首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Using mathematical simulation of motor unit potentials (MUPs), detected by a point and rectangular plate electrode, we have shown that the muscle tissue does not act like a low-pass frequency filter on MUPs. Depending on the electrode type and its longitudinal position, the relative weight of the terminal phases (reflecting the excitation extinction) in MUPs and thus of high frequencies in the MUP power spectrum, increase with the MU depth. Therefore, high-pass filtering or differentiating signals detected neither monopolarly nor bipolarly could eliminate the cross-talk produced by high frequency components of MUPs from deep MUs. Such methods could be effective against the main components but not against the MUP leading edge and terminal phases. To reduce the cross-talk, position of the detecting electrodes should correspond to anatomy of muscles producing the cross-talk. Monopolar electrode should be located above the ends of the muscles. Cross-talk of the muscles located beyond the muscle of interest could be higher than that produced above the end-plate of deep muscles. On the contrary, under detection by a longitudinal bipolar electrode, the cross-talk is much smaller above the end-plate region or beyond deep muscles. The cross-talk is the greatest above the ends of the deep muscles.  相似文献   

2.
The purpose of this paper was to evaluate the effects of the longitudinal single differential (LSD), the longitudinal double differential (LDD) and the normal double differential (NDD) spatial filters, the electrode shape, the inter-electrode distance (IED) on non-Gaussianity and non-linearity levels of simulated surface EMG (sEMG) signals when the maximum voluntary contraction (MVC) varied from 10% to 100% by a step of 10%. The effects of recruitment range thresholds (RR), the firing rate (FR) strategy and the peak firing rate (PFR) of motor units were also considered.A cylindrical multilayer model of the volume conductor and a model of motor unit (MU) recruitment and firing rate were used to simulate sEMG signals in a pool of 120 MUs for 5 s. Firstly, the stationarity of sEMG signals was tested by the runs, the reverse arrangements (RA) and the modified reverse arrangements (MRA) tests. Then the non-Gaussianity was characterised with bicoherence and kurtosis, and non-linearity levels was evaluated with linearity test.The kurtosis analysis showed that the sEMG signals detected by the LSD filter were the most Gaussian and those detected by the NDD filter were the least Gaussian. In addition, the sEMG signals detected by the LSD filter were the most linear. For a given filter, the sEMG signals detected by using rectangular electrodes were more Gaussian and more linear than that detected with circular electrodes. Moreover, the sEMG signals are less non-Gaussian and more linear with reverse onion-skin firing rate strategy than those with onion-skin strategy. The levels of sEMG signal Gaussianity and linearity increased with the increase of the IED, RR and PFR.  相似文献   

3.
Recently, high-density surface EMG electrode grids and multi-channel amplifiers became available for non-invasive recording of human motor units (MUs). We present a way to decompose surface EMG signals into MU firing patterns, whereby we concentrate on the importance of two-dimensional spatial differences between the MU action potentials (MUAPs). Our method is exemplified with high-density EMG data from the vastus lateralis muscle of a single subject. Bipolar and Laplacian spatial filtering was applied to the monopolar raw signals. From the single recording in this subject six different simultaneously active MUs could be distinguished using the spatial differences between MUAPs in the direction perpendicular to the muscle fiber direction. After spike-triggered averaging, 125-channel two-dimensional MUAP templates were obtained. Template-matching allowed tracking of all MU firings. The impact of spatial information was measured by using subsets of the MUAP templates, either in parallel or perpendicular to the muscle fiber direction. The use of one-dimensional spatial information perpendicular to the muscle fiber direction was superior to the use of a linear array electrode in the longitudinal direction. However, to detect the firing events of the MUs with a high accuracy, as needed for instance for estimation of firing synchrony, two-dimensional information from the complete grid electrode appears essential.  相似文献   

4.
Motor unit action potentials (MUAPs) of brachial biceps were simulated. A simulated MUAP was obtained as a sum of single fibre action potentials (SFAPs) from all the muscle fibres of a motor unit (MU). The influence of the following factors on MUAP shape for different kinds of recording electrode was studied: fibre density, neuromuscular jitter, temporal dispersion and electrode displacements. The simulation confirms that typical MUAPs recorded with needle electrodes from muscles of low fibre density such as brachial biceps are usually triphasic. Increased fibre density produces MUAPs of more complex shape and higher amplitude. Normal neuromuscular jitter is responsible for the variability of shape of subsequent potentials from the same MU as well as for electromyographic shimmer. Pathologic (increased) jitter makes the shapes of subsequent potentials unrecognizable. The influence of temporal dispersion is interconnected with other factors but rather of minor importance. The simulation shows how big changes in MUAP shape can be expected due to electrode displacements during single experiment or during estimation of MU territory.  相似文献   

