首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Li G  Liao JM  Hu GQ  Ma NZ  Wu PJ 《Biosensors & bioelectronics》2005,20(10):2140-2144
A carbon nanotube modified biosensor for monitoring total cholesterol in blood was studied. This sensor consists of a carbon working electrode and a reference electrode screen-printed on a polycarbonate substrate. Cholesterol esterase, cholesterol oxidase, peroxidase and potassium ferrocyanide were immobilized on the screen-printed carbon electrodes. Multi-walled carbon nanotubes (MWCN) were added to prompt electron transfer. Experimental results show that the carbon nanotube modified biosensor offers a reliable calibration profile and stable electrochemical properties.  相似文献   

2.
Fu Y  Chen Q  Zhou J  Han Q  Wang Y 《Analytical biochemistry》2012,421(1):103-107
A new chiral biosensor has been fabricated by immobilizing γ-globulin on gold nanoparticles modified glassy carbon electrodes, which could recognize and detect mandelic acid (MA) enantiomers. Differential pulse voltammetry, quartz crystal microbalance, ultraviolet-visible spectroscopy, and atomic force microscopy were used to characterize the enantioselectivity. The results exhibited that γ-globulin modified electrode could enantioselectively recognize MA enantiomers, and larger response signals were obtained from R-MA. The factors influencing the performance of the resulting biosensor were investigated. The enantiomeric composition of R- and S-MA enantiomer mixtures could be determined by measuring the current responses of the sample. The developed electrodes have the advantages of simple preparation, good stability, and rapid detection.  相似文献   

3.
This work describes the development of an automated flow-based biosensor that employs genetically modified acetylcholinesterase (AChE) enzymes B394, B4 and wild type B131. The biosensor was based on a screen printed carbon electrode (SPE) that was integrated into a flow cell. Enzymes were immobilised on cobalt (II) phthalocyanine (CoPC) modified electrodes by entrapment in a photocrosslinkable polymer (PVA-AWP). The automated flow-based biosensor was successfully used to quantify three organophosphate pesticides (OPs) in milk samples. The OPs used were chlorpyriphos-oxon (CPO), ethyl paraoxon (EPOx) and malaoxon (MOx). The total analysis time for the assay was less than 15 min. Initially, the biosensor performance was tested in phosphate buffer solution (PBS) using B394, B131 and B4 biosensors. The best detection limits were obtained with B394; therefore, this biosensor was used to produce calibration data in milk with three OPs in the concentration range of 5 × 10(-6)M to 5 × 10(-12)M. The limit of detection (LOD) obtained in milk for CPO, EPOx and MOx were 5 × 10(-12)M, 5 × 10(-9)M and 5 × 10(-10)M, respectively, with a correlation coefficient R(2)=0.9910. The automated flow-based biosensor successfully quantified the OPs in different fat-containing milk samples. There were no false positives or false negatives observed for the analytical figures of merit for the constructed biosensors. This method is inexpensive, sensitive, portable, non-invasive and provides real-time results. This analytical system can provide rapid detection of highly toxic OPs in food matrices such as milk.  相似文献   

4.
A novel detection system for the determination of glucose in the presence of clinically important interferents, based on the use of dual sensors and flow-injection analysis (FIA), is described. The normalisation methodology involves measurement of the interference signal at a reference sensor; this signal can then be subtracted from the glucose sensor signal (post-run) to give a corrected measurement of the glucose concentration. The detection system consists of a thin layer cell with dual glassy carbon working electrodes. One electrode was surface modified to act asglucose biosensor by immobilisation of glucose oxidase (GOx) (from Aspergillus niger) with 1% glutaraldehyde and bovine serum albumin. The second electrode (glucose oxidase omitted) was utilised to measure the interference signal responding only to electroactive species present in the injected sample. A computer controlled multichannel potentiostat was used for potential application and current monitoring duties. The sensor responses were saved in ASCII format to facilitate post-run analysis in Microsoft Excel. Cyclic voltammetry (CV) was utilised to investigate the manner in which the interference signal contributed to the total signal obtained at the biosensor in the presence of glucose. The kinetic parameters Imax and the apparent Michaelis-Menten constant, K′m, were calculated for the sensor operating under flow-injection conditions.  相似文献   

