首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 602 毫秒
1.
The USP Apparatus 3 is a compendial dissolution Apparatus that has been mainly used to assess the performance of modified-release drug products. However, this Apparatus can be applied to dissolution testing of immediate-release tablets as well, with several advantages such as lower consumption of dissolution media, reduced setup time in quality control routine, and minimized hydrodynamic issues. In this work, three immediate-release (IR) tablets containing antihypertensive drugs of different Biopharmaceutic Classification System (BCS) classes were evaluated in order to assess the possible interchangeability between the official dissolution method using typical USP Apparatus 1 or 2 and the proposed methods using USP Apparatus 3. Depending on the selection of the appropriate operational conditions, such as dip rate and sieve mesh size, it was observed that USP Apparatus 3 could provide similar dissolution profiles compared to USP Apparatus 1 or 2 to the drug products tested. In addition, USP Apparatus 3 avoided conning issues related to USP Apparatus 2. The successful application of USP Apparatus 3 in dissolution tests for IR drug products depends on the definition of specific test conditions for each product, considering all the equipment variables, as well as drug and formulation characteristics.  相似文献   

2.
The goal of this article is to discuss the classification of video recordings and images when applied to dissolution testing in USP apparatus 1 and 2. Three use cases are presented. The first case presents the use and classification of video as RBE (review by exception) data under GAMP 5. The second case presents the use of video in formulation development in a research and development environment. The third case presents a feasibility study using readily available computer vision software to recognize and measure objects in the dissolution vessel, setting the groundwork for the use of image analysis as a quantitative tool. The classification of video as “electronic data”, requiring 21 CFR part 11 compliance, versus its classification as a RBE data under GAMP 5, likely depends upon its use case. Another goal of this article is to establish a position on the use of video monitoring technology as a tool for dissolution testing that is fit for purpose and compliant with regulations regarding video data management and information.Key words: computer vision, dissolution, GAMP, USP, video monitoring  相似文献   

3.
The goal of this article is to discuss considerations regarding implementation of the parametric tolerance interval two one-sided test (PTI-TOST) for delivered dose uniformity (DDU) of orally inhaled products (OIPs). That test was proposed by FDA in 2005 as an alternative to the counting test described in the 1998 draft FDA guidance for metered dose inhalers and dry powder inhalers. The 2005 PTI-TOST, however, still has not found much use in practice despite the general desirability of parametric approaches in modern pharmaceutical quality control. A key reason for its slow uptake is that it rejects, with high probability, batches whose quality is considered acceptable by all other published regulatory and pharmacopeial standards as well as by the DDU specifications for many approved OIPs. Manufacturers therefore continue using nonparametric counting tests for control of DDU. A simulated case study presented here compares the consequences of the PTI-TOST compared to the counting test. The article discusses three possibilities that would help increase the uptake of the PTI-TOST approach, namely: product-specific quality standards, a different default standard suitable for the majority of OIPs, and integration of the PTI-TOST with a continuous verification control strategy rather than using it as an isolated-batch (transactional) end-product testing. In any of these efforts, if a parametric test is used, it is critical not to set the target quality close to, or at the boundary of the process/product capabilities, because PTI tests are designed to reject with high probability the identified target quality.  相似文献   

4.
In the sublingual (SL) cavity, compared with the gastrointestinal tract, tablets are subjected to minimal physiological agitation, and a limited volume of saliva is available to facilitate disintegration and dissolution. None of the official compendial dissolution apparatuses and methods simulate these SL conditions. In this study, a custom-made dissolution apparatus was constructed, and a novel in vitro method that simulates SL conditions was evaluated. Several epinephrine 40 mg SL tablet formulations under development and two commercial SL tablets, isosorbide dinitrate 5 mg and nitroglycerin 0.6 mg, were studied. The dissolution medium was 2 mL of distilled water at 25°C. Dissolution was measured at 60 and 120 s. The novel in vitro method was validated for accuracy, reproducibility, and discrimination capability, and was compared with the official US Pharmacopeia (USP) dissolution method using apparatus 2 (Paddle). The data obtained following the novel in vitro method were accurate and reproducible. This method was capable of detecting minor changes in SL formulations that could not be detected using other in vitro tests. Results from the official USP dissolution method and our novel in vitro method were significantly different (p < 0.05). Results reflecting the dissolution of rapidly disintegrating tablets using simulated SL conditions were obtained using the novel in vitro dissolution method.  相似文献   

