首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Novel algorithms for radiostereometric (RSA) measurements of the femoral head and metal-backed, hemi-spherical cups of a total hip replacement are presented and evaluated on phantom images and clinical double examinations of 20 patients. The materials were analysed with classical RSA and three novel algorithms: (1) a dual-projection head algorithm using the outline of the femoral head together with markers in the cup; (2) a marker-less algorithm based on measurements of the outline of the femoral head, the cup shell and opening circle of the cup; and (3) a combination of both methods. The novel algorithms improve current, marker-based, RSA measurements, as well as allows studies without marked cups. This opens the possibility of performing wear measurements on larger group of patients, in clinical follow-ups, even retrospective studies. The novel algorithms may help to save patient data in current RSA studies lost due to insufficiently marked cups. Finally, the novel algorithms simplify the RSA procedure and allow new studies without markers, saving time, money, and reducing safety concerns. Other potential uses include migration measurements of re-surfacing heads and measuring spherical sections as implant landmarks instead of markers.  相似文献   

2.
An in vitro radiostereometric analysis (RSA) phantom study of a total knee replacement was carried out to evaluate the effect of implementing two new modifications to the conventional RSA procedure: (i) adding a landmark of the tibial component as an implant marker and (ii) defining an implant-based coordinate system constructed from implant landmarks for the calculation of migration results. The motivation for these two modifications were (i) to improve the representation of the implant by the markers by including the stem tip marker which increases the marker distribution (ii) to recover clinical RSA study cases with insufficient numbers of markers visible in the implant polyethylene and (iii) to eliminate errors in migration calculations due to misalignment of the anatomical axes with the RSA global coordinate system. The translational and rotational phantom studies showed no loss of accuracy with the two new measurement methods. The RSA system employing these methods has a precision of better than 0.05 mm for translations and 0.03° for rotations, and an accuracy of 0.05 mm for translations and 0.15° for rotations. These results indicate that the new methods to improve the interpretability, relevance, and standardization of the results do not compromise precision and accuracy, and are suitable for application to clinical data.  相似文献   

3.
An acoustic transducer design to measure the relative translations and rotations across the knee with no mechanical coupling between the tibia and femur is presented. Platforms attached to femoral and tibial tracking fixtures hold acoustic sources and receivers, respectively. The distance from each source to each receiver is measured by the acoustic transit time and the translations and rotations across the knee joint are computed. For rotations less than 30 deg around the expected operating position, the resolution of the transducer is 0.3 deg; for translations less than 1.5 cm around the expected operating position, the resolution is 0.03 cm. Theoretical error analysis using a Monte Carlo method shows that the uncertainty in the measurement depends on the relative position of the sources and receivers. The analysis predicts the worst case resolution of the transducer as 0.09 cm in translation and 0.6 deg in rotation when the receiver platform is translated 8.0 cm parallel to the source platform. The transducer and fixturing system are demonstrated on a cadaver specimen for applied anterior force and applied internal-external rotation. Errors due to (soft tissue) motion of the transducer relative to the bone during in vivo measurements are assessed on the cadaver specimen. For internal-external rotation the error due to soft tissue motion is a maximum of 0.5 cm in translation and 1.8 deg in rotation. For applied anterior force the error due to soft tissue motion is a maximum of 0.16 cm in translation and 2.7 deg in rotation.  相似文献   