5.
The long-term stability of sensing interfaces is an important issue in biosensor fabrication. A novel stable gold nanoparticle (AuNP)-modified glassy carbon (GC) electrode interface (GC-Ph-AuNP)-based biosensor for detecting carcinoembryonic antigen (CEA) was developed. GC electrodes were modified with 1,4-phenylenediamine to form a stable layer, and then AuNPs were bound onto the GC electrodes through CAu bonds. Anti-CEA was directly adsorbed on AuNPs fixed on the GC electrode. The linear range of the immunosensor was from 10 fg to 100 ng mL(-1) with a detection limit of 3 fg mL(-1) (S/N=3). The current of the immunosensor was increased by 4% after one month. The GC-Ph-AuNP immunosensor showed high sensitivity, a wide linear range, low detection limit, and good selectivity and stability. The immobilization method of the immunosensor could be widely applied to construct other immunosensors.  相似文献   

6.
The dry and wet stability of Drosophila acetylcholinesterase non-covalently immobilized onto polyethyleneimine modified screen-printed carbon electrodes was improved when compared to non-immobilized acetylcholinesterase, and acetylcholinesterase covalently immobilized onto dialdehyde and polyethyleneimine modified electrodes. Stabilizer mixtures were characterized for additional stabilization of acetylcholinesterase during storage in the dry state, with dextran-sulphate/sucrose and polygalacturonic acid/sucrose mixtures proving highly effective for long-term storage of biosensor electrodes.  相似文献   

7.
A novel amperometric biosensor, based on electrodeposition of platinum nanoparticles onto multi-walled carbon nanotube (MWNTs) and immobilizing enzyme with chitosan-SiO(2) sol-gel, is presented in this article. MWNTs were cast on the glass carbon (GC) substrate directly. An extra Nafion coating was used to eliminate common interferents such as acetaminophen and ascorbic acids. The morphologies and electrochemical performance of the modified electrodes have been investigated by scanning electron microscopy (SEM) and amperometric methods, respectively. The synergistic action of Pt and MWNTs and the biocompatibility of chitosan-SiO(2) sol-gel made the biosensor have excellent electrocatalytic activity and high stability. The resulting biosensor exhibits good response performance to glucose with a wide linear range from 1 microM to 23 mM and a low detection limit 1 microM. The biosensor also shows a short response time (within 5s), and a high sensitivity (58.9 microAm M(-1)cm(-2)). In addition, effects of pH value, applied potential, rotating rate, electrode construction and electroactive interferents on the amperometric response of the sensor were investigated and discussed in detail.  相似文献   

8.
We report a novel electrochemical biosensor for direct discrimination of d- and l-mandelic acid (d- and l-MA) in aqueous medium. The glassy carbon electrode (GCE) surface was modified with reduced graphene oxide (rGO) and γ-globulin (GLOB). Electrochemical characterization of the modified electrodes was investigated by cyclic voltammetry and electrochemical impedance spectroscopy. The modified electrode surfaces were also characterized by scanning electron microscopy. Electrochemical response of the prepared electrode (GCE/rGO/GLOB) for discrimination of d- and l-MA enantiomers was investigated by cyclic voltammetry and was compared with bare GCE in the concentration range of 2 to 10 mM. Whereas the bare GCE showed no electrochemical response for the MA enantiomers, the GCE/rGO/GLOB electrode exhibited direct and selective discrimination with different oxidation potential values of 1.47 and 1.71 V and weak reduction peaks at potential values of −1.37 and −1.48 V, respectively. In addition, electrochemical performance of the modified electrode was investigated in mixed solution of d- and l-MA. The results show that the produced electrode can be used as electrochemical chiral biosensor for MA.  相似文献   

9.
《IRBM》2008,29(2-3):202-207
This paper deals with the development of a disposable electrochemical sensor for the detection of hydrogen peroxide, using screen-printed carbon-based electrodes (SPCEs) modified with multi-wall carbon nanotubes (MWCNs) dispersed in a polyethylenimine (PEI) mixture. The modified sensors showed an excellent electrocatalytic activity towards the analyte, respect to the high overvoltage characterising unmodified screen-printed sensors. The composition of the PEI/MWCNT dispersion was optimised in order to improve the sensitivity and reproducibility. The optimised sensor showed good reproducibility (10% RSD calculated on three experiments repeated on the same electrode), whereas a reproducibility of 15% as RSD was calculated on electrodes from different preparations. Preliminary experiments carried out using glucose oxidase (GOD) as biorecognition element gave rise to promising results indicating that these new devices may represent interesting components for biosensor construction.  相似文献   

