首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) was used to investigate whole and freeze-thawed Cryptosporidium parvum oocysts. Whole oocysts revealed some mass spectral features. Reproducible patterns of spectral markers and increased sensitivity were obtained after the oocysts were lysed with a freeze-thaw procedure. Spectral-marker patterns for C. parvum were distinguishable from those obtained for Cryptosporidium muris. One spectral marker appears specific for the genus, while others appear specific at the species level. Three different C. parvum lots were investigated, and similar spectral markers were observed in each. Disinfection of the oocysts reduced and/or eliminated the patterns of spectral markers.  相似文献   

2.
The identification of proteins separated on two-dimensional gels is most commonly performed by trypsin digestion and subsequent matrix-assisted laser desorption ionization (MALDI) with time-of-flight (TOF). Recently, atmospheric pressure (AP) MALDI coupled to an ion trap (IT) has emerged as a convenient method to obtain tandem mass spectra (MS/MS) from samples on MALDI target plates. In the present work, we investigated the feasibility of using the two methodologies in line as a standard method for protein identification. In this setup, the high mass accuracy MALDI-TOF spectra are used to calibrate the peptide precursor masses in the lower mass accuracy AP-MALDI-IT MS/MS spectra. Several software tools were developed to automate the analysis process. Two sets of MALDI samples, consisting of 142 and 421 gel spots, respectively, were analyzed in a highly automated manner. In the first set, the protein identification rate increased from 61% for MALDI-TOF only to 85% for MALDI-TOF combined with AP-MALDI-IT. In the second data set the increase in protein identification rate was from 44% to 58%. AP-MALDI-IT MS/MS spectra were in general less effective than the MALDI-TOF spectra for protein identification, but the combination of the two methods clearly enhanced the confidence in protein identification.  相似文献   

3.
Although peptide mass fingerprinting is currently the method of choice to identify proteins, the number of proteins available in databases is increasing constantly, and hence, the advantage of having sequence data on a selected peptide, in order to increase the effectiveness of database searching, is more crucial. Until recently, the ability to identify proteins based on the peptide sequence was essentially limited to the use of electrospray ionization tandem mass spectrometry (MS) methods. The recent development of new instruments with matrix-assisted laser desorption/ionization (MALDI) sources and true tandem mass spectrometry (MS/MS) capabilities creates the capacity to obtain high quality tandem mass spectra of peptides. In this work, using the new high resolution tandem time of flight MALDI-(TOF/TOF) mass spectrometer from Applied Biosystems, examples of successful identification and characterization of bovine heart proteins (SWISS-PROT entries: P02192, Q9XSC6, P13620) separated by two-dimensional electrophoresis and blotted onto polyvinylidene difluoride membrane are described. Tryptic protein digests were analyzed by MALDI-TOF to identify peptide masses afterward used for MS/MS. Subsequent high energy MALDI-TOF/TOF collision-induced dissociation spectra were recorded on selected ions. All data, both MS and MS/MS, were recorded on the same instrument. Tandem mass spectra were submitted to database searching using MS-Tag or were manually de novo sequenced. An interesting modification of a tryptophan residue, a "double oxidation", came to light during these analyses.  相似文献   

4.
Direct matrix-assisted laser desorption/ionization-time of flight mass spectrometry (MALDI-TOF MS) analysis of human serum yielded ion signals from only a fraction of the total number of peptides and proteins expected to be in the sample. We increased the number of peptide and protein ion signals observed in the MALDI-TOF mass spectra analysis of human serum by using a prefractionation protocol based on liquid phase isoelectric focusing electrophoresis. This pre-fractionation technique facilitated the MALDI-TOF MS detection of as many as 262 different peptide and protein ion signals from human serum. The results obtained from three replicate fractionation experiments on the same serum sample indicated that 148 different peptide and protein ion signals were reproducibly detected using our isoelectric focusing and MALDI-TOF MS protocol.  相似文献   

