1.
AimsLimited data exist on outcomes in very elderly ICD recipients. We describe outcomes in new ICD and Cardiac Resynchronisation Therapy with Defibrillator (CRT-D) implants in octogenarians at our institution.MethodsPatients aged 80 years and above who underwent de novo ICD or CRT-D implantation from January 2006 to July 2012 were identified. Clinical data were collected from the procedural record, medical and ICD notes. Baseline characteristics were compared using independent sample t test for continuous variables and Fisher’s exact test for categorical variables. Kaplan-Meier curves were constructed.ResultsTen per cent of all new ICD/CRT-D implants were aged 80 years and over. Median age was 83.0 years. Median follow-up was 29 months. Death occurred in 17 (34%). Median time to death was 23 months. Three deaths (6%) occurred within 12 months of ICD implantation. Appropriate therapy (ATP or shock) occurred in 19 (38%). Inappropriate therapy occurred in 6 (12%).Rates of appropriate shocks and inappropriate therapy (shocks and ATP) and significant valvular incompetence were higher amongst deceased patients (P=0.03 OR 5.9 95% CI 1.3-27) and (P=0.02 OR 12 95% CI 1.3-112). Univariate analysis identified diuretic use (P=0.008 95% C.I. 0.05 to 0.63) and appropriate shock (P= 0.025 95% C.I. 1.25 to 26.3) as predictors of mortality.ConclusionOctogenarians make up a small but increasing number of ICD recipients. This study highlights high survival rates at one year with acceptable rates of appropriate and inappropriate device therapy. Ongoing debate regarding the appropriateness of ICD in very elderly patients is warranted.Key words: sudden cardiac death, implantable defibrillators, octogenarians  相似文献   

2.
BackgroundThe patient characteristics, therapy received and outcomes after one or more implantable cardioverter defibrillator (ICD) generator changes from contemporary practice is not well known.MethodsWe conducted a health service evaluation of patients who underwent ICD implantation and generator change. Patients who had generator changes from February 2016 to October 2019 were identified from our database and electronic records were reviewed for patient characteristics, number of generator changes, receipt of therapy and death.ResultsOur database included 88 patients with a generator change. A total of 22 patients (25.0%) received dual chamber ICD, 10 patients (11.4%) received single chamber ICD, 54 patients (61.3%) received cardiac resynchronization therapy defibrillator and 2 patients (2.3%) received subcutaneous ICD. A second generator change occurred in 18 patients and a third generator changes was performed in 6 patients. There were 29 deaths and a follow up period of 9.4 ± 2.9 years. From implant to initial generator change 39 patients had appropriate antitachycardia pacing (ATP), 6 patient had inappropriate ATP, 29 patients had appropriate shocks and 5 patients had an inappropriate shock. Between the 1st and 2nd generator change and the 2nd and 3rd there were no cases of inappropriate ATP or shock. Overall, 42 patients out of the 88 had appropriate therapy (47.7%) and 7 patients had inappropriate therapy (8.0%).ConclusionsMost patients with ICDs do not receive therapy and a minority have inappropriate therapy which typically occur before the first generator change as we observed no inappropriate therapy beyond the first generator change.  相似文献   

3.

Purpose

Based on multiple large clinical trials conducted over the last decades guidelines for implantable cardioverter-defibrillator (ICD) implantations have been evolving. The increase in primary prophylactic ICD implantations challenges us to be critical towards the indications in certain patient populations.

Methods

We retrospectively collected patient characteristics and rates of appropriate and inappropriate ICD therapy, appropriate and inappropriate ICD shock and mortality of all patients who received an ICD in the University Medical Center Utrecht (UMCU) over the years 2006–2011.

Results

A total of 1075 patients were included in this analysis (74 % male, mean age 61 ± 13 years, left ventricular ejection fraction 30 ± 13 %); 61 % had a primary indication and 58 % had ischaemic heart disease. During a mean follow-up period of 31 ± 17 months, 227 of the patients (21 %) received appropriate ICD therapy (149 (14 %) patients received an appropriate ICD shock). Females, patients with a primary prophylactic indication and patients with non-ischaemic heart disease experienced significantly less ICD therapy. Only a few patients (54, 5 %) received inappropriate ICD therapy; 33 (3 %) patients received an inappropriate ICD shock. Fifty-five patients died within one year after ICD implantation and were therefore, in retrospect, not eligible for ICD implantation.