4.
Use of computational models with kinematic boundary conditions to study the knee joint contact behavior for normal and pathologic knee joints depends on an understanding of the impacts of kinematic uncertainty. We studied the sensitivities of tibio-menisco-femoral joint contact behavior to variations in knee kinematics using a finite element model (FEM) with geometry and kinematic boundary conditions derived from sequences of magnetic resonance (MR) images. The MR images were taken before and after axial compression was applied to the knee joint of a healthy subject. A design of experiments approach was used to study the impact of the variation in knee kinematics on the contact outputs. We also explored the feasibility of using supplementary hip images to improve the accuracy of knee kinematics. Variations in knee kinematics (0.25mm in medial-lateral, 0.1mm in anterior-posterior and superior-inferior translations, and 0.1 degrees in flexion-extension and varus-valgus, 0.25 degrees in external-internal rotations) caused large variations in joint contact behavior. When kinematic boundary conditions resulted in close approximations of the model-predicted joint contact force to the applied force, variations in predictions of contact parameters were also reduced. The combination of inferior-superior and medial-lateral translations accounted for over 70% of variations for all the contact parameters examined. The inclusion of hip images in kinematic calculations improved knee kinematics by matching the femoral head position. Our findings demonstrate the importance of improving the accuracy and precision of knee kinematic measurements, especially when utilized as an input for finite element models.  相似文献   

5.
This study aims to quantify and compare the accuracy of traditional radiostereometric analysis (RSA), fluoroscopic RSA (fRSA), and optical tracking systems. Three phantoms were constructed, each having three stainless steel spheres and three reflective markers. One phantom was mounted to the base of a precision cross-slide table, one to the base of a precision rotation table, and the third was mounted to each moveable tabletop. Two dial-gauges, rigidly mounted to the cross-slide table and rotation table, quantified translations and rotations. Two fluoroscopy units placed orthogonally tracked the steel spheres while a four-camera optical motion capture system tracked the reflective markers in three-dimensional space. RSA was performed with both digital radiography and fluoroscopy. Three axes of translation were tested: parallel to one fluoroscopy image, parallel to the other fluoroscopy image, and at approximately 45° to each image. One axis of rotation was tested. Intraclass correlation coefficients indicated excellent agreement between the actual (dial-gauge) and measured translations for all modalities (ICCs>0.99) and excellent agreement between actual and measured rotations for RSA and fRSA (ICCs>0.99). Standard errors of measurement ranged from 0.032 mm and 0.121° for RSA, to 0.040 mm and 0.229° for fRSA, and to 0.109 mm and 0.613° for optical tracking. Differences between actual and measured translations along the 45° axis were significantly smaller than the two parallel axes. These findings suggest that under ideal conditions, accuracy of fRSA is comparable to traditional RSA, and superior to optical tracking. Accuracy is highest when measured at 45° to the fluoroscopy units.  相似文献   

6.
Barn owls exhibit a rich repertoire of head movements before taking off for prey capture. These movements occur mainly at light levels that allow for the visual detection of prey. To investigate these movements and their functional relevance, we filmed the pre-attack behavior of barn owls. Off-line image analysis enabled reconstruction of all six degrees of freedom of head movements. Three categories of head movements were observed: fixations, head translations and head rotations. The observed rotations contained a translational component. Head rotations did not follow Listing’s law, but could be well described by a second-order surface, which indicated that they are in close agreement with Donder’s law. Head translations did not contain any significant rotational components. Translations were further segmented into straight-line and curved paths. Translations along an axis perpendicular to the line of sight were similar to peering movements observed in other animals. We suggest that these basic motion elements (fixations, head rotations, translations along a straight line, and translation along a curved trajectory) may be combined to form longer and more complex behavior. We speculate that these head movements mainly underlie estimation of distance during prey capture.  相似文献   

7.
The range of motion (ROM) of total hip prostheses is influenced by a number of parameters. An insufficient ROM may cause impingement, which may result in subluxation, dislocation or material failure of the prostheses. In a three-dimensional CAD simulation, the position of the centre of rotation and the CCD angle of the stem were investigated. Displacement of the centre of rotation of the femoral head may be due to wear (PE cups) or to the design of the prosthesis (ceramic cups). Stems of widely differing design have been developed and implanted. The results of the present study demonstrate that the ROM is clearly reduced by increasing penetration of the femoral head. At an inclination angle of 45 degrees, a depth of penetration of 2 mm restricts flexion by about 15 degrees, and a depth of penetration of 3 mm by about 30 degrees. At smaller angles of inclination the ROM is reduced and flexion and abduction are associated with an increased risk of impingement. With steeper acetabular cup inclinations, the risk of impingement decreases, but dislocation, the risk of rim fractures (ceramic cups), and wear and penetration rates (PE cups) increase. The CCD angle of the stem should be oriented to the anatomical situation. At high CCD angles (> 135 degrees), flexion is clearly limited, in particular when there is penetration of the femoral head. For modern total hip arthroplasty, prosthetic systems characterised by precise positioning of components, minimum wear, slightly recessed inserts, and appropriate CCD angles should be used.  相似文献   

