首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A computational model was developed to identify the sites of third body particle embedment in a total hip acetabular component surface that are most problematic in terms of roughening the overpassing regions of the femoral head counterface, leading in turn to most severely accelerated polyethylene wear. The analytical approach used was to calculate loci of acetabular sites that, during the gait cycle, overpass previously documented regions of kinetically most critical femoral head roughening. Instantaneous local contact stress and sliding distance were postulated as factors contributing to the severity of the femoral head scratching/roughening which would be expected, due to otherwise-similar particles embedded along each such acetabular overpass locus. The computational results showed that the location of debris embedment was a potent determinant of the amount of polyethylene wear acceleration expected. The data also showed that the supero-lateral aspect of the acetabular cup is consistently and by far the most problematic area for third body particle embedment.  相似文献   

2.
Numerous supporting structures assist in the retention of the femoral head within the acetabulum of the normal hip joint including the capsule, labrum, and ligament of the femoral head (LHF). During total hip arthroplasty (THA), the LHF is often disrupted or degenerative and is surgically removed. In addition, a portion of the remaining supporting structures is transected or resected to facilitate surgical exposure. The present study analyzes the effects of LHF absence and surgical dissection in THA patients. Twenty subjects (5 normal hip joints, 10 nonconstrained THA, and 5 constrained THA) were evaluated using fluoroscopy while performing active hip abduction. All THA subjects were considered clinically successful. Fluoroscopic videos of the normal hips were analyzed using digitization, while those with THA were assessed using a computerized interactive model-fitting technique. The distance between the femoral head and acetabulum was measured to determine if femoral head separation occurred. Error analysis revealed measurements to be accurate within 0.75mm. No separation was observed in normal hips or those subjects implanted with constrained THA, while all 10 (100%) with unconstrained THA demonstrated femoral head separation, averaging 3.3mm (range 1.9-5.2mm). This study has shown that separation of the prosthetic femoral head from the acetabular component can occur. The normal hip joint has surrounding capsuloligamentous structures and a ligament attaching the femoral head to the acetabulum. We hypothesize that these soft tissue supports create a passive, resistant force at the hip, preventing femoral head separation. The absence of these supporting structures after THA may allow increased hip joint forces, which may play a role in premature polyethylene wear or prosthetic loosening.  相似文献   

3.
桂西北喀斯特洼地土壤有机碳和速效磷的空间变异   总被引:8,自引:0,他引:8  
张伟  陈洪松  王克林  侯娅  张继光 《生态学报》2007,27(12):5168-5175
空间变异性的研究有助于认识土壤养分的空间分布特征与生态过程之间的关系。采用网格取样(20m×20m),利用地统计学方法分析了典型喀斯特洼地土壤有机碳(SOC)和速效磷(AP)的空间变异特征。结果表明SOC和AP的半变异函数分别用球状模型和指数模型拟合的效果较好。块金效应对SOC和AP总变异的贡献分别为37.9%和49.8%,说明SOC主要受结构性因素控制,而AP受结构性因素和随机因素双重控制。SOC的分布呈明显的带状各向异性特征,在洼地的长轴方向具有较大的变程和较小的基台值,其全向半变异函数的相关距离为135.5m,与洼地不同种植类型地块的覆盖尺度基本相当。AP的分布特征与SOC存在明显差异,具有较大的漂移趋势,其相关距离为413.4m;但在分离漂移趋势后,其相关距离为167.4m,反映了不同地块间的施肥差异对AP的影响较大。喀斯特洼地SOC的空间分布主要受地形和土地利用结构控制,而AP的分布的规律性不明显,可能与施肥等因素的随机性较强有关。  相似文献   

4.
Although morphological plasticity has been observed in a variety of taxa, few experimental studies have compared the relative proportion of morphological variability that is accounted for by environmentally induced plasticity, and how much is because of genetically based differences among populations. We compared the morphology of six rainbow trout (Oncorhynchus mykiss) populations from different ecotypic categories that were raised under flowing vs. standing-water conditions. Our data indicate that both environmental conditions and ecotypic differences account for a significant proportion of variation in morphology. Among ecotype effects, however, accounted for a much larger proportion of morphological variability than environmental conditions. Rainbow trout from stream populations had deeper caudal peduncles, and longer fins than lake populations, and rainbow trout from a piscivorous population had larger mouth and head lengths than all other ecotypes. Environmentally induced differences in morphology were primarily related to differences in mouth and head lengths, as well as fin length. Relative to morphometric differences from natural rainbow trout populations, most characteristics deviated in the same direction in our experimental populations. Our data indicate that morphological differences across rainbow trout populations have a genetic basis and may represent locally adaptive characteristics and highlight the role of ecology in promoting phenotypic divergence.  相似文献   