Conclusion

Our study confirms the benefit of ICD implantation in clinical practice. Nevertheless, certain patients experience less benefit than others. A more patient-tailored risk stratification based on electrophysiological parameters would be lucrative to improve clinical benefit and cost-effectiveness.  相似文献   

4.

Introduction

Survival benefit from ICD implantation is relatively low in primary prevention patients. Better patient selection is important to maintain maximum survival benefit while reducing the number of unnecessary implants. Microvolt T-wave alternans (MTWA) is a promising risk marker. In this study, we aimed to evaluate the predictive value of MTWA in ICD patients.

Methods and results

This study was a substudy of the Twente ICD Cohort Study (TICS). Patients with ischaemic or non-ischaemic left ventricular dysfunction who received an ICD following current ESC guidelines were eligible for inclusion. Exercise-MTWA was performed and classified as non-negative or negative. The primary endpoint was the composite of mortality and appropriate shock therapy. Analysis was performed in 134 patients (81 % male, mean age 62 years, mean ejection fraction 26.5 %). MTWA was non-negative in 64 %. There was no relation between non-negative MTWA testing and mortality and/or appropriate shock therapy (all p-values >0.15). Due to clinical conditions, 24 % were ineligible for testing. These patients experienced the highest risk for mortality (p < 0.01).

Conclusion

Non-negative MTWA testing did not predict mortality and/or appropriate shock therapy. Furthermore, MTWA testing is not feasible in a large percentage of patients. These ineligible patients experience the highest risk for mortality.  相似文献   

5.

Background

Current algorithms and device morphology templates have been proposed in current Implantable Cardioverter-Defibrillators (ICDs) to minimize inappropriate therapies (ITS), but this has not been completely successful.

Aim

Assess the impact of a deliberate strategy of using an atrial lead implant with standardized parameters; based on all current ICD discriminators and technologies, on the burden of ITS.

Method

A retrospective single-centre analysis of 250 patients with either dual chamber (DR) ICDs or biventricular ICDs (CRTDs) over a (41.9 ± 27.3) month period was performed. The incidence of ITS on all ICD and CRTD patients was chronicled after the implementation of standardized programming.

Results

39 events of anti-tachycardial pacing (ATP) and/or shocks were identified in 20 patients (8% incidence rate among patients). The total number of individual therapies was 120, of which 34% were inappropriate ATP, and 36% were inappropriate shocks. 11 patients of the 250 patients received ITS (4.4%). Of the 20 patients, four had ICDs for primary prevention and 16 for a secondary prevention. All the episodes in the primary indication group were inappropriate, while seven patients (43%) of the secondary indication group experienced inappropriate therapies.

Conclusions

The burden of ITS in the population of patients receiving ICDs was 4.4% in the presence of atrial leads. The proposed rationalized programming criteria seems an effective strategy to minimize the burden of inappropriate therapies and will require further validation.  相似文献   

6.
Implantable Cardioverter Defibrillator (ICD) implantation is the only established therapy for primary or secondary prevention of sudden cardiac death in patients with Hypertrophic Cardiomyopathy (HCM). Ineffectiveness of shock therapy for the termination of potentially fatal ventricular arrhythmias in ICD recipients is rare in the presence of appropriate arrhythmia detection by the device. We report the case of a 48-year-old woman with HCM and a single chamber ICD, who received five inefficient high-energy (35 Joules) shocks for the termination of an appropriately detected episode of Ventricular Tachycardia (VT). The episode was safely terminated with a subsequent application of Antitachycardia Pacing (ATP) by the device. At the following ICD control, an acceptable defibrillation threshold was detected.  相似文献   

7.

Introduction

Arrhythmogenic right ventricular cardiomyopathy (ARVC) is a rare genetically transmitted disease prone to ventricular arrhythmias. We therefore investigated the clinical, echocardiographical and electrophysiological predictors of appropriate implantable cardioverter defibrillator (ICD) therapy in patients with ARVC.

Methods

A retrospective analysis was performed in 26 patients (median age of 40 years at diagnosis, 21 males and 5 females) with ARVC who underwent ICD implantation.

Results

Over a median (range) follow-up period of 10 (2.7, 37) years, appropriate ICD therapy for ventricular arrhythmias was documented in 12 (46%) out of 26 patients. In all patients with appropriate ICD therapy the ICD was originally inserted for secondary prevention. Median time from ICD implantation to ICD therapy was 9 months (range 3.6, 54 months). History of heart failure was a significant predictor of appropriate ICD therapy (p = 0.033). Left ventricular disease involvement (p = 0.059) and age at implantation (p = 0.063) were borderline significant predictors. Patients with syncope at time of diagnosis were significantly less likely to receive ICD therapy (p = 0.02). Invasive electrophysiological testing was not significantly associated with appropriate ICD therapy.