5.
Recent interest in the development of drug particle-laden strip-films suggests the need for establishing standard regulatory tests for their dissolution. In this work, we consider the dissolution testing of griseofulvin (GF) particles, a poorly water-soluble compound, incorporated into a strip-film dosage form. The basket apparatus (USP I) and the flow-through cell dissolution apparatus (USP IV) were employed using 0.54% sodium dodecyl sulfate as the dissolution medium as per USP standard. Different rotational speeds and dissolution volumes were tested for the basket method while different cell patterns/strip-film position and dissolution media flow rate were tested using the flow-through cell dissolution method. The USP I was not able to discriminate dissolution of GF particles with respect to particle size. On the other hand, in the USP IV, GF nanoparticles incorporated in strip-films exhibited enhancement in dissolution rates and dissolution extent compared with GF microparticles incorporated in strip-films. Within the range of patterns and flow rates used, the optimal discrimination behavior was obtained when the strip-film was layered between glass beads and a flow rate of 16 ml/min was used. These results demonstrate the superior discriminatory power of the USP IV and suggest that it could be employed as a testing device in the development of strip-films containing drug nanoparticles.Key Words: BCS class II, dissolution, drug nanoparticles, flow-through cell, pharmaceutical strip-films  相似文献   

6.
The purpose of this article is to catalogue in a systematic way the available information about factors that may influence the outcome and variability of cascade impactor (CI) measurements of pharmaceutical aerosols for inhalation, such as those obtained from metered dose inhalers (MDIs), dry powder inhalers (DPIs) or products for nebulization; and to suggest ways to minimize the influence of such factors. To accomplish this task, the authors constructed a cause-and-effect Ishikawa diagram for a CI measurement and considered the influence of each root cause based on industry experience and thorough literature review. The results illustrate the intricate network of underlying causes of CI variability, with the potential for several multi-way statistical interactions. It was also found that significantly more quantitative information exists about impactor-related causes than about operator-derived influences, the contribution of drug assay methodology and product-related causes, suggesting a need for further research in those areas. The understanding and awareness of all these factors should aid in the development of optimized CI methods and appropriate quality control measures for aerodynamic particle size distribution (APSD) of pharmaceutical aerosols, in line with the current regulatory initiatives involving quality-by-design (QbD). Editorial Comment: The International Pharmaceutical Aerosol Consortium on Regulation and Science (IPAC-RS) is an international association of innovator and generic companies that develop, manufacture or market orally inhaled and nasal drug products for local and systemic treatment of a variety of debilitating diseases such as asthma, chronic obstructive pulmonary disease and diabetes. IPAC-RS is committed to advancing consensus-based, scientifically driven standards and regulations for these products, with the purpose of facilitating the availability of high-quality, safe, and efficacious drug products to patients.  相似文献   

7.
The aim of this study was to develop and validate a discriminating in vitro release test to evaluate rivastigmine transdermal patches. The Exelon® Patch was chosen as a model transdermal product. The studies of in vitro release were designed to determine the impact of the official apparatus chosen (USP apparatus 5 and USP apparatus 6), the rotation speed, and the dissolution medium characteristics on the rivastigmine release profile from transdermal patches. Patches with different drug release profiles were tested in order to evaluate the discriminating power of the in vitro release test developed and validated. Variables such as the apparatus type, the dissolution medium, and the rotation speed have a significant influence on the drug release characteristics from a transdermal patch. The in vitro release methodologies using the USP apparatus 5 at 50 rpm and USP apparatus 6 at 25 rpm using the medium phosphate-buffered saline pH 7.4 were considered discriminative and adequate to characterize the rivastigmine (RV) release from a commercial transdermal patch, Exelon® Patch.  相似文献   

8.
The aim of the present work was the investigation of robustness and reliability of drug release from 50 to 400 mg quetiapine extended release HPMC matrix tablets towards mechanical stresses of biorelevant intensity. The tests were performed under standard conditions (USP apparatus II) as well as under simulated gastrointestinal stress conditions. Mechanical stresses including pressure and agitation were applied by using the biorelevant dissolution stress test apparatus as it has been introduced recently. Test algorithms already established in previous studies were applied to simulate fasting gastrointestinal conditions. The dissolution experiments demonstrated striking differences in the product performance among standard and stress test conditions as well as dose strengths. In USP apparatus II, dissolution profiles were affected mainly by media pH. The dissolution experiments performed in biorelevant dissolution stress test device demonstrated that stress events of biorelevant intensity provoked accelerated drug release from the tablets.  相似文献   

