首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
BACKGROUND: Preoperative autologous donation is one way to decrease a patient''s exposure to allogeneic blood transfusion. This study was designed to determine patients'' perceptions about the autologous blood donation process and their experiences with transfusion. METHODS: To assess patient perception, a questionnaire was administered a few days before surgery to patients undergoing elective cardiac and orthopedic surgery in a Canadian teaching hospital. All patients attending the preoperative autologous donation clinic during a 10-month period were eligible. A convenience sample of patients undergoing the same types of surgery who had not predonated blood were selected from preadmission clinics. Patient charts were reviewed retrospectively to assess actual transfusion practice in all cases. RESULTS: A total of 80 patients underwent cardiac surgery (40 autologous donors, 40 nondonors) and 73 underwent orthopedic surgery (38 autologous donors, 35 nondonors). Of the autologous donors, 75 (96%) attended all scheduled donation appointments, 73 (93%) said that they were "very likely" or "likely" to predonate again, and 75 (96%) said that they would recommend autologous donation to others. There was little difference in preoperative symptoms between the autologous donors and the nondonors, although the former were more likely than the latter to report that their overall health had remained the same during the month before surgery (30 [75%] v. 21 [52%] for the cardiac surgery patients and 30 [79%] v. 18 [51%] for the orthopedic surgery patients). When the autologous donors were asked what they felt their chances would have been of receiving at least one allogeneic blood transfusion had they not predonated, the median response was 80%. When they were asked what their chances were after predonating their own blood, the median response was 0%. The autologous donors were significantly less likely to receive allogeneic blood transfusions (6 [15%] for cardiac surgery and 3 [8%] for orthopedic surgery) than were the nondonors (14 [35%] for cardiac surgery and 16 [46%] for orthopaedic surgery). They were, however, more likely to receive any transfusion (autologous or allogeneic) than were the nondonors (25 [63%] v. 14 [35%] for cardiac surgery and 31 [81%] v. 16 [46%] for orthopedic surgery). INTERPRETATION: Patients who underwent preoperative autologous blood donation were positive about the experience and did not report more symptoms than patients who did not donate blood preoperatively. Autologous donors overestimated their chances of receiving allogeneic blood transfusions had they not predonated and underestimated their chances after they had predonated. They were less likely to receive allogeneic transfusions, but more likely to receive any type of transfusion, than were patients who did not predonate.  相似文献   

2.
Several methods have been found to be successful in reducing the need for allogeneic transfusion among the patients undergoing total hip replacement. The purpose of this prospective study was to analyse the quality and evaluate the effect of postoperative autotransfusion on the need for allogeneic transfusion following total hip replacement. The prospective study was performed in two groups of patients undergoing total hip replacement. Before the operative procedure all patients in both groups predonated two doses of autologous blood. In GROUP 1. the system for postoperative collection and transfusion of shed blood was used. In GROUP 2. the patients underwent total hip replacement without blood salvage system. Standard suction collection sets were used postoperatively. In this group shed blood was not transfused to the patients. The samples of preoperative donated autologus blood, allogeneic blood and postoperative collected autologous blood were analysed for number of red cells, hemoglobin, hematocrit, platelets, white blood cells, values of potassium, sodium, free hemoglobin and acid base status. The postoperatively blood salvage significantly reduced the use of allogeneic transfusion among patients managed with total hip replacement (allogeneic transfusion received 12% patients in Group 1 and 80% patients in Group 2; p<0.001). The values of red blood cells are significantly lower in postoperative collected autotransfusion blood compared with preoperative collected autologous blood and allogeneic blood (p<0.001). The values of potassium and acid base status were in normal range in postoperatively collected autotransfusion blood. These values in preoperatively collected autologous blood and allogeneic blood were out of normal range; (p<0.001). In addition to reducing the risk of complications that are associated with allogeneic transfusion, postoperative blood salvage may offer benefits including reducing the need for allogeneic blood. Our study confirmed that postoperative collection and transfusion of drainaged blood is simple and safe method that significantly reduce the need for allogeneic transfusion in patients underwent total hip replacement. The blood collected and transfused postoperatively has lower values of red blood cells and normal values of potassium and acid base balance. The transfusion of this blood caused no complications in our patients.  相似文献   