5.
Decline in amplitude of EMG signals and in the rate of counts of intramuscularly recorded spikes during fatigue is often attributed to a progressive reduction of the neural drive only. As a rule, alterations in intracellular action potential (IAP) are not taken into account. To test correctness of the hypothesis, the effect of various discharge frequency patterns as well as changes in IAP shape and muscle fibre propagation velocity (MFPV) on the spike amplitude-frequency histogram of intramuscular interference EMG signals were simulated and analyzed. It was assumed that muscle was composed of four types of motor units (MUs): slow-twitch fatigue resistant, fast-twitch fatigue resistant, fast intermediate, and fast fatigable. MFPV and IAP duration at initial stage before fatigue as well as their changes differed for individual MU types. Fatigability of individual MU types in normal conditions as well as in the case of ischaemic or low oxygen conditions due to restricted blood flow was also taken into account. It was found that spike amplitude-frequency histogram is poorly sensitive to MU firing frequency, while it is highly sensitive to IAP profile lengthening. It is concluded that spike amplitude-frequency analysis can hardly provide a correct measure of MU rate-coding pattern during fatigue.  相似文献   

6.
Capabilities of amplitude and spectral methods for information extraction from interference EMG signals were assessed through simulation and preliminary experiment. Muscle was composed of 4 types of motor units (MUs). Different hypotheses on changes in firing frequency of individual MUs, intracellular action potential (IAP) and muscle fibre propagation velocity (MFPV) during fatigue were analyzed. It was found that changes in amplitude characteristics of interference signals (root mean square, RMS, or integrated rectified value, IEMG) detected by intramuscular and surface electrodes differed. RMS and IEMG of surface detected interference signals could increase even under MU firing rate reduction and without MU synchronisation. IAP profile lengthening can affect amplitude characteristics more significantly than MU firing frequency. Thus, an increase of interference EMG amplitude is unreliable to reflect changes in the neural drive. The ratio between EMG amplitude and contraction response can hardly characterise the so-called 'neuromuscular efficiency'. The recently proposed spectral fatigue indices can be used for quantification of interference EMG signals. The indices are practically insensitive to MU firing frequency. IAP profile lengthening and decrease in MFPV enhanced the index value, while recruitment of fast fatigable MUs reduced it. Sensitivity of the indices was higher than that of indices traditionally used.  相似文献   

7.
The role of electrode materials in the reduction of halothane and oxygen mixtures at rotating and stationary electrodes is considered. Halothane is found to be electroactive within the available electrode-potential range on silver and on gold. Double potential step experiments are considered in order to isolate the individual halothane and oxygen signals. A double integration, single potential step technique is evaluated for the quantitative simultaneous measurements of oxygen and halothane on gold.The influence of electrode purity is discussed in terms of a reaction mechanism and electrode output error.  相似文献   

8.
Sinderby, C., S. Friberg, N. Comtois, and A. Grassino.Chest wall muscle cross talk in the canine costal diaphragm electromyogram. J. Appl. Physiol.81(5): 2312-2327, 1996.The present paper describes the influenceof cross talk from the abdominal and intercostal muscles on the caninediaphragm electromyogram (EMG). The diaphragm EMG was recorded withbipolar surface electrodes placed on the costal portion of thediaphragm (abdominal side), aligned in the fiber direction, andpositioned in a region with a relatively low density of motor endplates. The results indicated that cross talk may occur in thediaphragm EMG, especially during conditions of loaded breathing andlight general anesthesia. The cross-talk signals showed characteristicsthat were entirely different from the diaphragm EMG. Although thediaphragm EMG was typical for signals recorded with electrodes alignedin the fiber direction, the cross-talk signals were characteristic ofthose obtained with electrode pairs not aligned in the direction of themuscle fibers. Alterations in electrode positioning, interelectrodedistance, and/or electrode surface area cannot guarantee theelimination of cross-talk signals, whereas spinal anesthesia at a highthoracic level will paralyze the sources of the cross talk and henceeliminate the cross-talk signals. By taking advantage of thedifferences in EMG signal characteristics for the diaphragm EMG andcross-talk signals, an index that has the capability to detect crosstalk was developed.