Conclusion

In our cohort of patients with ARVC, history of heart failure was a significant predictor of appropriate ICD therapy, whereas left ventricular involvement and age at time of ICD implantation were of borderline significance. These predictors should be tested in larger prospective cohorts to optimize ICD therapy in this rare cardiomyopathy.  相似文献   

8.
T-wave oversensing can cause inappropriate implantable cardioverter-defibrillator (ICD) therapies that are difficult to correct. Remote monitoring allows follow-up of ICD patients without visiting the hospital and can help in early detection of any malfunctions. We describe the case of a patient who experienced inappropriate antitachycardia pacing therapy due to T-wave oversensing; the problem was promptly detected by remote monitoring and corrected by device reprogramming.  相似文献   

9.

Purpose

Since several large trials have proven the effectiveness of implantable cardioverter-defibrillators (ICDs) in patients with left ventricular dysfunction, disadvantages have become more apparent. As the prognosis of patients with cardiovascular diseases is improving, assessment of ICD patients and re-evaluation of the current guidelines is mandatory. We aimed to evaluate differences in mortality and occurrence of (in)appropriate shocks in ICD patients with coronary artery disease (CAD) or dilated cardiomyopathy (DCM).

Methods

In a large teaching hospital, all consecutive patients with systolic dysfunction due to CAD or DCM who received an ICD with and without resynchronisation therapy, were collected in a database.

Results

A total of 320 consecutive patients (age 67 ± 10 years) were classified as CAD patients and 178 (63 ± 11 years) as DCM patients. Median follow-up was 40 months (interquartile range [IQR] 23─57 months). All–cause mortality was 14 % (CAD 15 % vs DCM 13 %). Appropriate shocks occurred in 13 % of all patients (CAD 15 % vs DCM 11 %, p = 0.12) and inappropriate shocks occurred in 10 % (CAD 8 % vs DCM 12 %, p = 0.27). Multivariate analysis demonstrated impaired left ventricular ejection fraction, QRS >120, age ≥75 years and low estimated glomerular filtration rate as predictors for all-cause mortality. Predictors for inappropriate shocks were permanent and paroxysmal atrial fibrillation.

Conclusion

Mortality rates were similar in patients with CAD and DCM who received an ICD. Furthermore, no differences were found in the occurrence of appropriate and inappropriate ICD interventions between these patient groups.  相似文献   

10.
The ventricular tachycardia (VT) monitoring zone in implantable cardioverter defibrillators (ICDs) is usually programmed to detect slow VTs. However, it is not well known whether programming this zone can affect the ICD arrhythmia redetection or confirmation criteria. We report two cases of inappropriate ICD shocks due to the programming of a slow VT monitoring zone in the same device model.  相似文献   

11.
The delivery of implantable cardioverter defibrillator (ICD) therapy is sophisticated and requires the programming of over 100 settings. Physicians tailor these settings with the intention of optimizing ICD therapeutic efficacy, but the usefulness of this approach has not been studied and is unknown. Empiric programming of settings such as anti-tachycardia pacing (ATP) has been demonstrated to be effective, but an empiric approach to programming all VT/VF detection and therapy settings has not been studied. A single standardized empiric programming regimen was developed based on key strategies with the intention of restricting shock delivery to circumstances when it is the only effective and appropriate therapy. The EMPIRIC trial is a worldwide, multi-center, prospective, one-to-one randomized comparison of empiric to physician tailored programming for VT/VF detection and therapy in a broad group of about 900 dual chamber ICD patients. The trial will provide a better understanding of how particular programming strategies impact the quantity of shocks delivered and facilitate optimization of complex ICD programming.  相似文献   

12.

Background

Patients eligible for cardiac resynchronisation therapy (CRT) have an indication for primary prophylactic implantable cardioverter defibrillator (ICD) therapy. However, response to CRT might influence processes involved in arrhythmogenesis and therefore change the necessity of ICD therapy in certain patients.

Method

In 202 CRT-defibrillator patients, the association between baseline variables, 6-month echocardiographic outcome (volume response: left ventricular end-systolic volume decrease < ≥15 % and left ventricular ejection fraction (LVEF) ≤ >35 %) and the risk of first appropriate ICD therapy was analysed retrospectively.