3.
The transfusion laboratories of 32 cardiothoracic surgical centres for adults were surveyed to determine the donor blood requirement for open heart surgery in the United Kingdom. Details of the transfusion practice and the use of blood conservation techniques were sought from a representative senior cardiac anaesthetist at each centre. Suitable data were received from 24 transfusion laboratories (75%) and 29 anaesthetists (90%). The mean (SD) blood use was 5.07 (1.53) units per operation. Seven centres routinely transfused fresh frozen plasma to all patients postoperatively. Experience with autologous deposit (three centres), "cell separators" (four centres), and the reinfusion of shed mediastinal blood (four centres) was limited. Prebypass phlebotomy for postbypass reinfusion (14 centres) and the infusion of residual oxygenator blood (27 centres) were the conservation techniques most commonly applied. In only nine centres was a postoperative normovolaemic anaemia to a haemoglobin concentration of less than 100 g/l accepted. Applying blood conservation techniques more widely would help to maintain blood supplies and reduce morbidity and mortality related to transfusion.  相似文献   

4.
The widespread use of blood transfusion in major surgical procedures has led to concern about the immunosuppressive effect of transfusion on patients with underlying malignancy. Transfusion may also suppress the host response to infection. The cellular mechanisms of transfusion-associated immunosuppression may involve macrophage prostaglandin E2 (PGE2) in modulating the host response to cancer and infection. We previously observed that the transfusion of blood increased PGE2 production by unstimulated macrophages. To investigate this PGE2 associated immunosuppression, we studied the effect of transfusion of rats using a physiological stimulus of macrophage PGE2 production, bacterial endotoxin. In the same macrophages, we analysed intracellular oxidative activity. Both allogeneic and syngeneic blood transfusion were associated with increased PGE2 release by macrophages. This stimulation of PGE2 increased with duration of storage of blood. A similar effect of serum indicated that a humoral factor was involved. Endotoxin (50 ng/ml–500 μg/ml) stimulated PGE2 production in all transfused subjects. The lowest endotoxin concentration gave proportionately the greatest stimulation. Oxidative activity was down-regulated in macrophages of transfused rats, supporting an immunosuppressive role of PGE2 within the macrophage. An effect of surgery on the oxidative response was also detected.  相似文献   

5.
6.
To better understand the reasons for the increasing use of platelet concentrate in Canada, we undertook a 4-month study of platelet concentrate transfusion in six eastern Ontario hospitals in 1985. A total of 4801 units of platelet concentrate were transfused on 687 occasions to 303 patients; the average number of transfusions per patient was 2.3, the average number of units per transfusion 7.0 and the average number of units per patient 15.8. The cardiovascular service used the largest proportion of units (28%), aortocoronary bypass grafting being the most common procedure. The mean pretransfusion platelet count for the medical and oncology services was about 30.0 X 10(9)/L, compared with 155.5 X 10(9)/L for the cardiovascular service. An increment in platelet count 1 hour after transfusion was noted with 238 (75%) of the transfusions for which the data were available; the average increment was 3.4 X 10(9)/L per unit of platelet concentrate transfused. When the data for patients who did not respond were excluded, the average increment was 6.9 X 10(9)/L. Single-donor platelet concentrate was requested for only half of the transfusions to which no response was detected. The current medical literature supports the appropriate use of platelet concentrate in patients with thrombocytopenia due to chemotherapy, but prophylactic platelet transfusion for patients undergoing cardiovascular bypass procedures is being questioned. We advise continued surveillance of the use of these products and re-evaluation of the aims of platelet transfusion therapy.  相似文献   

