首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Multidimensional liquid-based separation techniques are described for maximizing the resolution of the enormous number of peptides generated upon tryptic digestion of proteomes, and hence, reduce the spatial and temporal complexity of the sample to a level that allows successful mass spectrometric analysis. This review complements the previous contribution on unidimensional high performance liquid chromatography (HPLC). Both chromatography and electrophoresis will be discussed albeit with reversed-phase HPLC (RPLC) as the final separation dimension prior to MS analysis.  相似文献   

2.
Proteomics is a commonly used approach that can provide insights into complex biological systems. The cochlear sensory epithelium contains receptors that transduce the mechanical energy of sound into an electro-chemical energy processed by the peripheral and central nervous systems. Several proteomic techniques have been developed to study the cochlear inner ear, such as two-dimensional difference gel electrophoresis (2D-DIGE), antibody microarray, and mass spectrometry (MS). MS is the most comprehensive and versatile tool in proteomics and in conjunction with separation methods can provide an in-depth proteome of biological samples. Separation methods combined with MS has the ability to enrich protein samples, detect low molecular weight and hydrophobic proteins, and identify low abundant proteins by reducing the proteome dynamic range. Different digestion strategies can be applied to whole lysate or to fractionated protein lysate to enhance peptide and protein sequence coverage. Utilization of different separation techniques, including strong cation exchange (SCX), reversed-phase (RP), and gel-eluted liquid fraction entrapment electrophoresis (GELFrEE) can be applied to reduce sample complexity prior to MS analysis for protein identification.  相似文献   

3.
The complexity of the human proteome, already enormous at the organism level, increases further in the course of the proteome analysis due to in vitro sample evolution. Most of in vitro alterations can also occur in vivo as post-translational modifications. These two types of modifications can only be distinguished a posteriori but not in the process of analysis, thus rendering necessary the analysis of every molecule in the sample. With the new software tool ModifiComb applied to MS/MS data, the extent of modifications was measured in tryptic mixtures representing the full proteome of human cells. The estimated level of 8-12 modified peptides per each unmodified tryptic peptide present at >or=1% level is approaching one modification per amino acid on average. This is a higher modification rate than was previously thought, posing an additional challenge to analytical techniques. The solution to the problem is seen in improving sample preparation routines, introducing dynamic range-adjusted thresholds for database searches, using more specific MS/MS analysis using high mass accuracy and complementary fragmentation techniques, and revealing peptide families with identification of additional proteins only by unfamiliar peptides. Extensive protein separation prior to analysis reduces the requirements on speed and dynamic range of a tandem mass spectrometer and can be a viable alternative to the shotgun approach.  相似文献   

4.
The analysis of neurochemicals from the brain represents a challenge for current analytical techniques due to a variety of factors, such as compositional complexity, limited amounts of sample and endogenous inferences. Advances in mass spectrometry (MS) provide great opportunities for the sensitive measurement of neurochemicals, offering benefits including simple sample preparation, broad capability for analysis of diverse compounds and rich structural information of analytes. Until recently, however, limited numbers of studies have reported on the analysis of small molecular neurochemicals, such as classical neurotransmitters, in part due to the difficulties in separation of polar molecules by using current chromatography techniques with MS-compatible conditions. By contrast, MS has become an indispensable tool for neuropeptide analysis , offering tremendous potential in the discovery of novel signaling peptides and biomarkers. This review covers recent advances in MS-based neurochemical analysis , including a comparison with related detection techniques, chromatographic separation and neuropeptide discovery. Issues relating to in vivo sample collection and sample preparation are discussed. To provide a wider view of the capability of MS in basic neuroscience and clinical research, we discuss MS-based neurochemical analysis conducted in different animal models and humans. We specifically highlight perspectives for the use of MS for brain functional studies and drug discovery in nonhuman primates.  相似文献   

