effective number of protein identifications in cases where sample quantity limits the use of multi-dimensional chromatographic fractionation. A peptide digestate from proteins isolated from the membrane fraction of natural killer (NK) cells was analyzed by microcapillary reversed-phase liquid chromatography coupled online to an ion-trap (IT) mass spectrometer. Performing GPF(m/z) using eight narrow precursor ion scan m/z ranges enabled the identification of 340 NK cell proteins from 12 microg of digestate, representing more than a fivefold increase in the number of proteins identified as compared to the same experiment employing a standard precursor ion survey scan m/z range (i.e., m/z 400-2000). The results show that GPF(m/z) represents an effective technique for increasing protein identifications in global proteomic investigations especially when sample quantity is limited.  相似文献   

10.
蛋白质组学的基础研究之一是蛋白质鉴定.规模化的蛋白质鉴定通常采用"鸟枪法",即选择一些酶切肽段(母离子)碎裂生成二级谱图,通过二级谱图及其母离子质量鉴定肽段,再推断对应的蛋白质.在鉴定过程中,母离子质量是一个关键参数.母离子是否是肽段的单同位素峰决定了正确肽段是否能进入候选,母离子的质量精度决定了候选肽段的数目.本文从判断单同位素峰和系统误差校准这两个角度研究了母离子的准确检测技术.判断单同位素峰的技术在蛋白质上已有研究,包括电荷判断、单同位素峰判断和重叠同位素峰判断.可以借鉴蛋白质水平的技术研究母离子的单同位素峰判断方法.同时母离子的系统误差校准也有较为成熟的方法.这两个角度的研究有助于提高规模化蛋白质的鉴定率.  相似文献   

11.
A rapid and selective liquid chromatographic/tandem mass spectrometric method for determination of fosfomycin was developed and validated. Following protein-precipitation, the analyte and internal standard (fudosteine) were separated from human plasma using an isocratic mobile phase on an Ultimate XB-CN column. An API 4000 tandem mass spectrometer equipped with Turbo IonSpray ionization source was used as detector and was operated in the negative ion mode. Multiple reaction monitoring using the precursor to product ion combinations of m/z 137-->79 and m/z 178-->91 was performed to quantify fosfomycin and fudosteine, respectively. The method was linear in the concentration range of 0.10-12.0 microg/mL using 50 microL of plasma. The lower limit of quantification was 0.10 microg/mL. The intra- and inter-day relative standard deviation over the entire concentration range was less than 10.6%. Accuracy determined at three concentrations (0.25, 1.00 and 8.00 microg/mL for fosfomycin) ranged from -1.0% to -4.2% in terms of relative error. Each plasma sample was chromatographed within 5.0 min. The method was successfully used in a bioequivalence study of fosfomycin in human plasma after an oral administration of capsules containing 1.0 g fosfomycin (approximately 1.3g calcium fosfomycin).  相似文献   

12.
The standard strategy for analysis by tandem mass spectrometry of protein phosphorylation at serine or threonine utilizes the neutral loss of H3PO4 (= 97.977/z) from proteolytic peptide molecular ions as marker fragmentation. Manual control of automatically performed neutral loss-based phosphopeptide identifications is strongly recommended, since these data may contain false-positive results. These are connected to the experimental neutral loss m/z error, to competing peptide fragmentation pathways, to limitations in data interpretation software, and to the general growth of protein sequence databases. The fragmentation-related limitations of the neutral loss approach cover (i) the occurrence of abundant 'close-to-98/z' neutral loss fragmentations, (ii) the erroneous assignment of a neutral loss other than loss of H3PO4 due to charge state mix-up, and (iii) the accidental occurrence of any fragment ion in the m/z windows of interest in combination with a charge-state mix-up. The 'close-to-98/z' losses comprise loss of proline (97.053/z), valine (99.068/z), threonine (101.048/z), or cysteine (103.009/z) preferably from peptides with N-terminal sequences PP, VP, TP, or CP, and loss of 105.025/z from alkylated methionine. Confusion with other neutral losses may occur, when their m/z window coincides with a 98/z window as result of a charge state mix-up. Neutral loss of sulfenic acid from oxidized methionine originating from a doubly charged precursor (63.998/2 = 31.999) may thus mimic the loss of phosphoric acid from a triply charged phosphopeptide (97.977/3 = 32.659). As a consequence of the large complexity of proteomes, peptide sequence ions may occur in one of the mass windows of H3PO4 loss around 97.977/z. Practical examples for false-positive annotations of phosphopeptides are given for the first two groups of error. The majority of these can be readily recognized using the guidelines presented in this study.  相似文献   