5.
Matrix-assisted laser desorption ionization–time of flight mass spectrometry (MALDI-TOF MS) was used to investigate whole and freeze-thawed Cryptosporidium parvum oocysts. Whole oocysts revealed some mass spectral features. Reproducible patterns of spectral markers and increased sensitivity were obtained after the oocysts were lysed with a freeze-thaw procedure. Spectral-marker patterns for C. parvum were distinguishable from those obtained for Cryptosporidium muris. One spectral marker appears specific for the genus, while others appear specific at the species level. Three different C. parvum lots were investigated, and similar spectral markers were observed in each. Disinfection of the oocysts reduced and/or eliminated the patterns of spectral markers.  相似文献   

6.
in mass spectrometry have enabled the investigation of various biological systems by directly analyzing diverse sets of biomolecules (i.e., proteins, lipids, and carbohydrates), thus making a significant impact on the life sciences field. Over the past decade, matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) has been widely utilized as a rapid and reliable method for the identification of microorganisms. MALDI-TOF MS has come into widespread use despite its relatively low resolving power (full width at half maximum, FWHM: < 5,000) and its incompatibility with tandem MS analysis, features with which other high-resolution mass spectrometers are equipped. Microbial identification is achieved by searching databases containing mass spectra of peptides and proteins extracted from microorganisms of interest, using scoring algorithms to match analyzed spectra with reference spectra. In this paper, we give a brief overview of the diverse applications of rapid and robust MALDI-TOF MS-based techniques for microbial identification in a variety of fields, such as clinical diagnosis and environmental and food monitoring. We also describe the fundamental principles of MALDI-TOF MS. The general specifications of the two major MS-based microbial identification systems available in the global market (BioTyper® and VITEK® MS Plus) and the distribution of these instruments in Republic of Korea are also discussed. The current review provides an understanding of this emerging microbial identification and classification technology and will help bacteriologists and cell biologists take advantage of this powerful technique.  相似文献   

7.
【目的】基质辅助激光解吸电离飞行时间质谱(MALDI-TOF MS)法基于微生物的特征蛋白指纹图谱鉴定菌种,本研究利用基因组学和MALDI-TOFMS技术鉴定放线菌纲细菌的核糖体蛋白质标志物。【方法】从MALDI-TOF MS图谱数据库选取放线菌纲代表菌种,在基因组数据库检索目标菌种,获取目标菌株或其参比菌株的核糖体蛋白质序列,计算获得分子质量理论值,用于注释目标菌株MALDI-TOFMS指纹图谱中的核糖体蛋白质信号。【结果】从8目,24科,53属,114种,142株放线菌的MALDI-TOFMS图谱中总共注释出31种核糖体蛋白质。各菌株的指纹图谱中核糖体蛋白质信号数量差异显著。各种核糖体蛋白质信号的注释次数差异显著。总共15种核糖体蛋白质在超过半数图谱中得到注释,注释次数最高的是核糖体大亚基蛋白质L36。【结论】本研究找到了放线菌纲细菌MALDI-TOF MS图谱中常见的15种核糖体蛋白质信号,可为通过识别核糖体蛋白质的质谱特征峰鉴定放线菌的方法建立提供依据。  相似文献   

8.
Matrix-assisted laser desorption and ionization time-of-flight mass spectrometry (MALDI-TOF MS) is increasingly applied to lipids. However, positional acyl chain analysis of lipids by MALDI was so far scarcely described. In this paper, the fragmentation behavior of phosphatidylethanolamine (PE) is investigated by using post-source decay (PSD) MS. In dependence on the investigated adduct, significant differences could be obtained. It will be shown that in particular the negative ion spectra enable the determination of the individual acyl chains as well as their positions (sn-1 or sn-2). Therefore, MALDI-TOF PSD spectra are a real alternative to more sophisticated MS/MS methods.  相似文献   

