首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A technique is described which allows neurons to be voltage clamped with a single microelectrode, and the advantages of this circuit with respect to conventional bridge techniques are discussed. In this circuit, the single micro electrode is rapidly switched from a current passing to a recording mode. The circuitry consists of: (1) an electronic switch; (2) a high impedance, ultralow input capacity amplifier; (3) a sample-and-hold module; (4) conventional voltage clamping circuitry. The closed electronic switch allows current to flow through the electrode. The switch then opens, and the electrode is in a recording mode. The low input capacity of the preamplifier allows the artifact from the current pulse to rapidly abate, after which time the circuit samples the membrane potential. This cycle is repeated at rates up to 10 kHz. The voltage clamping amplifier senses the output of the sample-and-hold module and adjusts the current pulse amplitude to maintain the desired membrane potential. The system was evaluated in Aplysia neurons by inserting two microelectrodes into a cell. One electrode was used to clamp the cell and the other to independently monitor membrane potential at a remote location in the soma.  相似文献   

2.
Voltage clamping with a single microelectrode.   总被引:6,自引:0,他引:6  
A technique is described which allows neurons to be voltage clamped with a single microelectrode, and the advantages of this circuit with respect to conventional bridge techniques are discussed. In this circuit, the single microelectrode is rapidly switched from a current passing to a recording mode. The circuitry consists of: (1) an electronic switch; (2) a high impedance, ultralow input capacity amplifier; (3) a sample-and-hold module; (4) conventional voltage clamping circuitry. The closed electronic switch allows current to flow through the electrode. The switch then opens, and the electrode is in a recording mode. The low input capacity of the preamplifier allows the artifact from the current pulse to rapidly abate, after which time the circuit samples the membrane potential. This cycle is repeated at rates up to 10 kHz. The voltage clamping amplifier senses the output of the sample-and-hold module and adjusts the current pulse amplitude to maintain the desired membrane potential. The system was evaluated in Aplysia neurons by inserting two microelectrodes into a cell. One electrode was used to clamp the cell and the other to independently monitor membrane potential at a remote location in the soma.  相似文献   

3.
4.
This report concerns the inference of geometric and mechanical airway characteristics based on information derived from a single transient planar wave recorded at the airway opening. We describe a new method to simultaneously measure upper airway area and respiratory input impedance by performing dual analysis of a single pressure wave. The algorithms required to reconstruct airway dimensions and mechanical characteristics were developed, implemented, and tested with reference to known physical models. Our method appears suitable to estimate, even under severe intensive care unit conditions, the respiratory system frequency response (above 10 Hz) in intubated patients and the patency of the endotracheal tube used to connect the patients to the ventilator.  相似文献   

5.
Purinergic signalling departs from traditional paradigms of neurotransmission in the variety of release mechanisms and routes of production of extracellular ATP and adenosine. Direct real-time measurements of these purinergic agents have been of great value in understanding the functional roles of this signalling system in a number of diverse contexts. Here, we review the methods for measuring purine release, introduce the concept of microelectrode biosensors for ATP and adenosine and explain how these have been used to provide new mechanistic insight in respiratory chemoreception, synaptic physiology, eye development and purine salvage. We finish by considering the association of purine release with pathological conditions and examine the possibilities that biosensors for purines may one day be a standard part of the clinical diagnostic tool chest.  相似文献   

6.

Purinergic signalling departs from traditional paradigms of neurotransmission in the variety of release mechanisms and routes of production of extracellular ATP and adenosine. Direct real-time measurements of these purinergic agents have been of great value in understanding the functional roles of this signalling system in a number of diverse contexts. Here, we review the methods for measuring purine release, introduce the concept of microelectrode biosensors for ATP and adenosine and explain how these have been used to provide new mechanistic insight in respiratory chemoreception, synaptic physiology, eye development and purine salvage. We finish by considering the association of purine release with pathological conditions and examine the possibilities that biosensors for purines may one day be a standard part of the clinical diagnostic tool chest.

  相似文献   

7.
We have built a flow system in which we can analyze and sort individual viable cells on the basis of their cytoplasmic microviscosity. The average cytoplasmic microviscosity (or cytoplasmic structuredness) of a cell can be quantitated by exciting fluorescein molecules in the cytoplasm of the cell with a polarized light source and measuring the extent of depolarization of the fluorescent signal. Changes in the state of a cell (e.g., the reception of a signal inducing the cell to differentiate) often appear to be associated with changes in cytoplasmic microviscosity, these changes being detectable within hours of the inducing signal. An example of one such change is presented.  相似文献   

