共查询到20条相似文献,搜索用时 7 毫秒
1.
A method for the isolation and concentration of the monoglutamate forms of folate cofactors from tissues and for their subsequent separation and quantitation using HPLC coupled with uv detection at 284 nm is described. A chromatographic procedure utilizing Dowex 50 has been developed for the separation of the folate monoglutamates from a large portion of the nonfolate-related material following digestion of the polyglutamated froms with a highly purified preparation of rat liver conjugase. This chromatographic procedure combined with concentration of the Dowex eluate by lyophilization eliminates uv-absorbing material, which interferes with the detection and quantitation of the folate cofactors and makes possible uv measurement of the individual folates. Reverse-phase paired-ion chromatography on μBondapak C18 coupled with uv detection allows direct quantitation of the folates in the nanogram range. 相似文献
2.
The addition of a 20-base GC-clamp to a DNA fragment enabled mutations to be detected by denaturing high-performance liquid chromatography (DHPLC) in the higher melting domain of the two-domain fragment DYS271. The mutations were undetectable in the absence of the GC-clamp. The heteroduplex yield was greatly decreased by the presence of mutations in the high melting domain, presumably because this region anneals first during cooling, leading to selection of the more stable homoduplexes. Suppression of sequence-dependent melting behavior using betaine increased the heteroduplex yield almost four-fold. Mutations in the high melting domain were detected at 60 degrees C, whereas mutations in the low melting domain were detected at 56 degrees C. Computer modeling of the melting behavior agreed well with the experimental results, facilitating computer design of DHPLC amplicons. 相似文献
3.
Quantitative analysis of tissue folate using ultra high-performance liquid chromatography tandem mass spectrometry 总被引:1,自引:0,他引:1
The tissue distribution of folate in its numerous coenzyme forms may influence the development of disease at different sites. For instance, the susceptibility of human colonic mucosa to localized folate deficiency may predispose to the development of colorectal cancer. We report a sensitive and robust ultra high-performance liquid chromatography (UHPLC) tandem mass spectrometry method for quantifying tissue H4folate, 5-CH3-H4folate, 5-CHO-H4folate, folic acid, and 5,10-CH+-H4folate concentration. Human colonic mucosa (20–100 mg) was extracted using lipase and conjugase enzyme digestion. Rapid separation of analytes was achieved on a UHPLC 1.9-μm C18 column over 7 min. Accurate quantitation was performed using stable isotopically labeled (13C5) internal standards. The instrument response was linear over physiological concentrations of tissue folate (R2 > 0.99). Limits of detection and quantitation were less than 20 and 30 fmol on column, respectively, and within- and between-run imprecision values were 6–16%. In colonic mucosal samples from 73 individuals, the average molar distribution of folate coenzymes was 58% 5-CH3-H4folate, 20% H4folate, 18% formyl-H4folate (sum of 5-CHO-H4folate and 5,10-CH+-H4folate), and 4% folic acid. This assay would be useful in characterizing folate distribution in human and animal tissues as well as the role of deregulated folate homeostasis on disease pathogenesis. 相似文献
4.
F Y Choy 《Analytical biochemistry》1989,179(2):312-318
Glucocerebrosidase from human skin fibroblasts was purified more than 2300-fold to apparent homogeneity with an overall yield of 39% using taurocholate extraction, ammonium sulfate fractionation, and high-performance hydrophobic interaction and gel permeation column chromatography. This relatively high yield is attributed to two modifications from previously published procedures: (i) the elimination of a butanol delipidation step that resulted in substantial loss of enzyme activity; and (ii) the use of 2% (w/v) sodium taurocholate instead of 1-2% sodium cholate that resulted in more than 90% solubilization of total membrane-bound enzyme activity. Confluent monolayers of human cultured skin fibroblasts (approximately 3.6 x 10(8) cells) were harvested from 10 roller bottles. Glucocerebrosidase in the cell pellet was solubilized with 2% (w/v) sodium taurocholate, fractionated in 14% ammonium sulfate, and applied to a high-performance hydrophobic interaction phenyl-5PW column. After an ammonium sulfate descending linear gradient step, glucocerebrosidase was eluted from the column at 4% cholate concentration using a 0-5% linear cholate gradient. There was a 36-fold purification and 80% recovery. In the subsequent step, concentrated glucocerebrosidase fractions from the phenyl column were injected into two Bio-Sil TSK-250 gel permeation columns joined in series. Glucocerebrosidase peak activity was eluted at 263 ml corresponding to Mr 76,000. There was an 18-fold purification and 78% recovery. The enzyme preparation was then recycled through the phenyl-5PW column in order to remove a remaining contaminant.(ABSTRACT TRUNCATED AT 250 WORDS) 相似文献
5.