9.
This work aims at increasing solubility and dissolution rate of ziprasidone free base—Biopharmaceutics Classifaction System (BCS) class II compound. The authors describe a practical approach to amorphization and highlight problems that may occur during the development of formulations containing amorphous ziprasidone, which was obtained by grinding in high-energy planetary ball mills or cryogenic mills. The release of ziprasidone free base from the developed formulations was compared to the reference drug product containing crystalline ziprasidone hydrochloride—Zeldox® hard gelatin capsules. All preparations were investigated using compendial tests (USP apparatuses II and IV) as well as novel, biorelevant dissolution tests. The novel test methods simulate additional elements of mechanical and hydrodynamic stresses, which have an impact on solid oral dosage forms, especially during gastric emptying. This step may prove to be particularly important for many formulations of BCS class II drugs that are often characterized by narrow absorption window, such as ziprasidone. The dissolution rate of the developed ziprasidone free base preparations was found to be comparable or even higher than in the case of the reference formulation containing ziprasidone hydrochloride, whose water solubility is about 400 times higher than its free base.KEY WORDS: amorphization, dissolution stress test device, enhanced dissolution, solubility improvement, ziprasidone free base formulations  相似文献   

10.
Biowaivers are recommended for immediate-release solid oral dosage forms using dissolution testing as a surrogate for in vivo bioequivalence studies. Several guidance are currently available (the World Health Organization (WHO), the US FDA, and the EMEA) where the conditions are described. In this study, definitions, criteria, and methodologies according to the WHO have been applied. The dissolution performances of immediate-release metronidazole, zidovudine, and amoxicillin products purchased in South African and Indian markets were compared to the relevant comparator pharmaceutical product (CPP)/reference product. The dissolution performances were studied using US Pharmacopeia (USP) apparatus 2 (paddle) set at 75 rpm in each of three dissolution media (pH1.2, 4.5, and 6.8). Concentrations of metronidazole, zidovudine, and amoxicillin in each dissolution media were determined by HPLC. Of the 11 metronidazole products tested, only 8 could be considered as very rapidly dissolving products as defined by the WHO, whereas 2 of those products could be considered as rapidly dissolving products but did not comply with the f2 acceptance criteria in pH 6.8. All 11 zidovudine products were very rapidly dissolving, whereas in the case of the 14 amoxicillin products tested, none of those products met any of the WHO criteria. This study indicates that not all generic products containing the same biopharmaceutics classification system (BCS) I drug and in similar strength and dosage form are necessarily in vitro equivalent. Hence, there is a need for ongoing market surveillance to determine whether marketed generic products containing BCS I drugs meet the release requirements to confirm their in vitro bioequivalence to the respective reference product.KEY WORDS: BCS, dissolution testing, generic drug, immediate-release solid oral dosage forms, WHO criteria  相似文献   

11.
As a critical member of the ubiquitin-specific proteolytic enzyme family, ubiquitin-specific peptidase 20 (USP20) regulates the stability of proteins via multiple signaling pathways. In addition, USP20 upregulation is associated with various cellular biological processes, such as cell cycle progression, proliferation, migration, and invasion. Emerging studies have revealed the pivotal role of USP20 in the tumorigenesis of various cancer types, such as breast cancer, colon cancer, lung cancer, gastric cancer and adult T cell leukemia. In our review, we highlight the different mechanisms of USP20 in various tumor types and demonstrate that USP20 regulates the stability of multiple proteins. Therefore, regulating the activity of USP20 is a novel tumor treatment. However, the clinical significance of USP20 in cancer treatment merits more evidence. Finally, different prospects exist for the continued research focus of USP20.Subject terms: Targeted therapies, Ubiquitylation  相似文献   

12.
The purpose of present study was to evaluate commercial preparations of carbamazepine tablets with respect to drug release through a defined sequence of experiments using Minitab software. The compliance of products with respect to United States Pharmacopeia (USP) dissolution test and comparison of the products with respect to drug release in different dissolution conditions is reported in the present paper. The different dissolution conditions studied include dissolution medium (1% SLS in purified water, 0.1 N HCl), volume (900 and 1,000 ml), rpm (50 rpm, 75 rpm). Studies indicated that all six products complied with USP dissolution criteria. However, the extent of influence of dissolution conditions on drug release was varied among the products. Distinct dissolution profiles were observed and there was no correlation with disintegration time in certain products. The in vitro dissolution experimentation helped in identifying the discriminatory dissolution conditions and also the formulations that were unaffected with change of dissolution variables. In summary, commercial preparations of carbamazepine vary widely in their dissolution behavior in multi dissolution run experimentation. Identifying this behavior of the products was essential as an in vitro tool for screening a good and a bad formulation.  相似文献   