8.
9.
Mice are used with increasing frequency as models of human cardiovascular diseases, but significant gaps exist in our knowledge of vascular function in the aging mouse. We determined aortic input impedance spectra, pulse wave velocity, and augmentation index in adult (8-mo-old) and old (29-mo-old) mice to determine whether arterial stiffening occurred with age in mice as it does in humans. Pressure and blood velocity signals measured simultaneously from the same location in the ascending aorta were used to determine input impedance spectra (0-10 harmonics). The first minimum of the impedance modulus occurred at the second harmonic in adult mice but shifted to the fourth harmonic in old mice. Characteristic impedance (average of 2nd-10th harmonic) was 57% higher in old mice: 471 +/- 62 vs. 299 +/- 10 (SE) dyn.s.cm-3 (P < 0.05). Pulse pressure and augmentation index, determined from the aortic pressure signals, were also higher in old mice: 42 +/- 2.2 vs. 29 +/- 4.9 mmHg (P < 0.05) and 37 +/- 5 vs. 14 +/- 2% (P < 0.005). Aortic pulse wave velocity measured from the timing of upstrokes of the Doppler velocity signals was 45% higher in old mice: 416 +/- 22 vs. 286 +/- 14 cm/s (n = 3, P < 0.01). These results reproduce age-related findings reported in humans and confirm that mice may be used as models of age-related vascular stiffening.  相似文献   

10.
11.
Particle resistivity is explicitly included in the equations relating volume to voltage pulse, in electronic cell sizing or resistive pulse spectroscopy (RPS). It has long been known that in high electric fields cell resistivity decreases as the membrane undergoes dielectric breakdown. At sufficiently high electric field strengths, well past dielectric breakdown, the red cell membrane becomes electrically transparent, or nearly so, and apparent cell size becomes essentially a function of the cytoplasmic resistivity. Electronic cell sizing is traditionally carried out at low electric field strengths, and corrections made for the influence of cell shape by use of the Laplace equation. We find the Laplace solution to be still applicable at very high electric field strengths for purposes of calculating specific cytoplasmic resistivity from RPS measurements. Our value for discocytes, 220 omega X cm, is in good agreement with published results obtained by other researchers using other techniques. We have also applied these same procedures to determine the time course of voltage-dependent resistivity changes in ghosts and intact spherocytes, during the first 5 min after suspension in hypotonic medium. We believe these to be the first explicit calculations of particle specific resistivity from post-dielectric-breakdown apparent size, using traditional electronic sizing techniques.  相似文献   

12.
Flow and pressure measurements were performed in the ascending aortas of six pediatric patients ranging in age from 1 to 4 yr and in weight from 7.2 to 16.4 kg. From these measurements, input impedance was calculated. It was found that total vascular resistance decreased with increasing patient weight and was approximately one to three times higher than those of adults. Conductance per unit weight was relatively constant but was approximately three times higher than for adults. Strong inertial character was observed in the impedance of four of the six patients. Among a three-element and two four-element lumped-parameter models, the model with characteristic aortic resistor (R(c)) and inertance in series followed by parallel peripheral resistor (R(p)) and compliance fitted the data best. R(p) decreased with increasing patient weight and was one to three times higher than in adults, and R(c) decreased with increasing patient weight and was 2 to 15 times higher. The R(p)-to-R(c) ratio differed significantly between infants and children vs. adults. The results suggested that R(p) developed more rapidly with patient weight than did R(c). Compliance values increased with increasing patient weight and were 3 to 16 times lower than adult values.  相似文献   

13.
14.
For a feasible and cost-effective impedance measurement of cellular alterations in real-time, we combined commercially available microelectrode arrays (MEAs), consisting of 60 microelectrodes, with a conventional impedance analyzer. For proof of principle, a breast carcinoma cell line (MCF-7) was cultured on MEAs, and cellular alterations were measured by impedance spectroscopy at a frequency ranging from 10 Hz to 1 MHz. Cells were stimulated with phorbol 12-myristate 13-acetate (PMA) at different concentrations to activate protein kinase C (PKC)-mediated extra- and intracellular changes. By addition of 0.03 microM PMA, an increase of the relative impedance (Z(rel)) was observed after 10 min with a maximum at 1 kHz. Moreover a gradual elevation of the impedance was measured 60 min after stimulation with PMA. If 0.3 microM PMA was applied, the maximal amplitude of the relative impedance after 60 min shifted from 1 kHz (0.03 microM PMA) to 150 Hz. Subsequently, the impedance was further increased up to 90 min after PMA application, after which the impedance reduced after 240 min. Since we could use MEAs for at least 10 times without affecting the sensitivity, our study revealed that commercially available MEAs comprising nanocolumnar titanium nitrite electrodes are suitable microstructures for a highly reproducible and cost-effective multisite measurement of intracellular processes by impedance spectroscopy.  相似文献   

