首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
2.
RNA amplification strategies for cDNA microarray experiments   总被引:5,自引:0,他引:5  
  相似文献   

3.
4.
DNA microarray technology has been widely used to simultaneously determine the expression levels of thousands of genes. A variety of approaches have been used, both in the implementation of this technology and in the analysis of the large amount of expression data. However, several practical issues still have not been resolved in a satisfactory manner, and among the most critical is the lack of agreement in the results obtained in different array platforms. In this study, we present a comparison of several microarray platforms [Affymetrix oligonucleotide arrays, custom complementary DNA (cDNA) arrays, and custom oligo arrays printed with oligonucleotides from three different sources] as well as analysis of various methods used for microarray target preparation and the reference design. The results indicate that the pairwise correlations of expression levels between platforms are relative low overall but that the log ratios of the highly expressed genes are strongly correlated, especially between Affymetrix and cDNA arrays. The microarray measurements were compared with quantitative real-time-polymerase chain reaction (QRT-PCR) results for 23 genes, and the varying degrees of agreement for each platform were characterized. We have also developed and tested a double amplification method which allows the use of smaller amounts of starting material. The added round of amplification produced reproducible results as compared to the arrays hybridized with single round amplified targets. Finally, the reliability of using a universal RNA reference for two-channel microarrays was tested and the results suggest that comparisons of multiple experimental conditions using the same control can be accurate.  相似文献   

5.
Optimized T7 amplification system for microarray analysis.   总被引:8,自引:0,他引:8  
  相似文献   

6.
7.
8.
9.
DNA microarray technology has been increasingly applied for studies of clinical samples. Frequently, RNA probes from clinical samples are available in limited amounts. We describe a reliable amplification method for bacterial RNA. We verified this method on mycobacterial RNA applying mycobacterial genome-directed primers (mtGDPs). Glass slide-based oligoarrays were employed to assess the quality of the amplification method. We observed a relatively small bias in amplified RNA pool when compared to the unamplified one. Up to 1000-fold linear RNA amplification in a single amplification round was obtained. To our knowledge, this study describes the first amplification method for mycobacterial RNA.  相似文献   

10.
11.
Lau WK  Chiu SK  Ma JT  Tzeng CM 《BioTechniques》2002,33(3):564, 566-564, 570
The application of microarray analysis to gene expression from limited tissue samples has not been very successful because of the poor signal qualityfrom the genes expressed at low levels. Here we discussed the use of catalyzed reporter deposition (CARD) technology to amplify signals from limited RNA samples on nylon membrane cDNA microarray. When the input RNA level was greater than 10 microg, the genes expressed at high levels did not amplify in proportion to those expressed at low levels. Compared to conventional colorimetric detection, the CARD method requires less than 10% of the total RNA used for amplification of signal displayed onto a nylon membrane cDNA microarray. Total RNA (5-10 microg), as one can extract from a limited amount of specimen, was determined to produce a linear correlation between the colorimetric detection and CARD methods. Beyond this range, it can cause a nonlinear amplification of highly expressed and low-abundance genes. These results suggest that when amplification is needed for any applications using the CARD method, including DNA microarray experiments, precaution has to be taken in the amount of RNA used to avoid skew amplification and thus misleading conclusions.  相似文献   

12.
DNA微阵列能在一次实验中检测成千上万个基因的表达情况, 有助于阐明疾病发生的分子机制及发现新的诊治靶标.但常规方法需要大量RNA, 因而基于T7 RNA线性扩增技术逐渐成为微阵列表达谱实验中最常用的探针制备方法.本方法将实验步骤进一步改进,增加额外的一轮体外转录,并结合Klenow酶标记技术来制备cDNA靶标和寡核苷酸芯片杂交.从纳克量级的总RNA起始,本方法和常规的RNA单轮线性扩增法相比,仍然准确地保留了约70%的基因表达信息.同一RNA样本的自身比较实验及重复实验结果也显示,该方法具有较高的可靠性和重复性.RNA双轮体外扩增法需要的起始RNA相对于常规的单轮扩增法减少了很多(10 ng甚至更少),因而非常适合分析那些只能提供微量RNA的样本.  相似文献   

13.
Analysis of cell-specific gene expression patterns using microarrays can reveal genes that are differentially expressed in diseased and normal tissue, as well as identify genes associated with specialized cellular functions. However, the cellular heterogeneity of the tissues precludes the resolution of expression profiles of specific cell types. While laser capture microdissection (LCM) can be used to obtain purified cell populations, the limited quantity of RNA isolated makes it necessary to perform an RNA amplification step prior to microarray analysis. The linearity and reproducibility of two RNA amplification protocols--the Baugh protocol (Baugh et al., 2001, Nucleic Acids Res 29:E29) and an in-house protocol have been assessed by conducting microarray analyses. Cy3-labeled total RNA from the colorectal cell line Colo-205 was compared to Cy5-labeled Colo-205 amplified RNA (aRNA) generated with each of the two protocols, using a human 10K cDNA array. The correlation of the gene intensities between amplified and total RNA measured in the two channels of each microarray was 0.72 and 0.61 for the Baugh protocol and the in-house protocol, respectively. The two protocols were further evaluated using aRNA obtained from normal colonic crypt cross-sections isolated via LCM. In both cases a microarray profile representative of colonic mucosa was obtained; statistically, the Baugh protocol was superior. Furthermore, a substantial overlap between highly expressed genes in the Colo-205 cells and colonic crypts underscores the reliability of the microarray analysis of LCM-derived material. Taken together, these results demonstrate that LCM-derived tissue from histological specimens can generate abundant amounts of high-quality aRNA for subsequent microarray analysis.  相似文献   

14.
Puskás LG  Zvara A  Hackler L  Micsik T  van Hummelen P 《BioTechniques》2002,33(4):898-900, 902, 904
In DNA microarray technology, repeatability and reliability are very important to compare multiple RNA samplesfrom different experiments. The application of common or universal RNA as a standard control equalizes the differences in hybridization parameters and array variations. For this purpose, high-quality reference RNA is necessary in bulk amounts. A novel approach was developed to get milligrams of sense or antisense RNA, starting from micrograms of pooled total RNA from different cell lines, tissues, or organisms. This method is inexpensive and allows further labeling procedures using poly(dT) or random oligomers as primers. In addition, amplified, sense reference RNA is suitable for standard labeling protocols, while the antisense reference RNA can be used with antisense RNA from the linear sample amplification method. Here we produced universal RNA for human, rat, and alfalfa and demonstrated the quality using specific cDNA microarrays.  相似文献   

15.
16.
17.
18.

Background  

A limiting factor of cDNA microarray technology is the need for a substantial amount of RNA per labeling reaction. Thus, 20–200 micro-grams total RNA or 0.5–2 micro-grams poly (A) RNA is typically required for monitoring gene expression. In addition, gene expression profiles from large, heterogeneous cell populations provide complex patterns from which biological data for the target cells may be difficult to extract. In this study, we chose to investigate a widely used mRNA amplification protocol that allows gene expression studies to be performed on samples with limited starting material. We present a quantitative study of the variation and noise present in our data set obtained from experiments with either amplified or non-amplified material.  相似文献   

19.
20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号