13.
Fast atom bombardment (FAB) and collisional activation dissociation (CAD) mass-analysed ion kinetic energy (MIKE) spectra have confirmed the structures of retinyl phosphate (Ret-P), retinyl phosphate mannose (Ret-P-Man) and guanosine 5'-diphospho-D-mannose (GDP-Man). Ret-P-Man was made in vitro while Ret-P and GDP-Man were chemically synthesized. Positive ion FAB mass spectrometry of Ret-P showed an observable short-lived spectrum with a mass ion at m/z 367 [M + H]+, and a major fragment ion at m/z 269 [M + H - H3PO4]+. Negative ion FAB mass spectrometry of Ret-P showed a strong stable spectrum with a parent ion at m/z 365 [M - H]-, a glycerol (G) adduct ion at m/z 457 [M - H + G]- and a dimer ion at m/z 731 [2M - H]-. GDP-Man showed an intense spectrum with parent ion at m/z 604 [M - H]- and cationized species at m/z 626 [M + Na - 2H]- and 648 [M + 2Na - 3H]-. Negative ion FAB mass spectrometry of Ret-P-Man showed a parent ion at m/z 527 [M - H]- and a fragment ion at m/z 259 [C6H12PO9]-. The CAD-MIKE spectra showed structurally significant fragment ions at m/z 442 and 361 for the [M - H]- ion of GDP-Man, and at m/z 509, 406, 364 and 241 for the [M - H]- ion of Ret-P-Man. FAB and CAD-MIKE spectra have been applied successfully to confirm the structure of Ret-P-Man made in vitro from Ret-P and GDP-Man.  相似文献   

14.
A simple, rapid, sensitive and specific liquid chromatography-tandem mass spectrometry method was developed and validated for quantification of metoprolol tartrate (MT) and ramipril, in human plasma. Both the drugs were extracted by liquid-liquid extraction with diethyl ether-dichloromethane (70:30, v/v). The chromatographic separation was performed on a reversed-phase C8 column with a mobile phase of 10 mM ammonium formate-methanol (3:97, v/v). The protonated analyte was quantitated in positive ionization by multiple reaction monitoring with a mass spectrometer. The method was validated over the concentration range of 5-500 ng/ml for metoprolol and ramipril in human plasma. The precursor to product ion transitions of m/z 268.0-103.10 and m/z 417.20-117.20 were used to measure metoprolol and ramipril, respectively.  相似文献   

15.
The potential of drift tube ion mobility (IM) spectrometry in combination with high performance liquid chromatography (LC) and mass spectrometry (MS) for the metabonomic analysis of rat urine is reported. The combined LC-IM-MS approach using quadrupole/time-of-flight mass spectrometry with electrospray ionisation, uses gas-phase analyte characterisation based on both mass-to-charge (m/z) ratio and relative gas-phase mobility (drift time) following LC separation. The technique allowed the acquisition of nested data sets, with mass spectra acquired at regular intervals (65 micros) during each IMS separation (approximately 13 ms) and several IMS spectra acquired during the elution of a single LC peak, without increasing the overall analysis time compared to LC-MS. Preliminary results indicate that spectral quality is improved when using LC-IM-MS, compared to direct injection IM-MS, for which significant ion suppression effects were observed in the electrospray ion source. The use of reversed-phase LC employing fast gradient elution reduced sample preparation to a minimum, whilst maintaining the potential for high throughput analysis. Data mining allowed information on specific analytes to be extracted from the complex metabonomic data set. LC-IM-MS based approaches may have a useful role in metabonomic analyses by introducing an additional discriminatory dimension of ion mobility (drift time).  相似文献   