8.
Ceramic hip resurfacing may offer improved wear resistance compared to metallic components. The study is aimed at investigating the effects of stiffer ceramic components on the stress/strain-related failure mechanisms in the resurfaced femur, using three-dimensional finite element models of intact and resurfaced femurs with varying stem–bone interface conditions. Tensile stresses in the cement varied between 1 and 5 MPa. Postoperatively, 20–85% strain shielding was observed inside the resurfaced head. The variability in stem–bone interface condition strongly influenced the stresses and strains generated within the resurfaced femoral head. For full stem–bone contact, high tensile (151–158 MPa) stresses were generated at the cup–stem junction, indicating risk of fracture. Moreover, there was risk of femoral neck fracture due to elevated bone strains (0.60–0.80% strain) in the proximal femoral neck region. Stresses in the ceramic component are reduced if a frictionless gap condition exists at the stem–bone interface. High stresses, coupled with increased strain shielding in the ceramic resurfaced femur, appear to be major concerns regarding its use as an alternative material.  相似文献   

9.
Numerous techniques have been employed to monitor humeral head translation due to its involvement with several shoulder pathologies. However, most of the techniques were not validated. The objective of this study is to compare the accuracy of manual digitization and contour registration in measuring superior translation of the humeral head. Eight pairs of cadaver scapulae and humerii bones were harvested for this study. Each scapula and humerus was secured in a customized jig that allowed for control of humeral head translations and a vise that permitted rotations of the scapula about three axes. Fluoroscopy was used to take images of the shoulder bones. Scapular orientation was manipulated in different positions while the humerus was at 90° of humeral elevation in the scapular plane. Humeral head translation was measured using the two methods and was compared to the known translation. Additionally, accuracy of the contour registration method to measure 2-D scapular rotations was assessed. The range for the root mean square (RMS) error for manual digitization method was 0.27 mm - 0.43 mm and the contour registration method had a RMS error ranging from 0.18 mm - 0.40 mm. In addition, the RMS error for the scapular angle rotation using the contour registration method was 2.4°. Both methods showed acceptable errors. However, on average, the contour registration method showed lesser measurement error compared to the manual digitization method. In addition, the contour registration method was able to show good accuracy in measuring rotation that is useful in 2-D image analysis.  相似文献   

10.
In cementless total hip arthroplasty, osteoporosis may jeopardize the achievement of immediate stability and lead to migration of anatomically shaped femoral stems. Poor quality of proximal cancellous bone per se may also affect the rate of osseointegration. In a selected group of female total hip arthroplasty patients (mean age 64 years) with unremarkable medical history, intertrochanteric cancellous bone biopsy was taken from the site of stem implantation. Local bone quality, determined by structural μCT imaging and destructive compression testing of the biopsy tissue, was used as the predictor of three-dimensional stem migration determined by radiostereometric analysis (RSA) up to 24 months. The patients exhibited major differences in mechanical properties of the intertrochanteric cancellous bone, which were closely related to the structural parameters calculated from μCT data. Unexpectedly, the major differences observed in the quality of trochanteric cancellous bone had only minor reflections in the RSA migration of the femoral stems. In statistical analysis, the μCT-based bone mineral density quartile (low, middle, high) was the only significant predictor for stem translation at 24 months (p=0.022) but only a small portion (R(2)=0.16) of the difference in translation could be explained by changes in bone mineral density quartile. None of the other parameters investigated predicted stem migration in translation or rotation. In conclusion, poor quality of intertrochanteric cancellous bone seems to contribute to the risk of implant migration less than expected. Probably also the importance of surgical preservation of intertrochanteric cancellous bone has been over-emphasized for osseointegration of cementless stem.  相似文献   