10.
In this article, we describe a third-generation amperometric glucose biosensor working under physiological conditions. This glucose biosensor consists of a recently discovered cellobiose dehydrogenase from the ascomycete Corynascus thermophilus (CtCDH) immobilized on different commercially available screen-printed electrodes made of carbon (SPCEs), carboxyl-functionalized single-walled carbon nanotubes (SPCE-SWCNTs), or multiwalled carbon nanotubes (SPCE-MWCNTs) by simple physical adsorption or a combination of adsorption followed by cross-linking using poly(ethyleneglycol) (400) diglycidyl ether (PEGDGE) or glutaraldehyde (GA). The CtCDH-based third-generation glucose biosensor has a linear range between 0.025 and 30 mM and a detection limit of 10 μM glucose. Biosensors based on SWCNTs showed a higher sensitivity and catalytic response than the ones functionalized with MWCNTs and the SPCEs. A drastic increase in response was observed for all three electrodes when the adsorbed enzyme was cross-linked with PEGDGE or GA. The operational stability of the biosensor was tested for 7 h by repeated injections of 50 mM glucose, and only a slight decrease in the electrochemical response was found. The selectivity of the CtCDH-based biosensor was tested on other potentially interfering carbohydrates such as mannose, galactose, sucrose, and fucose that might be present in blood. No significant analytical response from any of these compounds was observed.  相似文献   

11.
In this article, gold nanostructure modified electrodes were achieved by a simple one-step electrodeposition method. The morphologies of modified electrodes could be easily controlled by changing the pH of HAuCl4 solution. The novel nanoflower-like particles with the nanoplates as the building blocks could be interestingly obtained at pH 5.0. The gold nanoflower modified electrodes were then used for the fabrication of electrochemical DNA biosensor. The DNA biosensor fabrication process was characterized by cyclic voltammetry and electrochemical impedance spectroscopy with the use of ferricyanide as an electrochemical redox indicator. The DNA immobilization and hybridization on gold nanoflower modified electrode was studied with the use of [Ru(NH3)6]3+ as a hybridization indicator. The electrochemical DNA biosensor shows a good selectivity and sensitivity toward the detection of target DNA. A detection limit of 1 pM toward target DNA could be obtained.  相似文献   

12.
Disposable hydrogen peroxide biosensor was developed based on the direct electron transfer of horseradish peroxidase (HRP) on porous screen-printed carbon electrodes. Conventional screen-printing process was manually performed to fabricate the planar carbon electrodes, which were endowed with porous surfaces especially after anodizing pretreatment. The cyclic voltammetry experiment indicated a pair of stable and well-defined redox peaks with a formal potential of -0.33 V. And the formal potential was pH-dependent, having a slope of -55.2 mV/pH which indicated one electron transfer. The heterogeneous electron transfer rate constant k(s) was estimated to be 13.28+/-4.80s(-1). Additionally, the sensitivity was 143.3 mAM(-1)cm(-2) and the linear range was from 5.98 to 35.36 microM. In conclusion, the present work achieved the direct electron transfer of HRP on screen-printed electrodes without any promoters. The porous structure of screen-printed carbon electrodes facilitated the direct electron transfer between the active sites of HRP and the electrodes due to large amounts of conductive sites available on the surface for contacting with enzyme molecules. Moreover, the proposed biosensor could be mass-produced at low price, promising for commercial application.  相似文献   

13.
A ferricyanide mediated microbial biosensor for ethanol detection was prepared by surface modification of a glassy carbon electrode. The selectivity of the whole Gluconobacter oxydans cell biosensor for ethanol determination was greatly enhanced by the size exclusion effect of a cellulose acetate (CA) membrane. The use of a CA membrane increased the ethanol to glucose sensitivity ratio by a factor of 58.2 and even the ethanol to glycerol sensitivity ratio by a factor of 7.5 compared with the use of a dialysis membrane. The biosensor provides rapid and sensitive detection of ethanol with a limit of detection of 0.85 microM (S/N=3). The selectivity of the biosensor toward alcohols was better compared to previously published enzyme biosensors based on alcohol oxidase or alcohol dehydrogenases. The biosensor was successfully used in an off-line monitoring of ethanol during batch fermentation by immobilized Saccharomyces cerevisiae cells with an initial glucose concentration of 200 g l(-1).  相似文献   