16.
A rapid and highly sensitive liquid chromatography-tandem mass spectrometric (LC-MS/MS) method for simultaneous determination of cefoperazone sodium and sulbactam sodium in human plasma was developed. The analytes and internal standard (IS), cefuroxime sodium, were extracted from human plasma via liquid-liquid extraction with ethyl acetate and separated on a Waters Xterra C18 column within 3.5 min. Quantitation was performed on a triple quadrupole mass spectrometer employing electrospray ionization technique, operating in selected reaction monitoring (SRM) and negative ion mode. The precursor to product ion transitions monitored for cefoperazone, sulbactam and IS were m/z 644.1→528.0, 232.1→140.0, and 423.0→362.0, respectively. The assay was validated in the linear range of 0.1-20 μg/mL for cefoperazone and 0.02-4 μg/mL for sulbactam. The intra- and inter-day precisions (CV%) were within 8.39% for each analyte. The recoveries were greater than 87.3% for cefoperazone and 87.2% for sulbactam. Each analyte was found to be stable during all sample storage, preparation and analytical procedures. The method was successfully applied in a pharmacokinetic study of Sulperazon injection in six hospital-acquired pneumonia (HAP) patients.  相似文献   

17.
Vitamin K-dependent gamma-glutamyl carboxylase is a 758 amino acid integral membrane glycoprotein that catalyzes the post-translational conversion of certain protein glutamate residues to gamma-carboxyglutamate. Carboxylase has ten cysteine residues, but their form (sulfhydryl or disulfide) is largely unknown. Pudota et al. in Pudota, B. N., Miyagi, M., Hallgren, K. W., West, K. A., Crabb, J. W., Misono, K. S., and Berkner, K. L. (2000) Proc. Natl. Acad. Sci. U. S. A. 97, 13033-13038 reported that Cys-99 and Cys-450 are the carboxylase active site residues. We determined the form of all cysteines in carboxylase using in-gel protease digestion and matrix-assisted laser desorption/ionization mass spectrometry. The spectrum of non-reduced, trypsin-digested carboxylase revealed a peak at m/z 1991.9. Only this peak disappeared in the spectrum of the reduced sample. This peak's m/z is consistent with the mass of peptide 92-100 (Cys-99) disulfide-linked with peptide 446-453 (Cys-450). To confirm its identity, the m/z 1991.9 peak was isolated by a timed ion selector as the precursor ion for further MS analysis. The fragmentation pattern exhibited two groups of triplet ions characteristic of the symmetric and asymmetric cleavage of disulfide-linked tryptic peptides containing Cys-99 and Cys-450. Mutation of either Cys-99 or Cys-450 caused loss of enzymatic activity. We created a carboxylase variant with both C598A and C700A, leaving Cys-450 as the only remaining cysteine residue in the 60-kDa fragment created by limited trypsin digestion. Analysis of this fully active mutant enzyme showed a 30- and the 60-kDa fragment were joined under non-reducing conditions, thus confirming Cys-450 participates in a disulfide bond. Our results indicate that Cys-99 and Cys-450 form the only disulfide bond in carboxylase.  相似文献   