A reverse-phase high-performance liquid chromatographic method has been developed to determine the sites of reaction and the product distribution of modified salmon sperm DNA. The DNA was reacted with methyl methanesulfonate in neutral solution, and then degraded into deoxyribonucleosides by snake venom phosphodiesterase and alkaline phosphatase. Four products were identified and quantitated: 7-methyldeoxyguanosine (37.1%), 7-methylguanine (7.3%), 3-methyldeoxycytidine (28.8%), and 1-methyldeoxyadenosine (26.8%). This method provides a rapid procedure for analysis of chemically or biochemically modified nucleic acids. 相似文献
6.
《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1995,672(2):300-304
A sensitive high-performance liquid chromatographic (HPLC) method for the determination of metronidazole in vaginal tissue is reported. The method uses a Zorbax SB phenyl column with a 0.01 M aqueous monobasic potassium phosphate buffer (pH 4.0)-absolute methanol (85:15, v/v) as mobile phase at a flow-rate of 1.0 ml/min and detection at 313 nm. Tinidazole was used as the internal standard. The method employed homogenization of tissue followed by solid-phase extraction. The quantitation was achieved within 30 min with sensitivity in the ng/g range. Metronidazole was linear in the 100–2000 ng/g range. The accuracy and precision were in the 1–4% range for the drug and the limit of detection was approximately 100 ng/g based on a signal-to-noise ratio of 3 and a 100-μl injection. 相似文献
7.
K. Rna K. Ary 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2001,755(1-2)
A rapid, simple reversed-phase high-performance liquid chromatographic method with ultraviolet absorbance detection has been developed for the determination of calcium dobesilate in human plasma. Sample processing is based on an ion-pairing extraction with tetra-n-butylammonium hydroxide as cationic pairing ion and dichloromethane. Separation of the investigated calcium dobesilate and 2,4-dihydroxybenzoic acid as internal standard was achieved on a Discovery RP-Amide C16 analytical column with 50 mM, pH 2.5, potassium dihydrogenphosphate buffer–acetonitrile (75:25, v/v) mobile phase. The wavelength was set at 305 nm. The limit of quantitation is 100 ng/ml and the calibration curve is linear up to 50 μg/ml. Within-day and between-day precision expressed as the relative standard deviation is about 10% and the accuracy of the determination did not deviate from 100% by more than ±10%. The developed method was found to be suitable for application in human bioequivalence studies. 相似文献
8.
Liebich HM Müller-Hagedorn S Bacher M Scheel-Walter HG Lu X Frickenschmidt A Kammerer B Kim KR Gérard H 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2005,814(2):275-283
Modified nucleosides have been characterized as tumor markers for a number of malignant diseases. In order to use these markers in children, the age-dependence of the nucleoside levels in healthy children has to be established and taken into account in diagnostic decisions. In this study, the levels of 12 normal and modified nucleosides in urine of 166 healthy children and adolescents with an age between 1 day and 19 years are determined by reversed-phase HPLC, and age-dependent reference ranges are defined. The urinary nucleoside concentrations are related to the creatinine concentrations, which allows the use of randomly collected urine samples. All nucleoside levels in urine of children decrease with age, most pronounced during the first 4 years of life, and the age-dependence of the reference values of the individual nucleosides can be approximated by a mathematical function y = b(0) + b(1) (1/x) with the regression coefficients b(0) and b(1,) the nucleoside levels y and the age x between 1 year and 19 years. In the very young children, the shifts in the nucleoside concentrations are more differentiated. Starting with low levels on the first day of life, the concentrations of all studied nucleosides rise up to an age of 1-2 months, when they reach their absolute maximum for all age periods, and then decrease. 相似文献
9.