  相似文献   

9.
Long-distance dispersal research: building a network of yellow brick roads   总被引:8,自引:2,他引:6  
This special issue of Diversity and Distributions presents six papers that contribute to the assembly of a general research agenda for studying long‐distance dispersal (LDD) across a variety of taxonomic groups (e.g. birds, fish, aquatic invertebrates and plants), ecosystems (e.g. terrestrial and marine ecosystems, wetlands and grasslands) and thematic fields (e.g. biological transport, marine biology, biogeochemistry and biodiversity conservation). This editorial emphasizes the need to develop a network integrating different research approaches (‘yellow brick roads’) to address the great challenge (‘finding the end of the rainbow’) of quantifying, understanding and predicting LDD and its implications. I review the key avenues for future research suggested in the special issue contributions, and stress the critical importance of properly considering the spatial and temporal scales relevant to the process and system of interests. I propose combining absolute and proportional definitions of LDD as a default practice in any investigation of LDD processes. When LDD is defined primarily by an absolute critical distance that characterizes key feature(s) of the system of interest, a quantitative assessment of the proportion of dispersal events expected to move beyond this critical threshold distance should also be provided. When LDD is defined primarily by a certain small fraction of dispersal events that travel longer than all others, an estimate of the absolute distance associated with this high percentile at the tail of the dispersal curve should also be added.  相似文献   

10.
The linear electrode array: a useful tool with many applications.   总被引:4,自引:0,他引:4  
In this review we describe the basic principles of operation of linear electrode arrays for the detection of surface EMG signals, together with their most relevant current applications. A linear array of electrodes is a system which detects surface EMG signals in a number of points located along a line. A spatial filter is usually placed in each point for signal detection, so that the recording of EMG signals with linear arrays corresponds to the sampling in one spatial direction of a spatially filtered version of the potential distribution over the skin. Linear arrays provide indications on motor unit (MU) anatomical properties, such as the locations of the innervation zones and tendons, and the fiber length. Such systems allow the investigation of the properties of the volume conductor and its effect on surface detected signals. Moreover, linear arrays allow to estimate muscle fiber conduction velocity with a very low standard deviation of estimation (of the order of 0.1-0.2 m/s), thus providing reliable indications on muscle fiber membrane properties and their changes in time (for example with fatigue or during treatment). Conduction velocity can be estimated from a signal epoch (global estimate) or at the single MU level. In the latter case, MU action potentials are identified from the interference EMG signals and conduction velocity is estimated for each detected potential. In this way it is possible, in certain conditions, to investigate single MU control and conduction properties with a completely non-invasive approach. Linear arrays provide valuable information on the neuromuscular system properties and appear to be promising tools for applied studies and clinical research.  相似文献   

11.
Wet tropical forests are among the most diverse ecosystems on Earth and can host several hundreds of tree species per hectare. To maintain such diversity, the community must contain large numbers of relatively rare species rather than be dominated by a few very common trees, as is often the case in temperate forests. Explaining the mechanisms preventing dominance by common species has been a major task of tropical forest ecology. One of the most promising mechanisms is negative density dependence (NDD) of tree abundance driven by pests, including fungal diseases (‘pest pressure’). NDD entails that the chance of survival of a sapling increases with the distance from a mature tree of the same species, thus preventing species from becoming locally dominant. Curiously, the strength of NDD is negatively correlated with abundance, meaning that tree species that are more common generally show weaker NDD (Comita et al. 2010 ). Interactions between plants and soil pathogens have been shown to play an important role in NDD (Klironomos 2002 ), and rare species are apparently more strongly affected (Mangan et al. 2010 ). However, the genetic mechanisms underlying this phenomenon have remained obscure. In this issue of Molecular Ecology, Marden et al. ( 2017 ) suggest that reduced diversity of the genes involved in pathogen recognition (Resistance genes or R genes) could explain why NDD is stronger in locally rare species.  相似文献   

12.
Changes accompanying long-lasting intermittent muscle contractions (30%–50% of the maximal) were investigated by tracing the activity of 38 motor units (MU) of the human biceps brachii muscle recorded from fine-wire branched electrodes. The motor task was a continuous repetition of ramp-and-hold cycles of isometric flexion contractions. During ramp-up phases a significant decline in recruitment thresholds was found with no changes in the discharge pattern. During ramp-down phases the unchanged mean value of derecruitment thresholds during the task was accompanied by increased duration of the last two interspike intervals (ISI). These findings would suggest that during fatigue development the main compensatory mechanism during ramp-up contractions is space coding while for ramp-down contractions it is rate coding. During the steady-state phases the mean value of ISI, as well as the firing variability, had increased by the end of the task in most of the MU investigated . In addition 17 recruited MU were also investigated. These units revealed a lower initial discharge rate and a faster decrease in the mean discharge rate with the development of fatigue. The gradual reduction of the recruitment threshold of already active MU and the recruitment of new units demonstrated an increased excitability of the motorneuron pool during fatigue. A typical recruitment pattern (a first short ISI followed by a long one) was observed during ramp-up contractions in units active from the very beginning of the task, as well as during sustained contractions at the onset of the stable discharge of the additionally recruited MU. Accepted: 23 September 1997  相似文献   