Results

Fifty (25 %) patients received appropriate ICD therapy during a median follow-up of 37 (23–52) months. At baseline ischaemic cardiomyopathy (hazard ratio (HR) 2.0, p = 0.019) and a B-type natriuretic peptide level > 163 pmol/l (HR 3.8, p < 0.001) were significantly associated with the risk of appropriate ICD therapy. After 6 months, 105 (52 %) patients showed volume response and 51 (25 %) reached an LVEF > 35 %. Three (6 %) patients with an LVEF > 35 % received appropriate ICD therapy following echocardiography at ± 6 months compared with 43 patients (29 %) with an LVEF ≤ 35 % (p = 0.001). LVEF post-CRT was more strongly associated to the risk of ventricular arrhythmias than volume response (LVEF > 35 %, HR 0.23, p = 0.020).

Conclusion

Assessing the necessity of an ICD in patients eligible for CRT remains a challenge. Six months post-CRT an LVEF > 35 % identified patients at low risk of ventricular arrhythmias. LVEF might be used at the time of generator replacement to identify patients suitable for downgrading to a CRT-pacemaker.  相似文献   

13.

Background

Implantable cardioverter-defibrillators (ICDs) are widely used for the prevention of sudden cardiac death. At present, both clinical benefit and cost-effectiveness of ICD therapy in primary prevention patients are topics of discussion, as only a minority of these patients will eventually receive appropriate ICD therapy.

Methods/design

The DO-IT Registry is a nationwide prospective cohort with a target enrolment of 1,500 primary prevention ICD patients with reduced left ventricular function in a setting of structural heart disease. The primary outcome measures are death and appropriate ICD therapy for ventricular tachyarrhythmias. Secondary outcome measures are inappropriate ICD therapy, death of any cause, hospitalisation for ICD related complications and for cardiovascular reasons. As of December 2016, data on demographic, clinical, and ICD characteristics of 1,468 patients have been collected. Follow-up will continue up to 24 months after inclusion of the last patient. During follow-up, clinical and ICD data are collected based on the normal follow-up of these patients, assuming ICD interrogations take place every six months and clinical follow-up is once a year. At baseline, the mean age was 66 (standard deviation [SD] 10) years and 27% were women.

Conclusion

The DO-IT Registry represents a real-world nationwide cohort of patients receiving ICDs for primary prevention of sudden cardiac death with reduced left ventricular function in a setting of structural heart disease. The registry investigates the efficacy of the current practice and aims to develop prediction rules to identify subgroups who will not (sufficiently) benefit from ICD implantation and to provide results regarding costs and budget impact of targeted supply of primary preventions ICDs.
  相似文献   

14.
Heart failure is a life-threatening disease with a growing incidence in the Netherlands. This growing incidence is related to increased life expectancy, improvement of survival after myocardial infarction and better treatment options for heart failure. As a consequence, the costs related to heart failure care will increase. Despite huge improvements in treatment, the prognosis remains unfavourable with high one-year mortality rates. The introduction of implantable devices such as implantable cardioverter defibrillators (ICD) and cardiac resynchronisation therapy (CRT) has improved the overall survival of patients with chronic heart failure. However, after ICD implantation for primary prevention in heart failure a high percentage of patients never have appropriate ICD discharges. In addition 25–50?% of CRT patients have no therapeutic effect. Moreover, both ICDs and CRTs are associated with malfunction and complications (e.?g. inappropriate shocks, infection). Last but not least is the relatively high cost of these devices. Therefore, it is essential, not only from a clinical but also from a socioeconomic point of view, to optimise the current selection criteria for ICD and CRT. This review focusses on the role of cardiac sympathetic hyperactivity in optimising ICD selection criteria. Cardiac sympathetic hyperactivity is related to fatal arrhythmias and can be non-invasively assessed with 123I-meta-iodobenzylguanide (123I-mIBG) scintigraphy. We conclude that cardiac sympathetic activity assessed with 123I-mIBG scintigraphy is a promising tool to better identify patients who will benefit from ICD implantation.  相似文献   

15.
With the introduction of the implantable cardioverter defibrillator (ICD), patients can be protected against sudden cardiac death (SCD) due to ventricular arrhythmia (VA). Guidelines have been drawn up for selecting patients for primary and secondary prophylaxis. However, most ICD recipients today who receive an ICD for primary prevention will not experience a life-threatening VA requiring antitachypacing or shock therapy. Better risk stratification is desirable with efficacy, costs and complication rate in mind. An overview is presented of widely accepted and potentially valuable risk markers and the role they may play in better identifying candidates for ICD therapy. (Neth Heart J 2009;17:101–6.)  相似文献   