14.
A new amperometric whole cell biosensor based on Saccharomyces cerevisiae immobilized in gelatin was developed for selective determination of vitamin B1 (thiamine). The biosensor was constructed by using gelatin and crosslinking agent glutaraldehyde to immobilize S. cerevisiae cells on the Teflon membrane of dissolved oxygen (DO) probe used as the basic electrode system combined with a digital oxygen meter. The cells were induced by vitamin B1 in the culture medium, and the cells used it as a carbon source in the absence of glucose. So, when the vitamin B1 solution is injected into the whole cell biosensor system, an increase in respiration activity of the cells results from the metabolic activity and causes a decrease in the DO concentration of interval surface of DO probe related to vitamin B1 concentration. The response time of the biosensor is 3 min, and the optimal working conditions of the biosensor were carried out as pH 7.0, 50mM Tris-HCl, and 30 degrees C. A linear relationship was obtained between the DO concentration decrease and vitamin B1 concentration between 5.0 x 10(-3) and 10(-1) microM. In the application studies of the biosensor, sensitive determination of vitamin B1 in the vitamin tablets was investigated.  相似文献   

15.
The direct electrochemistry of horseradish peroxidase (HRP) on a novel sensing platform modified glassy carbon electrode (GCE) has been achieved. This sensing platform consists of Nafion, hydrophilic room-temperature ionic liquid (RTIL) and Au nanoparticles dotted titanate nanotubes (GNPs-TNTs). The composite of RTIL and GNPs-TNTs was immobilized on the electrode surface through the gelation of a small amount of HRP aqueous solution. The composite was characterized by transmission electron microscopy (TEM), powder X-ray diffraction (XRD) and infrared spectroscopy (IR). UV-Vis and IR spectroscopy demonstrated that HRP in the composite could retain its native secondary structure and biochemical activity. The HRP-immobilized electrode was investigated by cyclic voltammetry and chronoamperometry. The results from both techniques showed that the direct electron transfer between the nanocomposite modified electrodes and heme in HRP could be realized. The biosensor responded to H(2)O(2) in the linear range from 5×10(-6) to 1×10(-3) mol L(-1) with a detection limit of 2.1×10(-6) mol L(-1) (based on the S/N=3).  相似文献   

16.
We developed an electrochemical glycated hemoglobin (HbA(1c)) biosensor for diagnosing diabetes in whole human blood based on the competitive binding reaction of glycated proteins. Until now, no studies have reported a simple and accurate electrochemical biosensor for the quantification of HbA(1c) in whole blood. This is because it is very difficult to correctly distinguish HbA(1c) from large amounts of hemoglobin and other components in whole blood. To detect glycated hemoglobin, we used electrodes modified with boronic acid, which forms a covalent bond between its diol group and the cis-diol group of the carbohydrate moiety of glycated proteins. For accurate HbA(1c) biosensing, we first removed blood components (except for hemoglobin) such as glycated proteins and blood glucose as they interfere with the boronate-based HbA(1c) competition analysis by reacting with the boronate-modified surface via a cis-diol interaction. After hemoglobin separation, target HbA(1c) and GOx at a predetermined concentration were reacted through a competition onto the boronate-modified electrode, allowing HbA(1c) to be detected linearly within a range of 4.5-15% of the separated hemoglobin sample (HbA(1c)/total hemoglobin). This range covers the required clinical reference range of diabetes mellitus. Hence, the proposed method can be used for measuring %HbA(1c) in whole human blood, and can also be applied to measuring the concentration of various glycated proteins that contain peripheral sugar groups.  相似文献   

