首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
BACKGROUND: We report successful treatment of a patient 6 years after ascending aorta and aortic valve replacement suffering from a combination of two pseudoaneurysms. The first of them originated from the coronary ostial suture line and the second pseudoaneurysm originated from the distal suture line. METHODS: We performed re-replantation of the left main trunk to the prosthesis and then we resected the pseudoaneurysm originating from the distal suture line and we replaced the entire aorta by a vascular graft. RESULTS: The postoperative convalescence was uneventful, the patient was discharged two weeks after the surgery. The patient is currently in a very good condition one year after the surgery. CONCLUSIONS: Coronary ostial pseudoaneurysm in patients after ascending aorta and aortic valve replacement with the use of "button technique" is a quite rare situation. The combination of two pseudoaneurysms originating from different suture lines in one patient seems to be unique in literature reviews.  相似文献   

2.
To explore reasons for a high accumulation of Ca and P occurring in the coronary artery of Thai with aging, the authors investigated age-related changes of elements in the coronary artery, ascending aorta near the heart, and cardiac valves in single individuals, and the relationships in the elements between the coronary artery and either the ascending aorta or cardiac valves. After an ordinary dissection by medical students at Chiang Mai University was finished, the anterior descending arteries of the left coronary artery, ascending aortas, mitral valves, and aortic valves were resected from the subjects. The subjects consisted of 17 men and 9 women, ranging in age from 46 to 76 yr. The element content was analyzed by inductively coupled plasma-atomic emission spectrometry. The average content of Ca and P was the highest in the coronary artery and decreased in the order aortic valve, ascending aorta, and mitral valve. The Ca, P, and Mg content increased in the coronary artery in the fifties and in the ascending aorta, aortic valve, and mitral valve in the sixties. It should be noted that the accumulation of Ca, P, and Mg occurred earlier in the coronary artery than in the ascending aorta, aortic valve, and mitral valve. It was found that with respect to the Ca, P, Mg, and Na contents, the coronary artery correlated well with both the aortic valve and ascending aorta, especially with the aortic valve, but it did not correlate with the mitral valves. This finding suggests that the accumulation of Ca, P, Mg, and Na occurs in the coronary artery together with the aortic valve and ascending aorta, but not together with the mitral valve. Because regarding the accumulation of Ca, P, and Mg, the ascending aorta and aortic valve are preceded by the coronary artery, it is unlikely that the accumulation of Ca, P, and Mg spreads from the ascending aorta or aortic valve to the coronary artery.  相似文献   

3.
During 1978, 42 consecutive patients underwent simultaneous aortic valve and ascending aorta replacement in our institution. Seventy-one percent were at low risk despite a high incidence of dissection. Twenty-nine percent were high-risk patients requiring repeat or concomitant cardiac procedures, mostly on an emergency basis. Depending upon the extent of the disease at the aortic root, either of two surgical approaches was used: (1) conventional aortic valve and supracoronary ascending aorta replacement, with or without right coronary artery ostium reimplantation, or (2) insertion of a composite graft containing an aortic valve prosthesis, with reconstruction of both coronary arteries. Preservation of coronary ostia was possible in 85% of the patients, and composite grafts were used in 15%. The conventional method was associated with a higher percentage of survivors. This technique was found to be satisfactory unless severe dilatation or complete destruction of the aortic annulus made composite grafting necessary. The latter technique was associated with fewer re-explorations for postoperative hemorrhage. Both procedures were equally effective, resulting in an operative mortality of 10% in uncomplicated situations. Surgery appeared to offer the only chance of survival for the high-risk group, and half of these patients were salvaged.  相似文献   