7.
The profit to be gained by testing Danish blood donors for hepatitis B surface antigen (HBsAg) with a third generation technique instead of the currently used immunoelectrophoresis was investigated by additional screening of 48 750 blood units by radioimmunoassay three weeks after donation. Twenty nine units were positive for HBsAg on radioimmunoassay (0.059%). Only six of these were found by immunoelectrophoresis (0.012%). Most of the 23 donors positive on radioimmunoassay and negative on immunoelectrophoresis were healthy carriers of HBsAg (20) or had asymptomatic chronic liver disease (two). One donor had acute hepatitis B. Fifteen of the 23 blood units were transfused. The 15 recipients were monitored biochemically and serologically for up to nine months. One recipient developed fulminant hepatitis B, three developed acute hepatitis B, and one became a healthy carrier of HBsAg. All these patients had received blood from healthy carriers of HBsAg. Two recipients were immunised against HBsAg, and in one patient no seroconversion was observed. The remaining recipients died soon after transfusion or were protected by antibodies to HBsAg that had been present before the transfusion. Testing of Danish blood donors using a third generation technique identified a substantial number of donors positive for HBsAg overlooked by immunoelectrophoresis. Most of these donors were healthy carriers of HBsAg. Blood taken from such carriers is highly infectious when transfused, probably because of the large amount of material transmitted.  相似文献   

8.
Transfusion affects the immune response to renal transplantation and may be associated with recurrence of various human neoplasms. Data from patients with colonic, rectal, cervical, and prostate tumours showed an association between transfusion of any amount of whole blood or larger amounts of red blood cells at the time of surgery and later recurrence of cancer. Recipients of one unit of whole blood had a significantly higher incidence of recurrence (45%) than recipients of a single unit of red cells (12%) (p = 0.03). Recipients of two units of whole blood also had a higher rate of recurrence (52%) than those receiving two units of red cells (23%) (p = 0.03). Recipients of any amount of whole blood had similar recurrence rates (38-52%). Recipients of four or more units of red blood cells had a higher rate of recurrence (55%) than those receiving three or fewer units of red blood cells (20%) (p = 0.005). Mortality due to cancer in patients receiving three or fewer units of red blood cells (2%) was similar to that in patients who did not have transfusions (7%) and significantly lower than that observed in patients receiving three or fewer units of whole blood (20%) (p = 0.003). A proportional hazards risk analysis showed that transfusion of any whole blood or more than three units of red blood cells was significantly associated with earlier recurrence and death due to cancer. These data support an association between transfusion and recurrence of cancer. They also suggest that some factor present in greater amounts in whole blood, such as plasma, may contribute to the increased risk of recurrence in patients who have undergone transfusion. Until the questions raised by retrospective studies of cancer recurrence and transfusion can be answered by prospective interventional trials with washed red blood cells, red blood cells should be transfused to patients with cancer in preference to whole blood when clinically feasible.  相似文献   

9.
The first nationwide nucleic acid amplification testing (NAT) for hepatitis B virus (HBV), hepatitis C virus (HCV), and human immunodeficiency virus type 1 (HIV-1) of voluntarily donated blood after serological pre-screening and before release of cellular components and plasma for fractionation was implemented by the Japanese Red Cross Blood Transfusion Services. From February 1, 2000 to April 30, 2001, specimens from 6,805,010 units of serologically negative donation were screened in minipools of 50 samples within 24 hr after blood donation by NAT using multiplex HBV/HCV/HIV-1 reagent for blood transfusion including short shelf-life platelets. Among them, 112 HBV DNA-positives, 25 HCV RNA positives and 4 HIV-1 RNA positives were screened out and we could prevent transfusion of these NAT positive units. Subtypes/genotypes of HBV DNA, adr/C, adw/A, adw/B, adw/C, ayr/C and ayw/D were found and adr/C was predominant. A total of 61.6 % of them (69/112) were negative by overnight EIA. Sixth three of HBV NAT-positive samples carried virus loads less than 10(4) copies/mL and 92.1 % of them (58/63) were negative by overnight EIA. The virus growth curves of HBV in 6 cases obtained by retrospective and prospective follow-up study showed exponential straight lines in the early stage of serological window periods and the log times of HBV growth (10 fold increase) in serological window period were between 4.6 and 7.6 days. NAT screening with highly sensitive reagents in pool of specimens is useful to exclude blood units with low level of HBV and HBV mutants from blood transfusion.  相似文献   

