首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
This review presents recent developments in high-performance liquid chromatographic (HPLC) analysis of corticosteroids for the determination of clinically important steroids in biological specimens. Various sample preparation techniques are described.  相似文献   

2.
The basic principle of derivatization of a hydrazide moiety with an aldehyde as applied in the method developed by Lacroix et al. [J. Chromatogr., 307 (1984) 137–144] for the quantitation of isoniazid and acetylisoniazid was imppoved by modification, standardization and extension to allow quantitation of hydrazine in patient samples. It could be shown that 40 μl of 1% methanonic cinnamaldehyde per 200 μl of deproteinized analysate gave maximal chromophoric isoniazid-cinnamaldehyde conjugate, read at 340 nm. The hydrolytic loss of isoniazid, crucial to the quantitation of acetylisoniazid, could be compensated for by introduction of an appropriate set of calibration curves. Although the method described here allows quantitation of monoacetylhydrazie and diacetylhydrazine, in addition to hydrazine, in mono-spiked samples, the method cannot be used for the quantitation of the acetylated metabolites of hydrazine in patient samples because of a lack of specificity. Linear calibration curves in the range 1–25 μg/ml for isoniazid and acetylisoniazid, 10–400 ng/ml for hydrazine and 50–1000 ng/ml for mono-acetylhydrazine and diacetylhydrazine, could be constructed; analyte recoveries approaching 100% could be achieved in all instances.  相似文献   

3.
4.
This report describes the development of an HPLC-UV method for studies of glycoamines and glycoamine-like compounds in normal human serum and osteosarcoma patient serum as potential biological markers of cancer. The glycoamines, a newly recognized class of endogenous, low-molecular-mass biopolymers, are conjugates of amino acids and sugar units, containing 5 to 29 amino acid and 1 to 17 sugar units. After ultrafiltration of serum samples, reversed-phase HPLC separation with diode-array detection was used to obtain standard profiles of serum ultrafiltrates below Mr 10 000 in healthy subjects. These highly reproducible profiles utilized two-dimensional peak identification and were used to develop a statistical profile of the major glycoamine peaks in normal serum. This newly developed analytical method was subsequently used to address a key question: whether or not there is a single tumor-specific glycoamine or a family of tumor-specific glycoamines in cancer patient serum. Preliminary results suggest that this method can separate and detect glycoamines and glycoamine-like compounds in various types of cancer patient serum with a high degree of reproducibility on the basis of comparative two-dimensional identification of natural compounds and a panel of synthetic glycoamine analogs. Moreover, the method is useful for following the relative changes in the amount of a given glycoamine over an extended clinical time course. Initial results suggest that a glycoamine or glycoamine-like compound, GA-4.63, may have clinical utility in human osteosarcoma studies.  相似文献   

5.
A significantly improved method for base composition analysis of synthetic oligodeoxyribonucleotides is presented. This highly accurate and sensitive method used enzymatic digestion followed by high-resolution HPLC of the nucleosides to determine the empirical base composition of the parent compound. The enzymatic digestion reaction is quantitative and is not blocked by modified bases, thus allowing the degree of base deprotection and chemical modification to be assessed. Digestion data are presented for oligodeoxyribonucleotides which range from 18 to 150 bases in length with excellent agreement of experimental and theoretical composition. The method is also applicable to high-molecular-weight genomic DNA.  相似文献   

6.
7.
Separation of inositol phosphates by low-pressure anion-exchange chromatography yields unsatisfactory results, while previously described anion-exchange HPLC methods require such extensive processing times that they preclude efficient sample analysis. Using a low-capacity Vydac nucleotide anion-exchange column, we have developed a method which allows complete separation of myo-inositol, inositol 1-phosphate, inositol 1,4-bisphosphate, inositol 1,4,5-trisphosphate, and inositol 1,3,4,5-tetrakisphosphate in approximately 10 min followed by a 5-min column regeneration time. This method provided exceptional reproducibility and quantitative recovery of each inositol phosphate. One column was used for over 300 separations with no loss in performance or alteration in elution pattern. A modified procedure with a 14-min gradient was developed to separate the 1,3,4- and 1,4,5-isomers of inositol trisphosphate. These separation procedures were used to characterize the kinetics of degradation of inositol phosphates by lysates of erythrocytes and neutrophils. We conclude that these procedures are applicable for rapid and quantitative analysis of radiolabeled inositol phosphates in cellular extracts.  相似文献   

8.
The N-feruloylserotonin containing fraction was isolated from seeds of Leuzea carthamoides (Willd.) DC by solvent extraction followed by column chromatography on silica gel or on Sephadex LH-20. Nuclear magnetic resonance spectroscopic analysis of the isolated fraction showed the presence of four structurally related compounds. These compounds were identified as four isomers of N-feruloylserotonin: N-(Z)-feruloylserotonin, N-(Z)-isoferuloylserotonin, N-(E)-feruloylserotonin and N-(E)-isoferuloylserotonin. They were analyzed by HPLC on Separon SGX C18, Separon SGX and Separon SGX phenyl, using various mobile phases. Separon SGX phenyl phase was found the most efficient for a rapid analysis and for the final separation of the N-feruloylserotonin isomers.  相似文献   

9.
A high-performance liquid chromatographic method has been developed for the determination of nitroxoline in 50-μl plasma and urine samples.A structural analogue of nitroxoline, 8-hydroxyquinoline, was added to the eluent in order to suppress peak asymmetry. Several parameters of the eluent were studied for the optimisation of the chromatographic system.Plasma concentration—time curves were constructed for three volunteers after they had received an oral dose of 100 mg of nitroxoline. Plasma half-life was about 1 h. Within 12 h, about 1% of the dose was excreted in the urine as free nitroxoline and about 30% as conjugated metabolite of the parent compound.  相似文献   