4.
Two patients are presented in whom dissection of the ascending aorta resulted from cannulation for arterial return and from the infusion of cardioplegic solution. The dissections were recognized promptly. Following dissection in the first patient, the femoral artery was used to reestablish systemic perfusion. The aortic valve and dissected ascending aorta were replaced, and three vessels were grafted. In the second patient, the dissected anterior wall of the ascending aorta was excised and replaced with a low-porosity Dacron patch into which the proximal aortocoronary anastomoses were inserted. Predisposing factors are discussed, along with preventive measures and methods of repair.  相似文献   

5.
Two Jehovah's Witnesses with large ascending thoracic aortic aneurysms and aortic insufficiency secondary to annuloaortic ectasia underwent successful combined replacement of the aortic valve and the ascending aorta. One patient received a composite graft containing an aortic valve prosthesis, which necessitated supravalvular coronary ostia reimplantation; the other patient underwent separate aortic valve and left supracoronary ascending aneurysm replacement, with reimplantation of the right coronary ostium into the graft. No blood or blood derivatives were administered. Both patients had uneventful recoveries and continue to do well. To our knowledge, they represent the first reported cases of successful combined replacement of the aortic valve and ascending aorta in Jehovah's Witnesses.  相似文献   

6.
A diffuse aneurysm of the ascending aorta was observed five months after prosthetic valve implantation in to mitral and aortic orifices because of the acquired valvular heart disease. The main factor predisposing to the formation of a false aneurysm was an infection of the endocardium and ascending aortal wall which were observed previously during cardiac surgery. The diagnosis, based on the clinical symptoms and non-invasive investigations, was later confirmed with aortography and intra-operatively.  相似文献   

7.

Background

Bicuspid aortic valve (BAV) is one of the most common congenital heart defects with a population prevalence of 0.5% to 1.3%. Identifying patients with BAV is clinically relevant because BAV is associated with aortic stenosis, endocarditis and ascending aorta pathology.

Methods and Results

Patients with severe aortic stenosis necessitating aortic valve replacement surgery were included in this study. All dissected aortic valves were stored in the biobank of the University Medical Centre Utrecht. Additionally to the morphological assessment of the aortic valve by the surgeon and pathologist, echocardiographic and magnetic resonance imaging (MRI) images were evaluated. A total of 80 patients were included of whom 32 (40%) were diagnosed with BAV by the surgeon (gold standard). Patients with BAV were significantly younger (55 vs 71 years) and were more frequently male. Notably, a significant difference was found between the surgeon and pathologist in determining valve morphology. MRI was performed in 33% of patients. MRI could assess valve morphology in 96% vs 73% with echocardiography. The sensitivity of MRI for BAV in a population of patients with severe aortic stenosis was higher than echocardiography (75% vs 55%), whereas specificity was better with the latter (91% vs 79%). Typically, the ascending aorta was larger in patients with BAV.

Conclusion

Among unselected patients with severe aortic valve stenosis, a high percentage of patients with BAV were found. Imaging and assessment of the aortic valve morphology when stenotic is challenging.  相似文献   

8.
In this case report, we present the use of intracardiac echocardiography (ICE) for guiding the cardiac catheterization and subsequent hemodynamic investigation in an unusual patient case with multiple congenital abnormalities (bicuspid aortic valve, left cervical aortic arch, two aortic coarctations) and two aortic valve replacement operations in the past. The ICE catheter (AcuNav) permitted us to accurately and safely puncture the interatrial septum and place the Swan-Ganz catheter in the left ventricle; additionally, visualization of the aortic coarctation in the ascending aorta was also achieved.  相似文献   

9.
Steady flow studies were conducted in a transparent canine aortic cast. The cast segment stretched from the aortic valve to beyond the renal arteries and included all major branches. Flow was visualized by analysis of dye streaklines. Flow rates for basal and exercising cardiovascular states were simulated. The Reynolds numbers in the ascending aorta for basal and exercising conditions were 900 and 1587 respectively. Aortic core flow was laminar in basal simulations. Disturbed flow commenced in the upper descending aorta with exercising flow rates. Separation zones existed along the inner curvature of the aortic arch and the proximal walls of the brachiocephalic, left subclavian, and coeliac arteries. Such zones may exist over a portion of the cardiac cycle. If either renal artery was occluded, then a vortex formed. This vortex is associated with high shear regions which correlate well with sites where sudanophilic lesions have been reported in cholesterol-fed nephrectomized rabbits.  相似文献   