5.
A new head exposure system for double-blind provocation studies investigating possible effects of 2.45 GHz Wi-Fi exposure on human sleep was developed and dosimetrically analyzed. The exposure system includes six simultaneously radiating directional antennas arranged along a circle (radius 0.6 m) around the test subject's head, and enables a virtually uniform head exposure, i.e. without any preferred direction of incidence, during sleep. The system is fully computer-controlled and applies a real wireless local area network (WLAN) signal representing different transmission patterns as expected in real WLAN scenarios, i.e. phases of “beacon only” as well as phases of different data transmission rates. Sham and verum are applied in a double-blind crossover study design and all relevant exposure data, i.e. forward and reverse power at all six antenna inputs, are continuously recorded for quality control. For a total antenna input power (sum of all antennas) of 220 mW, typical specific absorption rate (SAR) in cortical brain regions is approximately 1–2 mW/kg (mass average SAR over respective brain region), which can be seen as a realistic worst-case exposure level in real WLAN scenarios. Taking into account variations of head positions during the experiments, the resulting exposure of different brain regions may deviate from the given average SAR levels up to 10 dB. Peak spatial 10 g average SAR in all brain and all head tissues is between 1.5–3.5 and 10.4–25 mW/kg, respectively. Bioelectromagnetics. © 2020 Bioelectromagnetics Society.  相似文献   

6.
Aseptic loosening from polyethylene wear debris is the leading cause of failure for metal-on-polyethylene total hip implants. Third-body debris ingress to the bearing space results in femoral head roughening and acceleration of polyethylene wear. How third-body particles manage to enter the bearing space between the closely conforming articulating surfaces of the joint is not well understood. We hypothesize that one such mechanism is from convective fluid transport during subluxation of the total hip joint. To test this hypothesis, a three-dimensional (3D) computational fluid dynamics (CFD) model was developed and validated, to quantify fluid ingress into the bearing space during a leg-cross subluxation event. The results indicated that extra-articular joint fluid could be drawn nearly to the pole of the cup with even very small separations of the femoral head (<0.60mm). Debris suspended near the equator of the cup at the site of maximum fluid velocity just before the subluxation began could be transported to within 11 degrees from the cup pole. Larger head diameters resulted in increased fluid velocity at all sites around the entrance to the gap compared to smaller head sizes, with fluid velocity being greatest along the anterosuperolateral cup edge, for all head sizes. Fluid pathlines indicated that suspended debris would reach similar angular positions in the bearing space regardless of head size. Increased inset of the femoral head into the acetabular cup resulted both in higher fluid velocity and in transport of third-body debris further into the bearing space.  相似文献   

7.
《动物分类学报》2017,(1):71-89
Despite plenty of data in insects shape variation,papers on environmental factors effect on such variation are scarce and in ground beetles are practically absent.The aim of this research was to:(i) model the effect of the region of habitation,urbanization and habitat vegetation into the shape variation in widespread carabid species;(ii) describe sexual shape dimorphism in studied species.Samples were pitfall trapped in different regions of its area in the spectrum of anthropogenic influence (cities,suburbs,natural biotopes).One thousand and one hundred sixty-eight specimens were analyzed for six morphometric traits and terminal points of those measurements were used as landmarks for Procrustes analysis.We used linear models to reveal which factor (region,urbanization or vegetation) and in what direction affected beetles shape.Results showed that males in C.granulatus had more convex elytra and head,and the more convex in apical-basal direction pronotum.In its area from the east to the west elytra flattened in medial-distal direction and pronotum flattened in apical-distal direction.In disturbed urban environment beetles pronotum became more convex in both sexes and males elytra became more convex too.In open habitats (meadows,lawns) beetles became more flattened.  相似文献   