5.
Mass spectrometry (MS) is an established technology in drug metabolite analysis and is now expanding into endogenous metabolite research. Its utility derives from its wide dynamic range, reproducible quantitative analysis, and the ability to analyze biofluids with extreme molecular complexity. The aims of developing mass spectrometry for metabolomics range from understanding basic biochemistry to biomarker discovery and the structural characterization of physiologically important metabolites. In this review, we will discuss the techniques involved in this exciting area and the current and future applications of this field.  相似文献   

6.
Multi-dimensional liquid phase based separations in proteomics   总被引:7,自引:0,他引:7  
This review covers recent developments towards the implementation of multi-dimensional (MuD) liquid phase based systems for proteome investigations. Although two-dimensional polyacrylamide gel electrophoresis (2D-PAGE) has been used as a standard approach in proteomics, its drawbacks including the limited dynamic range and molecular mass range, together with lack of on-line integration with biological mass spectrometery (Bio-MS) have limited its widespread use and applications in proteomics. In the meantime, various liquid-phase based multi-dimensional separation techniques have been explored. Especially, with the emergence of the combination of nanoflow capillary high-performance liquid chromatography (cHPLC) and Bio-MS, attention is again refocused on utilizing multi-dimensional liquid-phase based separation of proteins. Some remarkable applications of on-line analysis of intact proteins and on-column digested proteins, and the emergence of approaches such as multiple HPLC-electrospray ionization tandem MS and capillary array electrophoresis-matrix assisted laser desorption ionization MS, have stimulated thinking towards developing a automated multi-dimensional system (MuDSy) that integrates liquid phase based separation, digestion and identification of proteins in complex biological mixtures.  相似文献   

7.
8.
Serum analysis represents an extreme challenge due to the dynamic range of the proteins of interest, and the high structural complexity of the constituent proteins. In serum, the quantities of proteins and peptides of interest range from those considered "high abundance", present at 2-70% by mass of total protein, to those considered "low abundance", present at 10(-12) M or less. This range of analytical target molecules is outside the realm of available technologies for proteomic analysis. Therefore, in this study, we have developed a workflow toward addressing the complexity of these samples through the application of multidimensional separation techniques. The use of reversed-phase methods for the separation and fractionation of protein samples has been investigated, with the goal of developing an optimized serum separation for application to proteomic analysis. Samples of human serum were depleted of the six most abundant proteins, using an immunoaffinity LC method, then were separated under a variety of reversed-phase (RP) conditions using a macroporous silica C18 surface modified column material. To compare the qualities of the RP separations of this complex protein sample, absorbance chromatograms were compared, and fractions were collected for off-line SDS-PAGE and 2D-LC-MS/MS analysis. The column fractions were further investigated by determination of protein identities using either whole selected fractions, or gel bands excised from SDS-PAGE gels of the fractions. In either case samples underwent tryptic fragmentation and peptide analysis using MALDI-MS or LC-MS/MS. The preferred conditions for RP protein separation exhibited reproducibly high resolution and high protein recoveries (>98%, as determined by protein assay). Using the preferred conditions also permitted high column mass load, with up to 500 microg of protein well tolerated using a 4.6 mm ID x 50 mm column, or up to 1.5 mg on a 9.4 mm ID x 50 mm column. Elevated column temperature (80 degrees C) was observed to be a critical operational parameter, with poorer results observed at lower temperatures. The combination of sample simplification by immunoaffinity depletion combined with a robust and high recovery RP-HPLC fractionation yields samples permitting higher quality protein identifications by coupled LC-MS methods.  相似文献   

9.
Matrix-assisted laser desorption/ionisation (MALDI) mass spectrometry (MS) is a highly versatile and sensitive analytical technique, which is known for its soft ionisation of biomolecules such as peptides and proteins. Generally, MALDI MS analysis requires little sample preparation, and in some cases like MS profiling it can be automated through the use of robotic liquid-handling systems. For more than a decade now, MALDI MS has been extensively utilised in the search for biomarkers that could aid clinicians in diagnosis, prognosis, and treatment decision making. This review examines the various MALDI-based MS techniques like MS imaging, MS profiling and proteomics in-depth analysis where MALDI MS follows fractionation and separation methods such as gel electrophoresis, and how these have contributed to prostate cancer biomarker research. This article is part of a Special Issue entitled: Biomarkers: A Proteomic Challenge.  相似文献   