18.
Matrix effects resulting in ion suppression or enhancement have been shown to be a source of variability and inaccuracy in bioanalytical mass spectrometry. Glycerophosphocholines may cause significant matrix ionization effects during quantitative LC/MS/MS analysis and are known to fragment to form characteristic ions (m/z 184) in electrospray mass spectrometry. This ion was used to monitor ion suppression effects in the determination of hydrocodone and pseudoephedrine in human plasma as a means to track and avoid these effects. The m/z 184 ion fragment was detected in both plasma extracts and solutions of phosphatidylcholine. Post-column infusion studies showed that the ion suppression for both drugs and internal standards correlated with the elution of phospholipids. HPLC conditions were adjusted to chromatographically resolve the peaks of interest from the phospholipids. Upon repeated injection, the elution time of the phospholipids decreased while elution of the analyte peaks remained unchanged. This resulted in co-elution and significantly affected peak shape and internal standard response for the analytes. It was decided to use the phospholipid fragment to monitor this matrix effect in validation samples. The resulting method demonstrated intra-day and inter-day precision within 4.5 and 5.6% for hydrocodone and pseudoephedrine, respectively, and accuracy within 8.9 and 8.7% for hydrocodone, and pseudoephedrine, respectively. There was no statistically significant difference in the internal standard response for the determination with and without monitoring the phospholipid fragment ion. We found that monitoring the phospholipid fragment was useful in method development to avoid the matrix effects, and in routine analysis to provide a practical way to ensure the avoidance of matrix effects in each individual sample.  相似文献   

19.
A gas chromatographic mass spectrometric assay for clonidine in plasma with a detection limit of a few picograms per ml was required. The p-trifluoromethylbenzyl, pentafluorobenzyl and pentafluorobenzoyl derivatives of clonidine were synthesized and the electron capture negative ion chemical ionization mass spectra of these compounds show extensive fragmentation with prominent ions at m/z 35 and 37 due to the two chlorine atoms in the clonidine molecule. Selected ion monitoring of specific high mass ions in these mass spectra indicated that the required sensitivity could not be obtained with these derivatives. Several bis(trifluoromethyl)pyrimidines were synthesized and these compounds were found to give an intense negative ion current under conditions of resonance electron capture. Consequently, a derivative of clonidine containing a bis(trifluoromethyl)aryl group was synthesized by reacting the drug with 3,5-bis(trifluoromethyl)benzoyl chloride. The negative ion mass spectrum of the reaction product has a base peak at m/z 673 and, when this ion is specifically monitored, an amount of derivative equivalent to 1 picogram of clonidine can be detected. This allowed the development of an assay for clonidine in plasma with a precision of 8% (SD) at 50 pg ml-1, 22% (SD) at 20 pg ml-1 and a lower limit for quantitative determination of 10 pg ml-1. Plasma concentrations of clonidine in 10 subjects given a single 50 micrograms oral dose are reported.  相似文献   

20.
A selective and sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) assay for the determination of cycloserine in human plasma is developed using niacin as internal standard (IS). The analyte and IS were extracted from 500 μL of human plasma via solid phase extraction on Waters Oasis MCX cartridges. Chromatographic separation was achieved on a Peerless Basic C18 (100 mm × 4.6mm, 3 μm) column under isocratic conditions. Detection of analyte and IS was done by tandem mass spectrometry, operating in positive ion and multiple reaction monitoring (MRM) acquisition mode. The protonated precursor to product ion transitions monitored for cycloserine and niacin were at m/z 103.1 → 75.0 and 124.1 → 80.1 respectively. The method was fully validated for its selectivity, interference check, sensitivity, carryover check, linearity, precision and accuracy, reinjection reproducibility, recovery, matrix effect, ion suppression/enhancement, stability and dilution integrity. The limit of detection (LOD) and lower limit of quantitation of the method were 0.0013 and 0.20 μg/mL respectively with a linear dynamic range of 0.20-30.00 μg/mL for cycloserine. The intra-batch and inter-batch precision (%CV) across six quality control levels was less than 8.0% for cycloserine. The method was successfully applied to a bioequivalence study of 250 mg cycloserine capsule formulation in 24 healthy Indian male subjects under fasting condition.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号