8.
1. Using sampling rates of 8–64 Hz we found clear indications of extensive and high frequency fluctuations of underwater photosynthetically active radiation (PAR) just below the surface (0.016–1.1 m) in some New Zealand water bodies. High variability and flashing occurred down to at least 3 m depth.
2. PAR variability increased under the influence of bright sunshine if wind roughening of the surface took place. Concomitantly, the average PAR levels declined by about 10%. However, even when the surface was shaded, high variability of PAR persisted.
3. Under a calm surface, PAR irradiance followed a log normal distribution. This occurred independently of the presence of direct sunlight. However, when the surface was roughened by wind in sunshine, PAR immediately switched to a Gumbel (extreme value type EV1) distribution.
4. Neither wave action nor wave focusing of incident irradiance would explain the wide range of PAR close to the water surface, although both factors add to the PAR variability.
5. The data indicate that transmittance through the surface is highly variable at the temporal and spatial scales studied, and that the irregularity of the air–water interface is instrumental in bringing about the observed fluctuations of PAR just below the surface.  相似文献   

9.
1. Using sampling rates of 8–64 Hz we found clear indications of extensive and high frequency fluctuations of underwater photosynthetically active radiation (PAR) just below the surface (0.016–1.1 m) in some New Zealand water bodies. High variability and flashing occurred down to at least 3 m depth.
2. PAR variability increased under the influence of bright sunshine if wind roughening of the surface took place. Concomitantly, the average PAR levels declined by about 10%. However, even when the surface was shaded, high variability of PAR persisted.
3. Under a calm surface, PAR irradiance followed a log normal distribution. This occurred independently of the presence of direct sunlight. However, when the surface was roughened by wind in sunshine, PAR immediately switched to a Gumbel (extreme value type EV1) distribution.
4. Neither wave action nor wave focusing of incident irradiance would explain the wide range of PAR close to the water surface, although both factors add to the PAR variability.
5. The data indicate that transmittance through the surface is highly variable at the temporal and spatial scales studied, and that the irregularity of the air–water interface is instrumental in bringing about the observed fluctuations of PAR just below the surface.  相似文献   

10.
Identification of genes that control variation in adaptive characters is a prerequisite for understanding the processes that drive sexual and natural selection. Male coloration and female colour perception play important roles in mate choice in the guppy (Poecilia reticulata), a model organism for studies of natural and sexual selection. We examined a potential source for the known variation in colour perception, by analysing genomic and complementary DNA sequences of genes that code for visual pigment proteins. We find high sequence variability, both within and between populations, and expanded copy number for long-wave sensitive (LWS) opsin genes. Alleles with non-synonymous changes that suggest dissimilar spectral tuning properties occur in the same population and even in the same individual, and the high frequency of non-synonymous substitutions argues for diversifying selection acting on these proteins. Therefore, variability in tuning amino acids is partitioned within individuals and populations of the guppy, in contrast to variability for LWS at higher taxonomic levels in cichlids, a second model system for differentiation owing to sexual selection. Since opsin variability parallels the extreme male colour polymorphism within guppy populations, we suggest that mate choice has been a major factor driving the coevolution of opsins and male ornaments in this species.  相似文献   

11.
Controversies over the molecular clock hypothesis were reviewed. Since it is evident that the molecular clock does not hold in an exact sense, accounting for evolution of the rate of molecular evolution is a prerequisite when estimating divergence times with molecular sequences. Recently proposed statistical methods that account for this rate variation are overviewed and one of these procedures is applied to the mitochondrial protein sequences and to the nuclear gene sequences from many mammalian species in order to estimate the time scale of eutherian evolution. This Bayesian method not only takes account of the variation of molecular evolutionary rate among lineages and among genes, but it also incorporates fossil evidence via constraints on node times. With denser taxonomic sampling and a more realistic model of molecular evolution, this Bayesian approach is expected to increase the accuracy of divergence time estimates.  相似文献   

12.
Wear of ultrahigh molecular weight polyethylene remains a primary factor limiting the longevity of total knee replacements (TKRs). However, wear testing on a simulator machine is time consuming and expensive, making it impractical for iterative design purposes. The objectives of this paper were first, to evaluate whether a computational model using a wear factor consistent with the TKR material pair can predict accurate TKR damage measured in a simulator machine, and second, to investigate how choice of surface evolution method (fixed or variable step) and material model (linear or nonlinear) affect the prediction. An iterative computational damage model was constructed for a commercial knee implant in an AMTI simulator machine. The damage model combined a dynamic contact model with a surface evolution model to predict how wear plus creep progressively alter tibial insert geometry over multiple simulations. The computational framework was validated by predicting wear in a cylinder-on-plate system for which an analytical solution was derived. The implant damage model was evaluated for 5 million cycles of simulated gait using damage measurements made on the same implant in an AMTI machine. Using a pin-on-plate wear factor for the same material pair as the implant, the model predicted tibial insert wear volume to within 2% error and damage depths and areas to within 18% and 10% error, respectively. Choice of material model had little influence, while inclusion of surface evolution affected damage depth and area but not wear volume predictions. Surface evolution method was important only during the initial cycles, where variable step was needed to capture rapid geometry changes due to the creep. Overall, our results indicate that accurate TKR damage predictions can be made with a computational model using a constant wear factor obtained from pin-on-plate tests for the same material pair, and furthermore, that surface evolution method matters only during the initial "break in" period of the simulation.  相似文献   