10.
Microdissecting the proteome   总被引:1,自引:0,他引:1  
von Eggeling F  Melle C  Ernst G 《Proteomics》2007,7(16):2729-2737
The complexity of the proteome is extremely high, because every organ or even a part of it can differ considerably in its protein composition. Performing proteomic studies therefore means to separate these functional different tissue areas before analysis. Otherwise all gained results will be depending on the question whether they are incorrect or at least dubious and do they reflect the different functions of tissues at all. The separation of functional tissue areas can be achieved by laser-based microdissection. In this review we will discuss the compatibly of microdissected formalin or cryofixed tissue with different proteomic techniques like 2-DE, MS and protein arrays.  相似文献   

11.
Proteome analysis requires a comprehensive approach including high-performance separation methods, mass spectrometric analysis, and bioinformatics. While recent advances in mass spectrometry (MS) have led to remarkable improvements in the ability to characterize complex mixtures of biomolecules in proteomics, a proper pre-MS separation step of proteins/peptides is still required. The need of high-performance separation and/or isolation/purification techniques of proteins is increasing, due to the importance of proteins expressed at extremely low levels in proteome samples. In this review, flow field-flow fractionation (F4) is introduced as a complementary pre-analytical separation method for protein separation/isolation, which can be effectively utilized for proteomic research. F4 is a set of elution-based techniques that are capable of separating macromolecules by differences in diffusion coefficient and, therefore, in hydrodynamic size. F4 provides protein separation without surface interaction of the analyte with packing or gel media. Separation is carried out in an open channel structure by a flow stream of a mobile phase of any composition, and it is solely based on the interaction of the analytes with a perpendicularly-applied, secondary flow of the fluid. Therefore, biological analytes such as proteins can be kept under a bio-friendly environment without losing their original structural configuration. Moreover, proteins fractionated on a size/shape basis can be readily collected for further characterization or proteomic analysis by MS using, for instance, either on-line or off-line methods based on electrospray ionization (ESI) or matrix-assisted laser desorption-ionization (MALDI). This review focuses on the advantages of F4 compared to most-assessed separation/isolation techniques for proteomics, and on selected applications based on size-dependent proteome separation. New method developments based on the hyphenation of F4 with on-line or off-line MS, and with other separation methods such as capillary isoelectric focusing (CIEF) are also described.  相似文献   

12.
We describe and review progress towards a global strategy that aims to extend the sensitivity, dynamic range, comprehensiveness, and throughput of proteomic measurements for microbial systems based upon the use of polypeptide accurate mass tags (AMTs) produced by global protein enzymatic digestions. The two-stage strategy exploits high accuracy mass measurements using Fourier transform ion cyclotron resonance mass spectrometry (FTICR) to validate polypeptide AMTs for a specific organism, from potential mass tags tentatively identified using tandem mass spectrometry (MS/MS), providing the basis for subsequent measurements without the need for routine MS/MS. A high-resolution capillary liquid chromatography separation combined with high sensitivity, and high-resolution accurate FTICR measurements is shown to be capable of characterizing polypeptide mixtures of more than 10(5) components, sufficient for broad protein identification using AMTs. Advantages of the approach include the high confidence of protein identification, its broad proteome coverage, and the capability for stable-isotope labeling methods for precise relative protein abundance measurements. The strategy has been initially evaluated using the microorganisms Saccharomyces cerevisiae and Deinococcus radiodurans. Additional developments, including the use of multiplexed-MS/MS capabilities and methods for dynamic range expansion of proteome measurements that promise to further extend the quality of proteomics measurements, are also described.  相似文献   