11.
Accurate in vivo measurements methods of wear in total knee arthroplasty are required for a timely detection of excessive wear and to assess new implant designs. Component separation measurements based on model-based Roentgen stereophotogrammetric analysis (RSA), in which 3-dimensional reconstruction methods are used, have shown promising results, yet the robustness of these measurements is unknown. In this study, the accuracy and robustness of this measurement for clinical usage was assessed. The validation experiments were conducted in an RSA setup with a phantom setup of a knee in a vertical orientation. 72 RSA images were created using different variables for knee orientations, two prosthesis types (fixed-bearing Duracon knee and fixed-bearing Triathlon knee) and accuracies of the reconstruction models. The measurement error was determined for absolute and relative measurements and the effect of knee positioning and true seperation distance was determined. The measurement method overestimated the separation distance with 0.1mm on average. The precision of the method was 0.10mm (2*SD) for the Duracon prosthesis and 0.20mm for the Triathlon prosthesis. A slight difference in error was found between the measurements with 0° and 10° anterior tilt. (difference=0.08mm, p=0.04). The accuracy of 0.1mm and precision of 0.2mm can be achieved for linear wear measurements based on model-based RSA, which is more than adequate for clinical applications. The measurement is robust in clinical settings. Although anterior tilt seems to influence the measurement, the size of this influence is low and clinically irrelevant.  相似文献   

12.
Low bone quality may compromise the success of cementless total hip arthroplasty in high-risk patients such as elderly women. Zoledronic acid is a long-lasting antiresorptive agent, which is known to reduce short-term periprosthetic bone loss. However, its effect on femoral stem stability is not well known. Forty-nine female patients with a mean age of 68 years (range, 51–85 years) scheduled to undergo cementless total hip arthroplasty due to osteoarthritis were randomized in this double-blind, placebo-controlled trial to receive a single postoperative infusion of zoledronic acid or placebo. Patients were evaluated for up to four years postoperatively for femoral stem migration measured by radiostereometric analysis, bone mineral density (BMD) measured by dual X-ray absorptiometry, functional recovery, and patient-reported outcome scores. Implant survival was determined at nine years postoperatively. Zoledronic acid did not reduce the femoral stem migration that occurred predominantly during the settling period of the first 3–6 months. Subsequently, all femoral stems were radiographically osseointegrated. Zoledronic acid maintained periprosthetic BMD, while the expected loss of periprosthetic bone during the first 12 months was found in controls. Thereafter, periprosthetic BMD of Gruen zone 7 decreased even in the zoledronic acid group but remained 14.6% higher than that in the placebo group at four years postoperatively. Functional recovery was comparable across the groups. At nine years postoperatively, no revision arthroplasty had been performed. In conclusion, in women at high-risk for low BMD, zoledronic acid had a long-lasting, partially protective effect on periprosthetic bone loss, but the treatment did not enhance the initial femoral stem stability.  相似文献   

13.
The accuracy of digital Roentgen stereophotogrammetric analysis (RSA) was compared to the accuracy of a manually operated RSA system. For this purpose, we used radiographs of a phantom and radiographs of patients. The radiographs of the patients consisted of double examinations of 12 patients that had a tibial osteotomy and of double examinations of 12 patients that received a total hip prosthesis. First, the radiographs were measured manually with an accurate measurement table. Subsequently, the images were digitized by a film scanner at 150 DPI and 300 DPI resolutions and analyzed with the RSA-CMS software. In the phantom experiment, the manually operated system produced significantly better results than the digital system, although the maximum difference between the median values of the manually operated system and the digital system was as low as 0.013 mm for translations and 0.033° for rotations. In the radiographs of the patients, the manually operated system and the digital system produced equally accurate results: no significant differences in translations and rotations were found. We conclude that digital RSA is an accurate, fast, and user friendly alternative for manually operated RSA. Currently, digital RSA systems are being used in a growing number of clinical RSA-studies.  相似文献   