10.
11.
12.
A method for the quantitative determination of ammonium in human urine by high-performance liquid chromatography (HPLC) is described. After making fluorescent substances with fluorescamine, they were separated and quantified by their fluorometric intensity. The intensity (as measured by peak height) was linear between 0.5 and 5.0 micrograms, and coefficients of variation for elution time and peak height on replicate analysis of the standard were 0.15 and 4.2%, respectively. Recoveries of added ammonium were 96.5 and 97.3%, respectively, on 2.0 and 3.0 micrograms by this method. Detection limit of this method was 0.2 microgram. There was good agreement between the proposed HPLC method (X) and ion chromatographic method (Y), giving the relationships as Y = 0.956X + 0.012, r = 0.991.  相似文献   

13.
A sensitive HPLC method has been developed for monitoring fucoganglioside hydrolysis by purified alpha-L-fucosidase. The high-resolution method employs a Lichrosorb-NH2 column, a 10-min isocratic elution with potassium phosphate/acetonitrile buffer, detection of ganglioside products with a uv monitor at 195 nm, and quantification of low picomolar amounts of these gangliosides with an integrator. The usefulness of the HPLC method has been exemplified by using it to demonstrate the hydrolysis of gangliosides fucosyl-GM1 and fucosyl-GD1b by purified human liver alpha-L-fucosidase in the absence of activator proteins and/or detergents.  相似文献   

14.
15.
16.
Demethylmenaquinone and menaquinone mixtures from some species of enterobacteria were analysed by reverse-phase partition high-performance liquid chromatography. This method allowed clear separation and quantitative determination of these quinone components.  相似文献   

17.
A sensitive, selective, and rapid high-performance liquid chromatographic procedure was developed for the determination of isoxicam in human plasma and urine. Acidified plasma or urine were extracted with toluene. Portions of the organic extract were evaporated to dryness, the residue dissolved in tetrahydrofuran (plasma) or acetonitrile (urine) and chromatographed on a μBondapak C18 column preceded by a 4–5 cm × 2 mm I.D. column packed with Corasil C18. Quantitation was obtained by UV spectrometry at 320 nm. Linearity in plasma ranged from 0.2 to 10 μg/ml. Recoveries from plasma samples seeded with 1.8, 4 and 8 μg/ml isoxicam were 1.86 ± 0.077, 4.10 ± 0.107 and 8.43 ± 0.154 μg/ml with relative standard deviations of 3.3%, 2.5% and 5.4%, respectively. The linearity in urine ranged from 0.125 to 2 μg/ml. The precision of the method was 3.3–9.0% relative standard deviation over the linear range.  相似文献   

18.
19.
The objective of the study was to develop a sensitive and specific assay for studying the pharmacokinetics of a novel calcium antagonist, a benzimidazolyl-substituted tetraline derivative, mibefradil (I) in the dog. The assay involves liquid-liquid extraction of a biological sample, reversed-phase HPLC separation and fluorescence detection (λex = 270 nm and λem = 300 nm) of a sample components. Each sample was eluted with a mobile phase pumping at a flow-rate of 2 ml/min. The mobile phase composition was a mixture of acetonitrile and aqueous solution (38:62, v/v). The aqueous solution contains 0.0393 M KH2PO4 and 0.0082 M Na-pentanesulphonic acid. The retention times were 10.7 min for I, and 12.2 min for internal standard Ro 40–6792. Calibration curves with concentrations of I ranging from 10 to 500 ng/ml were linear (r2 > 0.99). The detection limit for I was 0.5 ng/ml when 0.5 ml of plasma or urine was used. Intra- and inter-day accuracy and precision were within 10%. The assay was successfully applied to the pharmacokinetic studies of I in dogs.  相似文献   

20.
The technique of 32P postlabeling of DNA-carcinogen adducts is a useful and extremely sensitive method of detecting and quantitating DNA damage by carcinogens. We have adapted the 32P method to analysis by high-pressure liquid chromatography, making the procedure more rapid and convenient than when thin-layer chromatography is used. Following DNA isolation and hydrolysis, nucleotide-carcinogen adducts are enhanced relative to normal nucleotides by solvent extraction and then labeled with high-specific-activity [gamma-32P]ATP. The resulting 32P-postlabeled nucleotides are resolved by reverse-phase ion-pair HPLC. After as little as 3 h of exposure to carcinogens, DNA adducts can be demonstrated from 1 microgram or less of mouse hepatic DNA. Acetylated and nonacetylated adducts can be resolved from hepatic DNA of mice treated with 2-aminofluorene. Differences in DNA damage as measured by adduct formation were demonstrated between "rapid" and "slow" acetylator mouse strains. Rapid-acetylator C57BL/6J mice had three times the amount of hepatic DNA adducts as slow-acetylator A/J mice 3 h after a 60 mg/kg dose of 2-aminofluorene. 4-Aminobiphenyl and 2-naphthylamine each showed an adduct peak with retention time similar to that of the nonacetylated 2-aminofluorene adduct, while benzidine gave a major adduct that eluted somewhat earlier as would be expected for an acetylated adduct. The alkenylbenzenes, safrole and methyleugenol, also formed DNA adducts detectable by this method. DNA prepared from skin of mice painted with benzo[a]pyrene also contained carcinogen-DNA adducts detectable and resolvable by HPLC analysis following 32P postlabeling. The combination of HPLC with 32P postlabeling appears to be a useful technique for the rapid detection and quantitation of DNA damage caused by several classes of aromatic carcinogens.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号