13.
High-field asymmetric waveform ion mobility spectrometry (FAIMS) is an atmospheric pressure ion mobility technique that separates gas-phase ions by their behavior in strong and weak electric fields. FAIMS is easily interfaced with electrospray ionization and has been implemented as an additional separation mode between liquid chromatography (LC) and mass spectrometry (MS) in proteomic studies. FAIMS separation is orthogonal to both LC and MS and is used as a means of on-line fractionation to improve the detection of peptides in complex samples. FAIMS improves dynamic range and concomitantly the detection limits of ions by filtering out chemical noise. FAIMS can also be used to remove interfering ion species and to select peptide charge states optimal for identification by tandem MS. Here, the authors review recent developments in LC-FAIMS-MS and its application to MS-based proteomics.  相似文献   

14.
Large-scale metabolic profiling is expected to develop into an integral part of functional genomics and systems biology. The metabolome of a cell or an organism is chemically highly complex. Therefore, comprehensive biochemical phenotyping requires a multitude of analytical techniques. Here, we describe a profiling approach that combines separation by capillary liquid chromatography with the high resolution, high sensitivity, and high mass accuracy of quadrupole time-of-flight mass spectrometry. About 2000 different mass signals can be detected in extracts of Arabidopsis roots and leaves. Many of these originate from Arabidopsis secondary metabolites. Detection based on retention times and exact masses is robust and reproducible. The dynamic range is sufficient for the quantification of metabolites. Assessment of the reproducibility of the analysis showed that biological variability exceeds technical variability. Tools were optimized or established for the automatic data deconvolution and data processing. Subtle differences between samples can be detected as tested with the chalcone synthase deficient tt4 mutant. The accuracy of time-of-flight mass analysis allows to calculate elemental compositions and to tentatively identify metabolites. In-source fragmentation and tandem mass spectrometry can be used to gain structural information. This approach has the potential to significantly contribute to establishing the metabolome of Arabidopsis and other model systems. The principles of separation and mass analysis of this technique, together with its sensitivity and resolving power, greatly expand the range of metabolic profiling.  相似文献   

15.
Next to the identification of proteins and the determination of their expression levels, the analysis of post-translational modifications (PTM) is becoming an increasingly important aspect in proteomics. Here, we review mass spectrometric (MS) techniques for the study of protein glycosylation at the glycopeptide level. Enrichment and separation techniques for glycoproteins and glycopeptides from complex (glyco-)protein mixtures and digests are summarized. Various tandem MS (MS/MS) techniques for the analysis of glycopeptides are described and compared with respect to the information they provide on peptide sequence, glycan attachment site and glycan structure. Approaches using electrospray ionization and matrix-assisted laser desorption/ionization (MALDI) of glycopeptides are presented and the following fragmentation techniques in glycopeptide analysis are compared: collision-induced fragmentation on different types of instruments, metastable fragmentation after MALDI ionization, infrared multi-photon dissociation, electron-capture dissociation and electron-transfer dissociation. This review discusses the potential and limitations of tandem mass spectrometry of glycopeptides as a tool in structural glycoproteomics.  相似文献   

16.
The current state of proteomics technologies has sufficiently advanced to allow in-depth quantitative analysis of the plasma proteome and development of a related knowledge base. Here we review approaches that have been applied to increase depth of analysis by mass spectrometry given the substantial complexity of plasma and the vast dynamic range of protein abundance. Fractionation strategies resulting in reduced complexity of individual fractions followed by mass spectrometry analysis of digests from individual fractions has allowed well in excess of 1000 proteins to be identified and quantified with high confidence that span more than seven logs of protein abundance. Such depth of analysis has contributed to elucidation of plasma proteome variation in health and of protein changes associated with disease states.  相似文献   

17.
Glycosaminoglycans (GAGs) are heterogeneous, negatively charged, macromolecules that are found in animal tissues. Based on the form of component sugar, GAGs have been categorized into four different families: heparin/heparan sulfate, chondroitin/dermatan sulfate, keratan sulfate, and hyaluronan. GAGs engage in biological pathway regulation through their interaction with protein ligands. Detailed structural information on GAG chains is required to further understanding of GAG–ligand interactions. However, polysaccharide sequencing has lagged behind protein and DNA sequencing due to the non-template-driven biosynthesis of glycans. In this review, we summarize recent progress in the analysis of GAG chains, specifically focusing on techniques related to mass spectroscopy (MS), including separation techniques coupled to MS, tandem MS, and bioinformatics software for MS spectrum interpretation. Progress in the use of other structural analysis tools, such as nuclear magnetic resonance (NMR) and hyphenated techniques, is included to provide a comprehensive perspective.  相似文献   