9.
Matrix-assisted laser desorption and ionization time-of-flight mass spectrometry (MALDI-TOF MS) is increasingly applied to lipids. However, positional acyl chain analysis of lipids by MALDI was so far scarcely described.In this paper, the fragmentation behavior of phosphatidylethanolamine (PE) is investigated by using post-source decay (PSD) MS. In dependence on the investigated adduct, significant differences could be obtained. It will be shown that in particular the negative ion spectra enable the determination of the individual acyl chains as well as their positions (sn-1 or sn-2). Therefore, MALDI-TOF PSD spectra are a real alternative to more sophisticated MS/MS methods.  相似文献   

10.
Enzymatic oxidation of two phenolic compounds [syringic acid (3,5-dimethoxy-4-hydroxybenzoic acid) and 2,6-dimethylphenol] was studied. The products of laccase- and laccase-mediator-catalyzed oxidation reactions were monitored by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) and further analyzed by electrospray ionization Fourier transform ion cyclotron resonance (ESI-FTICR) MS with collision-induced dissociation (CID) experiments. For the oligomers of syringic acid, some variability was observed in MALDI-TOF analysis. However, the origin of this variability could not be resolved on the basis of MALDI-TOF spectra due to the poor resolution of the instrument in use. The strength of ESI-FTICR MS was the high-resolution data provided from oligomers of syringic acid. The CID experiments were extremely useful for structural studies of oligomers and verified that the variability of the products was due to the end groups; the phenolic hydroxyl group was modified during the oxidation.  相似文献   

11.
To explore the discriminatory power of matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) for detecting subtle differences in isogenic isolates, we tested isogenic strains of Staphylococcus aureus differing in their expression of resistance to methicillin or teicoplanin. More important changes in MALDI-TOF MS spectra were found with strains differing in methicillin than in teicoplanin resistance. In comparison, very minor or no changes were recorded in pulsed-field gel electrophoresis profiles or peptidoglycan muropeptide digest patterns of these strains, respectively. MALDI-TOF MS might be useful to detect subtle strain-specific differences in ionizable components released from bacterial surfaces and not from their peptidoglycan network.  相似文献   

12.
The use of peptide mass fingerprinting with matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) was demonstrated to identify and phenotypically characterize toluene-degrading bacteria via biomarkers of degradation and taxonomical classification. Pseudomonas putida F1, P. mendocina KR1, and Burkholderia sp. JS150 were grown on toluene, extracted, electrophoretically separated, and analyzed by MALDI-TOF MS. Catabolic enzymes were identified and results substantiated using tandem MS.  相似文献   

13.
The U.S. Environmental Protection Agency has developed method 1623 for simultaneous detection of Cryptosporidium oocysts and Giardia cysts in water. Method 1623 includes four major steps: filtration, immunomagnetic separation (IMS), fluorescent antibody (FA) staining and microscopic examination. It was noted that the recovery levels following IMS-FA and FA staining were high, averaging more than 92.0% and 89.0% for C. parvum oocysts and G. lamblia cysts, respectively. In contrast, when the filtration step was incorporated, the recovery level of C. parvum oocysts declined significantly to 18.1% in seeded tap water, while a relatively high recovery level of 77.2% for G. lamblia cysts could still be achieved. Further study indicated that the recovery level of C. parvum oocysts could be enhanced significantly when an appropriate amount of silica particles was added to a water sample. The recovery level of C. parvum oocysts was affected by particle size and concentration. The optimal silica particle size was determined to be within the range of 5-40 microm, and the corresponding optimal silica concentration was 1.42 g for 10-l tap water. When both G. lamblia cysts and C. parvum oocysts were spiked into the tap water sample containing the optimum amount of silica particles, the average recovery levels of oocysts and cysts were 82.7% and 75.4%, respectively. The results obtained clearly suggested that addition of an appropriate amount of silica particles could improve the recovery level of C. parvum oocysts significantly and yet there was no noticeable deleterious effect on the recovery level of G. lamblia cysts. Further study indicated that the rotation time in the IMS procedure using the Dynal GC-Combo IMS kit (which was recommended in method 1623) was important for G. lamblia cyst detection. In contrast, the recovery level of C. parvum oocysts was not affected by the rotation time. Furthermore, it was found that the recovery levels of C. parvum oocysts using methods 1622 and 1623 were quite close although different IMS kits were used in the two methods.  相似文献   