14.
The generation of particulate debris at the taper junction of total hip replacements (THRs), can cause failure of the artificial hip. The taper surfaces of femoral heads and trunnions of femoral stems are generally machined to a certain roughness to enhance fixation. However, the effect of the surface roughness of these surfaces on the fixation, wear and consequently clinical outcomes of the design is largely unknown. In this study, we asked whether a micro-grooved trunnion surface finish (1) improves the fixation and (2) reduces the wear rate at the taper junction of THRs. We used 3D finite element (FE) models of THRs to, firstly, investigate the effect of initial fixation of a Cobalt-Chromium femoral head with a smooth taper surface mated with a Titanium (1) micro-grooved and (2) smooth, trunnion surface finishes. Secondly, we used a computational FE wear model to compare the wear evolution between the models, which was then validated against wear measurements of the taper surface of explanted femoral heads. The fixation at the taper junction was found to be better for the smooth couplings. Over a 7 million load cycle analysis in-silico, the linear wear depth and the total material loss was around 3.2 and 1.4 times higher for the femoral heads mated with micro-grooved trunnions. It was therefore concluded that smooth taper and trunnion surfaces will provide better fixation at the taper junction and reduce the volumetric wear rates.  相似文献   

15.
A leading cause of long-term failure of total knee replacements (TKRs) is osteolysis caused by polyethylene wear particles. The current gold standard for preclinical wear testing of TKRs is mechanical knee simulators. The definition of the femoral center of flexion-extension rotation (CoR) has been identified as one possible source of variability within TKR wear tests, since the femoral curvature varies from distal to posterior. The magnitude of the influence on wear due to changes in location of femoral CoR has not been investigated in depth. During this study, a computational framework utilizing finite element analysis for modelling wear of TKRs was developed and used to investigate the influence of the location of femoral CoR on TKR polyethylene wear during standardized displacement controlled testing (ISO 14243-3:2014). The study was carried out using a 40-point Latin Hypercube Design of Experiments approach. Volumetric wear was highly correlated to femoral CoR in both the superior/inferior and anterior/posterior directions, with a stronger relationship in the superior/inferior direction. In addition, wear scars showing linear penetration were examined, with large differences in simulations at the extreme ends of the sampling region. In this study, it was found that variations in the location of the femoral center of rotation can represent a large source of variability in the preclinical testing and evaluation of the wear performance of total knee replacements. This study represents the first attempt at quantifying the effect on wear of different femoral center of rotations across a large sampling space.  相似文献   

16.
In this study, a new radiostereometric analysis (RSA) calibration cage was developed with the aim of improving the accuracy and precision of RSA. This development consisted of three steps: a numerical simulation technique was first used to design the new cage; a synthetic imaging method was then implemented to predict the performance of the designed cage before it was actually fabricated; and an experimental phantom test was finally conducted to verify the actual performance of the new cage and compare with two currently widely used cages. Accuracy was calculated as the 95% prediction intervals from regression analyses between the measured and actual displacements, and precision was defined as the standard deviation of repeated measurements. The final experimental phantom tests showed that the accuracy and precision of the new calibration cage were improved by about 40% over an existing biplanar cage and by about 70% compared to a uniplanar cage design. This new cage can be used with any skeletal joints, in either static or kinematic examination, which is helpful for the standardization of the RSA application.  相似文献   