18.
Current non-gel techniques for analyzing proteomes rely heavily on mass spectrometric analysis of enzymatically digested protein mixtures. Prior to analysis, a highly complex peptide mixture is either separated on a multidimensional chromatographic system or it is first reduced in complexity by isolating sets of representative peptides. Recently, we developed a peptide isolation procedure based on diagonal electrophoresis and diagonal chromatography. We call it combined fractional diagonal chromatography (COFRADIC). In previous experiments, we used COFRADIC to identify more than 800 Escherichia coli proteins by tandem mass spectrometric (MS/MS) analysis of isolated methionine-containing peptides. Here, we describe a diagonal method to isolate N-terminal peptides. This reduces the complexity of the peptide sample, because each protein has one N terminus and is thus represented by only one peptide. In this new procedure, free amino groups in proteins are first blocked by acetylation and then digested with trypsin. After reverse-phase (RP) chromatographic fractionation of the generated peptide mixture, internal peptides are blocked using 2,4,6-trinitrobenzenesulfonic acid (TNBS); they display a strong hydrophobic shift and therefore segregate from the unaltered N-terminal peptides during a second identical separation step. N-terminal peptides can thereby be specifically collected for further liquid chromatography (LC)-MS/MS analysis. Omitting the acetylation step results in the isolation of non-lysine-containing N-terminal peptides from in vivo blocked proteins.  相似文献   

19.
MS protein identification and quantitation are key proteomic techniques in biological research. Besides identification of proteins, MS is used increasingly to characterize secondary protein modifications. This often requires trimming the analytical strategy to a specific type of modification. Direct analysis of protein modifications in proteomic samples is often hampered by the limited dynamic range of current analytical tools. Here we present a fast, sensitive, multiplexed precursor ion scanning mode--implemented on a quadrupole-TOF instrument--that allows the specific detection of any modified peptide or molecule that reveals itself by a specific fragment ion or pattern of fragment ions within a complex proteomic sample. The high mass accuracy of the TOF mass spectrometer is available for the marker ion specificity and the precursor ion mass determination. The method is compatible with chromatographic separation. Fragment ions and intact molecular ions are acquired quasi-simultaneously by continuously switching the collision energy between elevated and low levels. Using this technique many secondary modifications can be analyzed in parallel; however, the number of peptides carrying a specific modification that can be analyzed successfully is limited by the chromatographic resolution or, more generally, by the depth of the resolved time domain.  相似文献   

20.
Affinity purification coupled to mass spectrometry (AP-MS) is gaining widespread use for the identification of protein-protein interactions. It is unclear, however, whether typical AP sample complexity is limiting for the identification of all protein components using standard one-dimensional LC-MS/MS. Multidimensional sample separation is useful for reducing sample complexity prior to MS analysis and increases peptide and protein coverage of complex samples. Here, we monitored the effects of upstream protein or peptide separation techniques on typical mammalian AP-MS samples, generated by FLAG affinity purification of four baits with different biological functions and/or subcellular distribution. As a first separation step, we employed SDS-PAGE, strong cation exchange LC, or reversed-phase LC at basic pH. We also analyzed the benefits of using an instrument with a faster scan rate, the new TripleTOF 5600 mass spectrometer. While all multidimensional approaches yielded a clear increase in spectral counts, the increase in unique peptides and additional protein identification was modest and came at the cost of increased instrument and handling time. The use of a high duty-cycle instrument achieved similar benefits without these drawbacks. An increase in spectral counts is beneficial when data analysis methods relying on spectral counts, including Significance Analysis of INTeractome (SAINT), are used.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号