13.
The investigation of natural variability of metric morphological characters in frog gastrulation revealed that in genetically and environmentally homogeneous samples of embryos their variability is of a higher order of magnitude than that known for quantitative metric characters in adult organisms. Matching the coefficients of variation of characters under consideration to the specific rates of their changes in normal development revealed a strong positive correlation between the rates of morphological change and the amount of morphological variance. The increase in the variance is mainly in characters concerned with shaping of moving embryonic areas and arises as a result of a positive feedback between the movement of a given area and recruitment of cells from surrounding areas into the movement. The account of natural variation suggests a new model of amphibian gastrulation whose essential feature is the intimate connection between the movement and shaping of the dorsal blastopore lip of the gastrula.  相似文献   

14.
Occlusal wear rate and wear plane in two Chalcolithic ( approximately 6500-5500 BP) samples from the southern Levant were compared, using paired first and second mandibular molars. Though food staples in both societies were derived from agro-pastoralism, they were located in distinct environmental regions: Wadi (W.) Makkukh in the Judean desert, and Peqi'in in the Upper Galilee. Accordingly, it was predicted that variation in wear should occur due to their location in distinct environments. Jaw size and tooth size were measured to estimate the possible impact of these variables on wear scores. Molar occlusal surfaces were divided into four quadrants, and wear scores were recorded for each quadrant. Principal axis analysis was then performed between total wear scores of paired, adjacent first and second molars to assess wear rates. Principal axis analysis was also used to analyze the change in occlusal wear plane in each sample by comparing between-buccal-cusps wear scores of the first molar with lingual wear scores of the second molar. The results indicate that the occlusal wear plane was similar in both samples but that wear tended to be more rapid in W. Makkukh. Since both samples were similar in jaw/tooth size, it is argued that the results reflect less refined food-processing methods as well as the unintentional ingestion of sand by individuals interred in the Judean desert.  相似文献   

15.
The capability to predict in-vivo wear of knee replacements is a valuable pre-clinical analysis tool for implant designers. Traditionally, time-consuming experimental tests provided the principal means of investigating wear. Today, computational models offer an alternative. However, the validity of these models has not been demonstrated across a range of designs and test conditions, and several different formulas are in contention for estimating wear rates, limiting confidence in the predictive power of these in-silico models.This study collates and retrospectively simulates a wide range of experimental wear tests using fast rigid-body computational models with extant wear prediction algorithms, to assess the performance of current in-silico wear prediction tools.The number of tests corroborated gives a broader, more general assessment of the performance of these wear-prediction tools, and provides better estimates of the wear ‘constants’ used in computational models. High-speed rigid-body modelling allows a range of alternative algorithms to be evaluated. Whilst most cross-shear (CS)-based models perform comparably, the ‘A/A+B’ wear model appears to offer the best predictive power amongst existing wear algorithms. However, the range and variability of experimental data leaves considerable uncertainty in the results. More experimental data with reduced variability and more detailed reporting of studies will be necessary to corroborate these models with greater confidence. With simulation times reduced to only a few minutes, these models are ideally suited to large-volume ‘design of experiment’ or probabilistic studies (which are essential if pre-clinical assessment tools are to begin addressing the degree of variation observed clinically and in explanted components).  相似文献   

16.
To isolate the primary variables influencing acetabular cup and interface stresses, we performed an evaluation of cup loading and cup support variables, using a Statistical Design of Experiments (SDOE) approach. We developed three-dimensional finite element (FEM) models of the pelvis and adjacent bone. Cup support variables included fixation mechanism (cemented or noncemented), amount of bone support, and presence of metal backing. Cup loading variables included head size and cup thickness, cup/head friction, and conformity between the cup and head. Interaction between and among variables was determined using SDOE techniques. Of the variables tested, conformity, head size, and backing emerged as significant influences on stresses. Since initially nonconforming surfaces would be expected to wear into conforming surfaces, conformity is not expected to be a clinically significant variable. This indicates that head size should be tightly toleranced during manufacturing, and that small changes in head size can have a disproportionate influence on the stress environment. In addition, attention should be paid to the use of nonmetal backed cups, in limiting cup/bone interface stresses. No combination of secondary variables could compensate for, or override the effect of, the primary variables. Based on the results using the SDOE approach, adaptive FEM models simulating the wear process may be able to limit their parameters to head size and cup backing.  相似文献   