14.
The prevalence of pathogenic microorganisms in seawater can result in waterborne and food borne outbreaks. This study was performed to determine the effect of sunlight and salinity on the die-off of Cryptosporidium parvum. Cryptosporidium parvum oocysts, Escherichia coli, and MS2 coliphage were seeded into tap water and seawater samples and then exposed to sunlight. The die-off of C. parvum in seawater, as measured by infectivity, was greater under sunlight (-3.08 log10) than under dark conditions (-1.31 log10). While, no significant difference was recorded in the die-off of C. parvum, under dark conditions, in tap water as compared to seawater (P < 0.05), indicating that the synergistic effect of salinity and sunlight was responsible for the enhanced die-off in seawater. The die-off of MS2 coliphage and E. coli was greater than that observed for C. parvum under all tested conditions. This indicates that these microorganisms cannot serve as indicators for the presence of C. parvum oocysts in seawaters. The results of the study suggest that C. parvum can persist as infectious oocysts for a long time in seawater and can thus pose a serious hazard by direct and indirect contact with humans.  相似文献   

15.
The extracellular polysaccharides (ECPS) released by diatoms have significant roles in marine ecosystems and have potential applications including drug-discovery and biopharmaceutical precursors. In this study, matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) technology was used in the structural analysis of the ECPS released by Thalassiosira pseudonana (Bacillariophyta). Three different deproteinization methods, the Sevag method, the trichloroacetic acid (TCA) method, and the enzymolysis method, were compared in the purification of ECPS. Our results suggested that TCA was the best deproteinization method among the three methods for subsequent MALDI-TOF MS investigation because of its high ECPS yield, protein removal ability and reliable MALDI-TOF MS fingerprint. The degree of polymerization (d.p.) profiles, the molecular weight of the ECPS and the distribution pattern of the polymers with different molecular mass were described from the MALDI-TOF MS spectra. This work represents the whole-level composition of the ECPS released by the diatom and has improved our knowledge of the structural characterization of ECPS.  相似文献   

16.
The analysis of beef lipids is normally based on chromatographic techniques and/or gas chromatography in combination with mass spectrometry (GC/MS). Modern techniques of soft-ionization MS were so far scarcely used to investigate the intact lipids in muscle tissues of beef. The objective of the study was to investigate whether matrix-assisted laser desorption and ionization time-of-flight (MALDI-TOF) mass spectrometry and 31P nuclear magnetic resonance (NMR) spectroscopy are useful tools to study the intact lipid composition of beef. For the MALDI-TOF MS and 31P NMR investigations muscle samples were selected from a feeding experiment with German Simmental bulls fed different diets. Beside the triacylglycerols (TAGs), phosphatidylethanolamine (PE), phosphatidylcholine (PC) and phosphatidylinositol (PI) species the MALDI-TOF mass spectra of total muscle lipids gave also intense signals of cardiolipin (CL) species.The application of different matrix compounds, 2,5-dihydroxybenzoic acid (DHB) and 9-aminoacridine (9-AA), leads to completely different mass spectra: 9-AA is particularly useful for the detection of (polar) phospholipids, whereas apolar lipids, such as cholesterol and triacylglycerols, are exclusively detected if DHB is used. Finally, the quality of the negative ion mass spectra is much higher if 9-AA is used.  相似文献   

17.
Matrix-assisted laser desorption ionization–time of flight mass spectrometry (MALDI-TOF MS) is routinely used for bacterial identification. It would be highly beneficial to also be able to use the technology as a fast way to detect clinically relevant clones of bacterial species. However, studies to this aim have often had limited success. The methods used for data acquisition, processing and data interpretation are highly diverse amongst studies on MALDI-TOF MS sub-species typing. In addition to this, feasibility may depend on the bacterial species and strains investigated, making it difficult to determine what methods may or may not work. In our paper, we have reviewed recent research on MALDI-TOF MS typing of bacterial strains. Although we found a lot of variation amongst the methods used, there were approaches shared by multiple research groups. Multiple spectra of the same isolate were often combined before further analysis for strain distinction. Many groups used a protein extraction step to increase resolution in their MALDI-TOF MS results. Peaks at a high mass range were often excluded for data interpretation. Three groups have found ways to determine feasibility of MALDI-TOF MS typing for their set of strains at an early stage of their project.  相似文献   