10.
In this piece of work, we attempt to highlight our approach and early experience with minimally invasive aortic valve replacement with aortic Freedom Solo stentless bioprosthesis performed through an upper manubrium-limited ministernotomy in the second intercostal space. The novel suturing technique is required for stentless aortic bioprosthesis implantation, and this, in its turn, will predetermine and influence the surgeon's choice for operative access. In our department, the feasibility of the approach was first assessed; aortic valve was replaced by stentless bioprosthesis in a total of 23 patients (mean age 57 ± 12 years). In all cases, a cardiopulmonary bypass was established by a central ascending aorta cannulation and peripheral percutaneous venous cannula insertion. This approach was found to be technically reproducible and safe. The surgical technique used is described in this article.  相似文献   

11.
Dilatation of the ascending aorta (AAD) is a prevalent aortopathy that occurs frequently associated with bicuspid aortic valve (BAV), the most common human congenital cardiac malformation. The molecular mechanisms leading to AAD associated with BAV are still poorly understood. The search for differentially expressed genes in diseased tissue by quantitative real-time PCR (qPCR) is an invaluable tool to fill this gap. However, studies dedicated to identify reference genes necessary for normalization of mRNA expression in aortic tissue are scarce. In this report, we evaluate the qPCR expression of six candidate reference genes in tissue from the ascending aorta of 52 patients with a variety of clinical and demographic characteristics, normal and dilated aortas, and different morphologies of the aortic valve (normal aorta and normal valve n = 30; dilated aorta and normal valve n = 10; normal aorta and BAV n = 4; dilated aorta and BAV n = 8). The expression stability of the candidate reference genes was determined with three statistical algorithms, GeNorm, NormFinder and Bestkeeper. The expression analyses showed that the most stable genes for the three algorithms employed were CDKN1β, POLR2A and CASC3, independently of the structure of the aorta and the valve morphology. In conclusion, we propose the use of these three genes as reference genes for mRNA expression analysis in human ascending aorta. However, we suggest searching for specific reference genes when conducting qPCR experiments with new cohort of samples.  相似文献   

12.
Pulsatile flow development past a caged ball valve in a model human aorta was studied using laser Doppler anemometry. Velocity profiles measured in the ascending aorta and in the mid-arch region were strongly influenced by the geometry of the valve at the root of the aorta. Velocity profiles distal to the valve were asymmetric with jet-like flow in the peripheral region having larger velocity magnitudes towards the left lateral wall. In early diastole, a streamwise vortex motion was observed throughout the model aorta with fluid moving towards the downstream direction along the left lateral wall and reversed flow along the right lateral wall. With the caged ball valve at the root of the aorta, no reversed flow was observed along the inner wall of curvature in the mid-arch region.  相似文献   