10.
W F Brien  R J Butler  M J Inwood 《CMAJ》1989,140(7):812-815
As part of a quality assurance program a retrospective audit of transfusion practices for packed red blood cells, fresh frozen plasma and albumin was undertaken with predetermined criteria in a general teaching hospital. Of 520 transfusion episodes with 1218 units of packed red blood cells given to 297 patients 88% were considered appropriate; of 106 episodes with 405 units of fresh frozen plasma given to 83 patients 90% were deemed appropriate; and of 187 episodes with 320 units of albumin given to 99 patients 64% were considered appropriate. The results of this audit, when compared with those of other surveys of blood use in a similar population, suggest that pretransfusion approval of requested components would reduce the number of inappropriate transfusions.  相似文献   

11.
ObjectiveTo collect population based information on transfusion of red blood cells.DesignProspective observational study over 28 days.SettingHospital blood banks in the north of England (population 2.9 million).ParticipantsAll patients who received a red cell transfusion during the study period. Data completed by hospital blood bank staff.ResultsThe destination of 9848 units was recorded (97% of expected blood use). In total 9774 units were transfused: 5047 (51.6%) units were given to medical patients, 3982 (40.7%) to surgical patients, and 612 (6.3%) to obstetric and gynaecology patients. Nearly half (49.3%) of all blood is given to female recipients, and the mean age of recipients of individual units was 62.7 years. The most common surgical indications for transfusion were total hip replacement (4.6% of all blood transfused) and coronary artery bypass grafting (4.1%). Haematological disorders accounted for 15.5% of use. Overall use was 4274 units per 100 000 population per year.ConclusionIn the north east of England more than half of red cell units are transfused for medical indications. Demand for red cell transfusion increases with age. With anticipated changes in the age structure of the population the demand for blood will increase by 4.9% by 2008.

What is already known on this topic

There have been no systematic population based surveys on use of red cells in the United KingdomStudies in France and the United States have shown that more than half of transfused red cells go to surgical patients

What this study adds

In the north of England over half of red cells are given for medical indicationsRates of red cell transfusion rise steeply with advancing ageSmall increases in the number of elderly people will have large effects on demand  相似文献   

12.
Summary Studies from several centers have shown an immunosuppressive effect of surgical procedures, whilst others have shown blood transfusion in association with cancer surgery to have an adverse effect on ultimate prognosis. We have previously demonstrated enhanced growth of tumor metastases, in rats following allogeneic blood transfusion and surgery. Polyadenylic-polyuridylic acid (poly A-poly U) has been reported to stimulate immune responses. In this report, we have investigated the effectiveness of poly A-poly U as an adjuvant to blood transfusion and surgical procedures in BN rats bearing artificial lung metastases. Significantly reduced tumor growth was observed, following poly A-poly U adjuvant treatment. These results lead to serious contemplation of the use of this drug as adjuvant therapy in blood transfused and surgically treated patients.  相似文献   

13.
The shelf life of 60,000 units of whole blood and red cell concentrates in the blood center were analysed before delivering to hospitals as well as the transfusion age of 18,000 units in relation to the stock-size and the outdated units. The mean transfusion age of whole blood units and red blood cell concentrates amounted to 11 to 12 days and 16 to 17 days, respectively. The shelf life of blood transfused within 24 hours after collection was 1.6% and 3.8% transfused within 48 hours according to the total number of whole blood and red blood cell concentrates. Washed red cell concentrates were prepared from buffy coat-free resuspended red cell concentrates on an average at the 7th day of storage. A high stock-size of about 1,000 units rather than of 600 units in the blood center increased the shelf life and also the number of outdated units from less than 0.5% up to more than 3%.  相似文献   