13.
Various single-cell isolation techniques, including dilution, micromanipulation, flow cytometry, microfluidics, and compartmentalization, have been developed. These techniques can be used to cultivate previously uncultured microbes, to assess and monitor cell physiology and function, and to screen for novel microbiological products. Various other techniques, such as viable staining, in situ hybridization, and those using autofluorescence proteins, are frequently combined with these single-cell isolation techniques depending on the purpose of the study. In this review article, we summarize currently available single-cell isolation techniques and their applications, when used in combination with other techniques, in microbiological and biotechnological studies.  相似文献   

14.
The objective of this work was to examine the feasibility of developing a high-performance computing software system to simulate the United States Pharmacopeia (USP) dissolution apparatus 2 (paddle apparatus) and thus aid in characterizing the fluid hydrodynamics in the method. The USP apparatus was modeled using the hydrodynamic package Fluent. The Gambit program was used to create a “wireframe” of the apparatus and generate the 3-dimensional grids for the computational fluid dynamics solver. The Fluent solver was run on an IBM RS/6000 SP distributed memory parallel processor system, using 8 processors. Configurations with and without a tablet present were developed and examined. Simulations for a liquid-filled vessel at a paddle speed of 50 rpm were generated. Large variations in fluid velocity magnitudes with position in the vessel were evident. Fluid velocity predictions were in good agreement with those previously published, using laser Doppler velocity measurements. A low-velocity domain was evident directly below the center of the rotating paddle. The model was extended to simulate the impact of the presence of a cylindrical tablet in the base of the dissolution vessel. The presence of the tablet complicated the local fluid flow, and large fluid shear rates were evident at the base of the compact. Fluid shear rates varied depending on the tablet surface and the location on the surface and were consistent with the reported asymmetrical dissolution of model tablets. The approach has the potential to explain the variable dissolution results reported and to aid in the design/prediction of optimal dissolution conditions for in vitro-in vivo correlations.  相似文献   

15.
Seaver S 《Cytotherapy》2000,2(1):45-49
The United States Pharmacopeia (USP) has published the first draft of a new information chapter on cell and gene therapy products in January, 2000. The chapter discusses the manufacturing and testing cell and gene therapy products. It is intended for people working in the field as well as for pharmacists and clinicians who would like more information on this subject. This article outlines the background of USP and explains how it became involved with cell and gene therapy and what an information chapter is. It details the subjects covered by the chapter and the philosophy behind the chapter. This draft will be revised based on comments received from the public and then published as a revision subject to further comments before it becomes an official chapter in a supplement to USP 24-NF 19.  相似文献   

16.
Fine particle dose (FPD) is a critical quality attribute for orally inhaled products (OIPs). The abbreviated impactor measurement (AIM) concept simplifies its measurement, provided there is a validated understanding of the relationship with the full resolution pharmacopoeial impactor (PIM) data for a given product. This multi-center study compared fine particle dose determined using AIM and PIM for five dry powder inhaler (DPIs) and two pressurized metered-dose inhaler (pMDI) products, one of which included a valved holding chamber (VHC). Reference measurements of FPDPIM were made by each organization using either the full-resolution Andersen 8-stage non-viable impactor (ACI) or Next Generation Impactor (NGI). FPDAIM was determined for the same OIP(s) with their choice of abbreviated impactor (fast screening impactor (FSI), fast screening Andersen (FSA), or reduced NGI (rNGI)). Each organization used its validated assay method(s) for the active pharmaceutical ingredient(s) (APIs) involved. Ten replicate measurements were made by each procedure. The upper size limit for FPDAIM varied from 4.4 to 5.0 μm aerodynamic diameter, depending upon flow rate and AIM apparatus; the corresponding size limit for FPDPIM was fixed at 5 μm in accordance with the European Pharmacopoeia. The 90% confidence interval for the ratio [FPDAIM/FPDPIM], expressed as a percentage, was contained in the predetermined 85–118% acceptance interval for nine of the ten comparisons of FPD. The average value of this ratio was 105% across all OIPs and apparatuses. The findings from this investigation support the equivalence of AIM and PIM for determination of FPD across a wide range of OIP platforms and measurement techniques.  相似文献   

17.