17.
The objective of this paper is: to estimate the body mass of the skeletons with the mechanical method (femoral head body mass estimation method--FH) and non-mechanical method (stature/living bi-iliac breadth body mass estimation method--ST/LBIB); to compare the reliability and potential use of results obtained with both methods. The material (46 skeletons, 26 males, 20 females) used in the study came from the medieval burial ground in Cedynia, Poland. Body mass reconstruction according to non-mechanical method was made using equations proposed by Ruff et al. (2005). Body mass estimation based on the mechanical method was calculated using formulas proposed by Ruff et al. (1995). In the mechanical body mass reconstruction method, femoral superoinferior breadth was used. Reconstruction of body weight using the non-mechanical method was based on maximum pelvic breadth and reconstructed body height. The correlation between bi-iliac breadth and femoral head measurements and the correlation between femoral head and reconstructed body height were also calculated. The significance of differences between the body mass of male and female individuals was tested with the Mann-Whitney U-test. The significance of differences between body mass values obtained with the mechanical (FH) and the non-mechanical method (ST/ LBIB) was tested using Pearson's correlation. The same test was used for the calculation of the relationship between bi-iliac breadth and femoral head measurements and between femoral head and reconstructed body height. In contrast to females, in males there is no statistically significant correlation between body mass estimated with the mechanical method (FH) and the non-mechanical method (ST/LBIB). In both sexes there was not statistically significant correlation between bi-iliac breadth and femoral head measurements. Only in the females group the correlation between femoral head and reconstructed body height was statistically significant. It is worth to continue the research. The obtained results would be a valuable contribution to the knowledge on body mass reconstruction methods.  相似文献   

18.
Titanium cermet was successfully synthesized and formed a thin gradient titanium carbide coating on the surface of Ti6Al4V alloy by using a novel sequential carburization under high temperature, while the titanium cermet femoral head was produced. The titanium cermet phase and surface topography were characterized with X-ray diffraction (XRD) and backscattered electron imaging (BSE). And then the wear behavior of titanium cermet femoral head was investigated by using CUMT II artificial joint hip simulator. The surface characterization indicates that carbon effectively diffused into the titanium alloys and formed a hard TiC layer on the Ti6Al4V alloys surface with a micro-porous structure. The artificial hip joint experimental results show that titanium cermet femoral head could not only improve the wear resistance of artificial femoral head, but also decrease the wear of UHMWPE joint cup. In addition, the carburized titanium alloy femoral head could effectively control the UHMWPE debris distribution, and increase the size of UHMWPE debris. All of the results suggest that titanium cermet is a prospective femoral head material in artificial joint.  相似文献   

19.
A new finite element model (FEM) based on an elasto-plastic behavior of ultra high molecular weight polyethylene (UHMWPE) was used to study the wear behavior of UHMWPE acetabular cup, which has a 32 mm diameter femoral head. The model imposed a plastic yield stress of 8 MPa on the UHMWPE so that any stresses beyond this would automatically be redistributed to its neighbor. The FEM model adopted a unique mesh design based on an open cube concept which eliminated the problems of singularities. Wear prediction combined the influences of contact stress, sliding distance and a surface wear coefficient. The new model predicted significantly higher volumetric wear rate (57 mm(3)/yr) well within the average reported clinical values. The model was also used to study the effect of friction and clearance between the acetabular cup and the femoral head. Increase in friction increased the volumetric wear rate but did not appear to affect the linear wear rate, which remained at 0.12 +/- 0.02 mm/yr. The predicted wear was sensitive to clearance. It was found that when the clearance was close to 0 and >0.5mm, severe wear occurred. The best clearance range was between 0.1 and 0.15 mm where the average linear wear rate was 0.1mm/yr and the volumetric wear was 55 mm(3)/yr. The present work indicates the importance of avoiding too tight or too loose a diametrical clearance.  相似文献   

20.
Orthodontic tooth movements are described as the differences between initial and final tooth positions. A computer based method for determination of tooth movements for different treatment methods was developed. A total of 20 casts of the upper jaw of patients treated with tooth positioners or fixed appliances were used as a basis for this study. Tooth movement was analysed on casts before (Ci) and after treatment (Cf). The casts were digitized either with a COMT or 3D laser scanning systems. After digitization, the models were superimposed in the palate by using a surface-surface matching algorithm. Tooth surfaces of the orthodontically moved teeth were segmented and determination of tooth movement was accomplished by matching the moved teeth from Ci to Cf. The resulting transformations delivered three dimensional information on translations and rotations. An accuracy of 0.2 mm in translations and 1 degree in rotations could be demonstrated, showing the different efficiency of treatment schemes.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号