Sun T Xu Z Godber JS 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2006,830(1):158-160
Four sample preparation methods, (1) solvent (SOL), (2) saponification and solvent (SP), (3) ultrasound assisted solvent (UA), and (4) saponification and ultrasound assisted solvent (SP-UA), were used for quantifying lutein in chicken liver samples by HPLC. The lutein concentrations obtained by using SOL, UA, SP, and SP-UA were significantly different with values from 10.4 microg/g (UA) to undetected (SOL). Efficiency of the four different methods for extracting lutein from high to low were the UA, SP, SP-UA, and SOL method. The measured value of lutein in the liver sample using the UA method was approximately two and three times higher than that obtained from the SP and SP-UA method, respectively. The methods with saponification significantly affected the stabilities of lutein in liver samples. The lutein concentration measured with the solvent only method was either much lower than any of the other extraction methods or undetectable. This indicated that little lutein in those samples was in a form that could be extracted directly by solvent. Compared with the saponification method, the ultrasound assisted solvent method could effectively extract lutein from sample matrix and thus avoid chemical degradation reactions, which would be especially important for complex biological tissue such as liver. 相似文献
10.
Acetylglutamate in HClO4 tissue extracts is first separated from glutamate by ion exchange. It is then deacylated with aminoacylase, and the resulting glutamate, after adsorption to and elution from an AG 50 column, is quantitated by a fast-HPLC method using o-phthaldialdehyde precolumn derivatization, separation in a C18 reverse-phase column, and fluorescence detection. A linear response is obtained up to 2 nmol, the detection limit is 5 pmol, and the method is suitable for assay in 1 mg liver tissue and thus for needle biopsies. When samples were analyzed by this procedure and by earlier procedures based upon detection of glutamate with glutamate dehydrogenase or upon activation of carbamoyl phosphate synthetase the results were similar. The method, which is highly specific, compares favorably in sensitivity, precision, and accuracy with all other published procedures. Using this assay, no acetylglutamate has been found in chicken liver and rat kidney. 相似文献
11.
12.
《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1995,665(1):163-170
We have developed an assay for the simultaneous determination of methotrexate (MTX) and its main metabolites, 7-hydroxymethotrexate (7-OHMTX) and 2,4-diamino-N10-methylpteroic acid (DAMPA) in plasma, urine and saliva meeting the requirement of rapidity for routine use in high-dose MTX therapy and the requirement of sensitivity for its potential use in therapeutic drug monitoring in low-dose MTX therapy. Sample preparation is based on solid-phase extraction using C8 Isolute cartridges. Chromatographic separation was achieved with a reversed-phase column (C18), and quantitation by subsequent exposure to UV light of 254 nm, which converted MTX and its two metabolites by photolytic oxidation to fluorescent products. The recoveries of MTX, 7-OHMTX and DAMPA from plasma at 100 nmol/1 were 85.8, 91.1 and 102.3%, respectively. The limits of detection for MTX, 7-OHMTX and DAMPA in plasma and saliva were 0.1 nmol/1. In urine the limit of detection was 10 nmol/1 for all compounds. The limits of quantitation in plasma and saliva were 0.5 nmol/1 for all compounds. 相似文献
13.
Solid-phase extraction and high-performance liquid chromatography analysis of lipoxygenase pathway products 总被引:2,自引:0,他引:2
Liquid chromatography methods for quantitation of leukotrienes and HETEs (hydroxyeicosatetraenoic acids) in biological samples are described. Extraction is accomplished by acetonitrile precipitation of proteins followed by selective acetonitrile elution from a solid-phase C18 extraction cartridge. Isocratic elution of extracts from short reverse-phase columns with 3 microns C18-bonded silica results in elution of all components of interest in less than 10 min. The addition of the mobile-phase additives, trifluoroacetic acid and triethylamine, enable the peptido-leukotrienes to be eluted with excellent peak shape and unique elution times. As little as 1 pmol of each metabolite can be detected by uv spectrophotometry with a wavelength change from 280 to 235 nm midway through the chromatographic run. This method is demonstrated by the extraction and analysis of leukotriene and HETE standards from human serum. 相似文献
14.
alpha-Latrotoxin, a main toxic component of the Latrodectus mactans tredecimguttatus venom is a large polypeptide with molecular weight of 130 KDa. A rapid method is suggested for isolating this protein using high-effective liquid chromatography on chromatograph FPLC ("Pharmacia", Sweden). The isolated protein does not differ from the previously described alpha-latrotoxin in the main physicochemical parameters as well as in physiological properties. 相似文献
15.