Introduction

Retail pharmaceutical products are commonly used to treat fever and malaria in sub-Saharan African countries. Small scale studies have suggested that poor quality antimalarials are widespread throughout the region, but nationwide data are not available that could lead to generalizable conclusions about the extent to which poor quality drugs are available in African communities. This study aimed to assess the quality of antimalarials available from retail outlets across mainland Tanzania.

Methods and Findings

We systematically purchased samples of oral antimalarial tablets from retail outlets across 21 districts in mainland Tanzania in 2005. A total of 1080 antimalarial formulations were collected including 679 antifol antimalarial samples (394 sulfadoxine/pyrimethamine and 285 sulfamethoxypyrazine/pyrimethamine), 260 amodiaquine samples, 63 quinine samples, and 51 artemisinin derivative samples. A systematic subsample of 304 products was assessed for quality by laboratory based analysis to determine the amount of the active ingredient and dissolution profile by following the published United States Pharmacopoeia (USP) monogram for the particular tablet being tested. Products for which a published analytical monogram did not exist were assessed on amount of active ingredient alone. Overall 38 or 12.2% of the samples were found to be of poor quality. Of the antifolate antimalarial drugs tested 13.4% were found to be of poor quality by dissolution and content analysis using high-performance liquid chromatography (HPLC). Nearly one quarter (23.8%) of quinine tablets did not comply within the tolerance limits of the dissolution and quantification analysis. Quality of amodiaquine drugs was relatively better but still unacceptable as 7.5% did not comply within the tolerance limits of the dissolution analysis. Formulations of the artemisinin derivatives all contained the stated amount of active ingredient when analysed using HPLC alone.

Conclusions

Substandard antimalarial formulations were widely available in Tanzania at the time of this study. No products were detected that did not contain any amount of the stated active ingredient. Quinine and sulfadoxine/pyrimethamine products were the most widely available and also the most likely to be of poor quality. Substandard products were identified in all parts of the country and were labeled as made by both domestic and international manufacturers. With the expansion of the retail pharmaceutical sector as a delivery channel for antimalarial formulations the need for regular nationwide monitoring of their quality will become increasingly important.  相似文献   

18.
This article investigates enhancement of the dissolution profile of valdecoxib using solid dispersion with PVP. The article also describes the preparation of fast-dissolving tablets of valdecoxib by using a high amount of superdisintegrants. A phase solubility method was used to evaluate the effect of various water-soluble polymers on aqueous solubility of valdecoxib. Polyvinyl pyrrolidone (PVP K-30) was selected and solid dispersions were prepared by the method of kneading. Dissolution studies, using the USP paddle method were performed for solid dispersions of valdecoxib. Infrared (IR) spectroscopy, differential scanning calorimetry (DSC), and x-ray diffractometry (XRD) were performed to identify the physicochemical interaction between drug and carrier, hence its effect on dissolution. Tablets were formulated containing solid dispersion products and compared with commercial products. IR spectroscopy, XRD, and DSC showed no change in the crystal structure of valdecoxib. Dissolution of valdecoxib improved significantly in solid dispersion products (<85% in 5 minutes). Tablets containing solid dispersion exhibited better dissolution profile than commercial tablets. Thus, the solid dispersion technique can be successfully used for improvement of dissolution of valdecoxib. Published: August 18, 2006  相似文献   

19.
20.
The purpose of this study was to evaluate the effect of pH on the dissolution behavior of metaxalone in the marketed product Skelaxin tablets. The dissolution was evaluated using United States Pharmacopeia (USP) dissolution Apparatus 2 and 3 at pHs ranging from 1.5 to 7.4 Results from these studies show that the dissolution of this product is pH dependent. At low pH (simulated gastric fluid, pH 1.5), the dissolution of metaxalone from Skelaxin tablets, was less than 10% over 75 minutes; whereas, dissolution at pH 4.5 showed greater than 90% release in the same time period. These results were consistent for both Apparatus 2 and 3. This suggests that Skelaxin Tablets should be considered a delayed release dosage form.KeyWords: Metaxalone, dissolution, pH dependence, apparatus 3  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号