14.
OBJECTIVE: To determine the cost, from a societal perspective, of blood transfusion in Canada. STUDY DESIGN: Cost-structure analysis. SETTING: Data were collected from eight hospitals and from six blood centres operated by the Canadian Red Cross Society in four provinces. OUTCOME MEASURES: Costs associated with four stages of transfusion-- collection, production, distribution and delivery--in 1933 were assessed. Costs were divided into the following categories; personnel, purchases, external services, overhead, donors'' time, patients'' time (for autologous transfusion), wastage and infection. RESULTS: The mean overall cost of a transfusion performed on an inpatient basis was $210 per unit of red blood cells for an allogeneic transfusion and $338 per unit of blood for an autologous transfusion. The mean cost of an allogeneic transfusion performed on an outpatient basis was $280 per unit of red blood cells. CONCLUSION: The costs determined in this study can be used in future studies comparing the cost-effectiveness of allogeneic transfusion with that of alternative methods.  相似文献   

15.
16.
W A Ghali  A Palepu  W G Paterson 《CMAJ》1994,150(9):1449-1454
OBJECTIVE: To assess current red blood cell (RBC) transfusion practices and to determine the potential impact of implementing recently published guidelines on RBC transfusion from the American College of Physicians (ACP). DESIGN: Medical chart review. SETTING: A 219-bed teaching hospital in Kingston, Ont. PARTICIPANTS: All patients over 12 years of age who received RBC transfusions in March 1992. MAIN OUTCOME MEASURES: Need for transfusion according to the ACP guidelines and the number of blood units ordered for each transfusion. RESULTS: A total of 55 patients received 170 RBC units. According to the ACP guidelines 94 (55.3%) of the units were judged unnecessary. The departments of Surgery and Internal Medicine did not differ significantly in the number of unnecessary units (56.4% v. 52.8%). Among the surgical subspecialties, unnecessary transfusion was most common in the orthopedics service (73.5%, p < 0.05). Blood was most frequently ordered 2 units at a time (51.8% of units). Transfusion in normovolemic, hemodynamically stable patients with anemia and unnecessary multiple-unit transfusions were the most common violations of the ACP guidelines. CONCLUSIONS: According to the ACP guidelines, there was significant unnecessary blood use in the hospital surveyed. The guidelines provide a useful framework for assessing transfusion practices but may require further refinement to apply to a broader spectrum of clinical settings.  相似文献   

17.
ObjectiveTo assess the effectiveness of two mechanical methods of blood conservation in reducing the need for allogeneic red blood cells or coagulation products during cardiac surgery.DesignRandomised controlled trial.SettingRegional cardiac centre in a teaching hospital in Southampton.Participants263 adults aged 18-80 years undergoing elective coronary artery bypass surgery entered the study, of whom 252 completed the trial. All patients received routine perioperative care. Patients were allocated to one of three treatment groups: intraoperative cell salvage, intraoperative cell salvage with acute perioperative normovolaemic haemodilution, or no mechanical blood conservation. There were 84 patients in each group.ResultsOf the patients in the intraoperative cell salvage group, 26 were given a transfusion of allogeneic blood, compared with 43 in the control group (odds ratio 0.43 (95% confidence interval 0.23 to 0.80)). The mean number of units of allogeneic blood transfused per patient in the intraoperative cell salvage group was 0.68 units (SD=1.55), compared with 1.07 (1.56) units in the control group. 32 of the patients in the intraoperative cell salvage group were given any blood product, compared with 47 in the control group (odds ratio 0.47 (0.25 to 0.89); P=0.019). Combining acute perioperative normovolaemic haemodilution with intraoperative cell salvage conferred no additional benefits.ConclusionsAn intraoperative cell salvage device should be used in elective coronary artery bypass grafting. Pharmacological strategies may achieve further reductions in blood transfusions. Yet further reductions in blood transfusions could be achieved if the lower safe limit of haemoglobin concentration in patients undergoing cardiac surgery were known.