Ion-exchange high-performance liquid chromatography of oligodeoxyribonucleotides using formamide 总被引:4,自引:0,他引:4
C R Newton A R Greene G R Heathcliffe T C Atkinson D Holland A F Markham M D Edge 《Analytical biochemistry》1983,129(1):22-30
The superiority of buffer systems containing formamide for the ion-exchange high-performance liquid chromatographic separation of oligodeoxyribonucleotide mixtures generated in solid-phase syntheses is illustrated. The resolutions achieved are compared to those achieved with the same mixtures in other eluting solvents. The use of formamide systems is recommended for oligodeoxyribonucleotide purification in general and is particularly valuable where the oligonucleotide of interest is highly self-complementary and/or rich in deoxyguanosine residues. 相似文献
16.
17.
S.Shi-hua Chen Anne Y. Kou 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1982,227(1):25-31
We describe a rapid and efficient high-performance liquid chromatography procedure for the separation of phospholipids. The separation is accomplished on a microparticulate silica gel column using isocratic elution and UV detection at 203 nm. The solvent mixture is acetonitrile—methanol—85% phosphoric acid(130:5:1.5, v/v). Complete separation is achieved within 30 min of phosphatidylinositol, phosphatidylserine, phosphatidylethanolamine, phosphatidyldimethylethanolamine, lysophosphatidylethanolamine, phosphatidylcholine, lysophosphatidylcholine and sphingomyelin. The method is suitable for the analysis of phospholipids in tissue extracts. 相似文献
18.
Cui Y Gurley B Ang CY Leakey J 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2002,768(1):129-135
The role of the Mg2+ cation on antihypertensive molecule binding on human serum albumin (HSA) was studied by affinity chromatography. The thermodynamic data corresponding to this binding were determined for a wide range of Mg2+ concentrations (c). For the nifedipine molecule, an increase in the Mg2+ concentration produced a decrease in binding due to a decrease in the electrostatic interactions. For verapamil and diltiazem, which have the highest solvent accessible surface area, the solute binding on HSA was divided into two Mg2+ concentration regions. For a low c value below c(c) (approximately 1.6 mmol/l), the binding dependence with c was similar to that of nifedipine. For c above c(c) the hydrophobic effect created in the bulk solvent associated with a decrease in the van der Waals interactions between the solute molecule and the HSA implied a decrease in its binding. These results showed that for patients with hypertension, an Mg2+ supplementation during treatment with these antihypertensive molecules can increase the active pharmacological molecule concentration. 相似文献
19.
《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2001,751(1):161-167
Previously [Anal. Biochem., 232 (1995) 163–171], we reported a high-performance liquid chromatography (HPLC) assay method for human plasma lipoproteins using a diethylaminoethyl (DEAE)-glucomannan column, which is not commercially available. In this study, HPLC assay methods for lipoproteins in plasma samples of human and experimental animals, and modified low-density lipoproteins (LDLs) of rabbits have been developed using a commercially available anion-exchange ProtEx-DEAE column. For the assays of plasma lipoproteins, the method includes complete separation of high-density lipoproteins, LDLs and very low-density lipoproteins within 20 min using stepwise elution, and determination by post-column reaction with an enzymatic cholesterol reagent as the total cholesterol (TC) level. Similarly, mild oxidative and artificially oxidised LDLs were separated into their subfractions using stepwise elution, and determined based on the TC level. The methods using the DEAE-glucomannan and ProtEx-DEAE columns were cross-validated. There was an excellent correlation between the two methods. The obtained results reveal that the anion-exchange HPLC method using the ProtEx-DEAE column could be useful for the assays of plasma lipoproteins and modified LDLs. 相似文献
20.
Mitsuhiro Ishida Kayoko Kobayashi Norio Awata Fumio Sakamoto 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1999,727(1-2)
A simple and reproducible method for the analysis of ampicillin in human serum was developed. Serum samples were extracted using solid-phase extraction disk cartridges containing a sorbent of styrene divinyl/benzene. Extracts were separated by reversed-phase C18 high-performance liquid chromatography with UV detection at 220 nm. The mobile phase consisted of acetonitrile–10 mM NaH2PO4 (6.5:93.5, v/v). Using this extraction procedure, recovery from serum was 98.4±5.6%. The quantitation limit was 0.19 μg/ml using 0.5 ml of serum. The calibration curves from 0.19 to 9.41 μg/ml were linear with correlation coefficients of 0.999. This method is suitable for therapeutic drug monitoring of ampicillin (ABPC) after oral administration of lenampicillin hydrochloride. 相似文献