16.
Implantable cardioverter defibrillator (ICD) is often advised for secondary prevention of sudden cardiac death. Inappropriate shocks from ICD is uncommon but can seriously affect the quality of life. One of the reasons for inappropriate ICD shock is loose set screw, which may remain undetected by device interrogation and/or fluoroscopy. A 55-year lady presented with multiple inappropriate shocks few hours after an ICD implantation. The discrepancy between near field (NF, tip to ring) and far field (FF, Can to RV coil) signals helped us to suspect noise related to loose set screw, as the underlying problem. Re-exploration of the pocket had to be performed as the last resort to confirm the diagnosis and rectify the problem.  相似文献   

17.
We report a patient with an implantable cardioverter defibrillator (ICD) for arrhythmogenic right ventricular dysplasia (ARVD) who received inappropriate shocks for atrioventricular node reentry tachycardia (AVRNT). Patient had multiple shocks for tachycardia with EGM characteristics of very short VA interval and CL of 300 msec. An electrophysiologic (EP) study reproducibly induced typical AVNRT with similar features. The slow AV nodal pathway ablation resolved the ICD shocks. Despite increasingly sophisticated discrimination algorithms available in modern ICDs, the ability to differentiate SVT from VT can be challenging. Our patient received inappropriate shocks for AVNRT. When device interrogation alone is not conclusive, an EP study may be necessary to determine the appropriate therapeutic course.  相似文献   

18.

Background

Timely detection of atrial fibrillation (AF) in implantable cardioverter defibrillator (ICD) patients is clinically important for prevention of AF-related complications and inappropriate shocks. Patients with coronary artery disease (CAD) and a dual or triple chamber ICD show a high incidence of device-detected AF. Whether CAD patients with a single chamber ICD carry a similar risk for device-detected AF remains unknown.

Study design

The INDICO AF trial is an investigator-initiated, multicentre, observational study evaluating the incidence of subclinical AF (SCAF) in CAD patients who will receive a single chamber ICD as primary prevention for sudden cardiac death (SCD). Fifty patients will receive a single chamber ICD with an integrated RR interval based AF detection algorithm. In combination with remote monitoring, rhythm data will be collected monthly. The primary endpoint is the incidence of SCAF at 1 year of follow-up; secondary endpoints include time until 10 and 20% of the patients have a first episode of SCAF. All patients in whom SCAF is detected will be invited for an outpatient visit and will receive adequate anticoagulation treatment when appropriate according to the CHA2DS2-VASc score and current guidelines.

Conclusion

The INDICO AF trial will quantify the incidence of SCAF in patients with an ICD and CAD. The study will underscore the clinical value of SCAF detection in single chamber ICD patients using remote patient monitoring and may improve patient care. This trial is registered at trialregister.nl with trial NTR6910.
  相似文献   

19.
Hypertrophic cardiomyopathy’s (HCM) association with sudden cardiac death is well recognised. The risk of sudden cardiac death is known to increase when there is a history of unexplained syncope, abnormal blood pressure response during exercise, severe left ventricular hypertrophy or a family history of unexplained death.Implantable Cardioverter Defibrillator (ICD) implantation has been widely used for primary and secondary prevention of sudden cardiac death (SCD) in people with HCM. Subcutaneous ICD (S-ICD) therapy has been developed to overcome some of the problems associated with the transvenous leads used in conventional ICDs.In this article, we report the use of S-ICD in a patient with HCM and multiple risk factors for sudden cardiac death, this device had to be extracted due to recurrent inappropriate shocks caused by over sensing of atrial flutter and failure to treat a VT episode. We are not aware of any reports of inappropriate shocks caused by atrial flutter in people with a S-ICD.  相似文献   

20.
The implantable cardioverter defibrillator (ICD) has significantly improved survival in patients with an increased risk of sudden cardiac death (SCD). The wearable cardioverter defibrillator (WCD) is an alternative to the ICD in patients with a transient ICD indication or those in whom an ICD temporarily cannot be implanted. We describe here the technical details of the WCD and report three patients who were treated with a WCD in an outpatient setting. The WCD allowed the cardiac condition of two patients to improve to such an extent that permanent ICD implantation was deemed unnecessary. This new form of therapy may result in significant cost reduction, avoidance of unnecessary ICD implantation, and increased patient satisfaction.  相似文献   