What is already known on this topic

Patients undergoing elective coronary artery bypass surgery often need a blood transfusionRecent meta-analyses have shown that the mechanical blood conservation techniques of intraoperative cell salvage and acute perioperative normovolaemic haemodilution may reduce the need for transfusion, but flawed methods in trials mean that clear evidence in cardiac surgery is lacking

What this study adds

Intraoperative cell salvage significantly reduces the number of patients needing an allogeneic blood transfusionCombining acute perioperative normovolaemic haemodilution with intraoperative cell salvage does not confer any additional benefit  相似文献   

18.
Developing a practical means of reducing alloimmunization in chronically transfused patients would be of significant clinical benefit. Immunocamouflaging red blood cells (RBCs) by membrane grafting of methoxypoly(ethylene glycol) (mPEG) may reduce the risk of allo-immunization. The results of this study showed that antibody recognition of non-ABO antigens was significantly reduced in an mPEG-dose- and polymer size-dependent manner, with higher molecular weight mPEGs providing better immunoprotection. Furthermore, in vivo immunogenicity was significantly reduced in mice serially transfused with mPEG-modified xenogeneic (sheep; sRBCs), allogeneic (C57Bl/6), or syngeneic (Balb/c) RBCs. Following a primary transfusion of sRBCs, mice receiving mPEG-sRBCs showed a >90% reduction in anti-sRBC IgG antibody levels. After two transfusions, mice receiving mPEG-sRBCs showed reductions of >80% in anti-sRBC IgG levels. Importantly, mPEG-modified autologous cells did not induce neoantigens or an immune (IgG or IgM) response. These data suggest that the global immunocamouflage of RBCs by polymer grafting may provide a safe and cost-effective means of reducing the risk of alloimmunization.  相似文献   

19.
Transfusion induces blood donor-specific suppressor cells   总被引:5,自引:0,他引:5  
Transfusion with blood from the organ donor before transplantation can prolong the survival of renal allografts in the rat. To determine if the beneficial effect of preoperative blood transfusion was due to the generation of donor-specific suppressor cells, in vivo and in vitro adoptive transfer experiments were performed. Lymphoid cells were harvested from transfused and untreated rats. These cells were then either (1) transferred to lightly irradiated (200 R) syngeneic hosts which were subsequently challenged with a kidney allograft (in vivo assay) or (2) titrated as regulator cells into naive unidirectional MLC such that the regulator and responder populations were syngeneic. In the LEW-RT1 to DA-RT1av1 strain combination, the adoptive transfer of thoracic duct lymph (TDL) or lymph node (LN) cells (5 x 10(7) to 7.5 x 10(7) cells) from DA animals transfused with LEW blood, 7 days previously into syngeneic (DA), lightly irradiated (200 R) hosts resulted in the indefinite survival of LEW kidney allografts. The phenomenon was blood donor-specific and dose-dependent. In contrast the adoptive transfer of spleen cells (10(7) to 10(8] from blood transfused hosts 7 days after transfusion had no effect on renal allograft survival. In vitro the addition of LN or TDL regulator cells, harvested from DA rats transfused with LEW blood, to a unidirectional MLC (DA responders, LEW stimulators) resulted in a significant depression of the proliferative response when compared with the proliferation of these same cells without the addition of these regulator cells or with the addition of LN or TDL regulator cells from a DA rat transfused with third party (PVG-RT1c) blood. The depression of the proliferative response observed in vitro, was blood donor specific. When LN or TDL regulator cells from a DA rat transfused with PVG-RT1c blood were added to a unidirectional MLC between DA responders and PVG stimulators, a significant depression in the proliferative response was observed. These in vitro findings were confirmed in two other strain combinations (LEW-PVG, and DA-PVG). Thus a single blood transfusion results in the induction of donor-specific suppressor cells detectable both in vivo and in vitro 7 days after transfusion in some but not all lymphoid compartments.  相似文献   

20.
Anti-HIV test results of the Red Cross Blood Transfusion Service of Lower Saxony from 1 June 1985 to 31 July 1986 inclusive were analysed retrospectively. Nine out of 70,936 donors who had not donated blood before 1 June 1985 (first-time donors) and 9 out of 261,231 donors who had donated blood before this date (repeating donors) were found anti-HIV confirmed positive at the time of the first blood donation during the study period. The prevalence of HIV antibody in first-time donors was significantly higher than in repeating donors (p less than 0.01). It was concluded that some members of risk groups used blood donation to obtain an anti-HIV test result. One out of 30,300 blood donations was confirmed anti-HIV positive. The results of this study justify the transfusion of blood donations that are reactive only in the initial ELISA test.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号