13.
Zorović M 《PloS one》2011,6(10):e26843
During mating, males and females of N. viridula (Heteroptera: Pentatomidae) produce sex- and species-specific calling and courtship substrate-borne vibratory signals, grouped into songs. Recognition and localization of these signals are fundamental for successful mating. The recognition is mainly based on the temporal pattern, i.e. the amplitude modulation, while the frequency spectrum of the signals usually only plays a minor role. We examined the temporal selectivity for vibratory signals in four types of ascending vibratory interneurons in N. viridula. Using intracellular recording and labelling technique, we analyzed the neurons' responses to 30 pulse duration/interval duration (PD/ID) combinations. Two response arrays were created for each neuron type, showing the intensity of the responses either as time-averaged spike counts or as peak instantaneous spike rates. The mean spike rate response arrays showed preference of the neurons for short PDs (below 600 ms) and no selectivity towards interval duration; while the peak spike rate response arrays exhibited either short PD/long ID selectivity or no selectivity at all. The long PD/short ID combinations elicited the weakest responses in all neurons tested. No response arrays showed the receiver preference for either constant period or duty cycle. The vibratory song pattern selectivity matched the PD of N. viridula male vibratory signals, thus pointing to temporal filtering for the conspecific vibratory signals already at level of the ascending interneurons. In some neurons the responses elicited by the vibratory stimuli were followed by distinct, regular oscillations of the membrane potential. The distance between the oscillation peaks matched the temporal structure of the male calling song, indicating a possible resonance based mechanism for signal recognition.  相似文献   

14.
Clay NK  Nelson T 《The Plant cell》2002,14(11):2707-2722
The formation of the venation pattern in leaves is ideal for examining signaling pathways that recognize and respond to spatial and temporal information, because the pattern is two-dimensional and heritable and the resulting veins influence the three-dimensional spatial organization of the surrounding differentiating leaf cell types. We identified a provascular/procambial cell-specific gene that encodes a Leu-rich repeat receptor kinase, which we named VASCULAR HIGHWAY1 (VH1). A change in the expression domain and level of VH1 marks the transition from an uncommitted provascular state to a committed procambial state in early vascular development. The coding sequence, expression pattern, and transgenic phenotypes together suggest that VH1 transduces extracellular spatial and temporal signals into downstream cell differentiation responses in provascular/procambial cells.  相似文献   

15.
The aim of this study was to investigate changes in experimentally recorded M-waves with progressive motor unit (MU) activation induced by transcutaneous electrical stimulation with different pulse waveforms. In 10 subjects, surface electromyographic signals were detected with a linear electrode array during electrically elicited contractions of the biceps brachii muscle. Three different monophasic waveforms of 304-μs duration were applied to the stimulation electrode on the main muscle motor point: triangular, square, and sinusoidal. For each waveform, increasing stimulation current intensities were applied in 10 s (frequency: 20 Hz). It was found that: (a) the degree of MU activation, as indicated by M-wave average rectified value, was a function of the injected charge and not of the stimulation waveform, and (b) MUs tended to be recruited in order of increasing conduction velocity with increasing charge of transcutaneous stimulation. Moreover, the subjects reported lower discomfort during the contractions elicited by the triangular waveform with respect to the others. Since subject tolerance to the stimulation protocol must be considered as important as MU recruitment in determining the effectiveness of neuromuscular electrical stimulation (NMES), we suggest that both charge and waveform of the stimulation pulses should be considered relevant parameters for optimizing NMES protocols.  相似文献   

16.
Motor unit (MU) activity pattern was examined in the right-hand extensor digitorum communis muscle (EDC) during standardised finger movements simulating actual computer mouse tasks. Intramuscular recordings were performed with a quadripolar needle electrode. Nine women performed four lifts of their right-hand index finger, middle finger or both as well as a number of double clicks. Additionally, the subjects performed contra lateral activity with their left-hand fingers and for three subjects recordings were also obtained during an interview with no physical activity. Besides the expected close coupling of MU activity with finger movement, activity was observed in three different situations with no physical requirements. Attention related activity was found before or after performance of the finger movement task, contra lateral activity in right EDC during left-hand finger tasks, and activity during mental activity without any finger movements involved. A relatively large number of doublet occurrences suggest they are a natural part of the activation pattern during performance of the rapid finger movement required to perform an efficient double click on the computer mouse.  相似文献   