17.
Erythrocytes (red blood cells) are a major source of response variation in biosensor electrodes expected to operate in whole blood. Such a blood-to-plasma difference (hematocrit effect) must be minimized for those sensors directed towards the hospital market where wide variations in hematocrit can be seen. Typically, many current glucose sensors demonstrate a decreasing response to the analyte in the presence of increasing hematocrit levels. A sensor electrode for glucose is described which displays a reduced sensitivity to changes in hematocrit. The working electrode comprises a base porous conducting carbon layer, which is impregnated with a mixture including glucose oxidase and a ferrocene redox mediator. The base carbon layer has a void volume of 50%, an average pore diameter of less than 0.1 microm and a thickness of about 20 microm. The interior void volume of the base carbon layer is filled entirely with a substantial proportion of the impregnating mixture such that very little remains on the exterior. The resulting impregnated porous electrode excludes erythrocytes and is consequently capable of operating acceptably in venous, capillary, arterial and neonatal blood over a wide hematocrit range of 20-70%.  相似文献   

18.
Nanographene-based tyrosinase biosensor for rapid detection of bisphenol A   总被引:1,自引:0,他引:1  
Hydrophilic nanographene (NGP) prepared by ball milling of graphite was used as the support to construct a novel tyrosinase biosensor for determination of bisphenol A (BPA). The performances of the nanographene-based tyrosinase biosensor were systematically compared with those of multiwall carbon nanotubes (MWNTs) modified tyrosinase biosensors. The results indicated that the nanographene-based tyrosinase biosensor provided significant advantages over MWNTs-based tyrosinase biosensor in term of response, repeatability, background current and limit of detection (LOD), which could be attributed to its larger specific surface area and unique hierarchical tyrosinase-NGP nanostructures. The nanographene-based tyrosinase biosensor displayed superior analytical performance over a linear range from 100 nmol L(-1) to 2000 nmol L(-1), with LOD of 33 nmol L(-1) and sensitivity of 3108.4 mA cm(-2)M(-1). The biosensor was further used for detecting BPA (leaching from different vessels) in tap water, and the accuracy of the results was validated by high performance liquid chromatography (HPLC). The nanographene-based tyrosinase biosensor proved to be a promising and reliable tool for rapid detection of BPA leached from polycarbonate plastic products and for on-site rapid analysis of emergency pollution affairs of BPA.  相似文献   

19.
In this paper, a new glucose biosensor was prepared. At first, Prussian blue (PB) was electrodeposited on a glassy carbon electrode (GCE) modified by titanium dioxide-multiwall carbon nanotubes-chitosan (TiO2-MWNTs-CS) composite, and then gold nanoparticles functionalized by poly(diallyldimethylammonium chloride) (PDDA-Au) were adsorbed on the PB film. Finally, the negatively charged glucose oxidase (GOD) was self-assembled on to the positively charged PDDA-Au. The electrochemical performances of the modified electrodes had been studied by cyclic voltammetry (CV) and amperometric methods, respectively. In addition, the stepwise fabrication process of the as-prepared biosensor was characterized by scanning electron microscopy. PDDA-Au nanoparticles were characterized by ultraviolet–vis absorption spectroscopy and transmission electron microscopy. Under the optimal conditions, the as-prepared biosensor exhibited a good response performance to glucose with a linear range from 6 μM to 1.2 mM with a detection limit of 0.1 μM glucose (S/N = 3). In addition, this work indicated that TiO2-MWNTs-CS composite and PDDA-Au nanoparticles held great potential for constructing biosensors.  相似文献   

20.
Gold nanoshells (GNSs) were self-assembled on the surface of transparent glasses modified with 3-aminopropyltrimethoxysilane (APTES) to form GNS self-assembled monolayers (SAMs). Because the localized surface plasmon resonance (LSPR) of GNSs can be controlled in the near-infrared (NIR) region of the spectrum, where the optical transmission through tissue and whole blood is optimal, GNSs would be used as an effective signal transduction in whole blood. Accordingly, after modified with cystamine and biotin-NHS (N-hydroxy succinimide), GNS SAMs were used as a novel optical biosensor for real-time detection of streptavidin-biotin interactions in diluted human whole blood within short assay time, without any sample purification/separation. An UV-vis-NIR spectrophotometer was used to monitor the absorbance changes at 730 nm as a function of time for different concentrations of streptavidin in 20% whole blood, and the results showed that the biosensor displayed low detection limit of approximately 3 microg/mL and wide dynamic range of approximately 3-50 microg/mL. This approach provides an opportunity to construct LSPR biosensor for protein sensing and cellular analysis in diluted whole blood.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