17.
A new finite element model (FEM) based on an elasto-plastic behavior of ultra high molecular weight polyethylene (UHMWPE) was used to study the wear behavior of UHMWPE acetabular cup, which has a 32 mm diameter femoral head. The model imposed a plastic yield stress of 8 MPa on the UHMWPE so that any stresses beyond this would automatically be redistributed to its neighbor. The FEM model adopted a unique mesh design based on an open cube concept which eliminated the problems of singularities. Wear prediction combined the influences of contact stress, sliding distance and a surface wear coefficient. The new model predicted significantly higher volumetric wear rate (57 mm(3)/yr) well within the average reported clinical values. The model was also used to study the effect of friction and clearance between the acetabular cup and the femoral head. Increase in friction increased the volumetric wear rate but did not appear to affect the linear wear rate, which remained at 0.12 +/- 0.02 mm/yr. The predicted wear was sensitive to clearance. It was found that when the clearance was close to 0 and >0.5mm, severe wear occurred. The best clearance range was between 0.1 and 0.15 mm where the average linear wear rate was 0.1mm/yr and the volumetric wear was 55 mm(3)/yr. The present work indicates the importance of avoiding too tight or too loose a diametrical clearance.  相似文献   

18.
As one of the alternatives to traditional metal-on-polyethylene total hip replacements, metal-on-metal hip resurfacing prostheses demonstrating lower wear have been introduced for younger and more active patients during the past decade. However, in vitro hip simulator testing for the predicted increased lifetime of these surface replacements is time-consuming and costly. Computational wear modelling based on the Archard wear equation and finite element contact analysis was developed in this study for artificial hip joints and particularly applied to metal-on-metal resurfacing bearings under simulator testing conditions to address this issue. Wear factors associated with the Archard wear equation were experimentally determined and based on the short-term hip simulator wear results. The computational wear simulation was further extended to a long-term evaluation up to 50 million cycles assuming that the wear rate stays constant. The prediction from the computational model shows good agreement with the corresponding simulator study in terms of volumetric wear and the wear geometry. The simulation shows the progression of linear wear penetrations, and the complexity of contact stress distribution on the worn bearing surfaces. After 50 million cycles, the maximum linear wear was predicted to be approximately 6 and 8 microm for the cup and head, respectively, and no edge contact was found.  相似文献   

19.
A new definition of the experimental wear factor was established and reported as a function of cross-shear motion and contact pressure using a multi-directional pin-on-plate wear testing machine for conventional polyethylene in the present study. An independent computational wear model was developed by incorporating the cross-shear motion and contact pressure-dependent wear factor into the Archard's law, in additional to load and sliding distance. The computational prediction of wear volume was directly compared with a simulator testing of a polyethylene hip joint with a 28 mm diameter. The effect of increasing the femoral head size was subsequently considered and was shown to increase wear, as a result of increased sliding distance and reduced contact pressure.  相似文献   

20.
Dislocation is a severe complication after total hip replacement which may cause revision surgery in some cases. The use of constraint inserts that are coupled to the femoral head by a snapping mechanism provides an opportunity for treatment of recurrent dislocations. This study was aimed to investigate the assembling and retention forces of a specific constraint liner. Using a universal testing machine the assembling forces were determined for head sizes of 28 and 32 mm and the clinically mostly used as well as the maximum cup size. Subsequently, under variation of load direction and pull-out velocity the retention forces were investigated. For primary assembly of the head the required compressive forces were in a range from 197 N and 283 N depending on head and cup size (each size n = 3). Repeated assembly led to a decrease of these forces up to 29%. The retention forces always were slightly below the assembling forces, i. e. forces to remove the heads from the inserts were between 183 N and 230 N (each size n = 3). Repeated disconnection caused a decrease of the retention forces up to 16%. An increase of load velocity as well as an oblique load direction resulted in an enhancement of the retention forces. For all investigated implant sizes the retention force for the femoral head was approximately ten-times less than the interface strength between the insert and the metal-back. In case of correct implant handling the risk of disconnection between the tested constraint insert and the corresponding metal-back has not to be considered in clinical practice.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号