17.
IntroductionCardiac contraction significantly degrades quality and quantitative accuracy of gated myocardial perfusion SPECT (MPS) images. In this study, we aimed to explore different techniques in motion-compensated temporal processing of MPS images and their impact on image quality and quantitative accuracy.Material and method50 patients without known heart condition underwent gated MPS. 3D motion compensation methods using Motion Freezing by Cedars Sinai (MF), Log-domain Diffeomorphic Demons (LDD) and Free-Form Deformation (FFD) were applied to warp all image phases to fit the end-diastolic (ED) phase. Afterwards, myocardial wall thickness, myocardial to blood pool contrast, and image contrast-to noise ratio (CNR) were measured in summed images with no motion compensation (NoMC) and compensated images (MF, LDD and FFD). Total Perfusion Defect (TPD) was derived from Cedars-Sinai software, on the basis of sex-specific normal limits.ResultLeft ventricle (LV) lateral wall thickness was reduced after applying motion compensation (p < 0.05). Myocardial to blood pool contrast and CNR in compensated images were greater than NoMC (p < 0.05). TPD_LDD was in good agreement with the corresponding TPD_MF (p = 0.13).ConclusionAll methods have improved image quality and quantitative performance relative to NoMC. LDD and FFD are fully automatic and do not require any manual intervention, while MF is dependent on contour definition. In terms of diagnostic parameters LDD is in good agreement with MF which is a clinically accepted method. Further investigation along with diagnostic reference standards, in order to specify diagnostic value of each technique is recommended.  相似文献   

18.
Two-component signal transduction systems enable bacteria to sense and respond to a wide range of environmental stimuli. Sensor histidine kinases transmit signals to their cognate response regulators via phosphorylation. The faithful transmission of information through two-component pathways and the avoidance of unwanted cross-talk require exquisite specificity of histidine kinase-response regulator interactions to ensure that cells mount the appropriate response to external signals. To identify putative specificity-determining residues, we have analyzed amino acid coevolution in two-component proteins and identified a set of residues that can be used to rationally rewire a model signaling pathway, EnvZ-OmpR. To explore how a relatively small set of residues can dictate partner selectivity, we combined alanine-scanning mutagenesis with an approach we call trajectory-scanning mutagenesis, in which all mutational intermediates between the specificity residues of EnvZ and another kinase, RstB, were systematically examined for phosphotransfer specificity. The same approach was used for the response regulators OmpR and RstA. Collectively, the results begin to reveal the molecular mechanism by which a small set of amino acids enables an individual kinase to discriminate amongst a large set of highly-related response regulators and vice versa. Our results also suggest that the mutational trajectories taken by two-component signaling proteins following gene or pathway duplication may be constrained and subject to differential selective pressures. Only some trajectories allow both the maintenance of phosphotransfer and the avoidance of unwanted cross-talk.  相似文献   

19.
20.
The flat interface nerve electrode (FINE) has demonstrated significant capability for fascicular and subfascicular stimulation selectivity. However, due to the inherent complexity of the neuromuscular skeletal systems and nerve–electrode interface, a trajectory tracking motion control algorithm of musculoskeletal systems for functional electrical stimulation using a multiple contact nerve cuff electrode such as FINE has not yet been developed. In our previous study, a control system was developed for multiple-input multiple-output (MIMO) musculoskeletal systems with little prior knowledge of the system. In this study, more realistic computational ankle/subtalar joint model including a finite element model of the sciatic nerve was developed. The control system was tested to control the motion of ankle/subtalar joint angles by modulating the pulse amplitude of each contact of a FINE placed on the sciatic nerve. The simulation results showed that the control strategy based on the separation of steady state and dynamic properties of the system resulted in small output tracking errors for different reference trajectories such as sinusoidal and filtered random signals. The proposed control method also demonstrated robustness against external disturbances and system parameter variations such as muscle fatigue. These simulation results under various circumstances indicate that it is possible to take advantage of multiple contact nerve electrodes with spatial selectivity for the control of limb motion by peripheral nerve stimulation even with limited individual muscle selectivity. This technology could be useful to restore neural function in patients with paralysis.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号