18.
Matrix-assisted laser desorption and ionization time-of-flight (MALDI-TOF) mass spectrometry (MS) is increasingly used to characterize (phospho)lipids. However, quantitative MALDI data are often questioned because ion suppression may occur if mixtures are analyzed. Therefore, relative (but no absolute) data are normally derived from the MALDI mass spectra of lipid mixtures. We are particularly interested in the phosphatidylcholine/lysophosphatidylcholine (PC/LPC) ratio because it seems to represent a suitable measure of the inflammatory activity. In this study, different parameters affecting the achievable accuracy of the MALDI-TOF MS determination of the PC/LPC ratio are compared. It will be shown that particularly the applied laser fluence as well as the used solvents influence the accuracies. Using artificial lipid mixtures it will be demonstrated that the PC/LPC ratio can be determined with an accuracy of about ±10% making the MALDI assay comparable to established methods. Finally, it will be shown that the optimized conditions are also useful to determine the PC/LPC ratios in human seminal plasma.  相似文献   

19.
Kwon C  Lee S  Jung S 《Carbohydrate research》2011,(14):4071-2314
Low-molecular-weight (LMW) succinoglycans (monomers, dimers, and trimers) were isolated from Sinorhizobium meliloti 1021 and have been firstly investigated by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) using 2,4,6-trihydroxyacetophenone (THAP) as an optimal matrix in the negative ion mode. The main fractions of LMW succinoglycans contain molecules assembled of octasaccharide subunits. MALDI-TOF mass spectra of the LMW succinoglycan monomers, the dimers, and the trimers showed the daughter ions resulting from the losses of the terminal galactose residues at the reducing ends, clearly indicating that the galactosyl linkages are more labile than the other glucosyl linkages. Furthermore, the losses of the acetyl groups as substituents rather than the succinyl and pyruvyl ester linkages by prompt fragmentation primarily occurred during MALDI-TOF analysis, suggesting the greater instability of acetyl linkages compared to pyruvyl and succinyl linkages.  相似文献   

20.

Background

Whole-cell matrix–assisted laser desorption ionization time-of-flight (MALDI-TOF) mass spectrometry (MS) has been successfully applied for bacterial identification and typing of many pathogens. The fast and reliable qualities of MALDI-TOF MS make it suitable for clinical diagnostics. MALDI-TOF MS for the identification and cluster analysis of Streptococcus pyogenes, however, has not been reported. The goal of our study was to evaluate this approach for the rapid identification and typing of S. pyogenes.

Methods

65 S. pyogenes isolates were obtained from the hospital. The samples were prepared and MALDI-TOF MS measurements were conducted as previously reported. Identification of unknown spectra was performed via a pattern recognition algorithm with a reference spectra and a dendrogram was constructed using the statistical toolbox in Matlab 7.1 integrated in the MALDI Biotyper 2.0 software.

Results

For identification, 61 of 65 S. pyogenes isolates could be identified correctly by MALDI-TOF MS with BioType 2.0 when compared to biochemical identification (API Strep), with an accuracy of 93.85%. In clustering analysis, 44 of 65 isolates were in accordance with those established by M typing, with a matching rate of 67.69%. When only the M type prevalence in China was considered, 41 of 45 isolates were in agreement with M typing, with a matching rate of 91.1%.

Conclusions

It was here shown that MALDI-TOF MS with Soft Biotype 2.0 and its database could facilitate rapid identification of S. pyogenes. It may present an attractive alternative to traditional biochemical methods of identification. However, for classification, more isolates and advances in the MALDI-TOF MS technology are needed to improve accuracy.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