13.
14.
Bicuspid aortic valves (BAVs) generate flow abnormalities that may promote aortopathy. While positive helix fraction (PHF) index, flow angle (θ), flow displacement (d) and wall shear stress (WSS) exhibit abnormalities in dilated BAV aortas, it is unclear whether those anomalies stem from the abnormal valve anatomy or the dilated aorta. Therefore, the objective of this study was to quantify the early impact of different BAV morphotypes on aorta hemodynamics prior to dilation. Fluid-structure interaction models were designed to quantify standard peak-systolic flow metrics and temporal WSS characteristics in a realistic non-dilated aorta connected to functional tricuspid aortic valve (TAV) and type-I BAVs. While BAVs generated increased helicity (PHF>0.68) in the middle ascending aorta (AA), larger systolic flow skewness (θ>11.2°) and displacement (d>6.8 mm) relative to the TAV (PHF=0.51; θ<5.5°; d<3.3 mm), no distinct pattern was observed between morphotypes. In contrast, WSS magnitude and directionality abnormalities were BAV morphotype- and site-dependent. Type-I BAVs subjected the AA convexity to peak-systolic WSS overloads (up to 1014% difference vs. TAV). While all BAVs increased WSS unidirectionality on the proximal AA relative to the TAV, the most significant abnormality was achieved by the BAV with left-right-coronary cusp fusion on the wall convexity (up to 0.26 decrease in oscillatory shear index vs. TAV). The results indicate the existence of strong hemodynamic abnormalities in non-dilated type-I BAV AAs, their colocalization with sites vulnerable to dilation and the superior specificity of WSS metrics over global hemodynamic metrics to the valve anatomy.  相似文献   

15.
T Toda 《Jikken dobutsu》1988,37(2):179-185
A total of 13 forty-day-old male Japanese quails had free access to a atherogenic diet containing 15% corn oil and 2% cholesterol or commercial basal diet for 3 months. Birds fed basal diet showed no significant intimal lesions. These birds had two types of cells, i.e. smooth muscle cell and fibroblast-like cell, in the tunica media of the ascending aorta. While fat-fed birds showed marked lipid-rich intimal lesions in the ascending aorta but not in the abdominal aorta. Some macrophage-derived foam cells, which were stained for lysozyme and OKM1, were demonstrated in the superficial portion of the thickened intima. The majority of the cells in the lipid-rich thickened intima showed ultrastructural character of fibroblast-like cells with or without lipid droplets. Alpha-1-antichymotrypsin was positive for fibroblast-like cells in the thickened intima but not for those in the tunica media of the ascending aorta. These results suggest that metaplasia of the medial fibroblast-like cells is responsible for the development of atherosclerosis in the quail.  相似文献   

16.
A transient fluid–structure interaction (FSI) model of a congenitally bicuspid aortic valve has been developed which allows simultaneous calculation of fluid flow and structural deformation. The valve is modelled during the systolic phase (the stage when blood pressure is elevated within the heart to pump blood to the body). The geometry was simplified to represent the bicuspid aortic valve in two dimensions. A congenital bicuspid valve is compared within the aortic root only and within the aortic arch. Symmetric and asymmetric cusps were simulated, along with differences in mechanical properties. A moving arbitrary Lagrange–Euler mesh was used to allow FSI. The FSI model requires blood flow to induce valve opening and induced strains in the region of 10%. It was determined that bicuspid aortic valve simulations required the inclusion of the ascending aorta and aortic arch. The flow patterns developed were sensitive to cusp asymmetry and differences in mechanical properties. Stiffening of the valve amplified peak velocities, and recirculation which developed in the ascending aorta. Model predictions demonstrate the need to take into account the category, including any existing cusp asymmetry, of a congenital bicuspid aortic valve when simulating its fluid flow and mechanics.  相似文献   

17.
Bicuspid aortic valve (BAV) is associated with aortic dilatation and aneurysm. Several studies evidenced an eccentric systolic flow in ascending aorta associated with increased wall shear stresses (WSS) and the occurrence of an helical systolic flow. This study seeks to elucidate the connections between jet asymmetry and helical flow in patients with normally functioning BAV and dilated ascending aorta. We performed a computational parametric study by varying, for a patient-specific geometry, the valve area and the flow rate entering the aorta and drawing also a tricuspid valve (TAV). We considered also phase-contrast magnetic resonance imaging of four BAV and TAV patients. Measurement of normalized flow asymmetry index, systolic WSS and of a new index (positive helix fraction, PHF) quantifying the presence of a single a single helical flow were performed. In our computation, BAV cases featured higher values of all indices with respect to TAV in both numerical and imaged-based results. Moreover, all indices increased with decreasing valve area and/or with increasing flow rate. This allowed to separate the BAV and TAV cases with respect to the jet asymmetry, WSS localization and helical flow. Interestingly, these results were obtained without modeling the leaflets.  相似文献   

18.