15.
16.
17.
It is well recognized that label-free biosensors are the only class of sensors that can rapidly detect antigens in real-time and provide remote environmental monitoring and point-of-care diagnosis that is low-cost, specific, and sensitive. Electrical impedance spectroscopy (EIS) based label-free biosensors have been used to detect a wide variety of antigens including bacteria, viruses, DNA, and proteins due to the simplicity of their detection technique. However, their commercial development has been hindered due to difficulty in interpreting the change in impedance upon antigen binding and poor signal reproducibility as a result of surface fouling and non-specific binding. In this study, we develop a circuit model to adequately describe the physical changes at bio functionalized surface and provide an understanding of the detection mechanism based on electron exchange between electrolyte and surface through pores surrounding antibody-antigen. The model was successfully applied to extract quantitative information about the bio surface at different stages of surface functionalization. Further, we demonstrate boron-doped ultrananocrystalline diamond (UNCD) microelectrode array (3 × 3 format, 200 μm diameter) improves signal reproducibility significantly and increases sensitivity by four orders of magnitude. This study marks the first demonstration of UNCD array based biosensor that can reliably detect a model Escherichia coli K12 bacterium using EIS, positioning this technology for rapid adoption in point-of-use applications.  相似文献   

18.
A renewable, site-selective immobilization platform of microelectrode array (MEA) for multiplexed immunoassays has been initially developed using pencil graphite particles coated with gold layers as microelectrodes. The graphite particles available on the common pencil were utilized for directing the electro-deposition of gold layers with uniform microstructures which displayed a well-defined sigmoidal voltammetric response. In the concept-of-proof experiments, the resulting MEA platform was modified with functionalized monolayer, on which anti-human IgG antibodies could be stably immobilized in a site-selective way through binding chemistry to selectively capture human IgG antigens from the sample media. The subsequent introduction of anti-human IgG antibodies conjugated with 15 nm electro-active gold nanoparticles to recognize the captured IgG proteins resulted in a significant decrease in the interfacial electron-transfer resistance. High sensitive electrochemical quantification by gold nanoparticle-amplified impedance responses could thus be achieved. Experimental results show that the developed MEA sensor can allow for the detection of human IgG with wide linear range (0.05–100 ng ml−1) and sensitivity over 103 larger than that of the conventional, bulk gold electrode. The rapid regeneration of the used MEA platform can additionally be realized by a simple electrochemical treatment. The high selectivity of four individually addressable MEA platforms for multiple antigens in a single sample has been further demonstrated in the multiplexed immunoassay experiments. Such a site-selective immobilization strategy of MEA platform may open a new door towards the development of various simple, sensitive, cost-effective, and reusable biological sensors and biochips.  相似文献   

19.
The cytoplasmic resistivities and membrane breakdown potentials of normal (AA), sickle-cell-trait (AS), as sickle (SS) red blood cells have been measured by the biophysical methodology of resistive pulse spectroscopy over a range of osmolalities. At isotonicity, the average membrane breakdown potentials are virtually identical for the three types of cells occurring at about 1150 V/cm. Average isotonic cytoplasmic resistivities are somewhat higher for the SS cells (166.7 +/- 7.49 ohm-cm) compared to the AA (147.6 +/- 1.98 ohm-cm) or AS cells (148.7 +/- 1.79 ohm-cm). As medium osmolality is varied, the differences in resistive properties become enlarged, especially at very low and very high osmolalities. At high osmolalities, both types of sickle cells show a large increase in internal resistivity compared to the normals; at low osmolality, the SS samples exhibit a distinctly different membrane breakdown characteristic, decreasing in this parameter, whereas the other two groups increase. Of the 15 SS samples tested, three displayed much higher cytoplasmic resistivities at isotonicity: 218.2 +/- 5.25 ohm-cm, compared to an average of 153.5 +/- 3.46 ohm-cm for the other 12. The relationship between these high resistivities and the subfraction of irreversibly sickled cells in the sample is discussed.  相似文献   

20.
The cytoplasmic resistivities and membrane breakdown potentials of normal (AA), sickle-cell-trait (AS), and sickle (SS) red blood cells have been measured by the biophysical methodology of resistive pulse spectroscopy over a range of osmolalities. At isotonicity, the average membrane breakdown potentials are virtually identical for the three types of cells occurring at about 1150 V/cm. Average isotonic cytoplasmic resistivities are somewhat higher for the SS cells (166.7±7.49 ohm-cm) compared to the AA (147.6±1.98 ohm-cm) or AS cells (148.7±1.79 ohm-cm). As medium osmolality is varied, the differences in resistive properties become enlarged, especially at very low and very high osmolalities. At high osmolalities, both types of sickle cells show a large increase in internal resistivity compared to the normals; at low osmolality, the SS samples exhibit a distinctly different membrane breakdown characteristic, decreasing in this parameter, whereas the other two groups increase. Of the 15 SS samples tested, three displayed much higher cytoplasmic resistivities at isotonicity: 218.2±5.25 ohm-cm, compared to an average of 153.5±3.46 ohm-cm for the other 12. The relationship between these high resistivities and the subfraction of irreversibly sickled cells in the sample is discussed.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号