Aims

Thoracic aortic aneurysm (TAA) is potentially life-threatening and requires close follow-up to prevent aortic dissection. Aortic stiffness and size are considered to be coupled. Regional aortic stiffness in patients with TAA is unknown. We aimed to evaluate coupling between regional pulse wave velocity (PWV), a marker of vascular stiffness, and aortic diameter in TAA patients.

Methods

In 40 TAA patients (59 ± 13 years, 28 male), regional aortic diameters and regional PWV were assessed by 1.5 T MRI. The incidence of increased diameter and PWV were determined for five aortic segments (S1, ascending aorta; S2, aortic arch; S3, thoracic descending aorta; S4, suprarenal and S5, infrarenal abdominal aorta). In addition, coupling between regional PWV testing and aortic dilatation was evaluated and specificity and sensitivity were assessed.

Results

Aortic diameter was 44 ± 5 mm for the aortic root and 39 ± 5 mm for the ascending aorta. PWV was increased in 36 (19 %) aortic segments. Aortic diameter was increased in 28 (14 %) segments. Specificity of regional PWV testing for the prediction of increased regional diameter was ≥ 84 % in the descending thoracic to abdominal aorta and ≥ 68 % in the ascending aorta and aortic arch.

Conclusion

Normal regional PWV is related to absence of increased diameter, with high specificity in the descending thoracic to abdominal aorta and moderate results in the ascending aorta and aortic arch.  相似文献   

19.
In Part II of this two paper sequence, pulsatile flow development past a tilting disc valve in a model human aorta has been studied using quantitative laser Doppler techniques. The valve was mounted in three different orientations with respect to the aortic root in this study. Under pulsatile flow, the region of flow reversal induced near the wall of the minor flow orifice extends to more than one tissue annulus diameter downstream from the valve into the ascending aorta. In a plane perpendicular to the tilt axis, a bi-helical secondary flow is induced distal to the valve. This secondary flow is further compounded by the multiple curvatures in the aorta. Hence the valve orientation affects the velocity profiles as far downstream as the mid-arch region as well as in the brachio-cephalic arterial branch. In the mid-arch region, a flow reversal along the entire cross-section is observed in early diastole for all the three orientations of the disc valve.  相似文献   

20.

Background

The clinical course of bicuspid aortic valves (BAVs) is variable. Data on predictors of aortopathy and valvular dysfunction mainly focus on valve morphology.

Aim

To determine whether the presence and extent of the raphe (fusion site of valve leaflets) is associated with the degree of aortopathy and valvular dysfunction in patients with isolated BAV and associated aortic coarctation (CoA).

Methods

Valve morphology and aortic dimensions of 255 BAV patients were evaluated retrospectively by echocardiography.

Results

BAVs with a complete raphe had a significantly higher prevalence of valve dysfunction (especially aortic regurgitation) than BAVs with incomplete raphes (82.9 vs. 66.7 %, p = 0.01). Type 1A BAVs (fusion of right and left coronary leaflets) and complete raphe had larger aortic sinus diameters compared with the rest of the population (37.74 vs. 36.01, p = 0.031). Patients with CoA and type 1A BAV had significantly less valve regurgitation (13.6 vs. 55.8 %, p < 0.001) and smaller diameters of the ascending aorta (33.7 vs. 37.8 mm, p < 0.001) and aortic arch (25.8 vs. 30.2 mm, p < 0.001) than patients with isolated BAV.

Conclusions

Type 1A BAV with complete raphe is associated with more aortic regurgitation and root dilatation. The majority of CoA patients have incomplete raphes, associated with smaller aortic root diameters and less valve regurgitation.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号